CVE-2022-2502 (GCVE-0-2022-2502)
Vulnerability from cvelistv5 – Published: 2023-07-26 05:25 – Updated: 2025-03-05 18:47- CWE-20 - Improper Input Validation
| URL | Tags |
|---|---|
| https://publisher.hitachienergy.com/preview?Docum… | vendor-advisory |
| https://search.abb.com/library/Download.aspx?Docu… | x_transferred |
| Vendor | Product | Version | CPE status | |
|---|---|---|---|---|
| Hitachi Energy | RTU500 series |
Affected:
RTU500 series CMU Firmware version 13.3.1
Affected: RTU500 series CMU Firmware version 13.3.2 Unaffected: RTU500 series CMU Firmware version 13.3.3 Unaffected: RTU500 series CMU Firmware version 13.4.1 |
guessed |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T00:39:07.853Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://search.abb.com/library/Download.aspx?DocumentID=8DBD000121\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2022-2502",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-03-05T18:38:29.193487Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-03-05T18:47:06.707Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "RTU500 series",
"vendor": "Hitachi Energy",
"versions": [
{
"status": "affected",
"version": "RTU500 series CMU Firmware version 13.3.1"
},
{
"status": "affected",
"version": "RTU500 series CMU Firmware version 13.3.2"
},
{
"status": "unaffected",
"version": "RTU500 series CMU Firmware version 13.3.3"
},
{
"status": "unaffected",
"version": "RTU500 series CMU Firmware version 13.4.1"
}
]
}
],
"configurations": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "RTU500 series with HCI IEC 60870-5-104 and IEC 62351-5 configured and enabled.\u003cbr\u003e"
}
],
"value": "RTU500 series with HCI IEC 60870-5-104 and IEC 62351-5 configured and enabled."
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "A vulnerability exists in the HCI IEC 60870-5-104 function included in certain versions of the RTU500 series product. The vulnerability can only be exploited, if the HCI 60870-5-104 is configured with support for IEC 62351-5 and the CMU contains the license feature \u2018Advanced security\u2019 which must be ordered separately. If these preconditions are fulfilled, an attacker could exploit the vulnerability by sending a specially crafted message to the RTU500, causing the targeted RTU500 CMU to reboot. The vulnerability is caused by a missing input data validation which eventually if exploited causes an internal buffer to overflow in the HCI IEC 60870-5-104 function."
}
],
"value": "A vulnerability exists in the HCI IEC 60870-5-104 function included in certain versions of the RTU500 series product. The vulnerability can only be exploited, if the HCI 60870-5-104 is configured with support for IEC 62351-5 and the CMU contains the license feature \u2018Advanced security\u2019 which must be ordered separately. If these preconditions are fulfilled, an attacker could exploit the vulnerability by sending a specially crafted message to the RTU500, causing the targeted RTU500 CMU to reboot. The vulnerability is caused by a missing input data validation which eventually if exploited causes an internal buffer to overflow in the HCI IEC 60870-5-104 function."
}
],
"impacts": [
{
"capecId": "CAPEC-100",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-100 Overflow Buffers"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-20",
"description": "CWE-20 Improper Input Validation",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-09-24T15:29:49.528Z",
"orgId": "e383dce4-0c27-4495-91c4-0db157728d17",
"shortName": "Hitachi Energy"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://publisher.hitachienergy.com/preview?DocumentID=8DBD000121\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Update to CMU Firmware versions 13.3.3 or 13.4.1.\u003cbr\u003e"
}
],
"value": "Update to CMU Firmware versions 13.3.3 or 13.4.1."
}
],
"source": {
"discovery": "UNKNOWN"
},
"workarounds": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Disable the HCI IEC 60870-5-104 function or its IEC 62351-5 feature if it is not used. \u003cbr\u003e"
}
],
"value": "Disable the HCI IEC 60870-5-104 function or its IEC 62351-5 feature if it is not used."
}
],
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "e383dce4-0c27-4495-91c4-0db157728d17",
"assignerShortName": "Hitachi Energy",
"cveId": "CVE-2022-2502",
"datePublished": "2023-07-26T05:25:27.002Z",
"dateReserved": "2022-07-21T06:25:31.199Z",
"dateUpdated": "2025-03-05T18:47:06.707Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"epss": {
"cve": "CVE-2022-2502",
"date": "2026-11-24",
"epss": "0.00645",
"percentile": "0.51685"
},
"nvd": {
"cve": {
"affected": [
{
"affectedData": [
{
"defaultStatus": "unaffected",
"product": "RTU500 series",
"vendor": "Hitachi Energy",
"versions": [
{
"status": "affected",
"version": "RTU500 series CMU Firmware version 13.3.1"
},
{
"status": "affected",
"version": "RTU500 series CMU Firmware version 13.3.2"
},
{
"status": "unaffected",
"version": "RTU500 series CMU Firmware version 13.3.3"
},
{
"status": "unaffected",
"version": "RTU500 series CMU Firmware version 13.4.1"
}
]
}
],
"source": "cybersecurity@hitachienergy.com"
}
],
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:hitachienergy:rtu500_firmware:13.3.1:*:*:*:*:*:*:*",
"matchCriteriaId": "C444DE8E-5AC5-409B-8DA0-5C49A69076DD",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:hitachienergy:rtu500_firmware:13.3.2:*:*:*:*:*:*:*",
"matchCriteriaId": "4C55747C-E5DA-4444-B017-1994011A5EF7",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:hitachienergy:rtu500_firmware:13.3.3:*:*:*:*:*:*:*",
"matchCriteriaId": "0997C03B-21AC-4767-856C-79833FB378A8",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:hitachienergy:rtu500_firmware:13.4.1:*:*:*:*:*:*:*",
"matchCriteriaId": "C0763F03-C6C8-4104-9028-3CF265F289D5",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:hitachienergy:rtu500:-:*:*:*:*:*:*:*",
"matchCriteriaId": "DE94252D-03EE-451B-8322-B4DBC790C6E9",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability exists in the HCI IEC 60870-5-104 function included in certain versions of the RTU500 series product. The vulnerability can only be exploited, if the HCI 60870-5-104 is configured with support for IEC 62351-5 and the CMU contains the license feature \u2018Advanced security\u2019 which must be ordered separately. If these preconditions are fulfilled, an attacker could exploit the vulnerability by sending a specially crafted message to the RTU500, causing the targeted RTU500 CMU to reboot. The vulnerability is caused by a missing input data validation which eventually if exploited causes an internal buffer to overflow in the HCI IEC 60870-5-104 function."
},
{
"lang": "es",
"value": "Una vulnerabilidad existe en la funci\u00f3n HCI IEC 60870-5-104 incluida en ciertas versiones del producto de la serie RTU500. La vulnerabilidad solo puede ser explotada si la HCI 60870-5-104 est\u00e1 configurada con soporte para IEC 62351-5 y la CMU contiene la caracter\u00edstica de licencia \u2019Advanced security\u2019, que debe solicitarse por separado. Si se cumplen estas precondiciones, un atacante podr\u00eda explotar la vulnerabilidad enviando un mensaje especialmente dise\u00f1ado a la RTU500, causando que la CMU de la RTU500 objetivo se reinicie. La vulnerabilidad es causada por una validaci\u00f3n de datos de entrada faltante que, si se explota, eventualmente causa un desbordamiento de b\u00fafer interno en la funci\u00f3n HCI IEC 60870-5-104."
}
],
"id": "CVE-2022-2502",
"lastModified": "2026-11-10T12:10:00.177",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 3.6,
"source": "cybersecurity@hitachienergy.com",
"type": "Secondary"
},
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 3.6,
"source": "nvd@nist.gov",
"type": "Primary"
}
],
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2022-2502",
"options": [
{
"exploitation": "none"
},
{
"automatable": "yes"
},
{
"technicalImpact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-03-05T18:38:29.193487Z",
"version": "2.0.3"
}
}
]
},
"published": "2023-07-26T06:15:09.760",
"references": [
{
"source": "cybersecurity@hitachienergy.com",
"url": "https://publisher.hitachienergy.com/preview?DocumentID=8DBD000121\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"url": "https://search.abb.com/library/Download.aspx?DocumentID=8DBD000121\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
}
],
"sourceIdentifier": "cybersecurity@hitachienergy.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-20"
}
],
"source": "cybersecurity@hitachienergy.com",
"type": "Secondary"
},
{
"description": [
{
"lang": "en",
"value": "CWE-20"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
},
"redhat_vex": {
"current_release_date": "2025-05-29T03:08:25+00:00",
"cve": "CVE-2022-2502",
"id": "CVE-2022-2502",
"initial_release_date": "2022-01-01T00:00:00+00:00",
"product_status:known_not_affected": "1",
"source": "Red Hat CSAF VEX",
"status": "final",
"title": "CVE-2022-2502",
"url": "https://security.access.redhat.com/data/csaf/v2/vex/2022/cve-2022-2502.json",
"version": "3"
},
"vulnrichment": {
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T00:39:07.853Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://search.abb.com/library/Download.aspx?DocumentID=8DBD000121\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2022-2502",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-03-05T18:38:29.193487Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-03-05T18:38:31.016Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "RTU500 series",
"vendor": "Hitachi Energy",
"versions": [
{
"status": "affected",
"version": "RTU500 series CMU Firmware version 13.3.1"
},
{
"status": "affected",
"version": "RTU500 series CMU Firmware version 13.3.2"
},
{
"status": "unaffected",
"version": "RTU500 series CMU Firmware version 13.3.3"
},
{
"status": "unaffected",
"version": "RTU500 series CMU Firmware version 13.4.1"
}
]
}
],
"configurations": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "RTU500 series with HCI IEC 60870-5-104 and IEC 62351-5 configured and enabled.\u003cbr\u003e"
}
],
"value": "RTU500 series with HCI IEC 60870-5-104 and IEC 62351-5 configured and enabled."
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "A vulnerability exists in the HCI IEC 60870-5-104 function included in certain versions of the RTU500 series product. The vulnerability can only be exploited, if the HCI 60870-5-104 is configured with support for IEC 62351-5 and the CMU contains the license feature \u2018Advanced security\u2019 which must be ordered separately. If these preconditions are fulfilled, an attacker could exploit the vulnerability by sending a specially crafted message to the RTU500, causing the targeted RTU500 CMU to reboot. The vulnerability is caused by a missing input data validation which eventually if exploited causes an internal buffer to overflow in the HCI IEC 60870-5-104 function."
}
],
"value": "A vulnerability exists in the HCI IEC 60870-5-104 function included in certain versions of the RTU500 series product. The vulnerability can only be exploited, if the HCI 60870-5-104 is configured with support for IEC 62351-5 and the CMU contains the license feature \u2018Advanced security\u2019 which must be ordered separately. If these preconditions are fulfilled, an attacker could exploit the vulnerability by sending a specially crafted message to the RTU500, causing the targeted RTU500 CMU to reboot. The vulnerability is caused by a missing input data validation which eventually if exploited causes an internal buffer to overflow in the HCI IEC 60870-5-104 function."
}
],
"impacts": [
{
"capecId": "CAPEC-100",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-100 Overflow Buffers"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-20",
"description": "CWE-20 Improper Input Validation",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-09-24T15:29:49.528Z",
"orgId": "e383dce4-0c27-4495-91c4-0db157728d17",
"shortName": "Hitachi Energy"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://publisher.hitachienergy.com/preview?DocumentID=8DBD000121\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Update to CMU Firmware versions 13.3.3 or 13.4.1.\u003cbr\u003e"
}
],
"value": "Update to CMU Firmware versions 13.3.3 or 13.4.1."
}
],
"source": {
"discovery": "UNKNOWN"
},
"workarounds": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Disable the HCI IEC 60870-5-104 function or its IEC 62351-5 feature if it is not used. \u003cbr\u003e"
}
],
"value": "Disable the HCI IEC 60870-5-104 function or its IEC 62351-5 feature if it is not used."
}
],
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "e383dce4-0c27-4495-91c4-0db157728d17",
"assignerShortName": "Hitachi Energy",
"cveId": "CVE-2022-2502",
"datePublished": "2023-07-26T05:25:27.002Z",
"dateReserved": "2022-07-21T06:25:31.199Z",
"dateUpdated": "2025-03-05T18:47:06.707Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
}
}
Solutions
Workarounds
Configurations
Drag nodes to arrange them. Double-click a related vulnerability to open it, or a source to visit its link. The Physics button on the left tunes the layout and the simulation; the legend at the bottom left hides or shows nodes by kind and by sighting type.
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Vulnerability timeline
Sightings and recorded dates, grouped by day · UTC
How durations are calculated
Following the VTEM framework (Black Hat USA 2015), time to patch starts when the vendor or a coordinator was informed, total time to patch at discovery, and disclosure to patch at public disclosure; vendor response time runs from the report to its acknowledgement. Time to exploit and time unpatched start at the earliest discovery or report, falling back to public disclosure. Unpatched time ends at the first recorded patch, or the calculation time when no patch is recorded. Exploitation to patch shows the interval between those two events; a published proof of concept is a public exploit, not exploitation. The method is described in a publication.
Each result shows its source dates. A negative interval means the end event came first; when date-only inputs leave the order open, the result says so. Date-only inputs are approximate. The earliest evidence wins: KEV report dates and sightings are labelled as such. Records describing another vulnerability are listed but never calculated from, and a PoC alone does not establish exploitation. Missing patch evidence does not prove that no patch exists. Filters below change the event list only.
Loading timeline…
The approach is described in our paper Mapping CVEs to MITRE ATT&CK Techniques: A Curated Gold-Set Classifier and the Limits of LLM-Assisted Label Expansion.
Browse all ATT&CK techniques and the vulnerabilities related to each.
Related by attack behaviour
Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.