CVE-2022-1018 (GCVE-0-2022-1018)

Vulnerability from cvelistv5 – Published: 2022-04-01 22:17 – Updated: 2025-04-16 16:32
VLAI
Title
ICSA-22-088-01 Rockwell Automation ISaGRAF
Summary
When opening a malicious solution file provided by an attacker, the application suffers from an XML external entity vulnerability due to an unsafe call within a dynamic link library file. An attacker could exploit this to pass data from local files to a remote web server, leading to a loss of confidentiality.
SSVC
Exploitation: none Automatable: no Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2025-04-16 15:54 UTC
CWE
  • CWE-611 - Improper Restriction of XML External Entity Reference ('XXE')
Assigner
icscert CNA under the icscert root
CNA scorecard B 75/100 over 337 records in the last 180 days details
References
Impacted products
Date Public
2022-03-29 00:00
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T23:47:42.899Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-088-01"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2022-1018",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-04-16T15:54:59.168246Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-04-16T16:32:28.157Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Connected Component Workbench",
          "vendor": "Rockwell Automation",
          "versions": [
            {
              "lessThan": "12",
              "status": "affected",
              "version": "All",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "ISaGRAF",
          "vendor": "Rockwell Automation",
          "versions": [
            {
              "lessThan": "6.6.9",
              "status": "affected",
              "version": "All",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "Safety Instrumented Systems Workstation",
          "vendor": "Rockwell Automation",
          "versions": [
            {
              "lessThan": "1.1",
              "status": "affected",
              "version": "All",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "value": "kimiya of Trend Micro\u2019s Zero Day Initiative reported this vulnerability to CISA."
        }
      ],
      "datePublic": "2022-03-29T00:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "value": "When opening a malicious solution file provided by an attacker, the application suffers from an XML external entity vulnerability due to an unsafe call within a dynamic link library file. An attacker could exploit this to pass data from local files to a remote web server, leading to a loss of confidentiality."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "NONE",
            "baseScore": 5.5,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:N",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-611",
              "description": "CWE-611 Improper Restriction of XML External Entity Reference (\u0027XXE\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-04-01T22:17:24.000Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-088-01"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "value": "Rockwell Automation encourages users to update to the available software revisions below:\n\nConnected Component Workbench: Update to v13.00\nISaGRAF Workbench: For now, use mitigations listed until a patch is released. More mitigation actions are planned.\nSafety Instrumented Systems Workstation: Update to v1.2"
        }
      ],
      "source": {
        "advisory": "ICSA-22-088-01",
        "discovery": "EXTERNAL"
      },
      "title": "ICSA-22-088-01 Rockwell Automation ISaGRAF",
      "workarounds": [
        {
          "lang": "en",
          "value": "If an upgrade is not possible or available, users should apply the following mitigations:\n\nRun Connected Components Workbench as a User, not as an Administrator, to minimize the impact of malicious code on the infected system.\nDo not open untrusted files with Connected Component Workbench, ISaGRAF, SISW. Employ training and awareness programs to educate users on the warning signs of a phishing or social engineering attack.\nUse Microsoft AppLocker or other similar allow list application to help mitigate risk. Information on using AppLocker with Rockwell Automation products is available at KnowledgeBase Article QA17329\nEnsure the least-privilege user principle is followed, and user/service account access to shared resources (such as a database) is only granted with a minimum number of rights as needed."
        }
      ],
      "x_generator": {
        "engine": "Vulnogram 0.0.9"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "DATE_PUBLIC": "2022-03-29T17:00:00.000Z",
          "ID": "CVE-2022-1018",
          "STATE": "PUBLIC",
          "TITLE": "ICSA-22-088-01 Rockwell Automation ISaGRAF"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Connected Component Workbench",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "All",
                            "version_value": "12"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "ISaGRAF",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "All",
                            "version_value": "6.6.9"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Safety Instrumented Systems Workstation",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "All",
                            "version_value": "1.1"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Rockwell Automation"
              }
            ]
          }
        },
        "credit": [
          {
            "lang": "eng",
            "value": "kimiya of Trend Micro\u2019s Zero Day Initiative reported this vulnerability to CISA."
          }
        ],
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "When opening a malicious solution file provided by an attacker, the application suffers from an XML external entity vulnerability due to an unsafe call within a dynamic link library file. An attacker could exploit this to pass data from local files to a remote web server, leading to a loss of confidentiality."
            }
          ]
        },
        "generator": {
          "engine": "Vulnogram 0.0.9"
        },
        "impact": {
          "cvss": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "NONE",
            "baseScore": 5.5,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:N",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-611 Improper Restriction of XML External Entity Reference (\u0027XXE\u0027)"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-088-01",
              "refsource": "MISC",
              "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-088-01"
            }
          ]
        },
        "solution": [
          {
            "lang": "en",
            "value": "Rockwell Automation encourages users to update to the available software revisions below:\n\nConnected Component Workbench: Update to v13.00\nISaGRAF Workbench: For now, use mitigations listed until a patch is released. More mitigation actions are planned.\nSafety Instrumented Systems Workstation: Update to v1.2"
          }
        ],
        "source": {
          "advisory": "ICSA-22-088-01",
          "discovery": "EXTERNAL"
        },
        "work_around": [
          {
            "lang": "en",
            "value": "If an upgrade is not possible or available, users should apply the following mitigations:\n\nRun Connected Components Workbench as a User, not as an Administrator, to minimize the impact of malicious code on the infected system.\nDo not open untrusted files with Connected Component Workbench, ISaGRAF, SISW. Employ training and awareness programs to educate users on the warning signs of a phishing or social engineering attack.\nUse Microsoft AppLocker or other similar allow list application to help mitigate risk. Information on using AppLocker with Rockwell Automation products is available at KnowledgeBase Article QA17329\nEnsure the least-privilege user principle is followed, and user/service account access to shared resources (such as a database) is only granted with a minimum number of rights as needed."
          }
        ]
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2022-1018",
    "datePublished": "2022-04-01T22:17:24.599Z",
    "dateReserved": "2022-03-17T00:00:00.000Z",
    "dateUpdated": "2025-04-16T16:32:28.157Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "epss": {
      "cve": "CVE-2022-1018",
      "date": "2026-11-18",
      "epss": "0.02155",
      "percentile": "0.82534"
    },
    "nvd": {
      "cve": {
        "affected": [
          {
            "affectedData": [
              {
                "product": "Connected Component Workbench",
                "vendor": "Rockwell Automation",
                "versions": [
                  {
                    "lessThan": "12",
                    "status": "affected",
                    "version": "All",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "product": "ISaGRAF",
                "vendor": "Rockwell Automation",
                "versions": [
                  {
                    "lessThan": "6.6.9",
                    "status": "affected",
                    "version": "All",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "product": "Safety Instrumented Systems Workstation",
                "vendor": "Rockwell Automation",
                "versions": [
                  {
                    "lessThan": "1.1",
                    "status": "affected",
                    "version": "All",
                    "versionType": "custom"
                  }
                ]
              }
            ],
            "source": "ics-cert@hq.dhs.gov"
          }
        ],
        "configurations": [
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:a:rockwellautomation:connected_components_workbench:*:*:*:*:-:*:*:*",
                    "matchCriteriaId": "06DE97E4-74B3-4CC2-99C4-7EB0E38D5F34",
                    "versionEndIncluding": "12.0",
                    "vulnerable": true
                  },
                  {
                    "criteria": "cpe:2.3:a:rockwellautomation:isagraf:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "6B871240-C4D4-478D-9A6A-378A082B5365",
                    "versionEndIncluding": "6.6.9",
                    "vulnerable": true
                  },
                  {
                    "criteria": "cpe:2.3:o:rockwellautomation:safety_instrumented_systems_workstation:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "C576D1B7-D890-4172-9500-E8FFF3366E4B",
                    "versionEndIncluding": "1.1",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ]
          }
        ],
        "cveTags": [],
        "descriptions": [
          {
            "lang": "en",
            "value": "When opening a malicious solution file provided by an attacker, the application suffers from an XML external entity vulnerability due to an unsafe call within a dynamic link library file. An attacker could exploit this to pass data from local files to a remote web server, leading to a loss of confidentiality."
          },
          {
            "lang": "es",
            "value": "Cuando es abierto un archivo de soluci\u00f3n malicioso proporcionado por un atacante, la aplicaci\u00f3n sufre una vulnerabilidad de tipo XML external entity debido a una llamada no segura dentro de un archivo de biblioteca de enlace din\u00e1mico. Un atacante podr\u00eda aprovechar esto para pasar datos de archivos locales a un servidor web remoto, conllevando a una p\u00e9rdida de confidencialidad"
          }
        ],
        "id": "CVE-2022-1018",
        "lastModified": "2026-06-17T04:21:39.187",
        "metrics": {
          "cvssMetricV2": [
            {
              "acInsufInfo": false,
              "baseSeverity": "MEDIUM",
              "cvssData": {
                "accessComplexity": "MEDIUM",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "availabilityImpact": "NONE",
                "baseScore": 4.3,
                "confidentialityImpact": "PARTIAL",
                "integrityImpact": "NONE",
                "vectorString": "AV:N/AC:M/Au:N/C:P/I:N/A:N",
                "version": "2.0"
              },
              "exploitabilityScore": 8.6,
              "impactScore": 2.9,
              "obtainAllPrivilege": false,
              "obtainOtherPrivilege": false,
              "obtainUserPrivilege": false,
              "source": "nvd@nist.gov",
              "type": "Primary",
              "userInteractionRequired": true
            }
          ],
          "cvssMetricV31": [
            {
              "cvssData": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "NONE",
                "baseScore": 5.5,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:N",
                "version": "3.1"
              },
              "exploitabilityScore": 1.8,
              "impactScore": 3.6,
              "source": "ics-cert@hq.dhs.gov",
              "type": "Secondary"
            },
            {
              "cvssData": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "NONE",
                "baseScore": 5.5,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:N",
                "version": "3.1"
              },
              "exploitabilityScore": 1.8,
              "impactScore": 3.6,
              "source": "nvd@nist.gov",
              "type": "Primary"
            }
          ],
          "ssvcV203": [
            {
              "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "ssvcData": {
                "id": "CVE-2022-1018",
                "options": [
                  {
                    "exploitation": "none"
                  },
                  {
                    "automatable": "no"
                  },
                  {
                    "technicalImpact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-04-16T15:54:59.168246Z",
                "version": "2.0.3"
              }
            }
          ]
        },
        "published": "2022-04-01T23:15:12.177",
        "references": [
          {
            "source": "ics-cert@hq.dhs.gov",
            "tags": [
              "Mitigation",
              "Patch",
              "Third Party Advisory",
              "US Government Resource"
            ],
            "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-088-01"
          },
          {
            "source": "af854a3a-2127-422b-91ae-364da2661108",
            "tags": [
              "Mitigation",
              "Patch",
              "Third Party Advisory",
              "US Government Resource"
            ],
            "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-088-01"
          }
        ],
        "sourceIdentifier": "ics-cert@hq.dhs.gov",
        "vulnStatus": "Modified",
        "weaknesses": [
          {
            "description": [
              {
                "lang": "en",
                "value": "CWE-611"
              }
            ],
            "source": "ics-cert@hq.dhs.gov",
            "type": "Secondary"
          },
          {
            "description": [
              {
                "lang": "en",
                "value": "CWE-611"
              }
            ],
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ]
      }
    },
    "redhat_vex": {
      "current_release_date": "2025-05-29T02:34:07+00:00",
      "cve": "CVE-2022-1018",
      "id": "CVE-2022-1018",
      "initial_release_date": "2022-03-29T00:00:00+00:00",
      "product_status:known_not_affected": "1",
      "source": "Red Hat CSAF VEX",
      "status": "final",
      "title": "ICSA-22-088-01 Rockwell Automation ISaGRAF",
      "url": "https://security.access.redhat.com/data/csaf/v2/vex/2022/cve-2022-1018.json",
      "version": "3"
    },
    "vulnrichment": {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T23:47:42.899Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-088-01"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2022-1018",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-04-16T15:54:59.168246Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-04-16T15:55:01.616Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "Connected Component Workbench",
              "vendor": "Rockwell Automation",
              "versions": [
                {
                  "lessThan": "12",
                  "status": "affected",
                  "version": "All",
                  "versionType": "custom"
                }
              ]
            },
            {
              "product": "ISaGRAF",
              "vendor": "Rockwell Automation",
              "versions": [
                {
                  "lessThan": "6.6.9",
                  "status": "affected",
                  "version": "All",
                  "versionType": "custom"
                }
              ]
            },
            {
              "product": "Safety Instrumented Systems Workstation",
              "vendor": "Rockwell Automation",
              "versions": [
                {
                  "lessThan": "1.1",
                  "status": "affected",
                  "version": "All",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "value": "kimiya of Trend Micro\u2019s Zero Day Initiative reported this vulnerability to CISA."
            }
          ],
          "datePublic": "2022-03-29T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "When opening a malicious solution file provided by an attacker, the application suffers from an XML external entity vulnerability due to an unsafe call within a dynamic link library file. An attacker could exploit this to pass data from local files to a remote web server, leading to a loss of confidentiality."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "NONE",
                "baseScore": 5.5,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:N",
                "version": "3.1"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-611",
                  "description": "CWE-611 Improper Restriction of XML External Entity Reference (\u0027XXE\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2022-04-01T22:17:24.000Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-088-01"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "value": "Rockwell Automation encourages users to update to the available software revisions below:\n\nConnected Component Workbench: Update to v13.00\nISaGRAF Workbench: For now, use mitigations listed until a patch is released. More mitigation actions are planned.\nSafety Instrumented Systems Workstation: Update to v1.2"
            }
          ],
          "source": {
            "advisory": "ICSA-22-088-01",
            "discovery": "EXTERNAL"
          },
          "title": "ICSA-22-088-01 Rockwell Automation ISaGRAF",
          "workarounds": [
            {
              "lang": "en",
              "value": "If an upgrade is not possible or available, users should apply the following mitigations:\n\nRun Connected Components Workbench as a User, not as an Administrator, to minimize the impact of malicious code on the infected system.\nDo not open untrusted files with Connected Component Workbench, ISaGRAF, SISW. Employ training and awareness programs to educate users on the warning signs of a phishing or social engineering attack.\nUse Microsoft AppLocker or other similar allow list application to help mitigate risk. Information on using AppLocker with Rockwell Automation products is available at KnowledgeBase Article QA17329\nEnsure the least-privilege user principle is followed, and user/service account access to shared resources (such as a database) is only granted with a minimum number of rights as needed."
            }
          ],
          "x_generator": {
            "engine": "Vulnogram 0.0.9"
          },
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "ics-cert@hq.dhs.gov",
              "DATE_PUBLIC": "2022-03-29T17:00:00.000Z",
              "ID": "CVE-2022-1018",
              "STATE": "PUBLIC",
              "TITLE": "ICSA-22-088-01 Rockwell Automation ISaGRAF"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "Connected Component Workbench",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003c",
                                "version_name": "All",
                                "version_value": "12"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "ISaGRAF",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003c",
                                "version_name": "All",
                                "version_value": "6.6.9"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "Safety Instrumented Systems Workstation",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003c",
                                "version_name": "All",
                                "version_value": "1.1"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "Rockwell Automation"
                  }
                ]
              }
            },
            "credit": [
              {
                "lang": "eng",
                "value": "kimiya of Trend Micro\u2019s Zero Day Initiative reported this vulnerability to CISA."
              }
            ],
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "When opening a malicious solution file provided by an attacker, the application suffers from an XML external entity vulnerability due to an unsafe call within a dynamic link library file. An attacker could exploit this to pass data from local files to a remote web server, leading to a loss of confidentiality."
                }
              ]
            },
            "generator": {
              "engine": "Vulnogram 0.0.9"
            },
            "impact": {
              "cvss": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "NONE",
                "baseScore": 5.5,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:N",
                "version": "3.1"
              }
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-611 Improper Restriction of XML External Entity Reference (\u0027XXE\u0027)"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-088-01",
                  "refsource": "MISC",
                  "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-088-01"
                }
              ]
            },
            "solution": [
              {
                "lang": "en",
                "value": "Rockwell Automation encourages users to update to the available software revisions below:\n\nConnected Component Workbench: Update to v13.00\nISaGRAF Workbench: For now, use mitigations listed until a patch is released. More mitigation actions are planned.\nSafety Instrumented Systems Workstation: Update to v1.2"
              }
            ],
            "source": {
              "advisory": "ICSA-22-088-01",
              "discovery": "EXTERNAL"
            },
            "work_around": [
              {
                "lang": "en",
                "value": "If an upgrade is not possible or available, users should apply the following mitigations:\n\nRun Connected Components Workbench as a User, not as an Administrator, to minimize the impact of malicious code on the infected system.\nDo not open untrusted files with Connected Component Workbench, ISaGRAF, SISW. Employ training and awareness programs to educate users on the warning signs of a phishing or social engineering attack.\nUse Microsoft AppLocker or other similar allow list application to help mitigate risk. Information on using AppLocker with Rockwell Automation products is available at KnowledgeBase Article QA17329\nEnsure the least-privilege user principle is followed, and user/service account access to shared resources (such as a database) is only granted with a minimum number of rights as needed."
              }
            ]
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2022-1018",
        "datePublished": "2022-04-01T22:17:24.599Z",
        "dateReserved": "2022-03-17T00:00:00.000Z",
        "dateUpdated": "2025-04-16T16:32:28.157Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }
  }
}


Solutions

CNA · icscert
Rockwell Automation encourages users to update to the available software revisions below: Connected Component Workbench: Update to v13.00 ISaGRAF Workbench: For now, use mitigations listed until a patch is released. More mitigation actions are planned. Safety Instrumented Systems Workstation: Update to v1.2

Workarounds

CNA · icscert
If an upgrade is not possible or available, users should apply the following mitigations: Run Connected Components Workbench as a User, not as an Administrator, to minimize the impact of malicious code on the infected system. Do not open untrusted files with Connected Component Workbench, ISaGRAF, SISW. Employ training and awareness programs to educate users on the warning signs of a phishing or social engineering attack. Use Microsoft AppLocker or other similar allow list application to help mitigate risk. Information on using AppLocker with Rockwell Automation products is available at KnowledgeBase Article QA17329 Ensure the least-privilege user principle is followed, and user/service account access to shared resources (such as a database) is only granted with a minimum number of rights as needed.

Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Drag nodes to arrange them. Double-click a related vulnerability to open it, or a source to visit its link. The Physics button on the left tunes the layout and the simulation; the legend at the bottom left hides or shows nodes by kind and by sighting type.

Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Vulnerability timeline

Sightings and recorded dates, grouped by day · UTC

JSON
How durations are calculated

Following the VTEM framework (Black Hat USA 2015), time to patch starts when the vendor or a coordinator was informed, total time to patch at discovery, and disclosure to patch at public disclosure; vendor response time runs from the report to its acknowledgement. Time to exploit and time unpatched start at the earliest discovery or report, falling back to public disclosure. Unpatched time ends at the first recorded patch, or the calculation time when no patch is recorded. Exploitation to patch shows the interval between those two events; a published proof of concept is a public exploit, not exploitation.

Each result shows its source dates. A negative interval means the end event came first; when date-only inputs leave the order open, the result says so. Date-only inputs are approximate. The earliest evidence wins: KEV report dates and sightings are labelled as such. Records describing another vulnerability are listed but never calculated from, and a PoC alone does not establish exploitation. Missing patch evidence does not prove that no patch exists. Filters below change the event list only.

Events included in the timeline

Loading timeline…


    Loading…

    Loading…

    Loading…

    Related by attack behaviour

    Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.