CVE-2021-36278 (GCVE-0-2021-36278)
Vulnerability from cvelistv5 – Published: 2021-08-16 22:00 – Updated: 2024-09-17 03:03
VLAI
EPSS
VEX
Summary
Dell EMC PowerScale OneFS versions 8.2.x, 9.1.0.x, and 9.1.1.1 contain a sensitive information exposure vulnerability in log files. A local malicious user with ISI_PRIV_LOGIN_SSH, ISI_PRIV_LOGIN_CONSOLE, or ISI_PRIV_SYS_SUPPORT privileges may exploit this vulnerability to access sensitive information. If any third-party consumes those logs, the same sensitive information is available to those systems as well.
Severity
8.1 (High)
CWE
- CWE-532 - Information Exposure Through Log Files
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://www.dell.com/support/kbdoc/000190408 | x_refsource_MISC |
Impacted products
1 product
| Vendor | Product | Version | CPE status | |
|---|---|---|---|---|
| Dell | PowerScale OneFS |
Affected:
8.2.x, 9.1.0.x
|
guessed |
Date Public
2021-08-10 00:00
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T00:54:51.071Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.dell.com/support/kbdoc/000190408"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "PowerScale OneFS",
"vendor": "Dell",
"versions": [
{
"status": "affected",
"version": "8.2.x, 9.1.0.x"
}
]
}
],
"datePublic": "2021-08-10T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "Dell EMC PowerScale OneFS versions 8.2.x, 9.1.0.x, and 9.1.1.1 contain a sensitive information exposure vulnerability in log files. A local malicious user with ISI_PRIV_LOGIN_SSH, ISI_PRIV_LOGIN_CONSOLE, or ISI_PRIV_SYS_SUPPORT privileges may exploit this vulnerability to access sensitive information. If any third-party consumes those logs, the same sensitive information is available to those systems as well."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.1,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-532",
"description": "CWE-532: Information Exposure Through Log Files",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-05-11T15:55:09.000Z",
"orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"shortName": "dell"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.dell.com/support/kbdoc/000190408"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "secure@dell.com",
"DATE_PUBLIC": "2021-08-10",
"ID": "CVE-2021-36278",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "PowerScale OneFS",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "8.2.x, 9.1.0.x"
}
]
}
}
]
},
"vendor_name": "Dell"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Dell EMC PowerScale OneFS versions 8.2.x, 9.1.0.x, and 9.1.1.1 contain a sensitive information exposure vulnerability in log files. A local malicious user with ISI_PRIV_LOGIN_SSH, ISI_PRIV_LOGIN_CONSOLE, or ISI_PRIV_SYS_SUPPORT privileges may exploit this vulnerability to access sensitive information. If any third-party consumes those logs, the same sensitive information is available to those systems as well."
}
]
},
"impact": {
"cvss": {
"baseScore": 8.1,
"baseSeverity": "High",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-532: Information Exposure Through Log Files"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.dell.com/support/kbdoc/000190408",
"refsource": "MISC",
"url": "https://www.dell.com/support/kbdoc/000190408"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"assignerShortName": "dell",
"cveId": "CVE-2021-36278",
"datePublished": "2021-08-16T22:00:29.902Z",
"dateReserved": "2021-07-08T00:00:00.000Z",
"dateUpdated": "2024-09-17T03:03:09.906Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"epss": {
"cve": "CVE-2021-36278",
"date": "2026-10-22",
"epss": "0.00565",
"percentile": "0.46168"
},
"nvd": {
"cve": {
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:dell:emc_powerscale_onefs:*:*:*:*:*:*:*:*",
"matchCriteriaId": "02FBC847-4898-4532-9046-CEBDED1838C8",
"versionEndIncluding": "8.2.2",
"versionStartIncluding": "8.2.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:dell:emc_powerscale_onefs:*:*:*:*:*:*:*:*",
"matchCriteriaId": "0FD575EC-3EEC-4E99-85F7-695AAD5691ED",
"versionEndIncluding": "9.1.0",
"versionStartIncluding": "9.0.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:dell:emc_powerscale_onefs:9.1.1.1:*:*:*:*:*:*:*",
"matchCriteriaId": "354AE2BD-1EDD-44F0-838B-46DF45AB5718",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:dell:emc_powerscale_onefs:9.2.0:*:*:*:*:*:*:*",
"matchCriteriaId": "F05788CE-CA4C-44FF-87FB-69725F95FB23",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "Dell EMC PowerScale OneFS versions 8.2.x, 9.1.0.x, and 9.1.1.1 contain a sensitive information exposure vulnerability in log files. A local malicious user with ISI_PRIV_LOGIN_SSH, ISI_PRIV_LOGIN_CONSOLE, or ISI_PRIV_SYS_SUPPORT privileges may exploit this vulnerability to access sensitive information. If any third-party consumes those logs, the same sensitive information is available to those systems as well."
},
{
"lang": "es",
"value": "Las versiones 8.2.x, 9.1.0.x y 9.1.1.1 de Dell EMC PowerScale OneFS contienen una vulnerabilidad de exposici\u00f3n de informaci\u00f3n sensible en los archivos de registro. Un usuario local malintencionado con privilegios ISI_PRIV_LOGIN_SSH, ISI_PRIV_LOGIN_CONSOLE o ISI_PRIV_SYS_SUPPORT puede aprovechar esta vulnerabilidad para acceder a informaci\u00f3n sensible. Si alg\u00fan tercero consume esos registros, la misma informaci\u00f3n sensible estar\u00e1 disponible tambi\u00e9n para esos sistemas"
}
],
"id": "CVE-2021-36278",
"lastModified": "2024-11-21T06:13:24.683",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "LOW",
"cvssData": {
"accessComplexity": "LOW",
"accessVector": "LOCAL",
"authentication": "NONE",
"availabilityImpact": "NONE",
"baseScore": 2.1,
"confidentialityImpact": "PARTIAL",
"integrityImpact": "NONE",
"vectorString": "AV:L/AC:L/Au:N/C:P/I:N/A:N",
"version": "2.0"
},
"exploitabilityScore": 3.9,
"impactScore": 2.9,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": false
}
],
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "HIGH",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.1,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 2.2,
"impactScore": 5.9,
"source": "security_alert@emc.com",
"type": "Secondary"
},
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "NONE",
"baseScore": 5.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
},
"exploitabilityScore": 1.8,
"impactScore": 3.6,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2021-08-16T22:15:07.687",
"references": [
{
"source": "security_alert@emc.com",
"tags": [
"Patch",
"Vendor Advisory"
],
"url": "https://www.dell.com/support/kbdoc/000190408"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Patch",
"Vendor Advisory"
],
"url": "https://www.dell.com/support/kbdoc/000190408"
}
],
"sourceIdentifier": "security_alert@emc.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-532"
}
],
"source": "security_alert@emc.com",
"type": "Secondary"
},
{
"description": [
{
"lang": "en",
"value": "CWE-532"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
},
"redhat_vex": {
"current_release_date": "2026-03-27T13:49:30+00:00",
"cve": "CVE-2021-36278",
"id": "CVE-2021-36278",
"initial_release_date": "2021-08-10T00:00:00+00:00",
"product_status:known_not_affected": "1",
"source": "Red Hat CSAF VEX",
"status": "final",
"title": "CVE-2021-36278",
"url": "https://security.access.redhat.com/data/csaf/v2/vex/2021/cve-2021-36278.json",
"version": "3"
}
}
}
Loading…
Loading…
Drag nodes to arrange them. Double-click a related vulnerability to open it, or a source to visit its link. The Physics button on the left tunes the layout and the simulation; the legend at the bottom left hides or shows nodes by kind and by sighting type.
Experimental. This forecast is provided for visualization only and may change without notice. Do not use it for operational decisions.
Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Vulnerability timeline
Sightings and recorded dates, grouped by day · UTC
Loading timeline…
Loading…
Loading…
The MITRE ATT&CK techniques below are AI-generated suggestions, inferred from the description of the
vulnerability by the CIRCL/vulnerability-attack-technique-classification-roberta-base
model, served locally by ML-Gateway.
They have not been verified by an analyst and are provided for guidance only.
The approach is described in our paper Mapping CVEs to MITRE ATT&CK Techniques: A Curated Gold-Set Classifier and the Limits of LLM-Assisted Label Expansion.
Browse all ATT&CK techniques and the vulnerabilities related to each.
The approach is described in our paper Mapping CVEs to MITRE ATT&CK Techniques: A Curated Gold-Set Classifier and the Limits of LLM-Assisted Label Expansion.
Browse all ATT&CK techniques and the vulnerabilities related to each.
Loading…
Related by attack behaviour
Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.