CVE-2021-33023 (GCVE-0-2021-33023)

Vulnerability from cvelistv5 – Published: 2021-10-18 12:41 – Updated: 2024-09-17 03:49
VLAI
Title
Advantech WebAccess
Summary
Advantech WebAccess versions 9.02 and prior are vulnerable to a heap-based buffer overflow, which may allow an attacker to remotely execute code.
CWE
  • CWE-122 - HEAP-BASED BUFFER OVERFLOW CWE-122
Assigner
icscert CNA under the icscert root
CNA scorecard B 75/100 over 343 records in the last 180 days details
References
Impacted products
Vendor Product Version CPE status
Advantech WebAccess Affected: All , ≤ 9.02 (custom)
guessed Create a notification for this product.
Date Public
2021-10-12 00:00
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T23:42:19.157Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-285-02"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "WebAccess",
          "vendor": "Advantech",
          "versions": [
            {
              "lessThanOrEqual": "9.02",
              "status": "affected",
              "version": "All",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "value": "Natnael Samson, @NattiSamson, working with Trend Micro\u2019s Zero Day Initiative, reported these vulnerabilities to CISA."
        }
      ],
      "datePublic": "2021-10-12T00:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "value": "Advantech WebAccess versions 9.02 and prior are vulnerable to a heap-based buffer overflow, which may allow an attacker to remotely execute code."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-122",
              "description": "HEAP-BASED BUFFER OVERFLOW CWE-122",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-10-18T12:41:08.000Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-285-02"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "value": "In order to address the heap-based buffer overflow vulnerability, Advantech recommends users directly add the remote access code to avoid being attacked by unknown requests. This is the remote access code established during installation of the Advantech WebAccess SCADA software (SCADA node, project node, or OPC Service) on the OPC Server computer. The access code you enter here must match the remote access code established during installation on the OPC Server. This prevents unauthorized users from accessing the OPC Server data using the Advantech WebAccess SCADA OPC Service.\n\nIf you have forgotten the remote access code using during software installation on the OPC Server node, you have two options:\n\nRe-install the Advantech WebAccess SCADA software on the OPC Server node to change it and edit it to match in your database.\nEdit the BWSERVER.INI file on the OPC Server node and edit it to match in your database using UPDATE."
        }
      ],
      "source": {
        "advisory": "ICSA-21-285-02",
        "discovery": "UNKNOWN"
      },
      "title": "Advantech WebAccess",
      "x_generator": {
        "engine": "Vulnogram 0.0.9"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "DATE_PUBLIC": "2021-10-12T19:15:00.000Z",
          "ID": "CVE-2021-33023",
          "STATE": "PUBLIC",
          "TITLE": "Advantech WebAccess"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "WebAccess",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c=",
                            "version_name": "All",
                            "version_value": "9.02"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Advantech"
              }
            ]
          }
        },
        "credit": [
          {
            "lang": "eng",
            "value": "Natnael Samson, @NattiSamson, working with Trend Micro\u2019s Zero Day Initiative, reported these vulnerabilities to CISA."
          }
        ],
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Advantech WebAccess versions 9.02 and prior are vulnerable to a heap-based buffer overflow, which may allow an attacker to remotely execute code."
            }
          ]
        },
        "generator": {
          "engine": "Vulnogram 0.0.9"
        },
        "impact": {
          "cvss": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "HEAP-BASED BUFFER OVERFLOW CWE-122"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://us-cert.cisa.gov/ics/advisories/icsa-21-285-02",
              "refsource": "MISC",
              "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-285-02"
            }
          ]
        },
        "solution": [
          {
            "lang": "en",
            "value": "In order to address the heap-based buffer overflow vulnerability, Advantech recommends users directly add the remote access code to avoid being attacked by unknown requests. This is the remote access code established during installation of the Advantech WebAccess SCADA software (SCADA node, project node, or OPC Service) on the OPC Server computer. The access code you enter here must match the remote access code established during installation on the OPC Server. This prevents unauthorized users from accessing the OPC Server data using the Advantech WebAccess SCADA OPC Service.\n\nIf you have forgotten the remote access code using during software installation on the OPC Server node, you have two options:\n\nRe-install the Advantech WebAccess SCADA software on the OPC Server node to change it and edit it to match in your database.\nEdit the BWSERVER.INI file on the OPC Server node and edit it to match in your database using UPDATE."
          }
        ],
        "source": {
          "advisory": "ICSA-21-285-02",
          "discovery": "UNKNOWN"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2021-33023",
    "datePublished": "2021-10-18T12:41:08.470Z",
    "dateReserved": "2021-05-13T00:00:00.000Z",
    "dateUpdated": "2024-09-17T03:49:19.278Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "epss": {
      "cve": "CVE-2021-33023",
      "date": "2026-11-11",
      "epss": "0.02346",
      "percentile": "0.8388"
    },
    "nvd": {
      "cve": {
        "configurations": [
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:a:advantech:webaccess:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "800E1EAB-1270-42C2-BECE-7110B4D3E9E2",
                    "versionEndIncluding": "9.0.2",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ]
          }
        ],
        "cveTags": [],
        "descriptions": [
          {
            "lang": "en",
            "value": "Advantech WebAccess versions 9.02 and prior are vulnerable to a heap-based buffer overflow, which may allow an attacker to remotely execute code."
          },
          {
            "lang": "es",
            "value": "Advantech WebAccess versiones 9.02 y anteriores, son vulnerables a un desbordamiento del b\u00fafer en la regi\u00f3n heap de la memoria, que puede permitir a un atacante ejecutar c\u00f3digo de forma remota"
          }
        ],
        "id": "CVE-2021-33023",
        "lastModified": "2024-11-21T06:08:08.777",
        "metrics": {
          "cvssMetricV2": [
            {
              "acInsufInfo": false,
              "baseSeverity": "HIGH",
              "cvssData": {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "availabilityImpact": "PARTIAL",
                "baseScore": 7.5,
                "confidentialityImpact": "PARTIAL",
                "integrityImpact": "PARTIAL",
                "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
                "version": "2.0"
              },
              "exploitabilityScore": 10.0,
              "impactScore": 6.4,
              "obtainAllPrivilege": false,
              "obtainOtherPrivilege": false,
              "obtainUserPrivilege": false,
              "source": "nvd@nist.gov",
              "type": "Primary",
              "userInteractionRequired": false
            }
          ],
          "cvssMetricV31": [
            {
              "cvssData": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 9.8,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "exploitabilityScore": 3.9,
              "impactScore": 5.9,
              "source": "ics-cert@hq.dhs.gov",
              "type": "Secondary"
            },
            {
              "cvssData": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 9.8,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "exploitabilityScore": 3.9,
              "impactScore": 5.9,
              "source": "nvd@nist.gov",
              "type": "Primary"
            }
          ]
        },
        "published": "2021-10-18T13:15:09.437",
        "references": [
          {
            "source": "ics-cert@hq.dhs.gov",
            "tags": [
              "Mitigation",
              "Third Party Advisory",
              "US Government Resource"
            ],
            "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-285-02"
          },
          {
            "source": "af854a3a-2127-422b-91ae-364da2661108",
            "tags": [
              "Mitigation",
              "Third Party Advisory",
              "US Government Resource"
            ],
            "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-285-02"
          }
        ],
        "sourceIdentifier": "ics-cert@hq.dhs.gov",
        "vulnStatus": "Modified",
        "weaknesses": [
          {
            "description": [
              {
                "lang": "en",
                "value": "CWE-122"
              }
            ],
            "source": "ics-cert@hq.dhs.gov",
            "type": "Secondary"
          },
          {
            "description": [
              {
                "lang": "en",
                "value": "CWE-787"
              }
            ],
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ]
      }
    },
    "redhat_vex": {
      "current_release_date": "2026-03-27T14:00:42+00:00",
      "cve": "CVE-2021-33023",
      "id": "CVE-2021-33023",
      "initial_release_date": "2021-10-12T00:00:00+00:00",
      "product_status:known_not_affected": "1",
      "source": "Red Hat CSAF VEX",
      "status": "final",
      "title": "Advantech WebAccess",
      "url": "https://security.access.redhat.com/data/csaf/v2/vex/2021/cve-2021-33023.json",
      "version": "3"
    }
  }
}



Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Drag nodes to arrange them. Double-click a related vulnerability to open it, or a source to visit its link. The Physics button on the left tunes the layout and the simulation; the legend at the bottom left hides or shows nodes by kind and by sighting type.

Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Vulnerability timeline

Sightings and recorded dates, grouped by day · UTC

JSON
How durations are calculated

Following the VTEM framework (Black Hat USA 2015), time to patch starts when the vendor or a coordinator was informed, total time to patch at discovery, and disclosure to patch at public disclosure; vendor response time runs from the report to its acknowledgement. Time to exploit and time unpatched start at the earliest discovery or report, falling back to public disclosure. Unpatched time ends at the first recorded patch, or the calculation time when no patch is recorded. Exploitation to patch shows the interval between those two events; a published proof of concept is a public exploit, not exploitation.

Each result shows its source dates. A negative interval means the end event came first; when date-only inputs leave the order open, the result says so. Date-only inputs are approximate. The earliest evidence wins: KEV report dates and sightings are labelled as such. Records describing another vulnerability are listed but never calculated from, and a PoC alone does not establish exploitation. Missing patch evidence does not prove that no patch exists. Filters below change the event list only.

Events included in the timeline

Loading timeline…


    Loading…

    Loading…

    Loading…

    Related by attack behaviour

    Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.