CVE-2021-26586 (GCVE-0-2021-26586)
Vulnerability from cvelistv5 – Published: 2021-08-05 20:40 – Updated: 2024-08-03 20:26
VLAI
Summary
A potential security vulnerability has been identified in the HPE Edgeline Infrastructure Manager, also known as HPE Edgeline Infrastructure Management Software. The vulnerability could be remotely exploited to disclose sensitive information. HPE has made software updates available to resolve the vulnerability in the HPE Edgeline Infrastructure Manager (EIM).
Severity
7.5 (High)
CWE
- remote disclosure of sensitive information
Assigner
References
2 references
| URL | Tags |
|---|---|
| https://support.hpe.com/hpsc/doc/public/display?d… | x_refsource_MISC |
| https://www.tenable.com/security/research/tra-2021-33 | x_refsource_MISC |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| n/a | HPE Edgeline Infrastructure Management Software |
Affected:
Prior to 1.24
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T20:26:25.469Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbgn04180en_us"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.tenable.com/security/research/tra-2021-33"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "HPE Edgeline Infrastructure Management Software",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "Prior to 1.24"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A potential security vulnerability has been identified in the HPE Edgeline Infrastructure Manager, also known as HPE Edgeline Infrastructure Management Software. The vulnerability could be remotely exploited to disclose sensitive information. HPE has made software updates available to resolve the vulnerability in the HPE Edgeline Infrastructure Manager (EIM)."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "remote disclosure of sensitive information",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-08-09T15:06:19.000Z",
"orgId": "eb103674-0d28-4225-80f8-39fb86215de0",
"shortName": "hpe"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbgn04180en_us"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.tenable.com/security/research/tra-2021-33"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "security-alert@hpe.com",
"ID": "CVE-2021-26586",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "HPE Edgeline Infrastructure Management Software",
"version": {
"version_data": [
{
"version_value": "Prior to 1.24"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A potential security vulnerability has been identified in the HPE Edgeline Infrastructure Manager, also known as HPE Edgeline Infrastructure Management Software. The vulnerability could be remotely exploited to disclose sensitive information. HPE has made software updates available to resolve the vulnerability in the HPE Edgeline Infrastructure Manager (EIM)."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "remote disclosure of sensitive information"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbgn04180en_us",
"refsource": "MISC",
"url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbgn04180en_us"
},
{
"name": "https://www.tenable.com/security/research/tra-2021-33",
"refsource": "MISC",
"url": "https://www.tenable.com/security/research/tra-2021-33"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "eb103674-0d28-4225-80f8-39fb86215de0",
"assignerShortName": "hpe",
"cveId": "CVE-2021-26586",
"datePublished": "2021-08-05T20:40:10.000Z",
"dateReserved": "2021-02-02T00:00:00.000Z",
"dateUpdated": "2024-08-03T20:26:25.469Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"epss": {
"cve": "CVE-2021-26586",
"date": "2026-06-22",
"epss": "0.01566",
"percentile": "0.72083"
},
"nvd": "{\"cve\":{\"id\":\"CVE-2021-26586\",\"sourceIdentifier\":\"security-alert@hpe.com\",\"published\":\"2021-08-05T21:15:11.780\",\"lastModified\":\"2024-11-21T05:56:32.150\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"A potential security vulnerability has been identified in the HPE Edgeline Infrastructure Manager, also known as HPE Edgeline Infrastructure Management Software. The vulnerability could be remotely exploited to disclose sensitive information. HPE has made software updates available to resolve the vulnerability in the HPE Edgeline Infrastructure Manager (EIM).\"},{\"lang\":\"es\",\"value\":\"Se ha identificado una posible vulnerabilidad de seguridad en HPE Edgeline Infrastructure Manager, tambi\u00e9n se conoce como HPE Edgeline Infrastructure Management Software. La vulnerabilidad podr\u00eda ser explotada remotamente para divulgar informaci\u00f3n confidencial. HPE ha puesto a disposici\u00f3n actualizaciones de software para resolver la vulnerabilidad en HPE Edgeline Infrastructure Manager (EIM)\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N\",\"baseScore\":7.5,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"NONE\"},\"exploitabilityScore\":3.9,\"impactScore\":3.6}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:L/Au:N/C:P/I:N/A:N\",\"baseScore\":5.0,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"LOW\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"PARTIAL\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"NONE\"},\"baseSeverity\":\"MEDIUM\",\"exploitabilityScore\":10.0,\"impactScore\":2.9,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"NVD-CWE-noinfo\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:hp:edgeline_infrastructure_management:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"1.24\",\"matchCriteriaId\":\"80F5C01F-0088-4DDF-BBD7-48C10D0951FF\"}]}]}],\"references\":[{\"url\":\"https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbgn04180en_us\",\"source\":\"security-alert@hpe.com\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://www.tenable.com/security/research/tra-2021-33\",\"source\":\"security-alert@hpe.com\",\"tags\":[\"Exploit\",\"Third Party Advisory\"]},{\"url\":\"https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbgn04180en_us\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://www.tenable.com/security/research/tra-2021-33\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Exploit\",\"Third Party Advisory\"]}]}}"
}
}
Loading…
Loading…
Experimental. This forecast is provided for visualization only and may change without notice. Do not use it for operational decisions.
Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…