CVE-2021-23846 (GCVE-0-2021-23846)
Vulnerability from cvelistv5 – Published: 2021-06-18 13:38 – Updated: 2024-09-16 16:38
VLAI
Title
B426 Credential Disclosure
Summary
When using http protocol, the user password is transmitted as a clear text parameter for which it is possible to be obtained by an attacker through a MITM attack. This will be fixed starting from Firmware version 3.11.5, which will be released on the 30th of June, 2021.
Severity
8.8 (High)
CWE
- CWE-319 - Cleartext Transmission of Sensitive Information
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://psirt.bosch.com/security-advisories/bosch… | x_refsource_CONFIRM |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Bosch | B426 Firmware |
Affected:
03.01.0004
Affected: 03.02.002 Affected: 03.05.0003 Affected: 03.03.0009 |
Date Public
2021-05-28 00:00
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T19:14:09.219Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://psirt.bosch.com/security-advisories/bosch-sa-196933-bt.html"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "B426\u00a0Firmware",
"vendor": "Bosch",
"versions": [
{
"status": "affected",
"version": "03.01.0004"
},
{
"status": "affected",
"version": "03.02.002"
},
{
"status": "affected",
"version": "03.05.0003"
},
{
"status": "affected",
"version": "03.03.0009"
}
]
}
],
"datePublic": "2021-05-28T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "When using http protocol, the user password is transmitted as a clear text parameter for which it is possible to be obtained by an attacker through a MITM attack. This will be fixed starting from Firmware version 3.11.5, which will be released on the 30th of June, 2021."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-319",
"description": "CWE-319 Cleartext Transmission of Sensitive Information",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-06-18T13:38:38.000Z",
"orgId": "c95f66b2-7e7c-41c5-8f09-6f86ec68659c",
"shortName": "bosch"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://psirt.bosch.com/security-advisories/bosch-sa-196933-bt.html"
}
],
"source": {
"advisory": "BOSCH-SA-196933-BT",
"discovery": "UNKNOWN"
},
"title": "B426 Credential Disclosure",
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "psirt@bosch.com",
"DATE_PUBLIC": "2021-05-28",
"ID": "CVE-2021-23846",
"STATE": "PUBLIC",
"TITLE": "B426 Credential Disclosure"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "B426\u00a0Firmware",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "03.01.0004"
},
{
"version_affected": "=",
"version_value": "03.02.002"
},
{
"version_affected": "=",
"version_value": "03.05.0003"
},
{
"version_affected": "=",
"version_value": "03.03.0009"
}
]
}
}
]
},
"vendor_name": "Bosch"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "When using http protocol, the user password is transmitted as a clear text parameter for which it is possible to be obtained by an attacker through a MITM attack. This will be fixed starting from Firmware version 3.11.5, which will be released on the 30th of June, 2021."
}
]
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-319 Cleartext Transmission of Sensitive Information"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://psirt.bosch.com/security-advisories/bosch-sa-196933-bt.html",
"refsource": "CONFIRM",
"url": "https://psirt.bosch.com/security-advisories/bosch-sa-196933-bt.html"
}
]
},
"source": {
"advisory": "BOSCH-SA-196933-BT",
"discovery": "UNKNOWN"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "c95f66b2-7e7c-41c5-8f09-6f86ec68659c",
"assignerShortName": "bosch",
"cveId": "CVE-2021-23846",
"datePublished": "2021-06-18T13:38:38.275Z",
"dateReserved": "2021-01-12T00:00:00.000Z",
"dateUpdated": "2024-09-16T16:38:12.268Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"epss": {
"cve": "CVE-2021-23846",
"date": "2026-05-25",
"epss": "0.00135",
"percentile": "0.32931"
},
"nvd": "{\"cve\":{\"id\":\"CVE-2021-23846\",\"sourceIdentifier\":\"psirt@bosch.com\",\"published\":\"2021-06-18T14:15:07.983\",\"lastModified\":\"2024-11-21T05:51:56.087\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"When using http protocol, the user password is transmitted as a clear text parameter for which it is possible to be obtained by an attacker through a MITM attack. This will be fixed starting from Firmware version 3.11.5, which will be released on the 30th of June, 2021.\"},{\"lang\":\"es\",\"value\":\"Cuando se usa el protocolo http, la contrase\u00f1a del usuario es transmitida como un par\u00e1metro de texto sin cifrar, por lo que es posible ser obtenida por un atacante mediante un ataque MITM. Esto ser\u00e1 corregido a partir desde Firmware versi\u00f3n 3.11.5, que ser\u00e1 publicado el 30 de junio de 2021\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"psirt@bosch.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H\",\"baseScore\":8.8,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"REQUIRED\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":2.8,\"impactScore\":5.9},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:N/A:N\",\"baseScore\":5.9,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"HIGH\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"NONE\"},\"exploitabilityScore\":2.2,\"impactScore\":3.6}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:M/Au:N/C:P/I:N/A:N\",\"baseScore\":4.3,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"MEDIUM\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"PARTIAL\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"NONE\"},\"baseSeverity\":\"MEDIUM\",\"exploitabilityScore\":8.6,\"impactScore\":2.9,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"psirt@bosch.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-319\"}]},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-319\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:bosch:b426_firmware:03.01.0004:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"5D8D9DF7-C733-4455-A653-D78298D1FABD\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:bosch:b426_firmware:03.02.002:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"31D05CDF-6F5E-4893-BA70-928BD83A50D6\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:bosch:b426_firmware:03.03.0009:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"00336848-27F3-45CD-B799-49BEA4FED80F\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:bosch:b426_firmware:03.05.0003:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"AD4F1647-A8A1-4AAF-8C31-0474EC9539F1\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:bosch:b426:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"F8846CF6-D7F7-4A65-BD96-F195D2EB1A22\"}]}]}],\"references\":[{\"url\":\"https://psirt.bosch.com/security-advisories/bosch-sa-196933-bt.html\",\"source\":\"psirt@bosch.com\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://psirt.bosch.com/security-advisories/bosch-sa-196933-bt.html\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Vendor Advisory\"]}]}}"
}
}
Loading…
Loading…
Experimental. This forecast is provided for visualization only and may change without notice. Do not use it for operational decisions.
Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…