CVE-2021-23276 (GCVE-0-2021-23276)
Vulnerability from cvelistv5 – Published: 2021-04-13 18:03 – Updated: 2024-09-17 02:22- CWE-89 - SQL Injection
| URL | Tags |
|---|---|
| https://www.eaton.com/content/dam/eaton/company/n… | x_refsource_MISC |
| Vendor | Product | Version | CPE status | |
|---|---|---|---|---|
| Eaton | Intelligent Power manager (IPM) |
Affected:
unspecified , < 1.69
(custom)
|
guessed |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T19:05:54.415Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.eaton.com/content/dam/eaton/company/news-insights/cybersecurity/security-bulletins/eaton-intelligent-power-manager-ipm-vulnerability-advisory.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Intelligent Power manager (IPM)",
"vendor": "Eaton",
"versions": [
{
"lessThan": "1.69",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"value": "Amir Preminger from Claroty research"
}
],
"datePublic": "2021-04-01T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "Eaton Intelligent Power Manager (IPM) prior to 1.69 is vulnerable to authenticated SQL injection. A malicious user can send a specially crafted packet to exploit the vulnerability. Successful exploitation of this vulnerability can allow attackers to add users in the data base."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.1,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-89",
"description": "CWE-89 SQL Injection",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-04-13T18:03:08.000Z",
"orgId": "63703b7d-23e2-41ef-94b3-a3c6333f7759",
"shortName": "Eaton"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.eaton.com/content/dam/eaton/company/news-insights/cybersecurity/security-bulletins/eaton-intelligent-power-manager-ipm-vulnerability-advisory.pdf"
}
],
"solutions": [
{
"lang": "en",
"value": "upgrade the software to latest version 1.69"
}
],
"source": {
"advisory": "ETN-VA-2021-1000",
"defect": [
"ETN-VA-2021-1000"
],
"discovery": "EXTERNAL"
},
"title": "Improper Neutralization of Special Elements used in an SQL Command",
"workarounds": [
{
"lang": "en",
"value": "To prevent the exploitation of the issues and safeguard the software from malicious entities, Eaton recommends blocking ports 4679 \u0026 4680 at the enterprise network or home network where Intelligent Power Manager (IPM) software is installed and used"
}
],
"x_generator": {
"engine": "Vulnogram 0.0.9"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"AKA": "SQL Injection",
"ASSIGNER": "CybersecurityCOE@eaton.com",
"DATE_PUBLIC": "2021-04-01T07:00:00.000Z",
"ID": "CVE-2021-23276",
"STATE": "PUBLIC",
"TITLE": "Improper Neutralization of Special Elements used in an SQL Command"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Intelligent Power manager (IPM)",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_value": "1.69"
}
]
}
}
]
},
"vendor_name": "Eaton"
}
]
}
},
"credit": [
{
"lang": "eng",
"value": "Amir Preminger from Claroty research"
}
],
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Eaton Intelligent Power Manager (IPM) prior to 1.69 is vulnerable to authenticated SQL injection. A malicious user can send a specially crafted packet to exploit the vulnerability. Successful exploitation of this vulnerability can allow attackers to add users in the data base."
}
]
},
"generator": {
"engine": "Vulnogram 0.0.9"
},
"impact": {
"cvss": {
"attackComplexity": "HIGH",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.1,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-89 SQL Injection"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.eaton.com/content/dam/eaton/company/news-insights/cybersecurity/security-bulletins/eaton-intelligent-power-manager-ipm-vulnerability-advisory.pdf",
"refsource": "MISC",
"url": "https://www.eaton.com/content/dam/eaton/company/news-insights/cybersecurity/security-bulletins/eaton-intelligent-power-manager-ipm-vulnerability-advisory.pdf"
}
]
},
"solution": [
{
"lang": "en",
"value": "upgrade the software to latest version 1.69"
}
],
"source": {
"advisory": "ETN-VA-2021-1000",
"defect": [
"ETN-VA-2021-1000"
],
"discovery": "EXTERNAL"
},
"work_around": [
{
"lang": "en",
"value": "To prevent the exploitation of the issues and safeguard the software from malicious entities, Eaton recommends blocking ports 4679 \u0026 4680 at the enterprise network or home network where Intelligent Power Manager (IPM) software is installed and used"
}
]
}
}
},
"cveMetadata": {
"assignerOrgId": "63703b7d-23e2-41ef-94b3-a3c6333f7759",
"assignerShortName": "Eaton",
"cveId": "CVE-2021-23276",
"datePublished": "2021-04-13T18:03:08.524Z",
"dateReserved": "2021-01-08T00:00:00.000Z",
"dateUpdated": "2024-09-17T02:22:03.243Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"epss": {
"cve": "CVE-2021-23276",
"date": "2026-11-13",
"epss": "0.00821",
"percentile": "0.57822"
},
"nvd": {
"cve": {
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:eaton:intelligent_power_manager:*:*:*:*:*:*:*:*",
"matchCriteriaId": "5E2C63CA-B479-49C4-8C98-F5AE9BF06A2F",
"versionEndExcluding": "1.69",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:eaton:intelligent_power_manager_virtual_appliance:*:*:*:*:*:*:*:*",
"matchCriteriaId": "10CFCD42-A9D6-468B-9287-03B4341B129A",
"versionEndExcluding": "1.69",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:eaton:intelligent_power_protector:*:*:*:*:*:*:*:*",
"matchCriteriaId": "4A67B7A8-E508-4854-9437-BF702692948C",
"versionEndExcluding": "1.68",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "Eaton Intelligent Power Manager (IPM) prior to 1.69 is vulnerable to authenticated SQL injection. A malicious user can send a specially crafted packet to exploit the vulnerability. Successful exploitation of this vulnerability can allow attackers to add users in the data base."
},
{
"lang": "es",
"value": "Eaton Intelligent Power Manager (IPM) versiones anteriores a 1.69, es vulnerable a una inyecci\u00f3n de SQL autenticado.\u0026#xa0;Un usuario malicioso puede enviar un paquete especialmente dise\u00f1ado para explotar la vulnerabilidad. Una explotaci\u00f3n con \u00e9xito de esta vulnerabilidad puede permitir a atacantes agregar usuarios a la base de datos"
}
],
"id": "CVE-2021-23276",
"lastModified": "2024-11-21T05:51:29.067",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "MEDIUM",
"cvssData": {
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "SINGLE",
"availabilityImpact": "PARTIAL",
"baseScore": 6.5,
"confidentialityImpact": "PARTIAL",
"integrityImpact": "PARTIAL",
"vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P",
"version": "2.0"
},
"exploitabilityScore": 8.0,
"impactScore": 6.4,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": false
}
],
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "HIGH",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.1,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 1.2,
"impactScore": 5.9,
"source": "CybersecurityCOE@eaton.com",
"type": "Secondary"
},
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 2.8,
"impactScore": 5.9,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2021-04-13T19:15:14.600",
"references": [
{
"source": "CybersecurityCOE@eaton.com",
"tags": [
"Vendor Advisory"
],
"url": "https://www.eaton.com/content/dam/eaton/company/news-insights/cybersecurity/security-bulletins/eaton-intelligent-power-manager-ipm-vulnerability-advisory.pdf"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Vendor Advisory"
],
"url": "https://www.eaton.com/content/dam/eaton/company/news-insights/cybersecurity/security-bulletins/eaton-intelligent-power-manager-ipm-vulnerability-advisory.pdf"
}
],
"sourceIdentifier": "CybersecurityCOE@eaton.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-89"
}
],
"source": "CybersecurityCOE@eaton.com",
"type": "Secondary"
},
{
"description": [
{
"lang": "en",
"value": "CWE-89"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
},
"redhat_vex": {
"current_release_date": "2026-03-27T14:46:46+00:00",
"cve": "CVE-2021-23276",
"id": "CVE-2021-23276",
"initial_release_date": "2021-04-01T00:00:00+00:00",
"product_status:known_not_affected": "1",
"source": "Red Hat CSAF VEX",
"status": "final",
"title": "Improper Neutralization of Special Elements used in an SQL Command",
"url": "https://security.access.redhat.com/data/csaf/v2/vex/2021/cve-2021-23276.json",
"version": "3"
}
}
}
Drag nodes to arrange them. Double-click a related vulnerability to open it, or a source to visit its link. The Physics button on the left tunes the layout and the simulation; the legend at the bottom left hides or shows nodes by kind and by sighting type.
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Vulnerability timeline
Sightings and recorded dates, grouped by day · UTC
How durations are calculated
Following the VTEM framework (Black Hat USA 2015), time to patch starts when the vendor or a coordinator was informed, total time to patch at discovery, and disclosure to patch at public disclosure; vendor response time runs from the report to its acknowledgement. Time to exploit and time unpatched start at the earliest discovery or report, falling back to public disclosure. Unpatched time ends at the first recorded patch, or the calculation time when no patch is recorded. Exploitation to patch shows the interval between those two events; a published proof of concept is a public exploit, not exploitation.
Each result shows its source dates. A negative interval means the end event came first; when date-only inputs leave the order open, the result says so. Date-only inputs are approximate. The earliest evidence wins: KEV report dates and sightings are labelled as such. Records describing another vulnerability are listed but never calculated from, and a PoC alone does not establish exploitation. Missing patch evidence does not prove that no patch exists. Filters below change the event list only.
Loading timeline…
The approach is described in our paper Mapping CVEs to MITRE ATT&CK Techniques: A Curated Gold-Set Classifier and the Limits of LLM-Assisted Label Expansion.
Browse all ATT&CK techniques and the vulnerabilities related to each.
Related by attack behaviour
Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.