CVE-2021-22701 (GCVE-0-2021-22701)
Vulnerability from cvelistv5 – Published: 2021-02-19 15:15 – Updated: 2024-08-03 18:51- CWE-352 - Cross-Site Request Forgery
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
| Vendor | Product | Version | ||
|---|---|---|---|---|
| n/a | PowerLogic ION7400, ION7650, ION83xx/84xx/85xx/8600, ION8650, ION8800, ION9000 and PM800 (see notification for affected versions) |
Affected:
EcoStruxure™ Operator Terminal Expert 3.1 Service Pack 1A and prior running on Harmony HMIs HMIST6 Series, HMIG3U in HMIGTU Series, HMISTO Series and Pro-face BLUE 3.1 Service Pack 1A and prior running on Pro-face HMIs: ST6000 Series, SP-5B41 in SP5000 Series, GP4100 Series
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T18:51:07.099Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.se.com/ww/en/download/document/SEVD-2021-040-01/"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "PowerLogic ION7400, ION7650, ION83xx/84xx/85xx/8600, ION8650, ION8800, ION9000 and PM800 (see notification for affected versions)",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "EcoStruxure\u2122 Operator Terminal Expert 3.1 Service Pack 1A and prior running on Harmony HMIs HMIST6 Series, HMIG3U in HMIGTU Series, HMISTO Series and Pro-face BLUE 3.1 Service Pack 1A and prior running on Pro-face HMIs: ST6000 Series, SP-5B41 in SP5000 Series, GP4100 Series"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A CWE-352: Cross-Site Request Forgery vulnerability exists in PowerLogic ION7400, ION7650, ION83xx/84xx/85xx/8600, ION8650, ION8800, ION9000 and PM800 (see notification for affected versions), that could cause a user to perform an unintended action on the target device when using the HTTP web interface."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-352",
"description": "CWE-352: Cross-Site Request Forgery",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-02-19T15:15:16",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.se.com/ww/en/download/document/SEVD-2021-040-01/"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cybersecurity@schneider-electric.com",
"ID": "CVE-2021-22701",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "PowerLogic ION7400, ION7650, ION83xx/84xx/85xx/8600, ION8650, ION8800, ION9000 and PM800 (see notification for affected versions)",
"version": {
"version_data": [
{
"version_value": "EcoStruxure\u2122 Operator Terminal Expert 3.1 Service Pack 1A and prior running on Harmony HMIs HMIST6 Series, HMIG3U in HMIGTU Series, HMISTO Series and Pro-face BLUE 3.1 Service Pack 1A and prior running on Pro-face HMIs: ST6000 Series, SP-5B41 in SP5000 Series, GP4100 Series"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A CWE-352: Cross-Site Request Forgery vulnerability exists in PowerLogic ION7400, ION7650, ION83xx/84xx/85xx/8600, ION8650, ION8800, ION9000 and PM800 (see notification for affected versions), that could cause a user to perform an unintended action on the target device when using the HTTP web interface."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-352: Cross-Site Request Forgery"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.se.com/ww/en/download/document/SEVD-2021-040-01/",
"refsource": "MISC",
"url": "https://www.se.com/ww/en/download/document/SEVD-2021-040-01/"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2021-22701",
"datePublished": "2021-02-19T15:15:16",
"dateReserved": "2021-01-06T00:00:00",
"dateUpdated": "2024-08-03T18:51:07.099Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"nvd": "{\"cve\":{\"id\":\"CVE-2021-22701\",\"sourceIdentifier\":\"cybersecurity@se.com\",\"published\":\"2021-02-19T16:15:12.937\",\"lastModified\":\"2024-11-21T05:50:29.377\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"A CWE-352: Cross-Site Request Forgery vulnerability exists in PowerLogic ION7400, ION7650, ION83xx/84xx/85xx/8600, ION8650, ION8800, ION9000 and PM800 (see notification for affected versions), that could cause a user to perform an unintended action on the target device when using the HTTP web interface.\"},{\"lang\":\"es\",\"value\":\"Una CWE-352: Se presenta una vulnerabilidad de tipo Cross-Site Request Forgery en PowerLogic ION7400, ION7650, ION83xx/84xx/85xx/8600, ION8650, ION8800, ION9000 y PM800 (consulte la notificaci\u00f3n para las versiones afectadas), que podr\u00eda causar que un usuario lleve a cabo una acci\u00f3n no deseada en el dispositivo de destino cuando se usa la interfaz web HTTP\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:U/C:N/I:H/A:N\",\"baseScore\":4.5,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"HIGH\",\"userInteraction\":\"REQUIRED\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"NONE\"},\"exploitabilityScore\":0.9,\"impactScore\":3.6}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:M/Au:S/C:N/I:P/A:N\",\"baseScore\":3.5,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"MEDIUM\",\"authentication\":\"SINGLE\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"PARTIAL\",\"availabilityImpact\":\"NONE\"},\"baseSeverity\":\"LOW\",\"exploitabilityScore\":6.8,\"impactScore\":2.9,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":true}]},\"weaknesses\":[{\"source\":\"cybersecurity@se.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-352\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:schneider-electric:powerlogic_ion7400_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"3.0.0\",\"matchCriteriaId\":\"DCE7015C-02DD-44A1-ADEE-5E71CE312266\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:schneider-electric:powerlogic_ion7400:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"C8F28EAA-FC60-4CE0-BD39-DFD3EB88E195\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:schneider-electric:powerlogic_ion7410:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"C23FEAFC-9F15-4214-BF9C-A33130362110\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:schneider-electric:powerlogic_ion7650_firmware:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"C1647241-A18D-4E4C-A118-8809EA625FC7\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:schneider-electric:powerlogic_ion7650:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"0DF2D964-79EF-43F2-9AC6-D263F75BAFA0\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:schneider-electric:powerlogic_ion8600_firmware:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"DB6B0276-AB51-4B8F-B2A7-85EDD56C9E7C\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:schneider-electric:powerlogic_ion8600:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"324CF58A-753C-4D9C-8E72-FC8EE26EDA0D\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:schneider-electric:powerlogic_ion8650_firmware:*:*:*:*:*:*:*:*\",\"versionEndIncluding\":\"4.31.2\",\"matchCriteriaId\":\"5D91486A-36CD-49A9-8A45-EDAA75F05E50\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:schneider-electric:powerlogic_ion8650:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"FBC3A306-D4F4-4C2A-9D60-DD8F0826AEEC\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:schneider-electric:powerlogic_ion8800_firmware:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"C95DCE16-BAA5-46DD-835B-2299376387CD\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:schneider-electric:powerlogic_ion8800:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"46E8E79E-6DA7-4094-9622-3B91D5913493\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:schneider-electric:powerlogic_ion9000_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"3.0.0\",\"matchCriteriaId\":\"32067EA8-5153-4A00-9DE8-C4BEC42C00A6\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:schneider-electric:powerlogic_ion9000:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"6718EAAA-074D-4807-AC2D-DD0A06D397FB\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:schneider-electric:powerlogic_pm8000_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"3.0.0\",\"matchCriteriaId\":\"E5A75862-E1AC-4C6E-83AD-DE5FCD8BA50D\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:schneider-electric:powerlogic_pm8000:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"B16A7BEC-1BED-4A61-A6C9-BF7DB13B998C\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:schneider-electric:powerlogic_ion8300_firmware:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"1047C892-B7F5-49FB-AB36-8E8061A58037\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:schneider-electric:powerlogic_ion8300:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"F01E9FE2-4110-4A6D-99F3-49784808D951\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:schneider-electric:powerlogic_ion8400_firmware:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"70BAC583-6101-4F26-A264-26E5D69E9188\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:schneider-electric:powerlogic_ion8400:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"82527983-6167-4D7B-A70A-D1A814ED3D06\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:schneider-electric:powerlogic_ion8500_firmware:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"768FB179-B6D7-457C-9795-310400460F6E\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:schneider-electric:powerlogic_ion8500:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"75E37742-CFF9-4F80-9B6A-0D4F5AD23112\"}]}]}],\"references\":[{\"url\":\"https://www.se.com/ww/en/download/document/SEVD-2021-040-01/\",\"source\":\"cybersecurity@se.com\",\"tags\":[\"Mitigation\",\"Vendor Advisory\"]},{\"url\":\"https://www.se.com/ww/en/download/document/SEVD-2021-040-01/\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Mitigation\",\"Vendor Advisory\"]}]}}"
}
}
CVE-2021-22701
Vulnerability from csaf_se - Published: 2021-02-08 00:00 - Updated: 2021-02-08 00:00Notes
{
"document": {
"category": "csaf_security_advisory",
"csaf_version": "2.0",
"distribution": {
"text": "Public",
"tlp": {
"label": "WHITE"
}
},
"lang": "en-US",
"notes": [
{
"category": "general",
"text": "We strongly recommend the following industry cybersecurity best practices.\n\nhttps://www.se.com/us/en/download/document/7EN52-0390/\n* Locate control and safety system networks and remote devices behind firewalls and isolate them from the business network.\n* Install physical controls so no unauthorized personnel can access your industrial control and safety systems, components, peripheral equipment, and networks.\n* Place all controllers in locked cabinets and never leave them in the \u201cProgram\u201d mode.\n* Never connect programming software to any network other than the network intended for that device.\n* Scan all methods of mobile data exchange with the isolated network such as CDs, USB drives, etc. before use in the terminals or any node connected to these networks.\n* Never allow mobile devices that have connected to any other network besides the intended network to connect to the safety or control networks without proper sanitation.\n* Minimize network exposure for all control system devices and systems and ensure that they are not accessible from the Internet.\n* When remote access is required, use secure methods, such as Virtual Private Networks (VPNs). Recognize that VPNs may have vulnerabilities and should be updated to the most current version available. Also, understand that VPNs are only as secure as the connected devices.\nFor more information refer to the Schneider Electric Recommended Cybersecurity Best Practices document. \n",
"title": "General Security Recommendations"
},
{
"category": "general",
"text": "This document provides an overview of the identified vulnerability or vulnerabilities and actions required to mitigate. For more details and assistance on how to protect your installation, contact your local Schneider Electric representative or Schneider Electric Industrial Cybersecurity Services: https://www.se.com/ww/en/work/solutions/cybersecurity/. These organizations will be fully aware of this situation and can support you through the process.\nFor further information related to cybersecurity in Schneider Electric\u2019s products, visit the company\u2019s cybersecurity support portal page: https://www.se.com/ww/en/work/support/cybersecurity/overview.jsp",
"title": "For More Information"
},
{
"category": "legal_disclaimer",
"text": "THIS NOTIFICATION DOCUMENT, THE INFORMATION CONTAINED HEREIN, AND ANY MATERIALS LINKED FROM IT (COLLECTIVELY, THIS \u201cNOTIFICATION\u201d) ARE INTENDED TO HELP PROVIDE AN OVERVIEW OF THE IDENTIFIED SITUATION AND SUGGESTED MITIGATION ACTIONS, REMEDIATION, FIX, AND/OR GENERAL SECURITY RECOMMENDATIONS AND IS PROVIDED ON AN \u201cAS-IS\u201d BASIS WITHOUT WARRANTY OR GUARANTEE OF ANY KIND. SCHNEIDER ELECTRIC DISCLAIMS ALL WARRANTIES RELATING TO THIS NOTIFICATION, EITHER EXPRESS OR IMPLIED, INCLUDING WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. SCHNEIDER ELECTRIC MAKES NO WARRANTY THAT THE NOTIFICATION WILL RESOLVE THE IDENTIFIED SITUATION. IN NO EVENT SHALL SCHNEIDER ELECTRIC BE LIABLE FOR ANY DAMAGES OR LOSSES WHATSOEVER IN CONNECTION WITH THIS NOTIFICATION, INCLUDING DIRECT, INDIRECT, INCIDENTAL, CONSEQUENTIAL, LOSS OF BUSINESS PROFITS OR SPECIAL DAMAGES, EVEN IF SCHNEIDER ELECTRIC HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. YOUR USE OF THIS NOTIFICATION IS AT YOUR OWN RISK, AND YOU ARE SOLELY LIABLE FOR ANY DAMAGES TO YOUR SYSTEMS OR ASSETS OR OTHER LOSSES THAT MAY RESULT FROM YOUR USE OF THIS NOTIFICATION. SCHNEIDER ELECTRIC RESERVES THE RIGHT TO UPDATE OR CHANGE THIS NOTIFICATION AT ANY TIME AND IN ITS SOLE DISCRETION",
"title": "LEGAL DISCLAIMER"
},
{
"category": "general",
"text": "At Schneider, we believe access to energy and digital is a basic human right. We empower all to do more with less, ensuring Life Is On everywhere, for everyone, at every moment.\n\nWe provide energy and automation digital solutions for efficiency and sustainability. We combine world-leading energy technologies, real-time automation, software and services into integrated solutions for Homes, Buildings, Data Centers, Infrastructure and Industries.\n\nWe are committed to unleash the infinite possibilities of an open, global, innovative community that is passionate with our Meaningful Purpose, Inclusive and Empowered values.\n\nwww.se.com ",
"title": "About Schneider Electric"
},
{
"category": "summary",
"text": "Schneider Electric is aware of multiple vulnerabilities in its PowerLogic ION7400, ION7650, \r\nION7700/73xx, ION83xx/84xx/85xx/8600, ION8650, ION8800, ION9000 and PM8000 products. \r\nThe PowerLogic metering products are revenue and power quality meters for utility and \r\nindustrial electrical network monitoring. \r\nFailure to apply the mitigations/remediations provided below may risk disclosure of user \r\ncredentials when using HTTP or Telnet protocol or cause a user to perform an unintended \r\naction on a target device when using HTTP, which could result in unintended device behavior.",
"title": "Overview"
},
{
"category": "summary",
"text": "Customers should use appropriate methodologies when applying these upgrades to their devices. We strongly recommend evaluating the impact of these updates in a test and development environment prior to deployment. Contact Schneider Electric\u0027s Customer Care Center if you need assistance reverting to an older version of firmware.",
"title": "Overview"
}
],
"publisher": {
"category": "vendor",
"contact_details": "cpcert@se.com",
"name": "Schneider Electric CPCERT",
"namespace": "https://www.se.com/ww/en/work/support/cybersecurity/security-notifications.jsp"
},
"references": [
{
"category": "self",
"summary": "PowerLogic Power Metering Products - SEVD-2021-040-01 PDF Version",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-040-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2021-040-01_PowerLogic_Power_Metering_Security_Notification.pdf"
},
{
"category": "self",
"summary": "PowerLogic Power Metering Products - SEVD-2021-040-01 CSAF Version",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-040-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=sevd-2021-040-01.json"
},
{
"category": "external",
"summary": "Recommended Cybersecurity Best Practices",
"url": "https://www.se.com/us/en/download/document/7EN52-0390/"
}
],
"title": "PowerLogic Power Metering Products",
"tracking": {
"current_release_date": "2021-02-08T00:00:00.000Z",
"generator": {
"date": "2021-02-08T00:00:00Z",
"engine": {
"name": "Schneider Electric CSAF Generator",
"version": "1.2"
}
},
"id": "SEVD-2021-040-01",
"initial_release_date": "2021-02-08T00:00:00.000Z",
"revision_history": [
{
"date": "2021-02-08T00:00:00.000Z",
"number": "1.0.0",
"summary": "Original Release"
}
],
"status": "final",
"version": "1.0.0"
}
},
"product_tree": {
"branches": [
{
"branches": [
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c3.0.0",
"product": {
"name": "Schneider Electric ION7400 All versions prior to V3.0.0",
"product_id": "1"
}
}
],
"category": "product_name",
"name": "ION7400"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "Schneider Electric ION7650 All versions",
"product_id": "2"
}
}
],
"category": "product_name",
"name": "ION7650"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "Schneider Electric ION7700/73xx All versions. Note: Only affected by CVE-2021-22702 as these products do not support HTTP web functionality.",
"product_id": "3"
}
}
],
"category": "product_name",
"name": "ION7700/73xx"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "Schneider Electric ION83xx/84xx/85xx/8600 All versions",
"product_id": "4"
}
}
],
"category": "product_name",
"name": "ION83xx/84xx/85xx/8600"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c=4.31.2",
"product": {
"name": "Schneider Electric ION8650 V 4.31.2 and prior",
"product_id": "5"
}
}
],
"category": "product_name",
"name": "ION8650"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "Schneider Electric ION8800 All versions",
"product_id": "6"
}
}
],
"category": "product_name",
"name": "ION8800"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c3.0.0",
"product": {
"name": "Schneider Electric ION9000 All versions prior to V3.0.0",
"product_id": "7"
}
}
],
"category": "product_name",
"name": "ION9000"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c3.0.0",
"product": {
"name": "Schneider Electric PM8000 All versions prior to V3.0.0",
"product_id": "8"
}
}
],
"category": "product_name",
"name": "PM8000"
},
{
"branches": [
{
"category": "product_version",
"name": "3.0.0",
"product": {
"name": "Schneider Electric PowerLogic ION7400 V3.0.0",
"product_id": "9"
}
}
],
"category": "product_name",
"name": "PowerLogic ION7400"
},
{
"branches": [
{
"category": "product_version",
"name": "4.40.1",
"product": {
"name": "Schneider Electric PowerLogic ION8650 V4.40.1",
"product_id": "10"
}
}
],
"category": "product_name",
"name": "PowerLogic ION8650"
},
{
"branches": [
{
"category": "product_version",
"name": "3.0.0",
"product": {
"name": "Schneider Electric PowerLogic ION9000 V3.0.0",
"product_id": "11"
}
}
],
"category": "product_name",
"name": "PowerLogic ION9000"
},
{
"branches": [
{
"category": "product_version",
"name": "3.0.0",
"product": {
"name": "Schneider Electric PowerLogic PM8000 V3.0.0",
"product_id": "12"
}
}
],
"category": "product_name",
"name": "PowerLogic PM8000"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c2.1.0|\u003e2.2.1",
"product": {
"name": "Schneider Electric ION7400 v2.1.0 to V2.2.1",
"product_id": "13"
}
}
],
"category": "product_name",
"name": "ION7400"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c2.1.0|\u003e2.2.1",
"product": {
"name": "Schneider Electric PM8000 V2.1.0 to V2.2.1",
"product_id": "14"
}
}
],
"category": "product_name",
"name": "PM8000"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c2.1.0",
"product": {
"name": "Schneider Electric ION7400 prior to V2.1.0",
"product_id": "15"
}
}
],
"category": "product_name",
"name": "ION7400"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c2.1.0",
"product": {
"name": "Schneider Electric PM8000 prior to V2.1.0",
"product_id": "16"
}
}
],
"category": "product_name",
"name": "PM8000"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c4.20.1|\u003e4.31.2",
"product": {
"name": "Schneider Electric ION8650 V4.20.1 to 4.31.2",
"product_id": "17"
}
}
],
"category": "product_name",
"name": "ION8650"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003e=415",
"product": {
"name": "Schneider Electric ION7650 V415 or later",
"product_id": "18"
}
}
],
"category": "product_name",
"name": "ION7650"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003e= 362",
"product": {
"name": "Schneider Electric ION8800 V362 or later",
"product_id": "19"
}
}
],
"category": "product_name",
"name": "ION8800"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c4.20.1",
"product": {
"name": "Schneider Electric ION8650 prior to V4.20.1",
"product_id": "20"
}
}
],
"category": "product_name",
"name": "ION8650"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c415",
"product": {
"name": "Schneider Electric ION7650 prior to V415",
"product_id": "21"
}
}
],
"category": "product_name",
"name": "ION7650"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c362",
"product": {
"name": "Schneider Electric ION8800 prior to V362",
"product_id": "22"
}
}
],
"category": "product_name",
"name": "ION8800"
}
],
"category": "vendor",
"name": "Schneider Electric"
}
]
},
"vulnerabilities": [
{
"cve": "CVE-2021-22701",
"cwe": {
"id": "CWE-352",
"name": "Cross-Site Request Forgery (CSRF)"
},
"notes": [
{
"category": "description",
"text": "CWE-352: Cross-Site Request Forgery vulnerability exists that could cause a user to perform \r\nan unintended action on the target device when using the HTTP web interface.",
"title": "CVE Description"
}
],
"product_status": {
"fixed": [
"9",
"10",
"11",
"12"
],
"known_affected": [
"1",
"2",
"4",
"5",
"6",
"7",
"8"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "V3.0.0 of the PowerLogic ION7400 firmware includes fixes\r\nfor these vulnerabilities by replacing Telnet functionality \r\nwith SSH. Additionally, HTTP web interface was removed \r\n(only HTTPS mode now supported). The version update \r\nfiles are available for download here:\r\nhttps://www.se.com/ww/en/download/document/ION7400_\r\nmeter_FW_v003.000.000/\r\nNote: There may be newer versions of the firmware \r\navailable for download, please check the ION7400 https://www.se.com/us/en/product-range-download/63502-powerlogic-ion7400-series/#/software-firmware-tab product \r\npage on se.com before upgrading.\r\nCustomers who do not wish to apply this remediation \r\nshould refer to the mitigations below.",
"product_ids": [
"1"
],
"restart_required": {
"category": "none"
},
"url": "https://www.se.com/ww/en/download/document/ION7400_meter_FW_v003.000.000/"
},
{
"category": "vendor_fix",
"details": "V4.40.1 of the PowerLogic ION8650 firmware includes fixes\r\nfor these vulnerabilities by replacing Telnet functionality \r\nwith SSH and making web pages read only. The version \r\nupdate files are available for download here: \r\nhttps://www.se.com/ww/en/download/document/ION8650_\r\nmeter_FW_V004.040.001/\r\nNote: There may be newer versions of the firmware \r\navailable for download, please check the ION8650 https://www.se.com/us/en/product-range-download/61053-powerlogic-ion8650-series/?selected-node-id=12144491661#/software-firmware-tab product \r\npage on se.com before upgrading.\r\nCustomers who do not wish to apply this remediation \r\nshould refer to the mitigations below.",
"product_ids": [
"5"
],
"restart_required": {
"category": "none"
},
"url": "https://www.se.com/ww/en/download/document/ION8650_meter_FW_V004.040.001/"
},
{
"category": "vendor_fix",
"details": "V3.0.0 of the PowerLogic ION9000 firmware includes fixes\r\nfor these vulnerabilities by replacing telnet functionality with \r\nSSH. Additionally, HTTP web interface was removed (only \r\nHTTPS mode now supported). The version update files are\r\navailable for download here:\r\nhttps://www.se.com/ww/en/download/document/ION9000_\r\nmeter_FW_v003.000.000/\r\nNote: There may be newer versions of the firmware \r\navailable for download, please check the ION9000 https://www.se.com/us/en/product-range-download/64241-powerlogic-ion9000-series/#/software-firmware-tab product \r\npage on se.com before upgrading.\r\nCustomers who do not wish to apply this remediation \r\nshould refer to the mitigations below.",
"product_ids": [
"7"
],
"restart_required": {
"category": "none"
},
"url": "https://www.se.com/ww/en/download/document/ION9000_meter_FW_v003.000.000/"
},
{
"category": "vendor_fix",
"details": "V3.0.0 of the PowerLogic PM8000 firmware includes fixes\r\nfor these vulnerabilities by replacing telnet functionality with \r\nSSH. Additionally, HTTP web interface was removed (only \r\nHTTPS mode now supported). The version update files are\r\navailable for download here:\r\nhttps://www.se.com/ww/en/download/document/PM8000_m\r\neter_FW_v003.000.000/ \r\nNote: There may be newer versions of the firmware \r\navailable for download, please check the ION8000 https://www.se.com/us/en/product-range-download/62252-powerlogic-pm8000-series/#/software-firmware-tab product \r\npage on se.com before upgrading.\r\nCustomers who do not wish to apply this remediation \r\nshould refer to the mitigations below.",
"product_ids": [
"8"
],
"restart_required": {
"category": "none"
},
"url": "https://www.se.com/ww/en/download/document/PM8000_meter_FW_v003.000.000/"
},
{
"category": "mitigation",
"details": "A remediation does not exist for these products, please \r\nrefer to the Mitigations section below for information on how \r\nto reduce the risk of exploit. ",
"product_ids": [
"2",
"4",
"6"
],
"restart_required": {
"category": "none"
}
},
{
"category": "mitigation",
"details": "Customers should immediately apply the following mitigations \r\nto reduce the risk of exploit:\r\n\u2022 Disable Telnet functionality\r\n\u2022 To mitigate plain text HTTP, ensure HTTPS is enabled\r\n\u2022 To mitigate Cross-Site request forgery, disable HTTP\r\nand HTTPS web functionality",
"product_ids": [
"7"
],
"restart_required": {
"category": "none"
}
},
{
"category": "mitigation",
"details": "Customers should immediately apply the following mitigations \r\nto reduce the risk of exploit:\r\n\u2022 Disable Telnet functionality\r\n\u2022 To mitigate plain text HTTP, ensure HTTPS is enabled\r\n\u2022 To mitigate Cross-Site request forgery, disable HTTP\r\nand HTTPS web functionality",
"product_ids": [
"7",
"13",
"14"
],
"restart_required": {
"category": "none"
}
},
{
"category": "mitigation",
"details": "Customers should immediately apply the following mitigations \r\nto reduce the risk of exploit:\r\n\u2022 Disable Telnet functionality\r\n\u2022 Disable HTTP functionality",
"product_ids": [
"15",
"16"
],
"restart_required": {
"category": "none"
}
},
{
"category": "mitigation",
"details": "Customers should immediately apply the following mitigations \r\nto reduce the risk of exploit:\r\n\u2022 Disable Telnet functionality\r\n\u2022 Disable HTTP web functionality",
"product_ids": [
"17",
"18",
"19"
],
"restart_required": {
"category": "none"
}
},
{
"category": "mitigation",
"details": "Customers should immediately apply the following mitigations \r\nto reduce the risk of exploit:\r\n\u2022 Disable HTTP web functionality\r\nA mitigation does not exist for Telnet access. Please upgrade \r\nto a newer firmware version and apply the appropriate \r\nmitigation.",
"product_ids": [
"20",
"21",
"22"
],
"restart_required": {
"category": "none"
}
},
{
"category": "mitigation",
"details": "These products are no longer within a support period. \r\nCustomers should immediately apply the following mitigations \r\nto reduce the risk of exploit:\r\n\u2022 Disable HTTP web functionality\r\nA mitigation does not exist for Telnet access. Customers \r\nshould also consider upgrading to the latest product offering \r\nPowerLogic ION8650 https://www.se.com/ww/en/product-range/61053-powerlogic-ion8650/ to resolve these vulnerabilities. \r\n",
"product_ids": [
"4"
],
"restart_required": {
"category": "none"
},
"url": "https://www.se.com/ww/en/product-range/61053-powerlogic-ion8650/"
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 6.1,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:R/S:U/C:N/I:H/A:H",
"version": "3.0"
},
"products": [
"1",
"2",
"4",
"5",
"6",
"7",
"8"
]
}
],
"title": "CVE-2021-22701"
},
{
"cve": "CVE-2021-22702",
"cwe": {
"id": "CWE-319",
"name": "Cleartext Transmission of Sensitive Information"
},
"notes": [
{
"category": "description",
"text": "CWE-319: Cleartext transmission of sensitive information vulnerability exists that could \r\ncause disclosure of user credentials when a malicious actor intercepts Telnet network traffic \r\nbetween a user and the device.",
"title": "CVE Description"
}
],
"product_status": {
"fixed": [
"9",
"10",
"11",
"12"
],
"known_affected": [
"1",
"2",
"3",
"4",
"5",
"6",
"7",
"8"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "V3.0.0 of the PowerLogic ION7400 firmware includes fixes\r\nfor these vulnerabilities by replacing Telnet functionality \r\nwith SSH. Additionally, HTTP web interface was removed \r\n(only HTTPS mode now supported). The version update \r\nfiles are available for download here:\r\nhttps://www.se.com/ww/en/download/document/ION7400_\r\nmeter_FW_v003.000.000/\r\nNote: There may be newer versions of the firmware \r\navailable for download, please check the ION7400 https://www.se.com/us/en/product-range-download/63502-powerlogic-ion7400-series/#/software-firmware-tab product \r\npage on se.com before upgrading.\r\nCustomers who do not wish to apply this remediation \r\nshould refer to the mitigations below.",
"product_ids": [
"1"
],
"restart_required": {
"category": "none"
},
"url": "https://www.se.com/ww/en/download/document/ION7400_meter_FW_v003.000.000/"
},
{
"category": "vendor_fix",
"details": "V4.40.1 of the PowerLogic ION8650 firmware includes fixes\r\nfor these vulnerabilities by replacing Telnet functionality \r\nwith SSH and making web pages read only. The version \r\nupdate files are available for download here: \r\nhttps://www.se.com/ww/en/download/document/ION8650_\r\nmeter_FW_V004.040.001/\r\nNote: There may be newer versions of the firmware \r\navailable for download, please check the ION8650 https://www.se.com/us/en/product-range-download/61053-powerlogic-ion8650-series/?selected-node-id=12144491661#/software-firmware-tab product \r\npage on se.com before upgrading.\r\nCustomers who do not wish to apply this remediation \r\nshould refer to the mitigations below.",
"product_ids": [
"5"
],
"restart_required": {
"category": "none"
},
"url": "https://www.se.com/ww/en/download/document/ION8650_meter_FW_V004.040.001/"
},
{
"category": "vendor_fix",
"details": "V3.0.0 of the PowerLogic ION9000 firmware includes fixes\r\nfor these vulnerabilities by replacing telnet functionality with \r\nSSH. Additionally, HTTP web interface was removed (only \r\nHTTPS mode now supported). The version update files are\r\navailable for download here:\r\nhttps://www.se.com/ww/en/download/document/ION9000_\r\nmeter_FW_v003.000.000/\r\nNote: There may be newer versions of the firmware \r\navailable for download, please check the ION9000 https://www.se.com/us/en/product-range-download/64241-powerlogic-ion9000-series/#/software-firmware-tab product \r\npage on se.com before upgrading.\r\nCustomers who do not wish to apply this remediation \r\nshould refer to the mitigations below.",
"product_ids": [
"7"
],
"restart_required": {
"category": "none"
},
"url": "https://www.se.com/ww/en/download/document/ION9000_meter_FW_v003.000.000/"
},
{
"category": "vendor_fix",
"details": "V3.0.0 of the PowerLogic PM8000 firmware includes fixes\r\nfor these vulnerabilities by replacing telnet functionality with \r\nSSH. Additionally, HTTP web interface was removed (only \r\nHTTPS mode now supported). The version update files are\r\navailable for download here:\r\nhttps://www.se.com/ww/en/download/document/PM8000_m\r\neter_FW_v003.000.000/ \r\nNote: There may be newer versions of the firmware \r\navailable for download, please check the ION8000 https://www.se.com/us/en/product-range-download/62252-powerlogic-pm8000-series/#/software-firmware-tab product \r\npage on se.com before upgrading.\r\nCustomers who do not wish to apply this remediation \r\nshould refer to the mitigations below.",
"product_ids": [
"8"
],
"restart_required": {
"category": "none"
},
"url": "https://www.se.com/ww/en/download/document/PM8000_meter_FW_v003.000.000/"
},
{
"category": "mitigation",
"details": "A remediation does not exist for these products, please \r\nrefer to the Mitigations section below for information on how \r\nto reduce the risk of exploit. ",
"product_ids": [
"2",
"3",
"4",
"6"
],
"restart_required": {
"category": "none"
}
},
{
"category": "mitigation",
"details": "Customers should immediately apply the following mitigations \r\nto reduce the risk of exploit:\r\n\u2022 Disable Telnet functionality\r\n\u2022 To mitigate plain text HTTP, ensure HTTPS is enabled\r\n\u2022 To mitigate Cross-Site request forgery, disable HTTP\r\nand HTTPS web functionality",
"product_ids": [
"7"
],
"restart_required": {
"category": "none"
}
},
{
"category": "mitigation",
"details": "Customers should immediately apply the following mitigations \r\nto reduce the risk of exploit:\r\n\u2022 Disable Telnet functionality\r\n\u2022 To mitigate plain text HTTP, ensure HTTPS is enabled\r\n\u2022 To mitigate Cross-Site request forgery, disable HTTP\r\nand HTTPS web functionality",
"product_ids": [
"7",
"13",
"14"
],
"restart_required": {
"category": "none"
}
},
{
"category": "mitigation",
"details": "Customers should immediately apply the following mitigations \r\nto reduce the risk of exploit:\r\n\u2022 Disable Telnet functionality\r\n\u2022 Disable HTTP functionality",
"product_ids": [
"15",
"16"
],
"restart_required": {
"category": "none"
}
},
{
"category": "mitigation",
"details": "Customers should immediately apply the following mitigations \r\nto reduce the risk of exploit:\r\n\u2022 Disable Telnet functionality\r\n\u2022 Disable HTTP web functionality",
"product_ids": [
"17",
"18",
"19"
],
"restart_required": {
"category": "none"
}
},
{
"category": "mitigation",
"details": "Customers should immediately apply the following mitigations \r\nto reduce the risk of exploit:\r\n\u2022 Disable HTTP web functionality\r\nA mitigation does not exist for Telnet access. Please upgrade \r\nto a newer firmware version and apply the appropriate \r\nmitigation.",
"product_ids": [
"20",
"21",
"22"
],
"restart_required": {
"category": "none"
}
},
{
"category": "mitigation",
"details": "These products are no longer within a support period. \r\nCustomers should immediately apply the following mitigations \r\nto reduce the risk of exploit:\r\n\u2022 Disable HTTP web functionality\r\nA mitigation does not exist for Telnet access. Customers \r\nshould also consider upgrading to the latest product offering \r\nPowerLogic ION8650 https://www.se.com/ww/en/product-range/61053-powerlogic-ion8650/ to resolve these vulnerabilities. \r\n",
"product_ids": [
"4"
],
"restart_required": {
"category": "none"
},
"url": "https://www.se.com/ww/en/product-range/61053-powerlogic-ion8650/"
},
{
"category": "mitigation",
"details": "These products are no longer within a support period.\r\nA mitigation does not exist for Telnet access. Customers \r\nshould consider upgrading to the latest product offering \r\nPowerLogic ION9000 https://www.se.com/ww/en/product-range/64241-powerlogic%E2%84%A2-ion9000/ , PowerLogic PM8000 https://www.se.com/ww/en/product-range/62252-powerlogic-pm8000-series/ , or PowerLogic \r\nION7400 https://www.se.com/ww/en/product-range/63502-powerlogic-ion7400/ to resolve these vulnerabilities.",
"product_ids": [
"3"
],
"restart_required": {
"category": "none"
},
"url": "https://www.se.com/ww/en/product-range/64241-powerlogic-ion9000/#products,https://www.se.com/ww/en/product-range/62252-powerlogic-pm8000-series/,https://www.se.com/ww/en/product-range/63502-powerlogic-ion7400/"
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
"version": "3.0"
},
"products": [
"1",
"2",
"3",
"4",
"5",
"6",
"7",
"8"
]
}
],
"title": "CVE-2021-22702"
},
{
"cve": "CVE-2021-22703",
"cwe": {
"id": "CWE-319",
"name": "Cleartext Transmission of Sensitive Information"
},
"notes": [
{
"category": "description",
"text": "CWE-319: Cleartext transmission of sensitive information vulnerability exists that could \r\ncause disclosure of user credentials when a malicious actor intercepts HTTP network traffic \r\nbetween a user and the device.",
"title": "CVE Description"
}
],
"product_status": {
"fixed": [
"9",
"10",
"11",
"12"
],
"known_affected": [
"1",
"2",
"4",
"5",
"6",
"7",
"8"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "V3.0.0 of the PowerLogic ION7400 firmware includes fixes\r\nfor these vulnerabilities by replacing Telnet functionality \r\nwith SSH. Additionally, HTTP web interface was removed \r\n(only HTTPS mode now supported). The version update \r\nfiles are available for download here:\r\nhttps://www.se.com/ww/en/download/document/ION7400_\r\nmeter_FW_v003.000.000/\r\nNote: There may be newer versions of the firmware \r\navailable for download, please check the ION7400 https://www.se.com/us/en/product-range-download/63502-powerlogic-ion7400-series/#/software-firmware-tab product \r\npage on se.com before upgrading.\r\nCustomers who do not wish to apply this remediation \r\nshould refer to the mitigations below.",
"product_ids": [
"1"
],
"restart_required": {
"category": "none"
},
"url": "https://www.se.com/ww/en/download/document/ION7400_meter_FW_v003.000.000/"
},
{
"category": "vendor_fix",
"details": "V4.40.1 of the PowerLogic ION8650 firmware includes fixes\r\nfor these vulnerabilities by replacing Telnet functionality \r\nwith SSH and making web pages read only. The version \r\nupdate files are available for download here: \r\nhttps://www.se.com/ww/en/download/document/ION8650_\r\nmeter_FW_V004.040.001/\r\nNote: There may be newer versions of the firmware \r\navailable for download, please check the ION8650 https://www.se.com/us/en/product-range-download/61053-powerlogic-ion8650-series/?selected-node-id=12144491661#/software-firmware-tab product \r\npage on se.com before upgrading.\r\nCustomers who do not wish to apply this remediation \r\nshould refer to the mitigations below.",
"product_ids": [
"5"
],
"restart_required": {
"category": "none"
},
"url": "https://www.se.com/ww/en/download/document/ION8650_meter_FW_V004.040.001/"
},
{
"category": "vendor_fix",
"details": "V3.0.0 of the PowerLogic ION9000 firmware includes fixes\r\nfor these vulnerabilities by replacing telnet functionality with \r\nSSH. Additionally, HTTP web interface was removed (only \r\nHTTPS mode now supported). The version update files are\r\navailable for download here:\r\nhttps://www.se.com/ww/en/download/document/ION9000_\r\nmeter_FW_v003.000.000/\r\nNote: There may be newer versions of the firmware \r\navailable for download, please check the ION9000 https://www.se.com/us/en/product-range-download/64241-powerlogic-ion9000-series/#/software-firmware-tab product \r\npage on se.com before upgrading.\r\nCustomers who do not wish to apply this remediation \r\nshould refer to the mitigations below.",
"product_ids": [
"7"
],
"restart_required": {
"category": "none"
},
"url": "https://www.se.com/ww/en/download/document/ION9000_meter_FW_v003.000.000/"
},
{
"category": "vendor_fix",
"details": "V3.0.0 of the PowerLogic PM8000 firmware includes fixes\r\nfor these vulnerabilities by replacing telnet functionality with \r\nSSH. Additionally, HTTP web interface was removed (only \r\nHTTPS mode now supported). The version update files are\r\navailable for download here:\r\nhttps://www.se.com/ww/en/download/document/PM8000_m\r\neter_FW_v003.000.000/ \r\nNote: There may be newer versions of the firmware \r\navailable for download, please check the ION8000 https://www.se.com/us/en/product-range-download/62252-powerlogic-pm8000-series/#/software-firmware-tab product \r\npage on se.com before upgrading.\r\nCustomers who do not wish to apply this remediation \r\nshould refer to the mitigations below.",
"product_ids": [
"8"
],
"restart_required": {
"category": "none"
},
"url": "https://www.se.com/ww/en/download/document/PM8000_meter_FW_v003.000.000/"
},
{
"category": "mitigation",
"details": "A remediation does not exist for these products, please \r\nrefer to the Mitigations section below for information on how \r\nto reduce the risk of exploit. ",
"product_ids": [
"2",
"4",
"6"
],
"restart_required": {
"category": "none"
}
},
{
"category": "mitigation",
"details": "Customers should immediately apply the following mitigations \r\nto reduce the risk of exploit:\r\n\u2022 Disable Telnet functionality\r\n\u2022 To mitigate plain text HTTP, ensure HTTPS is enabled\r\n\u2022 To mitigate Cross-Site request forgery, disable HTTP\r\nand HTTPS web functionality",
"product_ids": [
"7"
],
"restart_required": {
"category": "none"
}
},
{
"category": "mitigation",
"details": "Customers should immediately apply the following mitigations \r\nto reduce the risk of exploit:\r\n\u2022 Disable Telnet functionality\r\n\u2022 To mitigate plain text HTTP, ensure HTTPS is enabled\r\n\u2022 To mitigate Cross-Site request forgery, disable HTTP\r\nand HTTPS web functionality",
"product_ids": [
"7",
"13",
"14"
],
"restart_required": {
"category": "none"
}
},
{
"category": "mitigation",
"details": "Customers should immediately apply the following mitigations \r\nto reduce the risk of exploit:\r\n\u2022 Disable Telnet functionality\r\n\u2022 Disable HTTP functionality",
"product_ids": [
"15",
"16"
],
"restart_required": {
"category": "none"
}
},
{
"category": "mitigation",
"details": "Customers should immediately apply the following mitigations \r\nto reduce the risk of exploit:\r\n\u2022 Disable Telnet functionality\r\n\u2022 Disable HTTP web functionality",
"product_ids": [
"17",
"18",
"19"
],
"restart_required": {
"category": "none"
}
},
{
"category": "mitigation",
"details": "Customers should immediately apply the following mitigations \r\nto reduce the risk of exploit:\r\n\u2022 Disable HTTP web functionality\r\nA mitigation does not exist for Telnet access. Please upgrade \r\nto a newer firmware version and apply the appropriate \r\nmitigation.",
"product_ids": [
"20",
"21",
"22"
],
"restart_required": {
"category": "none"
}
},
{
"category": "mitigation",
"details": "These products are no longer within a support period. \r\nCustomers should immediately apply the following mitigations \r\nto reduce the risk of exploit:\r\n\u2022 Disable HTTP web functionality\r\nA mitigation does not exist for Telnet access. Customers \r\nshould also consider upgrading to the latest product offering \r\nPowerLogic ION8650 https://www.se.com/ww/en/product-range/61053-powerlogic-ion8650/ to resolve these vulnerabilities. \r\n",
"product_ids": [
"4"
],
"restart_required": {
"category": "none"
},
"url": "https://www.se.com/ww/en/product-range/61053-powerlogic-ion8650/"
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
"version": "3.0"
},
"products": [
"1",
"2",
"4",
"5",
"6",
"7",
"8"
]
}
],
"title": "CVE-2021-22703"
}
]
}
VAR-202102-0527
Vulnerability from variot - Updated: 2024-11-23 22:11A CWE-352: Cross-Site Request Forgery vulnerability exists in PowerLogic ION7400, ION7650, ION83xx/84xx/85xx/8600, ION8650, ION8800, ION9000 and PM800 (see notification for affected versions), that could cause a user to perform an unintended action on the target device when using the HTTP web interface.
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202102-0527",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "powerlogic ion7650",
"scope": "eq",
"trust": 1.0,
"vendor": "schneider electric",
"version": "*"
},
{
"model": "powerlogic ion9000",
"scope": "lt",
"trust": 1.0,
"vendor": "schneider electric",
"version": "3.0.0"
},
{
"model": "powerlogic ion8500",
"scope": "eq",
"trust": 1.0,
"vendor": "schneider electric",
"version": "*"
},
{
"model": "powerlogic ion8400",
"scope": "eq",
"trust": 1.0,
"vendor": "schneider electric",
"version": "*"
},
{
"model": "powerlogic ion8300",
"scope": "eq",
"trust": 1.0,
"vendor": "schneider electric",
"version": "*"
},
{
"model": "powerlogic ion8650",
"scope": "lte",
"trust": 1.0,
"vendor": "schneider electric",
"version": "4.31.2"
},
{
"model": "powerlogic pm8000",
"scope": "lt",
"trust": 1.0,
"vendor": "schneider electric",
"version": "3.0.0"
},
{
"model": "powerlogic ion7400",
"scope": "lt",
"trust": 1.0,
"vendor": "schneider electric",
"version": "3.0.0"
},
{
"model": "powerlogic ion8800",
"scope": "eq",
"trust": 1.0,
"vendor": "schneider electric",
"version": "*"
},
{
"model": "powerlogic ion8600",
"scope": "eq",
"trust": 1.0,
"vendor": "schneider electric",
"version": "*"
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2021-22701"
}
]
},
"cve": "CVE-2021-22701",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"accessComplexity": "MEDIUM",
"accessVector": "NETWORK",
"authentication": "SINGLE",
"author": "nvd@nist.gov",
"availabilityImpact": "NONE",
"baseScore": 3.5,
"confidentialityImpact": "NONE",
"exploitabilityScore": 6.8,
"id": "CVE-2021-22701",
"impactScore": 2.9,
"integrityImpact": "PARTIAL",
"severity": "LOW",
"trust": 1.0,
"vectorString": "AV:N/AC:M/Au:S/C:N/I:P/A:N",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "nvd@nist.gov",
"availabilityImpact": "NONE",
"baseScore": 4.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"exploitabilityScore": 0.9,
"id": "CVE-2021-22701",
"impactScore": 3.6,
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:U/C:N/I:H/A:N",
"version": "3.1"
}
],
"severity": [
{
"author": "nvd@nist.gov",
"id": "CVE-2021-22701",
"trust": 1.0,
"value": "MEDIUM"
},
{
"author": "CNNVD",
"id": "CNNVD-202102-1429",
"trust": 0.6,
"value": "MEDIUM"
}
]
}
],
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202102-1429"
},
{
"db": "NVD",
"id": "CVE-2021-22701"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "A CWE-352: Cross-Site Request Forgery vulnerability exists in PowerLogic ION7400, ION7650, ION83xx/84xx/85xx/8600, ION8650, ION8800, ION9000 and PM800 (see notification for affected versions), that could cause a user to perform an unintended action on the target device when using the HTTP web interface.",
"sources": [
{
"db": "NVD",
"id": "CVE-2021-22701"
}
],
"trust": 1.0
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2021-22701",
"trust": 1.6
},
{
"db": "SCHNEIDER",
"id": "SEVD-2021-040-01",
"trust": 1.6
},
{
"db": "CNNVD",
"id": "CNNVD-202102-1429",
"trust": 0.6
}
],
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202102-1429"
},
{
"db": "NVD",
"id": "CVE-2021-22701"
}
]
},
"id": "VAR-202102-0527",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "VARIoT devices database",
"id": null
}
],
"trust": 1.0
},
"last_update_date": "2024-11-23T22:11:07.945000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "Schneider PowerLogic Repair measures for product cross-site request forgery vulnerability",
"trust": 0.6,
"url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=142862"
}
],
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202102-1429"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-352",
"trust": 1.0
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2021-22701"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 1.6,
"url": "https://www.se.com/ww/en/download/document/sevd-2021-040-01/"
},
{
"trust": 0.6,
"url": "https://nvd.nist.gov/vuln/detail/cve-2021-22701"
}
],
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202102-1429"
},
{
"db": "NVD",
"id": "CVE-2021-22701"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "CNNVD",
"id": "CNNVD-202102-1429"
},
{
"db": "NVD",
"id": "CVE-2021-22701"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2021-02-19T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202102-1429"
},
{
"date": "2021-02-19T16:15:12.937000",
"db": "NVD",
"id": "CVE-2021-22701"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2022-03-10T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202102-1429"
},
{
"date": "2024-11-21T05:50:29.377000",
"db": "NVD",
"id": "CVE-2021-22701"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202102-1429"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Schneider PowerLogic Product Cross-Site Request Forgery Vulnerability",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202102-1429"
}
],
"trust": 0.6
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "cross-site request forgery",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202102-1429"
}
],
"trust": 0.6
}
}
CNVD-2021-13226
Vulnerability from cnvd - Published: 2021-02-27目前厂商已发布升级补丁以修复漏洞,补丁获取链接: https://www.se.com/ww/en/download/document/SEVD-2021-040-01/
| Name | F5 BIG-IP |
|---|
{
"cves": {
"cve": {
"cveNumber": "CVE-2021-22701",
"cveUrl": "https://nvd.nist.gov/vuln/detail/CVE-2021-22701"
}
},
"description": "F5 BIG-IP\u662f\u7f8e\u56fdF5\u516c\u53f8\u7684\u4e00\u6b3e\u96c6\u6210\u4e86\u7f51\u7edc\u6d41\u91cf\u7ba1\u7406\u3001\u5e94\u7528\u7a0b\u5e8f\u5b89\u5168\u7ba1\u7406\u3001\u8d1f\u8f7d\u5747\u8861\u7b49\u529f\u80fd\u7684\u5e94\u7528\u4ea4\u4ed8\u5e73\u53f0\u3002\n\nBIG-IP\u4e2d\u5b58\u5728\u7f13\u51b2\u533a\u6ea2\u51fa\u6f0f\u6d1e\uff0c\u8be5\u6f0f\u6d1e\u6e90\u4e8e\u7f51\u7edc\u7cfb\u7edf\u6216\u4ea7\u54c1\u5728\u5185\u5b58\u4e0a\u6267\u884c\u64cd\u4f5c\u65f6\uff0c\u672a\u6b63\u786e\u9a8c\u8bc1\u6570\u636e\u8fb9\u754c\uff0c\u5bfc\u81f4\u5411\u5173\u8054\u7684\u5176\u4ed6\u5185\u5b58\u4f4d\u7f6e\u4e0a\u6267\u884c\u4e86\u9519\u8bef\u7684\u8bfb\u5199\u64cd\u4f5c\u3002\u653b\u51fb\u8005\u53ef\u5229\u7528\u8be5\u6f0f\u6d1e\u5bfc\u81f4\u7f13\u51b2\u533a\u6ea2\u51fa\u6216\u5806\u6ea2\u51fa\u7b49\u3002",
"formalWay": "\u76ee\u524d\u5382\u5546\u5df2\u53d1\u5e03\u5347\u7ea7\u8865\u4e01\u4ee5\u4fee\u590d\u6f0f\u6d1e\uff0c\u8865\u4e01\u83b7\u53d6\u94fe\u63a5\uff1a\r\nhttps://www.se.com/ww/en/download/document/SEVD-2021-040-01/",
"isEvent": "\u901a\u7528\u8f6f\u786c\u4ef6\u6f0f\u6d1e",
"number": "CNVD-2021-13226",
"openTime": "2021-02-27",
"patchDescription": "F5 BIG-IP\u662f\u7f8e\u56fdF5\u516c\u53f8\u7684\u4e00\u6b3e\u96c6\u6210\u4e86\u7f51\u7edc\u6d41\u91cf\u7ba1\u7406\u3001\u5e94\u7528\u7a0b\u5e8f\u5b89\u5168\u7ba1\u7406\u3001\u8d1f\u8f7d\u5747\u8861\u7b49\u529f\u80fd\u7684\u5e94\u7528\u4ea4\u4ed8\u5e73\u53f0\u3002\r\n\r\nBIG-IP\u4e2d\u5b58\u5728\u7f13\u51b2\u533a\u6ea2\u51fa\u6f0f\u6d1e\uff0c\u8be5\u6f0f\u6d1e\u6e90\u4e8e\u7f51\u7edc\u7cfb\u7edf\u6216\u4ea7\u54c1\u5728\u5185\u5b58\u4e0a\u6267\u884c\u64cd\u4f5c\u65f6\uff0c\u672a\u6b63\u786e\u9a8c\u8bc1\u6570\u636e\u8fb9\u754c\uff0c\u5bfc\u81f4\u5411\u5173\u8054\u7684\u5176\u4ed6\u5185\u5b58\u4f4d\u7f6e\u4e0a\u6267\u884c\u4e86\u9519\u8bef\u7684\u8bfb\u5199\u64cd\u4f5c\u3002\u653b\u51fb\u8005\u53ef\u5229\u7528\u8be5\u6f0f\u6d1e\u5bfc\u81f4\u7f13\u51b2\u533a\u6ea2\u51fa\u6216\u5806\u6ea2\u51fa\u7b49\u3002\u76ee\u524d\uff0c\u4f9b\u5e94\u5546\u53d1\u5e03\u4e86\u5b89\u5168\u516c\u544a\u53ca\u76f8\u5173\u8865\u4e01\u4fe1\u606f\uff0c\u4fee\u590d\u4e86\u6b64\u6f0f\u6d1e\u3002",
"patchName": "F5 BIG-IP\u7f13\u51b2\u533a\u6ea2\u51fa\u6f0f\u6d1e\uff08CNVD-2021-13226\uff09\u7684\u8865\u4e01",
"products": {
"product": "F5 BIG-IP"
},
"referenceLink": "https://nvd.nist.gov/vuln/detail/CVE-2021-22701",
"serverity": "\u4f4e",
"submitTime": "2021-02-21",
"title": "F5 BIG-IP\u7f13\u51b2\u533a\u6ea2\u51fa\u6f0f\u6d1e\uff08CNVD-2021-13226\uff09"
}
GHSA-F3X2-W4CQ-5V25
Vulnerability from github – Published: 2022-05-24 17:42 – Updated: 2022-05-24 17:42A CWE-352: Cross-Site Request Forgery vulnerability exists in PowerLogic ION7400, ION7650, ION83xx/84xx/85xx/8600, ION8650, ION8800, ION9000 and PM800 (see notification for affected versions), that could cause a user to perform an unintended action on the target device when using the HTTP web interface.
{
"affected": [],
"aliases": [
"CVE-2021-22701"
],
"database_specific": {
"cwe_ids": [
"CWE-352"
],
"github_reviewed": false,
"github_reviewed_at": null,
"nvd_published_at": "2021-02-19T16:15:00Z",
"severity": "MODERATE"
},
"details": "A CWE-352: Cross-Site Request Forgery vulnerability exists in PowerLogic ION7400, ION7650, ION83xx/84xx/85xx/8600, ION8650, ION8800, ION9000 and PM800 (see notification for affected versions), that could cause a user to perform an unintended action on the target device when using the HTTP web interface.",
"id": "GHSA-f3x2-w4cq-5v25",
"modified": "2022-05-24T17:42:41Z",
"published": "2022-05-24T17:42:41Z",
"references": [
{
"type": "ADVISORY",
"url": "https://nvd.nist.gov/vuln/detail/CVE-2021-22701"
},
{
"type": "WEB",
"url": "https://www.se.com/ww/en/download/document/SEVD-2021-040-01"
}
],
"schema_version": "1.4.0",
"severity": []
}
GSD-2021-22701
Vulnerability from gsd - Updated: 2023-12-13 01:23{
"GSD": {
"alias": "CVE-2021-22701",
"description": "A CWE-352: Cross-Site Request Forgery vulnerability exists in PowerLogic ION7400, ION7650, ION83xx/84xx/85xx/8600, ION8650, ION8800, ION9000 and PM800 (see notification for affected versions), that could cause a user to perform an unintended action on the target device when using the HTTP web interface.",
"id": "GSD-2021-22701"
},
"gsd": {
"metadata": {
"exploitCode": "unknown",
"remediation": "unknown",
"reportConfidence": "confirmed",
"type": "vulnerability"
},
"osvSchema": {
"aliases": [
"CVE-2021-22701"
],
"details": "A CWE-352: Cross-Site Request Forgery vulnerability exists in PowerLogic ION7400, ION7650, ION83xx/84xx/85xx/8600, ION8650, ION8800, ION9000 and PM800 (see notification for affected versions), that could cause a user to perform an unintended action on the target device when using the HTTP web interface.",
"id": "GSD-2021-22701",
"modified": "2023-12-13T01:23:24.561360Z",
"schema_version": "1.4.0"
}
},
"namespaces": {
"cve.org": {
"CVE_data_meta": {
"ASSIGNER": "cybersecurity@schneider-electric.com",
"ID": "CVE-2021-22701",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "PowerLogic ION7400, ION7650, ION83xx/84xx/85xx/8600, ION8650, ION8800, ION9000 and PM800 (see notification for affected versions)",
"version": {
"version_data": [
{
"version_value": "EcoStruxure\u2122 Operator Terminal Expert 3.1 Service Pack 1A and prior running on Harmony HMIs HMIST6 Series, HMIG3U in HMIGTU Series, HMISTO Series and Pro-face BLUE 3.1 Service Pack 1A and prior running on Pro-face HMIs: ST6000 Series, SP-5B41 in SP5000 Series, GP4100 Series"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A CWE-352: Cross-Site Request Forgery vulnerability exists in PowerLogic ION7400, ION7650, ION83xx/84xx/85xx/8600, ION8650, ION8800, ION9000 and PM800 (see notification for affected versions), that could cause a user to perform an unintended action on the target device when using the HTTP web interface."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-352: Cross-Site Request Forgery"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.se.com/ww/en/download/document/SEVD-2021-040-01/",
"refsource": "MISC",
"url": "https://www.se.com/ww/en/download/document/SEVD-2021-040-01/"
}
]
}
},
"nvd.nist.gov": {
"configurations": {
"CVE_data_version": "4.0",
"nodes": [
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:schneider-electric:powerlogic_ion7400_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "3.0.0",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:schneider-electric:powerlogic_ion7400:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
},
{
"cpe23Uri": "cpe:2.3:h:schneider-electric:powerlogic_ion7410:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:schneider-electric:powerlogic_ion7650_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:schneider-electric:powerlogic_ion7650:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:schneider-electric:powerlogic_ion8600_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:schneider-electric:powerlogic_ion8600:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:schneider-electric:powerlogic_ion8650_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndIncluding": "4.31.2",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:schneider-electric:powerlogic_ion8650:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:schneider-electric:powerlogic_ion8800_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:schneider-electric:powerlogic_ion8800:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:schneider-electric:powerlogic_ion9000_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "3.0.0",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:schneider-electric:powerlogic_ion9000:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:schneider-electric:powerlogic_pm8000_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "3.0.0",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:schneider-electric:powerlogic_pm8000:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:schneider-electric:powerlogic_ion8300_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:schneider-electric:powerlogic_ion8300:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:schneider-electric:powerlogic_ion8400_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:schneider-electric:powerlogic_ion8400:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:schneider-electric:powerlogic_ion8500_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:schneider-electric:powerlogic_ion8500:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
}
]
},
"cve": {
"CVE_data_meta": {
"ASSIGNER": "cybersecurity@schneider-electric.com",
"ID": "CVE-2021-22701"
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "en",
"value": "A CWE-352: Cross-Site Request Forgery vulnerability exists in PowerLogic ION7400, ION7650, ION83xx/84xx/85xx/8600, ION8650, ION8800, ION9000 and PM800 (see notification for affected versions), that could cause a user to perform an unintended action on the target device when using the HTTP web interface."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "en",
"value": "CWE-352"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.se.com/ww/en/download/document/SEVD-2021-040-01/",
"refsource": "MISC",
"tags": [
"Mitigation",
"Vendor Advisory"
],
"url": "https://www.se.com/ww/en/download/document/SEVD-2021-040-01/"
}
]
}
},
"impact": {
"baseMetricV2": {
"acInsufInfo": false,
"cvssV2": {
"accessComplexity": "MEDIUM",
"accessVector": "NETWORK",
"authentication": "SINGLE",
"availabilityImpact": "NONE",
"baseScore": 3.5,
"confidentialityImpact": "NONE",
"integrityImpact": "PARTIAL",
"vectorString": "AV:N/AC:M/Au:S/C:N/I:P/A:N",
"version": "2.0"
},
"exploitabilityScore": 6.8,
"impactScore": 2.9,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"severity": "LOW",
"userInteractionRequired": true
},
"baseMetricV3": {
"cvssV3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 4.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:U/C:N/I:H/A:N",
"version": "3.1"
},
"exploitabilityScore": 0.9,
"impactScore": 3.6
}
},
"lastModifiedDate": "2022-02-03T16:15Z",
"publishedDate": "2021-02-19T16:15Z"
}
}
}
FKIE_CVE-2021-22701
Vulnerability from fkie_nvd - Published: 2021-02-19 16:15 - Updated: 2024-11-21 05:50| URL | Tags | ||
|---|---|---|---|
| cybersecurity@se.com | https://www.se.com/ww/en/download/document/SEVD-2021-040-01/ | Mitigation, Vendor Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | https://www.se.com/ww/en/download/document/SEVD-2021-040-01/ | Mitigation, Vendor Advisory |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:schneider-electric:powerlogic_ion7400_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "DCE7015C-02DD-44A1-ADEE-5E71CE312266",
"versionEndExcluding": "3.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:schneider-electric:powerlogic_ion7400:-:*:*:*:*:*:*:*",
"matchCriteriaId": "C8F28EAA-FC60-4CE0-BD39-DFD3EB88E195",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:schneider-electric:powerlogic_ion7410:-:*:*:*:*:*:*:*",
"matchCriteriaId": "C23FEAFC-9F15-4214-BF9C-A33130362110",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:schneider-electric:powerlogic_ion7650_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "C1647241-A18D-4E4C-A118-8809EA625FC7",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:schneider-electric:powerlogic_ion7650:-:*:*:*:*:*:*:*",
"matchCriteriaId": "0DF2D964-79EF-43F2-9AC6-D263F75BAFA0",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:schneider-electric:powerlogic_ion8600_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "DB6B0276-AB51-4B8F-B2A7-85EDD56C9E7C",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:schneider-electric:powerlogic_ion8600:-:*:*:*:*:*:*:*",
"matchCriteriaId": "324CF58A-753C-4D9C-8E72-FC8EE26EDA0D",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:schneider-electric:powerlogic_ion8650_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "5D91486A-36CD-49A9-8A45-EDAA75F05E50",
"versionEndIncluding": "4.31.2",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:schneider-electric:powerlogic_ion8650:-:*:*:*:*:*:*:*",
"matchCriteriaId": "FBC3A306-D4F4-4C2A-9D60-DD8F0826AEEC",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:schneider-electric:powerlogic_ion8800_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "C95DCE16-BAA5-46DD-835B-2299376387CD",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:schneider-electric:powerlogic_ion8800:-:*:*:*:*:*:*:*",
"matchCriteriaId": "46E8E79E-6DA7-4094-9622-3B91D5913493",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:schneider-electric:powerlogic_ion9000_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "32067EA8-5153-4A00-9DE8-C4BEC42C00A6",
"versionEndExcluding": "3.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:schneider-electric:powerlogic_ion9000:-:*:*:*:*:*:*:*",
"matchCriteriaId": "6718EAAA-074D-4807-AC2D-DD0A06D397FB",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:schneider-electric:powerlogic_pm8000_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "E5A75862-E1AC-4C6E-83AD-DE5FCD8BA50D",
"versionEndExcluding": "3.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:schneider-electric:powerlogic_pm8000:-:*:*:*:*:*:*:*",
"matchCriteriaId": "B16A7BEC-1BED-4A61-A6C9-BF7DB13B998C",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:schneider-electric:powerlogic_ion8300_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "1047C892-B7F5-49FB-AB36-8E8061A58037",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:schneider-electric:powerlogic_ion8300:-:*:*:*:*:*:*:*",
"matchCriteriaId": "F01E9FE2-4110-4A6D-99F3-49784808D951",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:schneider-electric:powerlogic_ion8400_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "70BAC583-6101-4F26-A264-26E5D69E9188",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:schneider-electric:powerlogic_ion8400:-:*:*:*:*:*:*:*",
"matchCriteriaId": "82527983-6167-4D7B-A70A-D1A814ED3D06",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:schneider-electric:powerlogic_ion8500_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "768FB179-B6D7-457C-9795-310400460F6E",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:schneider-electric:powerlogic_ion8500:-:*:*:*:*:*:*:*",
"matchCriteriaId": "75E37742-CFF9-4F80-9B6A-0D4F5AD23112",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "A CWE-352: Cross-Site Request Forgery vulnerability exists in PowerLogic ION7400, ION7650, ION83xx/84xx/85xx/8600, ION8650, ION8800, ION9000 and PM800 (see notification for affected versions), that could cause a user to perform an unintended action on the target device when using the HTTP web interface."
},
{
"lang": "es",
"value": "Una CWE-352: Se presenta una vulnerabilidad de tipo Cross-Site Request Forgery en PowerLogic ION7400, ION7650, ION83xx/84xx/85xx/8600, ION8650, ION8800, ION9000 y PM800 (consulte la notificaci\u00f3n para las versiones afectadas), que podr\u00eda causar que un usuario lleve a cabo una acci\u00f3n no deseada en el dispositivo de destino cuando se usa la interfaz web HTTP"
}
],
"id": "CVE-2021-22701",
"lastModified": "2024-11-21T05:50:29.377",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "LOW",
"cvssData": {
"accessComplexity": "MEDIUM",
"accessVector": "NETWORK",
"authentication": "SINGLE",
"availabilityImpact": "NONE",
"baseScore": 3.5,
"confidentialityImpact": "NONE",
"integrityImpact": "PARTIAL",
"vectorString": "AV:N/AC:M/Au:S/C:N/I:P/A:N",
"version": "2.0"
},
"exploitabilityScore": 6.8,
"impactScore": 2.9,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": true
}
],
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 4.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:U/C:N/I:H/A:N",
"version": "3.1"
},
"exploitabilityScore": 0.9,
"impactScore": 3.6,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2021-02-19T16:15:12.937",
"references": [
{
"source": "cybersecurity@se.com",
"tags": [
"Mitigation",
"Vendor Advisory"
],
"url": "https://www.se.com/ww/en/download/document/SEVD-2021-040-01/"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Mitigation",
"Vendor Advisory"
],
"url": "https://www.se.com/ww/en/download/document/SEVD-2021-040-01/"
}
],
"sourceIdentifier": "cybersecurity@se.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-352"
}
],
"source": "cybersecurity@se.com",
"type": "Secondary"
}
]
}
CERTFR-2021-AVI-096
Vulnerability from certfr_avis - Published: 2021-02-10 - Updated: 2021-02-10
De multiples vulnérabilités ont été découvertes dans les produits Schneider Electric. Elles permettent à un attaquant de provoquer un problème de sécurité non spécifié par l'éditeur et une atteinte à la confidentialité des données.
Solution
Se référer au bulletin de sécurité de l'éditeur pour l'obtention des correctifs (cf. section Documentation).
None| Vendor | Product | Description | ||
|---|---|---|---|---|
| Schneider Electric | N/A | ION9000 versions antérieures à 3.0.0 | ||
| Schneider Electric | N/A | ION7650 toutes versions | ||
| Schneider Electric | N/A | PM8000 versions antérieures à 3.0.0 | ||
| Schneider Electric | N/A | ION7400 versions antérieures à 3.0.0 | ||
| Schneider Electric | N/A | ION8650 versions 4.31.2 et antérieures | ||
| Schneider Electric | N/A | ION7700/73xx toutes versions | ||
| Schneider Electric | N/A | ION8800 toutes versions | ||
| Schneider Electric | N/A | ION83xx/84xx/85xx/8600 toutes versions |
| Title | Publication Time | Tags | |||
|---|---|---|---|---|---|
|
|||||
{
"$ref": "https://www.cert.ssi.gouv.fr/openapi.json",
"affected_systems": [
{
"description": "ION9000 versions ant\u00e9rieures \u00e0 3.0.0",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "ION7650 toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "PM8000 versions ant\u00e9rieures \u00e0 3.0.0",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "ION7400 versions ant\u00e9rieures \u00e0 3.0.0",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "ION8650 versions 4.31.2 et ant\u00e9rieures",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "ION7700/73xx toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "ION8800 toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "ION83xx/84xx/85xx/8600 toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
}
],
"affected_systems_content": null,
"content": "## Solution\n\nSe r\u00e9f\u00e9rer au bulletin de s\u00e9curit\u00e9 de l\u0027\u00e9diteur pour l\u0027obtention des\ncorrectifs (cf. section Documentation).\n",
"cves": [
{
"name": "CVE-2021-22703",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-22703"
},
{
"name": "CVE-2021-22701",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-22701"
},
{
"name": "CVE-2021-22702",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-22702"
}
],
"initial_release_date": "2021-02-10T00:00:00",
"last_revision_date": "2021-02-10T00:00:00",
"links": [],
"reference": "CERTFR-2021-AVI-096",
"revisions": [
{
"description": "Version initiale",
"revision_date": "2021-02-10T00:00:00.000000"
}
],
"risks": [
{
"description": "Non sp\u00e9cifi\u00e9 par l\u0027\u00e9diteur"
},
{
"description": "Atteinte \u00e0 la confidentialit\u00e9 des donn\u00e9es"
}
],
"summary": "De multiples vuln\u00e9rabilit\u00e9s ont \u00e9t\u00e9 d\u00e9couvertes dans les produits\nSchneider Electric. Elles permettent \u00e0 un attaquant de provoquer un\nprobl\u00e8me de s\u00e9curit\u00e9 non sp\u00e9cifi\u00e9 par l\u0027\u00e9diteur et une atteinte \u00e0 la\nconfidentialit\u00e9 des donn\u00e9es.\n",
"title": "Multiples vuln\u00e9rabilit\u00e9s dans les produits Schneider Electric",
"vendor_advisories": [
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider Electric SEVD-2021-040-01 du 09 f\u00e9vrier 2021",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-040-01"
}
]
}
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.