CVE-2021-22283 (GCVE-0-2021-22283)

Vulnerability from cvelistv5 – Published: 2023-02-28 04:21 – Updated: 2025-03-07 18:12
VLAI
Title
MMS File Transfer Vulnerability impact on Distribution Automation products
Summary
Improper Initialization vulnerability in ABB Relion protection relays - 611 series, ABB Relion protection relays - 615 series IEC 4.0 FP1, ABB Relion protection relays - 615 series CN 4.0 FP1, ABB Relion protection relays - 615 series IEC 5.0, ABB Relion protection relays - 615 series IEC 5.0 FP1, ABB Relion protection relays - 620 series IEC/CN 2.0, ABB Relion protection relays - 620 series IEC/CN 2.0 FP1, ABB Relion protection relays - REX640 PCL1, ABB Relion protection relays - REX640 PCL2, ABB Relion protection relays - REX640 PCL3, ABB Relion protection relays - RER615, ABB Remote Monitoring and Control - REC615, ABB Merging Unit- SMU615 allows Communication Channel Manipulation.This issue affects Relion protection relays - 611 series: from 1.0.0 before 2.0.3; Relion protection relays - 615 series IEC 4.0 FP1: from 4.1.0 before 4.1.9; Relion protection relays - 615 series CN 4.0 FP1: from 4.1.0 before 4.1.8; Relion protection relays - 615 series IEC 5.0: from 5.0.0 before 5.0.12; Relion protection relays - 615 series IEC 5.0 FP1: from 5.1.0 before 5.1.20; Relion protection relays - 620 series IEC/CN 2.0: from 2.0.0 before 2.0.11; Relion protection relays - 620 series IEC/CN 2.0 FP1: from 2.1.0 before 2.1.15; Relion protection relays - REX640 PCL1: from 1.0.0 before 1.0.8; Relion protection relays - REX640 PCL2: from 1.1.0 before 1.1.4; Relion protection relays - REX640 PCL3: from 1.2.0 before 1.2.1; Relion protection relays - RER615: from 2.0.0 before 2.0.3; Remote Monitoring and Control - REC615: from 1.0.0 before 2.0.3; Merging Unit- SMU615: from 1.0.0 before 1.0.2.
SSVC
Exploitation: none Automatable: no Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2025-03-07 18:11 UTC
CWE
  • CWE-665 - Improper Initialization
Assigner
ABB CNA under the icscert root
CNA scorecard C 68/100 over 16 records in the last 180 days details
Impacted products
Vendor Product Version CPE status
ABB Relion protection relays - 611 series Affected: 1.0.0 , < 2.0.3 (firmware)
guessed Create a notification for this product.
ABB Relion protection relays - 615 series IEC 4.0 FP1 Affected: 4.1.0 , < 4.1.9 (firmware)
guessed Create a notification for this product.
ABB Relion protection relays - 615 series CN 4.0 FP1 Affected: 4.1.0 , < 4.1.8 (firmware)
guessed Create a notification for this product.
ABB Relion protection relays - 615 series IEC 5.0 Affected: 5.0.0 , < 5.0.12 (firmware)
guessed Create a notification for this product.
ABB Relion protection relays - 615 series IEC 5.0 FP1 Affected: 5.1.0 , < 5.1.20 (firmware)
guessed Create a notification for this product.
ABB Relion protection relays - 620 series IEC/CN 2.0 Affected: 2.0.0 , < 2.0.11 (firmware)
guessed Create a notification for this product.
ABB Relion protection relays - 620 series IEC/CN 2.0 FP1 Affected: 2.1.0 , < 2.1.15 (firmware)
guessed Create a notification for this product.
ABB Relion protection relays - REX640 PCL1 Affected: 1.0.0 , < 1.0.8 (firmware)
guessed Create a notification for this product.
ABB Relion protection relays - REX640 PCL2 Affected: 1.1.0 , < 1.1.4 (firmware)
guessed Create a notification for this product.
ABB Relion protection relays - REX640 PCL3 Affected: 1.2.0 , < 1.2.1 (firmware)
guessed Create a notification for this product.
ABB Relion protection relays - RER615 Affected: 2.0.0 , < 2.0.3 (firmware)
guessed Create a notification for this product.
ABB Remote Monitoring and Control - REC615 Affected: 1.0.0 , < 2.0.3 (firmware)
guessed Create a notification for this product.
ABB Merging Unit- SMU615 Affected: 1.0.0 , < 1.0.2 (firmware)
guessed Create a notification for this product.
Date Public
2022-12-18 18:30
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T18:37:18.488Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://search.abb.com/library/Download.aspx?DocumentID=2NGA001147\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2021-22283",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-03-07T18:11:58.860932Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-03-07T18:12:14.516Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Relion protection relays - 611 series",
          "vendor": "ABB",
          "versions": [
            {
              "lessThan": "2.0.3",
              "status": "affected",
              "version": "1.0.0",
              "versionType": "firmware"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "Relion protection relays - 615 series IEC 4.0 FP1",
          "vendor": "ABB",
          "versions": [
            {
              "lessThan": " 4.1.9",
              "status": "affected",
              "version": "4.1.0",
              "versionType": "firmware"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "Relion protection relays - 615 series CN 4.0 FP1",
          "vendor": "ABB",
          "versions": [
            {
              "lessThan": "4.1.8",
              "status": "affected",
              "version": "4.1.0",
              "versionType": "firmware"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "Relion protection relays - 615 series IEC 5.0",
          "vendor": "ABB",
          "versions": [
            {
              "lessThan": "5.0.12",
              "status": "affected",
              "version": "5.0.0",
              "versionType": "firmware"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "Relion protection relays - 615 series IEC 5.0 FP1",
          "vendor": "ABB",
          "versions": [
            {
              "lessThan": "5.1.20",
              "status": "affected",
              "version": "5.1.0",
              "versionType": "firmware"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "Relion protection relays - 620 series IEC/CN 2.0",
          "vendor": "ABB",
          "versions": [
            {
              "lessThan": "2.0.11",
              "status": "affected",
              "version": "2.0.0",
              "versionType": "firmware"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "Relion protection relays - 620 series IEC/CN 2.0 FP1",
          "vendor": "ABB",
          "versions": [
            {
              "lessThan": "2.1.15",
              "status": "affected",
              "version": "2.1.0",
              "versionType": "firmware"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "Relion protection relays - REX640 PCL1",
          "vendor": "ABB",
          "versions": [
            {
              "lessThan": "1.0.8",
              "status": "affected",
              "version": "1.0.0",
              "versionType": "firmware"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "Relion protection relays - REX640 PCL2",
          "vendor": "ABB",
          "versions": [
            {
              "lessThan": "1.1.4",
              "status": "affected",
              "version": "1.1.0",
              "versionType": "firmware"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "Relion protection relays - REX640 PCL3",
          "vendor": "ABB",
          "versions": [
            {
              "lessThan": "1.2.1",
              "status": "affected",
              "version": "1.2.0",
              "versionType": "firmware"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "Relion protection relays - RER615",
          "vendor": "ABB",
          "versions": [
            {
              "lessThan": "2.0.3",
              "status": "affected",
              "version": "2.0.0",
              "versionType": "firmware"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "Remote Monitoring and Control - REC615",
          "vendor": "ABB",
          "versions": [
            {
              "lessThan": "2.0.3",
              "status": "affected",
              "version": "1.0.0",
              "versionType": "firmware"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "Merging Unit- SMU615",
          "vendor": "ABB",
          "versions": [
            {
              "lessThan": "1.0.2",
              "status": "affected",
              "version": "1.0.0",
              "versionType": "firmware"
            }
          ]
        }
      ],
      "datePublic": "2022-12-18T18:30:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Improper Initialization vulnerability in ABB Relion protection relays - 611 series, ABB Relion protection relays - 615 series IEC 4.0 FP1, ABB Relion protection relays - 615 series CN 4.0 FP1, ABB Relion protection relays - 615 series IEC 5.0, ABB Relion protection relays - 615 series IEC 5.0 FP1, ABB Relion protection relays - 620 series IEC/CN 2.0, ABB Relion protection relays - 620 series IEC/CN 2.0 FP1, ABB Relion protection relays - REX640 PCL1, ABB Relion protection relays - REX640 PCL2, ABB Relion protection relays - REX640 PCL3, ABB Relion protection relays - RER615, ABB Remote Monitoring and Control - REC615, ABB Merging Unit- SMU615 allows Communication Channel Manipulation.\u003cp\u003eThis issue affects Relion protection relays - 611 series: from 1.0.0 before 2.0.3; Relion protection relays - 615 series IEC 4.0 FP1: from 4.1.0 before 4.1.9; Relion protection relays - 615 series CN 4.0 FP1: from 4.1.0 before 4.1.8; Relion protection relays - 615 series IEC 5.0: from 5.0.0 before 5.0.12; Relion protection relays - 615 series IEC 5.0 FP1: from 5.1.0 before 5.1.20; Relion protection relays - 620 series IEC/CN 2.0: from 2.0.0 before 2.0.11; Relion protection relays - 620 series IEC/CN 2.0 FP1: from 2.1.0 before 2.1.15; Relion protection relays - REX640 PCL1: from 1.0.0 before 1.0.8; Relion protection relays - REX640 PCL2: from 1.1.0 before 1.1.4; Relion protection relays - REX640 PCL3: from 1.2.0 before 1.2.1; Relion protection relays - RER615: from 2.0.0 before 2.0.3; Remote Monitoring and Control - REC615: from 1.0.0 before 2.0.3; Merging Unit- SMU615: from 1.0.0 before 1.0.2.\u003c/p\u003e"
            }
          ],
          "value": "Improper Initialization vulnerability in ABB Relion protection relays - 611 series, ABB Relion protection relays - 615 series IEC 4.0 FP1, ABB Relion protection relays - 615 series CN 4.0 FP1, ABB Relion protection relays - 615 series IEC 5.0, ABB Relion protection relays - 615 series IEC 5.0 FP1, ABB Relion protection relays - 620 series IEC/CN 2.0, ABB Relion protection relays - 620 series IEC/CN 2.0 FP1, ABB Relion protection relays - REX640 PCL1, ABB Relion protection relays - REX640 PCL2, ABB Relion protection relays - REX640 PCL3, ABB Relion protection relays - RER615, ABB Remote Monitoring and Control - REC615, ABB Merging Unit- SMU615 allows Communication Channel Manipulation.This issue affects Relion protection relays - 611 series: from 1.0.0 before 2.0.3; Relion protection relays - 615 series IEC 4.0 FP1: from 4.1.0 before 4.1.9; Relion protection relays - 615 series CN 4.0 FP1: from 4.1.0 before 4.1.8; Relion protection relays - 615 series IEC 5.0: from 5.0.0 before 5.0.12; Relion protection relays - 615 series IEC 5.0 FP1: from 5.1.0 before 5.1.20; Relion protection relays - 620 series IEC/CN 2.0: from 2.0.0 before 2.0.11; Relion protection relays - 620 series IEC/CN 2.0 FP1: from 2.1.0 before 2.1.15; Relion protection relays - REX640 PCL1: from 1.0.0 before 1.0.8; Relion protection relays - REX640 PCL2: from 1.1.0 before 1.1.4; Relion protection relays - REX640 PCL3: from 1.2.0 before 1.2.1; Relion protection relays - RER615: from 2.0.0 before 2.0.3; Remote Monitoring and Control - REC615: from 1.0.0 before 2.0.3; Merging Unit- SMU615: from 1.0.0 before 1.0.2.\n\n"
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-216",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-216 Communication Channel Manipulation"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 6.2,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "NONE",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-665",
              "description": "CWE-665 Improper Initialization",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-02-28T04:21:41.776Z",
        "orgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
        "shortName": "ABB"
      },
      "references": [
        {
          "url": "https://search.abb.com/library/Download.aspx?DocumentID=2NGA001147\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "MMS File Transfer Vulnerability impact on Distribution Automation products",
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
    "assignerShortName": "ABB",
    "cveId": "CVE-2021-22283",
    "datePublished": "2023-02-28T04:21:41.776Z",
    "dateReserved": "2021-01-05T17:31:49.081Z",
    "dateUpdated": "2025-03-07T18:12:14.516Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "epss": {
      "cve": "CVE-2021-22283",
      "date": "2026-10-15",
      "epss": "0.00171",
      "percentile": "0.06022"
    },
    "nvd": {
      "cve": {
        "configurations": [
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:abb:smu615_firmware:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "C01EB90B-8C81-4745-91C2-62747B185AE3",
                    "versionEndExcluding": "1.0.2",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:abb:smu615:-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "F24FC432-A799-44A1-9D7C-BF02203655C5",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          },
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:abb:rec615_firmware:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "AEDB4A6F-2E61-4962-A3D5-350070435A3B",
                    "versionEndExcluding": "2.0.3",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:abb:rec615:-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "D5A61686-5740-48D4-AF7C-34F3323F4171",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          },
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:abb:rer615_firmware:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "8DBD6846-1876-4EB7-B450-23689D08D05C",
                    "versionEndExcluding": "2.0.3",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:abb:rer615:-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "F4FB1663-BA8D-4EDA-85D3-37FF05718FB7",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          },
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:abb:evd4_firmware:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "D151411F-BBA1-4CC1-A898-7922CE9C734C",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:abb:evd4:-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "EEA5D2E2-AA96-4C81-8979-744778F19CC0",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          },
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:abb:ref615r_firmware:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "5BB52A0A-144A-4701-A169-0DE203AF3733",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:abb:ref615r:-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "9C1A2F33-73B8-488B-A88C-3546CA9FB51D",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          },
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:abb:rex640_pcl3_firmware:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "E3973E21-DF2C-47BB-8C03-6FA027018873",
                    "versionEndExcluding": "1.2.1",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:abb:rex640_pcl3:-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "90916E18-27EF-46C7-979B-19D53F901CC7",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          },
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:abb:rex640_pcl2_firmware:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "FBE1B4D1-27C7-4EA9-ADA5-A7FE42E04FF6",
                    "versionEndExcluding": "1.1.4",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:abb:rex640_pcl2:-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "AE78102B-C672-4969-8B82-FE5ACE2FFC71",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          },
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:abb:rex640_pcl1_firmware:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "AAA125ED-192D-4E4E-A4FC-FB7EF387FD90",
                    "versionEndExcluding": "1.0.8",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:abb:rex640_pcl1:-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "9256FAAB-77CF-482C-B736-FC99885C89D7",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          },
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:abb:rer620_firmware:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "F8506D82-076A-4B42-AF41-CECE5B9F42A1",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:abb:rer620:-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "A0CDB660-57FB-4B12-B457-D32A20CB054D",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          },
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:abb:relion_611_firmware:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "F1D7EA08-4326-47EA-8045-135263708315",
                    "versionEndExcluding": "2.0.3",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:abb:relion_611:-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "7D0BD760-FCEA-4620-A8D9-407C4670BDA0",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          },
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:abb:ref615_iec_firmware:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "B53D526E-2EE7-4D50-B6AE-43A2E5F51902",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:abb:ref615_iec:1.0:*:*:*:*:*:*:*",
                    "matchCriteriaId": "9A52B165-B93A-4CD5-85F7-8DC085B8BF8D",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          },
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:abb:ref615_ansi_firmware:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "6B0493F4-7619-4D98-9D15-069ECAF34EA2",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:abb:ref615_ansi:1.0:*:*:*:*:*:*:*",
                    "matchCriteriaId": "27CE34F9-8441-4327-A7CF-BC9ED6C2838C",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          },
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:abb:ref615_iec_firmware:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "B53D526E-2EE7-4D50-B6AE-43A2E5F51902",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:abb:ref615_iec:1.1:*:*:*:*:*:*:*",
                    "matchCriteriaId": "5C694E31-330C-41B1-A080-278A1C3111A2",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          },
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:abb:red615_iec_firmware:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "D1375F21-B685-4CC8-B781-73D68B07DC5B",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:abb:red615_iec:1.1:*:*:*:*:*:*:*",
                    "matchCriteriaId": "B694B186-62A0-4235-97EB-EF4A9F02F185",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          },
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:abb:ref615_ansi_firmware:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "6B0493F4-7619-4D98-9D15-069ECAF34EA2",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:abb:ref615_ansi:1.1:*:*:*:*:*:*:*",
                    "matchCriteriaId": "A250B053-1FD7-44F1-8622-C6FDFF4DE575",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          },
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:abb:relion_615_iec_firmware:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "81982E5D-C2B7-40E5-B4B1-20E05558C183",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:abb:relion_615_iec:2.0:*:*:*:*:*:*:*",
                    "matchCriteriaId": "E98E9975-0978-4632-9202-A036A2D66C7F",
                    "vulnerable": false
                  },
                  {
                    "criteria": "cpe:2.3:h:abb:relion_615_iec:3.0:*:*:*:*:*:*:*",
                    "matchCriteriaId": "0954C681-0897-441F-AD78-2B1FBC6EC208",
                    "vulnerable": false
                  },
                  {
                    "criteria": "cpe:2.3:h:abb:relion_615_iec:4.0:-:*:*:*:*:*:*",
                    "matchCriteriaId": "D9C4BDD6-3EE7-4DC9-97C7-8F7F04DD80F8",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          },
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:abb:relion_615_cn_firmware:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "50CB9495-DBBC-4B36-AF67-6D5E1CD4CE76",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:abb:relion_615_cn:2.0:*:*:*:*:*:*:*",
                    "matchCriteriaId": "D2773068-653B-4F02-8CB8-5CA4CF7D6574",
                    "vulnerable": false
                  },
                  {
                    "criteria": "cpe:2.3:h:abb:relion_615_cn:3.0:*:*:*:*:*:*:*",
                    "matchCriteriaId": "66B405A7-E16B-48E0-AFC9-36A6AB21451D",
                    "vulnerable": false
                  },
                  {
                    "criteria": "cpe:2.3:h:abb:relion_615_cn:3.1:*:*:*:*:*:*:*",
                    "matchCriteriaId": "334CAC56-FBBC-45D4-9161-A53197CB30C2",
                    "vulnerable": false
                  },
                  {
                    "criteria": "cpe:2.3:h:abb:relion_615_cn:4.0:-:*:*:*:*:*:*",
                    "matchCriteriaId": "0B5B5511-A4EF-4814-BD67-F5A2F445B111",
                    "vulnerable": false
                  },
                  {
                    "criteria": "cpe:2.3:h:abb:relion_615_cn:5.0:fp1:*:*:*:*:*:*",
                    "matchCriteriaId": "431FDF0D-6734-40C0-AFA5-A5513B7324E6",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          },
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:abb:relion_615_ansi_firmware:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "78236AA2-3560-402B-B2FC-13070B805609",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:abb:relion_615_ansi:2.0:*:*:*:*:*:*:*",
                    "matchCriteriaId": "591DB01E-3610-4AD2-A5F9-D8A061B597A5",
                    "vulnerable": false
                  },
                  {
                    "criteria": "cpe:2.3:h:abb:relion_615_ansi:4.0:-:*:*:*:*:*:*",
                    "matchCriteriaId": "63988EAE-73F9-4362-8B38-EDC3B1207F0F",
                    "vulnerable": false
                  },
                  {
                    "criteria": "cpe:2.3:h:abb:relion_615_ansi:4.0:fp1:*:*:*:*:*:*",
                    "matchCriteriaId": "05EF9495-C9B5-40C6-B648-C85B35373023",
                    "vulnerable": false
                  },
                  {
                    "criteria": "cpe:2.3:h:abb:relion_615_ansi:4.0:fp2:*:*:*:*:*:*",
                    "matchCriteriaId": "0208F75C-011B-4A15-AD1B-8DD1550B3077",
                    "vulnerable": false
                  },
                  {
                    "criteria": "cpe:2.3:h:abb:relion_615_ansi:5.0:fp1:*:*:*:*:*:*",
                    "matchCriteriaId": "8B25AD70-B3B4-45A7-B4B6-E072BA0A336A",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          },
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:abb:relion_615_iec_firmware:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "C79758CF-9F3B-4A79-A8D4-3D17D5D85497",
                    "versionEndExcluding": "4.1.9",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:abb:relion_615_iec:4.0:fp1:*:*:*:*:*:*",
                    "matchCriteriaId": "A6E38E09-2B98-4B3A-BFC0-391DE22ABDE9",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          },
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:abb:relion_615_cn_firmware:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "79918D6E-7694-43B2-B474-649174A00054",
                    "versionEndExcluding": "4.1.8",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:abb:relion_615_cn:4.0:fp1:*:*:*:*:*:*",
                    "matchCriteriaId": "412F7432-5049-4DB0-8009-6783A3821F1F",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          },
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:abb:relion_615_iec_firmware:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "3FE9A6FF-BBFD-48D6-B9D2-3AD244221C20",
                    "versionEndExcluding": "5.0.12",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:abb:relion_615_iec:5.0:-:*:*:*:*:*:*",
                    "matchCriteriaId": "DE999A72-CEED-4235-B68F-590CF1128268",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          },
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:abb:relion_615_iec_firmware:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "47DB1FAF-07D7-44FD-8368-BB29FF0DB4AD",
                    "versionEndExcluding": "5.1.20",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:abb:relion_615_iec:5.0:fp1:*:*:*:*:*:*",
                    "matchCriteriaId": "50330FD9-AA32-439B-9E06-7228A7338F46",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          },
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:abb:relion_620_iec_firmware:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "F5E4CADD-7849-40B5-9DC6-8B0571A5B16E",
                    "versionEndExcluding": "2.0.11",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:abb:relion_620_iec:2.0:-:*:*:*:*:*:*",
                    "matchCriteriaId": "91122A2B-236D-4D36-93BD-93A6C2DB0263",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          },
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:abb:relion_620_cn_firmware:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "C7230BC1-056F-4E13-AA11-8B19AC404B71",
                    "versionEndExcluding": "2.0.11",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:abb:relion_620_cn:2.0:-:*:*:*:*:*:*",
                    "matchCriteriaId": "281A30D2-94DA-4D19-AAA7-30061BD94443",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          },
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:abb:relion_620_ansi_firmware:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "AD99BDB2-6F9C-4141-AE1E-919764CD000A",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:abb:relion_620_ansi:-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "2A89CD0B-3990-47B0-9129-2BD5951F8C9B",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          },
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:abb:relion_620_iec_firmware:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "315BBD9A-D5ED-4864-B12D-1C95515E7818",
                    "versionEndExcluding": "2.1.15",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:abb:relion_620_iec:2.0:fp1:*:*:*:*:*:*",
                    "matchCriteriaId": "CD43DF9B-4D26-4B59-BADA-F333D7E2815D",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          },
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:abb:relion_620_cn_firmware:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "0BEA650E-EFD1-445D-8022-5C512E98B485",
                    "versionEndExcluding": "2.1.15",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:abb:relion_620_cn:2.0:fp1:*:*:*:*:*:*",
                    "matchCriteriaId": "806460AF-BC4A-4584-8172-20092865AEEF",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          }
        ],
        "cveTags": [],
        "descriptions": [
          {
            "lang": "en",
            "value": "Improper Initialization vulnerability in ABB Relion protection relays - 611 series, ABB Relion protection relays - 615 series IEC 4.0 FP1, ABB Relion protection relays - 615 series CN 4.0 FP1, ABB Relion protection relays - 615 series IEC 5.0, ABB Relion protection relays - 615 series IEC 5.0 FP1, ABB Relion protection relays - 620 series IEC/CN 2.0, ABB Relion protection relays - 620 series IEC/CN 2.0 FP1, ABB Relion protection relays - REX640 PCL1, ABB Relion protection relays - REX640 PCL2, ABB Relion protection relays - REX640 PCL3, ABB Relion protection relays - RER615, ABB Remote Monitoring and Control - REC615, ABB Merging Unit- SMU615 allows Communication Channel Manipulation.This issue affects Relion protection relays - 611 series: from 1.0.0 before 2.0.3; Relion protection relays - 615 series IEC 4.0 FP1: from 4.1.0 before 4.1.9; Relion protection relays - 615 series CN 4.0 FP1: from 4.1.0 before 4.1.8; Relion protection relays - 615 series IEC 5.0: from 5.0.0 before 5.0.12; Relion protection relays - 615 series IEC 5.0 FP1: from 5.1.0 before 5.1.20; Relion protection relays - 620 series IEC/CN 2.0: from 2.0.0 before 2.0.11; Relion protection relays - 620 series IEC/CN 2.0 FP1: from 2.1.0 before 2.1.15; Relion protection relays - REX640 PCL1: from 1.0.0 before 1.0.8; Relion protection relays - REX640 PCL2: from 1.1.0 before 1.1.4; Relion protection relays - REX640 PCL3: from 1.2.0 before 1.2.1; Relion protection relays - RER615: from 2.0.0 before 2.0.3; Remote Monitoring and Control - REC615: from 1.0.0 before 2.0.3; Merging Unit- SMU615: from 1.0.0 before 1.0.2.\n\n"
          }
        ],
        "id": "CVE-2021-22283",
        "lastModified": "2024-11-21T05:49:50.640",
        "metrics": {
          "cvssMetricV31": [
            {
              "cvssData": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "HIGH",
                "baseScore": 6.2,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "NONE",
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
                "version": "3.1"
              },
              "exploitabilityScore": 2.5,
              "impactScore": 3.6,
              "source": "cybersecurity@ch.abb.com",
              "type": "Secondary"
            },
            {
              "cvssData": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "HIGH",
                "baseScore": 5.5,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "NONE",
                "integrityImpact": "NONE",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
                "version": "3.1"
              },
              "exploitabilityScore": 1.8,
              "impactScore": 3.6,
              "source": "nvd@nist.gov",
              "type": "Primary"
            }
          ]
        },
        "published": "2023-02-28T05:15:12.260",
        "references": [
          {
            "source": "cybersecurity@ch.abb.com",
            "tags": [
              "Vendor Advisory"
            ],
            "url": "https://search.abb.com/library/Download.aspx?DocumentID=2NGA001147\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
          },
          {
            "source": "af854a3a-2127-422b-91ae-364da2661108",
            "tags": [
              "Vendor Advisory"
            ],
            "url": "https://search.abb.com/library/Download.aspx?DocumentID=2NGA001147\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
          }
        ],
        "sourceIdentifier": "cybersecurity@ch.abb.com",
        "vulnStatus": "Modified",
        "weaknesses": [
          {
            "description": [
              {
                "lang": "en",
                "value": "CWE-665"
              }
            ],
            "source": "cybersecurity@ch.abb.com",
            "type": "Secondary"
          },
          {
            "description": [
              {
                "lang": "en",
                "value": "CWE-665"
              }
            ],
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ]
      }
    },
    "redhat_vex": {
      "current_release_date": "2026-01-09T09:18:39+00:00",
      "cve": "CVE-2021-22283",
      "id": "CVE-2021-22283",
      "initial_release_date": "2021-01-01T00:00:00+00:00",
      "product_status:known_not_affected": "1",
      "source": "Red Hat CSAF VEX",
      "status": "final",
      "title": "MMS File Transfer Vulnerability impact on Distribution Automation products",
      "url": "https://security.access.redhat.com/data/csaf/v2/vex/2021/cve-2021-22283.json",
      "version": "3"
    },
    "vulnrichment": {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T18:37:18.488Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://search.abb.com/library/Download.aspx?DocumentID=2NGA001147\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2021-22283",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-03-07T18:11:58.860932Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-03-07T18:12:09.280Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "Relion protection relays - 611 series",
              "vendor": "ABB",
              "versions": [
                {
                  "lessThan": "2.0.3",
                  "status": "affected",
                  "version": "1.0.0",
                  "versionType": "firmware"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Relion protection relays - 615 series IEC 4.0 FP1",
              "vendor": "ABB",
              "versions": [
                {
                  "lessThan": " 4.1.9",
                  "status": "affected",
                  "version": "4.1.0",
                  "versionType": "firmware"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Relion protection relays - 615 series CN 4.0 FP1",
              "vendor": "ABB",
              "versions": [
                {
                  "lessThan": "4.1.8",
                  "status": "affected",
                  "version": "4.1.0",
                  "versionType": "firmware"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Relion protection relays - 615 series IEC 5.0",
              "vendor": "ABB",
              "versions": [
                {
                  "lessThan": "5.0.12",
                  "status": "affected",
                  "version": "5.0.0",
                  "versionType": "firmware"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Relion protection relays - 615 series IEC 5.0 FP1",
              "vendor": "ABB",
              "versions": [
                {
                  "lessThan": "5.1.20",
                  "status": "affected",
                  "version": "5.1.0",
                  "versionType": "firmware"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Relion protection relays - 620 series IEC/CN 2.0",
              "vendor": "ABB",
              "versions": [
                {
                  "lessThan": "2.0.11",
                  "status": "affected",
                  "version": "2.0.0",
                  "versionType": "firmware"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Relion protection relays - 620 series IEC/CN 2.0 FP1",
              "vendor": "ABB",
              "versions": [
                {
                  "lessThan": "2.1.15",
                  "status": "affected",
                  "version": "2.1.0",
                  "versionType": "firmware"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Relion protection relays - REX640 PCL1",
              "vendor": "ABB",
              "versions": [
                {
                  "lessThan": "1.0.8",
                  "status": "affected",
                  "version": "1.0.0",
                  "versionType": "firmware"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Relion protection relays - REX640 PCL2",
              "vendor": "ABB",
              "versions": [
                {
                  "lessThan": "1.1.4",
                  "status": "affected",
                  "version": "1.1.0",
                  "versionType": "firmware"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Relion protection relays - REX640 PCL3",
              "vendor": "ABB",
              "versions": [
                {
                  "lessThan": "1.2.1",
                  "status": "affected",
                  "version": "1.2.0",
                  "versionType": "firmware"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Relion protection relays - RER615",
              "vendor": "ABB",
              "versions": [
                {
                  "lessThan": "2.0.3",
                  "status": "affected",
                  "version": "2.0.0",
                  "versionType": "firmware"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Remote Monitoring and Control - REC615",
              "vendor": "ABB",
              "versions": [
                {
                  "lessThan": "2.0.3",
                  "status": "affected",
                  "version": "1.0.0",
                  "versionType": "firmware"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Merging Unit- SMU615",
              "vendor": "ABB",
              "versions": [
                {
                  "lessThan": "1.0.2",
                  "status": "affected",
                  "version": "1.0.0",
                  "versionType": "firmware"
                }
              ]
            }
          ],
          "datePublic": "2022-12-18T18:30:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Improper Initialization vulnerability in ABB Relion protection relays - 611 series, ABB Relion protection relays - 615 series IEC 4.0 FP1, ABB Relion protection relays - 615 series CN 4.0 FP1, ABB Relion protection relays - 615 series IEC 5.0, ABB Relion protection relays - 615 series IEC 5.0 FP1, ABB Relion protection relays - 620 series IEC/CN 2.0, ABB Relion protection relays - 620 series IEC/CN 2.0 FP1, ABB Relion protection relays - REX640 PCL1, ABB Relion protection relays - REX640 PCL2, ABB Relion protection relays - REX640 PCL3, ABB Relion protection relays - RER615, ABB Remote Monitoring and Control - REC615, ABB Merging Unit- SMU615 allows Communication Channel Manipulation.\u003cp\u003eThis issue affects Relion protection relays - 611 series: from 1.0.0 before 2.0.3; Relion protection relays - 615 series IEC 4.0 FP1: from 4.1.0 before 4.1.9; Relion protection relays - 615 series CN 4.0 FP1: from 4.1.0 before 4.1.8; Relion protection relays - 615 series IEC 5.0: from 5.0.0 before 5.0.12; Relion protection relays - 615 series IEC 5.0 FP1: from 5.1.0 before 5.1.20; Relion protection relays - 620 series IEC/CN 2.0: from 2.0.0 before 2.0.11; Relion protection relays - 620 series IEC/CN 2.0 FP1: from 2.1.0 before 2.1.15; Relion protection relays - REX640 PCL1: from 1.0.0 before 1.0.8; Relion protection relays - REX640 PCL2: from 1.1.0 before 1.1.4; Relion protection relays - REX640 PCL3: from 1.2.0 before 1.2.1; Relion protection relays - RER615: from 2.0.0 before 2.0.3; Remote Monitoring and Control - REC615: from 1.0.0 before 2.0.3; Merging Unit- SMU615: from 1.0.0 before 1.0.2.\u003c/p\u003e"
                }
              ],
              "value": "Improper Initialization vulnerability in ABB Relion protection relays - 611 series, ABB Relion protection relays - 615 series IEC 4.0 FP1, ABB Relion protection relays - 615 series CN 4.0 FP1, ABB Relion protection relays - 615 series IEC 5.0, ABB Relion protection relays - 615 series IEC 5.0 FP1, ABB Relion protection relays - 620 series IEC/CN 2.0, ABB Relion protection relays - 620 series IEC/CN 2.0 FP1, ABB Relion protection relays - REX640 PCL1, ABB Relion protection relays - REX640 PCL2, ABB Relion protection relays - REX640 PCL3, ABB Relion protection relays - RER615, ABB Remote Monitoring and Control - REC615, ABB Merging Unit- SMU615 allows Communication Channel Manipulation.This issue affects Relion protection relays - 611 series: from 1.0.0 before 2.0.3; Relion protection relays - 615 series IEC 4.0 FP1: from 4.1.0 before 4.1.9; Relion protection relays - 615 series CN 4.0 FP1: from 4.1.0 before 4.1.8; Relion protection relays - 615 series IEC 5.0: from 5.0.0 before 5.0.12; Relion protection relays - 615 series IEC 5.0 FP1: from 5.1.0 before 5.1.20; Relion protection relays - 620 series IEC/CN 2.0: from 2.0.0 before 2.0.11; Relion protection relays - 620 series IEC/CN 2.0 FP1: from 2.1.0 before 2.1.15; Relion protection relays - REX640 PCL1: from 1.0.0 before 1.0.8; Relion protection relays - REX640 PCL2: from 1.1.0 before 1.1.4; Relion protection relays - REX640 PCL3: from 1.2.0 before 1.2.1; Relion protection relays - RER615: from 2.0.0 before 2.0.3; Remote Monitoring and Control - REC615: from 1.0.0 before 2.0.3; Merging Unit- SMU615: from 1.0.0 before 1.0.2.\n\n"
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-216",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-216 Communication Channel Manipulation"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "HIGH",
                "baseScore": 6.2,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "NONE",
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-665",
                  "description": "CWE-665 Improper Initialization",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2023-02-28T04:21:41.776Z",
            "orgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
            "shortName": "ABB"
          },
          "references": [
            {
              "url": "https://search.abb.com/library/Download.aspx?DocumentID=2NGA001147\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": "MMS File Transfer Vulnerability impact on Distribution Automation products",
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
        "assignerShortName": "ABB",
        "cveId": "CVE-2021-22283",
        "datePublished": "2023-02-28T04:21:41.776Z",
        "dateReserved": "2021-01-05T17:31:49.081Z",
        "dateUpdated": "2025-03-07T18:12:14.516Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }
  }
}



Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Drag nodes to arrange them. Double-click a related vulnerability to open it, or a source to visit its link. The Physics button on the left tunes the layout and the simulation; the legend at the bottom left hides or shows nodes by kind and by sighting type.

Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Vulnerability timeline

Sightings and recorded dates, grouped by day · UTC

JSON
Events included in the timeline

Loading timeline…


    Loading…

    Loading…

    Loading…

    Related by attack behaviour

    Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.