CVE-2020-7381 (GCVE-0-2020-7381)
Vulnerability from cvelistv5 – Published: 2020-09-03 13:55 – Updated: 2024-08-04 09:25
VLAI?
Title
Code Injection in Rapid7 Nexpose Installer
Summary
In Rapid7 Nexpose installer versions prior to 6.6.40, the Nexpose installer calls an executable which can be placed in the appropriate directory by an attacker with access to the local machine. This would prevent the installer from distinguishing between a valid executable called during a Security Console installation and any arbitrary code executable using the same file name.
Severity ?
5.8 (Medium)
CWE
- CWE-94 - Improper Control of Generation of Code ('Code Injection')
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Credits
This issue was discovered and reported by Mishra Dhiraj.
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T09:25:49.053Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://help.rapid7.com/insightvm/en-us/release-notes/index.html?pid=6.6.40"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Nexpose",
"vendor": "Rapid7",
"versions": [
{
"lessThan": "6.6.40",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"value": "This issue was discovered and reported by Mishra Dhiraj. "
}
],
"descriptions": [
{
"lang": "en",
"value": "In Rapid7 Nexpose installer versions prior to 6.6.40, the Nexpose installer calls an executable which can be placed in the appropriate directory by an attacker with access to the local machine. This would prevent the installer from distinguishing between a valid executable called during a Security Console installation and any arbitrary code executable using the same file name."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "LOCAL",
"availabilityImpact": "LOW",
"baseScore": 5.8,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:H/PR:H/UI:R/S:U/C:H/I:H/A:L",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-94",
"description": "CWE-94 Improper Control of Generation of Code (\u0027Code Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-09-03T13:55:25",
"orgId": "9974b330-7714-4307-a722-5648477acda7",
"shortName": "rapid7"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://help.rapid7.com/insightvm/en-us/release-notes/index.html?pid=6.6.40"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "Code Injection in Rapid7 Nexpose Installer",
"x_generator": {
"engine": "Vulnogram 0.0.9"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@rapid7.com",
"ID": "CVE-2020-7381",
"STATE": "PUBLIC",
"TITLE": "Code Injection in Rapid7 Nexpose Installer"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Nexpose",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_value": "6.6.40"
}
]
}
}
]
},
"vendor_name": "Rapid7"
}
]
}
},
"credit": [
{
"lang": "eng",
"value": "This issue was discovered and reported by Mishra Dhiraj. "
}
],
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "In Rapid7 Nexpose installer versions prior to 6.6.40, the Nexpose installer calls an executable which can be placed in the appropriate directory by an attacker with access to the local machine. This would prevent the installer from distinguishing between a valid executable called during a Security Console installation and any arbitrary code executable using the same file name."
}
]
},
"generator": {
"engine": "Vulnogram 0.0.9"
},
"impact": {
"cvss": {
"attackComplexity": "HIGH",
"attackVector": "LOCAL",
"availabilityImpact": "LOW",
"baseScore": 5.8,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:H/PR:H/UI:R/S:U/C:H/I:H/A:L",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-94 Improper Control of Generation of Code (\u0027Code Injection\u0027)"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://help.rapid7.com/insightvm/en-us/release-notes/index.html?pid=6.6.40",
"refsource": "MISC",
"url": "https://help.rapid7.com/insightvm/en-us/release-notes/index.html?pid=6.6.40"
}
]
},
"source": {
"discovery": "UNKNOWN"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "9974b330-7714-4307-a722-5648477acda7",
"assignerShortName": "rapid7",
"cveId": "CVE-2020-7381",
"datePublished": "2020-09-03T13:55:25",
"dateReserved": "2020-01-21T00:00:00",
"dateUpdated": "2024-08-04T09:25:49.053Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"nvd": "{\"cve\":{\"id\":\"CVE-2020-7381\",\"sourceIdentifier\":\"cve@rapid7.com\",\"published\":\"2020-09-03T14:15:10.977\",\"lastModified\":\"2024-11-21T05:37:08.257\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"In Rapid7 Nexpose installer versions prior to 6.6.40, the Nexpose installer calls an executable which can be placed in the appropriate directory by an attacker with access to the local machine. This would prevent the installer from distinguishing between a valid executable called during a Security Console installation and any arbitrary code executable using the same file name.\"},{\"lang\":\"es\",\"value\":\"En el instalador de Rapid7 Nexpose versiones anteriores a 6.6.40, el instalador de Nexpose llama un ejecutable que puede ser colocado por un atacante en el directorio apropiado con acceso a la m\u00e1quina local.\u0026#xa0;Esto impedir\u00eda que el instalador distinga entre un ejecutable v\u00e1lido llamado durante una instalaci\u00f3n de Security Console y cualquier c\u00f3digo arbitrario ejecutable usando el mismo nombre de archivo\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"cve@rapid7.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:L/AC:H/PR:H/UI:R/S:U/C:H/I:H/A:L\",\"baseScore\":5.8,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"HIGH\",\"privilegesRequired\":\"HIGH\",\"userInteraction\":\"REQUIRED\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"LOW\"},\"exploitabilityScore\":0.3,\"impactScore\":5.5},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H\",\"baseScore\":7.8,\"baseSeverity\":\"HIGH\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"REQUIRED\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":1.8,\"impactScore\":5.9}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:M/Au:N/C:P/I:P/A:P\",\"baseScore\":6.8,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"MEDIUM\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"PARTIAL\",\"integrityImpact\":\"PARTIAL\",\"availabilityImpact\":\"PARTIAL\"},\"baseSeverity\":\"MEDIUM\",\"exploitabilityScore\":8.6,\"impactScore\":6.4,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":true}]},\"weaknesses\":[{\"source\":\"cve@rapid7.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-94\"}]},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-94\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:rapid7:nexpose:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"6.6.40\",\"matchCriteriaId\":\"C3F6D1B0-EBA8-49AF-85E7-5D38810610F3\"}]}]}],\"references\":[{\"url\":\"https://help.rapid7.com/insightvm/en-us/release-notes/index.html?pid=6.6.40\",\"source\":\"cve@rapid7.com\",\"tags\":[\"Release Notes\",\"Vendor Advisory\"]},{\"url\":\"https://help.rapid7.com/insightvm/en-us/release-notes/index.html?pid=6.6.40\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Release Notes\",\"Vendor Advisory\"]}]}}"
}
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…