CVE-2020-3477 (GCVE-0-2020-3477)

Vulnerability from cvelistv5 – Published: 2020-09-24 17:52 – Updated: 2024-11-13 17:58
VLAI
Title
Cisco IOS and IOS XE Software Information Disclosure Vulnerability
Summary
A vulnerability in the CLI parser of Cisco IOS Software and Cisco IOS XE Software could allow an authenticated, local attacker to access files from the flash: filesystem. The vulnerability is due to insufficient application of restrictions during the execution of a specific command. An attacker could exploit this vulnerability by using a specific command at the command line. A successful exploit could allow the attacker to obtain read-only access to files that are located on the flash: filesystem that otherwise might not have been accessible.
SSVC
Exploitation: none Automatable: no Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2024-11-13 17:23 UTC
CWE
References
URL Tags
https://tools.cisco.com/security/center/content/C… vendor-advisoryx_refsource_CISCO
Impacted products
Vendor Product Version CPE status
Cisco Cisco IOS Affected: n/a
guessed Create a notification for this product.
Date Public
2020-09-24 00:00
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T07:37:54.308Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "20200924 Cisco IOS and IOS XE Software Information Disclosure Vulnerability",
            "tags": [
              "vendor-advisory",
              "x_refsource_CISCO",
              "x_transferred"
            ],
            "url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-info-disclosure-V4BmJBNF"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2020-3477",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-11-13T17:23:19.644914Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-11-13T17:58:01.086Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Cisco IOS",
          "vendor": "Cisco",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "datePublic": "2020-09-24T00:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability in the CLI parser of Cisco IOS Software and Cisco IOS XE Software could allow an authenticated, local attacker to access files from the flash: filesystem. The vulnerability is due to insufficient application of restrictions during the execution of a specific command. An attacker could exploit this vulnerability by using a specific command at the command line. A successful exploit could allow the attacker to obtain read-only access to files that are located on the flash: filesystem that otherwise might not have been accessible."
        }
      ],
      "exploits": [
        {
          "lang": "en",
          "value": "The Cisco Product Security Incident Response Team (PSIRT) is not aware of any public announcements or malicious use of the vulnerability that is described in this advisory."
        }
      ],
      "metrics": [
        {
          "cvssV3_0": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "NONE",
            "baseScore": 5.5,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "NONE",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N",
            "version": "3.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-20",
              "description": "CWE-20",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2020-09-24T17:52:48.000Z",
        "orgId": "d1c1063e-7a18-46af-9102-31f8928bc633",
        "shortName": "cisco"
      },
      "references": [
        {
          "name": "20200924 Cisco IOS and IOS XE Software Information Disclosure Vulnerability",
          "tags": [
            "vendor-advisory",
            "x_refsource_CISCO"
          ],
          "url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-info-disclosure-V4BmJBNF"
        }
      ],
      "source": {
        "advisory": "cisco-sa-info-disclosure-V4BmJBNF",
        "defect": [
          [
            "CSCvu10399"
          ]
        ],
        "discovery": "INTERNAL"
      },
      "title": "Cisco IOS and IOS XE Software Information Disclosure Vulnerability",
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "psirt@cisco.com",
          "DATE_PUBLIC": "2020-09-24T16:00:00",
          "ID": "CVE-2020-3477",
          "STATE": "PUBLIC",
          "TITLE": "Cisco IOS and IOS XE Software Information Disclosure Vulnerability"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Cisco IOS",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Cisco"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A vulnerability in the CLI parser of Cisco IOS Software and Cisco IOS XE Software could allow an authenticated, local attacker to access files from the flash: filesystem. The vulnerability is due to insufficient application of restrictions during the execution of a specific command. An attacker could exploit this vulnerability by using a specific command at the command line. A successful exploit could allow the attacker to obtain read-only access to files that are located on the flash: filesystem that otherwise might not have been accessible."
            }
          ]
        },
        "exploit": [
          {
            "lang": "en",
            "value": "The Cisco Product Security Incident Response Team (PSIRT) is not aware of any public announcements or malicious use of the vulnerability that is described in this advisory."
          }
        ],
        "impact": {
          "cvss": {
            "baseScore": "5.5",
            "vectorString": "CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N",
            "version": "3.0"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-20"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "20200924 Cisco IOS and IOS XE Software Information Disclosure Vulnerability",
              "refsource": "CISCO",
              "url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-info-disclosure-V4BmJBNF"
            }
          ]
        },
        "source": {
          "advisory": "cisco-sa-info-disclosure-V4BmJBNF",
          "defect": [
            [
              "CSCvu10399"
            ]
          ],
          "discovery": "INTERNAL"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "d1c1063e-7a18-46af-9102-31f8928bc633",
    "assignerShortName": "cisco",
    "cveId": "CVE-2020-3477",
    "datePublished": "2020-09-24T17:52:48.475Z",
    "dateReserved": "2019-12-12T00:00:00.000Z",
    "dateUpdated": "2024-11-13T17:58:01.086Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "epss": {
      "cve": "CVE-2020-3477",
      "date": "2026-09-22",
      "epss": "0.00324",
      "percentile": "0.25732"
    },
    "nvd": {
      "cve": {
        "configurations": [
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:cisco:ios:16.3.11:*:*:*:*:*:*:*",
                    "matchCriteriaId": "AAA3919B-5067-4451-9109-3A52C380BCAA",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:cisco:2610xm:-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "9E9B9F16-2D70-4109-999F-6A10D82DD68D",
                    "vulnerable": false
                  },
                  {
                    "criteria": "cpe:2.3:h:cisco:2611xm:-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "F77581A8-F334-445E-978C-D57F5135830B",
                    "vulnerable": false
                  },
                  {
                    "criteria": "cpe:2.3:h:cisco:2612:-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "E22D6ADA-DC1D-4916-9039-D0970727DE46",
                    "vulnerable": false
                  },
                  {
                    "criteria": "cpe:2.3:h:cisco:2620xm:-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "0CF86B51-A53D-4B3A-89B6-BFF3D40397B6",
                    "vulnerable": false
                  },
                  {
                    "criteria": "cpe:2.3:h:cisco:2621xm:-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "83F5E77F-E325-472B-AD80-98B2C2DBF0AB",
                    "vulnerable": false
                  },
                  {
                    "criteria": "cpe:2.3:h:cisco:2650xm:-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "E997D0D5-5436-4E39-8032-F6EA5DA45340",
                    "vulnerable": false
                  },
                  {
                    "criteria": "cpe:2.3:h:cisco:2651xm:-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "EF18B92D-D063-4D98-8D59-5AF02443DC4E",
                    "vulnerable": false
                  },
                  {
                    "criteria": "cpe:2.3:h:cisco:2691:-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "5F4063DC-7653-4777-B012-C49CCDD0E0B5",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          }
        ],
        "cveTags": [],
        "descriptions": [
          {
            "lang": "en",
            "value": "A vulnerability in the CLI parser of Cisco IOS Software and Cisco IOS XE Software could allow an authenticated, local attacker to access files from the flash: filesystem. The vulnerability is due to insufficient application of restrictions during the execution of a specific command. An attacker could exploit this vulnerability by using a specific command at the command line. A successful exploit could allow the attacker to obtain read-only access to files that are located on the flash: filesystem that otherwise might not have been accessible."
          },
          {
            "lang": "es",
            "value": "Una vulnerabilidad en el analizador de la CLI de Cisco IOS Software y Cisco IOS XE Software, podr\u00eda permitir a un atacante local autenticado acceder a archivos desde la flash: filesystem.\u0026#xa0;La vulnerabilidad es debido a una aplicaci\u00f3n insuficiente de restricciones durante la ejecuci\u00f3n de un comando espec\u00edfico.\u0026#xa0;Un atacante podr\u00eda explotar esta vulnerabilidad mediante el uso de un comando espec\u00edfico en la l\u00ednea de comandos.\u0026#xa0;Una explotaci\u00f3n con \u00e9xito podr\u00eda permitir al atacante conseguir acceso de solo lectura a archivos que est\u00e1n ubicados en la flash: filesystem que de otro modo no podr\u00eda haber sido accesible."
          }
        ],
        "id": "CVE-2020-3477",
        "lastModified": "2024-11-21T05:31:08.990",
        "metrics": {
          "cvssMetricV2": [
            {
              "acInsufInfo": false,
              "baseSeverity": "LOW",
              "cvssData": {
                "accessComplexity": "LOW",
                "accessVector": "LOCAL",
                "authentication": "NONE",
                "availabilityImpact": "NONE",
                "baseScore": 2.1,
                "confidentialityImpact": "PARTIAL",
                "integrityImpact": "NONE",
                "vectorString": "AV:L/AC:L/Au:N/C:P/I:N/A:N",
                "version": "2.0"
              },
              "exploitabilityScore": 3.9,
              "impactScore": 2.9,
              "obtainAllPrivilege": false,
              "obtainOtherPrivilege": false,
              "obtainUserPrivilege": false,
              "source": "nvd@nist.gov",
              "type": "Primary",
              "userInteractionRequired": false
            }
          ],
          "cvssMetricV30": [
            {
              "cvssData": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "NONE",
                "baseScore": 5.5,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "NONE",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N",
                "version": "3.0"
              },
              "exploitabilityScore": 1.8,
              "impactScore": 3.6,
              "source": "psirt@cisco.com",
              "type": "Secondary"
            }
          ],
          "cvssMetricV31": [
            {
              "cvssData": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "NONE",
                "baseScore": 5.5,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "NONE",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N",
                "version": "3.1"
              },
              "exploitabilityScore": 1.8,
              "impactScore": 3.6,
              "source": "nvd@nist.gov",
              "type": "Primary"
            }
          ]
        },
        "published": "2020-09-24T18:15:19.917",
        "references": [
          {
            "source": "psirt@cisco.com",
            "tags": [
              "Vendor Advisory"
            ],
            "url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-info-disclosure-V4BmJBNF"
          },
          {
            "source": "af854a3a-2127-422b-91ae-364da2661108",
            "tags": [
              "Vendor Advisory"
            ],
            "url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-info-disclosure-V4BmJBNF"
          }
        ],
        "sourceIdentifier": "psirt@cisco.com",
        "vulnStatus": "Modified",
        "weaknesses": [
          {
            "description": [
              {
                "lang": "en",
                "value": "CWE-20"
              }
            ],
            "source": "psirt@cisco.com",
            "type": "Secondary"
          },
          {
            "description": [
              {
                "lang": "en",
                "value": "CWE-863"
              }
            ],
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ]
      }
    }
  }
}



Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.

Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…

Related by attack behaviour

Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.


Loading…