Action not permitted
Modal body text goes here.
Modal Title
Modal Body
CVE-2020-24568 (GCVE-0-2020-24568)
Vulnerability from cvelistv5 – Published: 2020-10-02 18:19 – Updated: 2024-08-04 15:19- n/a
| URL | Tags |
|---|---|
| https://mbconnectline.com/security-advice/ | x_refsource_CONFIRM |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T15:19:09.015Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://mbconnectline.com/security-advice/"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "An issue was discovered in MB CONNECT LINE mymbCONNECT24 and mbCONNECT24 through 2.6.1. There is a blind SQL injection in the lancompenent component, allowing logged-in attackers to discover arbitrary information."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-10-02T18:20:39.000Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://mbconnectline.com/security-advice/"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2020-24568",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "An issue was discovered in MB CONNECT LINE mymbCONNECT24 and mbCONNECT24 through 2.6.1. There is a blind SQL injection in the lancompenent component, allowing logged-in attackers to discover arbitrary information."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://mbconnectline.com/security-advice/",
"refsource": "CONFIRM",
"url": "https://mbconnectline.com/security-advice/"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2020-24568",
"datePublished": "2020-10-02T18:19:43.000Z",
"dateReserved": "2020-08-21T00:00:00.000Z",
"dateUpdated": "2024-08-04T15:19:09.015Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"epss": {
"cve": "CVE-2020-24568",
"date": "2026-05-26",
"epss": "0.00401",
"percentile": "0.60868"
},
"nvd": "{\"cve\":{\"id\":\"CVE-2020-24568\",\"sourceIdentifier\":\"cve@mitre.org\",\"published\":\"2020-10-02T19:15:13.477\",\"lastModified\":\"2024-11-21T05:15:00.590\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"An issue was discovered in MB CONNECT LINE mymbCONNECT24 and mbCONNECT24 through 2.6.1. There is a blind SQL injection in the lancompenent component, allowing logged-in attackers to discover arbitrary information.\"},{\"lang\":\"es\",\"value\":\"Se detect\u00f3 un problema en MB CONNECT LINE mymbCONNECT24 y mbCONNECT24 versiones hasta 2.6.1.\u0026#xa0;Se presenta una inyecci\u00f3n SQL ciega en el componente lancompenent, lo que permite a atacantes que han iniciado sesi\u00f3n detectar informaci\u00f3n arbitraria\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N\",\"baseScore\":6.5,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"NONE\"},\"exploitabilityScore\":2.8,\"impactScore\":3.6}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:L/Au:S/C:P/I:N/A:N\",\"baseScore\":4.0,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"LOW\",\"authentication\":\"SINGLE\",\"confidentialityImpact\":\"PARTIAL\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"NONE\"},\"baseSeverity\":\"MEDIUM\",\"exploitabilityScore\":8.0,\"impactScore\":2.9,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-89\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:mbconnectline:mbconnect24:*:*:*:*:*:*:*:*\",\"versionEndIncluding\":\"2.6.1\",\"matchCriteriaId\":\"C9AD8797-E4EC-4740-997B-8544E40A69BC\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:mbconnectline:mymbconnect24:*:*:*:*:*:*:*:*\",\"versionEndIncluding\":\"2.6.1\",\"matchCriteriaId\":\"64885B25-1389-40BA-830A-260ADFE66C8A\"}]}]}],\"references\":[{\"url\":\"https://mbconnectline.com/security-advice/\",\"source\":\"cve@mitre.org\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://mbconnectline.com/security-advice/\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Vendor Advisory\"]}]}}"
}
}
FKIE_CVE-2020-24568
Vulnerability from fkie_nvd - Published: 2020-10-02 19:15 - Updated: 2024-11-21 05:15| URL | Tags | ||
|---|---|---|---|
| cve@mitre.org | https://mbconnectline.com/security-advice/ | Vendor Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | https://mbconnectline.com/security-advice/ | Vendor Advisory |
| Vendor | Product | Version | |
|---|---|---|---|
| mbconnectline | mbconnect24 | * | |
| mbconnectline | mymbconnect24 | * |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:mbconnectline:mbconnect24:*:*:*:*:*:*:*:*",
"matchCriteriaId": "C9AD8797-E4EC-4740-997B-8544E40A69BC",
"versionEndIncluding": "2.6.1",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:mbconnectline:mymbconnect24:*:*:*:*:*:*:*:*",
"matchCriteriaId": "64885B25-1389-40BA-830A-260ADFE66C8A",
"versionEndIncluding": "2.6.1",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "An issue was discovered in MB CONNECT LINE mymbCONNECT24 and mbCONNECT24 through 2.6.1. There is a blind SQL injection in the lancompenent component, allowing logged-in attackers to discover arbitrary information."
},
{
"lang": "es",
"value": "Se detect\u00f3 un problema en MB CONNECT LINE mymbCONNECT24 y mbCONNECT24 versiones hasta 2.6.1.\u0026#xa0;Se presenta una inyecci\u00f3n SQL ciega en el componente lancompenent, lo que permite a atacantes que han iniciado sesi\u00f3n detectar informaci\u00f3n arbitraria"
}
],
"id": "CVE-2020-24568",
"lastModified": "2024-11-21T05:15:00.590",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "MEDIUM",
"cvssData": {
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "SINGLE",
"availabilityImpact": "NONE",
"baseScore": 4.0,
"confidentialityImpact": "PARTIAL",
"integrityImpact": "NONE",
"vectorString": "AV:N/AC:L/Au:S/C:P/I:N/A:N",
"version": "2.0"
},
"exploitabilityScore": 8.0,
"impactScore": 2.9,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": false
}
],
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
},
"exploitabilityScore": 2.8,
"impactScore": 3.6,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2020-10-02T19:15:13.477",
"references": [
{
"source": "cve@mitre.org",
"tags": [
"Vendor Advisory"
],
"url": "https://mbconnectline.com/security-advice/"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Vendor Advisory"
],
"url": "https://mbconnectline.com/security-advice/"
}
],
"sourceIdentifier": "cve@mitre.org",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-89"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
GHSA-88FX-FGPH-RP43
Vulnerability from github – Published: 2022-05-24 17:30 – Updated: 2022-05-24 17:30An issue was discovered in MB CONNECT LINE mymbCONNECT24 and mbCONNECT24 through 2.6.1. There is a blind SQL injection in the lancompenent component, allowing logged-in attackers to discover arbitrary information.
{
"affected": [],
"aliases": [
"CVE-2020-24568"
],
"database_specific": {
"cwe_ids": [],
"github_reviewed": false,
"github_reviewed_at": null,
"nvd_published_at": "2020-10-02T19:15:00Z",
"severity": "MODERATE"
},
"details": "An issue was discovered in MB CONNECT LINE mymbCONNECT24 and mbCONNECT24 through 2.6.1. There is a blind SQL injection in the lancompenent component, allowing logged-in attackers to discover arbitrary information.",
"id": "GHSA-88fx-fgph-rp43",
"modified": "2022-05-24T17:30:00Z",
"published": "2022-05-24T17:30:00Z",
"references": [
{
"type": "ADVISORY",
"url": "https://nvd.nist.gov/vuln/detail/CVE-2020-24568"
},
{
"type": "WEB",
"url": "https://mbconnectline.com/security-advice"
}
],
"schema_version": "1.4.0",
"severity": []
}
GSD-2020-24568
Vulnerability from gsd - Updated: 2023-12-13 01:22{
"GSD": {
"alias": "CVE-2020-24568",
"description": "An issue was discovered in MB CONNECT LINE mymbCONNECT24 and mbCONNECT24 through 2.6.1. There is a blind SQL injection in the lancompenent component, allowing logged-in attackers to discover arbitrary information.",
"id": "GSD-2020-24568"
},
"gsd": {
"metadata": {
"exploitCode": "unknown",
"remediation": "unknown",
"reportConfidence": "confirmed",
"type": "vulnerability"
},
"osvSchema": {
"aliases": [
"CVE-2020-24568"
],
"details": "An issue was discovered in MB CONNECT LINE mymbCONNECT24 and mbCONNECT24 through 2.6.1. There is a blind SQL injection in the lancompenent component, allowing logged-in attackers to discover arbitrary information.",
"id": "GSD-2020-24568",
"modified": "2023-12-13T01:22:12.315754Z",
"schema_version": "1.4.0"
}
},
"namespaces": {
"cve.org": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2020-24568",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "An issue was discovered in MB CONNECT LINE mymbCONNECT24 and mbCONNECT24 through 2.6.1. There is a blind SQL injection in the lancompenent component, allowing logged-in attackers to discover arbitrary information."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://mbconnectline.com/security-advice/",
"refsource": "CONFIRM",
"url": "https://mbconnectline.com/security-advice/"
}
]
}
},
"nvd.nist.gov": {
"configurations": {
"CVE_data_version": "4.0",
"nodes": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:a:mbconnectline:mbconnect24:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndIncluding": "2.6.1",
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:mbconnectline:mymbconnect24:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndIncluding": "2.6.1",
"vulnerable": true
}
],
"operator": "OR"
}
]
},
"cve": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2020-24568"
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "en",
"value": "An issue was discovered in MB CONNECT LINE mymbCONNECT24 and mbCONNECT24 through 2.6.1. There is a blind SQL injection in the lancompenent component, allowing logged-in attackers to discover arbitrary information."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "en",
"value": "CWE-89"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://mbconnectline.com/security-advice/",
"refsource": "CONFIRM",
"tags": [
"Vendor Advisory"
],
"url": "https://mbconnectline.com/security-advice/"
}
]
}
},
"impact": {
"baseMetricV2": {
"acInsufInfo": false,
"cvssV2": {
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "SINGLE",
"availabilityImpact": "NONE",
"baseScore": 4.0,
"confidentialityImpact": "PARTIAL",
"integrityImpact": "NONE",
"vectorString": "AV:N/AC:L/Au:S/C:P/I:N/A:N",
"version": "2.0"
},
"exploitabilityScore": 8.0,
"impactScore": 2.9,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"severity": "MEDIUM",
"userInteractionRequired": false
},
"baseMetricV3": {
"cvssV3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
},
"exploitabilityScore": 2.8,
"impactScore": 3.6
}
},
"lastModifiedDate": "2020-10-15T12:04Z",
"publishedDate": "2020-10-02T19:15Z"
}
}
}
ICSA-20-273-01
Vulnerability from csaf_cisa - Published: 2020-09-29 00:00 - Updated: 2020-09-29 00:00{
"document": {
"acknowledgments": [
{
"names": [
"Alik Koldobsky",
"Ofir Manzur",
"Hay Mizrachi",
"Nikolay Sokolik",
"Haviv Vaizman"
],
"organization": "OTORIO",
"summary": "reporting these vulnerabilities to CISA"
}
],
"category": "csaf_security_advisory",
"csaf_version": "2.0",
"distribution": {
"text": "Disclosure is not limited",
"tlp": {
"label": "WHITE"
}
},
"lang": "en-US",
"notes": [
{
"category": "general",
"text": "This CSAF advisory was extracted from unstructured data and may contain inaccuracies. If you notice any errors, please reach out to the designated contact at CISA CSAF: central@cisa.dhs.gov",
"title": "CISA Disclaimer"
},
{
"category": "summary",
"text": "Alik Koldobsky, Ofir Manzur, Hay Mizrachi, Nikolay Sokolik, and Haviv Vaizman from OTORIO reported these vulnerabilities to CISA.",
"title": "Summary"
},
{
"category": "other",
"text": "No known public exploits specifically target these vulnerabilities.",
"title": "Exploitability"
}
],
"publisher": {
"category": "coordinator",
"contact_details": "CISAservicedesk@cisa.dhs.gov",
"name": "CISA",
"namespace": "https://www.cisa.gov/"
},
"references": [
{
"category": "self",
"summary": "ICS Advisory ICSA-20-273-01 JSON",
"url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2020/icsa-20-273-01.json"
},
{
"category": "self",
"summary": "ICS Advisory ICSA-20-273-01 Web Version",
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-20-273-01"
}
],
"title": "ICSA-20-273-01_MB Connect line mbCONNECT24, mymbCONNECT24",
"tracking": {
"current_release_date": "2020-09-29T00:00:00.000000Z",
"generator": {
"engine": {
"name": "CISA USCert CSAF Generator",
"version": "1"
}
},
"id": "ICSA-20-273-01",
"initial_release_date": "2020-09-29T00:00:00.000000Z",
"revision_history": [
{
"date": "2020-09-29T00:00:00.000000Z",
"legacy_version": "Initial",
"number": "1",
"summary": "ICSA-20-273-01 MB Connect line mbCONNECT24, mymbCONNECT24"
}
],
"status": "final",
"version": "1"
}
},
"product_tree": {
"branches": [
{
"branches": [
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c= 2.6.1",
"product": {
"name": "mbCONNECT24: v2.6.1 and prior",
"product_id": "CSAFPID-0001"
}
}
],
"category": "product_name",
"name": "mbCONNECT24"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c= 2.6.1",
"product": {
"name": "mymbCONNECT24: v2.6.1 and prior",
"product_id": "CSAFPID-0002"
}
}
],
"category": "product_name",
"name": "mymbCONNECT24"
}
],
"category": "vendor",
"name": "MB connect line"
}
]
},
"vulnerabilities": [
{
"cve": "CVE-2020-24569",
"cwe": {
"id": "CWE-77",
"name": "Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)"
},
"notes": [
{
"category": "summary",
"text": "There is a blind SQL injection vulnerability in the knximport component that allows logged in attackers access to arbitrary information. CVE-2020-24569 has been assigned to this vulnerability. A CVSS v3 base score of 7.1 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:L).",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
"references": [
{
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:L"
}
],
"remediations": [
{
"category": "vendor_fix",
"details": "MB connect line recommends users update mymbCONNECT24 and mbCONNECT24 to Version 2.6.2 or higher.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
{
"category": "mitigation",
"details": "Additional details can be found on the MB connect line website.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
],
"url": "https://mbconnectline.com/security-advice/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.1,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:L",
"version": "3.0"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002"
]
}
],
"title": "CVE-2020-24569"
},
{
"cve": "CVE-2020-24568",
"cwe": {
"id": "CWE-77",
"name": "Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)"
},
"notes": [
{
"category": "summary",
"text": "There is a blind SQL injection vulnerability in the lancompenent component that allows logged in attackers to access arbitrary information. CVE-2020-24568 has been assigned to this vulnerability. A CVSS v3 base score of 7.1 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:L).",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
"references": [
{
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:L"
}
],
"remediations": [
{
"category": "vendor_fix",
"details": "MB connect line recommends users update mymbCONNECT24 and mbCONNECT24 to Version 2.6.2 or higher.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
{
"category": "mitigation",
"details": "Additional details can be found on the MB connect line website.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
],
"url": "https://mbconnectline.com/security-advice/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.1,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:L",
"version": "3.0"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002"
]
}
],
"title": "CVE-2020-24568"
},
{
"cve": "CVE-2020-24570",
"cwe": {
"id": "CWE-77",
"name": "Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)"
},
"notes": [
{
"category": "summary",
"text": "There is a SSRF and CSRF vulnerability in the com_mb24proxy module that allows an attacker to steal session information from logged in users with a specifically crafted link. CVE-2020-24570 has been assigned to this vulnerability. A CVSS v3 base score of 8.8 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H).",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
"references": [
{
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H"
}
],
"remediations": [
{
"category": "vendor_fix",
"details": "MB connect line recommends users update mymbCONNECT24 and mbCONNECT24 to Version 2.6.2 or higher.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
{
"category": "mitigation",
"details": "Additional details can be found on the MB connect line website.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
],
"url": "https://mbconnectline.com/security-advice/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.0"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002"
]
}
],
"title": "CVE-2020-24570"
}
]
}
VDE-2020-035
Vulnerability from csaf_mbconnectlinegmbh - Published: 2020-09-18 12:30 - Updated: 2025-05-14 12:28An issue was discovered in MB CONNECT LINE mymbCONNECT24 and mbCONNECT24 through 2.6.1. There is a blind SQL injection in the lancompenent component, allowing logged-in attackers to discover arbitrary information.
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
Software mbCONNECT24 >v2.6.1
MB connect line / Software / mbCONNECT24
|
>v2.6.1 | ||
|
Software mymbCONNECT24 >v2.6.1
MB connect line / Software / mymbCONNECT24
|
>v2.6.1 |
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
Software mbCONNECT24 <=2.6.1
MB connect line / Software / mbCONNECT24
|
<=2.6.1 | ||
|
Software mymbCONNECT24 <=2.6.1
MB connect line / Software / mymbCONNECT24
|
<=2.6.1 |
An issue was discovered in the mymbCONNECT24 and mbCONNECT24 software in all versions through V2.6.1. There is a SSRF and CSRF issue, in the com_mb24proxy module, allowing attackers to steal session information from logged in users with a specifically crafted link.
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
Software mbCONNECT24 >v2.6.1
MB connect line / Software / mbCONNECT24
|
>v2.6.1 | ||
|
Software mymbCONNECT24 >v2.6.1
MB connect line / Software / mymbCONNECT24
|
>v2.6.1 |
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
Software mbCONNECT24 <=2.6.1
MB connect line / Software / mbCONNECT24
|
<=2.6.1 | ||
|
Software mymbCONNECT24 <=2.6.1
MB connect line / Software / mymbCONNECT24
|
<=2.6.1 |
An issue was discovered in MB CONNECT LINE mymbCONNECT24 and mbCONNECT24 through 2.6.1. There is a blind SQL injection in the knximport component via an advanced attack vector, allowing logged in attackers to discover arbitrary information.
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
Software mbCONNECT24 >v2.6.1
MB connect line / Software / mbCONNECT24
|
>v2.6.1 | ||
|
Software mymbCONNECT24 >v2.6.1
MB connect line / Software / mymbCONNECT24
|
>v2.6.1 |
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
Software mbCONNECT24 <=2.6.1
MB connect line / Software / mbCONNECT24
|
<=2.6.1 | ||
|
Software mymbCONNECT24 <=2.6.1
MB connect line / Software / mymbCONNECT24
|
<=2.6.1 |
{
"document": {
"acknowledgments": [
{
"names": [
"Sharon Brizinov",
"Tal Keren"
],
"organization": "OTORIO ",
"summary": "reported"
},
{
"organization": "CERT@VDE",
"summary": "coordination"
}
],
"category": "csaf_security_advisory",
"csaf_version": "2.0",
"distribution": {
"tlp": {
"label": "WHITE",
"url": "https://www.first.org/tlp/"
}
},
"lang": "en-GB",
"notes": [
{
"category": "summary",
"text": "Multiples issues exist in mymbCONNECT24 and mbCONNECT24",
"title": "Summary"
},
{
"category": "description",
"text": "Please consult the above CVEs for details.",
"title": "Impact"
},
{
"category": "description",
"text": "Update mymbCONNECT24 and mbCONNECT24 to version \u003ev2.6.1",
"title": "Remediation"
}
],
"publisher": {
"category": "vendor",
"contact_details": "security-team@mbconnectline.de",
"name": "MB connect line GmbH",
"namespace": "https://mbconnectline.com"
},
"references": [
{
"category": "external",
"summary": "CERT@VDE Security Advisories for MB connect line GmbH",
"url": "https://certvde.com/de/advisories/vendor/mbconnectline/"
},
{
"category": "self",
"summary": "VDE-2020-035: MB connect line: Multiple Vulnerabilities in mymbCONNECT24 and mbCONNECT24 \u003c= v2.6.1 - HTML",
"url": "https://certvde.com/de/advisories/VDE-2020-035/"
},
{
"category": "self",
"summary": "VDE-2020-035: MB connect line: Multiple Vulnerabilities in mymbCONNECT24 and mbCONNECT24 \u003c= v2.6.1 - CSAF",
"url": "https://mbconnectline.csaf-tp.certvde.com/.well-known/csaf/white/2020/vde-2020-035.json"
}
],
"title": "MB connect line: Multiple Vulnerabilities in mymbCONNECT24 and mbCONNECT24 \u003c= v2.6.1",
"tracking": {
"aliases": [
"VDE-2020-035"
],
"current_release_date": "2025-05-14T12:28:19.000Z",
"generator": {
"date": "2024-09-30T11:26:22.467Z",
"engine": {
"name": "Secvisogram",
"version": "2.5.12"
}
},
"id": "VDE-2020-035",
"initial_release_date": "2020-09-18T12:30:00.000Z",
"revision_history": [
{
"date": "2020-09-18T12:30:00.000Z",
"number": "1",
"summary": "Initial revision."
},
{
"date": "2024-11-06T11:27:01.000Z",
"number": "2",
"summary": "Fix: added self-reference"
},
{
"date": "2025-02-12T16:48:47.000Z",
"number": "3",
"summary": "Fix: corrected self-reference, fixed version"
},
{
"date": "2025-05-14T12:28:19.000Z",
"number": "4",
"summary": "Fix: removed ia, added distribution"
}
],
"status": "final",
"version": "4"
}
},
"product_tree": {
"branches": [
{
"branches": [
{
"branches": [
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c=2.6.1",
"product": {
"name": "Software mbCONNECT24 \u003c=2.6.1",
"product_id": "CSAFPID-51001"
}
},
{
"category": "product_version_range",
"name": "\u003ev2.6.1",
"product": {
"name": "Software mbCONNECT24 \u003ev2.6.1",
"product_id": "CSAFPID-52001"
}
}
],
"category": "product_name",
"name": "mbCONNECT24"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c=2.6.1",
"product": {
"name": "Software mymbCONNECT24 \u003c=2.6.1",
"product_id": "CSAFPID-51002"
}
},
{
"category": "product_version_range",
"name": "\u003ev2.6.1",
"product": {
"name": "Software mymbCONNECT24 \u003ev2.6.1",
"product_id": "CSAFPID-52002"
}
}
],
"category": "product_name",
"name": "mymbCONNECT24"
}
],
"category": "product_family",
"name": "Software"
}
],
"category": "vendor",
"name": "MB connect line"
}
],
"product_groups": [
{
"group_id": "CSAFGID-0001",
"product_ids": [
"CSAFPID-51001",
"CSAFPID-51002"
],
"summary": "Affected products."
},
{
"group_id": "CSAFGID-0002",
"product_ids": [
"CSAFPID-52001",
"CSAFPID-52002"
],
"summary": "Fixed products."
}
]
},
"vulnerabilities": [
{
"cve": "CVE-2020-24568",
"cwe": {
"id": "CWE-89",
"name": "Improper Neutralization of Special Elements used in an SQL Command (\u0027SQL Injection\u0027)"
},
"notes": [
{
"audience": "all",
"category": "description",
"text": "An issue was discovered in MB CONNECT LINE mymbCONNECT24 and mbCONNECT24 through 2.6.1. There is a blind SQL injection in the lancompenent component, allowing logged-in attackers to discover arbitrary information.",
"title": "Vulnerability Description"
}
],
"product_status": {
"fixed": [
"CSAFPID-52001",
"CSAFPID-52002"
],
"known_affected": [
"CSAFPID-51001",
"CSAFPID-51002"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update mymbCONNECT24 and mbCONNECT24 to version \u003ev2.6.1",
"group_ids": [
"CSAFGID-0001"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"environmentalScore": 6.5,
"environmentalSeverity": "MEDIUM",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"temporalScore": 6.5,
"temporalSeverity": "MEDIUM",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
},
"products": [
"CSAFPID-51001",
"CSAFPID-51002"
]
}
],
"title": "CVE-2020-24568"
},
{
"cve": "CVE-2020-24570",
"cwe": {
"id": "CWE-352",
"name": "Cross-Site Request Forgery (CSRF)"
},
"notes": [
{
"audience": "all",
"category": "description",
"text": "An issue was discovered in the mymbCONNECT24 and mbCONNECT24 software in all versions through V2.6.1. There is a SSRF and CSRF issue, in the com_mb24proxy module, allowing attackers to steal session information from logged in users with a specifically crafted link.",
"title": "Vulnerability Description"
}
],
"product_status": {
"fixed": [
"CSAFPID-52001",
"CSAFPID-52002"
],
"known_affected": [
"CSAFPID-51001",
"CSAFPID-51002"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update mymbCONNECT24 and mbCONNECT24 to version \u003ev2.6.1",
"group_ids": [
"CSAFGID-0001"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"environmentalScore": 6.5,
"environmentalSeverity": "MEDIUM",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"temporalScore": 6.5,
"temporalSeverity": "MEDIUM",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:N",
"version": "3.1"
},
"products": [
"CSAFPID-51001",
"CSAFPID-51002"
]
}
],
"title": "CVE-2020-24570"
},
{
"cve": "CVE-2020-24569",
"cwe": {
"id": "CWE-89",
"name": "Improper Neutralization of Special Elements used in an SQL Command (\u0027SQL Injection\u0027)"
},
"notes": [
{
"category": "description",
"text": "An issue was discovered in MB CONNECT LINE mymbCONNECT24 and mbCONNECT24 through 2.6.1. There is a blind SQL injection in the knximport component via an advanced attack vector, allowing logged in attackers to discover arbitrary information.",
"title": "Vulnerability Description"
}
],
"product_status": {
"fixed": [
"CSAFPID-52001",
"CSAFPID-52002"
],
"known_affected": [
"CSAFPID-51001",
"CSAFPID-51002"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update mymbCONNECT24 and mbCONNECT24 to version \u003ev2.6.1",
"group_ids": [
"CSAFGID-0001"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 4.3,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"environmentalScore": 4.3,
"environmentalSeverity": "MEDIUM",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"temporalScore": 4.3,
"temporalSeverity": "MEDIUM",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N",
"version": "3.1"
},
"products": [
"CSAFPID-51001",
"CSAFPID-51002"
]
}
],
"title": "CVE-2020-24569"
}
]
}
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.