CVE-2020-12001 (GCVE-0-2020-12001)

Vulnerability from cvelistv5 – Published: 2020-06-15 19:14 – Updated: 2024-08-04 11:48
VLAI
Summary
FactoryTalk Linx versions 6.00, 6.10, and 6.11, RSLinx Classic v4.11.00 and prior,Connected Components Workbench: Version 12 and prior, ControlFLASH: Version 14 and later, ControlFLASH Plus: Version 1 and later, FactoryTalk Asset Centre: Version 9 and later, FactoryTalk Linx CommDTM: Version 1 and later, Studio 5000 Launcher: Version 31 and later Stud, 5000 Logix Designer software: Version 32 and prior is vulnerable. The parsing mechanism that processes certain file types does not provide input sanitation. This may allow an attacker to use specially crafted files to traverse the file system and modify or expose sensitive data or execute arbitrary code.
CWE
  • CWE-20 - IMPROPER INPUT VALIDATION CWE-20
Assigner
icscert CNA under the icscert root
CNA scorecard B 75/100 over 336 records in the last 180 days details
References
Impacted products
Vendor Product Version CPE status
n/a FactoryTalk Linx, RSLinx Classic, Connected Components Workbench, ControlFLASH Plus, FactoryTalk Asset Centre, FactoryTalk Linx CommDTM, Studio 5000 Launcher, Studio 5000 Logix Designer software Affected: FactoryTalk Linx versions 6.00, 6.10, and 6.11, RSLinx Classic v4.11.00 and prior,Connected Components Workbench: Version 12 and prior, ControlFLASH: Version 14 and later, ControlFLASH Plus: Version 1 and later, FactoryTalk Asset Centre: Version 9 and later, FactoryTalk Linx CommDTM: Version 1 and later, Studio 5000 Launcher: Version 31 and later Stud, 5000 Logix Designer software: Version 32 and prior
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T11:48:57.384Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.us-cert.gov/ics/advisories/icsa-20-163-02"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.zerodayinitiative.com/advisories/ZDI-20-733/"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "FactoryTalk Linx, RSLinx Classic, Connected Components Workbench, ControlFLASH Plus, FactoryTalk Asset Centre, FactoryTalk Linx CommDTM, Studio 5000 Launcher, Studio 5000 Logix Designer software",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "FactoryTalk Linx versions 6.00, 6.10, and 6.11, RSLinx Classic v4.11.00 and prior,Connected Components Workbench: Version 12 and prior, ControlFLASH: Version 14 and later, ControlFLASH Plus: Version 1 and later, FactoryTalk Asset Centre: Version 9 and later, FactoryTalk Linx CommDTM: Version 1 and later, Studio 5000 Launcher: Version 31 and later Stud, 5000 Logix Designer software: Version 32 and prior"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "FactoryTalk Linx versions 6.00, 6.10, and 6.11, RSLinx Classic v4.11.00 and prior,Connected Components Workbench: Version 12 and prior, ControlFLASH: Version 14 and later, ControlFLASH Plus: Version 1 and later, FactoryTalk Asset Centre: Version 9 and later, FactoryTalk Linx CommDTM: Version 1 and later, Studio 5000 Launcher: Version 31 and later Stud, 5000 Logix Designer software: Version 32 and prior is vulnerable. The parsing mechanism that processes certain file types does not provide input sanitation. This may allow an attacker to use specially crafted files to traverse the file system and modify or expose sensitive data or execute arbitrary code."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-20",
              "description": "IMPROPER INPUT VALIDATION CWE-20",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2020-06-22T23:06:17.000Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.us-cert.gov/ics/advisories/icsa-20-163-02"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.zerodayinitiative.com/advisories/ZDI-20-733/"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "ID": "CVE-2020-12001",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "FactoryTalk Linx, RSLinx Classic, Connected Components Workbench, ControlFLASH Plus, FactoryTalk Asset Centre, FactoryTalk Linx CommDTM, Studio 5000 Launcher, Studio 5000 Logix Designer software",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "FactoryTalk Linx versions 6.00, 6.10, and 6.11, RSLinx Classic v4.11.00 and prior,Connected Components Workbench: Version 12 and prior, ControlFLASH: Version 14 and later, ControlFLASH Plus: Version 1 and later, FactoryTalk Asset Centre: Version 9 and later, FactoryTalk Linx CommDTM: Version 1 and later, Studio 5000 Launcher: Version 31 and later Stud, 5000 Logix Designer software: Version 32 and prior"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "FactoryTalk Linx versions 6.00, 6.10, and 6.11, RSLinx Classic v4.11.00 and prior,Connected Components Workbench: Version 12 and prior, ControlFLASH: Version 14 and later, ControlFLASH Plus: Version 1 and later, FactoryTalk Asset Centre: Version 9 and later, FactoryTalk Linx CommDTM: Version 1 and later, Studio 5000 Launcher: Version 31 and later Stud, 5000 Logix Designer software: Version 32 and prior is vulnerable. The parsing mechanism that processes certain file types does not provide input sanitation. This may allow an attacker to use specially crafted files to traverse the file system and modify or expose sensitive data or execute arbitrary code."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "IMPROPER INPUT VALIDATION CWE-20"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.us-cert.gov/ics/advisories/icsa-20-163-02",
              "refsource": "MISC",
              "url": "https://www.us-cert.gov/ics/advisories/icsa-20-163-02"
            },
            {
              "name": "https://www.zerodayinitiative.com/advisories/ZDI-20-733/",
              "refsource": "MISC",
              "url": "https://www.zerodayinitiative.com/advisories/ZDI-20-733/"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2020-12001",
    "datePublished": "2020-06-15T19:14:18.000Z",
    "dateReserved": "2020-04-21T00:00:00.000Z",
    "dateUpdated": "2024-08-04T11:48:57.384Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "epss": {
      "cve": "CVE-2020-12001",
      "date": "2026-11-26",
      "epss": "0.11783",
      "percentile": "0.96781"
    },
    "nvd": {
      "cve": {
        "configurations": [
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:a:rockwellautomation:factorytalk_linx:6.00:*:*:*:*:*:*:*",
                    "matchCriteriaId": "244B67F2-DEC2-44E2-94F1-F6A82249453C",
                    "vulnerable": true
                  },
                  {
                    "criteria": "cpe:2.3:a:rockwellautomation:factorytalk_linx:6.10:*:*:*:*:*:*:*",
                    "matchCriteriaId": "767F223A-C4CE-49DE-B66F-51345E91C98F",
                    "vulnerable": true
                  },
                  {
                    "criteria": "cpe:2.3:a:rockwellautomation:factorytalk_linx:6.11:*:*:*:*:*:*:*",
                    "matchCriteriaId": "5675EA61-1854-4AA1-BA1B-E07442E1F10C",
                    "vulnerable": true
                  },
                  {
                    "criteria": "cpe:2.3:a:rockwellautomation:rslinx_classic:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "4F6780E2-AB8D-4860-812F-CBE82A94EF0D",
                    "versionEndIncluding": "4.11.00",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ]
          }
        ],
        "cveTags": [],
        "descriptions": [
          {
            "lang": "en",
            "value": "FactoryTalk Linx versions 6.00, 6.10, and 6.11, RSLinx Classic v4.11.00 and prior,Connected Components Workbench: Version 12 and prior, ControlFLASH: Version 14 and later, ControlFLASH Plus: Version 1 and later, FactoryTalk Asset Centre: Version 9 and later, FactoryTalk Linx CommDTM: Version 1 and later, Studio 5000 Launcher: Version 31 and later Stud, 5000 Logix Designer software: Version 32 and prior is vulnerable. The parsing mechanism that processes certain file types does not provide input sanitation. This may allow an attacker to use specially crafted files to traverse the file system and modify or expose sensitive data or execute arbitrary code."
          },
          {
            "lang": "es",
            "value": "FactoryTalk Linx versiones 6.00, 6.10 y 6.11, RSLinx Classic versiones v4.11.00 y anteriores, Connected Components Workbench: versi\u00f3n 12 y anteriores, ControlFLASH: versi\u00f3n 14 y posteriores, ControlFLASH Plus: versi\u00f3n 1 y posteriores, FactoryTalk Asset Center: versi\u00f3n 9 y posteriores , FactoryTalk Linx CommDTM: versi\u00f3n 1 y posteriores, Studio 5000 Launcher: versi\u00f3n 31 y posteriores a Stud, software 5000 Logix Designer: versi\u00f3n 32 y anteriores son vulnerables. El mecanismo de an\u00e1lisis que procesa determinados tipos de archivos no proporciona un saneamiento de entrada. Esto puede permitir a un atacante usar archivos especialmente dise\u00f1ados para atravesar el sistema de archivos y modificar o exponer datos confidenciales o ejecutar c\u00f3digo arbitrario"
          }
        ],
        "id": "CVE-2020-12001",
        "lastModified": "2024-11-21T04:59:05.470",
        "metrics": {
          "cvssMetricV2": [
            {
              "acInsufInfo": false,
              "baseSeverity": "HIGH",
              "cvssData": {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "availabilityImpact": "PARTIAL",
                "baseScore": 7.5,
                "confidentialityImpact": "PARTIAL",
                "integrityImpact": "PARTIAL",
                "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
                "version": "2.0"
              },
              "exploitabilityScore": 10.0,
              "impactScore": 6.4,
              "obtainAllPrivilege": false,
              "obtainOtherPrivilege": false,
              "obtainUserPrivilege": false,
              "source": "nvd@nist.gov",
              "type": "Primary",
              "userInteractionRequired": false
            }
          ],
          "cvssMetricV31": [
            {
              "cvssData": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 9.8,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "exploitabilityScore": 3.9,
              "impactScore": 5.9,
              "source": "nvd@nist.gov",
              "type": "Primary"
            }
          ]
        },
        "published": "2020-06-15T20:15:11.317",
        "references": [
          {
            "source": "ics-cert@hq.dhs.gov",
            "tags": [
              "Third Party Advisory",
              "US Government Resource"
            ],
            "url": "https://www.us-cert.gov/ics/advisories/icsa-20-163-02"
          },
          {
            "source": "ics-cert@hq.dhs.gov",
            "tags": [
              "Third Party Advisory",
              "VDB Entry"
            ],
            "url": "https://www.zerodayinitiative.com/advisories/ZDI-20-733/"
          },
          {
            "source": "af854a3a-2127-422b-91ae-364da2661108",
            "tags": [
              "Third Party Advisory",
              "US Government Resource"
            ],
            "url": "https://www.us-cert.gov/ics/advisories/icsa-20-163-02"
          },
          {
            "source": "af854a3a-2127-422b-91ae-364da2661108",
            "tags": [
              "Third Party Advisory",
              "VDB Entry"
            ],
            "url": "https://www.zerodayinitiative.com/advisories/ZDI-20-733/"
          }
        ],
        "sourceIdentifier": "ics-cert@hq.dhs.gov",
        "vulnStatus": "Modified",
        "weaknesses": [
          {
            "description": [
              {
                "lang": "en",
                "value": "CWE-20"
              }
            ],
            "source": "ics-cert@hq.dhs.gov",
            "type": "Secondary"
          },
          {
            "description": [
              {
                "lang": "en",
                "value": "CWE-20"
              }
            ],
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ]
      }
    }
  }
}



Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Drag nodes to arrange them. Double-click a related vulnerability to open it, or a source to visit its link. The Physics button on the left tunes the layout and the simulation; the legend at the bottom left hides or shows nodes by kind and by sighting type.

Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Vulnerability timeline

Sightings and recorded dates, grouped by day · UTC

JSON
How durations are calculated

Following the VTEM framework (Black Hat USA 2015), time to patch starts when the vendor or a coordinator was informed, total time to patch at discovery, and disclosure to patch at public disclosure; vendor response time runs from the report to its acknowledgement. Time to exploit and time unpatched start at the earliest discovery or report, falling back to public disclosure. Unpatched time ends at the first recorded patch, or the calculation time when no patch is recorded. Exploitation to patch shows the interval between those two events; a published proof of concept is a public exploit, not exploitation. The method is described in a publication.

Each result shows its source dates. A negative interval means the end event came first; when date-only inputs leave the order open, the result says so. Date-only inputs are approximate. The earliest evidence wins: KEV report dates and sightings are labelled as such. Records describing another vulnerability are listed but never calculated from, and a PoC alone does not establish exploitation. Missing patch evidence does not prove that no patch exists. Filters below change the event list only.

Events included in the timeline

Loading timeline…


    Loading…

    Loading…

    Loading…

    Related by attack behaviour

    Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.