CVE-2019-6585 (GCVE-0-2019-6585)
Vulnerability from cvelistv5 – Published: 2020-03-10 19:16 – Updated: 2024-08-04 20:23
VLAI?
Summary
A vulnerability has been identified in SCALANCE S602 (All versions >= V3.0 and < V4.1), SCALANCE S612 (All versions >= V3.0 and < V4.1), SCALANCE S623 (All versions >= V3.0 and < V4.1), SCALANCE S627-2M (All versions >= V3.0 and < V4.1). The integrated configuration web server of the affected devices could allow Cross-Site Scripting (XSS) attacks if unsuspecting users are tricked into accessing a malicious link. User interaction is required for a successful exploitation. The user must be logged into the web interface in order for the exploitation to succeed.
Severity ?
No CVSS data available.
CWE
- CWE-80 - Improper Neutralization of Script-Related HTML Tags in a Web Page (Basic XSS)
Assigner
References
| URL | Tags | |||||||
|---|---|---|---|---|---|---|---|---|
|
||||||||
Impacted products
| Vendor | Product | Version | |||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Siemens | SCALANCE S602 |
Affected:
All versions >= V3.0 and < V4.1
|
|||||||||||||||||
|
|||||||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T20:23:22.461Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-591405.pdf"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.us-cert.gov/ics/advisories/icsa-20-042-10"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "SCALANCE S602",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003e= V3.0 and \u003c V4.1"
}
]
},
{
"product": "SCALANCE S612",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003e= V3.0 and \u003c V4.1"
}
]
},
{
"product": "SCALANCE S623",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003e= V3.0 and \u003c V4.1"
}
]
},
{
"product": "SCALANCE S627-2M",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003e= V3.0 and \u003c V4.1"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in SCALANCE S602 (All versions \u003e= V3.0 and \u003c V4.1), SCALANCE S612 (All versions \u003e= V3.0 and \u003c V4.1), SCALANCE S623 (All versions \u003e= V3.0 and \u003c V4.1), SCALANCE S627-2M (All versions \u003e= V3.0 and \u003c V4.1). The integrated configuration web server of the affected devices could allow Cross-Site Scripting (XSS) attacks if unsuspecting users are tricked into accessing a malicious link. User interaction is required for a successful exploitation. The user must be logged into the web interface in order for the exploitation to succeed."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-80",
"description": "CWE-80: Improper Neutralization of Script-Related HTML Tags in a Web Page (Basic XSS)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-04-22T20:42:19",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-591405.pdf"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.us-cert.gov/ics/advisories/icsa-20-042-10"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "productcert@siemens.com",
"ID": "CVE-2019-6585",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "SCALANCE S602",
"version": {
"version_data": [
{
"version_value": "All versions \u003e= V3.0 and \u003c V4.1"
}
]
}
},
{
"product_name": "SCALANCE S612",
"version": {
"version_data": [
{
"version_value": "All versions \u003e= V3.0 and \u003c V4.1"
}
]
}
},
{
"product_name": "SCALANCE S623",
"version": {
"version_data": [
{
"version_value": "All versions \u003e= V3.0 and \u003c V4.1"
}
]
}
},
{
"product_name": "SCALANCE S627-2M",
"version": {
"version_data": [
{
"version_value": "All versions \u003e= V3.0 and \u003c V4.1"
}
]
}
}
]
},
"vendor_name": "Siemens"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A vulnerability has been identified in SCALANCE S602 (All versions \u003e= V3.0 and \u003c V4.1), SCALANCE S612 (All versions \u003e= V3.0 and \u003c V4.1), SCALANCE S623 (All versions \u003e= V3.0 and \u003c V4.1), SCALANCE S627-2M (All versions \u003e= V3.0 and \u003c V4.1). The integrated configuration web server of the affected devices could allow Cross-Site Scripting (XSS) attacks if unsuspecting users are tricked into accessing a malicious link. User interaction is required for a successful exploitation. The user must be logged into the web interface in order for the exploitation to succeed."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-80: Improper Neutralization of Script-Related HTML Tags in a Web Page (Basic XSS)"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-591405.pdf",
"refsource": "CONFIRM",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-591405.pdf"
},
{
"name": "https://www.us-cert.gov/ics/advisories/icsa-20-042-10",
"refsource": "MISC",
"url": "https://www.us-cert.gov/ics/advisories/icsa-20-042-10"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2019-6585",
"datePublished": "2020-03-10T19:16:17",
"dateReserved": "2019-01-22T00:00:00",
"dateUpdated": "2024-08-04T20:23:22.461Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"nvd": "{\"cve\":{\"id\":\"CVE-2019-6585\",\"sourceIdentifier\":\"productcert@siemens.com\",\"published\":\"2020-03-10T20:15:20.257\",\"lastModified\":\"2024-11-21T04:46:45.233\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"A vulnerability has been identified in SCALANCE S602 (All versions \u003e= V3.0 and \u003c V4.1), SCALANCE S612 (All versions \u003e= V3.0 and \u003c V4.1), SCALANCE S623 (All versions \u003e= V3.0 and \u003c V4.1), SCALANCE S627-2M (All versions \u003e= V3.0 and \u003c V4.1). The integrated configuration web server of the affected devices could allow Cross-Site Scripting (XSS) attacks if unsuspecting users are tricked into accessing a malicious link. User interaction is required for a successful exploitation. The user must be logged into the web interface in order for the exploitation to succeed.\"},{\"lang\":\"es\",\"value\":\"Se ha identificado una vulnerabilidad en SCALANCE S602 (Todas las versiones posteriores o iguales a V3.0 y anteriores a V4.1), SCALANCE S612 (Todas las versiones posteriores o iguales a V3.0 y anteriores a V4.1), SCALANCE S623 (Todas las versiones posteriores o iguales a V3.0 y anteriores a V4.1), SCALANCE S627-2M (Todas las versiones posteriores o iguales a V3.0 y anteriores a V4.1). El servidor web de configuraci\u00f3n integrado de los dispositivos afectados podr\u00eda permitir ataques de Cross-Site Scripting (XSS) si los usuarios desprevenidos son enga\u00f1ados para acceder a un enlace malicioso. Se requiere la interacci\u00f3n del usuario para una explotaci\u00f3n exitosa. El usuario debe estar conectado a la interfaz web para que la explotaci\u00f3n tenga \u00e9xito\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N\",\"baseScore\":6.1,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"REQUIRED\",\"scope\":\"CHANGED\",\"confidentialityImpact\":\"LOW\",\"integrityImpact\":\"LOW\",\"availabilityImpact\":\"NONE\"},\"exploitabilityScore\":2.8,\"impactScore\":2.7}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:M/Au:N/C:N/I:P/A:N\",\"baseScore\":4.3,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"MEDIUM\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"PARTIAL\",\"availabilityImpact\":\"NONE\"},\"baseSeverity\":\"MEDIUM\",\"exploitabilityScore\":8.6,\"impactScore\":2.9,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":true}]},\"weaknesses\":[{\"source\":\"productcert@siemens.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-80\"}]},{\"source\":\"nvd@nist.gov\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-79\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:scalance_s602_firmware:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"3.0\",\"versionEndExcluding\":\"4.1\",\"matchCriteriaId\":\"253D14CB-CD7E-40B0-8F3F-1D35FDC46658\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:scalance_s602:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"F4D89D82-C2CE-44DC-A05B-B956F20BF4E3\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:scalance_s612_firmware:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"3.0\",\"versionEndExcluding\":\"4.1\",\"matchCriteriaId\":\"340031C6-BD77-4601-AA35-4B3A85729576\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:scalance_s612:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"CA7B48D2-0D17-420D-AAE1-35E5C0BE2924\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:scalance_s623_firmware:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"3.0\",\"versionEndExcluding\":\"4.1\",\"matchCriteriaId\":\"0E518E7C-EDF2-4E6A-8C9F-7623FC66CC3F\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:scalance_s623:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"F80D9A79-7984-462B-B4B9-6A4429422038\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:scalance_s627-2m_firmware:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"3.0\",\"versionEndExcluding\":\"4.1\",\"matchCriteriaId\":\"5FA5FF74-3117-48F0-8AE6-658B180B7FF0\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:scalance_s627-2m:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"B51B40F8-71D2-4D2D-8EC2-CE154A6D7533\"}]}]}],\"references\":[{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-591405.pdf\",\"source\":\"productcert@siemens.com\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://www.us-cert.gov/ics/advisories/icsa-20-042-10\",\"source\":\"productcert@siemens.com\",\"tags\":[\"Third Party Advisory\",\"US Government Resource\"]},{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-591405.pdf\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://www.us-cert.gov/ics/advisories/icsa-20-042-10\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Third Party Advisory\",\"US Government Resource\"]}]}}"
}
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…