CVE-2019-5433 (GCVE-0-2019-5433)

Vulnerability from cvelistv5 – Published: 2019-05-06 16:51 – Updated: 2024-08-04 19:54
VLAI
Summary
A user having access to the UI of a Revive Adserver instance could be tricked into clicking on a specifically crafted admin account-switch.php URL that would eventually lead them to another (unsafe) domain, potentially used for stealing credentials or other phishing attacks. This vulnerability was addressed in version 4.2.0.
CWE
  • CWE-601 - Open Redirect (CWE-601)
Assigner
hackerone CNA under the mitre root
CNA scorecard D 59/100 over 213 records in the last 180 days details
References
Impacted products
Vendor Product Version CPE status
n/a Revive Adserver Affected: Fixed version v4.2.0
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T19:54:53.436Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.revive-adserver.com/security/revive-sa-2019-001/"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://hackerone.com/reports/390663"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Revive Adserver",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "Fixed version v4.2.0"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A user having access to the UI of a Revive Adserver instance could be tricked into clicking on a specifically crafted admin account-switch.php URL that would eventually lead them to another (unsafe) domain, potentially used for stealing credentials or other phishing attacks. This vulnerability was addressed in version 4.2.0."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-601",
              "description": "Open Redirect (CWE-601)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2019-05-06T16:51:54.000Z",
        "orgId": "36234546-b8fa-4601-9d6f-f4e334aa8ea1",
        "shortName": "hackerone"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.revive-adserver.com/security/revive-sa-2019-001/"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://hackerone.com/reports/390663"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "support@hackerone.com",
          "ID": "CVE-2019-5433",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Revive Adserver",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "Fixed version v4.2.0"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A user having access to the UI of a Revive Adserver instance could be tricked into clicking on a specifically crafted admin account-switch.php URL that would eventually lead them to another (unsafe) domain, potentially used for stealing credentials or other phishing attacks. This vulnerability was addressed in version 4.2.0."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "Open Redirect (CWE-601)"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.revive-adserver.com/security/revive-sa-2019-001/",
              "refsource": "MISC",
              "url": "https://www.revive-adserver.com/security/revive-sa-2019-001/"
            },
            {
              "name": "https://hackerone.com/reports/390663",
              "refsource": "MISC",
              "url": "https://hackerone.com/reports/390663"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "36234546-b8fa-4601-9d6f-f4e334aa8ea1",
    "assignerShortName": "hackerone",
    "cveId": "CVE-2019-5433",
    "datePublished": "2019-05-06T16:51:54.000Z",
    "dateReserved": "2019-01-04T00:00:00.000Z",
    "dateUpdated": "2024-08-04T19:54:53.436Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "epss": {
      "cve": "CVE-2019-5433",
      "date": "2026-10-27",
      "epss": "0.01675",
      "percentile": "0.76743"
    },
    "nvd": {
      "cve": {
        "configurations": [
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:a:revive-adserver:revive_adserver:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "7D5364E4-F430-47F1-AE03-88C1BCFF30E7",
                    "versionEndExcluding": "4.2.0",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ]
          }
        ],
        "cveTags": [],
        "descriptions": [
          {
            "lang": "en",
            "value": "A user having access to the UI of a Revive Adserver instance could be tricked into clicking on a specifically crafted admin account-switch.php URL that would eventually lead them to another (unsafe) domain, potentially used for stealing credentials or other phishing attacks. This vulnerability was addressed in version 4.2.0."
          },
          {
            "lang": "es",
            "value": "Un usuario que tenga acceso a la interfaz de usuario (UI) de una instancia de Revive Adserver podr\u00eda ser enga\u00f1ado al hacer clic sobre una URL de administrador account-switch.php espec\u00edficamente creada y que eventualmente llevar\u00eda a otro dominio (no seguro), potencialmente utilizado para sustraer credenciales u otros ataques de phishing. Esta vulnerabilidad fue tratada en la versi\u00f3n 4.2.0."
          }
        ],
        "id": "CVE-2019-5433",
        "lastModified": "2024-11-21T04:44:55.587",
        "metrics": {
          "cvssMetricV2": [
            {
              "acInsufInfo": false,
              "baseSeverity": "MEDIUM",
              "cvssData": {
                "accessComplexity": "MEDIUM",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "availabilityImpact": "NONE",
                "baseScore": 5.8,
                "confidentialityImpact": "PARTIAL",
                "integrityImpact": "PARTIAL",
                "vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:N",
                "version": "2.0"
              },
              "exploitabilityScore": 8.6,
              "impactScore": 4.9,
              "obtainAllPrivilege": false,
              "obtainOtherPrivilege": false,
              "obtainUserPrivilege": false,
              "source": "nvd@nist.gov",
              "type": "Primary",
              "userInteractionRequired": true
            }
          ],
          "cvssMetricV30": [
            {
              "cvssData": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "NONE",
                "baseScore": 5.4,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "LOW",
                "integrityImpact": "LOW",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:L/I:L/A:N",
                "version": "3.0"
              },
              "exploitabilityScore": 2.8,
              "impactScore": 2.5,
              "source": "nvd@nist.gov",
              "type": "Primary"
            }
          ]
        },
        "published": "2019-05-06T17:29:00.620",
        "references": [
          {
            "source": "support@hackerone.com",
            "tags": [
              "Exploit",
              "Third Party Advisory"
            ],
            "url": "https://hackerone.com/reports/390663"
          },
          {
            "source": "support@hackerone.com",
            "tags": [
              "Patch",
              "Vendor Advisory"
            ],
            "url": "https://www.revive-adserver.com/security/revive-sa-2019-001/"
          },
          {
            "source": "af854a3a-2127-422b-91ae-364da2661108",
            "tags": [
              "Exploit",
              "Third Party Advisory"
            ],
            "url": "https://hackerone.com/reports/390663"
          },
          {
            "source": "af854a3a-2127-422b-91ae-364da2661108",
            "tags": [
              "Patch",
              "Vendor Advisory"
            ],
            "url": "https://www.revive-adserver.com/security/revive-sa-2019-001/"
          }
        ],
        "sourceIdentifier": "support@hackerone.com",
        "vulnStatus": "Modified",
        "weaknesses": [
          {
            "description": [
              {
                "lang": "en",
                "value": "CWE-601"
              }
            ],
            "source": "support@hackerone.com",
            "type": "Secondary"
          },
          {
            "description": [
              {
                "lang": "en",
                "value": "CWE-601"
              }
            ],
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ]
      }
    }
  }
}



Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Drag nodes to arrange them. Double-click a related vulnerability to open it, or a source to visit its link. The Physics button on the left tunes the layout and the simulation; the legend at the bottom left hides or shows nodes by kind and by sighting type.

Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Vulnerability timeline

Sightings and recorded dates, grouped by day · UTC

JSON
Events included in the timeline

Loading timeline…


    Loading…

    Loading…

    Loading…

    Related by attack behaviour

    Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.