CVE-2019-3747 (GCVE-0-2019-3747)

Vulnerability from cvelistv5 – Published: 2019-09-27 20:21 – Updated: 2024-09-17 00:26
VLAI
Summary
Dell EMC Integrated Data Protection Appliance versions prior to 2.3 contain a stored cross-site scripting vulnerability. A remote malicious ACM admin user may potentially exploit this vulnerability to store malicious HTML or JavaScript code in Cloud DR add-on specific field. When victim users access the page through their browsers, the malicious code gets executed by the web browser in the context of the vulnerable web application.
CWE
  • CWE-79 - Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
References
Impacted products
Vendor Product Version CPE status
Dell Integrated Data Protection Appliance Affected: prior to 2.3
guessed Create a notification for this product.
Date Public
2019-08-08 00:00
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T19:19:17.626Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://www.dell.com/support/security/en-us/details/536363/DSA-2019-112-Dell-EMC-Integrated-Data-Protection-Appliance-Multiple-Vulnerabilities"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Integrated Data Protection Appliance",
          "vendor": "Dell",
          "versions": [
            {
              "status": "affected",
              "version": "prior to 2.3"
            }
          ]
        }
      ],
      "datePublic": "2019-08-08T00:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "value": "Dell EMC Integrated Data Protection Appliance versions prior to 2.3 contain a stored cross-site scripting vulnerability. A remote malicious ACM admin user may potentially exploit this vulnerability to store malicious HTML or JavaScript code in Cloud DR add-on specific field. When victim users access the page through their browsers, the malicious code gets executed by the web browser in the context of the vulnerable web application."
        }
      ],
      "metrics": [
        {
          "cvssV3_0": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 8.4,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "HIGH",
            "scope": "CHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:R/S:C/C:H/I:H/A:H",
            "version": "3.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-79",
              "description": "CWE-79: Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2019-09-27T20:21:21.000Z",
        "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "shortName": "dell"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://www.dell.com/support/security/en-us/details/536363/DSA-2019-112-Dell-EMC-Integrated-Data-Protection-Appliance-Multiple-Vulnerabilities"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "secure@dell.com",
          "DATE_PUBLIC": "2019-08-08",
          "ID": "CVE-2019-3747",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Integrated Data Protection Appliance",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "prior to 2.3"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Dell"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Dell EMC Integrated Data Protection Appliance versions prior to 2.3 contain a stored cross-site scripting vulnerability. A remote malicious ACM admin user may potentially exploit this vulnerability to store malicious HTML or JavaScript code in Cloud DR add-on specific field. When victim users access the page through their browsers, the malicious code gets executed by the web browser in the context of the vulnerable web application."
            }
          ]
        },
        "impact": {
          "cvss": {
            "baseScore": 8.4,
            "baseSeverity": "High",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:R/S:C/C:H/I:H/A:H",
            "version": "3.0"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-79: Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.dell.com/support/security/en-us/details/536363/DSA-2019-112-Dell-EMC-Integrated-Data-Protection-Appliance-Multiple-Vulnerabilities",
              "refsource": "CONFIRM",
              "url": "https://www.dell.com/support/security/en-us/details/536363/DSA-2019-112-Dell-EMC-Integrated-Data-Protection-Appliance-Multiple-Vulnerabilities"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
    "assignerShortName": "dell",
    "cveId": "CVE-2019-3747",
    "datePublished": "2019-09-27T20:21:21.014Z",
    "dateReserved": "2019-01-03T00:00:00.000Z",
    "dateUpdated": "2024-09-17T00:26:31.837Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "epss": {
      "cve": "CVE-2019-3747",
      "date": "2026-10-01",
      "epss": "0.00778",
      "percentile": "0.54244"
    },
    "nvd": {
      "cve": {
        "configurations": [
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:dell:emc_integrated_data_protection_appliance_firmware:2.0:*:*:*:*:*:*:*",
                    "matchCriteriaId": "5C133A08-973B-43E2-8E0C-9B7AEF467BDD",
                    "vulnerable": true
                  },
                  {
                    "criteria": "cpe:2.3:o:dell:emc_integrated_data_protection_appliance_firmware:2.1:*:*:*:*:*:*:*",
                    "matchCriteriaId": "889D0DDB-7D31-4AE9-972A-AE14CC2A82BF",
                    "vulnerable": true
                  },
                  {
                    "criteria": "cpe:2.3:o:dell:emc_integrated_data_protection_appliance_firmware:2.2:*:*:*:*:*:*:*",
                    "matchCriteriaId": "970D60B9-9DAD-4F1D-BFBE-BB069756011C",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:dell:emc_idpa_dp4400:-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "70B89DD8-CEE9-4C3D-828D-71139D55A7C5",
                    "vulnerable": false
                  },
                  {
                    "criteria": "cpe:2.3:h:dell:emc_idpa_dp5800:-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "7FEEA32E-07CD-45F0-AB1E-235764A8A094",
                    "vulnerable": false
                  },
                  {
                    "criteria": "cpe:2.3:h:dell:emc_idpa_dp8300:-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "8C8B35A8-80BF-443E-992B-6F5B03A9928C",
                    "vulnerable": false
                  },
                  {
                    "criteria": "cpe:2.3:h:dell:emc_idpa_dp8800:-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "E98F97BD-57F5-4F2E-9573-863503A5B911",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          }
        ],
        "cveTags": [],
        "descriptions": [
          {
            "lang": "en",
            "value": "Dell EMC Integrated Data Protection Appliance versions prior to 2.3 contain a stored cross-site scripting vulnerability. A remote malicious ACM admin user may potentially exploit this vulnerability to store malicious HTML or JavaScript code in Cloud DR add-on specific field. When victim users access the page through their browsers, the malicious code gets executed by the web browser in the context of the vulnerable web application."
          },
          {
            "lang": "es",
            "value": "Dell EMC Integrated Data Protection Appliance versiones  anteriores a 2.3, contienen una vulnerabilidad de tipo cross-site scripting almacenado. Un usuario administrador de ACM malicioso remoto puede explotar esta vulnerabilidad para almacenar c\u00f3digo HTML o JavaScript malicioso en el campo espec\u00edfico del add-on Cloud DR. Cuando los usuarios v\u00edctimas acceden a la p\u00e1gina por medio de sus navegadores, el c\u00f3digo malicioso es ejecutado por el navegador en el contexto de la aplicaci\u00f3n web vulnerable."
          }
        ],
        "id": "CVE-2019-3747",
        "lastModified": "2024-11-21T04:42:27.437",
        "metrics": {
          "cvssMetricV2": [
            {
              "acInsufInfo": false,
              "baseSeverity": "LOW",
              "cvssData": {
                "accessComplexity": "MEDIUM",
                "accessVector": "NETWORK",
                "authentication": "SINGLE",
                "availabilityImpact": "NONE",
                "baseScore": 3.5,
                "confidentialityImpact": "NONE",
                "integrityImpact": "PARTIAL",
                "vectorString": "AV:N/AC:M/Au:S/C:N/I:P/A:N",
                "version": "2.0"
              },
              "exploitabilityScore": 6.8,
              "impactScore": 2.9,
              "obtainAllPrivilege": false,
              "obtainOtherPrivilege": false,
              "obtainUserPrivilege": false,
              "source": "nvd@nist.gov",
              "type": "Primary",
              "userInteractionRequired": true
            }
          ],
          "cvssMetricV30": [
            {
              "cvssData": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 8.4,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "HIGH",
                "scope": "CHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:R/S:C/C:H/I:H/A:H",
                "version": "3.0"
              },
              "exploitabilityScore": 1.7,
              "impactScore": 6.0,
              "source": "security_alert@emc.com",
              "type": "Secondary"
            }
          ],
          "cvssMetricV31": [
            {
              "cvssData": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "NONE",
                "baseScore": 4.8,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "LOW",
                "integrityImpact": "LOW",
                "privilegesRequired": "HIGH",
                "scope": "CHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:N",
                "version": "3.1"
              },
              "exploitabilityScore": 1.7,
              "impactScore": 2.7,
              "source": "nvd@nist.gov",
              "type": "Primary"
            }
          ]
        },
        "published": "2019-09-27T21:15:10.207",
        "references": [
          {
            "source": "security_alert@emc.com",
            "tags": [
              "Vendor Advisory"
            ],
            "url": "https://www.dell.com/support/security/en-us/details/536363/DSA-2019-112-Dell-EMC-Integrated-Data-Protection-Appliance-Multiple-Vulnerabilities"
          },
          {
            "source": "af854a3a-2127-422b-91ae-364da2661108",
            "tags": [
              "Vendor Advisory"
            ],
            "url": "https://www.dell.com/support/security/en-us/details/536363/DSA-2019-112-Dell-EMC-Integrated-Data-Protection-Appliance-Multiple-Vulnerabilities"
          }
        ],
        "sourceIdentifier": "security_alert@emc.com",
        "vulnStatus": "Modified",
        "weaknesses": [
          {
            "description": [
              {
                "lang": "en",
                "value": "CWE-79"
              }
            ],
            "source": "security_alert@emc.com",
            "type": "Secondary"
          },
          {
            "description": [
              {
                "lang": "en",
                "value": "CWE-79"
              }
            ],
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ]
      }
    }
  }
}



Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.

Loading…

Loading…

Loading…

Related by attack behaviour

Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.


Loading…