CVE-2019-20466 (GCVE-0-2019-20466)
Vulnerability from cvelistv5 – Published: 2021-04-02 15:37 – Updated: 2024-08-05 02:39
VLAI
Summary
An issue was discovered on Sannce Smart HD Wifi Security Camera EAN 2 950004 595317 devices. A local attacker with the "default" account is capable of reading the /etc/passwd file, which contains a weakly hashed root password. By taking this hash and cracking it, the attacker can obtain root rights on the device.
Severity
7.8 (High)
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
- n/a
- CWE-916 - Use of Password Hash With Insufficient Computational Effort
Assigner
References
2 references
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| sannce | smart_hd_wifi_security_camera_ean_2_950004_595317_firmware |
Affected:
0 , < *
(custom)
cpe:2.3:h:sannce:smart_hd_wifi_security_camera_ean_2_950004_595317:-:*:*:*:*:*:*:* cpe:2.3:o:sannce:smart_hd_wifi_security_camera_ean_2_950004_595317_firmware:-:*:*:*:*:*:*:* |
Date Public
2021-03-30 00:00
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:h:sannce:smart_hd_wifi_security_camera_ean_2_950004_595317:-:*:*:*:*:*:*:*",
"cpe:2.3:o:sannce:smart_hd_wifi_security_camera_ean_2_950004_595317_firmware:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "smart_hd_wifi_security_camera_ean_2_950004_595317_firmware",
"vendor": "sannce",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2019-20466",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-07-30T13:53:31.700735Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-916",
"description": "CWE-916 Use of Password Hash With Insufficient Computational Effort",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-07-30T13:58:43.651Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-05T02:39:09.901Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://www.eurofins-cybersecurity.com/news/connected-devices-baby-monitors-part-2/"
},
{
"name": "20240729 Bunch of IoT CVEs",
"tags": [
"mailing-list",
"x_transferred"
],
"url": "http://seclists.org/fulldisclosure/2024/Jul/14"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"datePublic": "2021-03-30T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "An issue was discovered on Sannce Smart HD Wifi Security Camera EAN 2 950004 595317 devices. A local attacker with the \"default\" account is capable of reading the /etc/passwd file, which contains a weakly hashed root password. By taking this hash and cracking it, the attacker can obtain root rights on the device."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-07-30T00:07:40.792Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"url": "https://www.eurofins-cybersecurity.com/news/connected-devices-baby-monitors-part-2/"
},
{
"name": "20240729 Bunch of IoT CVEs",
"tags": [
"mailing-list"
],
"url": "http://seclists.org/fulldisclosure/2024/Jul/14"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2019-20466",
"datePublished": "2021-04-02T15:37:05.000Z",
"dateReserved": "2020-02-17T00:00:00.000Z",
"dateUpdated": "2024-08-05T02:39:09.901Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"epss": {
"cve": "CVE-2019-20466",
"date": "2026-07-01",
"epss": "0.00346",
"percentile": "0.26559"
},
"nvd": "{\"cve\":{\"id\":\"CVE-2019-20466\",\"sourceIdentifier\":\"cve@mitre.org\",\"published\":\"2021-04-02T16:15:13.193\",\"lastModified\":\"2024-11-21T04:38:32.987\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"An issue was discovered on Sannce Smart HD Wifi Security Camera EAN 2 950004 595317 devices. A local attacker with the \\\"default\\\" account is capable of reading the /etc/passwd file, which contains a weakly hashed root password. By taking this hash and cracking it, the attacker can obtain root rights on the device.\"},{\"lang\":\"es\",\"value\":\"Se detect\u00f3 un problema en los dispositivos Sannce Smart HD Wifi Security Camera EAN 2 950004 595317.\u0026#xa0;Un atacante local con la cuenta \\\"default\\\" es capaz de leer el archivo /etc/passwd, que contiene una contrase\u00f1a de root con un hash d\u00e9bil.\u0026#xa0;Al tomar este hash y descifrarlo, el atacante puede obtener derechos de root en el dispositivo.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":7.8,\"baseSeverity\":\"HIGH\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":1.8,\"impactScore\":5.9},{\"source\":\"134c704f-9b21-4f2e-91b3-4a467353bcc0\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":7.8,\"baseSeverity\":\"HIGH\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":1.8,\"impactScore\":5.9}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:L/AC:L/Au:N/C:C/I:C/A:C\",\"baseScore\":7.2,\"accessVector\":\"LOCAL\",\"accessComplexity\":\"LOW\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"COMPLETE\",\"integrityImpact\":\"COMPLETE\",\"availabilityImpact\":\"COMPLETE\"},\"baseSeverity\":\"HIGH\",\"exploitabilityScore\":3.9,\"impactScore\":10.0,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-916\"}]},{\"source\":\"134c704f-9b21-4f2e-91b3-4a467353bcc0\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-916\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:sannce:smart_hd_wifi_security_camera_ean_2_950004_595317_firmware:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"8123D4F3-B94B-405B-9FF5-0CA27A0B719E\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:sannce:smart_hd_wifi_security_camera_ean_2_950004_595317:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"548EDA0C-3BBF-44AF-99DC-73796B27874D\"}]}]}],\"references\":[{\"url\":\"http://seclists.org/fulldisclosure/2024/Jul/14\",\"source\":\"cve@mitre.org\"},{\"url\":\"https://www.eurofins-cybersecurity.com/news/connected-devices-baby-monitors-part-2/\",\"source\":\"cve@mitre.org\",\"tags\":[\"Exploit\",\"Third Party Advisory\"]},{\"url\":\"http://seclists.org/fulldisclosure/2024/Jul/14\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\"},{\"url\":\"https://www.eurofins-cybersecurity.com/news/connected-devices-baby-monitors-part-2/\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Exploit\",\"Third Party Advisory\"]}]}}",
"vulnrichment": {
"containers": "{\"adp\": [{\"title\": \"CVE Program Container\", \"references\": [{\"url\": \"https://www.eurofins-cybersecurity.com/news/connected-devices-baby-monitors-part-2/\", \"tags\": [\"x_transferred\"]}, {\"url\": \"http://seclists.org/fulldisclosure/2024/Jul/14\", \"name\": \"20240729 Bunch of IoT CVEs\", \"tags\": [\"mailing-list\", \"x_transferred\"]}], \"providerMetadata\": {\"orgId\": \"af854a3a-2127-422b-91ae-364da2661108\", \"shortName\": \"CVE\", \"dateUpdated\": \"2024-08-05T02:39:09.901Z\"}}, {\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"cvssV3_1\": {\"scope\": \"UNCHANGED\", \"version\": \"3.1\", \"baseScore\": 7.8, \"attackVector\": \"LOCAL\", \"baseSeverity\": \"HIGH\", \"vectorString\": \"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H\", \"integrityImpact\": \"HIGH\", \"userInteraction\": \"NONE\", \"attackComplexity\": \"LOW\", \"availabilityImpact\": \"HIGH\", \"privilegesRequired\": \"LOW\", \"confidentialityImpact\": \"HIGH\"}}, {\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2019-20466\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"no\"}, {\"Technical Impact\": \"total\"}], \"version\": \"2.0.3\", \"timestamp\": \"2024-07-30T13:53:31.700735Z\"}}}], \"affected\": [{\"cpes\": [\"cpe:2.3:h:sannce:smart_hd_wifi_security_camera_ean_2_950004_595317:-:*:*:*:*:*:*:*\", \"cpe:2.3:o:sannce:smart_hd_wifi_security_camera_ean_2_950004_595317_firmware:-:*:*:*:*:*:*:*\"], \"vendor\": \"sannce\", \"product\": \"smart_hd_wifi_security_camera_ean_2_950004_595317_firmware\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"*\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-916\", \"description\": \"CWE-916 Use of Password Hash With Insufficient Computational Effort\"}]}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2024-07-30T13:55:12.800Z\"}}], \"cna\": {\"affected\": [{\"vendor\": \"n/a\", \"product\": \"n/a\", \"versions\": [{\"status\": \"affected\", \"version\": \"n/a\"}]}], \"datePublic\": \"2021-03-30T00:00:00.000Z\", \"references\": [{\"url\": \"https://www.eurofins-cybersecurity.com/news/connected-devices-baby-monitors-part-2/\"}, {\"url\": \"http://seclists.org/fulldisclosure/2024/Jul/14\", \"name\": \"20240729 Bunch of IoT CVEs\", \"tags\": [\"mailing-list\"]}], \"descriptions\": [{\"lang\": \"en\", \"value\": \"An issue was discovered on Sannce Smart HD Wifi Security Camera EAN 2 950004 595317 devices. A local attacker with the \\\"default\\\" account is capable of reading the /etc/passwd file, which contains a weakly hashed root password. By taking this hash and cracking it, the attacker can obtain root rights on the device.\"}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"text\", \"description\": \"n/a\"}]}], \"providerMetadata\": {\"orgId\": \"8254265b-2729-46b6-b9e3-3dfca2d5bfca\", \"shortName\": \"mitre\", \"dateUpdated\": \"2024-07-30T00:07:40.792Z\"}}}",
"cveMetadata": "{\"cveId\": \"CVE-2019-20466\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2024-08-05T02:39:09.901Z\", \"dateReserved\": \"2020-02-17T00:00:00.000Z\", \"assignerOrgId\": \"8254265b-2729-46b6-b9e3-3dfca2d5bfca\", \"datePublished\": \"2021-04-02T15:37:05.000Z\", \"assignerShortName\": \"mitre\"}",
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
}
}
Loading…
Loading…
Experimental. This forecast is provided for visualization only and may change without notice. Do not use it for operational decisions.
Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…