CVE-2019-11326 (GCVE-0-2019-11326)
Vulnerability from cvelistv5 – Published: 2019-09-20 18:19 – Updated: 2024-08-04 22:48
VLAI
EPSS
VEX
Summary
An issue was discovered on Topcon Positioning Net-G5 GNSS Receiver devices with firmware 5.2.2. The web interface of the product is protected by a login. A guest is allowed to login. Once logged in as a guest, an attacker can browse a URL to read the password of the administrative user. The same procedure allows a regular user to gain administrative privileges. The guest login is possible in the default configuration.
Severity
8.8 (High)
CWE
- n/a
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://mezdanak.de/2019/06/21/iot-full-disclosur… | x_refsource_MISC |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T22:48:09.094Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://mezdanak.de/2019/06/21/iot-full-disclosure-topcon-positioning-net-g5-receiver/"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "An issue was discovered on Topcon Positioning Net-G5 GNSS Receiver devices with firmware 5.2.2. The web interface of the product is protected by a login. A guest is allowed to login. Once logged in as a guest, an attacker can browse a URL to read the password of the administrative user. The same procedure allows a regular user to gain administrative privileges. The guest login is possible in the default configuration."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2019-09-20T18:19:07.000Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://mezdanak.de/2019/06/21/iot-full-disclosure-topcon-positioning-net-g5-receiver/"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2019-11326",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "An issue was discovered on Topcon Positioning Net-G5 GNSS Receiver devices with firmware 5.2.2. The web interface of the product is protected by a login. A guest is allowed to login. Once logged in as a guest, an attacker can browse a URL to read the password of the administrative user. The same procedure allows a regular user to gain administrative privileges. The guest login is possible in the default configuration."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://mezdanak.de/2019/06/21/iot-full-disclosure-topcon-positioning-net-g5-receiver/",
"refsource": "MISC",
"url": "https://mezdanak.de/2019/06/21/iot-full-disclosure-topcon-positioning-net-g5-receiver/"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2019-11326",
"datePublished": "2019-09-20T18:19:08.000Z",
"dateReserved": "2019-04-18T00:00:00.000Z",
"dateUpdated": "2024-08-04T22:48:09.094Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"epss": {
"cve": "CVE-2019-11326",
"date": "2026-07-16",
"epss": "0.0123",
"percentile": "0.65521"
},
"nvd": "{\"cve\":{\"id\":\"CVE-2019-11326\",\"sourceIdentifier\":\"cve@mitre.org\",\"published\":\"2019-09-20T19:15:11.487\",\"lastModified\":\"2024-11-21T04:20:53.650\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"An issue was discovered on Topcon Positioning Net-G5 GNSS Receiver devices with firmware 5.2.2. The web interface of the product is protected by a login. A guest is allowed to login. Once logged in as a guest, an attacker can browse a URL to read the password of the administrative user. The same procedure allows a regular user to gain administrative privileges. The guest login is possible in the default configuration.\"},{\"lang\":\"es\",\"value\":\"Se detect\u00f3 un problema en los dispositivos Topcon Positioning Net-G5 GNSS Receiver con versi\u00f3n de firmware 5.2.2. La interfaz web del producto est\u00e1 protegida mediante un inicio de sesi\u00f3n. Un invitado puede iniciar sesi\u00f3n. Una vez registrado como invitado, un atacante puede explorar una URL para leer la contrase\u00f1a del usuario administrativo. El mismo procedimiento permite a un usuario regular alcanzar privilegios administrativos. El inicio de sesi\u00f3n del invitado es posible en la configuraci\u00f3n predeterminada.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":8.8,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":2.8,\"impactScore\":5.9}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:L/Au:S/C:P/I:P/A:P\",\"baseScore\":6.5,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"LOW\",\"authentication\":\"SINGLE\",\"confidentialityImpact\":\"PARTIAL\",\"integrityImpact\":\"PARTIAL\",\"availabilityImpact\":\"PARTIAL\"},\"baseSeverity\":\"MEDIUM\",\"exploitabilityScore\":8.0,\"impactScore\":6.4,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-425\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:topcon:net-g5_firmware:5.2.2:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"6CFEFC2C-437F-4DEF-B719-6DAD6CA84A7F\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:topcon:net-g5:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"4E6938C5-430F-41A6-AEE0-40E460D1C94A\"}]}]}],\"references\":[{\"url\":\"https://mezdanak.de/2019/06/21/iot-full-disclosure-topcon-positioning-net-g5-receiver/\",\"source\":\"cve@mitre.org\",\"tags\":[\"Third Party Advisory\"]},{\"url\":\"https://mezdanak.de/2019/06/21/iot-full-disclosure-topcon-positioning-net-g5-receiver/\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Third Party Advisory\"]}]}}"
}
}
Loading…
Loading…
Experimental. This forecast is provided for visualization only and may change without notice. Do not use it for operational decisions.
Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…