Code injection vulnerability in the installer for Intel(R) USB 3.0 eXtensible Host Controller Driver for Microsoft Windows 7 before version 5.0.4.43v2 may allow a user to potentially enable escalation of privilege via local access.
Severity
6.7 (Medium)
CWE
- n/a
Assigner
References
2 references
| URL | Tags |
|---|---|
| http://www.securityfocus.com/bid/107073 | vdb-entryx_refsource_BID |
| https://www.intel.com/content/www/us/en/security-… | x_refsource_CONFIRM |
Date Public
2019-02-12 00:00
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T04:50:30.656Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "107073",
"tags": [
"vdb-entry",
"x_refsource_BID",
"x_transferred"
],
"url": "http://www.securityfocus.com/bid/107073"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://www.intel.com/content/www/us/en/security-center/advisory/INTEL-SA-00200.html"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"datePublic": "2019-02-12T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "Code injection vulnerability in the installer for Intel(R) USB 3.0 eXtensible Host Controller Driver for Microsoft Windows 7 before version 5.0.4.43v2 may allow a user to potentially enable escalation of privilege via local access."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2019-02-20T10:57:01.000Z",
"orgId": "6dda929c-bb53-4a77-a76d-48e79601a1ce",
"shortName": "intel"
},
"references": [
{
"name": "107073",
"tags": [
"vdb-entry",
"x_refsource_BID"
],
"url": "http://www.securityfocus.com/bid/107073"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://www.intel.com/content/www/us/en/security-center/advisory/INTEL-SA-00200.html"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "secure@intel.com",
"DATE_PUBLIC": "2019-02-12T00:00:00",
"ID": "CVE-2018-3700",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Code injection vulnerability in the installer for Intel(R) USB 3.0 eXtensible Host Controller Driver for Microsoft Windows 7 before version 5.0.4.43v2 may allow a user to potentially enable escalation of privilege via local access."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "107073",
"refsource": "BID",
"url": "http://www.securityfocus.com/bid/107073"
},
{
"name": "https://www.intel.com/content/www/us/en/security-center/advisory/INTEL-SA-00200.html",
"refsource": "CONFIRM",
"url": "https://www.intel.com/content/www/us/en/security-center/advisory/INTEL-SA-00200.html"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "6dda929c-bb53-4a77-a76d-48e79601a1ce",
"assignerShortName": "intel",
"cveId": "CVE-2018-3700",
"datePublished": "2019-02-18T17:00:00.000Z",
"dateReserved": "2017-12-28T00:00:00.000Z",
"dateUpdated": "2024-09-16T22:35:13.239Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"epss": {
"cve": "CVE-2018-3700",
"date": "2026-07-16",
"epss": "0.00511",
"percentile": "0.40139"
},
"nvd": "{\"cve\":{\"id\":\"CVE-2018-3700\",\"sourceIdentifier\":\"secure@intel.com\",\"published\":\"2019-02-18T17:29:00.330\",\"lastModified\":\"2024-11-21T04:05:54.773\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"Code injection vulnerability in the installer for Intel(R) USB 3.0 eXtensible Host Controller Driver for Microsoft Windows 7 before version 5.0.4.43v2 may allow a user to potentially enable escalation of privilege via local access.\"},{\"lang\":\"es\",\"value\":\"Una vulnerabilidad de inyecci\u00f3n de c\u00f3digo en el instalador para el controlador de host Intel \u00ae USB 3.0 eXtensible para Microsoft Windows 7, en versiones anteriores a la 5.0.4.43v2, podr\u00eda permitir a un usuario habilitar un escalado de privilegios mediante un acceso local.\"}],\"metrics\":{\"cvssMetricV30\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.0\",\"vectorString\":\"CVSS:3.0/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":6.7,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"HIGH\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":0.8,\"impactScore\":5.9}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:L/AC:L/Au:N/C:P/I:P/A:P\",\"baseScore\":4.6,\"accessVector\":\"LOCAL\",\"accessComplexity\":\"LOW\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"PARTIAL\",\"integrityImpact\":\"PARTIAL\",\"availabilityImpact\":\"PARTIAL\"},\"baseSeverity\":\"MEDIUM\",\"exploitabilityScore\":3.9,\"impactScore\":6.4,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-94\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:intel:usb_3.0_extensible_host_controller_driver:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"5.0.4.43v2\",\"matchCriteriaId\":\"49AD51AF-C7AE-4B02-866C-8BA7EB95D443\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:o:microsoft:windows_7:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"E33796DB-4523-4F04-B564-ADF030553D51\"}]}]}],\"references\":[{\"url\":\"http://www.securityfocus.com/bid/107073\",\"source\":\"secure@intel.com\",\"tags\":[\"Third Party Advisory\"]},{\"url\":\"https://www.intel.com/content/www/us/en/security-center/advisory/INTEL-SA-00200.html\",\"source\":\"secure@intel.com\",\"tags\":[\"Patch\",\"Vendor Advisory\"]},{\"url\":\"http://www.securityfocus.com/bid/107073\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Third Party Advisory\"]},{\"url\":\"https://www.intel.com/content/www/us/en/security-center/advisory/INTEL-SA-00200.html\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Patch\",\"Vendor Advisory\"]}]}}"
}
}
Loading…
Loading…
Experimental. This forecast is provided for visualization only and may change without notice. Do not use it for operational decisions.
Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…