CVE-2018-0295 (GCVE-0-2018-0295)
Vulnerability from cvelistv5 – Published: 2018-06-20 21:00 – Updated: 2024-11-29 15:02| URL | Tags |
|---|---|
| https://tools.cisco.com/security/center/content/C… | x_refsource_CONFIRM |
| http://www.securitytracker.com/id/1041169 | vdb-entryx_refsource_SECTRACK |
| Vendor | Product | Version | CPE status | |
|---|---|---|---|---|
| n/a | Cisco NX-OS unknown |
Affected:
Cisco NX-OS unknown
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T03:21:15.489Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20180620-nxosbgp"
},
{
"name": "1041169",
"tags": [
"vdb-entry",
"x_refsource_SECTRACK",
"x_transferred"
],
"url": "http://www.securitytracker.com/id/1041169"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2018-0295",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-11-29T14:43:43.333193Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-11-29T15:02:09.803Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "Cisco NX-OS unknown",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "Cisco NX-OS unknown"
}
]
}
],
"datePublic": "2018-06-20T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "A vulnerability in the Border Gateway Protocol (BGP) implementation of Cisco NX-OS Software could allow an unauthenticated, remote attacker to cause a denial of service (DoS) condition due to the device unexpectedly reloading. The vulnerability is due to incomplete input validation of the BGP update messages. An attacker could exploit this vulnerability by sending a crafted BGP update message to the targeted device. An exploit could allow the attacker to cause the switch to reload unexpectedly. The Cisco implementation of the BGP protocol only accepts incoming BGP traffic from explicitly defined peers. To exploit this vulnerability, an attacker must be able to send the malicious packets over a TCP connection that appears to come from a trusted BGP peer or inject malformed messages into the victim\u0027s BGP network. This would require obtaining information about the BGP peers in the affected system\u0027s trusted network. The vulnerability may be triggered when the router receives a malformed BGP message from a peer on an existing BGP session. At least one BGP neighbor session must be established for a router to be vulnerable. This vulnerability affects Nexus 2000 Series Switches, Nexus 3000 Series Switches, Nexus 3500 Platform Switches, Nexus 3600 Platform Switches, Nexus 5500 Platform Switches, Nexus 5600 Platform Switches, Nexus 6000 Series Switches, Nexus 7000 Series Switches, Nexus 7700 Series Switches, Nexus 9000 Series Fabric Switches in Application Centric Infrastructure (ACI) mode, Nexus 9000 Series Switches in standalone NX-OS mode, Nexus 9500 R-Series Line Cards and Fabric Modules. Cisco Bug IDs: CSCve79599, CSCve87784, CSCve91371, CSCve91387."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-20",
"description": "CWE-20",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2018-06-23T09:57:01.000Z",
"orgId": "d1c1063e-7a18-46af-9102-31f8928bc633",
"shortName": "cisco"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20180620-nxosbgp"
},
{
"name": "1041169",
"tags": [
"vdb-entry",
"x_refsource_SECTRACK"
],
"url": "http://www.securitytracker.com/id/1041169"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "psirt@cisco.com",
"ID": "CVE-2018-0295",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Cisco NX-OS unknown",
"version": {
"version_data": [
{
"version_value": "Cisco NX-OS unknown"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A vulnerability in the Border Gateway Protocol (BGP) implementation of Cisco NX-OS Software could allow an unauthenticated, remote attacker to cause a denial of service (DoS) condition due to the device unexpectedly reloading. The vulnerability is due to incomplete input validation of the BGP update messages. An attacker could exploit this vulnerability by sending a crafted BGP update message to the targeted device. An exploit could allow the attacker to cause the switch to reload unexpectedly. The Cisco implementation of the BGP protocol only accepts incoming BGP traffic from explicitly defined peers. To exploit this vulnerability, an attacker must be able to send the malicious packets over a TCP connection that appears to come from a trusted BGP peer or inject malformed messages into the victim\u0027s BGP network. This would require obtaining information about the BGP peers in the affected system\u0027s trusted network. The vulnerability may be triggered when the router receives a malformed BGP message from a peer on an existing BGP session. At least one BGP neighbor session must be established for a router to be vulnerable. This vulnerability affects Nexus 2000 Series Switches, Nexus 3000 Series Switches, Nexus 3500 Platform Switches, Nexus 3600 Platform Switches, Nexus 5500 Platform Switches, Nexus 5600 Platform Switches, Nexus 6000 Series Switches, Nexus 7000 Series Switches, Nexus 7700 Series Switches, Nexus 9000 Series Fabric Switches in Application Centric Infrastructure (ACI) mode, Nexus 9000 Series Switches in standalone NX-OS mode, Nexus 9500 R-Series Line Cards and Fabric Modules. Cisco Bug IDs: CSCve79599, CSCve87784, CSCve91371, CSCve91387."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-20"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20180620-nxosbgp",
"refsource": "CONFIRM",
"url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20180620-nxosbgp"
},
{
"name": "1041169",
"refsource": "SECTRACK",
"url": "http://www.securitytracker.com/id/1041169"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "d1c1063e-7a18-46af-9102-31f8928bc633",
"assignerShortName": "cisco",
"cveId": "CVE-2018-0295",
"datePublished": "2018-06-20T21:00:00.000Z",
"dateReserved": "2017-11-27T00:00:00.000Z",
"dateUpdated": "2024-11-29T15:02:09.803Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"epss": {
"cve": "CVE-2018-0295",
"date": "2026-11-15",
"epss": "0.02418",
"percentile": "0.84426"
},
"nvd": {
"cve": {
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:cisco:nx-os:*:*:*:*:*:*:*:*",
"matchCriteriaId": "D75479AD-9847-497C-9438-AA82D91B6F71",
"versionEndExcluding": "7.3\\(3\\)n1\\(1\\)",
"versionStartIncluding": "6.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:cisco:nexus_5000:-:*:*:*:*:*:*:*",
"matchCriteriaId": "4F2B1E07-8519-4F58-9048-81ABA12E01DC",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:cisco:nexus_5010:-:*:*:*:*:*:*:*",
"matchCriteriaId": "E275D31F-4FA1-428E-AB4A-D2802FF0CF1A",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:cisco:nexus_5020:-:*:*:*:*:*:*:*",
"matchCriteriaId": "BA7F5823-41A8-47C8-A154-02C6C31EF76A",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:cisco:nexus_5548p:-:*:*:*:*:*:*:*",
"matchCriteriaId": "E5519EA9-1236-4F51-9974-E3FC1B26B5D2",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:cisco:nexus_5548up:-:*:*:*:*:*:*:*",
"matchCriteriaId": "CB0A3B06-8B25-4CD3-AFA9-5F928B1042F4",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:cisco:nexus_5596t:-:*:*:*:*:*:*:*",
"matchCriteriaId": "1766443C-1C5A-486E-A36F-D3045F364D78",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:cisco:nexus_5596up:-:*:*:*:*:*:*:*",
"matchCriteriaId": "DC4D4403-F93B-4CC8-B75F-7A5B03FEDD85",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:cisco:nexus_56128p:-:*:*:*:*:*:*:*",
"matchCriteriaId": "ABB6E612-4246-4408-B3F6-B31E771F5ACB",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:cisco:nexus_5624q:-:*:*:*:*:*:*:*",
"matchCriteriaId": "91B129B2-2B31-4DE0-9F83-CC6E0C8729A0",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:cisco:nexus_5648q:-:*:*:*:*:*:*:*",
"matchCriteriaId": "3CBD3CD0-B542-4B23-9C9D-061643BE44E8",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:cisco:nexus_5672up:-:*:*:*:*:*:*:*",
"matchCriteriaId": "A22A2647-A4C0-4681-BBC5-D95ADBAA0457",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:cisco:nexus_5696q:-:*:*:*:*:*:*:*",
"matchCriteriaId": "B2BB1A3A-668C-4B0D-8AC2-6B4758B3420B",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:cisco:nx-os:*:*:*:*:*:*:*:*",
"matchCriteriaId": "B6004E45-878B-4034-AD67-8D2CCB01E9B6",
"versionEndExcluding": "8.1\\(2\\)",
"versionStartIncluding": "6.2",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:cisco:nexus_7000:-:*:*:*:*:*:*:*",
"matchCriteriaId": "12180BEB-7F21-4FA7-ABD2-E9A8EA7340F3",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:cisco:nexus_7700:-:*:*:*:*:*:*:*",
"matchCriteriaId": "DD7A4B4B-3BB1-4A4D-911E-C4EEF01BBC45",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:cisco:nx-os:*:*:*:*:*:*:*:*",
"matchCriteriaId": "93C9AFED-1347-4B0E-B031-AF5EA891B9BD",
"versionEndExcluding": "7.0\\(3\\)i3",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:cisco:nx-os:*:*:*:*:*:*:*:*",
"matchCriteriaId": "15C899EF-A64F-4FD8-851C-1D4E2929BAF4",
"versionEndExcluding": "7.0\\(3\\)i7\\(1\\)",
"versionStartIncluding": "7.0\\(3\\)i4",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:cisco:nexus_92160yc-x:-:*:*:*:*:*:*:*",
"matchCriteriaId": "4283E433-7F8C-4410-B565-471415445811",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:cisco:nexus_92304qc:-:*:*:*:*:*:*:*",
"matchCriteriaId": "D5B2E4C1-2627-4B9D-8E92-4B483F647651",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:cisco:nexus_9236c:-:*:*:*:*:*:*:*",
"matchCriteriaId": "11411BFD-3F4D-4309-AB35-A3629A360FB0",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:cisco:nexus_9272q:-:*:*:*:*:*:*:*",
"matchCriteriaId": "E663DE91-C86D-48DC-B771-FA72A8DF7A7C",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:cisco:nexus_93108tc-ex:-:*:*:*:*:*:*:*",
"matchCriteriaId": "A90184B3-C82F-4CE5-B2AD-97D5E4690871",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:cisco:nexus_93120tx:-:*:*:*:*:*:*:*",
"matchCriteriaId": "07DE6F63-2C7D-415B-8C34-01EC05C062F3",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:cisco:nexus_93128tx:-:*:*:*:*:*:*:*",
"matchCriteriaId": "F423E45D-A6DD-4305-9C6A-EAB26293E53A",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:cisco:nexus_93180yc-ex:-:*:*:*:*:*:*:*",
"matchCriteriaId": "F70D81F1-8B12-4474-9060-B4934D8A3873",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:cisco:nexus_9332pq:-:*:*:*:*:*:*:*",
"matchCriteriaId": "113772B6-E9D2-4094-9468-3F4E1A87D07D",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:cisco:nexus_9372px:-:*:*:*:*:*:*:*",
"matchCriteriaId": "4364ADB9-8162-451D-806A-B98924E6B2CF",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:cisco:nexus_9372tx:-:*:*:*:*:*:*:*",
"matchCriteriaId": "49E0371B-FDE2-473C-AA59-47E1269D050F",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:cisco:nexus_9396px:-:*:*:*:*:*:*:*",
"matchCriteriaId": "1BC5293E-F2B4-46DC-85DA-167EA323FCFD",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:cisco:nexus_9396tx:-:*:*:*:*:*:*:*",
"matchCriteriaId": "EA022E77-6557-4A33-9A3A-D028E2DB669A",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:cisco:nexus_9504:-:*:*:*:*:*:*:*",
"matchCriteriaId": "768BE390-5ED5-48A7-9E80-C4DE8BA979B1",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:cisco:nexus_9508:-:*:*:*:*:*:*:*",
"matchCriteriaId": "DDC2F709-AFBE-48EA-A3A2-DA1134534FB6",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:cisco:nexus_9516:-:*:*:*:*:*:*:*",
"matchCriteriaId": "7E02DC82-0D26-436F-BA64-73C958932B0A",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:cisco:nexus_n9k-c9508-fm-r:-:*:*:*:*:*:*:*",
"matchCriteriaId": "0FD46BDD-4755-46DD-9F83-B2B589B09417",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:cisco:nexus_n9k-x9636c-r:-:*:*:*:*:*:*:*",
"matchCriteriaId": "0603E231-14E0-4224-898F-ED61641F7403",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:cisco:nexus_n9k-x9636q-r:-:*:*:*:*:*:*:*",
"matchCriteriaId": "FE3EB1F2-F964-4D4E-BDE7-8E6805105152",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:cisco:nx-os:*:*:*:*:*:*:*:*",
"matchCriteriaId": "34CF5006-23A1-4B93-8AC6-D97ABB0C2F15",
"versionEndExcluding": "7.0\\(3\\)i4",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:cisco:nx-os:*:*:*:*:*:*:*:*",
"matchCriteriaId": "DDF419AC-58CA-44DD-A036-F85AC8A7FC35",
"versionEndExcluding": "7.0\\(3\\)i6\\(2\\)",
"versionStartIncluding": "7.0\\(3\\)i5",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:cisco:nx-os:7.0\\(3\\)i7:*:*:*:*:*:*:*",
"matchCriteriaId": "5DEBF467-C2E2-4ED9-8E8A-02E062E734D9",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:cisco:nexus_172tq-xl:-:*:*:*:*:*:*:*",
"matchCriteriaId": "38AC6D08-C547-44A3-AC77-A63DB58E4889",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:cisco:nexus_3016:-:*:*:*:*:*:*:*",
"matchCriteriaId": "528ED62B-D739-4E06-AC64-B506FD73BBAB",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:cisco:nexus_3048:-:*:*:*:*:*:*:*",
"matchCriteriaId": "FC2A6C31-438A-4CF5-A3F3-364B1672EB7D",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:cisco:nexus_3064-32t:-:*:*:*:*:*:*:*",
"matchCriteriaId": "09AC2BAD-F536-48D0-A2F0-D4E290519EB6",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:cisco:nexus_3064-t:-:*:*:*:*:*:*:*",
"matchCriteriaId": "65CB7F6D-A82B-4A31-BFAC-FF4A4B8DF9C1",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:cisco:nexus_3064-x:-:*:*:*:*:*:*:*",
"matchCriteriaId": "ECC4FFCC-E886-49BC-9737-5B5BA2AAB14B",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:cisco:nexus_3100-v:-:*:*:*:*:*:*:*",
"matchCriteriaId": "A8FF2EC4-0C09-4C00-9956-A2A4A894F63D",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:cisco:nexus_31128pq:-:*:*:*:*:*:*:*",
"matchCriteriaId": "F4226DA0-9371-401C-8247-E6E636A116C3",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:cisco:nexus_3132c-z:-:*:*:*:*:*:*:*",
"matchCriteriaId": "7664666F-BCE4-4799-AEEA-3A73E6AD33F4",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:cisco:nexus_3132q:-:*:*:*:*:*:*:*",
"matchCriteriaId": "D3DBBFE9-835C-4411-8492-6006E74BAC65",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:cisco:nexus_3132q-x:-:*:*:*:*:*:*:*",
"matchCriteriaId": "C97C29EE-9426-4BBE-8D84-AB5FF748703D",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:cisco:nexus_3132q-xl:-:*:*:*:*:*:*:*",
"matchCriteriaId": "8F43B770-D96C-44EA-BC12-9F39FC4317B9",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:cisco:nexus_3164q:-:*:*:*:*:*:*:*",
"matchCriteriaId": "FA782EB3-E8E6-4DCF-B39C-B3CBD46E4384",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:cisco:nexus_3172pq:-:*:*:*:*:*:*:*",
"matchCriteriaId": "CED628B5-97A8-4B26-AA40-BEC854982157",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:cisco:nexus_3172pq-xl:-:*:*:*:*:*:*:*",
"matchCriteriaId": "7BB9DD73-E31D-4921-A6D6-E14E04703588",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:cisco:nexus_3172tq:-:*:*:*:*:*:*:*",
"matchCriteriaId": "4532F513-0543-4960-9877-01F23CA7BA1B",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:cisco:nexus_3172tq-32t:-:*:*:*:*:*:*:*",
"matchCriteriaId": "0B43502B-FD53-465A-B60F-6A359C6ACD99",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:cisco:nexus_3232c:-:*:*:*:*:*:*:*",
"matchCriteriaId": "652A2849-668D-4156-88FB-C19844A59F33",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:cisco:nexus_3264c-e:-:*:*:*:*:*:*:*",
"matchCriteriaId": "24FBE87B-8A4F-43A8-98A3-4A7D9C630937",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:cisco:nexus_3264q:-:*:*:*:*:*:*:*",
"matchCriteriaId": "6ACD09AC-8B28-4ACB-967B-AB3D450BC137",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:cisco:nexus_34180yc:-:*:*:*:*:*:*:*",
"matchCriteriaId": "DC7286A7-780F-4A45-940A-4AD5C9D0F201",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:cisco:nexus_3524-x:-:*:*:*:*:*:*:*",
"matchCriteriaId": "10F80A72-AD54-4699-B8AE-82715F0B58E2",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:cisco:nexus_3524-xl:-:*:*:*:*:*:*:*",
"matchCriteriaId": "9354B6A2-D7D6-442E-BF4C-FE8A336D9E94",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:cisco:nexus_3548:-:*:*:*:*:*:*:*",
"matchCriteriaId": "088C0323-683A-44F5-8D42-FF6EC85D080E",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:cisco:nexus_3548-x:-:*:*:*:*:*:*:*",
"matchCriteriaId": "74CB4002-7636-4382-B33E-FBA060A13C34",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:cisco:nexus_3548-xl:-:*:*:*:*:*:*:*",
"matchCriteriaId": "10CEBF73-3EE0-459A-86C5-F8F6243FE27C",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:cisco:nexus_3636c-r:-:*:*:*:*:*:*:*",
"matchCriteriaId": "57572E4A-78D5-4D1A-938B-F05F01759612",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:cisco:nexus_c36180yc-r:-:*:*:*:*:*:*:*",
"matchCriteriaId": "0C9D4C48-4D01-4761-B2D8-F16E90F78560",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:cisco:nx-os:*:*:*:*:*:*:*:*",
"matchCriteriaId": "D75479AD-9847-497C-9438-AA82D91B6F71",
"versionEndExcluding": "7.3\\(3\\)n1\\(1\\)",
"versionStartIncluding": "6.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:cisco:nexus_6001p:-:*:*:*:*:*:*:*",
"matchCriteriaId": "51EAD169-9036-496E-B740-45D79546F6D6",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:cisco:nexus_6001t:-:*:*:*:*:*:*:*",
"matchCriteriaId": "0E01F0DE-EA8A-451F-BADF-1A7A48B0C633",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:cisco:nx-os:7.0:*:*:*:*:*:*:*",
"matchCriteriaId": "02DD5791-E4D3-475C-84B0-E642ACFC5EB6",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:cisco:nexus_9500:-:*:*:*:*:*:*:*",
"matchCriteriaId": "63BE0266-1C00-4D6A-AD96-7F82532ABAA7",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability in the Border Gateway Protocol (BGP) implementation of Cisco NX-OS Software could allow an unauthenticated, remote attacker to cause a denial of service (DoS) condition due to the device unexpectedly reloading. The vulnerability is due to incomplete input validation of the BGP update messages. An attacker could exploit this vulnerability by sending a crafted BGP update message to the targeted device. An exploit could allow the attacker to cause the switch to reload unexpectedly. The Cisco implementation of the BGP protocol only accepts incoming BGP traffic from explicitly defined peers. To exploit this vulnerability, an attacker must be able to send the malicious packets over a TCP connection that appears to come from a trusted BGP peer or inject malformed messages into the victim\u0027s BGP network. This would require obtaining information about the BGP peers in the affected system\u0027s trusted network. The vulnerability may be triggered when the router receives a malformed BGP message from a peer on an existing BGP session. At least one BGP neighbor session must be established for a router to be vulnerable. This vulnerability affects Nexus 2000 Series Switches, Nexus 3000 Series Switches, Nexus 3500 Platform Switches, Nexus 3600 Platform Switches, Nexus 5500 Platform Switches, Nexus 5600 Platform Switches, Nexus 6000 Series Switches, Nexus 7000 Series Switches, Nexus 7700 Series Switches, Nexus 9000 Series Fabric Switches in Application Centric Infrastructure (ACI) mode, Nexus 9000 Series Switches in standalone NX-OS mode, Nexus 9500 R-Series Line Cards and Fabric Modules. Cisco Bug IDs: CSCve79599, CSCve87784, CSCve91371, CSCve91387."
},
{
"lang": "es",
"value": "Una vulnerabilidad en la implementaci\u00f3n BGP (Border Gateway Protocol) en el software Cisco NX-OS podr\u00eda permitir que un atacante remoto sin autenticar provoque una denegaci\u00f3n de servicio (DoS) debido a que el dispositivo se recarga inesperadamente. Esta vulnerabilidad se debe a la validaci\u00f3n de entrada incompleta de los mensajes de actualizaci\u00f3n de BGP. Un atacante podr\u00eda explotar esta vulnerabilidad mediante el env\u00edo de un mensaje de actualizaci\u00f3n de BGP manipulado al dispositivo objetivo. Su explotaci\u00f3n podr\u00eda permitir que el atacante provoque el reinicio inesperado del switch. La implementaci\u00f3n de Cisco del protocolo BGP solo acepta el tr\u00e1fico BGP entrante desde peers definidos de forma expl\u00edcita. Para explotar esta vulnerabilidad, un atacante debe ser capaz de enviar paquetes maliciosos por una conexi\u00f3n TCP que parece provenir de un peer BGP de confianza o inyectar mensajes mal formados en la red BGP de la v\u00edctima. Esto requerir\u00eda la obtenci\u00f3n de informaci\u00f3n sobre los peers BGP en la red de confianza del sistema afectado. La vulnerabilidad podr\u00eda desencadenarse cuando el router recibe un mensaje BGP mal formado desde un peer o una sesi\u00f3n BGP existente. Debe establecerse, por lo menos, una sesi\u00f3n BGP vecina para que un router sea vulnerable. La vulnerabilidad afecta a Nexus 2000 Series Switches, Nexus 3000 Series Switches, Nexus 3500 Platform Switches, Nexus 3600 Platform Switches, Nexus 5500 Platform Switches, Nexus 5600 Platform Switches, Nexus 6000 Series Switches, Nexus 7000 Series Switches, Nexus 7700 Series Switches, Nexus 9000 Series Fabric Switches en modo Application Centric Infrastructure (ACI), Nexus 9000 Series Switches en modo NX-OS independiente y los m\u00f3dulos Line Cards y Fabric de Nexus 9500 R-Series. Cisco Bug IDs: CSCve79599, CSCve87784, CSCve91371, CSCve91387."
}
],
"id": "CVE-2018-0295",
"lastModified": "2024-11-21T03:37:55.090",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "HIGH",
"cvssData": {
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"availabilityImpact": "COMPLETE",
"baseScore": 7.8,
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C",
"version": "2.0"
},
"exploitabilityScore": 10.0,
"impactScore": 6.9,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": false
}
],
"cvssMetricV30": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.0"
},
"exploitabilityScore": 3.9,
"impactScore": 3.6,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2018-06-20T21:29:00.437",
"references": [
{
"source": "psirt@cisco.com",
"tags": [
"Third Party Advisory",
"VDB Entry"
],
"url": "http://www.securitytracker.com/id/1041169"
},
{
"source": "psirt@cisco.com",
"tags": [
"Vendor Advisory"
],
"url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20180620-nxosbgp"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory",
"VDB Entry"
],
"url": "http://www.securitytracker.com/id/1041169"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Vendor Advisory"
],
"url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20180620-nxosbgp"
}
],
"sourceIdentifier": "psirt@cisco.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-20"
}
],
"source": "psirt@cisco.com",
"type": "Secondary"
},
{
"description": [
{
"lang": "en",
"value": "CWE-20"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
},
"vulnrichment": {
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T03:21:15.489Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20180620-nxosbgp"
},
{
"name": "1041169",
"tags": [
"vdb-entry",
"x_refsource_SECTRACK",
"x_transferred"
],
"url": "http://www.securitytracker.com/id/1041169"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2018-0295",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-11-29T14:43:43.333193Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-11-29T14:44:30.027Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "Cisco NX-OS unknown",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "Cisco NX-OS unknown"
}
]
}
],
"datePublic": "2018-06-20T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "A vulnerability in the Border Gateway Protocol (BGP) implementation of Cisco NX-OS Software could allow an unauthenticated, remote attacker to cause a denial of service (DoS) condition due to the device unexpectedly reloading. The vulnerability is due to incomplete input validation of the BGP update messages. An attacker could exploit this vulnerability by sending a crafted BGP update message to the targeted device. An exploit could allow the attacker to cause the switch to reload unexpectedly. The Cisco implementation of the BGP protocol only accepts incoming BGP traffic from explicitly defined peers. To exploit this vulnerability, an attacker must be able to send the malicious packets over a TCP connection that appears to come from a trusted BGP peer or inject malformed messages into the victim\u0027s BGP network. This would require obtaining information about the BGP peers in the affected system\u0027s trusted network. The vulnerability may be triggered when the router receives a malformed BGP message from a peer on an existing BGP session. At least one BGP neighbor session must be established for a router to be vulnerable. This vulnerability affects Nexus 2000 Series Switches, Nexus 3000 Series Switches, Nexus 3500 Platform Switches, Nexus 3600 Platform Switches, Nexus 5500 Platform Switches, Nexus 5600 Platform Switches, Nexus 6000 Series Switches, Nexus 7000 Series Switches, Nexus 7700 Series Switches, Nexus 9000 Series Fabric Switches in Application Centric Infrastructure (ACI) mode, Nexus 9000 Series Switches in standalone NX-OS mode, Nexus 9500 R-Series Line Cards and Fabric Modules. Cisco Bug IDs: CSCve79599, CSCve87784, CSCve91371, CSCve91387."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-20",
"description": "CWE-20",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2018-06-23T09:57:01.000Z",
"orgId": "d1c1063e-7a18-46af-9102-31f8928bc633",
"shortName": "cisco"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20180620-nxosbgp"
},
{
"name": "1041169",
"tags": [
"vdb-entry",
"x_refsource_SECTRACK"
],
"url": "http://www.securitytracker.com/id/1041169"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "psirt@cisco.com",
"ID": "CVE-2018-0295",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Cisco NX-OS unknown",
"version": {
"version_data": [
{
"version_value": "Cisco NX-OS unknown"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A vulnerability in the Border Gateway Protocol (BGP) implementation of Cisco NX-OS Software could allow an unauthenticated, remote attacker to cause a denial of service (DoS) condition due to the device unexpectedly reloading. The vulnerability is due to incomplete input validation of the BGP update messages. An attacker could exploit this vulnerability by sending a crafted BGP update message to the targeted device. An exploit could allow the attacker to cause the switch to reload unexpectedly. The Cisco implementation of the BGP protocol only accepts incoming BGP traffic from explicitly defined peers. To exploit this vulnerability, an attacker must be able to send the malicious packets over a TCP connection that appears to come from a trusted BGP peer or inject malformed messages into the victim\u0027s BGP network. This would require obtaining information about the BGP peers in the affected system\u0027s trusted network. The vulnerability may be triggered when the router receives a malformed BGP message from a peer on an existing BGP session. At least one BGP neighbor session must be established for a router to be vulnerable. This vulnerability affects Nexus 2000 Series Switches, Nexus 3000 Series Switches, Nexus 3500 Platform Switches, Nexus 3600 Platform Switches, Nexus 5500 Platform Switches, Nexus 5600 Platform Switches, Nexus 6000 Series Switches, Nexus 7000 Series Switches, Nexus 7700 Series Switches, Nexus 9000 Series Fabric Switches in Application Centric Infrastructure (ACI) mode, Nexus 9000 Series Switches in standalone NX-OS mode, Nexus 9500 R-Series Line Cards and Fabric Modules. Cisco Bug IDs: CSCve79599, CSCve87784, CSCve91371, CSCve91387."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-20"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20180620-nxosbgp",
"refsource": "CONFIRM",
"url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20180620-nxosbgp"
},
{
"name": "1041169",
"refsource": "SECTRACK",
"url": "http://www.securitytracker.com/id/1041169"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "d1c1063e-7a18-46af-9102-31f8928bc633",
"assignerShortName": "cisco",
"cveId": "CVE-2018-0295",
"datePublished": "2018-06-20T21:00:00.000Z",
"dateReserved": "2017-11-27T00:00:00.000Z",
"dateUpdated": "2024-11-29T15:02:09.803Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
}
}
Drag nodes to arrange them. Double-click a related vulnerability to open it, or a source to visit its link. The Physics button on the left tunes the layout and the simulation; the legend at the bottom left hides or shows nodes by kind and by sighting type.
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Vulnerability timeline
Sightings and recorded dates, grouped by day · UTC
How durations are calculated
Following the VTEM framework (Black Hat USA 2015), time to patch starts when the vendor or a coordinator was informed, total time to patch at discovery, and disclosure to patch at public disclosure; vendor response time runs from the report to its acknowledgement. Time to exploit and time unpatched start at the earliest discovery or report, falling back to public disclosure. Unpatched time ends at the first recorded patch, or the calculation time when no patch is recorded. Exploitation to patch shows the interval between those two events; a published proof of concept is a public exploit, not exploitation.
Each result shows its source dates. A negative interval means the end event came first; when date-only inputs leave the order open, the result says so. Date-only inputs are approximate. The earliest evidence wins: KEV report dates and sightings are labelled as such. Records describing another vulnerability are listed but never calculated from, and a PoC alone does not establish exploitation. Missing patch evidence does not prove that no patch exists. Filters below change the event list only.
Loading timeline…
The approach is described in our paper Mapping CVEs to MITRE ATT&CK Techniques: A Curated Gold-Set Classifier and the Limits of LLM-Assisted Label Expansion.
Browse all ATT&CK techniques and the vulnerabilities related to each.
Related by attack behaviour
Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.