CVE-2017-3765 (GCVE-0-2017-3765)
Vulnerability from cvelistv5 – Published: 2018-01-10 18:00 – Updated: 2024-09-17 01:10
VLAI
EPSS
VEX
Summary
In Enterprise Networking Operating System (ENOS) in Lenovo and IBM RackSwitch and BladeCenter products, an authentication bypass known as "HP Backdoor" was discovered during a Lenovo security audit in the serial console, Telnet, SSH, and Web interfaces. This bypass mechanism can be accessed when performing local authentication under specific circumstances. If exploited, admin-level access to the switch is granted.
Severity
7.0 (High)
CWE
- Authentication Bypass
Assigner
References
2 references
| URL | Tags |
|---|---|
| https://support.lenovo.com/us/en/product_security… | x_refsource_CONFIRM |
| http://www.securitytracker.com/id/1040296 | vdb-entryx_refsource_SECTRACK |
Impacted products
1 product
| Vendor | Product | Version | CPE status | |
|---|---|---|---|---|
| Lenovo Group Ltd. | Enterprise Network Operating System affecting Lenovo and IBM RackSwitch and BladeCenter Products |
Affected:
Earlier than
|
guessed |
Date Public
2018-01-09 00:00
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T14:39:41.059Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://support.lenovo.com/us/en/product_security/LEN-16095"
},
{
"name": "1040296",
"tags": [
"vdb-entry",
"x_refsource_SECTRACK",
"x_transferred"
],
"url": "http://www.securitytracker.com/id/1040296"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Enterprise Network Operating System affecting Lenovo and IBM RackSwitch and BladeCenter Products",
"vendor": "Lenovo Group Ltd.",
"versions": [
{
"status": "affected",
"version": "Earlier than"
}
]
}
],
"datePublic": "2018-01-09T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "In Enterprise Networking Operating System (ENOS) in Lenovo and IBM RackSwitch and BladeCenter products, an authentication bypass known as \"HP Backdoor\" was discovered during a Lenovo security audit in the serial console, Telnet, SSH, and Web interfaces. This bypass mechanism can be accessed when performing local authentication under specific circumstances. If exploited, admin-level access to the switch is granted."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "Authentication Bypass",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2018-01-31T10:57:01.000Z",
"orgId": "da227ddf-6e25-4b41-b023-0f976dcaca4b",
"shortName": "lenovo"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://support.lenovo.com/us/en/product_security/LEN-16095"
},
{
"name": "1040296",
"tags": [
"vdb-entry",
"x_refsource_SECTRACK"
],
"url": "http://www.securitytracker.com/id/1040296"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "psirt@lenovo.com",
"DATE_PUBLIC": "2018-01-09T00:00:00",
"ID": "CVE-2017-3765",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Enterprise Network Operating System affecting Lenovo and IBM RackSwitch and BladeCenter Products",
"version": {
"version_data": [
{
"version_value": "Earlier than"
}
]
}
}
]
},
"vendor_name": "Lenovo Group Ltd."
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "In Enterprise Networking Operating System (ENOS) in Lenovo and IBM RackSwitch and BladeCenter products, an authentication bypass known as \"HP Backdoor\" was discovered during a Lenovo security audit in the serial console, Telnet, SSH, and Web interfaces. This bypass mechanism can be accessed when performing local authentication under specific circumstances. If exploited, admin-level access to the switch is granted."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "Authentication Bypass"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://support.lenovo.com/us/en/product_security/LEN-16095",
"refsource": "CONFIRM",
"url": "https://support.lenovo.com/us/en/product_security/LEN-16095"
},
{
"name": "1040296",
"refsource": "SECTRACK",
"url": "http://www.securitytracker.com/id/1040296"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "da227ddf-6e25-4b41-b023-0f976dcaca4b",
"assignerShortName": "lenovo",
"cveId": "CVE-2017-3765",
"datePublished": "2018-01-10T18:00:00.000Z",
"dateReserved": "2016-12-16T00:00:00.000Z",
"dateUpdated": "2024-09-17T01:10:39.100Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"epss": {
"cve": "CVE-2017-3765",
"date": "2026-11-06",
"epss": "0.00269",
"percentile": "0.19097"
},
"nvd": {
"cve": {
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:lenovo:enterprise_network_operating_system:*:*:*:*:*:*:*:*",
"matchCriteriaId": "0B6FA22A-0EB1-4062-9E3E-5BCE507AB21A",
"versionEndExcluding": "8.4.6.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:lenovo:flex_system_fabric_cn4093_10gb_converged_scalable_switch:-:*:*:*:*:*:*:*",
"matchCriteriaId": "CD14D4A6-68F5-4B92-9D8D-4DC8496A39ED",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:lenovo:flex_system_fabric_en4093r_10gb_scalable_switch:-:*:*:*:*:*:*:*",
"matchCriteriaId": "C5195330-F644-4E3E-83B2-8890DB80734C",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:lenovo:flex_system_fabric_si4093_10gb_system_interconnect_module:-:*:*:*:*:*:*:*",
"matchCriteriaId": "8554C433-4DDA-4A39-B01E-441A4692FA92",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:lenovo:flex_system_si4091_system_interconnect_module:-:*:*:*:*:*:*:*",
"matchCriteriaId": "140910FE-22A3-47C2-9FC7-E3093C0761A3",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:lenovo:rackswitch_g7028:-:*:*:*:*:*:*:*",
"matchCriteriaId": "C8D163A9-605F-435C-870E-E28B386686F1",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:lenovo:rackswitch_g7052:-:*:*:*:*:*:*:*",
"matchCriteriaId": "CC6C0D57-16DE-470F-B707-F7A704BFA36C",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:lenovo:rackswitch_g8052:-:*:*:*:*:*:*:*",
"matchCriteriaId": "137C0A4F-A13B-4BFA-A323-3B8665C9EFA0",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:lenovo:rackswitch_g8124e:-:*:*:*:*:*:*:*",
"matchCriteriaId": "FD40C661-A1B6-4CA5-86AD-6901AFB65C8B",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:lenovo:rackswitch_g8264:-:*:*:*:*:*:*:*",
"matchCriteriaId": "58E04854-B986-400B-BB67-E2821C96E220",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:lenovo:rackswitch_g8264cs:-:*:*:*:*:*:*:*",
"matchCriteriaId": "5FD9C184-F542-4111-9617-C39BA1D75861",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:lenovo:rackswitch_g8272:-:*:*:*:*:*:*:*",
"matchCriteriaId": "DB8AF1A2-AC14-46E3-BCF1-41C48F0D45BA",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:lenovo:rackswitch_g8296:-:*:*:*:*:*:*:*",
"matchCriteriaId": "B3C14274-E752-4FCF-96DE-8EE02D07BB48",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:lenovo:rackswitch_g8332:-:*:*:*:*:*:*:*",
"matchCriteriaId": "B8D47782-1C9C-4C89-852C-637E09CB9E20",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:lenovo:enterprise_network_operating_system:*:*:*:*:*:*:*:*",
"matchCriteriaId": "0B6FA22A-0EB1-4062-9E3E-5BCE507AB21A",
"versionEndExcluding": "8.4.6.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:ibm:1g_l2-7_slb_switch_for_bladecenter:-:*:*:*:*:*:*:*",
"matchCriteriaId": "554F09B6-E3E9-4614-8B09-83B3D9CB2DAC",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:ibm:bladecenter_1\\:10g_uplink_ethernet_switch_module:-:*:*:*:*:*:*:*",
"matchCriteriaId": "C516EA8F-AB20-41B0-8C73-320DC0E0D967",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:ibm:bladecenter_layer_2\\/3_copper_ethernet_switch_module:-:*:*:*:*:*:*:*",
"matchCriteriaId": "55112B25-5F9A-46D3-85E2-9BB3F3A38A04",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:ibm:bladecenter_virtual_fabric_10gb_switch_module:-:*:*:*:*:*:*:*",
"matchCriteriaId": "A248A49B-838D-481E-903D-B184E0550522",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:ibm:flex_system_en2092_1gb_ethernet_scalable_switch:-:*:*:*:*:*:*:*",
"matchCriteriaId": "A2FFDBDC-BC5B-4945-998B-EF7A84D05442",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:ibm:flex_system_fabric_cn4093_10gb_converged_scalable_switch:-:*:*:*:*:*:*:*",
"matchCriteriaId": "F62317AD-325B-43EE-BBEA-7577FFA0377B",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:ibm:flex_system_fabric_en4093\\/en4093r_10gb_scalable_switch:-:*:*:*:*:*:*:*",
"matchCriteriaId": "E6132020-30E0-4D5F-913B-71EB74AFDC94",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:ibm:flex_system_fabric_si4093_10gb_system_interconnect_module:-:*:*:*:*:*:*:*",
"matchCriteriaId": "75E66FEC-BDD9-4B51-8DCB-76377C92EDBD",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:ibm:rackswitch_g8052:-:*:*:*:*:*:*:*",
"matchCriteriaId": "7ADA45C1-84D8-44E4-8D53-D9E0A82E5890",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:ibm:rackswitch_g8124:-:*:*:*:*:*:*:*",
"matchCriteriaId": "96901ABF-A65F-4A07-892E-445C6AE170A1",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:ibm:rackswitch_g8124e:-:*:*:*:*:*:*:*",
"matchCriteriaId": "3DAD3932-2C0A-4F08-91E0-8C6744570A80",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:ibm:rackswitch_g8264:-:*:*:*:*:*:*:*",
"matchCriteriaId": "5F4D033F-5B82-4C4A-BD12-D6AF3D9986AD",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:ibm:rackswitch_g8264cs:-:*:*:*:*:*:*:*",
"matchCriteriaId": "11929E3F-DE7A-44AD-9111-A573C0EB9AD5",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:ibm:rackswitch_g8264t:-:*:*:*:*:*:*:*",
"matchCriteriaId": "19BC18A3-A42E-4231-8F1C-175A5F17DDD4",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:ibm:rackswitch_g8316:-:*:*:*:*:*:*:*",
"matchCriteriaId": "B26833BE-762B-4124-A3E1-CCE50E80D35C",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:ibm:rackswitch_g8332:-:*:*:*:*:*:*:*",
"matchCriteriaId": "C35153A7-35EF-4E95-B93B-FF38E7160336",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "In Enterprise Networking Operating System (ENOS) in Lenovo and IBM RackSwitch and BladeCenter products, an authentication bypass known as \"HP Backdoor\" was discovered during a Lenovo security audit in the serial console, Telnet, SSH, and Web interfaces. This bypass mechanism can be accessed when performing local authentication under specific circumstances. If exploited, admin-level access to the switch is granted."
},
{
"lang": "es",
"value": "En Enterprise Networking Operating System (ENOS) en productos Lenovo, IBM RackSwitch y BladeCenter, se descubri\u00f3 una omisi\u00f3n de autenticaci\u00f3n conocida como \"HP Backdoor\" durante una auditar\u00eda de seguridad de Lenovo en las interfaces de la consola de serie, Telnet, SSH y Web. Se puede acceder al mecanismo de omisi\u00f3n cuando se realiza una autenticaci\u00f3n local bajo ciertas circunstancias. Si se explota, se concede el acceso a nivel de administrador al switch."
}
],
"id": "CVE-2017-3765",
"lastModified": "2024-11-21T03:26:05.847",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "MEDIUM",
"cvssData": {
"accessComplexity": "HIGH",
"accessVector": "LOCAL",
"authentication": "NONE",
"availabilityImpact": "COMPLETE",
"baseScore": 6.2,
"confidentialityImpact": "COMPLETE",
"integrityImpact": "COMPLETE",
"vectorString": "AV:L/AC:H/Au:N/C:C/I:C/A:C",
"version": "2.0"
},
"exploitabilityScore": 1.9,
"impactScore": 10.0,
"obtainAllPrivilege": true,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": false
}
],
"cvssMetricV30": [
{
"cvssData": {
"attackComplexity": "HIGH",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.0,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:L/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
},
"exploitabilityScore": 1.0,
"impactScore": 5.9,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2018-01-10T18:29:01.383",
"references": [
{
"source": "psirt@lenovo.com",
"tags": [
"Third Party Advisory"
],
"url": "http://www.securitytracker.com/id/1040296"
},
{
"source": "psirt@lenovo.com",
"tags": [
"Mitigation",
"Patch",
"Vendor Advisory"
],
"url": "https://support.lenovo.com/us/en/product_security/LEN-16095"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory"
],
"url": "http://www.securitytracker.com/id/1040296"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Mitigation",
"Patch",
"Vendor Advisory"
],
"url": "https://support.lenovo.com/us/en/product_security/LEN-16095"
}
],
"sourceIdentifier": "psirt@lenovo.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-287"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
}
}
}
Loading…
Loading…
Drag nodes to arrange them. Double-click a related vulnerability to open it, or a source to visit its link. The Physics button on the left tunes the layout and the simulation; the legend at the bottom left hides or shows nodes by kind and by sighting type.
Experimental. This forecast is provided for visualization only and may change without notice. Do not use it for operational decisions.
Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Vulnerability timeline
Sightings and recorded dates, grouped by day · UTC
Loading timeline…
Loading…
Loading…
The MITRE ATT&CK techniques below are AI-generated suggestions, inferred from the description of the
vulnerability by the CIRCL/vulnerability-attack-technique-classification-roberta-base
model, served locally by ML-Gateway.
They have not been verified by an analyst and are provided for guidance only.
The approach is described in our paper Mapping CVEs to MITRE ATT&CK Techniques: A Curated Gold-Set Classifier and the Limits of LLM-Assisted Label Expansion.
Browse all ATT&CK techniques and the vulnerabilities related to each.
The approach is described in our paper Mapping CVEs to MITRE ATT&CK Techniques: A Curated Gold-Set Classifier and the Limits of LLM-Assisted Label Expansion.
Browse all ATT&CK techniques and the vulnerabilities related to each.
Loading…
Related by attack behaviour
Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.