CVE-2017-15008 (GCVE-0-2017-15008)

Vulnerability from cvelistv5 – Published: 2017-10-03 16:00 – Updated: 2024-09-17 02:12
VLAI
Summary
PRTG Network Monitor version 17.3.33.2830 is vulnerable to stored Cross-Site Scripting on all sensor titles, related to incorrect error handling for a %00 in the SRC attribute of an IMG element.
CWE
  • n/a
References
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T19:42:22.314Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://medium.com/stolabs/security-issue-on-prtg-network-manager-ada65b45d37b"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "PRTG Network Monitor version 17.3.33.2830 is vulnerable to stored Cross-Site Scripting on all sensor titles, related to incorrect error handling for a %00 in the SRC attribute of an IMG element."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2017-10-03T16:00:00.000Z",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://medium.com/stolabs/security-issue-on-prtg-network-manager-ada65b45d37b"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2017-15008",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "PRTG Network Monitor version 17.3.33.2830 is vulnerable to stored Cross-Site Scripting on all sensor titles, related to incorrect error handling for a %00 in the SRC attribute of an IMG element."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://medium.com/stolabs/security-issue-on-prtg-network-manager-ada65b45d37b",
              "refsource": "MISC",
              "url": "https://medium.com/stolabs/security-issue-on-prtg-network-manager-ada65b45d37b"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2017-15008",
    "datePublished": "2017-10-03T16:00:00.000Z",
    "dateReserved": "2017-10-03T00:00:00.000Z",
    "dateUpdated": "2024-09-17T02:12:17.533Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "epss": {
      "cve": "CVE-2017-15008",
      "date": "2026-09-26",
      "epss": "0.00529",
      "percentile": "0.42439"
    },
    "nvd": {
      "cve": {
        "configurations": [
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:a:paessler:prtg_network_monitor:17.3.33.2830:*:*:*:*:*:*:*",
                    "matchCriteriaId": "50563838-FE5C-4B0F-BBFE-6D6D8072077D",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ]
          }
        ],
        "cveTags": [],
        "descriptions": [
          {
            "lang": "en",
            "value": "PRTG Network Monitor version 17.3.33.2830 is vulnerable to stored Cross-Site Scripting on all sensor titles, related to incorrect error handling for a %00 in the SRC attribute of an IMG element."
          },
          {
            "lang": "es",
            "value": "La versi\u00f3n 17.3.33.2830 de PRTG Network Monitor es vulnerable a Cross-Site Scripting (XSS) persistente en todos los t\u00edtulos de sensores. Esto se relaciona con una mala gesti\u00f3n de errores para un %00 en el atributo SRC de un elemento IMG."
          }
        ],
        "id": "CVE-2017-15008",
        "lastModified": "2026-05-13T00:24:29.033",
        "metrics": {
          "cvssMetricV2": [
            {
              "acInsufInfo": false,
              "baseSeverity": "LOW",
              "cvssData": {
                "accessComplexity": "MEDIUM",
                "accessVector": "NETWORK",
                "authentication": "SINGLE",
                "availabilityImpact": "NONE",
                "baseScore": 3.5,
                "confidentialityImpact": "NONE",
                "integrityImpact": "PARTIAL",
                "vectorString": "AV:N/AC:M/Au:S/C:N/I:P/A:N",
                "version": "2.0"
              },
              "exploitabilityScore": 6.8,
              "impactScore": 2.9,
              "obtainAllPrivilege": false,
              "obtainOtherPrivilege": false,
              "obtainUserPrivilege": false,
              "source": "nvd@nist.gov",
              "type": "Primary",
              "userInteractionRequired": true
            }
          ],
          "cvssMetricV30": [
            {
              "cvssData": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "NONE",
                "baseScore": 4.8,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "LOW",
                "integrityImpact": "LOW",
                "privilegesRequired": "HIGH",
                "scope": "CHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:N",
                "version": "3.0"
              },
              "exploitabilityScore": 1.7,
              "impactScore": 2.7,
              "source": "nvd@nist.gov",
              "type": "Primary"
            }
          ]
        },
        "published": "2017-10-04T01:29:03.340",
        "references": [
          {
            "source": "cve@mitre.org",
            "tags": [
              "Exploit",
              "Technical Description",
              "Third Party Advisory"
            ],
            "url": "https://medium.com/stolabs/security-issue-on-prtg-network-manager-ada65b45d37b"
          },
          {
            "source": "af854a3a-2127-422b-91ae-364da2661108",
            "tags": [
              "Exploit",
              "Technical Description",
              "Third Party Advisory"
            ],
            "url": "https://medium.com/stolabs/security-issue-on-prtg-network-manager-ada65b45d37b"
          }
        ],
        "sourceIdentifier": "cve@mitre.org",
        "vulnStatus": "Modified",
        "weaknesses": [
          {
            "description": [
              {
                "lang": "en",
                "value": "CWE-79"
              }
            ],
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ]
      }
    }
  }
}



Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.

Loading…

Loading…

Loading…

Related by attack behaviour

Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.


Loading…