Action not permitted
Modal body text goes here.
Modal Title
Modal Body
CVE-2012-1817 (GCVE-0-2012-1817)
Vulnerability from cvelistv5 – Published: 2012-06-08 18:00 – Updated: 2024-08-06 19:08- n/a
| URL | Tags |
|---|---|
| http://secunia.com/advisories/49210 | third-party-advisoryx_refsource_SECUNIA |
| http://www.securityfocus.com/bid/53591 | vdb-entryx_refsource_BID |
| http://osvdb.org/82013 | vdb-entryx_refsource_OSVDB |
| http://www.us-cert.gov/control_systems/pdf/ICSA-1… | x_refsource_MISC |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-06T19:08:38.471Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "49210",
"tags": [
"third-party-advisory",
"x_refsource_SECUNIA",
"x_transferred"
],
"url": "http://secunia.com/advisories/49210"
},
{
"name": "53591",
"tags": [
"vdb-entry",
"x_refsource_BID",
"x_transferred"
],
"url": "http://www.securityfocus.com/bid/53591"
},
{
"name": "82013",
"tags": [
"vdb-entry",
"x_refsource_OSVDB",
"x_transferred"
],
"url": "http://osvdb.org/82013"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-138-01.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"datePublic": "2012-05-30T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "Buffer overflow in Emerson DeltaV and DeltaV Workstations 9.3.1, 10.3.1, 11.3, and 11.3.1 and DeltaV ProEssentials Scientific Graph 5.0.0.6 allows user-assisted remote attackers to execute arbitrary code or cause a denial of service (daemon crash) via an invalid field in a project file."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2012-09-29T09:00:00.000Z",
"orgId": "37e5125f-f79b-445b-8fad-9564f167944b",
"shortName": "certcc"
},
"references": [
{
"name": "49210",
"tags": [
"third-party-advisory",
"x_refsource_SECUNIA"
],
"url": "http://secunia.com/advisories/49210"
},
{
"name": "53591",
"tags": [
"vdb-entry",
"x_refsource_BID"
],
"url": "http://www.securityfocus.com/bid/53591"
},
{
"name": "82013",
"tags": [
"vdb-entry",
"x_refsource_OSVDB"
],
"url": "http://osvdb.org/82013"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-138-01.pdf"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cert@cert.org",
"ID": "CVE-2012-1817",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Buffer overflow in Emerson DeltaV and DeltaV Workstations 9.3.1, 10.3.1, 11.3, and 11.3.1 and DeltaV ProEssentials Scientific Graph 5.0.0.6 allows user-assisted remote attackers to execute arbitrary code or cause a denial of service (daemon crash) via an invalid field in a project file."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "49210",
"refsource": "SECUNIA",
"url": "http://secunia.com/advisories/49210"
},
{
"name": "53591",
"refsource": "BID",
"url": "http://www.securityfocus.com/bid/53591"
},
{
"name": "82013",
"refsource": "OSVDB",
"url": "http://osvdb.org/82013"
},
{
"name": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-138-01.pdf",
"refsource": "MISC",
"url": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-138-01.pdf"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "37e5125f-f79b-445b-8fad-9564f167944b",
"assignerShortName": "certcc",
"cveId": "CVE-2012-1817",
"datePublished": "2012-06-08T18:00:00.000Z",
"dateReserved": "2012-03-21T00:00:00.000Z",
"dateUpdated": "2024-08-06T19:08:38.471Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"epss": {
"cve": "CVE-2012-1817",
"date": "2026-07-01",
"epss": "0.03971",
"percentile": "0.89194"
},
"nvd": "{\"cve\":{\"id\":\"CVE-2012-1817\",\"sourceIdentifier\":\"cret@cert.org\",\"published\":\"2012-06-08T18:55:01.657\",\"lastModified\":\"2026-04-29T01:13:23.040\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"Buffer overflow in Emerson DeltaV and DeltaV Workstations 9.3.1, 10.3.1, 11.3, and 11.3.1 and DeltaV ProEssentials Scientific Graph 5.0.0.6 allows user-assisted remote attackers to execute arbitrary code or cause a denial of service (daemon crash) via an invalid field in a project file.\"},{\"lang\":\"es\",\"value\":\"Desbordamiento de b\u00fafer en Emerson DeltaV y DeltaV Workstations v9.3.1, v10.3.1, v11.3, y v11.3.1 y DeltaV ProEssentials Scientific Graph v5.0.0.6, permite a atacantes remotos provocar una denegaci\u00f3n de servicio (ca\u00edda del demonio) a trav\u00e9s de un campo inv\u00e1lido en un fichero de proyecto.\"}],\"metrics\":{\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:L/Au:N/C:P/I:P/A:P\",\"baseScore\":7.5,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"LOW\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"PARTIAL\",\"integrityImpact\":\"PARTIAL\",\"availabilityImpact\":\"PARTIAL\"},\"baseSeverity\":\"HIGH\",\"exploitabilityScore\":10.0,\"impactScore\":6.4,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-20\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:emerson:deltav:9.3.1:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"2A47A4CF-7DC2-40BF-8665-261C17A4159B\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:emerson:deltav:10.3.1:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"E005DD9A-07FB-4DE2-810B-372E62A091B6\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:emerson:deltav:11.3:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"D0123046-D89E-4FBB-9176-C04E0C65E9AB\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:emerson:deltav:11.3.1:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"943B3480-56C4-4131-BE8F-62FE035D4619\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:emerson:deltav_proessentials_scientific_graph:5.0.0.6:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"75620876-5526-451E-8284-3CB1BF16642F\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:emerson:deltav_workstation:9.3.1:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"7B41EAEE-53EC-4EF0-BB63-58772E4D6278\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:emerson:deltav_workstation:10.3.1:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"FE35A6AE-616B-4254-83B6-50726498B765\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:emerson:deltav_workstation:11.3:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"E5C9C34A-FE86-4B79-BC2F-14B7F6320A8D\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:emerson:deltav_workstation:11.3.1:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"A164A098-9568-476F-BE49-D847378A7BE9\"}]}]}],\"references\":[{\"url\":\"http://osvdb.org/82013\",\"source\":\"cret@cert.org\"},{\"url\":\"http://secunia.com/advisories/49210\",\"source\":\"cret@cert.org\"},{\"url\":\"http://www.securityfocus.com/bid/53591\",\"source\":\"cret@cert.org\"},{\"url\":\"http://www.us-cert.gov/control_systems/pdf/ICSA-12-138-01.pdf\",\"source\":\"cret@cert.org\",\"tags\":[\"US Government Resource\"]},{\"url\":\"http://osvdb.org/82013\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\"},{\"url\":\"http://secunia.com/advisories/49210\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\"},{\"url\":\"http://www.securityfocus.com/bid/53591\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\"},{\"url\":\"http://www.us-cert.gov/control_systems/pdf/ICSA-12-138-01.pdf\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"US Government Resource\"]}]}}"
}
}
FKIE_CVE-2012-1817
Vulnerability from fkie_nvd - Published: 2012-06-08 18:55 - Updated: 2026-06-16 23:40| Vendor | Product | Version | |
|---|---|---|---|
| emerson | deltav | 9.3.1 | |
| emerson | deltav | 10.3.1 | |
| emerson | deltav | 11.3 | |
| emerson | deltav | 11.3.1 | |
| emerson | deltav_proessentials_scientific_graph | 5.0.0.6 | |
| emerson | deltav_workstation | 9.3.1 | |
| emerson | deltav_workstation | 10.3.1 | |
| emerson | deltav_workstation | 11.3 | |
| emerson | deltav_workstation | 11.3.1 |
{
"affected": [
{
"affectedData": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"source": "cret@cert.org"
}
],
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:emerson:deltav:9.3.1:*:*:*:*:*:*:*",
"matchCriteriaId": "2A47A4CF-7DC2-40BF-8665-261C17A4159B",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:emerson:deltav:10.3.1:*:*:*:*:*:*:*",
"matchCriteriaId": "E005DD9A-07FB-4DE2-810B-372E62A091B6",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:emerson:deltav:11.3:*:*:*:*:*:*:*",
"matchCriteriaId": "D0123046-D89E-4FBB-9176-C04E0C65E9AB",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:emerson:deltav:11.3.1:*:*:*:*:*:*:*",
"matchCriteriaId": "943B3480-56C4-4131-BE8F-62FE035D4619",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:emerson:deltav_proessentials_scientific_graph:5.0.0.6:*:*:*:*:*:*:*",
"matchCriteriaId": "75620876-5526-451E-8284-3CB1BF16642F",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:emerson:deltav_workstation:9.3.1:*:*:*:*:*:*:*",
"matchCriteriaId": "7B41EAEE-53EC-4EF0-BB63-58772E4D6278",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:emerson:deltav_workstation:10.3.1:*:*:*:*:*:*:*",
"matchCriteriaId": "FE35A6AE-616B-4254-83B6-50726498B765",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:emerson:deltav_workstation:11.3:*:*:*:*:*:*:*",
"matchCriteriaId": "E5C9C34A-FE86-4B79-BC2F-14B7F6320A8D",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:emerson:deltav_workstation:11.3.1:*:*:*:*:*:*:*",
"matchCriteriaId": "A164A098-9568-476F-BE49-D847378A7BE9",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "Buffer overflow in Emerson DeltaV and DeltaV Workstations 9.3.1, 10.3.1, 11.3, and 11.3.1 and DeltaV ProEssentials Scientific Graph 5.0.0.6 allows user-assisted remote attackers to execute arbitrary code or cause a denial of service (daemon crash) via an invalid field in a project file."
},
{
"lang": "es",
"value": "Desbordamiento de b\u00fafer en Emerson DeltaV y DeltaV Workstations v9.3.1, v10.3.1, v11.3, y v11.3.1 y DeltaV ProEssentials Scientific Graph v5.0.0.6, permite a atacantes remotos provocar una denegaci\u00f3n de servicio (ca\u00edda del demonio) a trav\u00e9s de un campo inv\u00e1lido en un fichero de proyecto."
}
],
"id": "CVE-2012-1817",
"lastModified": "2026-06-16T23:40:21.573",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "HIGH",
"cvssData": {
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"availabilityImpact": "PARTIAL",
"baseScore": 7.5,
"confidentialityImpact": "PARTIAL",
"integrityImpact": "PARTIAL",
"vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
"version": "2.0"
},
"exploitabilityScore": 10.0,
"impactScore": 6.4,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": false
}
]
},
"published": "2012-06-08T18:55:01.657",
"references": [
{
"source": "cret@cert.org",
"url": "http://osvdb.org/82013"
},
{
"source": "cret@cert.org",
"url": "http://secunia.com/advisories/49210"
},
{
"source": "cret@cert.org",
"url": "http://www.securityfocus.com/bid/53591"
},
{
"source": "cret@cert.org",
"tags": [
"US Government Resource"
],
"url": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-138-01.pdf"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"url": "http://osvdb.org/82013"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"url": "http://secunia.com/advisories/49210"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"url": "http://www.securityfocus.com/bid/53591"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"US Government Resource"
],
"url": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-138-01.pdf"
}
],
"sourceIdentifier": "cret@cert.org",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-20"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
GHSA-5XJ2-WJ79-C4PM
Vulnerability from github – Published: 2022-05-17 05:20 – Updated: 2022-05-17 05:20Buffer overflow in Emerson DeltaV and DeltaV Workstations 9.3.1, 10.3.1, 11.3, and 11.3.1 and DeltaV ProEssentials Scientific Graph 5.0.0.6 allows user-assisted remote attackers to execute arbitrary code or cause a denial of service (daemon crash) via an invalid field in a project file.
{
"affected": [],
"aliases": [
"CVE-2012-1817"
],
"database_specific": {
"cwe_ids": [
"CWE-20"
],
"github_reviewed": false,
"github_reviewed_at": null,
"nvd_published_at": "2012-06-08T18:55:00Z",
"severity": "HIGH"
},
"details": "Buffer overflow in Emerson DeltaV and DeltaV Workstations 9.3.1, 10.3.1, 11.3, and 11.3.1 and DeltaV ProEssentials Scientific Graph 5.0.0.6 allows user-assisted remote attackers to execute arbitrary code or cause a denial of service (daemon crash) via an invalid field in a project file.",
"id": "GHSA-5xj2-wj79-c4pm",
"modified": "2022-05-17T05:20:21Z",
"published": "2022-05-17T05:20:21Z",
"references": [
{
"type": "ADVISORY",
"url": "https://nvd.nist.gov/vuln/detail/CVE-2012-1817"
},
{
"type": "WEB",
"url": "http://osvdb.org/82013"
},
{
"type": "WEB",
"url": "http://secunia.com/advisories/49210"
},
{
"type": "WEB",
"url": "http://www.securityfocus.com/bid/53591"
},
{
"type": "WEB",
"url": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-138-01.pdf"
}
],
"schema_version": "1.4.0",
"severity": []
}
GSD-2012-1817
Vulnerability from gsd - Updated: 2023-12-13 01:20{
"GSD": {
"alias": "CVE-2012-1817",
"description": "Buffer overflow in Emerson DeltaV and DeltaV Workstations 9.3.1, 10.3.1, 11.3, and 11.3.1 and DeltaV ProEssentials Scientific Graph 5.0.0.6 allows user-assisted remote attackers to execute arbitrary code or cause a denial of service (daemon crash) via an invalid field in a project file.",
"id": "GSD-2012-1817"
},
"gsd": {
"metadata": {
"exploitCode": "unknown",
"remediation": "unknown",
"reportConfidence": "confirmed",
"type": "vulnerability"
},
"osvSchema": {
"aliases": [
"CVE-2012-1817"
],
"details": "Buffer overflow in Emerson DeltaV and DeltaV Workstations 9.3.1, 10.3.1, 11.3, and 11.3.1 and DeltaV ProEssentials Scientific Graph 5.0.0.6 allows user-assisted remote attackers to execute arbitrary code or cause a denial of service (daemon crash) via an invalid field in a project file.",
"id": "GSD-2012-1817",
"modified": "2023-12-13T01:20:18.213074Z",
"schema_version": "1.4.0"
}
},
"namespaces": {
"cve.org": {
"CVE_data_meta": {
"ASSIGNER": "cert@cert.org",
"ID": "CVE-2012-1817",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Buffer overflow in Emerson DeltaV and DeltaV Workstations 9.3.1, 10.3.1, 11.3, and 11.3.1 and DeltaV ProEssentials Scientific Graph 5.0.0.6 allows user-assisted remote attackers to execute arbitrary code or cause a denial of service (daemon crash) via an invalid field in a project file."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "49210",
"refsource": "SECUNIA",
"url": "http://secunia.com/advisories/49210"
},
{
"name": "53591",
"refsource": "BID",
"url": "http://www.securityfocus.com/bid/53591"
},
{
"name": "82013",
"refsource": "OSVDB",
"url": "http://osvdb.org/82013"
},
{
"name": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-138-01.pdf",
"refsource": "MISC",
"url": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-138-01.pdf"
}
]
}
},
"nvd.nist.gov": {
"configurations": {
"CVE_data_version": "4.0",
"nodes": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:a:emerson:deltav:11.3:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:emerson:deltav_workstation:11.3:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:emerson:deltav:9.3.1:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:emerson:deltav_workstation:9.3.1:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:emerson:deltav:11.3.1:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:emerson:deltav_workstation:11.3.1:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:emerson:deltav_proessentials_scientific_graph:5.0.0.6:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:emerson:deltav_workstation:10.3.1:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:emerson:deltav:10.3.1:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
}
]
},
"cve": {
"CVE_data_meta": {
"ASSIGNER": "cert@cert.org",
"ID": "CVE-2012-1817"
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "en",
"value": "Buffer overflow in Emerson DeltaV and DeltaV Workstations 9.3.1, 10.3.1, 11.3, and 11.3.1 and DeltaV ProEssentials Scientific Graph 5.0.0.6 allows user-assisted remote attackers to execute arbitrary code or cause a denial of service (daemon crash) via an invalid field in a project file."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "en",
"value": "CWE-20"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-138-01.pdf",
"refsource": "MISC",
"tags": [
"US Government Resource"
],
"url": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-138-01.pdf"
},
{
"name": "49210",
"refsource": "SECUNIA",
"tags": [],
"url": "http://secunia.com/advisories/49210"
},
{
"name": "53591",
"refsource": "BID",
"tags": [],
"url": "http://www.securityfocus.com/bid/53591"
},
{
"name": "82013",
"refsource": "OSVDB",
"tags": [],
"url": "http://osvdb.org/82013"
}
]
}
},
"impact": {
"baseMetricV2": {
"cvssV2": {
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"availabilityImpact": "PARTIAL",
"baseScore": 7.5,
"confidentialityImpact": "PARTIAL",
"integrityImpact": "PARTIAL",
"vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
"version": "2.0"
},
"exploitabilityScore": 10.0,
"impactScore": 6.4,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"severity": "HIGH",
"userInteractionRequired": false
}
},
"lastModifiedDate": "2012-10-13T03:22Z",
"publishedDate": "2012-06-08T18:55Z"
}
}
}
ICSA-12-138-01
Vulnerability from csaf_cisa - Published: 2012-02-18 07:00 - Updated: 2025-06-17 15:45| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
Emerson DeltaV: 9.3.1|10.3.1|11.3|11.3.1
Emerson / DeltaV
|
9.3.1|10.3.1|11.3|11.3.1 |
Mitigation
Mitigation
|
|
|
Emerson DeltaV Workstations: 9.3.1|10.3.1|11.3|11.3.1
Emerson / DeltaV Workstations
|
9.3.1|10.3.1|11.3|11.3.1 |
Mitigation
Mitigation
|
|
|
Emerson DeltaV ProEssentials Scientific Graph: V5.0.0.6
Emerson / DeltaV ProEssentials Scientific Graph
|
V5.0.0.6 |
Mitigation
Mitigation
|
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
Emerson DeltaV: 9.3.1|10.3.1|11.3|11.3.1
Emerson / DeltaV
|
9.3.1|10.3.1|11.3|11.3.1 |
Mitigation
Mitigation
|
|
|
Emerson DeltaV Workstations: 9.3.1|10.3.1|11.3|11.3.1
Emerson / DeltaV Workstations
|
9.3.1|10.3.1|11.3|11.3.1 |
Mitigation
Mitigation
|
|
|
Emerson DeltaV ProEssentials Scientific Graph: V5.0.0.6
Emerson / DeltaV ProEssentials Scientific Graph
|
V5.0.0.6 |
Mitigation
Mitigation
|
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
Emerson DeltaV: 9.3.1|10.3.1|11.3|11.3.1
Emerson / DeltaV
|
9.3.1|10.3.1|11.3|11.3.1 |
Mitigation
Mitigation
|
|
|
Emerson DeltaV Workstations: 9.3.1|10.3.1|11.3|11.3.1
Emerson / DeltaV Workstations
|
9.3.1|10.3.1|11.3|11.3.1 |
Mitigation
Mitigation
|
|
|
Emerson DeltaV ProEssentials Scientific Graph: V5.0.0.6
Emerson / DeltaV ProEssentials Scientific Graph
|
V5.0.0.6 |
Mitigation
Mitigation
|
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
Emerson DeltaV: 9.3.1|10.3.1|11.3|11.3.1
Emerson / DeltaV
|
9.3.1|10.3.1|11.3|11.3.1 |
Mitigation
Mitigation
|
|
|
Emerson DeltaV Workstations: 9.3.1|10.3.1|11.3|11.3.1
Emerson / DeltaV Workstations
|
9.3.1|10.3.1|11.3|11.3.1 |
Mitigation
Mitigation
|
|
|
Emerson DeltaV ProEssentials Scientific Graph: V5.0.0.6
Emerson / DeltaV ProEssentials Scientific Graph
|
V5.0.0.6 |
Mitigation
Mitigation
|
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
Emerson DeltaV: 9.3.1|10.3.1|11.3|11.3.1
Emerson / DeltaV
|
9.3.1|10.3.1|11.3|11.3.1 |
Mitigation
Mitigation
|
|
|
Emerson DeltaV Workstations: 9.3.1|10.3.1|11.3|11.3.1
Emerson / DeltaV Workstations
|
9.3.1|10.3.1|11.3|11.3.1 |
Mitigation
Mitigation
|
|
|
Emerson DeltaV ProEssentials Scientific Graph: V5.0.0.6
Emerson / DeltaV ProEssentials Scientific Graph
|
V5.0.0.6 |
Mitigation
Mitigation
|
{
"document": {
"category": "csaf_security_advisory",
"csaf_version": "2.0",
"distribution": {
"text": "Disclosure is not limited",
"tlp": {
"label": "WHITE",
"url": "https://us-cert.cisa.gov/tlp/"
}
},
"lang": "en-US",
"notes": [
{
"category": "legal_disclaimer",
"text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.",
"title": "Legal Notice"
},
{
"category": "general",
"text": "This CSAF advisory was extracted from unstructured data and may contain inaccuracies. If you notice any errors, please reach out to the designated contact at CISA CSAF: central@cisa.dhs.gov",
"title": "CISA Disclaimer"
},
{
"category": "general",
"text": "CISA recommends users take defensive measures to minimize the risk of exploitation.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Locate control system networks and remote devices behind firewalls and isolating them from business networks.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs). Recognize VPNs may have vulnerabilities, should be updated to the most recent version available, and are only as secure as the connected devices.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA also recommends users take the following measures to protect themselves from social engineering attacks: Do not click web links or open attachments in unsolicited email messages. Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams. Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks.",
"title": "Recommended Practices"
}
],
"publisher": {
"category": "coordinator",
"contact_details": "central@cisa.dhs.gov",
"name": "CISA",
"namespace": "https://www.cisa.gov/"
},
"references": [
{
"category": "self",
"summary": "ICS Advisory ICSA-12-138-01 JSON",
"url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2012/icsa-12-138-01.json"
},
{
"category": "self",
"summary": "ICS Advisory ICSA-12-138-01 - Web Version",
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-12-138-01"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/uscert/ics/alerts/ICS-ALERT-10-301-01"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/resources-tools/resources/ics-recommended-practices"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/topics/industrial-control-systems"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://us-cert.cisa.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/sites/default/files/publications/Cybersecurity_Best_Practices_for_Industrial_Control_Systems.pdf"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/uscert/ics/tips/ICS-TIP-12-146-01B"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/uscert/sites/default/files/publications/emailscams0905.pdf"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/uscert/ncas/tips/ST04-014"
}
],
"title": "Emerson DeltaV Multiple Vulnerabilities",
"tracking": {
"current_release_date": "2025-06-17T15:45:47.164093Z",
"generator": {
"date": "2025-06-17T15:45:47.164031Z",
"engine": {
"name": "CISA CSAF Generator",
"version": "1.0.0"
}
},
"id": "ICSA-12-138-01",
"initial_release_date": "2012-02-18T07:00:00.000000Z",
"revision_history": [
{
"date": "2012-02-18T07:00:00.000000Z",
"legacy_version": "Initial",
"number": "1",
"summary": "Initial Publication"
},
{
"date": "2025-06-17T15:45:47.164093Z",
"legacy_version": "CSAF Conversion",
"number": "2",
"summary": "Advisory converted into a CSAF"
}
],
"status": "final",
"version": "2"
}
},
"product_tree": {
"branches": [
{
"branches": [
{
"branches": [
{
"category": "product_version_range",
"name": "9.3.1|10.3.1|11.3|11.3.1",
"product": {
"name": "Emerson DeltaV: 9.3.1|10.3.1|11.3|11.3.1",
"product_id": "CSAFPID-0001"
}
}
],
"category": "product_name",
"name": "DeltaV"
},
{
"branches": [
{
"category": "product_version_range",
"name": "9.3.1|10.3.1|11.3|11.3.1",
"product": {
"name": "Emerson DeltaV Workstations: 9.3.1|10.3.1|11.3|11.3.1",
"product_id": "CSAFPID-0002"
}
}
],
"category": "product_name",
"name": "DeltaV Workstations"
},
{
"branches": [
{
"category": "product_version",
"name": "V5.0.0.6",
"product": {
"name": "Emerson DeltaV ProEssentials Scientific Graph: V5.0.0.6",
"product_id": "CSAFPID-0003"
}
}
],
"category": "product_name",
"name": "DeltaV ProEssentials Scientific Graph"
}
],
"category": "vendor",
"name": "Emerson"
}
]
},
"vulnerabilities": [
{
"cve": "CVE-2012-1817",
"cwe": {
"id": "CWE-119",
"name": "Improper Restriction of Operations within the Bounds of a Memory Buffer"
},
"notes": [
{
"category": "summary",
"text": "Buffer overflow in Emerson DeltaV and DeltaV Workstations 9.3.1, 10.3.1, 11.3, and 11.3.1 and DeltaV ProEssentials Scientific Graph 5.0.0.6 allows user-assisted remote attackers to execute arbitrary code or cause a denial of service (daemon crash) via an invalid field in a project file.",
"title": "Vulnerability Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Emerson has created a hotfix that resolves these vulnerabilities.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "Emerson has distributed a notification in KBA NK-1200-0091 ICS-CERT ADVISORY\u2014ICSA-12-137-01 Emerson Multiple Vulnerabilities: Impact and Recommended Actions to customers who own a DeltaV Control System, the notification provides details of the vulnerabilities, recommended mitigations, and instructions on obtaining and installing the hotfix.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
}
],
"scores": [
{
"cvss_v2": {
"baseScore": 7.5,
"vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
"version": "2.0"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
}
]
},
{
"cve": "CVE-2012-1816",
"cwe": {
"id": "CWE-400",
"name": "Uncontrolled Resource Consumption"
},
"notes": [
{
"category": "summary",
"text": "PORTSERV.exe in Emerson DeltaV and DeltaV Workstations 9.3.1, 10.3.1, 11.3, and 11.3.1 and DeltaV ProEssentials Scientific Graph 5.0.0.6 allows remote attackers to cause a denial of service (daemon crash) via a crafted (1) TCP or (2) UDP packet to port 111.",
"title": "Vulnerability Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Emerson has created a hotfix that resolves these vulnerabilities.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "Emerson has distributed a notification in KBA NK-1200-0091 ICS-CERT ADVISORY\u2014ICSA-12-137-01 Emerson Multiple Vulnerabilities: Impact and Recommended Actions to customers who own a DeltaV Control System, the notification provides details of the vulnerabilities, recommended mitigations, and instructions on obtaining and installing the hotfix.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
}
],
"scores": [
{
"cvss_v2": {
"baseScore": 5.0,
"vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P",
"version": "2.0"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
}
]
},
{
"cve": "CVE-2012-1818",
"cwe": {
"id": "CWE-618",
"name": "Exposed Unsafe ActiveX Method"
},
"notes": [
{
"category": "summary",
"text": "An unspecified ActiveX control in Emerson DeltaV and DeltaV Workstations 9.3.1, 10.3.1, 11.3, and 11.3.1 and DeltaV ProEssentials Scientific Graph 5.0.0.6 allows remote attackers to overwrite arbitrary files via unknown vectors.",
"title": "Vulnerability Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Emerson has created a hotfix that resolves these vulnerabilities.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "Emerson has distributed a notification in KBA NK-1200-0091 ICS-CERT ADVISORY\u2014ICSA-12-137-01 Emerson Multiple Vulnerabilities: Impact and Recommended Actions to customers who own a DeltaV Control System, the notification provides details of the vulnerabilities, recommended mitigations, and instructions on obtaining and installing the hotfix.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
}
],
"scores": [
{
"cvss_v2": {
"baseScore": 6.4,
"vectorString": "AV:N/AC:L/Au:N/C:N/I:P/A:P",
"version": "2.0"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
}
]
},
{
"cve": "CVE-2012-1814",
"cwe": {
"id": "CWE-79",
"name": "Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)"
},
"notes": [
{
"category": "summary",
"text": "Cross-site scripting (XSS) vulnerability in Emerson DeltaV and DeltaV Workstations 9.3.1, 10.3.1, 11.3, and 11.3.1 and DeltaV ProEssentials Scientific Graph 5.0.0.6 allows remote attackers to inject arbitrary web script or HTML via unspecified vectors.",
"title": "Vulnerability Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Emerson has created a hotfix that resolves these vulnerabilities.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "Emerson has distributed a notification in KBA NK-1200-0091 ICS-CERT ADVISORY\u2014ICSA-12-137-01 Emerson Multiple Vulnerabilities: Impact and Recommended Actions to customers who own a DeltaV Control System, the notification provides details of the vulnerabilities, recommended mitigations, and instructions on obtaining and installing the hotfix.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
}
],
"scores": [
{
"cvss_v2": {
"baseScore": 4.3,
"vectorString": "AV:N/AC:M/Au:N/C:N/I:P/A:N",
"version": "2.0"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
}
]
},
{
"cve": "CVE-2012-1815",
"cwe": {
"id": "CWE-89",
"name": "Improper Neutralization of Special Elements used in an SQL Command (\u0027SQL Injection\u0027)"
},
"notes": [
{
"category": "summary",
"text": "SQL injection vulnerability in Emerson DeltaV and DeltaV Workstations 9.3.1, 10.3.1, 11.3, and 11.3.1 and DeltaV ProEssentials Scientific Graph 5.0.0.6 allows remote attackers to execute arbitrary SQL commands via unspecified vectors.",
"title": "Vulnerability Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Emerson has created a hotfix that resolves these vulnerabilities.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "Emerson has distributed a notification in KBA NK-1200-0091 ICS-CERT ADVISORY\u2014ICSA-12-137-01 Emerson Multiple Vulnerabilities: Impact and Recommended Actions to customers who own a DeltaV Control System, the notification provides details of the vulnerabilities, recommended mitigations, and instructions on obtaining and installing the hotfix.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
}
],
"scores": [
{
"cvss_v2": {
"baseScore": 7.5,
"vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
"version": "2.0"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
}
]
}
]
}
VAR-201206-0260
Vulnerability from variot - Updated: 2025-04-11 22:53Buffer overflow in Emerson DeltaV and DeltaV Workstations 9.3.1, 10.3.1, 11.3, and 11.3.1 and DeltaV ProEssentials Scientific Graph 5.0.0.6 allows user-assisted remote attackers to execute arbitrary code or cause a denial of service (daemon crash) via an invalid field in a project file. Emerson Electric is a diversified global manufacturer. Provides network energy, process management, industrial automation, environmental optimization technology, tools and storage. Multiple DeltaV Products are prone to multiple remote vulnerabilities. Exploiting these issues could allow an attacker to steal cookie-based authentication credentials, to access or modify data, to exploit latent vulnerabilities in the underlying database, to execute arbitrary code, to overwrite arbitrary files on the victim's computer in the context of the vulnerable application that is using the ActiveX control (typically Internet Explorer),or to cause a denial-of-service condition. Other attacks are possible. ----------------------------------------------------------------------
Become a PSI 3.0 beta tester! Test-drive the new beta version and tell us what you think about its extended automatic update function and significantly enhanced user-interface. Download it here! http://secunia.com/psi_30_beta_launch
TITLE: DeltaV Products Multiple Vulnerabilities
SECUNIA ADVISORY ID: SA49210
VERIFY ADVISORY: Secunia.com http://secunia.com/advisories/49210/ Customer Area (Credentials Required) https://ca.secunia.com/?page=viewadvisory&vuln_id=49210
RELEASE DATE: 2012-05-17
DISCUSS ADVISORY: http://secunia.com/advisories/49210/#comments
AVAILABLE ON SITE AND IN CUSTOMER AREA: * Last Update * Popularity * Comments * Criticality Level * Impact * Where * Solution Status * Operating System / Software * CVE Reference(s)
http://secunia.com/advisories/49210/
ONLY AVAILABLE IN CUSTOMER AREA: * Authentication Level * Report Reliability * Secunia PoC * Secunia Analysis * Systems Affected * Approve Distribution * Remediation Status * Secunia CVSS Score * CVSS
https://ca.secunia.com/?page=viewadvisory&vuln_id=49210
ONLY AVAILABLE WITH SECUNIA CSI AND SECUNIA PSI: * AUTOMATED SCANNING
http://secunia.com/vulnerability_scanning/personal/ http://secunia.com/vulnerability_scanning/corporate/wsus_sccm_3rd_third_party_patching/
DESCRIPTION: Multiple vulnerabilities have been reported in DeltaV products, which can be exploited by malicious people to conduct cross-site scripting attacks, SQL injection attacks, cause a DoS (Denial of Service), and compromise a vulnerable system.
1) Certain unspecified input is not properly sanitised before being returned to the user. This can be exploited to execute arbitrary HTML and script code in a user's browser session in context of an affected site.
2) Certain unspecified input is not properly sanitised before being used in SQL queries. This can be exploited to manipulate SQL queries by injecting arbitrary SQL code.
3) An error within PORTSERV.exe can be exploited to cause a crash via a specially crafted packet sent to TCP or UDP port 111.
4) An error within the processing of certain fields in project files can be exploited to cause a buffer overflow via a specially crafted project file.
5) An insecure method within an ActiveX control can be exploited to overwrite arbitrary files.
Successful exploitation of vulnerabilities #4 and #5 may allow execution of arbitrary code.
The vulnerabilities are reported in the following applications: * DeltaV and DeltaV Workstations versions 9.3.1, 10.3.1, 11.3, and 11.3.1 * DeltaV ProEssentials Scientific Graph version 5.0.0.6
SOLUTION: Apply hotfix (please contact the vendor for more information).
PROVIDED AND/OR DISCOVERED BY: ICS-CERT credits Kuang-Chun Hung, Security Research and Service Institute.
ORIGINAL ADVISORY: ICS-CERT: http://www.us-cert.gov/control_systems/pdf/ICSA-12-137-01.pdf
OTHER REFERENCES: Further details available in Customer Area: http://secunia.com/vulnerability_intelligence/
DEEP LINKS: Further details available in Customer Area: http://secunia.com/vulnerability_intelligence/
EXTENDED DESCRIPTION: Further details available in Customer Area: http://secunia.com/vulnerability_intelligence/
EXTENDED SOLUTION: Further details available in Customer Area: http://secunia.com/vulnerability_intelligence/
EXPLOIT: Further details available in Customer Area: http://secunia.com/vulnerability_intelligence/
About: This Advisory was delivered by Secunia as a free service to help private users keeping their systems up to date against the latest vulnerabilities.
Subscribe: http://secunia.com/advisories/secunia_security_advisories/
Definitions: (Criticality, Where etc.) http://secunia.com/advisories/about_secunia_advisories/
Please Note: Secunia recommends that you verify all advisories you receive by clicking the link. Secunia NEVER sends attached files with advisories. Secunia does not advise people to install third party patches, only use those supplied by the vendor.
Unsubscribe: Secunia Security Advisories http://secunia.com/sec_adv_unsubscribe/?email=packet%40packetstormsecurity.org
Show details on source website
{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-201206-0260",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "deltav proessentials scientific graph",
"scope": "eq",
"trust": 1.6,
"vendor": "emerson",
"version": "5.0.0.6"
},
{
"model": "deltav workstation",
"scope": "eq",
"trust": 1.6,
"vendor": "emerson",
"version": "11.3.1"
},
{
"model": "deltav",
"scope": "eq",
"trust": 1.6,
"vendor": "emerson",
"version": "11.3"
},
{
"model": "deltav",
"scope": "eq",
"trust": 1.6,
"vendor": "emerson",
"version": "9.3.1"
},
{
"model": "deltav workstation",
"scope": "eq",
"trust": 1.6,
"vendor": "emerson",
"version": "11.3"
},
{
"model": "deltav",
"scope": "eq",
"trust": 1.6,
"vendor": "emerson",
"version": "10.3.1"
},
{
"model": "deltav workstation",
"scope": "eq",
"trust": 1.6,
"vendor": "emerson",
"version": "9.3.1"
},
{
"model": "deltav",
"scope": "eq",
"trust": 1.6,
"vendor": "emerson",
"version": "11.3.1"
},
{
"model": "deltav workstation",
"scope": "eq",
"trust": 1.6,
"vendor": "emerson",
"version": "10.3.1"
},
{
"model": "electric co deltav",
"scope": "eq",
"trust": 0.9,
"vendor": "emerson",
"version": "9"
},
{
"model": "electric co deltav",
"scope": "eq",
"trust": 0.9,
"vendor": "emerson",
"version": "11"
},
{
"model": "electric co deltav",
"scope": "eq",
"trust": 0.9,
"vendor": "emerson",
"version": "10"
},
{
"model": "electric co deltav proessentials scientific graph",
"scope": "eq",
"trust": 0.9,
"vendor": "emerson",
"version": "5"
},
{
"model": "electric co deltav workstations",
"scope": "eq",
"trust": 0.9,
"vendor": "emerson",
"version": "11"
},
{
"model": "electric co deltav workstations",
"scope": "eq",
"trust": 0.9,
"vendor": "emerson",
"version": "10"
},
{
"model": "electric co deltav workstations",
"scope": "eq",
"trust": 0.9,
"vendor": "emerson",
"version": "9"
},
{
"model": "deltav",
"scope": "eq",
"trust": 0.8,
"vendor": "emerson",
"version": "v10.3.1"
},
{
"model": "deltav",
"scope": "eq",
"trust": 0.8,
"vendor": "emerson",
"version": "v11.3 and v11.3.1"
},
{
"model": "deltav",
"scope": "eq",
"trust": 0.8,
"vendor": "emerson",
"version": "v9.3.1"
},
{
"model": "deltav proessentials scientific graph",
"scope": "eq",
"trust": 0.8,
"vendor": "emerson",
"version": "v5.0.0.6"
},
{
"model": "deltav workstation",
"scope": "eq",
"trust": 0.8,
"vendor": "emerson",
"version": "v10.3.1"
},
{
"model": "deltav workstation",
"scope": "eq",
"trust": 0.8,
"vendor": "emerson",
"version": "v11.3 and v11.3.1"
},
{
"model": "deltav workstation",
"scope": "eq",
"trust": 0.8,
"vendor": "emerson",
"version": "v9.3.1"
},
{
"model": null,
"scope": "eq",
"trust": 0.2,
"vendor": "deltav",
"version": "9.3.1"
},
{
"model": null,
"scope": "eq",
"trust": 0.2,
"vendor": "deltav",
"version": "10.3.1"
},
{
"model": null,
"scope": "eq",
"trust": 0.2,
"vendor": "deltav",
"version": "11.3"
},
{
"model": null,
"scope": "eq",
"trust": 0.2,
"vendor": "deltav",
"version": "11.3.1"
},
{
"model": null,
"scope": "eq",
"trust": 0.2,
"vendor": "deltav proessentials scientific graph",
"version": "5.0.0.6"
},
{
"model": null,
"scope": "eq",
"trust": 0.2,
"vendor": "deltav workstation",
"version": "9.3.1"
},
{
"model": null,
"scope": "eq",
"trust": 0.2,
"vendor": "deltav workstation",
"version": "10.3.1"
},
{
"model": null,
"scope": "eq",
"trust": 0.2,
"vendor": "deltav workstation",
"version": "11.3"
},
{
"model": null,
"scope": "eq",
"trust": 0.2,
"vendor": "deltav workstation",
"version": "11.3.1"
}
],
"sources": [
{
"db": "IVD",
"id": "c502eb7a-2353-11e6-abef-000c29c66e3d"
},
{
"db": "CNVD",
"id": "CNVD-2012-2641"
},
{
"db": "BID",
"id": "53591"
},
{
"db": "JVNDB",
"id": "JVNDB-2012-002656"
},
{
"db": "CNNVD",
"id": "CNNVD-201205-321"
},
{
"db": "NVD",
"id": "CVE-2012-1817"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"cpe_match": [
{
"cpe22Uri": "cpe:/a:emerson:deltav",
"vulnerable": true
},
{
"cpe22Uri": "cpe:/a:emerson:deltav_proessentials_scientific_graph",
"vulnerable": true
},
{
"cpe22Uri": "cpe:/a:emerson:deltav_workstation",
"vulnerable": true
}
],
"operator": "OR"
}
]
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2012-002656"
}
]
},
"credits": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/credits#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Kuang-Chun Hung of Security Research and Service Institute.",
"sources": [
{
"db": "BID",
"id": "53591"
}
],
"trust": 0.3
},
"cve": "CVE-2012-1817",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "nvd@nist.gov",
"availabilityImpact": "PARTIAL",
"baseScore": 7.5,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 10.0,
"id": "CVE-2012-1817",
"impactScore": 6.4,
"integrityImpact": "PARTIAL",
"severity": "HIGH",
"trust": 1.8,
"vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
"version": "2.0"
},
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "IVD",
"availabilityImpact": "PARTIAL",
"baseScore": 7.5,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 10.0,
"id": "c502eb7a-2353-11e6-abef-000c29c66e3d",
"impactScore": 6.4,
"integrityImpact": "PARTIAL",
"severity": "HIGH",
"trust": 0.2,
"vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
"version": "2.9 [IVD]"
}
],
"cvssV3": [],
"severity": [
{
"author": "nvd@nist.gov",
"id": "CVE-2012-1817",
"trust": 1.0,
"value": "HIGH"
},
{
"author": "NVD",
"id": "CVE-2012-1817",
"trust": 0.8,
"value": "High"
},
{
"author": "CNNVD",
"id": "CNNVD-201205-321",
"trust": 0.6,
"value": "HIGH"
},
{
"author": "IVD",
"id": "c502eb7a-2353-11e6-abef-000c29c66e3d",
"trust": 0.2,
"value": "HIGH"
}
]
}
],
"sources": [
{
"db": "IVD",
"id": "c502eb7a-2353-11e6-abef-000c29c66e3d"
},
{
"db": "JVNDB",
"id": "JVNDB-2012-002656"
},
{
"db": "CNNVD",
"id": "CNNVD-201205-321"
},
{
"db": "NVD",
"id": "CVE-2012-1817"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Buffer overflow in Emerson DeltaV and DeltaV Workstations 9.3.1, 10.3.1, 11.3, and 11.3.1 and DeltaV ProEssentials Scientific Graph 5.0.0.6 allows user-assisted remote attackers to execute arbitrary code or cause a denial of service (daemon crash) via an invalid field in a project file. Emerson Electric is a diversified global manufacturer. Provides network energy, process management, industrial automation, environmental optimization technology, tools and storage. Multiple DeltaV Products are prone to multiple remote vulnerabilities. \nExploiting these issues could allow an attacker to steal cookie-based authentication credentials, to access or modify data, to exploit latent vulnerabilities in the underlying database, to execute arbitrary code, to overwrite arbitrary files on the victim\u0027s computer in the context of the vulnerable application that is using the ActiveX control (typically Internet Explorer),or to cause a denial-of-service condition. Other attacks are possible. ----------------------------------------------------------------------\n\nBecome a PSI 3.0 beta tester!\nTest-drive the new beta version and tell us what you think about its extended automatic update function and significantly enhanced user-interface. \nDownload it here!\nhttp://secunia.com/psi_30_beta_launch\n\n----------------------------------------------------------------------\n\nTITLE:\nDeltaV Products Multiple Vulnerabilities\n\nSECUNIA ADVISORY ID:\nSA49210\n\nVERIFY ADVISORY:\nSecunia.com\nhttp://secunia.com/advisories/49210/\nCustomer Area (Credentials Required)\nhttps://ca.secunia.com/?page=viewadvisory\u0026vuln_id=49210\n\nRELEASE DATE:\n2012-05-17\n\nDISCUSS ADVISORY:\nhttp://secunia.com/advisories/49210/#comments\n\nAVAILABLE ON SITE AND IN CUSTOMER AREA:\n * Last Update\n * Popularity\n * Comments\n * Criticality Level\n * Impact\n * Where\n * Solution Status\n * Operating System / Software\n * CVE Reference(s)\n\nhttp://secunia.com/advisories/49210/\n\nONLY AVAILABLE IN CUSTOMER AREA:\n * Authentication Level\n * Report Reliability\n * Secunia PoC\n * Secunia Analysis\n * Systems Affected\n * Approve Distribution\n * Remediation Status\n * Secunia CVSS Score\n * CVSS\n\nhttps://ca.secunia.com/?page=viewadvisory\u0026vuln_id=49210\n\nONLY AVAILABLE WITH SECUNIA CSI AND SECUNIA PSI:\n * AUTOMATED SCANNING\n\nhttp://secunia.com/vulnerability_scanning/personal/\nhttp://secunia.com/vulnerability_scanning/corporate/wsus_sccm_3rd_third_party_patching/\n\nDESCRIPTION:\nMultiple vulnerabilities have been reported in DeltaV products, which\ncan be exploited by malicious people to conduct cross-site scripting\nattacks, SQL injection attacks, cause a DoS (Denial of Service), and\ncompromise a vulnerable system. \n\n1) Certain unspecified input is not properly sanitised before being\nreturned to the user. This can be exploited to execute arbitrary HTML\nand script code in a user\u0027s browser session in context of an affected\nsite. \n\n2) Certain unspecified input is not properly sanitised before being\nused in SQL queries. This can be exploited to manipulate SQL queries\nby injecting arbitrary SQL code. \n\n3) An error within PORTSERV.exe can be exploited to cause a crash via\na specially crafted packet sent to TCP or UDP port 111. \n\n4) An error within the processing of certain fields in project files\ncan be exploited to cause a buffer overflow via a specially crafted\nproject file. \n\n5) An insecure method within an ActiveX control can be exploited to\noverwrite arbitrary files. \n\nSuccessful exploitation of vulnerabilities #4 and #5 may allow\nexecution of arbitrary code. \n\nThe vulnerabilities are reported in the following applications:\n* DeltaV and DeltaV Workstations versions 9.3.1, 10.3.1, 11.3, and\n11.3.1\n* DeltaV ProEssentials Scientific Graph version 5.0.0.6\n\nSOLUTION:\nApply hotfix (please contact the vendor for more information). \n\nPROVIDED AND/OR DISCOVERED BY:\nICS-CERT credits Kuang-Chun Hung, Security Research and Service\nInstitute. \n\nORIGINAL ADVISORY:\nICS-CERT:\nhttp://www.us-cert.gov/control_systems/pdf/ICSA-12-137-01.pdf\n\nOTHER REFERENCES:\nFurther details available in Customer Area:\nhttp://secunia.com/vulnerability_intelligence/\n\nDEEP LINKS:\nFurther details available in Customer Area:\nhttp://secunia.com/vulnerability_intelligence/\n\nEXTENDED DESCRIPTION:\nFurther details available in Customer Area:\nhttp://secunia.com/vulnerability_intelligence/\n\nEXTENDED SOLUTION:\nFurther details available in Customer Area:\nhttp://secunia.com/vulnerability_intelligence/\n\nEXPLOIT:\nFurther details available in Customer Area:\nhttp://secunia.com/vulnerability_intelligence/\n\n----------------------------------------------------------------------\n\nAbout:\nThis Advisory was delivered by Secunia as a free service to help\nprivate users keeping their systems up to date against the latest\nvulnerabilities. \n\nSubscribe:\nhttp://secunia.com/advisories/secunia_security_advisories/\n\nDefinitions: (Criticality, Where etc.)\nhttp://secunia.com/advisories/about_secunia_advisories/\n\n\nPlease Note:\nSecunia recommends that you verify all advisories you receive by\nclicking the link. \nSecunia NEVER sends attached files with advisories. \nSecunia does not advise people to install third party patches, only\nuse those supplied by the vendor. \n\n----------------------------------------------------------------------\n\nUnsubscribe: Secunia Security Advisories\nhttp://secunia.com/sec_adv_unsubscribe/?email=packet%40packetstormsecurity.org\n\n----------------------------------------------------------------------\n\n\n",
"sources": [
{
"db": "NVD",
"id": "CVE-2012-1817"
},
{
"db": "JVNDB",
"id": "JVNDB-2012-002656"
},
{
"db": "CNVD",
"id": "CNVD-2012-2641"
},
{
"db": "BID",
"id": "53591"
},
{
"db": "IVD",
"id": "c502eb7a-2353-11e6-abef-000c29c66e3d"
},
{
"db": "PACKETSTORM",
"id": "112840"
}
],
"trust": 2.7
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2012-1817",
"trust": 3.5
},
{
"db": "ICS CERT",
"id": "ICSA-12-138-01",
"trust": 2.7
},
{
"db": "SECUNIA",
"id": "49210",
"trust": 1.8
},
{
"db": "BID",
"id": "53591",
"trust": 1.3
},
{
"db": "OSVDB",
"id": "82013",
"trust": 1.0
},
{
"db": "CNVD",
"id": "CNVD-2012-2641",
"trust": 0.8
},
{
"db": "CNNVD",
"id": "CNNVD-201205-321",
"trust": 0.8
},
{
"db": "JVNDB",
"id": "JVNDB-2012-002656",
"trust": 0.8
},
{
"db": "ICS CERT",
"id": "ICSA-12-137-01",
"trust": 0.7
},
{
"db": "NSFOCUS",
"id": "19718",
"trust": 0.6
},
{
"db": "IVD",
"id": "C502EB7A-2353-11E6-ABEF-000C29C66E3D",
"trust": 0.2
},
{
"db": "PACKETSTORM",
"id": "112840",
"trust": 0.1
}
],
"sources": [
{
"db": "IVD",
"id": "c502eb7a-2353-11e6-abef-000c29c66e3d"
},
{
"db": "CNVD",
"id": "CNVD-2012-2641"
},
{
"db": "BID",
"id": "53591"
},
{
"db": "JVNDB",
"id": "JVNDB-2012-002656"
},
{
"db": "PACKETSTORM",
"id": "112840"
},
{
"db": "CNNVD",
"id": "CNNVD-201205-321"
},
{
"db": "NVD",
"id": "CVE-2012-1817"
}
]
},
"id": "VAR-201206-0260",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "IVD",
"id": "c502eb7a-2353-11e6-abef-000c29c66e3d"
},
{
"db": "CNVD",
"id": "CNVD-2012-2641"
}
],
"trust": 1.6067765666666667
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"ICS"
],
"sub_category": null,
"trust": 0.8
}
],
"sources": [
{
"db": "IVD",
"id": "c502eb7a-2353-11e6-abef-000c29c66e3d"
},
{
"db": "CNVD",
"id": "CNVD-2012-2641"
}
]
},
"last_update_date": "2025-04-11T22:53:41.823000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "DeltaV Workstation Hardware",
"trust": 0.8,
"url": "http://www2.emersonprocess.com/siteadmincenter/PM%20DeltaV%20Documents/ProductDataSheets/PDS_WkstationHdware.pdf"
},
{
"title": "Top Page",
"trust": 0.8,
"url": "http://www.emerson.com/en-US/Pages/default.aspx"
},
{
"title": "\u65e5\u672c\u30a8\u30de\u30bd\u30f3\u682a\u5f0f\u4f1a\u793e",
"trust": 0.8,
"url": "http://www.emerson.co.jp/index.html"
},
{
"title": "\u5206\u6563\u578b\u5236\u5fa1\u30b7\u30b9\u30c6\u30e0\uff08DCS\uff09 DeltaV\u30b7\u30b9\u30c6\u30e0",
"trust": 0.8,
"url": "http://www.emerson.co.jp/div/epm/product5_1.html"
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2012-002656"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-20",
"trust": 1.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2012-002656"
},
{
"db": "NVD",
"id": "CVE-2012-1817"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 2.7,
"url": "http://www.us-cert.gov/control_systems/pdf/icsa-12-138-01.pdf"
},
{
"trust": 1.6,
"url": "http://secunia.com/advisories/49210"
},
{
"trust": 1.0,
"url": "http://osvdb.org/82013"
},
{
"trust": 1.0,
"url": "http://www.securityfocus.com/bid/53591"
},
{
"trust": 0.8,
"url": "http://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2012-1817"
},
{
"trust": 0.8,
"url": "http://web.nvd.nist.gov/view/vuln/detail?vulnid=cve-2012-1817"
},
{
"trust": 0.7,
"url": "http://www.us-cert.gov/control_systems/pdf/icsa-12-137-01.pdf"
},
{
"trust": 0.6,
"url": "http://www.nsfocus.net/vulndb/19718"
},
{
"trust": 0.3,
"url": "http://www2.emersonprocess.com/en-us/brands/deltav/pages/index.aspx"
},
{
"trust": 0.1,
"url": "http://secunia.com/advisories/49210/"
},
{
"trust": 0.1,
"url": "http://secunia.com/advisories/49210/#comments"
},
{
"trust": 0.1,
"url": "http://secunia.com/psi_30_beta_launch"
},
{
"trust": 0.1,
"url": "http://secunia.com/vulnerability_intelligence/"
},
{
"trust": 0.1,
"url": "http://secunia.com/vulnerability_scanning/corporate/wsus_sccm_3rd_third_party_patching/"
},
{
"trust": 0.1,
"url": "http://secunia.com/advisories/secunia_security_advisories/"
},
{
"trust": 0.1,
"url": "http://secunia.com/vulnerability_scanning/personal/"
},
{
"trust": 0.1,
"url": "http://secunia.com/sec_adv_unsubscribe/?email=packet%40packetstormsecurity.org"
},
{
"trust": 0.1,
"url": "https://ca.secunia.com/?page=viewadvisory\u0026vuln_id=49210"
},
{
"trust": 0.1,
"url": "http://secunia.com/advisories/about_secunia_advisories/"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2012-2641"
},
{
"db": "BID",
"id": "53591"
},
{
"db": "JVNDB",
"id": "JVNDB-2012-002656"
},
{
"db": "PACKETSTORM",
"id": "112840"
},
{
"db": "CNNVD",
"id": "CNNVD-201205-321"
},
{
"db": "NVD",
"id": "CVE-2012-1817"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "IVD",
"id": "c502eb7a-2353-11e6-abef-000c29c66e3d"
},
{
"db": "CNVD",
"id": "CNVD-2012-2641"
},
{
"db": "BID",
"id": "53591"
},
{
"db": "JVNDB",
"id": "JVNDB-2012-002656"
},
{
"db": "PACKETSTORM",
"id": "112840"
},
{
"db": "CNNVD",
"id": "CNNVD-201205-321"
},
{
"db": "NVD",
"id": "CVE-2012-1817"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2012-05-21T00:00:00",
"db": "IVD",
"id": "c502eb7a-2353-11e6-abef-000c29c66e3d"
},
{
"date": "2012-05-21T00:00:00",
"db": "CNVD",
"id": "CNVD-2012-2641"
},
{
"date": "2012-05-16T00:00:00",
"db": "BID",
"id": "53591"
},
{
"date": "2012-06-12T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2012-002656"
},
{
"date": "2012-05-18T06:07:17",
"db": "PACKETSTORM",
"id": "112840"
},
{
"date": "2012-05-21T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201205-321"
},
{
"date": "2012-06-08T18:55:01.657000",
"db": "NVD",
"id": "CVE-2012-1817"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2012-05-21T00:00:00",
"db": "CNVD",
"id": "CNVD-2012-2641"
},
{
"date": "2012-05-30T22:50:00",
"db": "BID",
"id": "53591"
},
{
"date": "2012-06-12T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2012-002656"
},
{
"date": "2012-05-21T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201205-321"
},
{
"date": "2025-04-11T00:51:21.963000",
"db": "NVD",
"id": "CVE-2012-1817"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-201205-321"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "DeltaV Multiple Product Buffer Overflow Vulnerabilities",
"sources": [
{
"db": "IVD",
"id": "c502eb7a-2353-11e6-abef-000c29c66e3d"
},
{
"db": "CNVD",
"id": "CNVD-2012-2641"
},
{
"db": "CNNVD",
"id": "CNNVD-201205-321"
}
],
"trust": 1.4
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Input validation",
"sources": [
{
"db": "IVD",
"id": "c502eb7a-2353-11e6-abef-000c29c66e3d"
},
{
"db": "CNNVD",
"id": "CNNVD-201205-321"
}
],
"trust": 0.8
}
}
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.