    CVE-2013-3075 (GCVE-0-2013-3075)

    Vulnerability from nvd – Published: 2013-04-19 10:00 – Updated: 2024-09-17 00:57
    VLAI
    Summary
    Multiple buffer overflows in ActUWzd.dll 1.0.0.1 in Mitsubishi MX Component 3, as distributed in Citect CitectFacilities 7.10 and CitectScada 7.10r1, allow remote attackers to execute arbitrary code via a long string, as demonstrated by a long WzTitle property value to a certain ActiveX control.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Assigner
    References
    URL Tags
    http://www.exploit-db.com/exploits/24886/ exploitx_refsource_EXPLOIT-DB
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-06T16:00:09.518Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "name": "24886",
                "tags": [
                  "exploit",
                  "x_refsource_EXPLOIT-DB",
                  "x_transferred"
                ],
                "url": "http://www.exploit-db.com/exploits/24886/"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Multiple buffer overflows in ActUWzd.dll 1.0.0.1 in Mitsubishi MX Component 3, as distributed in Citect CitectFacilities 7.10 and CitectScada 7.10r1, allow remote attackers to execute arbitrary code via a long string, as demonstrated by a long WzTitle property value to a certain ActiveX control."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2013-04-19T10:00:00.000Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "name": "24886",
              "tags": [
                "exploit",
                "x_refsource_EXPLOIT-DB"
              ],
              "url": "http://www.exploit-db.com/exploits/24886/"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "ics-cert@hq.dhs.gov",
              "ID": "CVE-2013-3075",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Multiple buffer overflows in ActUWzd.dll 1.0.0.1 in Mitsubishi MX Component 3, as distributed in Citect CitectFacilities 7.10 and CitectScada 7.10r1, allow remote attackers to execute arbitrary code via a long string, as demonstrated by a long WzTitle property value to a certain ActiveX control."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "24886",
                  "refsource": "EXPLOIT-DB",
                  "url": "http://www.exploit-db.com/exploits/24886/"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2013-3075",
        "datePublished": "2013-04-19T10:00:00.000Z",
        "dateReserved": "2013-04-15T00:00:00.000Z",
        "dateUpdated": "2024-09-17T00:57:04.612Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2011-5163 (GCVE-0-2011-5163)

    Vulnerability from nvd – Published: 2012-09-15 17:00 – Updated: 2024-09-17 00:35
    VLAI
    Summary
    Buffer overflow in an unspecified third-party component in the Batch module for Schneider Electric CitectSCADA before 7.20 and Mitsubishi MX4 SCADA before 7.20 allows local users to execute arbitrary code via a long string in a login sequence.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Assigner
    References
    URL Tags
    http://www.citect.com/citectscada-batch x_refsource_CONFIRM
    http://www.osvdb.org/76937 vdb-entryx_refsource_OSVDB
    http://www.us-cert.gov/control_systems/pdf/ICSA-1… x_refsource_MISC
    http://secunia.com/advisories/46779 third-party-advisoryx_refsource_SECUNIA
    http://www.securitytracker.com/id?1026306 vdb-entryx_refsource_SECTRACK
    https://my.mitsubishi-automation.com/downloads_sh… x_refsource_CONFIRM
    http://secunia.com/advisories/46786 third-party-advisoryx_refsource_SECUNIA
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-07T00:30:46.763Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "http://www.citect.com/citectscada-batch"
              },
              {
                "name": "76937",
                "tags": [
                  "vdb-entry",
                  "x_refsource_OSVDB",
                  "x_transferred"
                ],
                "url": "http://www.osvdb.org/76937"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-11-279-02.pdf"
              },
              {
                "name": "46779",
                "tags": [
                  "third-party-advisory",
                  "x_refsource_SECUNIA",
                  "x_transferred"
                ],
                "url": "http://secunia.com/advisories/46779"
              },
              {
                "name": "1026306",
                "tags": [
                  "vdb-entry",
                  "x_refsource_SECTRACK",
                  "x_transferred"
                ],
                "url": "http://www.securitytracker.com/id?1026306"
              },
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://my.mitsubishi-automation.com/downloads_show.php?portal_id=1\u0026doc_type=safety\u0026scat=2\u0026sstr=MX4%2CSCADA"
              },
              {
                "name": "46786",
                "tags": [
                  "third-party-advisory",
                  "x_refsource_SECUNIA",
                  "x_transferred"
                ],
                "url": "http://secunia.com/advisories/46786"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Buffer overflow in an unspecified third-party component in the Batch module for Schneider Electric CitectSCADA before 7.20 and Mitsubishi MX4 SCADA before 7.20 allows local users to execute arbitrary code via a long string in a login sequence."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2012-09-15T17:00:00.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "http://www.citect.com/citectscada-batch"
            },
            {
              "name": "76937",
              "tags": [
                "vdb-entry",
                "x_refsource_OSVDB"
              ],
              "url": "http://www.osvdb.org/76937"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-11-279-02.pdf"
            },
            {
              "name": "46779",
              "tags": [
                "third-party-advisory",
                "x_refsource_SECUNIA"
              ],
              "url": "http://secunia.com/advisories/46779"
            },
            {
              "name": "1026306",
              "tags": [
                "vdb-entry",
                "x_refsource_SECTRACK"
              ],
              "url": "http://www.securitytracker.com/id?1026306"
            },
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://my.mitsubishi-automation.com/downloads_show.php?portal_id=1\u0026doc_type=safety\u0026scat=2\u0026sstr=MX4%2CSCADA"
            },
            {
              "name": "46786",
              "tags": [
                "third-party-advisory",
                "x_refsource_SECUNIA"
              ],
              "url": "http://secunia.com/advisories/46786"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cve@mitre.org",
              "ID": "CVE-2011-5163",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Buffer overflow in an unspecified third-party component in the Batch module for Schneider Electric CitectSCADA before 7.20 and Mitsubishi MX4 SCADA before 7.20 allows local users to execute arbitrary code via a long string in a login sequence."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "http://www.citect.com/citectscada-batch",
                  "refsource": "CONFIRM",
                  "url": "http://www.citect.com/citectscada-batch"
                },
                {
                  "name": "76937",
                  "refsource": "OSVDB",
                  "url": "http://www.osvdb.org/76937"
                },
                {
                  "name": "http://www.us-cert.gov/control_systems/pdf/ICSA-11-279-02.pdf",
                  "refsource": "MISC",
                  "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-11-279-02.pdf"
                },
                {
                  "name": "46779",
                  "refsource": "SECUNIA",
                  "url": "http://secunia.com/advisories/46779"
                },
                {
                  "name": "1026306",
                  "refsource": "SECTRACK",
                  "url": "http://www.securitytracker.com/id?1026306"
                },
                {
                  "name": "https://my.mitsubishi-automation.com/downloads_show.php?portal_id=1\u0026doc_type=safety\u0026scat=2\u0026sstr=MX4,SCADA",
                  "refsource": "CONFIRM",
                  "url": "https://my.mitsubishi-automation.com/downloads_show.php?portal_id=1\u0026doc_type=safety\u0026scat=2\u0026sstr=MX4,SCADA"
                },
                {
                  "name": "46786",
                  "refsource": "SECUNIA",
                  "url": "http://secunia.com/advisories/46786"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2011-5163",
        "datePublished": "2012-09-15T17:00:00.000Z",
        "dateReserved": "2012-09-15T00:00:00.000Z",
        "dateUpdated": "2024-09-17T00:35:30.905Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2013-3075 (GCVE-0-2013-3075)

    Vulnerability from cvelistv5 – Published: 2013-04-19 10:00 – Updated: 2024-09-17 00:57
    VLAI
    Summary
    Multiple buffer overflows in ActUWzd.dll 1.0.0.1 in Mitsubishi MX Component 3, as distributed in Citect CitectFacilities 7.10 and CitectScada 7.10r1, allow remote attackers to execute arbitrary code via a long string, as demonstrated by a long WzTitle property value to a certain ActiveX control.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Assigner
    References
    URL Tags
    http://www.exploit-db.com/exploits/24886/ exploitx_refsource_EXPLOIT-DB
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-06T16:00:09.518Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "name": "24886",
                "tags": [
                  "exploit",
                  "x_refsource_EXPLOIT-DB",
                  "x_transferred"
                ],
                "url": "http://www.exploit-db.com/exploits/24886/"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Multiple buffer overflows in ActUWzd.dll 1.0.0.1 in Mitsubishi MX Component 3, as distributed in Citect CitectFacilities 7.10 and CitectScada 7.10r1, allow remote attackers to execute arbitrary code via a long string, as demonstrated by a long WzTitle property value to a certain ActiveX control."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2013-04-19T10:00:00.000Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "name": "24886",
              "tags": [
                "exploit",
                "x_refsource_EXPLOIT-DB"
              ],
              "url": "http://www.exploit-db.com/exploits/24886/"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "ics-cert@hq.dhs.gov",
              "ID": "CVE-2013-3075",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Multiple buffer overflows in ActUWzd.dll 1.0.0.1 in Mitsubishi MX Component 3, as distributed in Citect CitectFacilities 7.10 and CitectScada 7.10r1, allow remote attackers to execute arbitrary code via a long string, as demonstrated by a long WzTitle property value to a certain ActiveX control."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "24886",
                  "refsource": "EXPLOIT-DB",
                  "url": "http://www.exploit-db.com/exploits/24886/"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2013-3075",
        "datePublished": "2013-04-19T10:00:00.000Z",
        "dateReserved": "2013-04-15T00:00:00.000Z",
        "dateUpdated": "2024-09-17T00:57:04.612Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2011-5163 (GCVE-0-2011-5163)

    Vulnerability from cvelistv5 – Published: 2012-09-15 17:00 – Updated: 2024-09-17 00:35
    VLAI
    Summary
    Buffer overflow in an unspecified third-party component in the Batch module for Schneider Electric CitectSCADA before 7.20 and Mitsubishi MX4 SCADA before 7.20 allows local users to execute arbitrary code via a long string in a login sequence.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Assigner
    References
    URL Tags
    http://www.citect.com/citectscada-batch x_refsource_CONFIRM
    http://www.osvdb.org/76937 vdb-entryx_refsource_OSVDB
    http://www.us-cert.gov/control_systems/pdf/ICSA-1… x_refsource_MISC
    http://secunia.com/advisories/46779 third-party-advisoryx_refsource_SECUNIA
    http://www.securitytracker.com/id?1026306 vdb-entryx_refsource_SECTRACK
    https://my.mitsubishi-automation.com/downloads_sh… x_refsource_CONFIRM
    http://secunia.com/advisories/46786 third-party-advisoryx_refsource_SECUNIA
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-07T00:30:46.763Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "http://www.citect.com/citectscada-batch"
              },
              {
                "name": "76937",
                "tags": [
                  "vdb-entry",
                  "x_refsource_OSVDB",
                  "x_transferred"
                ],
                "url": "http://www.osvdb.org/76937"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-11-279-02.pdf"
              },
              {
                "name": "46779",
                "tags": [
                  "third-party-advisory",
                  "x_refsource_SECUNIA",
                  "x_transferred"
                ],
                "url": "http://secunia.com/advisories/46779"
              },
              {
                "name": "1026306",
                "tags": [
                  "vdb-entry",
                  "x_refsource_SECTRACK",
                  "x_transferred"
                ],
                "url": "http://www.securitytracker.com/id?1026306"
              },
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://my.mitsubishi-automation.com/downloads_show.php?portal_id=1\u0026doc_type=safety\u0026scat=2\u0026sstr=MX4%2CSCADA"
              },
              {
                "name": "46786",
                "tags": [
                  "third-party-advisory",
                  "x_refsource_SECUNIA",
                  "x_transferred"
                ],
                "url": "http://secunia.com/advisories/46786"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Buffer overflow in an unspecified third-party component in the Batch module for Schneider Electric CitectSCADA before 7.20 and Mitsubishi MX4 SCADA before 7.20 allows local users to execute arbitrary code via a long string in a login sequence."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2012-09-15T17:00:00.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "http://www.citect.com/citectscada-batch"
            },
            {
              "name": "76937",
              "tags": [
                "vdb-entry",
                "x_refsource_OSVDB"
              ],
              "url": "http://www.osvdb.org/76937"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-11-279-02.pdf"
            },
            {
              "name": "46779",
              "tags": [
                "third-party-advisory",
                "x_refsource_SECUNIA"
              ],
              "url": "http://secunia.com/advisories/46779"
            },
            {
              "name": "1026306",
              "tags": [
                "vdb-entry",
                "x_refsource_SECTRACK"
              ],
              "url": "http://www.securitytracker.com/id?1026306"
            },
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://my.mitsubishi-automation.com/downloads_show.php?portal_id=1\u0026doc_type=safety\u0026scat=2\u0026sstr=MX4%2CSCADA"
            },
            {
              "name": "46786",
              "tags": [
                "third-party-advisory",
                "x_refsource_SECUNIA"
              ],
              "url": "http://secunia.com/advisories/46786"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cve@mitre.org",
              "ID": "CVE-2011-5163",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Buffer overflow in an unspecified third-party component in the Batch module for Schneider Electric CitectSCADA before 7.20 and Mitsubishi MX4 SCADA before 7.20 allows local users to execute arbitrary code via a long string in a login sequence."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "http://www.citect.com/citectscada-batch",
                  "refsource": "CONFIRM",
                  "url": "http://www.citect.com/citectscada-batch"
                },
                {
                  "name": "76937",
                  "refsource": "OSVDB",
                  "url": "http://www.osvdb.org/76937"
                },
                {
                  "name": "http://www.us-cert.gov/control_systems/pdf/ICSA-11-279-02.pdf",
                  "refsource": "MISC",
                  "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-11-279-02.pdf"
                },
                {
                  "name": "46779",
                  "refsource": "SECUNIA",
                  "url": "http://secunia.com/advisories/46779"
                },
                {
                  "name": "1026306",
                  "refsource": "SECTRACK",
                  "url": "http://www.securitytracker.com/id?1026306"
                },
                {
                  "name": "https://my.mitsubishi-automation.com/downloads_show.php?portal_id=1\u0026doc_type=safety\u0026scat=2\u0026sstr=MX4,SCADA",
                  "refsource": "CONFIRM",
                  "url": "https://my.mitsubishi-automation.com/downloads_show.php?portal_id=1\u0026doc_type=safety\u0026scat=2\u0026sstr=MX4,SCADA"
                },
                {
                  "name": "46786",
                  "refsource": "SECUNIA",
                  "url": "http://secunia.com/advisories/46786"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2011-5163",
        "datePublished": "2012-09-15T17:00:00.000Z",
        "dateReserved": "2012-09-15T00:00:00.000Z",
        "dateUpdated": "2024-09-17T00:35:30.905Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }