Search

Find a vulnerability

Search criteria

    7 vulnerabilities by meross

    VAR-202111-0006

    Vulnerability from variot - Updated: 2025-01-30 21:22

    Meross Smart Wi-Fi 2 Way Wall Switch (MSS550X), on its 3.1.3 version and before, creates an open Wi-Fi Access Point without the required security measures in its initial setup. This could allow a remote attacker to obtain the Wi-Fi SSID as well as the password configured by the user from Meross app via Http/JSON plain request

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-202111-0006",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "mss550x",
            "scope": "lte",
            "trust": 1.0,
            "vendor": "meross",
            "version": "3.1.3"
          },
          {
            "model": "mss550x",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "meross",
            "version": null
          },
          {
            "model": "mss550x",
            "scope": "lte",
            "trust": 0.8,
            "vendor": "meross",
            "version": "meross mss550x  firmware  3.1.3  and earlier"
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-014745"
          },
          {
            "db": "NVD",
            "id": "CVE-2021-3774"
          }
        ]
      },
      "cve": "CVE-2021-3774",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "accessComplexity": "MEDIUM",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "nvd@nist.gov",
                "availabilityImpact": "NONE",
                "baseScore": 4.3,
                "confidentialityImpact": "PARTIAL",
                "exploitabilityScore": 8.6,
                "id": "CVE-2021-3774",
                "impactScore": 2.9,
                "integrityImpact": "NONE",
                "severity": "MEDIUM",
                "trust": 1.8,
                "vectorString": "AV:N/AC:M/Au:N/C:P/I:N/A:N",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "nvd@nist.gov",
                "availabilityImpact": "NONE",
                "baseScore": 6.5,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 2.8,
                "id": "CVE-2021-3774",
                "impactScore": 3.6,
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "trust": 1.0,
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:N",
                "version": "3.1"
              },
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "cve-coordination@incibe.es",
                "availabilityImpact": "NONE",
                "baseScore": 7.4,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 2.8,
                "id": "CVE-2021-3774",
                "impactScore": 4.0,
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "CHANGED",
                "trust": 1.0,
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:H/I:N/A:N",
                "version": "3.1"
              },
              {
                "attackComplexity": "Low",
                "attackVector": "Network",
                "author": "NVD",
                "availabilityImpact": "None",
                "baseScore": 6.5,
                "baseSeverity": "Medium",
                "confidentialityImpact": "High",
                "exploitabilityScore": null,
                "id": "CVE-2021-3774",
                "impactScore": null,
                "integrityImpact": "None",
                "privilegesRequired": "None",
                "scope": "Unchanged",
                "trust": 0.8,
                "userInteraction": "Required",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:N",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "nvd@nist.gov",
                "id": "CVE-2021-3774",
                "trust": 1.0,
                "value": "MEDIUM"
              },
              {
                "author": "cve-coordination@incibe.es",
                "id": "CVE-2021-3774",
                "trust": 1.0,
                "value": "HIGH"
              },
              {
                "author": "NVD",
                "id": "CVE-2021-3774",
                "trust": 0.8,
                "value": "Medium"
              },
              {
                "author": "CNNVD",
                "id": "CNNVD-202111-520",
                "trust": 0.6,
                "value": "MEDIUM"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-014745"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202111-520"
          },
          {
            "db": "NVD",
            "id": "CVE-2021-3774"
          },
          {
            "db": "NVD",
            "id": "CVE-2021-3774"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Meross Smart Wi-Fi 2 Way Wall Switch (MSS550X), on its 3.1.3 version and before, creates an open Wi-Fi Access Point without the required security measures in its initial setup. This could allow a remote attacker to obtain the Wi-Fi SSID as well as the password configured by the user from Meross app via Http/JSON plain request",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2021-3774"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-014745"
          }
        ],
        "trust": 1.62
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2021-3774",
            "trust": 3.3
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-014745",
            "trust": 0.8
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202111-520",
            "trust": 0.6
          },
          {
            "db": "OTHER",
            "id": "NONE",
            "trust": 0.1
          }
        ],
        "sources": [
          {
            "db": "OTHER",
            "id": null
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-014745"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202111-520"
          },
          {
            "db": "NVD",
            "id": "CVE-2021-3774"
          }
        ]
      },
      "id": "VAR-202111-0006",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "OTHER",
            "id": null
          }
        ],
        "trust": 0.01
      },
      "iot_taxonomy": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "category": [
              "network device"
            ],
            "sub_category": "switch",
            "trust": 0.1
          }
        ],
        "sources": [
          {
            "db": "OTHER",
            "id": null
          }
        ]
      },
      "last_update_date": "2025-01-30T21:22:44.260000Z",
      "patch": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/patch#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "title": "Top\u00a0Page",
            "trust": 0.8,
            "url": "https://meross.com/home"
          },
          {
            "title": "Meross Smart Wi-Fi 2 Way Wall Switch Security vulnerabilities",
            "trust": 0.6,
            "url": "http://123.124.177.30/web/xxk/bdxqById.tag?id=170223"
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-014745"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202111-520"
          }
        ]
      },
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-319",
            "trust": 1.0
          },
          {
            "problemtype": "Lack of encryption of critical data (CWE-311) [NVD evaluation ]",
            "trust": 0.8
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-014745"
          },
          {
            "db": "NVD",
            "id": "CVE-2021-3774"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 1.4,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2021-3774"
          },
          {
            "trust": 1.4,
            "url": "https://www.incibe-cert.es/en/early-warning/security-advisories/meross-mss550x-missing-encryption-sensitive-data"
          },
          {
            "trust": 1.0,
            "url": "https://www.incibe.es/en/incibe-cert/notices/aviso/meross-mss550x-missing-encryption-sensitive-data"
          },
          {
            "trust": 0.1,
            "url": "https://ieeexplore.ieee.org/abstract/document/10769424"
          }
        ],
        "sources": [
          {
            "db": "OTHER",
            "id": null
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-014745"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202111-520"
          },
          {
            "db": "NVD",
            "id": "CVE-2021-3774"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "OTHER",
            "id": null
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-014745"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202111-520"
          },
          {
            "db": "NVD",
            "id": "CVE-2021-3774"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2022-10-27T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2021-014745"
          },
          {
            "date": "2021-11-05T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-202111-520"
          },
          {
            "date": "2021-11-05T21:15:08.480000",
            "db": "NVD",
            "id": "CVE-2021-3774"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2022-10-27T04:46:00",
            "db": "JVNDB",
            "id": "JVNDB-2021-014745"
          },
          {
            "date": "2022-10-28T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-202111-520"
          },
          {
            "date": "2024-11-21T06:22:23.747000",
            "db": "NVD",
            "id": "CVE-2021-3774"
          }
        ]
      },
      "threat_type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "remote",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202111-520"
          }
        ],
        "trust": 0.6
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Meross\u00a0Smart\u00a0Wi-Fi\u00a02\u00a0Way\u00a0Wall\u00a0Switch\u00a0 Vulnerability regarding lack of encryption of critical data in",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-014745"
          }
        ],
        "trust": 0.8
      },
      "type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "other",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202111-520"
          }
        ],
        "trust": 0.6
      }
    }

    VAR-201805-0261

    Vulnerability from variot - Updated: 2024-11-23 22:59

    Meross MSS110 devices through 1.1.24 contain an unauthenticated admin.htm administrative interface. Meross MSS110 Contains an authentication vulnerability.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. Meross MSS110 is a smart WiFi socket device produced by China Meross Technology Company. There are security vulnerabilities in Meross MSS110 1.1.24 and earlier versions. An attacker could exploit this vulnerability to cause a denial of service or obtain information

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-201805-0261",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "mss110",
            "scope": "lte",
            "trust": 1.8,
            "vendor": "meross",
            "version": "1.1.24"
          },
          {
            "model": "mss110",
            "scope": "eq",
            "trust": 0.6,
            "vendor": "meross",
            "version": "1.1.24"
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-004938"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201805-130"
          },
          {
            "db": "NVD",
            "id": "CVE-2018-10544"
          }
        ]
      },
      "configurations": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/configurations#",
          "children": {
            "@container": "@list"
          },
          "cpe_match": {
            "@container": "@list"
          },
          "data": {
            "@container": "@list"
          },
          "nodes": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "CVE_data_version": "4.0",
            "nodes": [
              {
                "cpe_match": [
                  {
                    "cpe22Uri": "cpe:/o:meross:mss110_firmware",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-004938"
          }
        ]
      },
      "cve": "CVE-2018-10544",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "nvd@nist.gov",
                "availabilityImpact": "NONE",
                "baseScore": 5.0,
                "confidentialityImpact": "PARTIAL",
                "exploitabilityScore": 10.0,
                "id": "CVE-2018-10544",
                "impactScore": 2.9,
                "integrityImpact": "NONE",
                "severity": "MEDIUM",
                "trust": 1.8,
                "vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N",
                "version": "2.0"
              },
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "VULHUB",
                "availabilityImpact": "NONE",
                "baseScore": 5.0,
                "confidentialityImpact": "PARTIAL",
                "exploitabilityScore": 10.0,
                "id": "VHN-120314",
                "impactScore": 2.9,
                "integrityImpact": "NONE",
                "severity": "MEDIUM",
                "trust": 0.1,
                "vectorString": "AV:N/AC:L/AU:N/C:P/I:N/A:N",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "nvd@nist.gov",
                "availabilityImpact": "HIGH",
                "baseScore": 9.8,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 3.9,
                "id": "CVE-2018-10544",
                "impactScore": 5.9,
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "trust": 1.8,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "nvd@nist.gov",
                "id": "CVE-2018-10544",
                "trust": 1.0,
                "value": "CRITICAL"
              },
              {
                "author": "NVD",
                "id": "CVE-2018-10544",
                "trust": 0.8,
                "value": "Critical"
              },
              {
                "author": "CNNVD",
                "id": "CNNVD-201805-130",
                "trust": 0.6,
                "value": "MEDIUM"
              },
              {
                "author": "VULHUB",
                "id": "VHN-120314",
                "trust": 0.1,
                "value": "MEDIUM"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "VULHUB",
            "id": "VHN-120314"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-004938"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201805-130"
          },
          {
            "db": "NVD",
            "id": "CVE-2018-10544"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Meross MSS110 devices through 1.1.24 contain an unauthenticated admin.htm administrative interface. Meross MSS110 Contains an authentication vulnerability.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. Meross MSS110 is a smart WiFi socket device produced by China Meross Technology Company. There are security vulnerabilities in Meross MSS110 1.1.24 and earlier versions. An attacker could exploit this vulnerability to cause a denial of service or obtain information",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2018-10544"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-004938"
          },
          {
            "db": "VULHUB",
            "id": "VHN-120314"
          }
        ],
        "trust": 1.71
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2018-10544",
            "trust": 2.5
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-004938",
            "trust": 0.8
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201805-130",
            "trust": 0.7
          },
          {
            "db": "VULHUB",
            "id": "VHN-120314",
            "trust": 0.1
          }
        ],
        "sources": [
          {
            "db": "VULHUB",
            "id": "VHN-120314"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-004938"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201805-130"
          },
          {
            "db": "NVD",
            "id": "CVE-2018-10544"
          }
        ]
      },
      "id": "VAR-201805-0261",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "VULHUB",
            "id": "VHN-120314"
          }
        ],
        "trust": 0.6714285999999999
      },
      "last_update_date": "2024-11-23T22:59:00.081000Z",
      "patch": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/patch#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "title": "Smart WiFi Plug Mini",
            "trust": 0.8,
            "url": "http://meross.com/products/home_automation/smart_wi_fi_plug/12.html"
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-004938"
          }
        ]
      },
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-287",
            "trust": 1.9
          }
        ],
        "sources": [
          {
            "db": "VULHUB",
            "id": "VHN-120314"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-004938"
          },
          {
            "db": "NVD",
            "id": "CVE-2018-10544"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 2.5,
            "url": "https://garrettmiller.github.io/meross-mss110-vuln/"
          },
          {
            "trust": 0.8,
            "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2018-10544"
          },
          {
            "trust": 0.8,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2018-10544"
          }
        ],
        "sources": [
          {
            "db": "VULHUB",
            "id": "VHN-120314"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-004938"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201805-130"
          },
          {
            "db": "NVD",
            "id": "CVE-2018-10544"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "VULHUB",
            "id": "VHN-120314"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-004938"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201805-130"
          },
          {
            "db": "NVD",
            "id": "CVE-2018-10544"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2018-05-02T00:00:00",
            "db": "VULHUB",
            "id": "VHN-120314"
          },
          {
            "date": "2018-07-02T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2018-004938"
          },
          {
            "date": "2018-05-03T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-201805-130"
          },
          {
            "date": "2018-05-02T07:29:00.243000",
            "db": "NVD",
            "id": "CVE-2018-10544"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2018-06-13T00:00:00",
            "db": "VULHUB",
            "id": "VHN-120314"
          },
          {
            "date": "2018-07-02T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2018-004938"
          },
          {
            "date": "2018-05-03T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-201805-130"
          },
          {
            "date": "2024-11-21T03:41:31.900000",
            "db": "NVD",
            "id": "CVE-2018-10544"
          }
        ]
      },
      "threat_type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "remote",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-201805-130"
          }
        ],
        "trust": 0.6
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Meross MSS110 Authentication vulnerability",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-004938"
          }
        ],
        "trust": 0.8
      },
      "type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "authorization issue",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-201805-130"
          }
        ],
        "trust": 0.6
      }
    }

    VAR-201805-0891

    Vulnerability from variot - Updated: 2024-11-23 22:45

    Meross MSS110 devices before 1.1.24 contain a TELNET listener providing access for an undocumented admin account with a blank password. Meross MSS110 Contains a vulnerability in the use of hard-coded credentials.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. MerossMSS110 is a smart WiFi socket device from China's Meross Technology. One of the TELNET listener components of TELNETlistenerhi. A security vulnerability exists in the TELNETlistener in versions prior to MerossMSS1101.1.24

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-201805-0891",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "mss110",
            "scope": "lt",
            "trust": 1.4,
            "vendor": "meross",
            "version": "1.1.24"
          },
          {
            "model": "mss110",
            "scope": "lte",
            "trust": 1.0,
            "vendor": "meross",
            "version": "1.1.24"
          },
          {
            "model": "mss110",
            "scope": "eq",
            "trust": 0.6,
            "vendor": "meross",
            "version": "1.1.24"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2018-09217"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-004942"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201805-125"
          },
          {
            "db": "NVD",
            "id": "CVE-2018-6401"
          }
        ]
      },
      "configurations": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/configurations#",
          "children": {
            "@container": "@list"
          },
          "cpe_match": {
            "@container": "@list"
          },
          "data": {
            "@container": "@list"
          },
          "nodes": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "CVE_data_version": "4.0",
            "nodes": [
              {
                "cpe_match": [
                  {
                    "cpe22Uri": "cpe:/o:meross:mss110_firmware",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-004942"
          }
        ]
      },
      "cve": "CVE-2018-6401",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "nvd@nist.gov",
                "availabilityImpact": "PARTIAL",
                "baseScore": 7.5,
                "confidentialityImpact": "PARTIAL",
                "exploitabilityScore": 10.0,
                "id": "CVE-2018-6401",
                "impactScore": 6.4,
                "integrityImpact": "PARTIAL",
                "severity": "HIGH",
                "trust": 1.8,
                "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
                "version": "2.0"
              },
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "CNVD",
                "availabilityImpact": "NONE",
                "baseScore": 5.0,
                "confidentialityImpact": "PARTIAL",
                "exploitabilityScore": 10.0,
                "id": "CNVD-2018-09217",
                "impactScore": 2.9,
                "integrityImpact": "NONE",
                "severity": "MEDIUM",
                "trust": 0.6,
                "vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N",
                "version": "2.0"
              },
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "VULHUB",
                "availabilityImpact": "PARTIAL",
                "baseScore": 7.5,
                "confidentialityImpact": "PARTIAL",
                "exploitabilityScore": 10.0,
                "id": "VHN-136433",
                "impactScore": 6.4,
                "integrityImpact": "PARTIAL",
                "severity": "HIGH",
                "trust": 0.1,
                "vectorString": "AV:N/AC:L/AU:N/C:P/I:P/A:P",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "nvd@nist.gov",
                "availabilityImpact": "HIGH",
                "baseScore": 9.8,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 3.9,
                "id": "CVE-2018-6401",
                "impactScore": 5.9,
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "trust": 1.8,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "nvd@nist.gov",
                "id": "CVE-2018-6401",
                "trust": 1.0,
                "value": "CRITICAL"
              },
              {
                "author": "NVD",
                "id": "CVE-2018-6401",
                "trust": 0.8,
                "value": "Critical"
              },
              {
                "author": "CNVD",
                "id": "CNVD-2018-09217",
                "trust": 0.6,
                "value": "MEDIUM"
              },
              {
                "author": "CNNVD",
                "id": "CNNVD-201805-125",
                "trust": 0.6,
                "value": "HIGH"
              },
              {
                "author": "VULHUB",
                "id": "VHN-136433",
                "trust": 0.1,
                "value": "HIGH"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2018-09217"
          },
          {
            "db": "VULHUB",
            "id": "VHN-136433"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-004942"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201805-125"
          },
          {
            "db": "NVD",
            "id": "CVE-2018-6401"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Meross MSS110 devices before 1.1.24 contain a TELNET listener providing access for an undocumented admin account with a blank password. Meross MSS110 Contains a vulnerability in the use of hard-coded credentials.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. MerossMSS110 is a smart WiFi socket device from China\u0027s Meross Technology. One of the TELNET listener components of TELNETlistenerhi. A security vulnerability exists in the TELNETlistener in versions prior to MerossMSS1101.1.24",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2018-6401"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-004942"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2018-09217"
          },
          {
            "db": "VULHUB",
            "id": "VHN-136433"
          }
        ],
        "trust": 2.25
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2018-6401",
            "trust": 3.1
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-004942",
            "trust": 0.8
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201805-125",
            "trust": 0.7
          },
          {
            "db": "CNVD",
            "id": "CNVD-2018-09217",
            "trust": 0.6
          },
          {
            "db": "VULHUB",
            "id": "VHN-136433",
            "trust": 0.1
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2018-09217"
          },
          {
            "db": "VULHUB",
            "id": "VHN-136433"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-004942"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201805-125"
          },
          {
            "db": "NVD",
            "id": "CVE-2018-6401"
          }
        ]
      },
      "id": "VAR-201805-0891",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2018-09217"
          },
          {
            "db": "VULHUB",
            "id": "VHN-136433"
          }
        ],
        "trust": 1.2714286
      },
      "iot_taxonomy": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "category": [
              "Network device"
            ],
            "sub_category": null,
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2018-09217"
          }
        ]
      },
      "last_update_date": "2024-11-23T22:45:18.948000Z",
      "patch": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/patch#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "title": "Smart WiFi Plug Mini",
            "trust": 0.8,
            "url": "http://meross.com/products/home_automation/smart_wi_fi_plug/12.html"
          },
          {
            "title": "MerossMSS110TELNETlistener is not authorized to access the patch for the vulnerability",
            "trust": 0.6,
            "url": "https://www.cnvd.org.cn/patchInfo/show/128585"
          },
          {
            "title": "Meross MSS110 TELNET listener Security vulnerabilities",
            "trust": 0.6,
            "url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=79858"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2018-09217"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-004942"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201805-125"
          }
        ]
      },
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-798",
            "trust": 1.9
          }
        ],
        "sources": [
          {
            "db": "VULHUB",
            "id": "VHN-136433"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-004942"
          },
          {
            "db": "NVD",
            "id": "CVE-2018-6401"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 3.1,
            "url": "https://garrettmiller.github.io/meross-mss110-vuln/"
          },
          {
            "trust": 0.8,
            "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2018-6401"
          },
          {
            "trust": 0.8,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2018-6401"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2018-09217"
          },
          {
            "db": "VULHUB",
            "id": "VHN-136433"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-004942"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201805-125"
          },
          {
            "db": "NVD",
            "id": "CVE-2018-6401"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "CNVD",
            "id": "CNVD-2018-09217"
          },
          {
            "db": "VULHUB",
            "id": "VHN-136433"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-004942"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201805-125"
          },
          {
            "db": "NVD",
            "id": "CVE-2018-6401"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2018-05-10T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2018-09217"
          },
          {
            "date": "2018-05-02T00:00:00",
            "db": "VULHUB",
            "id": "VHN-136433"
          },
          {
            "date": "2018-07-02T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2018-004942"
          },
          {
            "date": "2018-05-03T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-201805-125"
          },
          {
            "date": "2018-05-02T07:29:00.570000",
            "db": "NVD",
            "id": "CVE-2018-6401"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2018-05-10T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2018-09217"
          },
          {
            "date": "2018-06-13T00:00:00",
            "db": "VULHUB",
            "id": "VHN-136433"
          },
          {
            "date": "2018-07-02T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2018-004942"
          },
          {
            "date": "2018-05-03T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-201805-125"
          },
          {
            "date": "2024-11-21T04:10:38.533000",
            "db": "NVD",
            "id": "CVE-2018-6401"
          }
        ]
      },
      "threat_type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "remote",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-201805-125"
          }
        ],
        "trust": 0.6
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Meross MSS110 Vulnerabilities related to the use of hard-coded credentials",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-004942"
          }
        ],
        "trust": 0.8
      },
      "type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "lack of information",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-201805-125"
          }
        ],
        "trust": 0.6
      }
    }

    CVE-2023-46892 (GCVE-0-2023-46892)

    Vulnerability from nvd – Published: 2024-01-23 00:00 – Updated: 2025-06-17 16:12
    VLAI
    Summary
    The radio frequency communication protocol being used by Meross MSH30Q 4.5.23 is vulnerable to replay attacks, allowing attackers to record and replay previously captured communication to execute unauthorized commands or actions (e.g., thermostat's temperature).
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2024-08-27 15:25 UTC
    CWE
    • n/a
    • CWE-294 - Authentication Bypass by Capture-replay
    Impacted products
    Vendor Product Version
    meross msh30q Affected: 4.5.23
        cpe:2.3:h:meross:msh30q:-:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T20:53:21.944Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.kth.se/cs/nse/research/software-systems-architecture-and-security/projects/ethical-hacking-1.1279219"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "affected": [
              {
                "cpes": [
                  "cpe:2.3:h:meross:msh30q:-:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "msh30q",
                "vendor": "meross",
                "versions": [
                  {
                    "status": "affected",
                    "version": "4.5.23"
                  }
                ]
              }
            ],
            "metrics": [
              {
                "cvssV3_1": {
                  "attackComplexity": "LOW",
                  "attackVector": "ADJACENT_NETWORK",
                  "availabilityImpact": "HIGH",
                  "baseScore": 8.8,
                  "baseSeverity": "HIGH",
                  "confidentialityImpact": "HIGH",
                  "integrityImpact": "HIGH",
                  "privilegesRequired": "NONE",
                  "scope": "UNCHANGED",
                  "userInteraction": "NONE",
                  "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                  "version": "3.1"
                }
              },
              {
                "other": {
                  "content": {
                    "id": "CVE-2023-46892",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-08-27T15:25:00.657667Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "problemTypes": [
              {
                "descriptions": [
                  {
                    "cweId": "CWE-294",
                    "description": "CWE-294 Authentication Bypass by Capture-replay",
                    "lang": "en",
                    "type": "CWE"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-06-17T16:12:41.604Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "The radio frequency communication protocol being used by Meross MSH30Q 4.5.23 is vulnerable to replay attacks, allowing attackers to record and replay previously captured communication to execute unauthorized commands or actions (e.g., thermostat\u0027s temperature)."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-01-23T20:14:50.304Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "url": "https://www.kth.se/cs/nse/research/software-systems-architecture-and-security/projects/ethical-hacking-1.1279219"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2023-46892",
        "datePublished": "2024-01-23T00:00:00.000Z",
        "dateReserved": "2023-10-30T00:00:00.000Z",
        "dateUpdated": "2025-06-17T16:12:41.604Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2021-3774 (GCVE-0-2021-3774)

    Vulnerability from nvd – Published: 2021-11-05 19:41 – Updated: 2025-04-23 19:24
    VLAI
    Title
    Meross MSS550X Missing Encryption of Sensitive Data
    Summary
    Meross Smart Wi-Fi 2 Way Wall Switch (MSS550X), on its 3.1.3 version and before, creates an open Wi-Fi Access Point without the required security measures in its initial setup. This could allow a remote attacker to obtain the Wi-Fi SSID as well as the password configured by the user from Meross app via Http/JSON plain request.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2025-04-23 13:10 UTC
    CWE
    • CWE-319 - Cleartext Transmission of Sensitive Information
    References
    Impacted products
    Vendor Product Version
    Meross Meross Smart Wi-Fi 2 Way Wall Switch Affected: 0 , ≤ 3.1.3 (custom)
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T17:09:09.214Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://www.incibe.es/en/incibe-cert/notices/aviso/meross-mss550x-missing-encryption-sensitive-data"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2021-3774",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-04-23T13:10:15.464816Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-04-23T19:24:23.318Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "Meross Smart Wi-Fi 2 Way Wall Switch",
              "vendor": "Meross",
              "versions": [
                {
                  "lessThanOrEqual": "3.1.3",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "user": "00000000-0000-4000-9000-000000000000",
              "value": "Gerard Fuguet Morales"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Meross Smart Wi-Fi 2 Way Wall Switch (MSS550X), on its 3.1.3 version and before, creates an open Wi-Fi Access Point without the required security measures in its initial setup. This could allow a remote attacker to obtain the Wi-Fi SSID as well as the password configured by the user from Meross app via Http/JSON plain request."
                }
              ],
              "value": "Meross Smart Wi-Fi 2 Way Wall Switch (MSS550X), on its 3.1.3 version and before, creates an open Wi-Fi Access Point without the required security measures in its initial setup. This could allow a remote attacker to obtain the Wi-Fi SSID as well as the password configured by the user from Meross app via Http/JSON plain request."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "NONE",
                "baseScore": 7.4,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "CHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:H/I:N/A:N",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-319",
                  "description": "CWE-319 Cleartext Transmission of Sensitive Information",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2023-11-20T13:37:54.806Z",
            "orgId": "0cbda920-cd7f-484a-8e76-bf7f4b7f4516",
            "shortName": "INCIBE"
          },
          "references": [
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://www.incibe.es/en/incibe-cert/notices/aviso/meross-mss550x-missing-encryption-sensitive-data"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "This vulnerability has been solved by Meross in MSS550X version 3.2.3."
                }
              ],
              "value": "This vulnerability has been solved by Meross in MSS550X version 3.2.3."
            }
          ],
          "source": {
            "advisory": "INCIBE-2021-0451",
            "discovery": "EXTERNAL"
          },
          "title": "Meross MSS550X Missing Encryption of Sensitive Data",
          "x_generator": {
            "engine": "Vulnogram 0.0.9"
          },
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cve-coordination@incibe.es",
              "ID": "CVE-2021-3774",
              "STATE": "PUBLIC",
              "TITLE": "Meross MSS550X Missing Encryption of Sensitive Data"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "Meross Smart Wi-Fi 2 Way Wall Switch",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003c=",
                                "version_name": "3.1.3",
                                "version_value": "3.1.3"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "Meross"
                  }
                ]
              }
            },
            "credit": [
              {
                "lang": "eng",
                "value": "Gerard Fuguet Morales"
              }
            ],
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Meross Smart Wi-Fi 2 Way Wall Switch (MSS550X), on its 3.1.3 version and before, creates an open Wi-Fi Access Point without the required security measures in its initial setup. This could allow a remote attacker to obtain the Wi-Fi SSID as well as the password configured by the user from Meross app via Http/JSON plain request."
                }
              ]
            },
            "generator": {
              "engine": "Vulnogram 0.0.9"
            },
            "impact": {
              "cvss": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "NONE",
                "baseScore": 9.3,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "CHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:H/I:H/A:N",
                "version": "3.1"
              }
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-311: Missing Encryption of Sensitive Data"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.incibe-cert.es/en/early-warning/security-advisories/meross-mss550x-missing-encryption-sensitive-data",
                  "refsource": "CONFIRM",
                  "url": "https://www.incibe-cert.es/en/early-warning/security-advisories/meross-mss550x-missing-encryption-sensitive-data"
                }
              ]
            },
            "solution": [
              {
                "lang": "en",
                "value": "This vulnerability has been solved by Meross in MSS550X version 3.2.3"
              }
            ],
            "source": {
              "advisory": "INCIBE-2021-0451",
              "discovery": "EXTERNAL"
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "0cbda920-cd7f-484a-8e76-bf7f4b7f4516",
        "assignerShortName": "INCIBE",
        "cveId": "CVE-2021-3774",
        "datePublished": "2021-11-05T19:41:27.000Z",
        "dateReserved": "2021-09-06T00:00:00.000Z",
        "dateUpdated": "2025-04-23T19:24:23.318Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2023-46892 (GCVE-0-2023-46892)

    Vulnerability from cvelistv5 – Published: 2024-01-23 00:00 – Updated: 2025-06-17 16:12
    VLAI
    Summary
    The radio frequency communication protocol being used by Meross MSH30Q 4.5.23 is vulnerable to replay attacks, allowing attackers to record and replay previously captured communication to execute unauthorized commands or actions (e.g., thermostat's temperature).
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2024-08-27 15:25 UTC
    CWE
    • n/a
    • CWE-294 - Authentication Bypass by Capture-replay
    Impacted products
    Vendor Product Version
    meross msh30q Affected: 4.5.23
        cpe:2.3:h:meross:msh30q:-:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T20:53:21.944Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.kth.se/cs/nse/research/software-systems-architecture-and-security/projects/ethical-hacking-1.1279219"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "affected": [
              {
                "cpes": [
                  "cpe:2.3:h:meross:msh30q:-:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "msh30q",
                "vendor": "meross",
                "versions": [
                  {
                    "status": "affected",
                    "version": "4.5.23"
                  }
                ]
              }
            ],
            "metrics": [
              {
                "cvssV3_1": {
                  "attackComplexity": "LOW",
                  "attackVector": "ADJACENT_NETWORK",
                  "availabilityImpact": "HIGH",
                  "baseScore": 8.8,
                  "baseSeverity": "HIGH",
                  "confidentialityImpact": "HIGH",
                  "integrityImpact": "HIGH",
                  "privilegesRequired": "NONE",
                  "scope": "UNCHANGED",
                  "userInteraction": "NONE",
                  "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                  "version": "3.1"
                }
              },
              {
                "other": {
                  "content": {
                    "id": "CVE-2023-46892",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-08-27T15:25:00.657667Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "problemTypes": [
              {
                "descriptions": [
                  {
                    "cweId": "CWE-294",
                    "description": "CWE-294 Authentication Bypass by Capture-replay",
                    "lang": "en",
                    "type": "CWE"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-06-17T16:12:41.604Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "The radio frequency communication protocol being used by Meross MSH30Q 4.5.23 is vulnerable to replay attacks, allowing attackers to record and replay previously captured communication to execute unauthorized commands or actions (e.g., thermostat\u0027s temperature)."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-01-23T20:14:50.304Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "url": "https://www.kth.se/cs/nse/research/software-systems-architecture-and-security/projects/ethical-hacking-1.1279219"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2023-46892",
        "datePublished": "2024-01-23T00:00:00.000Z",
        "dateReserved": "2023-10-30T00:00:00.000Z",
        "dateUpdated": "2025-06-17T16:12:41.604Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2021-3774 (GCVE-0-2021-3774)

    Vulnerability from cvelistv5 – Published: 2021-11-05 19:41 – Updated: 2025-04-23 19:24
    VLAI
    Title
    Meross MSS550X Missing Encryption of Sensitive Data
    Summary
    Meross Smart Wi-Fi 2 Way Wall Switch (MSS550X), on its 3.1.3 version and before, creates an open Wi-Fi Access Point without the required security measures in its initial setup. This could allow a remote attacker to obtain the Wi-Fi SSID as well as the password configured by the user from Meross app via Http/JSON plain request.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2025-04-23 13:10 UTC
    CWE
    • CWE-319 - Cleartext Transmission of Sensitive Information
    References
    Impacted products
    Vendor Product Version
    Meross Meross Smart Wi-Fi 2 Way Wall Switch Affected: 0 , ≤ 3.1.3 (custom)
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T17:09:09.214Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://www.incibe.es/en/incibe-cert/notices/aviso/meross-mss550x-missing-encryption-sensitive-data"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2021-3774",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-04-23T13:10:15.464816Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-04-23T19:24:23.318Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "Meross Smart Wi-Fi 2 Way Wall Switch",
              "vendor": "Meross",
              "versions": [
                {
                  "lessThanOrEqual": "3.1.3",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "user": "00000000-0000-4000-9000-000000000000",
              "value": "Gerard Fuguet Morales"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Meross Smart Wi-Fi 2 Way Wall Switch (MSS550X), on its 3.1.3 version and before, creates an open Wi-Fi Access Point without the required security measures in its initial setup. This could allow a remote attacker to obtain the Wi-Fi SSID as well as the password configured by the user from Meross app via Http/JSON plain request."
                }
              ],
              "value": "Meross Smart Wi-Fi 2 Way Wall Switch (MSS550X), on its 3.1.3 version and before, creates an open Wi-Fi Access Point without the required security measures in its initial setup. This could allow a remote attacker to obtain the Wi-Fi SSID as well as the password configured by the user from Meross app via Http/JSON plain request."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "NONE",
                "baseScore": 7.4,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "CHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:H/I:N/A:N",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-319",
                  "description": "CWE-319 Cleartext Transmission of Sensitive Information",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2023-11-20T13:37:54.806Z",
            "orgId": "0cbda920-cd7f-484a-8e76-bf7f4b7f4516",
            "shortName": "INCIBE"
          },
          "references": [
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://www.incibe.es/en/incibe-cert/notices/aviso/meross-mss550x-missing-encryption-sensitive-data"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "This vulnerability has been solved by Meross in MSS550X version 3.2.3."
                }
              ],
              "value": "This vulnerability has been solved by Meross in MSS550X version 3.2.3."
            }
          ],
          "source": {
            "advisory": "INCIBE-2021-0451",
            "discovery": "EXTERNAL"
          },
          "title": "Meross MSS550X Missing Encryption of Sensitive Data",
          "x_generator": {
            "engine": "Vulnogram 0.0.9"
          },
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cve-coordination@incibe.es",
              "ID": "CVE-2021-3774",
              "STATE": "PUBLIC",
              "TITLE": "Meross MSS550X Missing Encryption of Sensitive Data"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "Meross Smart Wi-Fi 2 Way Wall Switch",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003c=",
                                "version_name": "3.1.3",
                                "version_value": "3.1.3"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "Meross"
                  }
                ]
              }
            },
            "credit": [
              {
                "lang": "eng",
                "value": "Gerard Fuguet Morales"
              }
            ],
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Meross Smart Wi-Fi 2 Way Wall Switch (MSS550X), on its 3.1.3 version and before, creates an open Wi-Fi Access Point without the required security measures in its initial setup. This could allow a remote attacker to obtain the Wi-Fi SSID as well as the password configured by the user from Meross app via Http/JSON plain request."
                }
              ]
            },
            "generator": {
              "engine": "Vulnogram 0.0.9"
            },
            "impact": {
              "cvss": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "NONE",
                "baseScore": 9.3,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "CHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:H/I:H/A:N",
                "version": "3.1"
              }
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-311: Missing Encryption of Sensitive Data"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.incibe-cert.es/en/early-warning/security-advisories/meross-mss550x-missing-encryption-sensitive-data",
                  "refsource": "CONFIRM",
                  "url": "https://www.incibe-cert.es/en/early-warning/security-advisories/meross-mss550x-missing-encryption-sensitive-data"
                }
              ]
            },
            "solution": [
              {
                "lang": "en",
                "value": "This vulnerability has been solved by Meross in MSS550X version 3.2.3"
              }
            ],
            "source": {
              "advisory": "INCIBE-2021-0451",
              "discovery": "EXTERNAL"
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "0cbda920-cd7f-484a-8e76-bf7f4b7f4516",
        "assignerShortName": "INCIBE",
        "cveId": "CVE-2021-3774",
        "datePublished": "2021-11-05T19:41:27.000Z",
        "dateReserved": "2021-09-06T00:00:00.000Z",
        "dateUpdated": "2025-04-23T19:24:23.318Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }