    CVE-2024-48544 (GCVE-0-2024-48544)

    Vulnerability from nvd – Published: 2024-10-24 00:00 – Updated: 2026-07-05 00:49
    VLAI
    Summary
    Incorrect access control in the firmware update and download processes of Sylvania Smart Home v3.0.3 allows attackers to access sensitive information by analyzing the code and data within the APK file.
    SSVC
    Exploitation: poc Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2024-10-24 20:58 UTC
    CWE
    • n/a
    • CWE-863 - Incorrect Authorization
    Assigner
    mitre CNA under the mitre root
    CNA scorecard E 28/100 over 2325 records in the last 180 days details
    Impacted products
    Vendor Product Version
    ledvance sylvania_smart_home_firmware Affected: 3.0.3
        cpe:2.3:o:ledvance:sylvania_smart_home_firmware:3.0.3:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "affected": [
              {
                "cpes": [
                  "cpe:2.3:o:ledvance:sylvania_smart_home_firmware:3.0.3:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "sylvania_smart_home_firmware",
                "vendor": "ledvance",
                "versions": [
                  {
                    "status": "affected",
                    "version": "3.0.3"
                  }
                ]
              }
            ],
            "metrics": [
              {
                "cvssV3_1": {
                  "attackComplexity": "LOW",
                  "attackVector": "LOCAL",
                  "availabilityImpact": "HIGH",
                  "baseScore": 8.4,
                  "baseSeverity": "HIGH",
                  "confidentialityImpact": "HIGH",
                  "integrityImpact": "HIGH",
                  "privilegesRequired": "NONE",
                  "scope": "UNCHANGED",
                  "userInteraction": "NONE",
                  "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                  "version": "3.1"
                }
              },
              {
                "other": {
                  "content": {
                    "id": "CVE-2024-48544",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-10-24T20:58:14.887887Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "problemTypes": [
              {
                "descriptions": [
                  {
                    "cweId": "CWE-863",
                    "description": "CWE-863 Incorrect Authorization",
                    "lang": "en",
                    "type": "CWE"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-10-24T21:01:12.948Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Incorrect access control in the firmware update and download processes of Sylvania Smart Home v3.0.3 allows attackers to access sensitive information by analyzing the code and data within the APK file."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-07-05T00:49:13.486Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "url": "https://github.com/HankJames/Vul-Reports/blob/main/FirmwareLeakage/com.ledvance.smartplus/com.ledvance.smartplus.md"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2024-48544",
        "datePublished": "2024-10-24T00:00:00.000Z",
        "dateReserved": "2024-10-08T00:00:00.000Z",
        "dateUpdated": "2026-07-05T00:49:13.486Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2024-48777 (GCVE-0-2024-48777)

    Vulnerability from nvd – Published: 2024-10-11 00:00 – Updated: 2026-07-05 16:04
    VLAI
    Summary
    LEDVANCE com.ledvance.smartplus.eu 2.1.10 allows a remote attacker to obtain sensitive information via the firmware update process.
    SSVC
    Exploitation: poc Automatable: yes Technical Impact: partial
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2024-10-15 18:27 UTC
    CWE
    • n/a
    • CWE-306 - Missing Authentication for Critical Function
    Assigner
    mitre CNA under the mitre root
    CNA scorecard E 28/100 over 2325 records in the last 180 days details
    Impacted products
    Vendor Product Version
    ledvance smartplus_firmware Affected: 2.1.10
        cpe:2.3:o:ledvance:smartplus_firmware:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "affected": [
              {
                "cpes": [
                  "cpe:2.3:o:ledvance:smartplus_firmware:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "smartplus_firmware",
                "vendor": "ledvance",
                "versions": [
                  {
                    "status": "affected",
                    "version": "2.1.10"
                  }
                ]
              }
            ],
            "metrics": [
              {
                "cvssV3_1": {
                  "attackComplexity": "LOW",
                  "attackVector": "NETWORK",
                  "availabilityImpact": "NONE",
                  "baseScore": 7.5,
                  "baseSeverity": "HIGH",
                  "confidentialityImpact": "HIGH",
                  "integrityImpact": "NONE",
                  "privilegesRequired": "NONE",
                  "scope": "UNCHANGED",
                  "userInteraction": "NONE",
                  "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
                  "version": "3.1"
                }
              },
              {
                "other": {
                  "content": {
                    "id": "CVE-2024-48777",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-10-15T18:27:07.729500Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "problemTypes": [
              {
                "descriptions": [
                  {
                    "cweId": "CWE-306",
                    "description": "CWE-306 Missing Authentication for Critical Function",
                    "lang": "en",
                    "type": "CWE"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-10-15T18:43:15.758Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "LEDVANCE com.ledvance.smartplus.eu 2.1.10 allows a remote attacker to obtain sensitive information via the firmware update process."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-07-05T16:04:46.092Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "url": "https://github.com/HankJames/Vul-Reports/blob/main/FirmwareLeakage/com.ledvance.smartplus.eu/com.ledvance.smartplus.eu.md"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2024-48777",
        "datePublished": "2024-10-11T00:00:00.000Z",
        "dateReserved": "2024-10-08T00:00:00.000Z",
        "dateUpdated": "2026-07-05T16:04:46.092Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2024-48544 (GCVE-0-2024-48544)

    Vulnerability from cvelistv5 – Published: 2024-10-24 00:00 – Updated: 2026-07-05 00:49
    VLAI
    Summary
    Incorrect access control in the firmware update and download processes of Sylvania Smart Home v3.0.3 allows attackers to access sensitive information by analyzing the code and data within the APK file.
    SSVC
    Exploitation: poc Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2024-10-24 20:58 UTC
    CWE
    • n/a
    • CWE-863 - Incorrect Authorization
    Assigner
    mitre CNA under the mitre root
    CNA scorecard E 28/100 over 2325 records in the last 180 days details
    Impacted products
    Vendor Product Version
    ledvance sylvania_smart_home_firmware Affected: 3.0.3
        cpe:2.3:o:ledvance:sylvania_smart_home_firmware:3.0.3:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "affected": [
              {
                "cpes": [
                  "cpe:2.3:o:ledvance:sylvania_smart_home_firmware:3.0.3:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "sylvania_smart_home_firmware",
                "vendor": "ledvance",
                "versions": [
                  {
                    "status": "affected",
                    "version": "3.0.3"
                  }
                ]
              }
            ],
            "metrics": [
              {
                "cvssV3_1": {
                  "attackComplexity": "LOW",
                  "attackVector": "LOCAL",
                  "availabilityImpact": "HIGH",
                  "baseScore": 8.4,
                  "baseSeverity": "HIGH",
                  "confidentialityImpact": "HIGH",
                  "integrityImpact": "HIGH",
                  "privilegesRequired": "NONE",
                  "scope": "UNCHANGED",
                  "userInteraction": "NONE",
                  "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                  "version": "3.1"
                }
              },
              {
                "other": {
                  "content": {
                    "id": "CVE-2024-48544",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-10-24T20:58:14.887887Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "problemTypes": [
              {
                "descriptions": [
                  {
                    "cweId": "CWE-863",
                    "description": "CWE-863 Incorrect Authorization",
                    "lang": "en",
                    "type": "CWE"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-10-24T21:01:12.948Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Incorrect access control in the firmware update and download processes of Sylvania Smart Home v3.0.3 allows attackers to access sensitive information by analyzing the code and data within the APK file."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-07-05T00:49:13.486Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "url": "https://github.com/HankJames/Vul-Reports/blob/main/FirmwareLeakage/com.ledvance.smartplus/com.ledvance.smartplus.md"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2024-48544",
        "datePublished": "2024-10-24T00:00:00.000Z",
        "dateReserved": "2024-10-08T00:00:00.000Z",
        "dateUpdated": "2026-07-05T00:49:13.486Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2024-48777 (GCVE-0-2024-48777)

    Vulnerability from cvelistv5 – Published: 2024-10-11 00:00 – Updated: 2026-07-05 16:04
    VLAI
    Summary
    LEDVANCE com.ledvance.smartplus.eu 2.1.10 allows a remote attacker to obtain sensitive information via the firmware update process.
    SSVC
    Exploitation: poc Automatable: yes Technical Impact: partial
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2024-10-15 18:27 UTC
    CWE
    • n/a
    • CWE-306 - Missing Authentication for Critical Function
    Assigner
    mitre CNA under the mitre root
    CNA scorecard E 28/100 over 2325 records in the last 180 days details
    Impacted products
    Vendor Product Version
    ledvance smartplus_firmware Affected: 2.1.10
        cpe:2.3:o:ledvance:smartplus_firmware:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "affected": [
              {
                "cpes": [
                  "cpe:2.3:o:ledvance:smartplus_firmware:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "smartplus_firmware",
                "vendor": "ledvance",
                "versions": [
                  {
                    "status": "affected",
                    "version": "2.1.10"
                  }
                ]
              }
            ],
            "metrics": [
              {
                "cvssV3_1": {
                  "attackComplexity": "LOW",
                  "attackVector": "NETWORK",
                  "availabilityImpact": "NONE",
                  "baseScore": 7.5,
                  "baseSeverity": "HIGH",
                  "confidentialityImpact": "HIGH",
                  "integrityImpact": "NONE",
                  "privilegesRequired": "NONE",
                  "scope": "UNCHANGED",
                  "userInteraction": "NONE",
                  "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
                  "version": "3.1"
                }
              },
              {
                "other": {
                  "content": {
                    "id": "CVE-2024-48777",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-10-15T18:27:07.729500Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "problemTypes": [
              {
                "descriptions": [
                  {
                    "cweId": "CWE-306",
                    "description": "CWE-306 Missing Authentication for Critical Function",
                    "lang": "en",
                    "type": "CWE"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-10-15T18:43:15.758Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "LEDVANCE com.ledvance.smartplus.eu 2.1.10 allows a remote attacker to obtain sensitive information via the firmware update process."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-07-05T16:04:46.092Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "url": "https://github.com/HankJames/Vul-Reports/blob/main/FirmwareLeakage/com.ledvance.smartplus.eu/com.ledvance.smartplus.eu.md"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2024-48777",
        "datePublished": "2024-10-11T00:00:00.000Z",
        "dateReserved": "2024-10-08T00:00:00.000Z",
        "dateUpdated": "2026-07-05T16:04:46.092Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",