Find a vulnerability
Search criteria
3 vulnerabilities by guardzilla
VAR-201812-0070
Vulnerability from variot - Updated: 2025-05-07 23:17The remote upgrade feature in Guardzilla GZ180 devices allow command injection via a crafted new firmware version parameter. Guardzilla GZ180 The device contains a command injection vulnerability.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. The Guardzilla GZ180 is a home security surveillance camera
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-201812-0070",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "180 indoor",
"scope": "eq",
"trust": 1.0,
"vendor": "guardzilla",
"version": null
},
{
"model": "180 outdoor",
"scope": "eq",
"trust": 1.0,
"vendor": "guardzilla",
"version": null
},
{
"model": "180 indoor",
"scope": null,
"trust": 0.8,
"vendor": "guardzilla",
"version": null
},
{
"model": "180 outdoor",
"scope": null,
"trust": 0.8,
"vendor": "guardzilla",
"version": null
},
{
"model": "gz180 guardzilla gz180",
"scope": null,
"trust": 0.6,
"vendor": "guardzilla",
"version": null
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2019-00833"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-013845"
},
{
"db": "NVD",
"id": "CVE-2018-18600"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"cpe_match": [
{
"cpe22Uri": "cpe:/o:guardzilla:180_indoor_firmware",
"vulnerable": true
},
{
"cpe22Uri": "cpe:/o:guardzilla:180_outdoor_firmware",
"vulnerable": true
}
],
"operator": "OR"
}
]
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2018-013845"
}
]
},
"cve": "CVE-2018-18600",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"accessComplexity": "MEDIUM",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "nvd@nist.gov",
"availabilityImpact": "COMPLETE",
"baseScore": 9.3,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 8.6,
"id": "CVE-2018-18600",
"impactScore": 10.0,
"integrityImpact": "COMPLETE",
"severity": "HIGH",
"trust": 1.8,
"vectorString": "AV:N/AC:M/Au:N/C:C/I:C/A:C",
"version": "2.0"
},
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "CNVD",
"availabilityImpact": "PARTIAL",
"baseScore": 7.5,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 10.0,
"id": "CNVD-2019-00833",
"impactScore": 6.4,
"integrityImpact": "PARTIAL",
"severity": "HIGH",
"trust": 0.6,
"vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
"version": "2.0"
},
{
"accessComplexity": "MEDIUM",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "VULHUB",
"availabilityImpact": "COMPLETE",
"baseScore": 9.3,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 8.6,
"id": "VHN-129176",
"impactScore": 10.0,
"integrityImpact": "COMPLETE",
"severity": "HIGH",
"trust": 0.1,
"vectorString": "AV:N/AC:M/AU:N/C:C/I:C/A:C",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "HIGH",
"attackVector": "NETWORK",
"author": "nvd@nist.gov",
"availabilityImpact": "HIGH",
"baseScore": 8.1,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 2.2,
"id": "CVE-2018-18600",
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.8,
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
},
{
"attackComplexity": "HIGH",
"attackVector": "NETWORK",
"author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"availabilityImpact": "HIGH",
"baseScore": 8.1,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 2.2,
"id": "CVE-2018-18600",
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
],
"severity": [
{
"author": "nvd@nist.gov",
"id": "CVE-2018-18600",
"trust": 1.0,
"value": "HIGH"
},
{
"author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"id": "CVE-2018-18600",
"trust": 1.0,
"value": "HIGH"
},
{
"author": "NVD",
"id": "CVE-2018-18600",
"trust": 0.8,
"value": "High"
},
{
"author": "CNVD",
"id": "CNVD-2019-00833",
"trust": 0.6,
"value": "HIGH"
},
{
"author": "CNNVD",
"id": "CNNVD-201812-1304",
"trust": 0.6,
"value": "HIGH"
},
{
"author": "VULHUB",
"id": "VHN-129176",
"trust": 0.1,
"value": "HIGH"
}
]
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2019-00833"
},
{
"db": "VULHUB",
"id": "VHN-129176"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-013845"
},
{
"db": "CNNVD",
"id": "CNNVD-201812-1304"
},
{
"db": "NVD",
"id": "CVE-2018-18600"
},
{
"db": "NVD",
"id": "CVE-2018-18600"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "The remote upgrade feature in Guardzilla GZ180 devices allow command injection via a crafted new firmware version parameter. Guardzilla GZ180 The device contains a command injection vulnerability.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. The Guardzilla GZ180 is a home security surveillance camera",
"sources": [
{
"db": "NVD",
"id": "CVE-2018-18600"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-013845"
},
{
"db": "CNVD",
"id": "CNVD-2019-00833"
},
{
"db": "VULHUB",
"id": "VHN-129176"
}
],
"trust": 2.25
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2018-18600",
"trust": 3.1
},
{
"db": "JVNDB",
"id": "JVNDB-2018-013845",
"trust": 0.8
},
{
"db": "CNNVD",
"id": "CNNVD-201812-1304",
"trust": 0.7
},
{
"db": "CNVD",
"id": "CNVD-2019-00833",
"trust": 0.6
},
{
"db": "VULHUB",
"id": "VHN-129176",
"trust": 0.1
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2019-00833"
},
{
"db": "VULHUB",
"id": "VHN-129176"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-013845"
},
{
"db": "CNNVD",
"id": "CNNVD-201812-1304"
},
{
"db": "NVD",
"id": "CVE-2018-18600"
}
]
},
"id": "VAR-201812-0070",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2019-00833"
},
{
"db": "VULHUB",
"id": "VHN-129176"
}
],
"trust": 1.7
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"Network device"
],
"sub_category": null,
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2019-00833"
}
]
},
"last_update_date": "2025-05-07T23:17:42.428000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "Top Page",
"trust": 0.8,
"url": "https://www.guardzilla.com/"
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2018-013845"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-78",
"trust": 1.1
},
{
"problemtype": "CWE-77",
"trust": 0.9
}
],
"sources": [
{
"db": "VULHUB",
"id": "VHN-129176"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-013845"
},
{
"db": "NVD",
"id": "CVE-2018-18600"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 2.5,
"url": "https://labs.bitdefender.com/2018/12/iot-report-major-flaws-in-guardzilla-cameras-allow-remote-hijack-of-the-security-device/"
},
{
"trust": 1.4,
"url": "https://nvd.nist.gov/vuln/detail/cve-2018-18600"
},
{
"trust": 0.8,
"url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2018-18600"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2019-00833"
},
{
"db": "VULHUB",
"id": "VHN-129176"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-013845"
},
{
"db": "CNNVD",
"id": "CNNVD-201812-1304"
},
{
"db": "NVD",
"id": "CVE-2018-18600"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "CNVD",
"id": "CNVD-2019-00833"
},
{
"db": "VULHUB",
"id": "VHN-129176"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-013845"
},
{
"db": "CNNVD",
"id": "CNNVD-201812-1304"
},
{
"db": "NVD",
"id": "CVE-2018-18600"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2019-01-10T00:00:00",
"db": "CNVD",
"id": "CNVD-2019-00833"
},
{
"date": "2018-12-31T00:00:00",
"db": "VULHUB",
"id": "VHN-129176"
},
{
"date": "2019-03-04T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2018-013845"
},
{
"date": "2019-01-02T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201812-1304"
},
{
"date": "2018-12-31T16:29:00.250000",
"db": "NVD",
"id": "CVE-2018-18600"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2019-01-10T00:00:00",
"db": "CNVD",
"id": "CNVD-2019-00833"
},
{
"date": "2019-10-03T00:00:00",
"db": "VULHUB",
"id": "VHN-129176"
},
{
"date": "2019-03-04T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2018-013845"
},
{
"date": "2019-10-23T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201812-1304"
},
{
"date": "2025-05-06T19:15:52.410000",
"db": "NVD",
"id": "CVE-2018-18600"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-201812-1304"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Guardzilla GZ180 Command Injection Vulnerability",
"sources": [
{
"db": "CNVD",
"id": "CNVD-2019-00833"
},
{
"db": "CNNVD",
"id": "CNNVD-201812-1304"
}
],
"trust": 1.2
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "operating system commend injection",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-201812-1304"
}
],
"trust": 0.6
}
}
VAR-201812-0071
Vulnerability from variot - Updated: 2025-05-07 23:00The TK_set_deviceModel_req_handle function in the cloud communication component in Guardzilla GZ621W devices with firmware 0.5.1.4 has a Buffer Overflow. Guardzilla GZ621W The device firmware contains a buffer error vulnerability.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. The Guardzilla GZ621W is a home security surveillance camera. A remote attacker could exploit the vulnerability to execute code
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-201812-0071",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "gz621w",
"scope": "eq",
"trust": 1.8,
"vendor": "guardzilla",
"version": "0.5.1.4"
},
{
"model": "gz621w guardzilla gz621w",
"scope": "eq",
"trust": 0.6,
"vendor": "guardzilla",
"version": "0.5.1.4"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2019-00832"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-014599"
},
{
"db": "NVD",
"id": "CVE-2018-18601"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"cpe_match": [
{
"cpe22Uri": "cpe:/o:guardzilla:gz621w_firmware",
"vulnerable": true
}
],
"operator": "OR"
}
]
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2018-014599"
}
]
},
"cve": "CVE-2018-18601",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"accessComplexity": "MEDIUM",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "nvd@nist.gov",
"availabilityImpact": "PARTIAL",
"baseScore": 6.8,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 8.6,
"id": "CVE-2018-18601",
"impactScore": 6.4,
"integrityImpact": "PARTIAL",
"severity": "MEDIUM",
"trust": 1.8,
"vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P",
"version": "2.0"
},
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "CNVD",
"availabilityImpact": "PARTIAL",
"baseScore": 7.5,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 10.0,
"id": "CNVD-2019-00832",
"impactScore": 6.4,
"integrityImpact": "PARTIAL",
"severity": "HIGH",
"trust": 0.6,
"vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
"version": "2.0"
},
{
"accessComplexity": "MEDIUM",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "VULHUB",
"availabilityImpact": "PARTIAL",
"baseScore": 6.8,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 8.6,
"id": "VHN-129177",
"impactScore": 6.4,
"integrityImpact": "PARTIAL",
"severity": "MEDIUM",
"trust": 0.1,
"vectorString": "AV:N/AC:M/AU:N/C:P/I:P/A:P",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "HIGH",
"attackVector": "NETWORK",
"author": "nvd@nist.gov",
"availabilityImpact": "HIGH",
"baseScore": 8.1,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 2.2,
"id": "CVE-2018-18601",
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.8,
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
},
{
"attackComplexity": "HIGH",
"attackVector": "NETWORK",
"author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"availabilityImpact": "HIGH",
"baseScore": 8.1,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 2.2,
"id": "CVE-2018-18601",
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
],
"severity": [
{
"author": "nvd@nist.gov",
"id": "CVE-2018-18601",
"trust": 1.0,
"value": "HIGH"
},
{
"author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"id": "CVE-2018-18601",
"trust": 1.0,
"value": "HIGH"
},
{
"author": "NVD",
"id": "CVE-2018-18601",
"trust": 0.8,
"value": "High"
},
{
"author": "CNVD",
"id": "CNVD-2019-00832",
"trust": 0.6,
"value": "HIGH"
},
{
"author": "CNNVD",
"id": "CNNVD-201812-1305",
"trust": 0.6,
"value": "HIGH"
},
{
"author": "VULHUB",
"id": "VHN-129177",
"trust": 0.1,
"value": "MEDIUM"
}
]
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2019-00832"
},
{
"db": "VULHUB",
"id": "VHN-129177"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-014599"
},
{
"db": "CNNVD",
"id": "CNNVD-201812-1305"
},
{
"db": "NVD",
"id": "CVE-2018-18601"
},
{
"db": "NVD",
"id": "CVE-2018-18601"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "The TK_set_deviceModel_req_handle function in the cloud communication component in Guardzilla GZ621W devices with firmware 0.5.1.4 has a Buffer Overflow. Guardzilla GZ621W The device firmware contains a buffer error vulnerability.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. The Guardzilla GZ621W is a home security surveillance camera. A remote attacker could exploit the vulnerability to execute code",
"sources": [
{
"db": "NVD",
"id": "CVE-2018-18601"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-014599"
},
{
"db": "CNVD",
"id": "CNVD-2019-00832"
},
{
"db": "VULHUB",
"id": "VHN-129177"
}
],
"trust": 2.25
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2018-18601",
"trust": 3.1
},
{
"db": "JVNDB",
"id": "JVNDB-2018-014599",
"trust": 0.8
},
{
"db": "CNNVD",
"id": "CNNVD-201812-1305",
"trust": 0.7
},
{
"db": "CNVD",
"id": "CNVD-2019-00832",
"trust": 0.6
},
{
"db": "VULHUB",
"id": "VHN-129177",
"trust": 0.1
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2019-00832"
},
{
"db": "VULHUB",
"id": "VHN-129177"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-014599"
},
{
"db": "CNNVD",
"id": "CNNVD-201812-1305"
},
{
"db": "NVD",
"id": "CVE-2018-18601"
}
]
},
"id": "VAR-201812-0071",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2019-00832"
},
{
"db": "VULHUB",
"id": "VHN-129177"
}
],
"trust": 1.7
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"Network device"
],
"sub_category": null,
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2019-00832"
}
]
},
"last_update_date": "2025-05-07T23:00:32.967000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "Top Page",
"trust": 0.8,
"url": "https://www.guardzilla.com/"
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2018-014599"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-119",
"trust": 1.9
}
],
"sources": [
{
"db": "VULHUB",
"id": "VHN-129177"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-014599"
},
{
"db": "NVD",
"id": "CVE-2018-18601"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 2.5,
"url": "https://labs.bitdefender.com/2018/12/iot-report-major-flaws-in-guardzilla-cameras-allow-remote-hijack-of-the-security-device/"
},
{
"trust": 1.4,
"url": "https://nvd.nist.gov/vuln/detail/cve-2018-18601"
},
{
"trust": 0.8,
"url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2018-18601"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2019-00832"
},
{
"db": "VULHUB",
"id": "VHN-129177"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-014599"
},
{
"db": "CNNVD",
"id": "CNNVD-201812-1305"
},
{
"db": "NVD",
"id": "CVE-2018-18601"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "CNVD",
"id": "CNVD-2019-00832"
},
{
"db": "VULHUB",
"id": "VHN-129177"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-014599"
},
{
"db": "CNNVD",
"id": "CNNVD-201812-1305"
},
{
"db": "NVD",
"id": "CVE-2018-18601"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2019-01-10T00:00:00",
"db": "CNVD",
"id": "CNVD-2019-00832"
},
{
"date": "2018-12-31T00:00:00",
"db": "VULHUB",
"id": "VHN-129177"
},
{
"date": "2019-03-29T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2018-014599"
},
{
"date": "2019-01-02T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201812-1305"
},
{
"date": "2018-12-31T16:29:00.313000",
"db": "NVD",
"id": "CVE-2018-18601"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2019-01-10T00:00:00",
"db": "CNVD",
"id": "CNVD-2019-00832"
},
{
"date": "2019-02-20T00:00:00",
"db": "VULHUB",
"id": "VHN-129177"
},
{
"date": "2019-03-29T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2018-014599"
},
{
"date": "2019-02-25T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201812-1305"
},
{
"date": "2025-05-06T19:15:52.917000",
"db": "NVD",
"id": "CVE-2018-18601"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-201812-1305"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Guardzilla GZ621W Device firmware buffer error vulnerability",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2018-014599"
}
],
"trust": 0.8
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "buffer error",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-201812-1305"
}
],
"trust": 0.6
}
}
VAR-201901-1595
Vulnerability from variot - Updated: 2024-11-23 21:37A reliance on a static, hard-coded credential in the design of the cloud-based storage system of Practecol's Guardzilla All-In-One Video Security System allows an attacker to view the private data of all users of the Guardzilla device. Practecol Guardzilla All-In-One Video Security System Contains a vulnerability in the use of hard-coded credentials.Information may be obtained. GuardzillaAll-In-OneVideoSecuritySystem is a home security platform that provides indoor video surveillance. There is a hard-coded credential vulnerability in the Guardzilla IoT camera. This vulnerability exists in Amazon Simple Storage Service (S3) credentials within the Guardzilla Security Camera firmware. Use embedded S3 credentials to unrestrictedly view and download any stored files and videos in the associated bucket. Once a password is obtained, any unauthenticated attacker can collect data from any affected system over the network. Cloud-based storage system is one of the cloud-based storage systems. An attacker could exploit this vulnerability to view all Guardzilla personal data
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-201901-1595",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "gz521w",
"scope": "eq",
"trust": 1.0,
"vendor": "guardzilla",
"version": "*"
},
{
"model": "gz521w",
"scope": null,
"trust": 0.8,
"vendor": "guardzilla",
"version": null
},
{
"model": "gz521wb security video system",
"scope": null,
"trust": 0.6,
"vendor": "guardzilla",
"version": null
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2019-00567"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-014572"
},
{
"db": "NVD",
"id": "CVE-2018-5560"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"cpe_match": [
{
"cpe22Uri": "cpe:/o:guardzilla:gz521w_firmware",
"vulnerable": true
}
],
"operator": "OR"
}
]
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2018-014572"
}
]
},
"cve": "CVE-2018-5560",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "nvd@nist.gov",
"availabilityImpact": "NONE",
"baseScore": 5.0,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 10.0,
"id": "CVE-2018-5560",
"impactScore": 2.9,
"integrityImpact": "NONE",
"severity": "MEDIUM",
"trust": 1.8,
"vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N",
"version": "2.0"
},
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "CNVD",
"availabilityImpact": "NONE",
"baseScore": 7.8,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 10.0,
"id": "CNVD-2019-00567",
"impactScore": 6.9,
"integrityImpact": "NONE",
"severity": "HIGH",
"trust": 0.6,
"vectorString": "AV:N/AC:L/Au:N/C:C/I:N/A:N",
"version": "2.0"
},
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "VULHUB",
"availabilityImpact": "NONE",
"baseScore": 5.0,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 10.0,
"id": "VHN-135591",
"impactScore": 2.9,
"integrityImpact": "NONE",
"severity": "MEDIUM",
"trust": 0.1,
"vectorString": "AV:N/AC:L/AU:N/C:P/I:N/A:N",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "nvd@nist.gov",
"availabilityImpact": "NONE",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 3.9,
"id": "CVE-2018-5560",
"impactScore": 3.6,
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.8,
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
"version": "3.0"
},
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "cve@rapid7.com",
"availabilityImpact": "NONE",
"baseScore": 10.0,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 3.9,
"id": "CVE-2018-5560",
"impactScore": 5.8,
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:N",
"version": "3.0"
}
],
"severity": [
{
"author": "nvd@nist.gov",
"id": "CVE-2018-5560",
"trust": 1.0,
"value": "HIGH"
},
{
"author": "cve@rapid7.com",
"id": "CVE-2018-5560",
"trust": 1.0,
"value": "CRITICAL"
},
{
"author": "NVD",
"id": "CVE-2018-5560",
"trust": 0.8,
"value": "High"
},
{
"author": "CNVD",
"id": "CNVD-2019-00567",
"trust": 0.6,
"value": "HIGH"
},
{
"author": "CNNVD",
"id": "CNNVD-201901-1059",
"trust": 0.6,
"value": "HIGH"
},
{
"author": "VULHUB",
"id": "VHN-135591",
"trust": 0.1,
"value": "MEDIUM"
}
]
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2019-00567"
},
{
"db": "VULHUB",
"id": "VHN-135591"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-014572"
},
{
"db": "CNNVD",
"id": "CNNVD-201901-1059"
},
{
"db": "NVD",
"id": "CVE-2018-5560"
},
{
"db": "NVD",
"id": "CVE-2018-5560"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "A reliance on a static, hard-coded credential in the design of the cloud-based storage system of Practecol\u0027s Guardzilla All-In-One Video Security System allows an attacker to view the private data of all users of the Guardzilla device. Practecol Guardzilla All-In-One Video Security System Contains a vulnerability in the use of hard-coded credentials.Information may be obtained. GuardzillaAll-In-OneVideoSecuritySystem is a home security platform that provides indoor video surveillance. There is a hard-coded credential vulnerability in the Guardzilla IoT camera. This vulnerability exists in Amazon Simple Storage Service (S3) credentials within the Guardzilla Security Camera firmware. Use embedded S3 credentials to unrestrictedly view and download any stored files and videos in the associated bucket. Once a password is obtained, any unauthenticated attacker can collect data from any affected system over the network. Cloud-based storage system is one of the cloud-based storage systems. An attacker could exploit this vulnerability to view all Guardzilla personal data",
"sources": [
{
"db": "NVD",
"id": "CVE-2018-5560"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-014572"
},
{
"db": "CNVD",
"id": "CNVD-2019-00567"
},
{
"db": "VULHUB",
"id": "VHN-135591"
}
],
"trust": 2.25
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2018-5560",
"trust": 3.1
},
{
"db": "JVNDB",
"id": "JVNDB-2018-014572",
"trust": 0.8
},
{
"db": "CNNVD",
"id": "CNNVD-201901-1059",
"trust": 0.7
},
{
"db": "CNVD",
"id": "CNVD-2019-00567",
"trust": 0.6
},
{
"db": "VULHUB",
"id": "VHN-135591",
"trust": 0.1
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2019-00567"
},
{
"db": "VULHUB",
"id": "VHN-135591"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-014572"
},
{
"db": "CNNVD",
"id": "CNNVD-201901-1059"
},
{
"db": "NVD",
"id": "CVE-2018-5560"
}
]
},
"id": "VAR-201901-1595",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2019-00567"
},
{
"db": "VULHUB",
"id": "VHN-135591"
}
],
"trust": 1.7
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"Network device"
],
"sub_category": null,
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2019-00567"
}
]
},
"last_update_date": "2024-11-23T21:37:43.177000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "Top Page",
"trust": 0.8,
"url": "https://www.guardzilla.com/"
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2018-014572"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-798",
"trust": 1.9
}
],
"sources": [
{
"db": "VULHUB",
"id": "VHN-135591"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-014572"
},
{
"db": "NVD",
"id": "CVE-2018-5560"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 2.5,
"url": "https://www.0dayallday.org/guardzilla-video-camera-hard-coded-aws-credentials/"
},
{
"trust": 1.7,
"url": "https://blog.rapid7.com/2018/12/27/r7-2018-52-guardzilla-iot-video-camera-hard-coded-credential-cve-2018-5560/"
},
{
"trust": 1.4,
"url": "https://nvd.nist.gov/vuln/detail/cve-2018-5560"
},
{
"trust": 0.8,
"url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2018-5560"
},
{
"trust": 0.6,
"url": "http://0day5.com/archives/4512/"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2019-00567"
},
{
"db": "VULHUB",
"id": "VHN-135591"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-014572"
},
{
"db": "CNNVD",
"id": "CNNVD-201901-1059"
},
{
"db": "NVD",
"id": "CVE-2018-5560"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "CNVD",
"id": "CNVD-2019-00567"
},
{
"db": "VULHUB",
"id": "VHN-135591"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-014572"
},
{
"db": "CNNVD",
"id": "CNNVD-201901-1059"
},
{
"db": "NVD",
"id": "CVE-2018-5560"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2019-01-07T00:00:00",
"db": "CNVD",
"id": "CNVD-2019-00567"
},
{
"date": "2019-01-31T00:00:00",
"db": "VULHUB",
"id": "VHN-135591"
},
{
"date": "2019-03-27T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2018-014572"
},
{
"date": "2019-01-31T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201901-1059"
},
{
"date": "2019-01-31T21:29:00.270000",
"db": "NVD",
"id": "CVE-2018-5560"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2019-01-07T00:00:00",
"db": "CNVD",
"id": "CNVD-2019-00567"
},
{
"date": "2019-10-09T00:00:00",
"db": "VULHUB",
"id": "VHN-135591"
},
{
"date": "2019-03-27T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2018-014572"
},
{
"date": "2019-10-10T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201901-1059"
},
{
"date": "2024-11-21T04:09:03.990000",
"db": "NVD",
"id": "CVE-2018-5560"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-201901-1059"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Practecol Guardzilla All-In-One Video Security System Vulnerabilities related to the use of hard-coded credentials",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2018-014572"
}
],
"trust": 0.8
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "trust management problem",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-201901-1059"
}
],
"trust": 0.6
}
}