    Vulnerability from variot - Updated: 2024-11-23 22:21

    The Eques elf smart plug and the mobile app use a hardcoded AES 256 bit key to encrypt the commands and responses between the device and the app. The communication happens over UDP port 27431. An attacker on the local network can use the same key to encrypt and send commands to discover all smart plugs in a network, take over control of a device, and perform actions such as turning it on and off. There is a security hole in the Eques Technology elf smart plug

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-201908-0981",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "elf smart plug",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "equeshome",
            "version": null
          },
          {
            "model": "elf smart plug",
            "scope": null,
            "trust": 0.8,
            "vendor": "equeshome",
            "version": null
          },
          {
            "model": "technology elf smart plug",
            "scope": null,
            "trust": 0.6,
            "vendor": "eques",
            "version": null
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2019-31320"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2019-008908"
          },
          {
            "db": "NVD",
            "id": "CVE-2019-15745"
          }
        ]
      },
      "configurations": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/configurations#",
          "children": {
            "@container": "@list"
          },
          "cpe_match": {
            "@container": "@list"
          },
          "data": {
            "@container": "@list"
          },
          "nodes": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "CVE_data_version": "4.0",
            "nodes": [
              {
                "cpe_match": [
                  {
                    "cpe22Uri": "cpe:/o:equeshome:elf_smart_plug_firmware",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2019-008908"
          }
        ]
      },
      "cve": "CVE-2019-15745",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "accessComplexity": "LOW",
                "accessVector": "ADJACENT_NETWORK",
                "authentication": "NONE",
                "author": "nvd@nist.gov",
                "availabilityImpact": "NONE",
                "baseScore": 3.3,
                "confidentialityImpact": "PARTIAL",
                "exploitabilityScore": 6.5,
                "id": "CVE-2019-15745",
                "impactScore": 2.9,
                "integrityImpact": "NONE",
                "severity": "LOW",
                "trust": 1.8,
                "vectorString": "AV:A/AC:L/Au:N/C:P/I:N/A:N",
                "version": "2.0"
              },
              {
                "accessComplexity": "LOW",
                "accessVector": "ADJACENT_NETWORK",
                "authentication": "NONE",
                "author": "CNVD",
                "availabilityImpact": "NONE",
                "baseScore": 3.3,
                "confidentialityImpact": "PARTIAL",
                "exploitabilityScore": 6.5,
                "id": "CNVD-2019-31320",
                "impactScore": 2.9,
                "integrityImpact": "NONE",
                "severity": "LOW",
                "trust": 0.6,
                "vectorString": "AV:A/AC:L/Au:N/C:P/I:N/A:N",
                "version": "2.0"
              },
              {
                "accessComplexity": "LOW",
                "accessVector": "ADJACENT_NETWORK",
                "authentication": "NONE",
                "author": "VULHUB",
                "availabilityImpact": "NONE",
                "baseScore": 3.3,
                "confidentialityImpact": "PARTIAL",
                "exploitabilityScore": 6.5,
                "id": "VHN-147822",
                "impactScore": 2.9,
                "integrityImpact": "NONE",
                "severity": "LOW",
                "trust": 0.1,
                "vectorString": "AV:A/AC:L/AU:N/C:P/I:N/A:N",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "ADJACENT",
                "author": "nvd@nist.gov",
                "availabilityImpact": "HIGH",
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 2.8,
                "id": "CVE-2019-15745",
                "impactScore": 5.9,
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "trust": 1.8,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "nvd@nist.gov",
                "id": "CVE-2019-15745",
                "trust": 1.0,
                "value": "HIGH"
              },
              {
                "author": "NVD",
                "id": "CVE-2019-15745",
                "trust": 0.8,
                "value": "High"
              },
              {
                "author": "CNVD",
                "id": "CNVD-2019-31320",
                "trust": 0.6,
                "value": "LOW"
              },
              {
                "author": "CNNVD",
                "id": "CNNVD-201908-2207",
                "trust": 0.6,
                "value": "HIGH"
              },
              {
                "author": "VULHUB",
                "id": "VHN-147822",
                "trust": 0.1,
                "value": "LOW"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2019-31320"
          },
          {
            "db": "VULHUB",
            "id": "VHN-147822"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2019-008908"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201908-2207"
          },
          {
            "db": "NVD",
            "id": "CVE-2019-15745"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "The Eques elf smart plug and the mobile app use a hardcoded AES 256 bit key to encrypt the commands and responses between the device and the app. The communication happens over UDP port 27431. An attacker on the local network can use the same key to encrypt and send commands to discover all smart plugs in a network, take over control of a device, and perform actions such as turning it on and off. There is a security hole in the Eques Technology elf smart plug",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2019-15745"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2019-008908"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2019-31320"
          },
          {
            "db": "VULHUB",
            "id": "VHN-147822"
          }
        ],
        "trust": 2.25
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2019-15745",
            "trust": 3.1
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2019-008908",
            "trust": 0.8
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201908-2207",
            "trust": 0.7
          },
          {
            "db": "CNVD",
            "id": "CNVD-2019-31320",
            "trust": 0.6
          },
          {
            "db": "VULHUB",
            "id": "VHN-147822",
            "trust": 0.1
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2019-31320"
          },
          {
            "db": "VULHUB",
            "id": "VHN-147822"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2019-008908"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201908-2207"
          },
          {
            "db": "NVD",
            "id": "CVE-2019-15745"
          }
        ]
      },
      "id": "VAR-201908-0981",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2019-31320"
          },
          {
            "db": "VULHUB",
            "id": "VHN-147822"
          }
        ],
        "trust": 1.7
      },
      "iot_taxonomy": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "category": [
              "IoT"
            ],
            "sub_category": null,
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2019-31320"
          }
        ]
      },
      "last_update_date": "2024-11-23T22:21:32.895000Z",
      "patch": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/patch#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "title": "Elf Smart Plug",
            "trust": 0.8,
            "url": "https://equeshome.com/products/elf-smart-plug"
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2019-008908"
          }
        ]
      },
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-798",
            "trust": 1.9
          }
        ],
        "sources": [
          {
            "db": "VULHUB",
            "id": "VHN-147822"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2019-008908"
          },
          {
            "db": "NVD",
            "id": "CVE-2019-15745"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 2.5,
            "url": "https://github.com/iamckn/eques"
          },
          {
            "trust": 2.0,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2019-15745"
          },
          {
            "trust": 1.7,
            "url": "https://www.ckn.io/blog/2019/08/27/exploiting-the-eques-elf-smart-plug-part-four/"
          },
          {
            "trust": 1.7,
            "url": "https://www.ckn.io/blog/2019/08/27/exploiting-the-eques-elf-smart-plug-part-one/"
          },
          {
            "trust": 1.7,
            "url": "https://www.ckn.io/blog/2019/08/27/exploiting-the-eques-elf-smart-plug-part-three/"
          },
          {
            "trust": 1.7,
            "url": "https://www.ckn.io/blog/2019/08/27/exploiting-the-eques-elf-smart-plug-part-two/"
          },
          {
            "trust": 0.8,
            "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2019-15745"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2019-31320"
          },
          {
            "db": "VULHUB",
            "id": "VHN-147822"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2019-008908"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201908-2207"
          },
          {
            "db": "NVD",
            "id": "CVE-2019-15745"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "CNVD",
            "id": "CNVD-2019-31320"
          },
          {
            "db": "VULHUB",
            "id": "VHN-147822"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2019-008908"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201908-2207"
          },
          {
            "db": "NVD",
            "id": "CVE-2019-15745"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2019-09-14T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2019-31320"
          },
          {
            "date": "2019-08-29T00:00:00",
            "db": "VULHUB",
            "id": "VHN-147822"
          },
          {
            "date": "2019-09-09T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2019-008908"
          },
          {
            "date": "2019-08-29T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-201908-2207"
          },
          {
            "date": "2019-08-29T13:15:11.227000",
            "db": "NVD",
            "id": "CVE-2019-15745"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2019-09-14T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2019-31320"
          },
          {
            "date": "2019-09-05T00:00:00",
            "db": "VULHUB",
            "id": "VHN-147822"
          },
          {
            "date": "2019-09-09T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2019-008908"
          },
          {
            "date": "2019-09-06T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-201908-2207"
          },
          {
            "date": "2024-11-21T04:29:23.397000",
            "db": "NVD",
            "id": "CVE-2019-15745"
          }
        ]
      },
      "threat_type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "remote or local",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-201908-2207"
          }
        ],
        "trust": 0.6
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Eques elf Vulnerabilities related to the use of hard-coded credentials in smart plugs and mobile applications",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2019-008908"
          }
        ],
        "trust": 0.8
      },
      "type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "trust management problem",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-201908-2207"
          }
        ],
        "trust": 0.6
      }
    }