Search
Find a vulnerability
Search criteria
1 vulnerability by eques
VAR-201908-0981
Vulnerability from variot - Updated: 2024-11-23 22:21The Eques elf smart plug and the mobile app use a hardcoded AES 256 bit key to encrypt the commands and responses between the device and the app. The communication happens over UDP port 27431. An attacker on the local network can use the same key to encrypt and send commands to discover all smart plugs in a network, take over control of a device, and perform actions such as turning it on and off. There is a security hole in the Eques Technology elf smart plug
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-201908-0981",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "elf smart plug",
"scope": "eq",
"trust": 1.0,
"vendor": "equeshome",
"version": null
},
{
"model": "elf smart plug",
"scope": null,
"trust": 0.8,
"vendor": "equeshome",
"version": null
},
{
"model": "technology elf smart plug",
"scope": null,
"trust": 0.6,
"vendor": "eques",
"version": null
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2019-31320"
},
{
"db": "JVNDB",
"id": "JVNDB-2019-008908"
},
{
"db": "NVD",
"id": "CVE-2019-15745"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"cpe_match": [
{
"cpe22Uri": "cpe:/o:equeshome:elf_smart_plug_firmware",
"vulnerable": true
}
],
"operator": "OR"
}
]
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2019-008908"
}
]
},
"cve": "CVE-2019-15745",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"accessComplexity": "LOW",
"accessVector": "ADJACENT_NETWORK",
"authentication": "NONE",
"author": "nvd@nist.gov",
"availabilityImpact": "NONE",
"baseScore": 3.3,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 6.5,
"id": "CVE-2019-15745",
"impactScore": 2.9,
"integrityImpact": "NONE",
"severity": "LOW",
"trust": 1.8,
"vectorString": "AV:A/AC:L/Au:N/C:P/I:N/A:N",
"version": "2.0"
},
{
"accessComplexity": "LOW",
"accessVector": "ADJACENT_NETWORK",
"authentication": "NONE",
"author": "CNVD",
"availabilityImpact": "NONE",
"baseScore": 3.3,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 6.5,
"id": "CNVD-2019-31320",
"impactScore": 2.9,
"integrityImpact": "NONE",
"severity": "LOW",
"trust": 0.6,
"vectorString": "AV:A/AC:L/Au:N/C:P/I:N/A:N",
"version": "2.0"
},
{
"accessComplexity": "LOW",
"accessVector": "ADJACENT_NETWORK",
"authentication": "NONE",
"author": "VULHUB",
"availabilityImpact": "NONE",
"baseScore": 3.3,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 6.5,
"id": "VHN-147822",
"impactScore": 2.9,
"integrityImpact": "NONE",
"severity": "LOW",
"trust": 0.1,
"vectorString": "AV:A/AC:L/AU:N/C:P/I:N/A:N",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "ADJACENT",
"author": "nvd@nist.gov",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 2.8,
"id": "CVE-2019-15745",
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.8,
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "nvd@nist.gov",
"id": "CVE-2019-15745",
"trust": 1.0,
"value": "HIGH"
},
{
"author": "NVD",
"id": "CVE-2019-15745",
"trust": 0.8,
"value": "High"
},
{
"author": "CNVD",
"id": "CNVD-2019-31320",
"trust": 0.6,
"value": "LOW"
},
{
"author": "CNNVD",
"id": "CNNVD-201908-2207",
"trust": 0.6,
"value": "HIGH"
},
{
"author": "VULHUB",
"id": "VHN-147822",
"trust": 0.1,
"value": "LOW"
}
]
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2019-31320"
},
{
"db": "VULHUB",
"id": "VHN-147822"
},
{
"db": "JVNDB",
"id": "JVNDB-2019-008908"
},
{
"db": "CNNVD",
"id": "CNNVD-201908-2207"
},
{
"db": "NVD",
"id": "CVE-2019-15745"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "The Eques elf smart plug and the mobile app use a hardcoded AES 256 bit key to encrypt the commands and responses between the device and the app. The communication happens over UDP port 27431. An attacker on the local network can use the same key to encrypt and send commands to discover all smart plugs in a network, take over control of a device, and perform actions such as turning it on and off. There is a security hole in the Eques Technology elf smart plug",
"sources": [
{
"db": "NVD",
"id": "CVE-2019-15745"
},
{
"db": "JVNDB",
"id": "JVNDB-2019-008908"
},
{
"db": "CNVD",
"id": "CNVD-2019-31320"
},
{
"db": "VULHUB",
"id": "VHN-147822"
}
],
"trust": 2.25
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2019-15745",
"trust": 3.1
},
{
"db": "JVNDB",
"id": "JVNDB-2019-008908",
"trust": 0.8
},
{
"db": "CNNVD",
"id": "CNNVD-201908-2207",
"trust": 0.7
},
{
"db": "CNVD",
"id": "CNVD-2019-31320",
"trust": 0.6
},
{
"db": "VULHUB",
"id": "VHN-147822",
"trust": 0.1
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2019-31320"
},
{
"db": "VULHUB",
"id": "VHN-147822"
},
{
"db": "JVNDB",
"id": "JVNDB-2019-008908"
},
{
"db": "CNNVD",
"id": "CNNVD-201908-2207"
},
{
"db": "NVD",
"id": "CVE-2019-15745"
}
]
},
"id": "VAR-201908-0981",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2019-31320"
},
{
"db": "VULHUB",
"id": "VHN-147822"
}
],
"trust": 1.7
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"IoT"
],
"sub_category": null,
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2019-31320"
}
]
},
"last_update_date": "2024-11-23T22:21:32.895000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "Elf Smart Plug",
"trust": 0.8,
"url": "https://equeshome.com/products/elf-smart-plug"
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2019-008908"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-798",
"trust": 1.9
}
],
"sources": [
{
"db": "VULHUB",
"id": "VHN-147822"
},
{
"db": "JVNDB",
"id": "JVNDB-2019-008908"
},
{
"db": "NVD",
"id": "CVE-2019-15745"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 2.5,
"url": "https://github.com/iamckn/eques"
},
{
"trust": 2.0,
"url": "https://nvd.nist.gov/vuln/detail/cve-2019-15745"
},
{
"trust": 1.7,
"url": "https://www.ckn.io/blog/2019/08/27/exploiting-the-eques-elf-smart-plug-part-four/"
},
{
"trust": 1.7,
"url": "https://www.ckn.io/blog/2019/08/27/exploiting-the-eques-elf-smart-plug-part-one/"
},
{
"trust": 1.7,
"url": "https://www.ckn.io/blog/2019/08/27/exploiting-the-eques-elf-smart-plug-part-three/"
},
{
"trust": 1.7,
"url": "https://www.ckn.io/blog/2019/08/27/exploiting-the-eques-elf-smart-plug-part-two/"
},
{
"trust": 0.8,
"url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2019-15745"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2019-31320"
},
{
"db": "VULHUB",
"id": "VHN-147822"
},
{
"db": "JVNDB",
"id": "JVNDB-2019-008908"
},
{
"db": "CNNVD",
"id": "CNNVD-201908-2207"
},
{
"db": "NVD",
"id": "CVE-2019-15745"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "CNVD",
"id": "CNVD-2019-31320"
},
{
"db": "VULHUB",
"id": "VHN-147822"
},
{
"db": "JVNDB",
"id": "JVNDB-2019-008908"
},
{
"db": "CNNVD",
"id": "CNNVD-201908-2207"
},
{
"db": "NVD",
"id": "CVE-2019-15745"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2019-09-14T00:00:00",
"db": "CNVD",
"id": "CNVD-2019-31320"
},
{
"date": "2019-08-29T00:00:00",
"db": "VULHUB",
"id": "VHN-147822"
},
{
"date": "2019-09-09T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2019-008908"
},
{
"date": "2019-08-29T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201908-2207"
},
{
"date": "2019-08-29T13:15:11.227000",
"db": "NVD",
"id": "CVE-2019-15745"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2019-09-14T00:00:00",
"db": "CNVD",
"id": "CNVD-2019-31320"
},
{
"date": "2019-09-05T00:00:00",
"db": "VULHUB",
"id": "VHN-147822"
},
{
"date": "2019-09-09T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2019-008908"
},
{
"date": "2019-09-06T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201908-2207"
},
{
"date": "2024-11-21T04:29:23.397000",
"db": "NVD",
"id": "CVE-2019-15745"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote or local",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-201908-2207"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Eques elf Vulnerabilities related to the use of hard-coded credentials in smart plugs and mobile applications",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2019-008908"
}
],
"trust": 0.8
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "trust management problem",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-201908-2207"
}
],
"trust": 0.6
}
}