Search

Find a vulnerability

Search criteria

    4 vulnerabilities by drtrustusa

    VAR-202204-1273

    Vulnerability from variot - Updated: 2025-01-30 21:13

    Dr Trust USA iCheck Connect BP Monitor BP Testing 118 1.2.1 is vulnerable to Plain text command over BLE. (DoS) It may be in a state. No detailed vulnerability details are currently provided

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-202204-1273",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "icheck connect bp monitor bp testing 118",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "drtrustusa",
            "version": "1.2.1"
          },
          {
            "model": "icheck connect bp monitor bp testing 118",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "drtrustusa",
            "version": null
          },
          {
            "model": "icheck connect bp monitor bp testing 118",
            "scope": null,
            "trust": 0.8,
            "vendor": "drtrustusa",
            "version": null
          },
          {
            "model": "icheck connect bp monitor bp testing 118",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "drtrustusa",
            "version": "icheck connect bp monitor bp testing 118  firmware  1.2.1"
          },
          {
            "model": "trust usa icheck connect bp monitor bp testing",
            "scope": "eq",
            "trust": 0.6,
            "vendor": "dr",
            "version": "1181.2.1"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2022-33813"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-017654"
          },
          {
            "db": "NVD",
            "id": "CVE-2020-27373"
          }
        ]
      },
      "cve": "CVE-2020-27373",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "accessComplexity": "LOW",
                "accessVector": "ADJACENT_NETWORK",
                "authentication": "NONE",
                "author": "nvd@nist.gov",
                "availabilityImpact": "COMPLETE",
                "baseScore": 8.3,
                "confidentialityImpact": "COMPLETE",
                "exploitabilityScore": 6.5,
                "id": "CVE-2020-27373",
                "impactScore": 10.0,
                "integrityImpact": "COMPLETE",
                "severity": "HIGH",
                "trust": 1.8,
                "vectorString": "AV:A/AC:L/Au:N/C:C/I:C/A:C",
                "version": "2.0"
              },
              {
                "accessComplexity": "LOW",
                "accessVector": "ADJACENT_NETWORK",
                "authentication": "NONE",
                "author": "CNVD",
                "availabilityImpact": "COMPLETE",
                "baseScore": 8.3,
                "confidentialityImpact": "COMPLETE",
                "exploitabilityScore": 6.5,
                "id": "CNVD-2022-33813",
                "impactScore": 10.0,
                "integrityImpact": "COMPLETE",
                "severity": "HIGH",
                "trust": 0.6,
                "vectorString": "AV:A/AC:L/Au:N/C:C/I:C/A:C",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "ADJACENT",
                "author": "nvd@nist.gov",
                "availabilityImpact": "HIGH",
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 2.8,
                "id": "CVE-2020-27373",
                "impactScore": 5.9,
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "trust": 1.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              {
                "attackComplexity": "Low",
                "attackVector": "Adjacent Network",
                "author": "NVD",
                "availabilityImpact": "High",
                "baseScore": 8.8,
                "baseSeverity": "High",
                "confidentialityImpact": "High",
                "exploitabilityScore": null,
                "id": "CVE-2020-27373",
                "impactScore": null,
                "integrityImpact": "High",
                "privilegesRequired": "None",
                "scope": "Unchanged",
                "trust": 0.8,
                "userInteraction": "None",
                "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "nvd@nist.gov",
                "id": "CVE-2020-27373",
                "trust": 1.0,
                "value": "HIGH"
              },
              {
                "author": "NVD",
                "id": "CVE-2020-27373",
                "trust": 0.8,
                "value": "High"
              },
              {
                "author": "CNVD",
                "id": "CNVD-2022-33813",
                "trust": 0.6,
                "value": "HIGH"
              },
              {
                "author": "CNNVD",
                "id": "CNNVD-202204-2585",
                "trust": 0.6,
                "value": "HIGH"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2022-33813"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-017654"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202204-2585"
          },
          {
            "db": "NVD",
            "id": "CVE-2020-27373"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Dr Trust USA iCheck Connect BP Monitor BP Testing 118 1.2.1 is vulnerable to Plain text command over BLE. (DoS) It may be in a state. No detailed vulnerability details are currently provided",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2020-27373"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-017654"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2022-33813"
          }
        ],
        "trust": 2.16
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2020-27373",
            "trust": 3.9
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-017654",
            "trust": 0.8
          },
          {
            "db": "CNVD",
            "id": "CNVD-2022-33813",
            "trust": 0.6
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202204-2585",
            "trust": 0.6
          },
          {
            "db": "OTHER",
            "id": "NONE",
            "trust": 0.1
          }
        ],
        "sources": [
          {
            "db": "OTHER",
            "id": null
          },
          {
            "db": "CNVD",
            "id": "CNVD-2022-33813"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-017654"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202204-2585"
          },
          {
            "db": "NVD",
            "id": "CVE-2020-27373"
          }
        ]
      },
      "id": "VAR-202204-1273",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "OTHER",
            "id": null
          },
          {
            "db": "CNVD",
            "id": "CNVD-2022-33813"
          }
        ],
        "trust": 1.7
      },
      "iot_taxonomy": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "category": [
              "Network device"
            ],
            "sub_category": null,
            "trust": 0.6
          },
          {
            "category": [
              "medical device"
            ],
            "sub_category": "blood pressure monitor",
            "trust": 0.1
          }
        ],
        "sources": [
          {
            "db": "OTHER",
            "id": null
          },
          {
            "db": "CNVD",
            "id": "CNVD-2022-33813"
          }
        ]
      },
      "last_update_date": "2025-01-30T21:13:46.048000Z",
      "patch": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/patch#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "title": "Patch for Dr Trust USA iCheck Connect BP Monitor BP Testing 118 Operating System Command Injection Vulnerability",
            "trust": 0.6,
            "url": "https://www.cnvd.org.cn/patchInfo/show/331596"
          },
          {
            "title": "Dr Trust USA iCheck Connect BP Monitor BP Testing 118 Fixes for operating system command injection vulnerabilities",
            "trust": 0.6,
            "url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=189434"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2022-33813"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202204-2585"
          }
        ]
      },
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-78",
            "trust": 1.0
          },
          {
            "problemtype": "OS Command injection (CWE-78) [NVD evaluation ]",
            "trust": 0.8
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-017654"
          },
          {
            "db": "NVD",
            "id": "CVE-2020-27373"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 2.4,
            "url": "http://dr.com"
          },
          {
            "trust": 2.4,
            "url": "https://drtrust.in/collections/dr-trust-blood-pressure-testing/products/dr-trust-usa-icheck-connect-bp-monitor"
          },
          {
            "trust": 2.4,
            "url": "https://nvermaa.medium.com/cve-on-radio-technology-d-4b65efa1ba5c"
          },
          {
            "trust": 1.4,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2020-27373"
          },
          {
            "trust": 0.6,
            "url": "https://cxsecurity.com/cveshow/cve-2020-27373/"
          },
          {
            "trust": 0.1,
            "url": "https://ieeexplore.ieee.org/abstract/document/10769424"
          }
        ],
        "sources": [
          {
            "db": "OTHER",
            "id": null
          },
          {
            "db": "CNVD",
            "id": "CNVD-2022-33813"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-017654"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202204-2585"
          },
          {
            "db": "NVD",
            "id": "CVE-2020-27373"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "OTHER",
            "id": null
          },
          {
            "db": "CNVD",
            "id": "CNVD-2022-33813"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-017654"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202204-2585"
          },
          {
            "db": "NVD",
            "id": "CVE-2020-27373"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2022-05-02T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2022-33813"
          },
          {
            "date": "2023-07-21T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2020-017654"
          },
          {
            "date": "2022-04-07T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-202204-2585"
          },
          {
            "date": "2022-04-07T02:15:06.993000",
            "db": "NVD",
            "id": "CVE-2020-27373"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2022-05-02T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2022-33813"
          },
          {
            "date": "2023-07-21T08:19:00",
            "db": "JVNDB",
            "id": "JVNDB-2020-017654"
          },
          {
            "date": "2022-04-15T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-202204-2585"
          },
          {
            "date": "2022-04-14T16:35:57.267000",
            "db": "NVD",
            "id": "CVE-2020-27373"
          }
        ]
      },
      "threat_type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "remote or local",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202204-2585"
          }
        ],
        "trust": 0.6
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Dr Trust USA iCheck Connect BP Monitor BP Testing 118 Operating System Command Injection Vulnerability",
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2022-33813"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202204-2585"
          }
        ],
        "trust": 1.2
      },
      "type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "operating system commend injection",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202204-2585"
          }
        ],
        "trust": 0.6
      }
    }

    VAR-202204-0733

    Vulnerability from variot - Updated: 2024-08-14 15:01

    Dr Trust USA iCheck Connect BP Monitor BP Testing 118 1.2.1 is vulnerable to a Replay Attack to BP Monitoring. drtrustusa of icheck connect bp monitor bp testing 118 The firmware has Capture-replay An authentication bypass vulnerability exists.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. No detailed vulnerability details are currently provided

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-202204-0733",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "icheck connect bp monitor bp testing 118",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "drtrustusa",
            "version": "1.2.1"
          },
          {
            "model": "icheck connect bp monitor bp testing 118",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "drtrustusa",
            "version": null
          },
          {
            "model": "icheck connect bp monitor bp testing 118",
            "scope": null,
            "trust": 0.8,
            "vendor": "drtrustusa",
            "version": null
          },
          {
            "model": "icheck connect bp monitor bp testing 118",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "drtrustusa",
            "version": "icheck connect bp monitor bp testing 118  firmware  1.2.1"
          },
          {
            "model": "trust usa icheck connect bp monitor bp testing",
            "scope": "eq",
            "trust": 0.6,
            "vendor": "dr",
            "version": "1181.2.1"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2022-33814"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-017653"
          },
          {
            "db": "NVD",
            "id": "CVE-2020-27374"
          }
        ]
      },
      "cve": "CVE-2020-27374",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "accessComplexity": "MEDIUM",
                "accessVector": "ADJACENT_NETWORK",
                "authentication": "NONE",
                "author": "nvd@nist.gov",
                "availabilityImpact": "COMPLETE",
                "baseScore": 7.9,
                "confidentialityImpact": "COMPLETE",
                "exploitabilityScore": 5.5,
                "id": "CVE-2020-27374",
                "impactScore": 10.0,
                "integrityImpact": "COMPLETE",
                "severity": "HIGH",
                "trust": 1.8,
                "vectorString": "AV:A/AC:M/Au:N/C:C/I:C/A:C",
                "version": "2.0"
              },
              {
                "accessComplexity": "MEDIUM",
                "accessVector": "ADJACENT_NETWORK",
                "authentication": "NONE",
                "author": "CNVD",
                "availabilityImpact": "COMPLETE",
                "baseScore": 7.9,
                "confidentialityImpact": "COMPLETE",
                "exploitabilityScore": 5.5,
                "id": "CNVD-2022-33814",
                "impactScore": 10.0,
                "integrityImpact": "COMPLETE",
                "severity": "HIGH",
                "trust": 0.6,
                "vectorString": "AV:A/AC:M/Au:N/C:C/I:C/A:C",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "HIGH",
                "attackVector": "ADJACENT",
                "author": "nvd@nist.gov",
                "availabilityImpact": "HIGH",
                "baseScore": 7.5,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 1.6,
                "id": "CVE-2020-27374",
                "impactScore": 5.9,
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "trust": 1.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:A/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              {
                "attackComplexity": "High",
                "attackVector": "Adjacent Network",
                "author": "NVD",
                "availabilityImpact": "High",
                "baseScore": 7.5,
                "baseSeverity": "High",
                "confidentialityImpact": "High",
                "exploitabilityScore": null,
                "id": "CVE-2020-27374",
                "impactScore": null,
                "integrityImpact": "High",
                "privilegesRequired": "None",
                "scope": "Unchanged",
                "trust": 0.8,
                "userInteraction": "None",
                "vectorString": "CVSS:3.0/AV:A/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "nvd@nist.gov",
                "id": "CVE-2020-27374",
                "trust": 1.0,
                "value": "HIGH"
              },
              {
                "author": "NVD",
                "id": "CVE-2020-27374",
                "trust": 0.8,
                "value": "High"
              },
              {
                "author": "CNVD",
                "id": "CNVD-2022-33814",
                "trust": 0.6,
                "value": "HIGH"
              },
              {
                "author": "CNNVD",
                "id": "CNNVD-202204-2584",
                "trust": 0.6,
                "value": "HIGH"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2022-33814"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-017653"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202204-2584"
          },
          {
            "db": "NVD",
            "id": "CVE-2020-27374"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Dr Trust USA iCheck Connect BP Monitor BP Testing 118 1.2.1 is vulnerable to a Replay Attack to BP Monitoring. drtrustusa of icheck connect bp monitor bp testing 118 The firmware has Capture-replay An authentication bypass vulnerability exists.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. No detailed vulnerability details are currently provided",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2020-27374"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-017653"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2022-33814"
          }
        ],
        "trust": 2.16
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2020-27374",
            "trust": 3.8
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-017653",
            "trust": 0.8
          },
          {
            "db": "CNVD",
            "id": "CNVD-2022-33814",
            "trust": 0.6
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202204-2584",
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2022-33814"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-017653"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202204-2584"
          },
          {
            "db": "NVD",
            "id": "CVE-2020-27374"
          }
        ]
      },
      "id": "VAR-202204-0733",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2022-33814"
          }
        ],
        "trust": 1.6
      },
      "iot_taxonomy": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "category": [
              "Network device"
            ],
            "sub_category": null,
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2022-33814"
          }
        ]
      },
      "last_update_date": "2024-08-14T15:01:04.889000Z",
      "patch": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/patch#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "title": "Patch for Dr Trust USA iCheck Connect BP Monitor BP Testing 118 Has Unknown Vulnerability",
            "trust": 0.6,
            "url": "https://www.cnvd.org.cn/patchInfo/show/331591"
          },
          {
            "title": "Dr Trust USA iCheck Connect BP Monitor BP Testing 118 Security vulnerabilities",
            "trust": 0.6,
            "url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=189433"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2022-33814"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202204-2584"
          }
        ]
      },
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-294",
            "trust": 1.0
          },
          {
            "problemtype": "Capture-replay authentication evasion by (CWE-294) [NVD evaluation ]",
            "trust": 0.8
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-017653"
          },
          {
            "db": "NVD",
            "id": "CVE-2020-27374"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 2.4,
            "url": "http://dr.com"
          },
          {
            "trust": 2.4,
            "url": "https://drtrust.in/collections/dr-trust-blood-pressure-testing/products/dr-trust-usa-icheck-connect-bp-monitor"
          },
          {
            "trust": 2.4,
            "url": "https://nvermaa.medium.com/cve-on-radio-technology-d-4b65efa1ba5c"
          },
          {
            "trust": 1.4,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2020-27374"
          },
          {
            "trust": 0.6,
            "url": "https://cxsecurity.com/cveshow/cve-2020-27374/"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2022-33814"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-017653"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202204-2584"
          },
          {
            "db": "NVD",
            "id": "CVE-2020-27374"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "CNVD",
            "id": "CNVD-2022-33814"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-017653"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202204-2584"
          },
          {
            "db": "NVD",
            "id": "CVE-2020-27374"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2022-05-02T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2022-33814"
          },
          {
            "date": "2023-07-21T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2020-017653"
          },
          {
            "date": "2022-04-07T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-202204-2584"
          },
          {
            "date": "2022-04-07T02:15:07.050000",
            "db": "NVD",
            "id": "CVE-2020-27374"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2022-05-02T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2022-33814"
          },
          {
            "date": "2023-07-21T08:19:00",
            "db": "JVNDB",
            "id": "JVNDB-2020-017653"
          },
          {
            "date": "2022-04-15T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-202204-2584"
          },
          {
            "date": "2022-04-14T16:47:26.920000",
            "db": "NVD",
            "id": "CVE-2020-27374"
          }
        ]
      },
      "threat_type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "remote or local",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202204-2584"
          }
        ],
        "trust": 0.6
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "drtrustusa\u00a0 of \u00a0icheck\u00a0connect\u00a0bp\u00a0monitor\u00a0bp\u00a0testing\u00a0118\u00a0 in the firmware \u00a0Capture-replay\u00a0 Authentication Bypass Vulnerability",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-017653"
          }
        ],
        "trust": 0.8
      },
      "type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "other",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202204-2584"
          }
        ],
        "trust": 0.6
      }
    }

    VAR-202204-1678

    Vulnerability from variot - Updated: 2024-08-14 14:31

    Dr Trust USA iCheck Connect BP Monitor BP Testing 118 version 1.2.1 is vulnerable to Missing Authentication. (DoS) It may be in a state

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-202204-1678",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "icheck connect bp monitor bp testing 118",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "drtrustusa",
            "version": "1.2.1"
          },
          {
            "model": "icheck connect bp monitor bp testing 118",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "drtrustusa",
            "version": null
          },
          {
            "model": "icheck connect bp monitor bp testing 118",
            "scope": null,
            "trust": 0.8,
            "vendor": "drtrustusa",
            "version": null
          },
          {
            "model": "icheck connect bp monitor bp testing 118",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "drtrustusa",
            "version": "icheck connect bp monitor bp testing 118  firmware  1.2.1"
          },
          {
            "model": "trust usa icheck connect bp monitor bp testing",
            "scope": "eq",
            "trust": 0.6,
            "vendor": "dr",
            "version": "1181.2.1"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2022-33816"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-017651"
          },
          {
            "db": "NVD",
            "id": "CVE-2020-27376"
          }
        ]
      },
      "cve": "CVE-2020-27376",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "accessComplexity": "LOW",
                "accessVector": "ADJACENT_NETWORK",
                "authentication": "NONE",
                "author": "nvd@nist.gov",
                "availabilityImpact": "COMPLETE",
                "baseScore": 8.3,
                "confidentialityImpact": "COMPLETE",
                "exploitabilityScore": 6.5,
                "id": "CVE-2020-27376",
                "impactScore": 10.0,
                "integrityImpact": "COMPLETE",
                "severity": "HIGH",
                "trust": 1.8,
                "vectorString": "AV:A/AC:L/Au:N/C:C/I:C/A:C",
                "version": "2.0"
              },
              {
                "accessComplexity": "LOW",
                "accessVector": "ADJACENT_NETWORK",
                "authentication": "NONE",
                "author": "CNVD",
                "availabilityImpact": "COMPLETE",
                "baseScore": 8.3,
                "confidentialityImpact": "COMPLETE",
                "exploitabilityScore": 6.5,
                "id": "CNVD-2022-33816",
                "impactScore": 10.0,
                "integrityImpact": "COMPLETE",
                "severity": "HIGH",
                "trust": 0.6,
                "vectorString": "AV:A/AC:L/Au:N/C:C/I:C/A:C",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "ADJACENT",
                "author": "nvd@nist.gov",
                "availabilityImpact": "HIGH",
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 2.8,
                "id": "CVE-2020-27376",
                "impactScore": 5.9,
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "trust": 1.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              {
                "attackComplexity": "Low",
                "attackVector": "Adjacent Network",
                "author": "NVD",
                "availabilityImpact": "High",
                "baseScore": 8.8,
                "baseSeverity": "High",
                "confidentialityImpact": "High",
                "exploitabilityScore": null,
                "id": "CVE-2020-27376",
                "impactScore": null,
                "integrityImpact": "High",
                "privilegesRequired": "None",
                "scope": "Unchanged",
                "trust": 0.8,
                "userInteraction": "None",
                "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "nvd@nist.gov",
                "id": "CVE-2020-27376",
                "trust": 1.0,
                "value": "HIGH"
              },
              {
                "author": "NVD",
                "id": "CVE-2020-27376",
                "trust": 0.8,
                "value": "High"
              },
              {
                "author": "CNVD",
                "id": "CNVD-2022-33816",
                "trust": 0.6,
                "value": "HIGH"
              },
              {
                "author": "CNNVD",
                "id": "CNNVD-202204-2582",
                "trust": 0.6,
                "value": "HIGH"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2022-33816"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-017651"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202204-2582"
          },
          {
            "db": "NVD",
            "id": "CVE-2020-27376"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Dr Trust USA iCheck Connect BP Monitor BP Testing 118 version 1.2.1 is vulnerable to Missing Authentication. (DoS) It may be in a state",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2020-27376"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-017651"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2022-33816"
          }
        ],
        "trust": 2.16
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2020-27376",
            "trust": 3.8
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-017651",
            "trust": 0.8
          },
          {
            "db": "CNVD",
            "id": "CNVD-2022-33816",
            "trust": 0.6
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202204-2582",
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2022-33816"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-017651"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202204-2582"
          },
          {
            "db": "NVD",
            "id": "CVE-2020-27376"
          }
        ]
      },
      "id": "VAR-202204-1678",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2022-33816"
          }
        ],
        "trust": 1.6
      },
      "iot_taxonomy": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "category": [
              "Network device"
            ],
            "sub_category": null,
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2022-33816"
          }
        ]
      },
      "last_update_date": "2024-08-14T14:31:13.177000Z",
      "patch": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/patch#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "title": "Patch for Dr Trust USA iCheck Connect BP Monitor BP Testing 118 Access Control Error Vulnerability",
            "trust": 0.6,
            "url": "https://www.cnvd.org.cn/patchInfo/show/331581"
          },
          {
            "title": "Dr Trust USA iCheck Connect BP Monitor BP Testing 118 Fixes for access control error vulnerabilities",
            "trust": 0.6,
            "url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=189431"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2022-33816"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202204-2582"
          }
        ]
      },
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-306",
            "trust": 1.0
          },
          {
            "problemtype": "Lack of authentication for critical features (CWE-306) [NVD evaluation ]",
            "trust": 0.8
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-017651"
          },
          {
            "db": "NVD",
            "id": "CVE-2020-27376"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 2.4,
            "url": "http://dr.com"
          },
          {
            "trust": 2.4,
            "url": "https://drtrust.in/collections/dr-trust-blood-pressure-testing/products/dr-trust-usa-icheck-connect-bp-monitor"
          },
          {
            "trust": 2.4,
            "url": "https://nvermaa.medium.com/cve-on-radio-technology-d-4b65efa1ba5c"
          },
          {
            "trust": 1.4,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2020-27376"
          },
          {
            "trust": 0.6,
            "url": "https://cxsecurity.com/cveshow/cve-2020-27376/"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2022-33816"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-017651"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202204-2582"
          },
          {
            "db": "NVD",
            "id": "CVE-2020-27376"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "CNVD",
            "id": "CNVD-2022-33816"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-017651"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202204-2582"
          },
          {
            "db": "NVD",
            "id": "CVE-2020-27376"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2022-05-02T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2022-33816"
          },
          {
            "date": "2023-07-21T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2020-017651"
          },
          {
            "date": "2022-04-07T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-202204-2582"
          },
          {
            "date": "2022-04-07T02:15:07.137000",
            "db": "NVD",
            "id": "CVE-2020-27376"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2022-05-02T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2022-33816"
          },
          {
            "date": "2023-07-21T08:19:00",
            "db": "JVNDB",
            "id": "JVNDB-2020-017651"
          },
          {
            "date": "2022-04-15T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-202204-2582"
          },
          {
            "date": "2022-04-14T18:59:47.763000",
            "db": "NVD",
            "id": "CVE-2020-27376"
          }
        ]
      },
      "threat_type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "remote or local",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202204-2582"
          }
        ],
        "trust": 0.6
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Dr Trust USA iCheck Connect BP Monitor BP Testing 118 Access Control Error Vulnerability",
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2022-33816"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202204-2582"
          }
        ],
        "trust": 1.2
      },
      "type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "access control error",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202204-2582"
          }
        ],
        "trust": 0.6
      }
    }

    VAR-202204-1677

    Vulnerability from variot - Updated: 2024-08-14 14:24

    Dr Trust USA iCheck Connect BP Monitor BP Testing 118 version 1.2.1 is vulnerable to Transmitting Write Requests and Chars

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-202204-1677",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "icheck connect bp monitor bp testing 118",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "drtrustusa",
            "version": "1.2.1"
          },
          {
            "model": "icheck connect bp monitor bp testing 118",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "drtrustusa",
            "version": null
          },
          {
            "model": "icheck connect bp monitor bp testing 118",
            "scope": null,
            "trust": 0.8,
            "vendor": "drtrustusa",
            "version": null
          },
          {
            "model": "icheck connect bp monitor bp testing 118",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "drtrustusa",
            "version": "icheck connect bp monitor bp testing 118  firmware  1.2.1"
          },
          {
            "model": "trust usa icheck connect bp monitor bp testing",
            "scope": "eq",
            "trust": 0.6,
            "vendor": "dr",
            "version": "1181.2.1"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2022-33815"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-017652"
          },
          {
            "db": "NVD",
            "id": "CVE-2020-27375"
          }
        ]
      },
      "cve": "CVE-2020-27375",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "accessComplexity": "LOW",
                "accessVector": "ADJACENT_NETWORK",
                "authentication": "NONE",
                "author": "nvd@nist.gov",
                "availabilityImpact": "NONE",
                "baseScore": 3.3,
                "confidentialityImpact": "NONE",
                "exploitabilityScore": 6.5,
                "id": "CVE-2020-27375",
                "impactScore": 2.9,
                "integrityImpact": "PARTIAL",
                "severity": "LOW",
                "trust": 1.8,
                "vectorString": "AV:A/AC:L/Au:N/C:N/I:P/A:N",
                "version": "2.0"
              },
              {
                "accessComplexity": "LOW",
                "accessVector": "ADJACENT_NETWORK",
                "authentication": "NONE",
                "author": "CNVD",
                "availabilityImpact": "NONE",
                "baseScore": 3.3,
                "confidentialityImpact": "NONE",
                "exploitabilityScore": 6.5,
                "id": "CNVD-2022-33815",
                "impactScore": 2.9,
                "integrityImpact": "PARTIAL",
                "severity": "LOW",
                "trust": 0.6,
                "vectorString": "AV:A/AC:L/Au:N/C:N/I:P/A:N",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "ADJACENT",
                "author": "nvd@nist.gov",
                "availabilityImpact": "NONE",
                "baseScore": 6.5,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "NONE",
                "exploitabilityScore": 2.8,
                "id": "CVE-2020-27375",
                "impactScore": 3.6,
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "trust": 1.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N",
                "version": "3.1"
              },
              {
                "attackComplexity": "Low",
                "attackVector": "Adjacent Network",
                "author": "NVD",
                "availabilityImpact": "None",
                "baseScore": 6.5,
                "baseSeverity": "Medium",
                "confidentialityImpact": "None",
                "exploitabilityScore": null,
                "id": "CVE-2020-27375",
                "impactScore": null,
                "integrityImpact": "High",
                "privilegesRequired": "None",
                "scope": "Unchanged",
                "trust": 0.8,
                "userInteraction": "None",
                "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "nvd@nist.gov",
                "id": "CVE-2020-27375",
                "trust": 1.0,
                "value": "MEDIUM"
              },
              {
                "author": "NVD",
                "id": "CVE-2020-27375",
                "trust": 0.8,
                "value": "Medium"
              },
              {
                "author": "CNVD",
                "id": "CNVD-2022-33815",
                "trust": 0.6,
                "value": "LOW"
              },
              {
                "author": "CNNVD",
                "id": "CNNVD-202204-2583",
                "trust": 0.6,
                "value": "MEDIUM"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2022-33815"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-017652"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202204-2583"
          },
          {
            "db": "NVD",
            "id": "CVE-2020-27375"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Dr Trust USA iCheck Connect BP Monitor BP Testing 118 version 1.2.1 is vulnerable to Transmitting Write Requests and Chars",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2020-27375"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-017652"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2022-33815"
          }
        ],
        "trust": 2.16
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2020-27375",
            "trust": 3.8
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-017652",
            "trust": 0.8
          },
          {
            "db": "CNVD",
            "id": "CNVD-2022-33815",
            "trust": 0.6
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202204-2583",
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2022-33815"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-017652"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202204-2583"
          },
          {
            "db": "NVD",
            "id": "CVE-2020-27375"
          }
        ]
      },
      "id": "VAR-202204-1677",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2022-33815"
          }
        ],
        "trust": 1.6
      },
      "iot_taxonomy": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "category": [
              "Network device"
            ],
            "sub_category": null,
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2022-33815"
          }
        ]
      },
      "last_update_date": "2024-08-14T14:24:50.388000Z",
      "patch": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/patch#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "title": "Patch for Dr Trust USA iCheck Connect BP Monitor BP Testing 118 Code Issue Vulnerability",
            "trust": 0.6,
            "url": "https://www.cnvd.org.cn/patchInfo/show/331586"
          },
          {
            "title": "Dr Trust USA iCheck Connect BP Monitor BP Testing 118 Fixes for code issue vulnerabilities",
            "trust": 0.6,
            "url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=189432"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2022-33815"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202204-2583"
          }
        ]
      },
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-918",
            "trust": 1.0
          },
          {
            "problemtype": "Server-side request forgery (CWE-918) [NVD evaluation ]",
            "trust": 0.8
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-017652"
          },
          {
            "db": "NVD",
            "id": "CVE-2020-27375"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 2.4,
            "url": "http://dr.com"
          },
          {
            "trust": 2.4,
            "url": "https://drtrust.in/collections/dr-trust-blood-pressure-testing/products/dr-trust-usa-icheck-connect-bp-monitor"
          },
          {
            "trust": 2.4,
            "url": "https://nvermaa.medium.com/cve-on-radio-technology-d-4b65efa1ba5c"
          },
          {
            "trust": 1.4,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2020-27375"
          },
          {
            "trust": 0.6,
            "url": "https://cxsecurity.com/cveshow/cve-2020-27375/"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2022-33815"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-017652"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202204-2583"
          },
          {
            "db": "NVD",
            "id": "CVE-2020-27375"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "CNVD",
            "id": "CNVD-2022-33815"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-017652"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202204-2583"
          },
          {
            "db": "NVD",
            "id": "CVE-2020-27375"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2022-05-02T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2022-33815"
          },
          {
            "date": "2023-07-21T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2020-017652"
          },
          {
            "date": "2022-04-07T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-202204-2583"
          },
          {
            "date": "2022-04-07T02:15:07.093000",
            "db": "NVD",
            "id": "CVE-2020-27375"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2022-05-02T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2022-33815"
          },
          {
            "date": "2023-07-21T08:19:00",
            "db": "JVNDB",
            "id": "JVNDB-2020-017652"
          },
          {
            "date": "2022-04-15T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-202204-2583"
          },
          {
            "date": "2022-04-14T18:59:05.810000",
            "db": "NVD",
            "id": "CVE-2020-27375"
          }
        ]
      },
      "threat_type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "remote or local",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202204-2583"
          }
        ],
        "trust": 0.6
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "drtrustusa\u00a0 of \u00a0icheck\u00a0connect\u00a0bp\u00a0monitor\u00a0bp\u00a0testing\u00a0118\u00a0 Server-side request forgery vulnerability in firmware",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-017652"
          }
        ],
        "trust": 0.8
      },
      "type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "code problem",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202204-2583"
          }
        ],
        "trust": 0.6
      }
    }