CVE-2026-1816 (GCVE-0-2026-1816)

Vulnerability from cvelistv5 – Published: 2026-05-21 14:08 – Updated: 2026-05-21 14:32
VLAI
Title
OTP Bypass in TEİAŞ's Mobile Application
Summary
Improper restriction of excessive authentication attempts vulnerability in Turkiye Electricity Transmission Corporation (TEİAŞ) Mobile Application allows Brute Force. This issue affects Mobile Application: from 1.6.2 before 1.13.
CWE
  • CWE-307 - Improper restriction of excessive authentication attempts
Assigner
References
Impacted products
Date Public
2026-05-21 13:59
Credits
Metin ÖGTEM
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2026-1816",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-05-21T14:32:32.195470Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-05-21T14:32:45.765Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Mobile Application",
          "vendor": "Turkiye Electricity Transmission Corporation (TE\u0130A\u015e)",
          "versions": [
            {
              "lessThan": "1.13",
              "status": "affected",
              "version": "1.6.2",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Metin \u00d6GTEM"
        }
      ],
      "datePublic": "2026-05-21T13:59:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Improper restriction of excessive authentication attempts vulnerability in Turkiye Electricity Transmission Corporation (TE\u0130A\u015e) Mobile Application allows Brute Force.\u003cp\u003eThis issue affects Mobile Application: from 1.6.2 before 1.13.\u003c/p\u003e"
            }
          ],
          "value": "Improper restriction of excessive authentication attempts vulnerability in Turkiye Electricity Transmission Corporation (TE\u0130A\u015e) Mobile Application allows Brute Force.\n\nThis issue affects Mobile Application: from 1.6.2 before 1.13."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-112",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-112 Brute Force"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 6.3,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "LOW",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:U/C:H/I:L/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-307",
              "description": "CWE-307 Improper restriction of excessive authentication attempts",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-05-21T14:08:15.591Z",
        "orgId": "ca940d4e-fea4-4aa2-9a58-591a58b1ce21",
        "shortName": "TR-CERT"
      },
      "references": [
        {
          "tags": [
            "government-resource"
          ],
          "url": "https://siberguvenlik.gov.tr/guvenlik-bildirimleri/detay/tr-26-0286"
        }
      ],
      "source": {
        "advisory": "TR-26-0286",
        "defect": [
          "TR-26-0286"
        ],
        "discovery": "UNKNOWN"
      },
      "title": "OTP Bypass in TE\u0130A\u015e\u0027s Mobile Application",
      "x_generator": {
        "engine": "Vulnogram 1.0.2"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "ca940d4e-fea4-4aa2-9a58-591a58b1ce21",
    "assignerShortName": "TR-CERT",
    "cveId": "CVE-2026-1816",
    "datePublished": "2026-05-21T14:08:15.591Z",
    "dateReserved": "2026-02-03T14:06:50.593Z",
    "dateUpdated": "2026-05-21T14:32:45.765Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2026-1815 (GCVE-0-2026-1815)

Vulnerability from cvelistv5 – Published: 2026-05-21 13:56 – Updated: 2026-05-21 14:38
VLAI
Title
Session Hijacking in TEİAŞ's Mobile Application
Summary
Insufficient session expiration vulnerability in Turkiye Electricity Transmission Corporation (TEİAŞ) Mobile Application allows Session Hijacking. This issue affects Mobile Application: from 1.6.2 before 1.13.
CWE
  • CWE-613 - Insufficient session expiration
Assigner
References
Impacted products
Date Public
2026-05-21 13:42
Credits
Metin ÖGTEM
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2026-1815",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-05-21T14:37:42.223719Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-05-21T14:38:08.702Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Mobile Application",
          "vendor": "Turkiye Electricity Transmission Corporation (TE\u0130A\u015e)",
          "versions": [
            {
              "lessThan": "1.13",
              "status": "affected",
              "version": "1.6.2",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Metin \u00d6GTEM"
        }
      ],
      "datePublic": "2026-05-21T13:42:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Insufficient session expiration vulnerability in Turkiye Electricity Transmission Corporation (TE\u0130A\u015e) Mobile Application allows Session Hijacking.\u003cp\u003eThis issue affects Mobile Application: from 1.6.2 before 1.13.\u003c/p\u003e"
            }
          ],
          "value": "Insufficient session expiration vulnerability in Turkiye Electricity Transmission Corporation (TE\u0130A\u015e) Mobile Application allows Session Hijacking.\n\nThis issue affects Mobile Application: from 1.6.2 before 1.13."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-593",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-593 Session Hijacking"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 5.7,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "NONE",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:U/C:H/I:N/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-613",
              "description": "CWE-613 Insufficient session expiration",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-05-21T13:58:23.167Z",
        "orgId": "ca940d4e-fea4-4aa2-9a58-591a58b1ce21",
        "shortName": "TR-CERT"
      },
      "references": [
        {
          "tags": [
            "government-resource"
          ],
          "url": "https://siberguvenlik.gov.tr/guvenlik-bildirimleri/detay/tr-26-0286"
        }
      ],
      "source": {
        "advisory": "TR-26-0286",
        "defect": [
          "TR-26-0286"
        ],
        "discovery": "UNKNOWN"
      },
      "title": "Session Hijacking in TE\u0130A\u015e\u0027s Mobile Application",
      "x_generator": {
        "engine": "Vulnogram 1.0.2"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "ca940d4e-fea4-4aa2-9a58-591a58b1ce21",
    "assignerShortName": "TR-CERT",
    "cveId": "CVE-2026-1815",
    "datePublished": "2026-05-21T13:56:16.733Z",
    "dateReserved": "2026-02-03T14:06:49.089Z",
    "dateUpdated": "2026-05-21T14:38:08.702Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}