6 vulnerabilities by Technostrobe
CVE-2026-5574 (GCVE-0-2026-5574)
Vulnerability from cvelistv5 – Published: 2026-04-05 14:45 – Updated: 2026-04-06 16:16
VLAI?
Title
Technostrobe HI-LED-WR120-G2 FsBrowseClean deletefile authorization
Summary
A security vulnerability has been detected in Technostrobe HI-LED-WR120-G2 5.5.0.1R6.03.30. Affected is the function deletefile of the component FsBrowseClean. The manipulation of the argument dir/path leads to missing authorization. The attack may be initiated remotely. The exploit has been disclosed publicly and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
Severity ?
Assigner
References
| URL | Tags | |||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Technostrobe | HI-LED-WR120-G2 |
Affected:
5.5.0.1R6.03.30
|
Credits
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-5574",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-04-06T16:16:39.703086Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-04-06T16:16:52.463Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"modules": [
"FsBrowseClean"
],
"product": "HI-LED-WR120-G2",
"vendor": "Technostrobe",
"versions": [
{
"status": "affected",
"version": "5.5.0.1R6.03.30"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "shiky8 (VulDB User)"
},
{
"lang": "en",
"type": "coordinator",
"value": "VulDB CNA Team"
}
],
"descriptions": [
{
"lang": "en",
"value": "A security vulnerability has been detected in Technostrobe HI-LED-WR120-G2 5.5.0.1R6.03.30. Affected is the function deletefile of the component FsBrowseClean. The manipulation of the argument dir/path leads to missing authorization. The attack may be initiated remotely. The exploit has been disclosed publicly and may be used. The vendor was contacted early about this disclosure but did not respond in any way."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 6.9,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:L/VA:L/SC:N/SI:N/SA:N/E:P",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:L/E:P/RL:X/RC:R",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:L/E:P/RL:X/RC:R",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 6.4,
"vectorString": "AV:N/AC:L/Au:N/C:N/I:P/A:P/E:POC/RL:ND/RC:UR",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-862",
"description": "Missing Authorization",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-863",
"description": "Incorrect Authorization",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-04-05T14:45:12.224Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-355344 | Technostrobe HI-LED-WR120-G2 FsBrowseClean deletefile authorization",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/vuln/355344"
},
{
"name": "VDB-355344 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/vuln/355344/cti"
},
{
"name": "Submit #783327 | Technostrobe HI-LED-WR120-G2 Obstruction Lighting Controller 5.5.0.1R6.03.30 Improper Access Control for Unauthenticated File Deletion",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/submit/783327"
},
{
"tags": [
"exploit"
],
"url": "https://github.com/shiky8/my--cve-vulnerability-research/blob/main/my_VulnDB_cves/CVE-TECHNOSTROBE-06-FileDeletion.md"
}
],
"timeline": [
{
"lang": "en",
"time": "2026-04-04T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2026-04-04T02:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2026-04-04T16:46:40.000Z",
"value": "VulDB entry last update"
}
],
"title": "Technostrobe HI-LED-WR120-G2 FsBrowseClean deletefile authorization"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2026-5574",
"datePublished": "2026-04-05T14:45:12.224Z",
"dateReserved": "2026-04-04T14:41:18.833Z",
"dateUpdated": "2026-04-06T16:16:52.463Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-5573 (GCVE-0-2026-5573)
Vulnerability from cvelistv5 – Published: 2026-04-05 14:30 – Updated: 2026-04-06 18:05
VLAI?
Title
Technostrobe HI-LED-WR120-G2 fs unrestricted upload
Summary
A weakness has been identified in Technostrobe HI-LED-WR120-G2 5.5.0.1R6.03.30. This impacts an unknown function of the file /fs. Executing a manipulation of the argument cwd can lead to unrestricted upload. The attack can be launched remotely. The exploit has been made available to the public and could be used for attacks. The vendor was contacted early about this disclosure but did not respond in any way.
Severity ?
Assigner
References
| URL | Tags | |||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Technostrobe | HI-LED-WR120-G2 |
Affected:
5.5.0.1R6.03.30
|
Credits
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-5573",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-04-06T18:05:39.982541Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-04-06T18:05:52.840Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "HI-LED-WR120-G2",
"vendor": "Technostrobe",
"versions": [
{
"status": "affected",
"version": "5.5.0.1R6.03.30"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "shiky8 (VulDB User)"
},
{
"lang": "en",
"type": "coordinator",
"value": "VulDB CNA Team"
}
],
"descriptions": [
{
"lang": "en",
"value": "A weakness has been identified in Technostrobe HI-LED-WR120-G2 5.5.0.1R6.03.30. This impacts an unknown function of the file /fs. Executing a manipulation of the argument cwd can lead to unrestricted upload. The attack can be launched remotely. The exploit has been made available to the public and could be used for attacks. The vendor was contacted early about this disclosure but did not respond in any way."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 6.9,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N/E:P",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 7.3,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L/E:P/RL:X/RC:R",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 7.3,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L/E:P/RL:X/RC:R",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 7.5,
"vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P/E:POC/RL:ND/RC:UR",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-434",
"description": "Unrestricted Upload",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-284",
"description": "Improper Access Controls",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-04-05T14:30:14.217Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-355343 | Technostrobe HI-LED-WR120-G2 fs unrestricted upload",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/vuln/355343"
},
{
"name": "VDB-355343 | CTI Indicators (IOB, IOC, TTP, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/vuln/355343/cti"
},
{
"name": "Submit #783326 | Technostrobe HI-LED-WR120-G2 Obstruction Lighting Controller 5.5.0.1R6.03.30 Unrestricted File Upload",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/submit/783326"
},
{
"tags": [
"exploit"
],
"url": "https://github.com/shiky8/my--cve-vulnerability-research/blob/main/my_VulnDB_cves/CVE-TECHNOSTROBE-05-FileUpload.md"
}
],
"timeline": [
{
"lang": "en",
"time": "2026-04-04T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2026-04-04T02:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2026-04-04T16:46:37.000Z",
"value": "VulDB entry last update"
}
],
"title": "Technostrobe HI-LED-WR120-G2 fs unrestricted upload"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2026-5573",
"datePublished": "2026-04-05T14:30:14.217Z",
"dateReserved": "2026-04-04T14:41:15.498Z",
"dateUpdated": "2026-04-06T18:05:52.840Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-5572 (GCVE-0-2026-5572)
Vulnerability from cvelistv5 – Published: 2026-04-05 14:00 – Updated: 2026-04-06 14:50
VLAI?
Title
Technostrobe HI-LED-WR120-G2 cross-site request forgery
Summary
A security flaw has been discovered in Technostrobe HI-LED-WR120-G2 5.5.0.1R6.03.30. This affects an unknown function. Performing a manipulation results in cross-site request forgery. The attack can be initiated remotely. The exploit has been released to the public and may be used for attacks. The vendor was contacted early about this disclosure but did not respond in any way.
Severity ?
Assigner
References
| URL | Tags | |||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Technostrobe | HI-LED-WR120-G2 |
Affected:
5.5.0.1R6.03.30
|
Credits
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-5572",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-04-06T14:46:35.004535Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-04-06T14:50:35.442Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "HI-LED-WR120-G2",
"vendor": "Technostrobe",
"versions": [
{
"status": "affected",
"version": "5.5.0.1R6.03.30"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "shiky8 (VulDB User)"
},
{
"lang": "en",
"type": "coordinator",
"value": "VulDB CNA Team"
}
],
"descriptions": [
{
"lang": "en",
"value": "A security flaw has been discovered in Technostrobe HI-LED-WR120-G2 5.5.0.1R6.03.30. This affects an unknown function. Performing a manipulation results in cross-site request forgery. The attack can be initiated remotely. The exploit has been released to the public and may be used for attacks. The vendor was contacted early about this disclosure but did not respond in any way."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:P/VC:N/VI:L/VA:N/SC:N/SI:N/SA:N/E:P",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 4.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:L/A:N/E:P/RL:X/RC:R",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 4.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:L/A:N/E:P/RL:X/RC:R",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 5,
"vectorString": "AV:N/AC:L/Au:N/C:N/I:P/A:N/E:POC/RL:ND/RC:UR",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-352",
"description": "Cross-Site Request Forgery",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-862",
"description": "Missing Authorization",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-04-05T14:00:18.156Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-355342 | Technostrobe HI-LED-WR120-G2 cross-site request forgery",
"tags": [
"vdb-entry"
],
"url": "https://vuldb.com/vuln/355342"
},
{
"name": "VDB-355342 | CTI Indicators (IOB, IOC)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/vuln/355342/cti"
},
{
"name": "Submit #783325 | Technostrobe HI-LED-WR120-G2 Obstruction Lighting Controller 5.5.0.1R6.03.30 Cross-Site Request Forgery (CSRF)",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/submit/783325"
},
{
"tags": [
"exploit"
],
"url": "https://github.com/shiky8/my--cve-vulnerability-research/blob/main/my_VulnDB_cves/CVE-TECHNOSTROBE-04-CSRF.md"
}
],
"timeline": [
{
"lang": "en",
"time": "2026-04-04T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2026-04-04T02:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2026-04-04T16:46:34.000Z",
"value": "VulDB entry last update"
}
],
"title": "Technostrobe HI-LED-WR120-G2 cross-site request forgery"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2026-5572",
"datePublished": "2026-04-05T14:00:18.156Z",
"dateReserved": "2026-04-04T14:41:11.268Z",
"dateUpdated": "2026-04-06T14:50:35.442Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-5571 (GCVE-0-2026-5571)
Vulnerability from cvelistv5 – Published: 2026-04-05 13:45 – Updated: 2026-04-06 15:27
VLAI?
Title
Technostrobe HI-LED-WR120-G2 Configuration Data fs information disclosure
Summary
A vulnerability was identified in Technostrobe HI-LED-WR120-G2 5.5.0.1R6.03.30. The impacted element is an unknown function of the file /fs of the component Configuration Data Handler. Such manipulation of the argument File leads to information disclosure. It is possible to launch the attack remotely. The exploit is publicly available and might be used. The vendor was contacted early about this disclosure but did not respond in any way.
Severity ?
Assigner
References
| URL | Tags | |||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Technostrobe | HI-LED-WR120-G2 |
Affected:
5.5.0.1R6.03.30
|
Credits
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-5571",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-04-06T15:26:59.466633Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-04-06T15:27:09.752Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"modules": [
"Configuration Data Handler"
],
"product": "HI-LED-WR120-G2",
"vendor": "Technostrobe",
"versions": [
{
"status": "affected",
"version": "5.5.0.1R6.03.30"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "shiky8 (VulDB User)"
},
{
"lang": "en",
"type": "coordinator",
"value": "VulDB CNA Team"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability was identified in Technostrobe HI-LED-WR120-G2 5.5.0.1R6.03.30. The impacted element is an unknown function of the file /fs of the component Configuration Data Handler. Such manipulation of the argument File leads to information disclosure. It is possible to launch the attack remotely. The exploit is publicly available and might be used. The vendor was contacted early about this disclosure but did not respond in any way."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 6.9,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:L/VI:N/VA:N/SC:N/SI:N/SA:N/E:P",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N/E:P/RL:X/RC:R",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N/E:P/RL:X/RC:R",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 5,
"vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N/E:POC/RL:ND/RC:UR",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-200",
"description": "Information Disclosure",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-284",
"description": "Improper Access Controls",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-04-05T13:45:10.700Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-355341 | Technostrobe HI-LED-WR120-G2 Configuration Data fs information disclosure",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/vuln/355341"
},
{
"name": "VDB-355341 | CTI Indicators (IOB, IOC, TTP, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/vuln/355341/cti"
},
{
"name": "Submit #783324 | Technostrobe HI-LED-WR120-G2 Obstruction Lighting Controller 5.5.0.1R6.03.30 Information Disclosure",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/submit/783324"
},
{
"tags": [
"exploit"
],
"url": "https://github.com/shiky8/my--cve-vulnerability-research/blob/main/my_VulnDB_cves/CVE-TECHNOSTROBE-03-InfoDisclosure.md"
}
],
"timeline": [
{
"lang": "en",
"time": "2026-04-04T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2026-04-04T02:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2026-04-04T16:46:31.000Z",
"value": "VulDB entry last update"
}
],
"title": "Technostrobe HI-LED-WR120-G2 Configuration Data fs information disclosure"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2026-5571",
"datePublished": "2026-04-05T13:45:10.700Z",
"dateReserved": "2026-04-04T14:41:07.612Z",
"dateUpdated": "2026-04-06T15:27:09.752Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-5570 (GCVE-0-2026-5570)
Vulnerability from cvelistv5 – Published: 2026-04-05 13:30 – Updated: 2026-04-07 02:52
VLAI?
Title
Technostrobe HI-LED-WR120-G2 LoginCB index_config improper authentication
Summary
A vulnerability was determined in Technostrobe HI-LED-WR120-G2 5.5.0.1R6.03.30. The affected element is the function index_config of the file /LoginCB. This manipulation causes improper authentication. It is possible to initiate the attack remotely. The exploit has been publicly disclosed and may be utilized. The vendor was contacted early about this disclosure but did not respond in any way.
Severity ?
CWE
- CWE-287 - Improper Authentication
Assigner
References
| URL | Tags | |||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Technostrobe | HI-LED-WR120-G2 |
Affected:
5.5.0.1R6.03.30
|
Credits
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-5570",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-04-07T02:52:14.844281Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-04-07T02:52:24.106Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "HI-LED-WR120-G2",
"vendor": "Technostrobe",
"versions": [
{
"status": "affected",
"version": "5.5.0.1R6.03.30"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "shiky8 (VulDB User)"
},
{
"lang": "en",
"type": "coordinator",
"value": "VulDB CNA Team"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability was determined in Technostrobe HI-LED-WR120-G2 5.5.0.1R6.03.30. The affected element is the function index_config of the file /LoginCB. This manipulation causes improper authentication. It is possible to initiate the attack remotely. The exploit has been publicly disclosed and may be utilized. The vendor was contacted early about this disclosure but did not respond in any way."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 6.9,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N/E:P",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 7.3,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L/E:P/RL:X/RC:R",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 7.3,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L/E:P/RL:X/RC:R",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 7.5,
"vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P/E:POC/RL:ND/RC:UR",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-287",
"description": "Improper Authentication",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-04-05T13:30:13.979Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-355340 | Technostrobe HI-LED-WR120-G2 LoginCB index_config improper authentication",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/vuln/355340"
},
{
"name": "VDB-355340 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/vuln/355340/cti"
},
{
"name": "Submit #783323 | Technostrobe HI-LED-WR120-G2 Obstruction Lighting Controller 5.5.0.1R6.03.30 Authentication Bypass Issues",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/submit/783323"
},
{
"tags": [
"exploit"
],
"url": "https://github.com/shiky8/my--cve-vulnerability-research/blob/main/my_VulnDB_cves/CVE-TECHNOSTROBE-02-AuthBypass.md"
}
],
"timeline": [
{
"lang": "en",
"time": "2026-04-04T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2026-04-04T02:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2026-04-04T16:46:28.000Z",
"value": "VulDB entry last update"
}
],
"title": "Technostrobe HI-LED-WR120-G2 LoginCB index_config improper authentication"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2026-5570",
"datePublished": "2026-04-05T13:30:13.979Z",
"dateReserved": "2026-04-04T14:41:03.744Z",
"dateUpdated": "2026-04-07T02:52:24.106Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-5569 (GCVE-0-2026-5569)
Vulnerability from cvelistv5 – Published: 2026-04-05 13:15 – Updated: 2026-04-06 16:18
VLAI?
Title
Technostrobe HI-LED-WR120-G2 Endpoint access control
Summary
A vulnerability was found in Technostrobe HI-LED-WR120-G2 5.5.0.1R6.03.30. Impacted is an unknown function of the file /Technostrobe/ of the component Endpoint. The manipulation results in improper access controls. The attack may be performed from remote. The exploit has been made public and could be used. Multiple endpoints are affected. The vendor was contacted early about this disclosure but did not respond in any way.
Severity ?
Assigner
References
| URL | Tags | |||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Technostrobe | HI-LED-WR120-G2 |
Affected:
5.5.0.1R6.03.30
|
Credits
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-5569",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-04-06T16:17:54.054807Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-04-06T16:18:11.013Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"modules": [
"Endpoint"
],
"product": "HI-LED-WR120-G2",
"vendor": "Technostrobe",
"versions": [
{
"status": "affected",
"version": "5.5.0.1R6.03.30"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "shiky8 (VulDB User)"
},
{
"lang": "en",
"type": "coordinator",
"value": "VulDB CNA Team"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability was found in Technostrobe HI-LED-WR120-G2 5.5.0.1R6.03.30. Impacted is an unknown function of the file /Technostrobe/ of the component Endpoint. The manipulation results in improper access controls. The attack may be performed from remote. The exploit has been made public and could be used. Multiple endpoints are affected. The vendor was contacted early about this disclosure but did not respond in any way."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 6.9,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N/E:P",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 7.3,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L/E:P/RL:W/RC:R",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 7.3,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L/E:P/RL:W/RC:R",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 7.5,
"vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P/E:POC/RL:W/RC:UR",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-284",
"description": "Improper Access Controls",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-266",
"description": "Incorrect Privilege Assignment",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-04-05T13:15:15.167Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-355339 | Technostrobe HI-LED-WR120-G2 Endpoint access control",
"tags": [
"vdb-entry"
],
"url": "https://vuldb.com/vuln/355339"
},
{
"name": "VDB-355339 | CTI Indicators (IOB, IOC, TTP, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/vuln/355339/cti"
},
{
"name": "Submit #783322 | Technostrobe HI-LED-WR120-G2 Obstruction Lighting Controller 5.5.0.1R6.03.30 Broken Access Control",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/submit/783322"
},
{
"tags": [
"exploit"
],
"url": "https://github.com/shiky8/my--cve-vulnerability-research/blob/main/my_VulnDB_cves/CVE-TECHNOSTROBE-01-BrokenAccessControl.md"
}
],
"timeline": [
{
"lang": "en",
"time": "2026-04-04T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2026-04-04T02:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2026-04-04T16:46:24.000Z",
"value": "VulDB entry last update"
}
],
"title": "Technostrobe HI-LED-WR120-G2 Endpoint access control"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2026-5569",
"datePublished": "2026-04-05T13:15:15.167Z",
"dateReserved": "2026-04-04T14:40:50.587Z",
"dateUpdated": "2026-04-06T16:18:11.013Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}