Search criteria
1 vulnerability by Shenzhen Tenda Technology
CVE-2026-25857 (GCVE-0-2026-25857)
Vulnerability from cvelistv5 – Published: 2026-02-07 21:41 – Updated: 2026-02-10 22:17
VLAI?
Title
Tenda G300-F Command Injection via formSetWanDiag
Summary
Tenda G300-F router firmware version 16.01.14.2 and prior contain an OS command injection vulnerability in the WAN diagnostic functionality (formSetWanDiag). The implementation constructs a shell command that invokes curl and incorporates attacker-controlled input into the command line without adequate neutralization. As a result, a remote attacker with access to the affected management interface can inject additional shell syntax and execute arbitrary commands on the device with the privileges of the management process.
Severity ?
CWE
- CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
Assigner
References
| URL | Tags | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Shenzhen Tenda Technology | Tenda G300-F |
Affected:
0 , ≤ 16.01.14.2
(semver)
|
Credits
evan
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-25857",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-02-10T16:13:59.771975Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-02-10T16:14:11.633Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Tenda G300-F",
"vendor": "Shenzhen Tenda Technology",
"versions": [
{
"lessThanOrEqual": "16.01.14.2",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "evan"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Tenda G300-F router firmware version 16.01.14.2 and prior contain an OS command injection vulnerability in the WAN diagnostic functionality (formSetWanDiag). The implementation constructs a shell command that invokes curl and incorporates attacker-controlled input into the command line without adequate neutralization. As a result, a remote attacker with access to the affected management interface can inject additional shell syntax and execute arbitrary commands on the device with the privileges of the management process."
}
],
"value": "Tenda G300-F router firmware version 16.01.14.2 and prior contain an OS command injection vulnerability in the WAN diagnostic functionality (formSetWanDiag). The implementation constructs a shell command that invokes curl and incorporates attacker-controlled input into the command line without adequate neutralization. As a result, a remote attacker with access to the affected management interface can inject additional shell syntax and execute arbitrary commands on the device with the privileges of the management process."
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"baseScore": 8.6,
"baseSeverity": "HIGH",
"exploitMaturity": "NOT_DEFINED",
"privilegesRequired": "HIGH",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-78",
"description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-02-10T22:17:39.360Z",
"orgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
"shortName": "VulnCheck"
},
"references": [
{
"tags": [
"technical-description",
"exploit"
],
"url": "https://blog.evan.lat/blog/cve-2026-25857/"
},
{
"tags": [
"product"
],
"url": "https://www.tendacn.com/material/show/736333682028613"
},
{
"tags": [
"third-party-advisory"
],
"url": "https://www.vulncheck.com/advisories/tenda-g300-f-command-injection-via-formsetwandiag"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "Tenda G300-F Command Injection via formSetWanDiag",
"x_generator": {
"engine": "Vulnogram 0.5.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
"assignerShortName": "VulnCheck",
"cveId": "CVE-2026-25857",
"datePublished": "2026-02-07T21:41:41.340Z",
"dateReserved": "2026-02-06T19:12:03.462Z",
"dateUpdated": "2026-02-10T22:17:39.360Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}