Search

Find a vulnerability

Search criteria

    14 vulnerabilities by Rittal

    VAR-201910-1187

    Vulnerability from variot - Updated: 2024-11-23 23:08

    Rittal Chiller SK 3232-Series web interface as built upon Carel pCOWeb firmware A1.5.3 – B1.2.4. The authentication mechanism on affected systems does not provide a sufficient level of protection against unauthorized configuration changes. Primary operations, namely turning the cooling unit on and off and setting the temperature set point, can be modified without authentication. Carel pCOWeb Firmware is vulnerable to a lack of authentication for critical functions.Information may be tampered with. Rittal Chiller SK 3232-Series is a liquid cooling device from Rittal

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-201910-1187",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "pcoweb",
            "scope": "gte",
            "trust": 1.0,
            "vendor": "carel",
            "version": "a1.5.3"
          },
          {
            "model": "pcoweb",
            "scope": "lte",
            "trust": 1.0,
            "vendor": "carel",
            "version": "b1.2.4"
          },
          {
            "model": "pcoweb card",
            "scope": null,
            "trust": 0.8,
            "vendor": "carel industries s p a",
            "version": null
          },
          {
            "model": "chiller sk 3232-series",
            "scope": null,
            "trust": 0.6,
            "vendor": "rittal",
            "version": null
          },
          {
            "model": "pcoweb",
            "scope": "eq",
            "trust": 0.6,
            "vendor": "carel",
            "version": "b1.2.4"
          },
          {
            "model": "pcoweb",
            "scope": "eq",
            "trust": 0.6,
            "vendor": "carel",
            "version": "a1.5.3"
          },
          {
            "model": "pcoweb",
            "scope": "eq",
            "trust": 0.6,
            "vendor": "carel",
            "version": "a2.0.4"
          },
          {
            "model": "chiller sk 3232",
            "scope": "eq",
            "trust": 0.6,
            "vendor": "rittal",
            "version": null
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "pcoweb",
            "version": "*"
          }
        ],
        "sources": [
          {
            "db": "IVD",
            "id": "b9b1aba0-4836-4d8e-aa89-e14f250c31f3"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2019-38069"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2019-011385"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201910-1481"
          },
          {
            "db": "NVD",
            "id": "CVE-2019-13549"
          }
        ]
      },
      "configurations": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/configurations#",
          "children": {
            "@container": "@list"
          },
          "cpe_match": {
            "@container": "@list"
          },
          "data": {
            "@container": "@list"
          },
          "nodes": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "CVE_data_version": "4.0",
            "nodes": [
              {
                "cpe_match": [
                  {
                    "cpe22Uri": "cpe:/o:carel:pcoweb_card_firmware",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2019-011385"
          }
        ]
      },
      "cve": "CVE-2019-13549",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "nvd@nist.gov",
                "availabilityImpact": "NONE",
                "baseScore": 5.0,
                "confidentialityImpact": "NONE",
                "exploitabilityScore": 10.0,
                "id": "CVE-2019-13549",
                "impactScore": 2.9,
                "integrityImpact": "PARTIAL",
                "severity": "MEDIUM",
                "trust": 1.8,
                "vectorString": "AV:N/AC:L/Au:N/C:N/I:P/A:N",
                "version": "2.0"
              },
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "CNVD",
                "availabilityImpact": "NONE",
                "baseScore": 9.4,
                "confidentialityImpact": "COMPLETE",
                "exploitabilityScore": 10.0,
                "id": "CNVD-2019-38069",
                "impactScore": 9.2,
                "integrityImpact": "COMPLETE",
                "severity": "HIGH",
                "trust": 0.6,
                "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:N",
                "version": "2.0"
              },
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "IVD",
                "availabilityImpact": "NONE",
                "baseScore": 9.4,
                "confidentialityImpact": "COMPLETE",
                "exploitabilityScore": 10.0,
                "id": "b9b1aba0-4836-4d8e-aa89-e14f250c31f3",
                "impactScore": 9.2,
                "integrityImpact": "COMPLETE",
                "severity": "HIGH",
                "trust": 0.2,
                "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:N",
                "version": "2.9 [IVD]"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "nvd@nist.gov",
                "availabilityImpact": "NONE",
                "baseScore": 7.5,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "NONE",
                "exploitabilityScore": 3.9,
                "id": "CVE-2019-13549",
                "impactScore": 3.6,
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "trust": 1.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N",
                "version": "3.1"
              },
              {
                "attackComplexity": "Low",
                "attackVector": "Network",
                "author": "NVD",
                "availabilityImpact": "None",
                "baseScore": 7.5,
                "baseSeverity": "High",
                "confidentialityImpact": "None",
                "exploitabilityScore": null,
                "id": "CVE-2019-13549",
                "impactScore": null,
                "integrityImpact": "High",
                "privilegesRequired": "None",
                "scope": "Unchanged",
                "trust": 0.8,
                "userInteraction": "None",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "nvd@nist.gov",
                "id": "CVE-2019-13549",
                "trust": 1.0,
                "value": "HIGH"
              },
              {
                "author": "NVD",
                "id": "CVE-2019-13549",
                "trust": 0.8,
                "value": "High"
              },
              {
                "author": "CNVD",
                "id": "CNVD-2019-38069",
                "trust": 0.6,
                "value": "HIGH"
              },
              {
                "author": "CNNVD",
                "id": "CNNVD-201910-1481",
                "trust": 0.6,
                "value": "HIGH"
              },
              {
                "author": "IVD",
                "id": "b9b1aba0-4836-4d8e-aa89-e14f250c31f3",
                "trust": 0.2,
                "value": "HIGH"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "IVD",
            "id": "b9b1aba0-4836-4d8e-aa89-e14f250c31f3"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2019-38069"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2019-011385"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201910-1481"
          },
          {
            "db": "NVD",
            "id": "CVE-2019-13549"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Rittal Chiller SK 3232-Series web interface as built upon Carel pCOWeb firmware A1.5.3 \u2013 B1.2.4. The authentication mechanism on affected systems does not provide a sufficient level of protection against unauthorized configuration changes. Primary operations, namely turning the cooling unit on and off and setting the temperature set point, can be modified without authentication. Carel pCOWeb Firmware is vulnerable to a lack of authentication for critical functions.Information may be tampered with. Rittal Chiller SK 3232-Series is a liquid cooling device from Rittal",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2019-13549"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2019-011385"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2019-38069"
          },
          {
            "db": "IVD",
            "id": "b9b1aba0-4836-4d8e-aa89-e14f250c31f3"
          }
        ],
        "trust": 2.34
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2019-13549",
            "trust": 3.2
          },
          {
            "db": "ICS CERT",
            "id": "ICSA-19-297-01",
            "trust": 3.0
          },
          {
            "db": "CNVD",
            "id": "CNVD-2019-38069",
            "trust": 0.8
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201910-1481",
            "trust": 0.8
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2019-011385",
            "trust": 0.8
          },
          {
            "db": "IVD",
            "id": "B9B1ABA0-4836-4D8E-AA89-E14F250C31F3",
            "trust": 0.2
          }
        ],
        "sources": [
          {
            "db": "IVD",
            "id": "b9b1aba0-4836-4d8e-aa89-e14f250c31f3"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2019-38069"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2019-011385"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201910-1481"
          },
          {
            "db": "NVD",
            "id": "CVE-2019-13549"
          }
        ]
      },
      "id": "VAR-201910-1187",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "IVD",
            "id": "b9b1aba0-4836-4d8e-aa89-e14f250c31f3"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2019-38069"
          }
        ],
        "trust": 1.8
      },
      "iot_taxonomy": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "category": [
              "ICS",
              "Network device"
            ],
            "sub_category": null,
            "trust": 0.6
          },
          {
            "category": [
              "ICS"
            ],
            "sub_category": null,
            "trust": 0.2
          }
        ],
        "sources": [
          {
            "db": "IVD",
            "id": "b9b1aba0-4836-4d8e-aa89-e14f250c31f3"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2019-38069"
          }
        ]
      },
      "last_update_date": "2024-11-23T23:08:14.092000Z",
      "patch": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/patch#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "title": "pCOWeb card",
            "trust": 0.8,
            "url": "https://www.carel.com/bms-building-management-system-na/-/journal_content/56_INSTANCE_i4q5KIMLInKK/10191/55239"
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2019-011385"
          }
        ]
      },
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-306",
            "trust": 1.8
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2019-011385"
          },
          {
            "db": "NVD",
            "id": "CVE-2019-13549"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 3.0,
            "url": "https://www.us-cert.gov/ics/advisories/icsa-19-297-01"
          },
          {
            "trust": 1.6,
            "url": "http://seclists.org/fulldisclosure/2019/oct/46"
          },
          {
            "trust": 1.4,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2019-13549"
          },
          {
            "trust": 0.8,
            "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2019-13549"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2019-38069"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2019-011385"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201910-1481"
          },
          {
            "db": "NVD",
            "id": "CVE-2019-13549"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "IVD",
            "id": "b9b1aba0-4836-4d8e-aa89-e14f250c31f3"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2019-38069"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2019-011385"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201910-1481"
          },
          {
            "db": "NVD",
            "id": "CVE-2019-13549"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2019-10-30T00:00:00",
            "db": "IVD",
            "id": "b9b1aba0-4836-4d8e-aa89-e14f250c31f3"
          },
          {
            "date": "2019-10-30T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2019-38069"
          },
          {
            "date": "2019-11-06T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2019-011385"
          },
          {
            "date": "2019-10-24T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-201910-1481"
          },
          {
            "date": "2019-10-25T18:15:10.880000",
            "db": "NVD",
            "id": "CVE-2019-13549"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2019-10-30T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2019-38069"
          },
          {
            "date": "2019-11-06T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2019-011385"
          },
          {
            "date": "2020-02-12T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-201910-1481"
          },
          {
            "date": "2024-11-21T04:25:07.587000",
            "db": "NVD",
            "id": "CVE-2019-13549"
          }
        ]
      },
      "threat_type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "remote",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-201910-1481"
          }
        ],
        "trust": 0.6
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Rittal Chiller SK 3232-Series Improper access control vulnerability",
        "sources": [
          {
            "db": "IVD",
            "id": "b9b1aba0-4836-4d8e-aa89-e14f250c31f3"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2019-38069"
          }
        ],
        "trust": 0.8
      },
      "type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Access control error",
        "sources": [
          {
            "db": "IVD",
            "id": "b9b1aba0-4836-4d8e-aa89-e14f250c31f3"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201910-1481"
          }
        ],
        "trust": 0.8
      }
    }

    VAR-201910-1189

    Vulnerability from variot - Updated: 2024-11-23 23:08

    Rittal Chiller SK 3232-Series web interface as built upon Carel pCOWeb firmware A1.5.3 – B1.2.4. The authentication mechanism on affected systems is configured using hard-coded credentials. These credentials could allow attackers to influence the primary operations of the affected systems, namely turning the cooling unit on and off and setting the temperature set point. Carel pCOWeb The firmware contains a vulnerability related to the use of hard-coded credentials.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. Rittal Chiller SK 3232-Series is a liquid cooling device from Rittal

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-201910-1189",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "pcoweb",
            "scope": "gte",
            "trust": 1.0,
            "vendor": "carel",
            "version": "a1.5.3"
          },
          {
            "model": "pcoweb",
            "scope": "lte",
            "trust": 1.0,
            "vendor": "carel",
            "version": "b1.2.4"
          },
          {
            "model": "pcoweb card",
            "scope": null,
            "trust": 0.8,
            "vendor": "carel industries s p a",
            "version": null
          },
          {
            "model": "chiller sk 3232-series",
            "scope": null,
            "trust": 0.6,
            "vendor": "rittal",
            "version": null
          },
          {
            "model": "pcoweb",
            "scope": "eq",
            "trust": 0.6,
            "vendor": "carel",
            "version": "b1.2.4"
          },
          {
            "model": "pcoweb",
            "scope": "eq",
            "trust": 0.6,
            "vendor": "carel",
            "version": "a1.5.3"
          },
          {
            "model": "pcoweb",
            "scope": "eq",
            "trust": 0.6,
            "vendor": "carel",
            "version": "a2.0.4"
          },
          {
            "model": "chiller sk 3232",
            "scope": "eq",
            "trust": 0.6,
            "vendor": "rittal",
            "version": null
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "pcoweb",
            "version": "*"
          }
        ],
        "sources": [
          {
            "db": "IVD",
            "id": "e41e3f25-7243-4c72-8763-2ef6d713b92a"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2019-39583"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2019-011384"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201910-1480"
          },
          {
            "db": "NVD",
            "id": "CVE-2019-13553"
          }
        ]
      },
      "configurations": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/configurations#",
          "children": {
            "@container": "@list"
          },
          "cpe_match": {
            "@container": "@list"
          },
          "data": {
            "@container": "@list"
          },
          "nodes": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "CVE_data_version": "4.0",
            "nodes": [
              {
                "cpe_match": [
                  {
                    "cpe22Uri": "cpe:/o:carel:pcoweb_card_firmware",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2019-011384"
          }
        ]
      },
      "cve": "CVE-2019-13553",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "nvd@nist.gov",
                "availabilityImpact": "COMPLETE",
                "baseScore": 10.0,
                "confidentialityImpact": "COMPLETE",
                "exploitabilityScore": 10.0,
                "id": "CVE-2019-13553",
                "impactScore": 10.0,
                "integrityImpact": "COMPLETE",
                "severity": "HIGH",
                "trust": 1.8,
                "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
                "version": "2.0"
              },
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "CNVD",
                "availabilityImpact": "COMPLETE",
                "baseScore": 10.0,
                "confidentialityImpact": "COMPLETE",
                "exploitabilityScore": 10.0,
                "id": "CNVD-2019-39583",
                "impactScore": 10.0,
                "integrityImpact": "COMPLETE",
                "severity": "HIGH",
                "trust": 0.6,
                "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
                "version": "2.0"
              },
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "IVD",
                "availabilityImpact": "COMPLETE",
                "baseScore": 10.0,
                "confidentialityImpact": "COMPLETE",
                "exploitabilityScore": 10.0,
                "id": "e41e3f25-7243-4c72-8763-2ef6d713b92a",
                "impactScore": 10.0,
                "integrityImpact": "COMPLETE",
                "severity": "HIGH",
                "trust": 0.2,
                "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
                "version": "2.9 [IVD]"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "nvd@nist.gov",
                "availabilityImpact": "HIGH",
                "baseScore": 9.8,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 3.9,
                "id": "CVE-2019-13553",
                "impactScore": 5.9,
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "trust": 1.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              {
                "attackComplexity": "Low",
                "attackVector": "Network",
                "author": "NVD",
                "availabilityImpact": "High",
                "baseScore": 9.8,
                "baseSeverity": "Critical",
                "confidentialityImpact": "High",
                "exploitabilityScore": null,
                "id": "CVE-2019-13553",
                "impactScore": null,
                "integrityImpact": "High",
                "privilegesRequired": "None",
                "scope": "Unchanged",
                "trust": 0.8,
                "userInteraction": "None",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "nvd@nist.gov",
                "id": "CVE-2019-13553",
                "trust": 1.0,
                "value": "CRITICAL"
              },
              {
                "author": "NVD",
                "id": "CVE-2019-13553",
                "trust": 0.8,
                "value": "Critical"
              },
              {
                "author": "CNVD",
                "id": "CNVD-2019-39583",
                "trust": 0.6,
                "value": "HIGH"
              },
              {
                "author": "CNNVD",
                "id": "CNNVD-201910-1480",
                "trust": 0.6,
                "value": "CRITICAL"
              },
              {
                "author": "IVD",
                "id": "e41e3f25-7243-4c72-8763-2ef6d713b92a",
                "trust": 0.2,
                "value": "CRITICAL"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "IVD",
            "id": "e41e3f25-7243-4c72-8763-2ef6d713b92a"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2019-39583"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2019-011384"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201910-1480"
          },
          {
            "db": "NVD",
            "id": "CVE-2019-13553"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Rittal Chiller SK 3232-Series web interface as built upon Carel pCOWeb firmware A1.5.3 \u2013 B1.2.4. The authentication mechanism on affected systems is configured using hard-coded credentials. These credentials could allow attackers to influence the primary operations of the affected systems, namely turning the cooling unit on and off and setting the temperature set point. Carel pCOWeb The firmware contains a vulnerability related to the use of hard-coded credentials.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. Rittal Chiller SK 3232-Series is a liquid cooling device from Rittal",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2019-13553"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2019-011384"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2019-39583"
          },
          {
            "db": "IVD",
            "id": "e41e3f25-7243-4c72-8763-2ef6d713b92a"
          }
        ],
        "trust": 2.34
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2019-13553",
            "trust": 3.2
          },
          {
            "db": "ICS CERT",
            "id": "ICSA-19-297-01",
            "trust": 3.0
          },
          {
            "db": "CNVD",
            "id": "CNVD-2019-39583",
            "trust": 0.8
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201910-1480",
            "trust": 0.8
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2019-011384",
            "trust": 0.8
          },
          {
            "db": "IVD",
            "id": "E41E3F25-7243-4C72-8763-2EF6D713B92A",
            "trust": 0.2
          }
        ],
        "sources": [
          {
            "db": "IVD",
            "id": "e41e3f25-7243-4c72-8763-2ef6d713b92a"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2019-39583"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2019-011384"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201910-1480"
          },
          {
            "db": "NVD",
            "id": "CVE-2019-13553"
          }
        ]
      },
      "id": "VAR-201910-1189",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "IVD",
            "id": "e41e3f25-7243-4c72-8763-2ef6d713b92a"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2019-39583"
          }
        ],
        "trust": 1.8
      },
      "iot_taxonomy": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "category": [
              "ICS",
              "Network device"
            ],
            "sub_category": null,
            "trust": 0.6
          },
          {
            "category": [
              "ICS"
            ],
            "sub_category": null,
            "trust": 0.2
          }
        ],
        "sources": [
          {
            "db": "IVD",
            "id": "e41e3f25-7243-4c72-8763-2ef6d713b92a"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2019-39583"
          }
        ]
      },
      "last_update_date": "2024-11-23T23:08:14.062000Z",
      "patch": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/patch#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "title": "pCOWeb card",
            "trust": 0.8,
            "url": "https://www.carel.com/bms-building-management-system-na/-/journal_content/56_INSTANCE_i4q5KIMLInKK/10191/55239"
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2019-011384"
          }
        ]
      },
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-798",
            "trust": 1.8
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2019-011384"
          },
          {
            "db": "NVD",
            "id": "CVE-2019-13553"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 3.0,
            "url": "https://www.us-cert.gov/ics/advisories/icsa-19-297-01"
          },
          {
            "trust": 1.6,
            "url": "http://seclists.org/fulldisclosure/2019/oct/45"
          },
          {
            "trust": 1.4,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2019-13553"
          },
          {
            "trust": 0.8,
            "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2019-13553"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2019-39583"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2019-011384"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201910-1480"
          },
          {
            "db": "NVD",
            "id": "CVE-2019-13553"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "IVD",
            "id": "e41e3f25-7243-4c72-8763-2ef6d713b92a"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2019-39583"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2019-011384"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201910-1480"
          },
          {
            "db": "NVD",
            "id": "CVE-2019-13553"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2019-11-07T00:00:00",
            "db": "IVD",
            "id": "e41e3f25-7243-4c72-8763-2ef6d713b92a"
          },
          {
            "date": "2019-11-07T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2019-39583"
          },
          {
            "date": "2019-11-06T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2019-011384"
          },
          {
            "date": "2019-10-24T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-201910-1480"
          },
          {
            "date": "2019-10-25T18:15:10.943000",
            "db": "NVD",
            "id": "CVE-2019-13553"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2019-11-07T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2019-39583"
          },
          {
            "date": "2019-11-06T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2019-011384"
          },
          {
            "date": "2020-02-12T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-201910-1480"
          },
          {
            "date": "2024-11-21T04:25:08.087000",
            "db": "NVD",
            "id": "CVE-2019-13553"
          }
        ]
      },
      "threat_type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "remote",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-201910-1480"
          }
        ],
        "trust": 0.6
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Rittal Chiller SK 3232-Series Trust Management Issue Vulnerability",
        "sources": [
          {
            "db": "IVD",
            "id": "e41e3f25-7243-4c72-8763-2ef6d713b92a"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2019-39583"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201910-1480"
          }
        ],
        "trust": 1.4
      },
      "type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "trust management problem",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-201910-1480"
          }
        ],
        "trust": 0.6
      }
    }

    CVE-2022-40633 (GCVE-0-2022-40633)

    Vulnerability from nvd – Published: 2023-03-02 22:18 – Updated: 2025-01-17 22:11
    VLAI
    Title
    Rittal CMC III Improper Access Control
    Summary
    A malicious actor can clone access cards used to open control cabinets secured with Rittal CMC III locks.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2025-01-17 17:01 UTC
    Assigner
    icscert CNA under the icscert root
    CNA scorecard B 75/100 over 337 records in the last 180 days details
    Impacted products
    Vendor Product Version
    Rittal CMC III Affected: all versions
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T12:21:46.545Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-061-03"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "cvssV3_1": {
                  "attackComplexity": "LOW",
                  "attackVector": "PHYSICAL",
                  "availabilityImpact": "NONE",
                  "baseScore": 4.6,
                  "baseSeverity": "MEDIUM",
                  "confidentialityImpact": "HIGH",
                  "integrityImpact": "NONE",
                  "privilegesRequired": "NONE",
                  "scope": "UNCHANGED",
                  "userInteraction": "NONE",
                  "vectorString": "CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
                  "version": "3.1"
                }
              },
              {
                "other": {
                  "content": {
                    "id": "CVE-2022-40633",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-01-17T17:01:43.026101Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "problemTypes": [
              {
                "descriptions": [
                  {
                    "description": "CWE-noinfo Not enough information",
                    "lang": "en",
                    "type": "CWE"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-01-17T22:11:59.387Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "CMC III",
              "vendor": "Rittal",
              "versions": [
                {
                  "status": "affected",
                  "version": "all versions"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A malicious actor can clone access cards used to open control cabinets secured with Rittal CMC III locks."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "CWE-284",
                  "lang": "en"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2023-03-02T22:18:31.192Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-061-03"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": "Rittal CMC III Improper Access Control",
          "x_generator": {
            "engine": "VINCE 2.0.6",
            "env": "prod",
            "origin": "https://cveawg.mitre.org/api/cve/CVE-2022-40633"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2022-40633",
        "datePublished": "2023-03-02T22:18:31.192Z",
        "dateReserved": "2022-12-21T17:02:52.822Z",
        "dateUpdated": "2025-01-17T22:11:59.387Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2020-11956 (GCVE-0-2020-11956)

    Vulnerability from nvd – Published: 2020-07-14 13:05 – Updated: 2024-08-04 11:42
    VLAI
    Summary
    An issue was discovered on Rittal PDU-3C002DEC through 5.17.10 and CMCIII-PU-9333E0FB through 3.17.10 devices. There is a least privilege violation.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Assigner
    mitre CNA under the mitre root
    CNA scorecard E 29/100 over 2125 records in the last 180 days details
    References
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T11:42:00.931Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://sec-consult.com/en/blog/advisories/multiple-critical-vulnerabilities-in-multiple-rittal-products-based-on-same-software/"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "An issue was discovered on Rittal PDU-3C002DEC through 5.17.10 and CMCIII-PU-9333E0FB through 3.17.10 devices. There is a least privilege violation."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2020-07-14T13:05:39.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://sec-consult.com/en/blog/advisories/multiple-critical-vulnerabilities-in-multiple-rittal-products-based-on-same-software/"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cve@mitre.org",
              "ID": "CVE-2020-11956",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "An issue was discovered on Rittal PDU-3C002DEC through 5.17.10 and CMCIII-PU-9333E0FB through 3.17.10 devices. There is a least privilege violation."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://sec-consult.com/en/blog/advisories/multiple-critical-vulnerabilities-in-multiple-rittal-products-based-on-same-software/",
                  "refsource": "MISC",
                  "url": "https://sec-consult.com/en/blog/advisories/multiple-critical-vulnerabilities-in-multiple-rittal-products-based-on-same-software/"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2020-11956",
        "datePublished": "2020-07-14T13:05:39.000Z",
        "dateReserved": "2020-04-20T00:00:00.000Z",
        "dateUpdated": "2024-08-04T11:42:00.931Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2020-11955 (GCVE-0-2020-11955)

    Vulnerability from nvd – Published: 2020-07-14 13:03 – Updated: 2024-08-04 11:42
    VLAI
    Summary
    An issue was discovered on Rittal PDU-3C002DEC through 5.15.70 and CMCIII-PU-9333E0FB through 3.15.70 devices. There are insecure permissions.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Assigner
    mitre CNA under the mitre root
    CNA scorecard E 29/100 over 2125 records in the last 180 days details
    References
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T11:42:00.786Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://sec-consult.com/en/blog/advisories/multiple-critical-vulnerabilities-in-multiple-rittal-products-based-on-same-software/"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "An issue was discovered on Rittal PDU-3C002DEC through 5.15.70 and CMCIII-PU-9333E0FB through 3.15.70 devices. There are insecure permissions."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2020-07-14T13:03:51.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://sec-consult.com/en/blog/advisories/multiple-critical-vulnerabilities-in-multiple-rittal-products-based-on-same-software/"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cve@mitre.org",
              "ID": "CVE-2020-11955",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "An issue was discovered on Rittal PDU-3C002DEC through 5.15.70 and CMCIII-PU-9333E0FB through 3.15.70 devices. There are insecure permissions."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://sec-consult.com/en/blog/advisories/multiple-critical-vulnerabilities-in-multiple-rittal-products-based-on-same-software/",
                  "refsource": "MISC",
                  "url": "https://sec-consult.com/en/blog/advisories/multiple-critical-vulnerabilities-in-multiple-rittal-products-based-on-same-software/"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2020-11955",
        "datePublished": "2020-07-14T13:03:51.000Z",
        "dateReserved": "2020-04-20T00:00:00.000Z",
        "dateUpdated": "2024-08-04T11:42:00.786Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2020-11953 (GCVE-0-2020-11953)

    Vulnerability from nvd – Published: 2020-07-14 13:02 – Updated: 2024-08-04 11:42
    VLAI
    Summary
    An issue was discovered on Rittal PDU-3C002DEC through 5.15.40 and CMCIII-PU-9333E0FB through 3.15.70_4 devices. Attackers can execute code.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Assigner
    mitre CNA under the mitre root
    CNA scorecard E 29/100 over 2125 records in the last 180 days details
    References
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T11:42:00.820Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://sec-consult.com/en/blog/advisories/multiple-critical-vulnerabilities-in-multiple-rittal-products-based-on-same-software/"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "An issue was discovered on Rittal PDU-3C002DEC through 5.15.40 and CMCIII-PU-9333E0FB through 3.15.70_4 devices. Attackers can execute code."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2020-07-14T13:02:40.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://sec-consult.com/en/blog/advisories/multiple-critical-vulnerabilities-in-multiple-rittal-products-based-on-same-software/"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cve@mitre.org",
              "ID": "CVE-2020-11953",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "An issue was discovered on Rittal PDU-3C002DEC through 5.15.40 and CMCIII-PU-9333E0FB through 3.15.70_4 devices. Attackers can execute code."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://sec-consult.com/en/blog/advisories/multiple-critical-vulnerabilities-in-multiple-rittal-products-based-on-same-software/",
                  "refsource": "MISC",
                  "url": "https://sec-consult.com/en/blog/advisories/multiple-critical-vulnerabilities-in-multiple-rittal-products-based-on-same-software/"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2020-11953",
        "datePublished": "2020-07-14T13:02:40.000Z",
        "dateReserved": "2020-04-20T00:00:00.000Z",
        "dateUpdated": "2024-08-04T11:42:00.820Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2020-11952 (GCVE-0-2020-11952)

    Vulnerability from nvd – Published: 2020-07-14 13:01 – Updated: 2024-08-04 11:42
    VLAI
    Summary
    An issue was discovered on Rittal PDU-3C002DEC through 5.17.10 and CMCIII-PU-9333E0FB through 3.17.10 devices. Attackers can bypass the CLI menu.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Assigner
    mitre CNA under the mitre root
    CNA scorecard E 29/100 over 2125 records in the last 180 days details
    References
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T11:42:00.542Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://sec-consult.com/en/blog/advisories/multiple-critical-vulnerabilities-in-multiple-rittal-products-based-on-same-software/"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "An issue was discovered on Rittal PDU-3C002DEC through 5.17.10 and CMCIII-PU-9333E0FB through 3.17.10 devices. Attackers can bypass the CLI menu."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2020-07-14T13:01:31.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://sec-consult.com/en/blog/advisories/multiple-critical-vulnerabilities-in-multiple-rittal-products-based-on-same-software/"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cve@mitre.org",
              "ID": "CVE-2020-11952",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "An issue was discovered on Rittal PDU-3C002DEC through 5.17.10 and CMCIII-PU-9333E0FB through 3.17.10 devices. Attackers can bypass the CLI menu."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://sec-consult.com/en/blog/advisories/multiple-critical-vulnerabilities-in-multiple-rittal-products-based-on-same-software/",
                  "refsource": "MISC",
                  "url": "https://sec-consult.com/en/blog/advisories/multiple-critical-vulnerabilities-in-multiple-rittal-products-based-on-same-software/"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2020-11952",
        "datePublished": "2020-07-14T13:01:31.000Z",
        "dateReserved": "2020-04-20T00:00:00.000Z",
        "dateUpdated": "2024-08-04T11:42:00.542Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2020-11951 (GCVE-0-2020-11951)

    Vulnerability from nvd – Published: 2020-07-14 13:00 – Updated: 2024-08-04 11:42
    VLAI
    Summary
    An issue was discovered on Rittal PDU-3C002DEC through 5.17.10 and CMCIII-PU-9333E0FB through 3.17.10 devices. There is a Backdoor root account.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Assigner
    mitre CNA under the mitre root
    CNA scorecard E 29/100 over 2125 records in the last 180 days details
    References
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T11:42:00.834Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://sec-consult.com/en/blog/advisories/multiple-critical-vulnerabilities-in-multiple-rittal-products-based-on-same-software/"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "An issue was discovered on Rittal PDU-3C002DEC through 5.17.10 and CMCIII-PU-9333E0FB through 3.17.10 devices. There is a Backdoor root account."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2020-07-14T13:00:40.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://sec-consult.com/en/blog/advisories/multiple-critical-vulnerabilities-in-multiple-rittal-products-based-on-same-software/"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cve@mitre.org",
              "ID": "CVE-2020-11951",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "An issue was discovered on Rittal PDU-3C002DEC through 5.17.10 and CMCIII-PU-9333E0FB through 3.17.10 devices. There is a Backdoor root account."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://sec-consult.com/en/blog/advisories/multiple-critical-vulnerabilities-in-multiple-rittal-products-based-on-same-software/",
                  "refsource": "MISC",
                  "url": "https://sec-consult.com/en/blog/advisories/multiple-critical-vulnerabilities-in-multiple-rittal-products-based-on-same-software/"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2020-11951",
        "datePublished": "2020-07-14T13:00:40.000Z",
        "dateReserved": "2020-04-20T00:00:00.000Z",
        "dateUpdated": "2024-08-04T11:42:00.834Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2022-40633 (GCVE-0-2022-40633)

    Vulnerability from cvelistv5 – Published: 2023-03-02 22:18 – Updated: 2025-01-17 22:11
    VLAI
    Title
    Rittal CMC III Improper Access Control
    Summary
    A malicious actor can clone access cards used to open control cabinets secured with Rittal CMC III locks.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2025-01-17 17:01 UTC
    Assigner
    icscert CNA under the icscert root
    CNA scorecard B 75/100 over 337 records in the last 180 days details
    Impacted products
    Vendor Product Version
    Rittal CMC III Affected: all versions
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T12:21:46.545Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-061-03"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "cvssV3_1": {
                  "attackComplexity": "LOW",
                  "attackVector": "PHYSICAL",
                  "availabilityImpact": "NONE",
                  "baseScore": 4.6,
                  "baseSeverity": "MEDIUM",
                  "confidentialityImpact": "HIGH",
                  "integrityImpact": "NONE",
                  "privilegesRequired": "NONE",
                  "scope": "UNCHANGED",
                  "userInteraction": "NONE",
                  "vectorString": "CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
                  "version": "3.1"
                }
              },
              {
                "other": {
                  "content": {
                    "id": "CVE-2022-40633",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-01-17T17:01:43.026101Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "problemTypes": [
              {
                "descriptions": [
                  {
                    "description": "CWE-noinfo Not enough information",
                    "lang": "en",
                    "type": "CWE"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-01-17T22:11:59.387Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "CMC III",
              "vendor": "Rittal",
              "versions": [
                {
                  "status": "affected",
                  "version": "all versions"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A malicious actor can clone access cards used to open control cabinets secured with Rittal CMC III locks."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "CWE-284",
                  "lang": "en"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2023-03-02T22:18:31.192Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-061-03"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": "Rittal CMC III Improper Access Control",
          "x_generator": {
            "engine": "VINCE 2.0.6",
            "env": "prod",
            "origin": "https://cveawg.mitre.org/api/cve/CVE-2022-40633"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2022-40633",
        "datePublished": "2023-03-02T22:18:31.192Z",
        "dateReserved": "2022-12-21T17:02:52.822Z",
        "dateUpdated": "2025-01-17T22:11:59.387Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2020-11956 (GCVE-0-2020-11956)

    Vulnerability from cvelistv5 – Published: 2020-07-14 13:05 – Updated: 2024-08-04 11:42
    VLAI
    Summary
    An issue was discovered on Rittal PDU-3C002DEC through 5.17.10 and CMCIII-PU-9333E0FB through 3.17.10 devices. There is a least privilege violation.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Assigner
    mitre CNA under the mitre root
    CNA scorecard E 29/100 over 2125 records in the last 180 days details
    References
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T11:42:00.931Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://sec-consult.com/en/blog/advisories/multiple-critical-vulnerabilities-in-multiple-rittal-products-based-on-same-software/"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "An issue was discovered on Rittal PDU-3C002DEC through 5.17.10 and CMCIII-PU-9333E0FB through 3.17.10 devices. There is a least privilege violation."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2020-07-14T13:05:39.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://sec-consult.com/en/blog/advisories/multiple-critical-vulnerabilities-in-multiple-rittal-products-based-on-same-software/"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cve@mitre.org",
              "ID": "CVE-2020-11956",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "An issue was discovered on Rittal PDU-3C002DEC through 5.17.10 and CMCIII-PU-9333E0FB through 3.17.10 devices. There is a least privilege violation."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://sec-consult.com/en/blog/advisories/multiple-critical-vulnerabilities-in-multiple-rittal-products-based-on-same-software/",
                  "refsource": "MISC",
                  "url": "https://sec-consult.com/en/blog/advisories/multiple-critical-vulnerabilities-in-multiple-rittal-products-based-on-same-software/"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2020-11956",
        "datePublished": "2020-07-14T13:05:39.000Z",
        "dateReserved": "2020-04-20T00:00:00.000Z",
        "dateUpdated": "2024-08-04T11:42:00.931Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2020-11955 (GCVE-0-2020-11955)

    Vulnerability from cvelistv5 – Published: 2020-07-14 13:03 – Updated: 2024-08-04 11:42
    VLAI
    Summary
    An issue was discovered on Rittal PDU-3C002DEC through 5.15.70 and CMCIII-PU-9333E0FB through 3.15.70 devices. There are insecure permissions.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Assigner
    mitre CNA under the mitre root
    CNA scorecard E 29/100 over 2125 records in the last 180 days details
    References
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T11:42:00.786Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://sec-consult.com/en/blog/advisories/multiple-critical-vulnerabilities-in-multiple-rittal-products-based-on-same-software/"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "An issue was discovered on Rittal PDU-3C002DEC through 5.15.70 and CMCIII-PU-9333E0FB through 3.15.70 devices. There are insecure permissions."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2020-07-14T13:03:51.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://sec-consult.com/en/blog/advisories/multiple-critical-vulnerabilities-in-multiple-rittal-products-based-on-same-software/"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cve@mitre.org",
              "ID": "CVE-2020-11955",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "An issue was discovered on Rittal PDU-3C002DEC through 5.15.70 and CMCIII-PU-9333E0FB through 3.15.70 devices. There are insecure permissions."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://sec-consult.com/en/blog/advisories/multiple-critical-vulnerabilities-in-multiple-rittal-products-based-on-same-software/",
                  "refsource": "MISC",
                  "url": "https://sec-consult.com/en/blog/advisories/multiple-critical-vulnerabilities-in-multiple-rittal-products-based-on-same-software/"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2020-11955",
        "datePublished": "2020-07-14T13:03:51.000Z",
        "dateReserved": "2020-04-20T00:00:00.000Z",
        "dateUpdated": "2024-08-04T11:42:00.786Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2020-11953 (GCVE-0-2020-11953)

    Vulnerability from cvelistv5 – Published: 2020-07-14 13:02 – Updated: 2024-08-04 11:42
    VLAI
    Summary
    An issue was discovered on Rittal PDU-3C002DEC through 5.15.40 and CMCIII-PU-9333E0FB through 3.15.70_4 devices. Attackers can execute code.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Assigner
    mitre CNA under the mitre root
    CNA scorecard E 29/100 over 2125 records in the last 180 days details
    References
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T11:42:00.820Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://sec-consult.com/en/blog/advisories/multiple-critical-vulnerabilities-in-multiple-rittal-products-based-on-same-software/"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "An issue was discovered on Rittal PDU-3C002DEC through 5.15.40 and CMCIII-PU-9333E0FB through 3.15.70_4 devices. Attackers can execute code."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2020-07-14T13:02:40.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://sec-consult.com/en/blog/advisories/multiple-critical-vulnerabilities-in-multiple-rittal-products-based-on-same-software/"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cve@mitre.org",
              "ID": "CVE-2020-11953",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "An issue was discovered on Rittal PDU-3C002DEC through 5.15.40 and CMCIII-PU-9333E0FB through 3.15.70_4 devices. Attackers can execute code."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://sec-consult.com/en/blog/advisories/multiple-critical-vulnerabilities-in-multiple-rittal-products-based-on-same-software/",
                  "refsource": "MISC",
                  "url": "https://sec-consult.com/en/blog/advisories/multiple-critical-vulnerabilities-in-multiple-rittal-products-based-on-same-software/"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2020-11953",
        "datePublished": "2020-07-14T13:02:40.000Z",
        "dateReserved": "2020-04-20T00:00:00.000Z",
        "dateUpdated": "2024-08-04T11:42:00.820Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2020-11952 (GCVE-0-2020-11952)

    Vulnerability from cvelistv5 – Published: 2020-07-14 13:01 – Updated: 2024-08-04 11:42
    VLAI
    Summary
    An issue was discovered on Rittal PDU-3C002DEC through 5.17.10 and CMCIII-PU-9333E0FB through 3.17.10 devices. Attackers can bypass the CLI menu.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Assigner
    mitre CNA under the mitre root
    CNA scorecard E 29/100 over 2125 records in the last 180 days details
    References
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T11:42:00.542Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://sec-consult.com/en/blog/advisories/multiple-critical-vulnerabilities-in-multiple-rittal-products-based-on-same-software/"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "An issue was discovered on Rittal PDU-3C002DEC through 5.17.10 and CMCIII-PU-9333E0FB through 3.17.10 devices. Attackers can bypass the CLI menu."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2020-07-14T13:01:31.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://sec-consult.com/en/blog/advisories/multiple-critical-vulnerabilities-in-multiple-rittal-products-based-on-same-software/"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cve@mitre.org",
              "ID": "CVE-2020-11952",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "An issue was discovered on Rittal PDU-3C002DEC through 5.17.10 and CMCIII-PU-9333E0FB through 3.17.10 devices. Attackers can bypass the CLI menu."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://sec-consult.com/en/blog/advisories/multiple-critical-vulnerabilities-in-multiple-rittal-products-based-on-same-software/",
                  "refsource": "MISC",
                  "url": "https://sec-consult.com/en/blog/advisories/multiple-critical-vulnerabilities-in-multiple-rittal-products-based-on-same-software/"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2020-11952",
        "datePublished": "2020-07-14T13:01:31.000Z",
        "dateReserved": "2020-04-20T00:00:00.000Z",
        "dateUpdated": "2024-08-04T11:42:00.542Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2020-11951 (GCVE-0-2020-11951)

    Vulnerability from cvelistv5 – Published: 2020-07-14 13:00 – Updated: 2024-08-04 11:42
    VLAI
    Summary
    An issue was discovered on Rittal PDU-3C002DEC through 5.17.10 and CMCIII-PU-9333E0FB through 3.17.10 devices. There is a Backdoor root account.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Assigner
    mitre CNA under the mitre root
    CNA scorecard E 29/100 over 2125 records in the last 180 days details
    References
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T11:42:00.834Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://sec-consult.com/en/blog/advisories/multiple-critical-vulnerabilities-in-multiple-rittal-products-based-on-same-software/"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "An issue was discovered on Rittal PDU-3C002DEC through 5.17.10 and CMCIII-PU-9333E0FB through 3.17.10 devices. There is a Backdoor root account."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2020-07-14T13:00:40.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://sec-consult.com/en/blog/advisories/multiple-critical-vulnerabilities-in-multiple-rittal-products-based-on-same-software/"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cve@mitre.org",
              "ID": "CVE-2020-11951",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "An issue was discovered on Rittal PDU-3C002DEC through 5.17.10 and CMCIII-PU-9333E0FB through 3.17.10 devices. There is a Backdoor root account."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://sec-consult.com/en/blog/advisories/multiple-critical-vulnerabilities-in-multiple-rittal-products-based-on-same-software/",
                  "refsource": "MISC",
                  "url": "https://sec-consult.com/en/blog/advisories/multiple-critical-vulnerabilities-in-multiple-rittal-products-based-on-same-software/"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2020-11951",
        "datePublished": "2020-07-14T13:00:40.000Z",
        "dateReserved": "2020-04-20T00:00:00.000Z",
        "dateUpdated": "2024-08-04T11:42:00.834Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }