Search

Find a vulnerability

Search criteria

    4 vulnerabilities by Murrelektronik

    CVE-2026-8173 (GCVE-0-2026-8173)

    Vulnerability from nvd – Published: 2026-08-24 06:47 – Updated: 2026-08-27 16:46
    VLAI
    Title
    Information Disclosure via 'Copy learned MAC Addresses' Function
    Summary
    The web GUI of affected Murrelektronik Xelity switches logs MAC addresses from the devices MAC address table when an authenticated administrator uses the 'Copy learned MAC Addresses' function. Due to improper generation of error messages, an unauthenticated attacker with network access to the web interface can retrieve the logged MAC addresses via browser developer tools.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: partial
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-08-27 16:11 UTC
    CWE
    • CWE-209 - Generation of Error Message Containing Sensitive Information
    References
    Impacted products
    Vendor Product Version
    Murrelektronik Xelity 4TX M GE Affected: 2.1.0
    Create a notification for this product.
    Murrelektronik Xelity 4TX M GE PN Affected: 2.1.0
    Create a notification for this product.
    Murrelektronik Xelity 6TX M GE Affected: 2.1.0
    Create a notification for this product.
    Murrelektronik Xelity 6TX M GE PN Affected: 2.1.0
    Create a notification for this product.
    Murrelektronik Xelity 8TX M GE Affected: 2.1.0
    Create a notification for this product.
    Murrelektronik Xelity 8TX M GE PN Affected: 2.1.0
    Create a notification for this product.
    Murrelektronik Xelity-16TX-M-GE Affected: 2.1.0
    Create a notification for this product.
    Murrelektronik Xelity-16TX-M-GE-PN Affected: 2.1.0
    Create a notification for this product.
    Murrelektronik Xelity 10 TX IP67 M FE 4P Affected: 2.1.0
    Create a notification for this product.
    Murrelektronik Xelity 10 TX IP67 M FE PN 4P Affected: 2.1.0
    Create a notification for this product.
    Murrelektronik Xelity 8 +2 TX IP67 M GE 4P Affected: 2.1.0
    Create a notification for this product.
    Murrelektronik Xelity 8 +2 TX IP67 M GE PN 4P Affected: 2.1.0
    Create a notification for this product.
    Murrelektronik Xelity 10 TX IP67 M GE 4P Affected: 2.1.0
    Create a notification for this product.
    Murrelektronik Xelity 10 TX IP67 M GE PN 4P Affected: 2.1.0
    Create a notification for this product.
    Murrelektronik Xelity 6TX 4PW IP67 M GE PN 4P Affected: 2.1.0
    Create a notification for this product.
    Murrelektronik Xelity 10 TX IP67 M FE 5P Affected: 2.1.0
    Create a notification for this product.
    Murrelektronik Xelity 10 TX IP67 M FE PN 5P Affected: 2.1.0
    Create a notification for this product.
    Murrelektronik Xelity 8 +2 TX IP67 M GE 5P Affected: 2.1.0
    Create a notification for this product.
    Murrelektronik Xelity 8 +2 TX IP67 M GE PN 5P Affected: 2.1.0
    Create a notification for this product.
    Murrelektronik Xelity 10 TX IP67 M GE 5P Affected: 2.1.0
    Create a notification for this product.
    Murrelektronik Xelity 10 TX IP67 M GE PN 5P Affected: 2.1.0
    Create a notification for this product.
    Murrelektronik Xelity 6TX 4PW IP67 M GE PN 5P Affected: 2.1.0
    Create a notification for this product.
    Murrelektronik 6 TX M GE + 4 Power M12 IP67 Affected: 2.1.0
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-8173",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-08-27T16:11:35.747277Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-08-27T16:46:11.517Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "Xelity 4TX M GE",
              "vendor": "Murrelektronik",
              "versions": [
                {
                  "status": "affected",
                  "version": "2.1.0"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Xelity 4TX M GE PN",
              "vendor": "Murrelektronik",
              "versions": [
                {
                  "status": "affected",
                  "version": "2.1.0"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Xelity 6TX M GE",
              "vendor": "Murrelektronik",
              "versions": [
                {
                  "status": "affected",
                  "version": "2.1.0"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Xelity 6TX M GE PN",
              "vendor": "Murrelektronik",
              "versions": [
                {
                  "status": "affected",
                  "version": "2.1.0"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Xelity 8TX M GE",
              "vendor": "Murrelektronik",
              "versions": [
                {
                  "status": "affected",
                  "version": "2.1.0"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Xelity 8TX M GE PN",
              "vendor": "Murrelektronik",
              "versions": [
                {
                  "status": "affected",
                  "version": "2.1.0"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Xelity-16TX-M-GE",
              "vendor": "Murrelektronik",
              "versions": [
                {
                  "status": "affected",
                  "version": "2.1.0"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Xelity-16TX-M-GE-PN",
              "vendor": "Murrelektronik",
              "versions": [
                {
                  "status": "affected",
                  "version": "2.1.0"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Xelity 10 TX IP67 M FE 4P",
              "vendor": "Murrelektronik",
              "versions": [
                {
                  "status": "affected",
                  "version": "2.1.0"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Xelity 10 TX IP67 M FE PN 4P",
              "vendor": "Murrelektronik",
              "versions": [
                {
                  "status": "affected",
                  "version": "2.1.0"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Xelity 8 +2 TX IP67 M GE 4P",
              "vendor": "Murrelektronik",
              "versions": [
                {
                  "status": "affected",
                  "version": "2.1.0"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Xelity 8 +2 TX IP67 M GE PN 4P",
              "vendor": "Murrelektronik",
              "versions": [
                {
                  "status": "affected",
                  "version": "2.1.0"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Xelity 10 TX IP67 M GE 4P",
              "vendor": "Murrelektronik",
              "versions": [
                {
                  "status": "affected",
                  "version": "2.1.0"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Xelity 10 TX IP67 M GE PN 4P",
              "vendor": "Murrelektronik",
              "versions": [
                {
                  "status": "affected",
                  "version": "2.1.0"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Xelity 6TX 4PW IP67 M GE PN 4P",
              "vendor": "Murrelektronik",
              "versions": [
                {
                  "status": "affected",
                  "version": "2.1.0"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Xelity 10 TX IP67 M FE 5P",
              "vendor": "Murrelektronik",
              "versions": [
                {
                  "status": "affected",
                  "version": "2.1.0"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Xelity 10 TX IP67 M FE PN 5P",
              "vendor": "Murrelektronik",
              "versions": [
                {
                  "status": "affected",
                  "version": "2.1.0"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Xelity 8 +2 TX IP67 M GE 5P",
              "vendor": "Murrelektronik",
              "versions": [
                {
                  "status": "affected",
                  "version": "2.1.0"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Xelity 8 +2 TX IP67 M GE PN 5P",
              "vendor": "Murrelektronik",
              "versions": [
                {
                  "status": "affected",
                  "version": "2.1.0"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Xelity 10 TX IP67 M GE 5P",
              "vendor": "Murrelektronik",
              "versions": [
                {
                  "status": "affected",
                  "version": "2.1.0"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Xelity 10 TX IP67 M GE PN 5P",
              "vendor": "Murrelektronik",
              "versions": [
                {
                  "status": "affected",
                  "version": "2.1.0"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Xelity 6TX 4PW IP67 M GE PN 5P",
              "vendor": "Murrelektronik",
              "versions": [
                {
                  "status": "affected",
                  "version": "2.1.0"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "6 TX M GE + 4 Power M12 IP67",
              "vendor": "Murrelektronik",
              "versions": [
                {
                  "status": "affected",
                  "version": "2.1.0"
                }
              ]
            }
          ],
          "cpeApplicability": [
            {
              "nodes": [
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:o:murrelektronik:xelity_firmware:V2.1.0:*:*:*:*:*:58820:*",
                      "versionStartIncluding": "2.1.0",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                }
              ],
              "operator": "OR"
            },
            {
              "nodes": [
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:o:murrelektronik:xelity_firmware:V2.1.0:*:*:*:*:*:58821:*",
                      "versionStartIncluding": "2.1.0",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                }
              ],
              "operator": "OR"
            },
            {
              "nodes": [
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:o:murrelektronik:xelity_firmware:V2.1.0:*:*:*:*:*:58822:*",
                      "versionStartIncluding": "2.1.0",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                }
              ],
              "operator": "OR"
            },
            {
              "nodes": [
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:o:murrelektronik:xelity_firmware:V2.1.0:*:*:*:*:*:58823:*",
                      "versionStartIncluding": "2.1.0",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                }
              ],
              "operator": "OR"
            },
            {
              "nodes": [
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:o:murrelektronik:xelity_firmware:V2.1.0:*:*:*:*:*:58824:*",
                      "versionStartIncluding": "2.1.0",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                }
              ],
              "operator": "OR"
            },
            {
              "nodes": [
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:o:murrelektronik:xelity_firmware:V2.1.0:*:*:*:*:*:58825:*",
                      "versionStartIncluding": "2.1.0",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                }
              ],
              "operator": "OR"
            },
            {
              "nodes": [
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:o:murrelektronik:xelity_firmware:V2.1.0:*:*:*:*:*:58826:*",
                      "versionStartIncluding": "2.1.0",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                }
              ],
              "operator": "OR"
            },
            {
              "nodes": [
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:o:murrelektronik:xelity_firmware:V2.1.0:*:*:*:*:*:58827:*",
                      "versionStartIncluding": "2.1.0",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                }
              ],
              "operator": "OR"
            },
            {
              "nodes": [
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:o:murrelektronik:xelity_firmware:V2.1.0:*:*:*:*:*:58840:*",
                      "versionStartIncluding": "2.1.0",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                }
              ],
              "operator": "OR"
            },
            {
              "nodes": [
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:o:murrelektronik:xelity_firmware:V2.1.0:*:*:*:*:*:58841:*",
                      "versionStartIncluding": "2.1.0",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                }
              ],
              "operator": "OR"
            },
            {
              "nodes": [
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:o:murrelektronik:xelity_firmware:V2.1.0:*:*:*:*:*:58842:*",
                      "versionStartIncluding": "2.1.0",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                }
              ],
              "operator": "OR"
            },
            {
              "nodes": [
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:o:murrelektronik:xelity_firmware:V2.1.0:*:*:*:*:*:58843:*",
                      "versionStartIncluding": "2.1.0",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                }
              ],
              "operator": "OR"
            },
            {
              "nodes": [
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:o:murrelektronik:xelity_firmware:V2.1.0:*:*:*:*:*:58844:*",
                      "versionStartIncluding": "2.1.0",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                }
              ],
              "operator": "OR"
            },
            {
              "nodes": [
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:o:murrelektronik:xelity_firmware:V2.1.0:*:*:*:*:*:58845:*",
                      "versionStartIncluding": "2.1.0",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                }
              ],
              "operator": "OR"
            },
            {
              "nodes": [
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:o:murrelektronik:xelity_firmware:V2.1.0:*:*:*:*:*:58847:*",
                      "versionStartIncluding": "2.1.0",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                }
              ],
              "operator": "OR"
            },
            {
              "nodes": [
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:o:murrelektronik:xelity_firmware:V2.1.0:*:*:*:*:*:58850:*",
                      "versionStartIncluding": "2.1.0",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                }
              ],
              "operator": "OR"
            },
            {
              "nodes": [
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:o:murrelektronik:xelity_firmware:V2.1.0:*:*:*:*:*:58851:*",
                      "versionStartIncluding": "2.1.0",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                }
              ],
              "operator": "OR"
            },
            {
              "nodes": [
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:o:murrelektronik:xelity_firmware:V2.1.0:*:*:*:*:*:58852:*",
                      "versionStartIncluding": "2.1.0",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                }
              ],
              "operator": "OR"
            },
            {
              "nodes": [
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:o:murrelektronik:xelity_firmware:V2.1.0:*:*:*:*:*:58853:*",
                      "versionStartIncluding": "2.1.0",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                }
              ],
              "operator": "OR"
            },
            {
              "nodes": [
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:o:murrelektronik:xelity_firmware:V2.1.0:*:*:*:*:*:58854:*",
                      "versionStartIncluding": "2.1.0",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                }
              ],
              "operator": "OR"
            },
            {
              "nodes": [
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:o:murrelektronik:xelity_firmware:V2.1.0:*:*:*:*:*:58855:*",
                      "versionStartIncluding": "2.1.0",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                }
              ],
              "operator": "OR"
            },
            {
              "nodes": [
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:o:murrelektronik:xelity_firmware:V2.1.0:*:*:*:*:*:58857:*",
                      "versionStartIncluding": "2.1.0",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                }
              ],
              "operator": "OR"
            },
            {
              "nodes": [
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:o:murrelektronik:xelity_firmware:V2.1.0:*:*:*:*:*:58860:*",
                      "versionStartIncluding": "2.1.0",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                }
              ],
              "operator": "OR"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cp\u003eThe web GUI of affected Murrelektronik Xelity switches logs MAC addresses from the devices MAC address table when an authenticated administrator uses the \u0027Copy learned MAC Addresses\u0027 function. Due to improper generation of error messages, an unauthenticated attacker with network access to the web interface can retrieve the logged MAC addresses via browser developer tools.\u003c/p\u003e"
                }
              ],
              "value": "The web GUI of affected Murrelektronik Xelity switches logs MAC addresses from the devices MAC address table when an authenticated administrator uses the \u0027Copy learned MAC Addresses\u0027 function. Due to improper generation of error messages, an unauthenticated attacker with network access to the web interface can retrieve the logged MAC addresses via browser developer tools."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "NETWORK",
                "baseScore": 5.3,
                "baseSeverity": "MEDIUM",
                "privilegesRequired": "NONE",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "PASSIVE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:P/VC:L/VI:N/VA:N/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "NONE",
                "vulnConfidentialityImpact": "LOW",
                "vulnIntegrityImpact": "NONE",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            },
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "NONE",
                "baseScore": 5.3,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "LOW",
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-209",
                  "description": "CWE-209 Generation of Error Message Containing Sensitive Information",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-08-24T06:47:58.406Z",
            "orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
            "shortName": "CERTVDE"
          },
          "references": [
            {
              "url": "https://www.certvde.com/en/advisories/VDE-2026-061/"
            }
          ],
          "source": {
            "advisory": "VDE-2026-061",
            "defect": [
              "CERT@VDE#642078"
            ],
            "discovery": "UNKNOWN"
          },
          "title": "Information Disclosure via \u0027Copy learned MAC Addresses\u0027 Function",
          "x_generator": {
            "engine": "Vulnogram 0.4.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
        "assignerShortName": "CERTVDE",
        "cveId": "CVE-2026-8173",
        "datePublished": "2026-08-24T06:47:58.406Z",
        "dateReserved": "2026-05-08T13:56:01.059Z",
        "dateUpdated": "2026-08-27T16:46:11.517Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2025-41718 (GCVE-0-2025-41718)

    Vulnerability from nvd – Published: 2025-10-14 08:25 – Updated: 2025-10-14 18:42
    VLAI
    Title
    Murrelektronik: Unprotected Transport of Credentials
    Summary
    A cleartext transmission of sensitive information vulnerability in the affected products allows an unauthorized remote attacker to gain login credentials and access the Web-UI.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2025-10-14 18:42 UTC
    CWE
    • CWE-319 - Cleartext Transmission of Sensitive Information
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-41718",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-10-14T18:42:07.442943Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-10-14T18:42:14.852Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "Firmware Impact67 Pro 54630",
              "vendor": "Murrelektronik",
              "versions": [
                {
                  "lessThanOrEqual": "1.08.01",
                  "status": "affected",
                  "version": "0.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Firmware Impact67 Pro 54620",
              "vendor": "Murrelektronik",
              "versions": [
                {
                  "lessThanOrEqual": "1.08.01",
                  "status": "affected",
                  "version": "0.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Firmware Impact67 Pro 54631",
              "vendor": "Murrelektronik",
              "versions": [
                {
                  "lessThanOrEqual": "1.08.05",
                  "status": "affected",
                  "version": "0.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Firmware Impact67 Pro 54632",
              "vendor": "Murrelektronik",
              "versions": [
                {
                  "lessThanOrEqual": "1.08.01",
                  "status": "affected",
                  "version": "0.0.0",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "user": "00000000-0000-4000-9000-000000000000",
              "value": "Abhishek Pandey from Payatu Security Consulting Pvt. Ltd."
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "A cleartext transmission of sensitive information vulnerability in the affected products allows an unauthorized remote attacker to gain login credentials and access the Web-UI."
                }
              ],
              "value": "A cleartext transmission of sensitive information vulnerability in the affected products allows an unauthorized remote attacker to gain login credentials and access the Web-UI."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "NONE",
                "baseScore": 7.5,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-319",
                  "description": "CWE-319 Cleartext Transmission of Sensitive Information",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-10-14T08:25:52.136Z",
            "orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
            "shortName": "CERTVDE"
          },
          "references": [
            {
              "url": "https://murrelektronik.csaf-tp.certvde.com/.well-known/csaf/white/2025/vde-2025-091.json"
            }
          ],
          "source": {
            "advisory": "VDE-2025-091",
            "defect": [
              "CERT@VDE#641864"
            ],
            "discovery": "UNKNOWN"
          },
          "title": "Murrelektronik: Unprotected Transport of Credentials",
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
        "assignerShortName": "CERTVDE",
        "cveId": "CVE-2025-41718",
        "datePublished": "2025-10-14T08:25:52.136Z",
        "dateReserved": "2025-04-16T11:17:48.313Z",
        "dateUpdated": "2025-10-14T18:42:14.852Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2026-8173 (GCVE-0-2026-8173)

    Vulnerability from cvelistv5 – Published: 2026-08-24 06:47 – Updated: 2026-08-27 16:46
    VLAI
    Title
    Information Disclosure via 'Copy learned MAC Addresses' Function
    Summary
    The web GUI of affected Murrelektronik Xelity switches logs MAC addresses from the devices MAC address table when an authenticated administrator uses the 'Copy learned MAC Addresses' function. Due to improper generation of error messages, an unauthenticated attacker with network access to the web interface can retrieve the logged MAC addresses via browser developer tools.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: partial
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-08-27 16:11 UTC
    CWE
    • CWE-209 - Generation of Error Message Containing Sensitive Information
    References
    Impacted products
    Vendor Product Version
    Murrelektronik Xelity 4TX M GE Affected: 2.1.0
    Create a notification for this product.
    Murrelektronik Xelity 4TX M GE PN Affected: 2.1.0
    Create a notification for this product.
    Murrelektronik Xelity 6TX M GE Affected: 2.1.0
    Create a notification for this product.
    Murrelektronik Xelity 6TX M GE PN Affected: 2.1.0
    Create a notification for this product.
    Murrelektronik Xelity 8TX M GE Affected: 2.1.0
    Create a notification for this product.
    Murrelektronik Xelity 8TX M GE PN Affected: 2.1.0
    Create a notification for this product.
    Murrelektronik Xelity-16TX-M-GE Affected: 2.1.0
    Create a notification for this product.
    Murrelektronik Xelity-16TX-M-GE-PN Affected: 2.1.0
    Create a notification for this product.
    Murrelektronik Xelity 10 TX IP67 M FE 4P Affected: 2.1.0
    Create a notification for this product.
    Murrelektronik Xelity 10 TX IP67 M FE PN 4P Affected: 2.1.0
    Create a notification for this product.
    Murrelektronik Xelity 8 +2 TX IP67 M GE 4P Affected: 2.1.0
    Create a notification for this product.
    Murrelektronik Xelity 8 +2 TX IP67 M GE PN 4P Affected: 2.1.0
    Create a notification for this product.
    Murrelektronik Xelity 10 TX IP67 M GE 4P Affected: 2.1.0
    Create a notification for this product.
    Murrelektronik Xelity 10 TX IP67 M GE PN 4P Affected: 2.1.0
    Create a notification for this product.
    Murrelektronik Xelity 6TX 4PW IP67 M GE PN 4P Affected: 2.1.0
    Create a notification for this product.
    Murrelektronik Xelity 10 TX IP67 M FE 5P Affected: 2.1.0
    Create a notification for this product.
    Murrelektronik Xelity 10 TX IP67 M FE PN 5P Affected: 2.1.0
    Create a notification for this product.
    Murrelektronik Xelity 8 +2 TX IP67 M GE 5P Affected: 2.1.0
    Create a notification for this product.
    Murrelektronik Xelity 8 +2 TX IP67 M GE PN 5P Affected: 2.1.0
    Create a notification for this product.
    Murrelektronik Xelity 10 TX IP67 M GE 5P Affected: 2.1.0
    Create a notification for this product.
    Murrelektronik Xelity 10 TX IP67 M GE PN 5P Affected: 2.1.0
    Create a notification for this product.
    Murrelektronik Xelity 6TX 4PW IP67 M GE PN 5P Affected: 2.1.0
    Create a notification for this product.
    Murrelektronik 6 TX M GE + 4 Power M12 IP67 Affected: 2.1.0
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-8173",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-08-27T16:11:35.747277Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-08-27T16:46:11.517Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "Xelity 4TX M GE",
              "vendor": "Murrelektronik",
              "versions": [
                {
                  "status": "affected",
                  "version": "2.1.0"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Xelity 4TX M GE PN",
              "vendor": "Murrelektronik",
              "versions": [
                {
                  "status": "affected",
                  "version": "2.1.0"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Xelity 6TX M GE",
              "vendor": "Murrelektronik",
              "versions": [
                {
                  "status": "affected",
                  "version": "2.1.0"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Xelity 6TX M GE PN",
              "vendor": "Murrelektronik",
              "versions": [
                {
                  "status": "affected",
                  "version": "2.1.0"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Xelity 8TX M GE",
              "vendor": "Murrelektronik",
              "versions": [
                {
                  "status": "affected",
                  "version": "2.1.0"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Xelity 8TX M GE PN",
              "vendor": "Murrelektronik",
              "versions": [
                {
                  "status": "affected",
                  "version": "2.1.0"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Xelity-16TX-M-GE",
              "vendor": "Murrelektronik",
              "versions": [
                {
                  "status": "affected",
                  "version": "2.1.0"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Xelity-16TX-M-GE-PN",
              "vendor": "Murrelektronik",
              "versions": [
                {
                  "status": "affected",
                  "version": "2.1.0"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Xelity 10 TX IP67 M FE 4P",
              "vendor": "Murrelektronik",
              "versions": [
                {
                  "status": "affected",
                  "version": "2.1.0"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Xelity 10 TX IP67 M FE PN 4P",
              "vendor": "Murrelektronik",
              "versions": [
                {
                  "status": "affected",
                  "version": "2.1.0"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Xelity 8 +2 TX IP67 M GE 4P",
              "vendor": "Murrelektronik",
              "versions": [
                {
                  "status": "affected",
                  "version": "2.1.0"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Xelity 8 +2 TX IP67 M GE PN 4P",
              "vendor": "Murrelektronik",
              "versions": [
                {
                  "status": "affected",
                  "version": "2.1.0"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Xelity 10 TX IP67 M GE 4P",
              "vendor": "Murrelektronik",
              "versions": [
                {
                  "status": "affected",
                  "version": "2.1.0"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Xelity 10 TX IP67 M GE PN 4P",
              "vendor": "Murrelektronik",
              "versions": [
                {
                  "status": "affected",
                  "version": "2.1.0"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Xelity 6TX 4PW IP67 M GE PN 4P",
              "vendor": "Murrelektronik",
              "versions": [
                {
                  "status": "affected",
                  "version": "2.1.0"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Xelity 10 TX IP67 M FE 5P",
              "vendor": "Murrelektronik",
              "versions": [
                {
                  "status": "affected",
                  "version": "2.1.0"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Xelity 10 TX IP67 M FE PN 5P",
              "vendor": "Murrelektronik",
              "versions": [
                {
                  "status": "affected",
                  "version": "2.1.0"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Xelity 8 +2 TX IP67 M GE 5P",
              "vendor": "Murrelektronik",
              "versions": [
                {
                  "status": "affected",
                  "version": "2.1.0"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Xelity 8 +2 TX IP67 M GE PN 5P",
              "vendor": "Murrelektronik",
              "versions": [
                {
                  "status": "affected",
                  "version": "2.1.0"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Xelity 10 TX IP67 M GE 5P",
              "vendor": "Murrelektronik",
              "versions": [
                {
                  "status": "affected",
                  "version": "2.1.0"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Xelity 10 TX IP67 M GE PN 5P",
              "vendor": "Murrelektronik",
              "versions": [
                {
                  "status": "affected",
                  "version": "2.1.0"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Xelity 6TX 4PW IP67 M GE PN 5P",
              "vendor": "Murrelektronik",
              "versions": [
                {
                  "status": "affected",
                  "version": "2.1.0"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "6 TX M GE + 4 Power M12 IP67",
              "vendor": "Murrelektronik",
              "versions": [
                {
                  "status": "affected",
                  "version": "2.1.0"
                }
              ]
            }
          ],
          "cpeApplicability": [
            {
              "nodes": [
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:o:murrelektronik:xelity_firmware:V2.1.0:*:*:*:*:*:58820:*",
                      "versionStartIncluding": "2.1.0",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                }
              ],
              "operator": "OR"
            },
            {
              "nodes": [
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:o:murrelektronik:xelity_firmware:V2.1.0:*:*:*:*:*:58821:*",
                      "versionStartIncluding": "2.1.0",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                }
              ],
              "operator": "OR"
            },
            {
              "nodes": [
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:o:murrelektronik:xelity_firmware:V2.1.0:*:*:*:*:*:58822:*",
                      "versionStartIncluding": "2.1.0",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                }
              ],
              "operator": "OR"
            },
            {
              "nodes": [
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:o:murrelektronik:xelity_firmware:V2.1.0:*:*:*:*:*:58823:*",
                      "versionStartIncluding": "2.1.0",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                }
              ],
              "operator": "OR"
            },
            {
              "nodes": [
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:o:murrelektronik:xelity_firmware:V2.1.0:*:*:*:*:*:58824:*",
                      "versionStartIncluding": "2.1.0",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                }
              ],
              "operator": "OR"
            },
            {
              "nodes": [
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:o:murrelektronik:xelity_firmware:V2.1.0:*:*:*:*:*:58825:*",
                      "versionStartIncluding": "2.1.0",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                }
              ],
              "operator": "OR"
            },
            {
              "nodes": [
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:o:murrelektronik:xelity_firmware:V2.1.0:*:*:*:*:*:58826:*",
                      "versionStartIncluding": "2.1.0",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                }
              ],
              "operator": "OR"
            },
            {
              "nodes": [
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:o:murrelektronik:xelity_firmware:V2.1.0:*:*:*:*:*:58827:*",
                      "versionStartIncluding": "2.1.0",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                }
              ],
              "operator": "OR"
            },
            {
              "nodes": [
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:o:murrelektronik:xelity_firmware:V2.1.0:*:*:*:*:*:58840:*",
                      "versionStartIncluding": "2.1.0",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                }
              ],
              "operator": "OR"
            },
            {
              "nodes": [
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:o:murrelektronik:xelity_firmware:V2.1.0:*:*:*:*:*:58841:*",
                      "versionStartIncluding": "2.1.0",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                }
              ],
              "operator": "OR"
            },
            {
              "nodes": [
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:o:murrelektronik:xelity_firmware:V2.1.0:*:*:*:*:*:58842:*",
                      "versionStartIncluding": "2.1.0",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                }
              ],
              "operator": "OR"
            },
            {
              "nodes": [
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:o:murrelektronik:xelity_firmware:V2.1.0:*:*:*:*:*:58843:*",
                      "versionStartIncluding": "2.1.0",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                }
              ],
              "operator": "OR"
            },
            {
              "nodes": [
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:o:murrelektronik:xelity_firmware:V2.1.0:*:*:*:*:*:58844:*",
                      "versionStartIncluding": "2.1.0",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                }
              ],
              "operator": "OR"
            },
            {
              "nodes": [
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:o:murrelektronik:xelity_firmware:V2.1.0:*:*:*:*:*:58845:*",
                      "versionStartIncluding": "2.1.0",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                }
              ],
              "operator": "OR"
            },
            {
              "nodes": [
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:o:murrelektronik:xelity_firmware:V2.1.0:*:*:*:*:*:58847:*",
                      "versionStartIncluding": "2.1.0",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                }
              ],
              "operator": "OR"
            },
            {
              "nodes": [
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:o:murrelektronik:xelity_firmware:V2.1.0:*:*:*:*:*:58850:*",
                      "versionStartIncluding": "2.1.0",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                }
              ],
              "operator": "OR"
            },
            {
              "nodes": [
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:o:murrelektronik:xelity_firmware:V2.1.0:*:*:*:*:*:58851:*",
                      "versionStartIncluding": "2.1.0",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                }
              ],
              "operator": "OR"
            },
            {
              "nodes": [
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:o:murrelektronik:xelity_firmware:V2.1.0:*:*:*:*:*:58852:*",
                      "versionStartIncluding": "2.1.0",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                }
              ],
              "operator": "OR"
            },
            {
              "nodes": [
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:o:murrelektronik:xelity_firmware:V2.1.0:*:*:*:*:*:58853:*",
                      "versionStartIncluding": "2.1.0",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                }
              ],
              "operator": "OR"
            },
            {
              "nodes": [
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:o:murrelektronik:xelity_firmware:V2.1.0:*:*:*:*:*:58854:*",
                      "versionStartIncluding": "2.1.0",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                }
              ],
              "operator": "OR"
            },
            {
              "nodes": [
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:o:murrelektronik:xelity_firmware:V2.1.0:*:*:*:*:*:58855:*",
                      "versionStartIncluding": "2.1.0",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                }
              ],
              "operator": "OR"
            },
            {
              "nodes": [
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:o:murrelektronik:xelity_firmware:V2.1.0:*:*:*:*:*:58857:*",
                      "versionStartIncluding": "2.1.0",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                }
              ],
              "operator": "OR"
            },
            {
              "nodes": [
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:o:murrelektronik:xelity_firmware:V2.1.0:*:*:*:*:*:58860:*",
                      "versionStartIncluding": "2.1.0",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                }
              ],
              "operator": "OR"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cp\u003eThe web GUI of affected Murrelektronik Xelity switches logs MAC addresses from the devices MAC address table when an authenticated administrator uses the \u0027Copy learned MAC Addresses\u0027 function. Due to improper generation of error messages, an unauthenticated attacker with network access to the web interface can retrieve the logged MAC addresses via browser developer tools.\u003c/p\u003e"
                }
              ],
              "value": "The web GUI of affected Murrelektronik Xelity switches logs MAC addresses from the devices MAC address table when an authenticated administrator uses the \u0027Copy learned MAC Addresses\u0027 function. Due to improper generation of error messages, an unauthenticated attacker with network access to the web interface can retrieve the logged MAC addresses via browser developer tools."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "NETWORK",
                "baseScore": 5.3,
                "baseSeverity": "MEDIUM",
                "privilegesRequired": "NONE",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "PASSIVE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:P/VC:L/VI:N/VA:N/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "NONE",
                "vulnConfidentialityImpact": "LOW",
                "vulnIntegrityImpact": "NONE",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            },
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "NONE",
                "baseScore": 5.3,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "LOW",
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-209",
                  "description": "CWE-209 Generation of Error Message Containing Sensitive Information",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-08-24T06:47:58.406Z",
            "orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
            "shortName": "CERTVDE"
          },
          "references": [
            {
              "url": "https://www.certvde.com/en/advisories/VDE-2026-061/"
            }
          ],
          "source": {
            "advisory": "VDE-2026-061",
            "defect": [
              "CERT@VDE#642078"
            ],
            "discovery": "UNKNOWN"
          },
          "title": "Information Disclosure via \u0027Copy learned MAC Addresses\u0027 Function",
          "x_generator": {
            "engine": "Vulnogram 0.4.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
        "assignerShortName": "CERTVDE",
        "cveId": "CVE-2026-8173",
        "datePublished": "2026-08-24T06:47:58.406Z",
        "dateReserved": "2026-05-08T13:56:01.059Z",
        "dateUpdated": "2026-08-27T16:46:11.517Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2025-41718 (GCVE-0-2025-41718)

    Vulnerability from cvelistv5 – Published: 2025-10-14 08:25 – Updated: 2025-10-14 18:42
    VLAI
    Title
    Murrelektronik: Unprotected Transport of Credentials
    Summary
    A cleartext transmission of sensitive information vulnerability in the affected products allows an unauthorized remote attacker to gain login credentials and access the Web-UI.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2025-10-14 18:42 UTC
    CWE
    • CWE-319 - Cleartext Transmission of Sensitive Information
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-41718",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-10-14T18:42:07.442943Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-10-14T18:42:14.852Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "Firmware Impact67 Pro 54630",
              "vendor": "Murrelektronik",
              "versions": [
                {
                  "lessThanOrEqual": "1.08.01",
                  "status": "affected",
                  "version": "0.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Firmware Impact67 Pro 54620",
              "vendor": "Murrelektronik",
              "versions": [
                {
                  "lessThanOrEqual": "1.08.01",
                  "status": "affected",
                  "version": "0.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Firmware Impact67 Pro 54631",
              "vendor": "Murrelektronik",
              "versions": [
                {
                  "lessThanOrEqual": "1.08.05",
                  "status": "affected",
                  "version": "0.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Firmware Impact67 Pro 54632",
              "vendor": "Murrelektronik",
              "versions": [
                {
                  "lessThanOrEqual": "1.08.01",
                  "status": "affected",
                  "version": "0.0.0",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "user": "00000000-0000-4000-9000-000000000000",
              "value": "Abhishek Pandey from Payatu Security Consulting Pvt. Ltd."
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "A cleartext transmission of sensitive information vulnerability in the affected products allows an unauthorized remote attacker to gain login credentials and access the Web-UI."
                }
              ],
              "value": "A cleartext transmission of sensitive information vulnerability in the affected products allows an unauthorized remote attacker to gain login credentials and access the Web-UI."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "NONE",
                "baseScore": 7.5,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-319",
                  "description": "CWE-319 Cleartext Transmission of Sensitive Information",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-10-14T08:25:52.136Z",
            "orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
            "shortName": "CERTVDE"
          },
          "references": [
            {
              "url": "https://murrelektronik.csaf-tp.certvde.com/.well-known/csaf/white/2025/vde-2025-091.json"
            }
          ],
          "source": {
            "advisory": "VDE-2025-091",
            "defect": [
              "CERT@VDE#641864"
            ],
            "discovery": "UNKNOWN"
          },
          "title": "Murrelektronik: Unprotected Transport of Credentials",
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
        "assignerShortName": "CERTVDE",
        "cveId": "CVE-2025-41718",
        "datePublished": "2025-10-14T08:25:52.136Z",
        "dateReserved": "2025-04-16T11:17:48.313Z",
        "dateUpdated": "2025-10-14T18:42:14.852Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }