Search
Find a vulnerability
Search criteria
5 vulnerabilities by FURUNO ELECTRIC CO., LTD.
JVNDB-2026-030097
Vulnerability from jvndb - Published: 2026-08-26 07:04 - Updated:2026-08-26 07:04
Severity
Summary
FURUNO ELECTRIC FA-50 CLASS B AIS TRANSPONDER uses hard-coded credentials and misses authentication for additional configuration
Details
FA-50 CLASS B AIS TRANSPONDER provided by FURUNO ELECTRIC CO., LTD. contains the following vulnerabilities.
- Use of hard-coded credentials (CWE-798) - CVE-2026-59769
- The CVSS evaluation above assumes that an attacker who knows the credentials and has access to the network to which the device is connected to operates, using that credentials, the settings screen and alter the identification number etc.
- Missing authentication for critical function (CWE-306) - CVE-2026-67578
References
| Type | URL | |||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||||||||||
Impacted products
| Vendor | Product | |
|---|---|---|
{
"@rdf:about": "https://jvndb.jvn.jp/en/contents/2026/JVNDB-2026-030097.html",
"dc:date": "2026-08-26T16:04+09:00",
"dcterms:issued": "2026-08-26T16:04+09:00",
"dcterms:modified": "2026-08-26T16:04+09:00",
"description": "FA-50 CLASS B AIS TRANSPONDER provided by FURUNO ELECTRIC CO., LTD. contains the following vulnerabilities.\u003ca href=\u0027https://cwe.mitre.org/data/definitions/798.html\u0027 target=\u0027_blank\u0027\u003e\u003c/a\u003e\u003ca href=\u0027https://cwe.mitre.org/data/definitions/306.html\u0027 target=\u0027_blank\u0027\u003e\u003c/a\u003e\u003cul\u003e\u003cli\u003eUse of hard-coded credentials (CWE-798) - CVE-2026-59769\u003c/li\u003e\u003cul\u003e\u003cli\u003eThe CVSS evaluation above assumes that an attacker who knows the credentials and has access to the network to which the device is connected to operates, using that credentials, the settings screen and alter the identification number etc.\u003c/li\u003e\u003c/ul\u003e\u003cli\u003eMissing authentication for critical function (CWE-306) - CVE-2026-67578\u003c/li\u003e\u003c/ul\u003eSouvik Kandar reported these issues to CISA ICS. At the request of the developer and CISA ICS, JPCERT/CC coordinated with the developer.",
"link": "https://jvndb.jvn.jp/en/contents/2026/JVNDB-2026-030097.html",
"sec:cpe": {
"#text": "cpe:/h:misc:furuno_fa-50",
"@product": "FA-50",
"@vendor": "FURUNO ELECTRIC CO., LTD.",
"@version": "2.2"
},
"sec:cvss": {
"@score": "9.1",
"@severity": "Critical",
"@type": "Base",
"@vector": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:H",
"@version": "3.0"
},
"sec:identifier": "JVNDB-2026-030097",
"sec:references": [
{
"#text": "https://jvn.jp/en/vu/JVNVU95422936/index.html",
"@id": "JVNVU#95422936",
"@source": "JVN"
},
{
"#text": "https://www.cve.org/CVERecord?id=CVE-2026-59769",
"@id": "CVE-2026-59769",
"@source": "CVE"
},
{
"#text": "https://www.cve.org/CVERecord?id=CVE-2026-67578",
"@id": "CVE-2026-67578",
"@source": "CVE"
},
{
"#text": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-237-07",
"@id": "ICSA-26-237-07",
"@source": "ICS-CERT ADVISORY"
},
{
"#text": "https://cwe.mitre.org/data/definitions/306.html",
"@id": "CWE-306",
"@title": "Missing Authentication for Critical Function(CWE-306)"
},
{
"#text": "https://cwe.mitre.org/data/definitions/798.html",
"@id": "CWE-798",
"@title": "Use of Hard-coded Credentials(CWE-798)"
}
],
"title": "FURUNO ELECTRIC FA-50 CLASS B AIS TRANSPONDER uses hard-coded credentials and misses authentication for additional configuration"
}
CVE-2026-67578 (GCVE-0-2026-67578)
Vulnerability from nvd – Published: 2026-08-25 07:42 – Updated: 2026-08-25 14:51
VLAI
EPSS
VEX
Summary
FA-50 all versions miss authentication for some configuration.
An attacker with access to the vessel's internal network can manipulate the product's settings screen to alter some configuration parameters.
Severity
SSVC
Exploitation: none
Automatable: yes
Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-08-25 14:44 UTC
CWE
- CWE-306 - Missing authentication for critical function
Assigner
References
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| FURUNO ELECTRIC CO., LTD. | FA-50 |
Affected:
all
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-67578",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-08-25T14:44:18.944195Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-08-25T14:51:55.561Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "FA-50",
"vendor": "FURUNO ELECTRIC CO., LTD.",
"versions": [
{
"status": "affected",
"version": "all"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "FA-50 all versions miss authentication for some configuration.\r\nAn attacker with access to the vessel\u0027s internal network can manipulate the product\u0027s settings screen to alter some configuration parameters."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 7.5,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en-US",
"value": "GENERAL"
}
]
},
{
"cvssV4_0": {
"baseScore": 8.7,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:H/VA:N/SC:N/SI:N/SA:N",
"version": "4.0"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en-US",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-306",
"description": "Missing authentication for critical function",
"lang": "en-US",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-08-25T07:42:26.438Z",
"orgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
"shortName": "jpcert"
},
"references": [
{
"url": "https://www.furuno.co.jp/en/news/notice/notice_category.html?itemid=1857\u0026dispmid=965"
},
{
"url": "https://www.furuno.co.jp/news/notice/notice_category.html?itemid=1856\u0026dispmid=1039"
},
{
"url": "https://jvn.jp/en/vu/JVNVU95422936/"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
"assignerShortName": "jpcert",
"cveId": "CVE-2026-67578",
"datePublished": "2026-08-25T07:42:26.438Z",
"dateReserved": "2026-08-04T01:31:35.564Z",
"dateUpdated": "2026-08-25T14:51:55.561Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-59769 (GCVE-0-2026-59769)
Vulnerability from nvd – Published: 2026-08-25 07:43 – Updated: 2026-08-25 14:51
VLAI
EPSS
VEX
Summary
FA-50 all versions contain hard-coded credentials.
An attacker, who knows the credentials and has access to the vessel's internal network, can operate the settings screen using that credentials to alter the identification number.
Severity
9.1 (Critical)
SSVC
Exploitation: none
Automatable: yes
Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-08-25 14:43 UTC
CWE
- CWE-798 - Use of hard-coded credentials
Assigner
References
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| FURUNO ELECTRIC CO., LTD. | FA-50 |
Affected:
all
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-59769",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-08-25T14:43:59.820594Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-08-25T14:51:55.400Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "FA-50",
"vendor": "FURUNO ELECTRIC CO., LTD.",
"versions": [
{
"status": "affected",
"version": "all"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "FA-50 all versions contain hard-coded credentials.\r\nAn attacker, who knows the credentials and has access to the vessel\u0027s internal network, can operate the settings screen using that credentials to alter the identification number."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 9.1,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en-US",
"value": "GENERAL"
}
]
},
{
"cvssV4_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en-US",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-798",
"description": "Use of hard-coded credentials",
"lang": "en-US",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-08-25T07:43:10.005Z",
"orgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
"shortName": "jpcert"
},
"references": [
{
"url": "https://www.furuno.co.jp/en/news/notice/notice_category.html?itemid=1857\u0026dispmid=965"
},
{
"url": "https://www.furuno.co.jp/news/notice/notice_category.html?itemid=1856\u0026dispmid=1039"
},
{
"url": "https://jvn.jp/en/vu/JVNVU95422936/"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
"assignerShortName": "jpcert",
"cveId": "CVE-2026-59769",
"datePublished": "2026-08-25T07:43:10.005Z",
"dateReserved": "2026-08-04T01:31:34.626Z",
"dateUpdated": "2026-08-25T14:51:55.400Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-59769 (GCVE-0-2026-59769)
Vulnerability from cvelistv5 – Published: 2026-08-25 07:43 – Updated: 2026-08-25 14:51
VLAI
EPSS
VEX
Summary
FA-50 all versions contain hard-coded credentials.
An attacker, who knows the credentials and has access to the vessel's internal network, can operate the settings screen using that credentials to alter the identification number.
Severity
9.1 (Critical)
SSVC
Exploitation: none
Automatable: yes
Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-08-25 14:43 UTC
CWE
- CWE-798 - Use of hard-coded credentials
Assigner
References
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| FURUNO ELECTRIC CO., LTD. | FA-50 |
Affected:
all
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-59769",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-08-25T14:43:59.820594Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-08-25T14:51:55.400Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "FA-50",
"vendor": "FURUNO ELECTRIC CO., LTD.",
"versions": [
{
"status": "affected",
"version": "all"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "FA-50 all versions contain hard-coded credentials.\r\nAn attacker, who knows the credentials and has access to the vessel\u0027s internal network, can operate the settings screen using that credentials to alter the identification number."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 9.1,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en-US",
"value": "GENERAL"
}
]
},
{
"cvssV4_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en-US",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-798",
"description": "Use of hard-coded credentials",
"lang": "en-US",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-08-25T07:43:10.005Z",
"orgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
"shortName": "jpcert"
},
"references": [
{
"url": "https://www.furuno.co.jp/en/news/notice/notice_category.html?itemid=1857\u0026dispmid=965"
},
{
"url": "https://www.furuno.co.jp/news/notice/notice_category.html?itemid=1856\u0026dispmid=1039"
},
{
"url": "https://jvn.jp/en/vu/JVNVU95422936/"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
"assignerShortName": "jpcert",
"cveId": "CVE-2026-59769",
"datePublished": "2026-08-25T07:43:10.005Z",
"dateReserved": "2026-08-04T01:31:34.626Z",
"dateUpdated": "2026-08-25T14:51:55.400Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-67578 (GCVE-0-2026-67578)
Vulnerability from cvelistv5 – Published: 2026-08-25 07:42 – Updated: 2026-08-25 14:51
VLAI
EPSS
VEX
Summary
FA-50 all versions miss authentication for some configuration.
An attacker with access to the vessel's internal network can manipulate the product's settings screen to alter some configuration parameters.
Severity
SSVC
Exploitation: none
Automatable: yes
Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-08-25 14:44 UTC
CWE
- CWE-306 - Missing authentication for critical function
Assigner
References
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| FURUNO ELECTRIC CO., LTD. | FA-50 |
Affected:
all
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-67578",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-08-25T14:44:18.944195Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-08-25T14:51:55.561Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "FA-50",
"vendor": "FURUNO ELECTRIC CO., LTD.",
"versions": [
{
"status": "affected",
"version": "all"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "FA-50 all versions miss authentication for some configuration.\r\nAn attacker with access to the vessel\u0027s internal network can manipulate the product\u0027s settings screen to alter some configuration parameters."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 7.5,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en-US",
"value": "GENERAL"
}
]
},
{
"cvssV4_0": {
"baseScore": 8.7,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:H/VA:N/SC:N/SI:N/SA:N",
"version": "4.0"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en-US",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-306",
"description": "Missing authentication for critical function",
"lang": "en-US",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-08-25T07:42:26.438Z",
"orgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
"shortName": "jpcert"
},
"references": [
{
"url": "https://www.furuno.co.jp/en/news/notice/notice_category.html?itemid=1857\u0026dispmid=965"
},
{
"url": "https://www.furuno.co.jp/news/notice/notice_category.html?itemid=1856\u0026dispmid=1039"
},
{
"url": "https://jvn.jp/en/vu/JVNVU95422936/"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
"assignerShortName": "jpcert",
"cveId": "CVE-2026-67578",
"datePublished": "2026-08-25T07:42:26.438Z",
"dateReserved": "2026-08-04T01:31:35.564Z",
"dateUpdated": "2026-08-25T14:51:55.561Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}