Search

Find a vulnerability

Search criteria

    57 vulnerabilities by Azure

    CVE-2026-42316 (GCVE-0-2026-42316)

    Vulnerability from nvd – Published: 2026-05-11 16:41 – Updated: 2026-05-11 17:27
    VLAI
    Title
    KQL injection via kusto.tables.topics.mapping in kafka-sink-azure-kusto
    Summary
    kafka-sink-azure-kusto Kafka Connect plugin is the official Microsoft sink for Azure Data Explorer (Kusto). Prior to 5.2.3, kafka-sink-azure-kusto did not sanitize user-controlled values inside the kusto.tables.topics.mapping configuration. The db, table, mapping, and format fields of each mapping entry were interpolated directly into KQL management/query commands via String.formatted(...) (e.g., FETCH_TABLE_COMMAND.formatted(table) → "<table> | count", FETCH_TABLE_MAPPING_COMMAND.formatted(table, format, mapping) → ".show table <table> ingestion <format> mapping '<mapping>'"). An actor able to influence the connector configuration (for example, someone with permissions to submit or edit Kafka Connect connector configs) could embed KQL metacharacters (;, |, ') to execute arbitrary management commands in the context of the connector's service principal — enabling schema enumeration/modification, ingestion-mapping tampering, or changes to streaming/retention policies on the target Azure Data Explorer database. This is a tampering vulnerability. Exploitation requires privileged access to the connector configuration; no end-user interaction or Kafka record payload is involved. This vulnerability is fixed in 5.2.3.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-943 - Improper Neutralization of Special Elements in Data Query Logic
    Assigner
    Impacted products
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-42316",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-05-11T17:27:18.333065Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-05-11T17:27:23.704Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "kafka-sink-azure-kusto",
              "vendor": "Azure",
              "versions": [
                {
                  "status": "affected",
                  "version": "\u003c 5.2.3"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "kafka-sink-azure-kusto Kafka Connect plugin is the official Microsoft sink for Azure Data Explorer (Kusto). Prior to 5.2.3, kafka-sink-azure-kusto did not sanitize user-controlled values inside the kusto.tables.topics.mapping configuration. The db, table, mapping, and format fields of each mapping entry were interpolated directly into KQL management/query commands via String.formatted(...) (e.g., FETCH_TABLE_COMMAND.formatted(table) \u2192 \"\u003ctable\u003e | count\", FETCH_TABLE_MAPPING_COMMAND.formatted(table, format, mapping) \u2192 \".show table \u003ctable\u003e ingestion \u003cformat\u003e mapping \u0027\u003cmapping\u003e\u0027\"). An actor able to influence the connector configuration (for example, someone with permissions to submit or edit Kafka Connect connector configs) could embed KQL metacharacters (;, |, \u0027) to execute arbitrary management commands in the context of the connector\u0027s service principal \u2014 enabling schema enumeration/modification, ingestion-mapping tampering, or changes to streaming/retention policies on the target Azure Data Explorer database. This is a tampering vulnerability. Exploitation requires privileged access to the connector configuration; no end-user interaction or Kafka record payload is involved. This vulnerability is fixed in 5.2.3."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "NONE",
                "baseScore": 5.9,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "HIGH",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:N/E:P/RL:O/RC:C",
                "version": "3.1"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-943",
                  "description": "CWE-943: Improper Neutralization of Special Elements in Data Query Logic",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-05-11T16:41:07.091Z",
            "orgId": "a0819718-46f1-4df5-94e2-005712e83aaa",
            "shortName": "GitHub_M"
          },
          "references": [
            {
              "name": "https://github.com/Azure/kafka-sink-azure-kusto/security/advisories/GHSA-c9mr-mqvh-6wgj",
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://github.com/Azure/kafka-sink-azure-kusto/security/advisories/GHSA-c9mr-mqvh-6wgj"
            },
            {
              "name": "https://github.com/Azure/kafka-sink-azure-kusto/pull/155",
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://github.com/Azure/kafka-sink-azure-kusto/pull/155"
            },
            {
              "name": "https://github.com/Azure/kafka-sink-azure-kusto/releases/tag/v5.2.3",
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://github.com/Azure/kafka-sink-azure-kusto/releases/tag/v5.2.3"
            }
          ],
          "source": {
            "advisory": "GHSA-c9mr-mqvh-6wgj",
            "discovery": "UNKNOWN"
          },
          "title": "KQL injection via kusto.tables.topics.mapping in kafka-sink-azure-kusto"
        }
      },
      "cveMetadata": {
        "assignerOrgId": "a0819718-46f1-4df5-94e2-005712e83aaa",
        "assignerShortName": "GitHub_M",
        "cveId": "CVE-2026-42316",
        "datePublished": "2026-05-11T16:41:07.091Z",
        "dateReserved": "2026-04-26T12:37:18.170Z",
        "dateUpdated": "2026-05-11T17:27:23.704Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-32952 (GCVE-0-2026-32952)

    Vulnerability from nvd – Published: 2026-04-24 01:46 – Updated: 2026-04-24 16:29
    VLAI
    Title
    go-ntlmssp NTLM challenges can panic on malformed payloads
    Summary
    go-ntlmssp is a Go package that provides NTLM/Negotiate authentication over HTTP. Prior to version 0.1.1, a malicious NTLM challenge message can causes an slice out of bounds panic, which can crash any Go process using `ntlmssp.Negotiator` as an HTTP transport. Version 0.1.1 patches the issue.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-190 - Integer Overflow or Wraparound
    Assigner
    References
    Impacted products
    Vendor Product Version
    Azure go-ntlmssp Affected: < 0.1.1
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-32952",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-04-24T16:29:17.449582Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-04-24T16:29:28.264Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "go-ntlmssp",
              "vendor": "Azure",
              "versions": [
                {
                  "status": "affected",
                  "version": "\u003c 0.1.1"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "go-ntlmssp is a Go package that provides NTLM/Negotiate authentication over HTTP. Prior to version 0.1.1, a malicious NTLM challenge message can causes an slice out of bounds panic, which can crash any Go process using `ntlmssp.Negotiator` as an HTTP transport. Version 0.1.1 patches the issue."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "LOW",
                "baseScore": 5.3,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "NONE",
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L",
                "version": "3.1"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-190",
                  "description": "CWE-190: Integer Overflow or Wraparound",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-04-24T01:46:31.573Z",
            "orgId": "a0819718-46f1-4df5-94e2-005712e83aaa",
            "shortName": "GitHub_M"
          },
          "references": [
            {
              "name": "https://github.com/Azure/go-ntlmssp/security/advisories/GHSA-pjcq-xvwq-hhpj",
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://github.com/Azure/go-ntlmssp/security/advisories/GHSA-pjcq-xvwq-hhpj"
            },
            {
              "name": "https://github.com/Azure/go-ntlmssp/releases/tag/v0.1.1",
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://github.com/Azure/go-ntlmssp/releases/tag/v0.1.1"
            }
          ],
          "source": {
            "advisory": "GHSA-pjcq-xvwq-hhpj",
            "discovery": "UNKNOWN"
          },
          "title": "go-ntlmssp NTLM challenges can panic on malformed payloads"
        }
      },
      "cveMetadata": {
        "assignerOrgId": "a0819718-46f1-4df5-94e2-005712e83aaa",
        "assignerShortName": "GitHub_M",
        "cveId": "CVE-2026-32952",
        "datePublished": "2026-04-24T01:46:31.573Z",
        "dateReserved": "2026-03-17T00:05:53.285Z",
        "dateUpdated": "2026-04-24T16:29:28.264Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-42316 (GCVE-0-2026-42316)

    Vulnerability from cvelistv5 – Published: 2026-05-11 16:41 – Updated: 2026-05-11 17:27
    VLAI
    Title
    KQL injection via kusto.tables.topics.mapping in kafka-sink-azure-kusto
    Summary
    kafka-sink-azure-kusto Kafka Connect plugin is the official Microsoft sink for Azure Data Explorer (Kusto). Prior to 5.2.3, kafka-sink-azure-kusto did not sanitize user-controlled values inside the kusto.tables.topics.mapping configuration. The db, table, mapping, and format fields of each mapping entry were interpolated directly into KQL management/query commands via String.formatted(...) (e.g., FETCH_TABLE_COMMAND.formatted(table) → "<table> | count", FETCH_TABLE_MAPPING_COMMAND.formatted(table, format, mapping) → ".show table <table> ingestion <format> mapping '<mapping>'"). An actor able to influence the connector configuration (for example, someone with permissions to submit or edit Kafka Connect connector configs) could embed KQL metacharacters (;, |, ') to execute arbitrary management commands in the context of the connector's service principal — enabling schema enumeration/modification, ingestion-mapping tampering, or changes to streaming/retention policies on the target Azure Data Explorer database. This is a tampering vulnerability. Exploitation requires privileged access to the connector configuration; no end-user interaction or Kafka record payload is involved. This vulnerability is fixed in 5.2.3.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-943 - Improper Neutralization of Special Elements in Data Query Logic
    Assigner
    Impacted products
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-42316",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-05-11T17:27:18.333065Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-05-11T17:27:23.704Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "kafka-sink-azure-kusto",
              "vendor": "Azure",
              "versions": [
                {
                  "status": "affected",
                  "version": "\u003c 5.2.3"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "kafka-sink-azure-kusto Kafka Connect plugin is the official Microsoft sink for Azure Data Explorer (Kusto). Prior to 5.2.3, kafka-sink-azure-kusto did not sanitize user-controlled values inside the kusto.tables.topics.mapping configuration. The db, table, mapping, and format fields of each mapping entry were interpolated directly into KQL management/query commands via String.formatted(...) (e.g., FETCH_TABLE_COMMAND.formatted(table) \u2192 \"\u003ctable\u003e | count\", FETCH_TABLE_MAPPING_COMMAND.formatted(table, format, mapping) \u2192 \".show table \u003ctable\u003e ingestion \u003cformat\u003e mapping \u0027\u003cmapping\u003e\u0027\"). An actor able to influence the connector configuration (for example, someone with permissions to submit or edit Kafka Connect connector configs) could embed KQL metacharacters (;, |, \u0027) to execute arbitrary management commands in the context of the connector\u0027s service principal \u2014 enabling schema enumeration/modification, ingestion-mapping tampering, or changes to streaming/retention policies on the target Azure Data Explorer database. This is a tampering vulnerability. Exploitation requires privileged access to the connector configuration; no end-user interaction or Kafka record payload is involved. This vulnerability is fixed in 5.2.3."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "NONE",
                "baseScore": 5.9,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "HIGH",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:N/E:P/RL:O/RC:C",
                "version": "3.1"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-943",
                  "description": "CWE-943: Improper Neutralization of Special Elements in Data Query Logic",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-05-11T16:41:07.091Z",
            "orgId": "a0819718-46f1-4df5-94e2-005712e83aaa",
            "shortName": "GitHub_M"
          },
          "references": [
            {
              "name": "https://github.com/Azure/kafka-sink-azure-kusto/security/advisories/GHSA-c9mr-mqvh-6wgj",
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://github.com/Azure/kafka-sink-azure-kusto/security/advisories/GHSA-c9mr-mqvh-6wgj"
            },
            {
              "name": "https://github.com/Azure/kafka-sink-azure-kusto/pull/155",
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://github.com/Azure/kafka-sink-azure-kusto/pull/155"
            },
            {
              "name": "https://github.com/Azure/kafka-sink-azure-kusto/releases/tag/v5.2.3",
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://github.com/Azure/kafka-sink-azure-kusto/releases/tag/v5.2.3"
            }
          ],
          "source": {
            "advisory": "GHSA-c9mr-mqvh-6wgj",
            "discovery": "UNKNOWN"
          },
          "title": "KQL injection via kusto.tables.topics.mapping in kafka-sink-azure-kusto"
        }
      },
      "cveMetadata": {
        "assignerOrgId": "a0819718-46f1-4df5-94e2-005712e83aaa",
        "assignerShortName": "GitHub_M",
        "cveId": "CVE-2026-42316",
        "datePublished": "2026-05-11T16:41:07.091Z",
        "dateReserved": "2026-04-26T12:37:18.170Z",
        "dateUpdated": "2026-05-11T17:27:23.704Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-32952 (GCVE-0-2026-32952)

    Vulnerability from cvelistv5 – Published: 2026-04-24 01:46 – Updated: 2026-04-24 16:29
    VLAI
    Title
    go-ntlmssp NTLM challenges can panic on malformed payloads
    Summary
    go-ntlmssp is a Go package that provides NTLM/Negotiate authentication over HTTP. Prior to version 0.1.1, a malicious NTLM challenge message can causes an slice out of bounds panic, which can crash any Go process using `ntlmssp.Negotiator` as an HTTP transport. Version 0.1.1 patches the issue.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-190 - Integer Overflow or Wraparound
    Assigner
    References
    Impacted products
    Vendor Product Version
    Azure go-ntlmssp Affected: < 0.1.1
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-32952",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-04-24T16:29:17.449582Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-04-24T16:29:28.264Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "go-ntlmssp",
              "vendor": "Azure",
              "versions": [
                {
                  "status": "affected",
                  "version": "\u003c 0.1.1"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "go-ntlmssp is a Go package that provides NTLM/Negotiate authentication over HTTP. Prior to version 0.1.1, a malicious NTLM challenge message can causes an slice out of bounds panic, which can crash any Go process using `ntlmssp.Negotiator` as an HTTP transport. Version 0.1.1 patches the issue."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "LOW",
                "baseScore": 5.3,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "NONE",
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L",
                "version": "3.1"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-190",
                  "description": "CWE-190: Integer Overflow or Wraparound",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-04-24T01:46:31.573Z",
            "orgId": "a0819718-46f1-4df5-94e2-005712e83aaa",
            "shortName": "GitHub_M"
          },
          "references": [
            {
              "name": "https://github.com/Azure/go-ntlmssp/security/advisories/GHSA-pjcq-xvwq-hhpj",
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://github.com/Azure/go-ntlmssp/security/advisories/GHSA-pjcq-xvwq-hhpj"
            },
            {
              "name": "https://github.com/Azure/go-ntlmssp/releases/tag/v0.1.1",
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://github.com/Azure/go-ntlmssp/releases/tag/v0.1.1"
            }
          ],
          "source": {
            "advisory": "GHSA-pjcq-xvwq-hhpj",
            "discovery": "UNKNOWN"
          },
          "title": "go-ntlmssp NTLM challenges can panic on malformed payloads"
        }
      },
      "cveMetadata": {
        "assignerOrgId": "a0819718-46f1-4df5-94e2-005712e83aaa",
        "assignerShortName": "GitHub_M",
        "cveId": "CVE-2026-32952",
        "datePublished": "2026-04-24T01:46:31.573Z",
        "dateReserved": "2026-03-17T00:05:53.285Z",
        "dateUpdated": "2026-04-24T16:29:28.264Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    VAR-202510-4377

    Vulnerability from variot - Updated: 2025-11-28 04:21

    Enabled serial console could potentially leak information that might help attacker to find vulnerabilities.This issue affects BLU-IC2: through 1.19.5; BLU-IC4: through 1.19.5. Azure Access Technology BLU-IC2 and Azure Access Technology BLU-IC4 are both network access controllers from Azure Access Technology, Inc., a US-based company.

    Both Azure Access Technology BLU-IC2 and Azure Access Technology BLU-IC4 contain an information disclosure vulnerability caused by a flaw in the serial console. Attackers could exploit this vulnerability to obtain sensitive information

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-202510-4377",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "blu-ic2",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "azure access",
            "version": "1.20"
          },
          {
            "model": "blu-ic4",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "azure access",
            "version": "1.20"
          },
          {
            "model": "access technology blu-ic2",
            "scope": "lte",
            "trust": 0.6,
            "vendor": "azure",
            "version": "\u003c=1.19.5"
          },
          {
            "model": "access technology blu-ic4",
            "scope": "lte",
            "trust": 0.6,
            "vendor": "azure",
            "version": "\u003c=1.19.5"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-29086"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-12114"
          }
        ]
      },
      "cve": "CVE-2025-12114",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "accessComplexity": "LOW",
                "accessVector": "LOCAL",
                "authentication": "SINGLE",
                "author": "CNVD",
                "availabilityImpact": "NONE",
                "baseScore": 4.6,
                "confidentialityImpact": "COMPLETE",
                "exploitabilityScore": 3.1,
                "id": "CNVD-2025-29086",
                "impactScore": 6.9,
                "integrityImpact": "NONE",
                "severity": "MEDIUM",
                "trust": 0.6,
                "vectorString": "AV:L/AC:L/Au:S/C:C/I:N/A:N",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "author": "nvd@nist.gov",
                "availabilityImpact": "NONE",
                "baseScore": 5.5,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 1.8,
                "id": "CVE-2025-12114",
                "impactScore": 3.6,
                "integrityImpact": "NONE",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "trust": 1.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N",
                "version": "3.1"
              }
            ],
            "severity": [
              {
                "author": "nvd@nist.gov",
                "id": "CVE-2025-12114",
                "trust": 1.0,
                "value": "MEDIUM"
              },
              {
                "author": "a0340c66-c385-4f8b-991b-3d05f6fd5220",
                "id": "CVE-2025-12114",
                "trust": 1.0,
                "value": "Medium"
              },
              {
                "author": "CNVD",
                "id": "CNVD-2025-29086",
                "trust": 0.6,
                "value": "MEDIUM"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-29086"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-12114"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-12114"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Enabled\u00a0serial console could potentially leak information that might help attacker to find vulnerabilities.This issue affects BLU-IC2: through 1.19.5; BLU-IC4: through 1.19.5. Azure Access Technology BLU-IC2 and Azure Access Technology BLU-IC4 are both network access controllers from Azure Access Technology, Inc., a US-based company. \n\nBoth Azure Access Technology BLU-IC2 and Azure Access Technology BLU-IC4 contain an information disclosure vulnerability caused by a flaw in the serial console. Attackers could exploit this vulnerability to obtain sensitive information",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2025-12114"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2025-29086"
          }
        ],
        "trust": 1.44
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2025-12114",
            "trust": 1.6
          },
          {
            "db": "CNVD",
            "id": "CNVD-2025-29086",
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-29086"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-12114"
          }
        ]
      },
      "id": "VAR-202510-4377",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-29086"
          }
        ],
        "trust": 0.06
      },
      "iot_taxonomy": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "category": [
              "Network device"
            ],
            "sub_category": null,
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-29086"
          }
        ]
      },
      "last_update_date": "2025-11-28T04:21:53.223000Z",
      "patch": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/patch#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "title": "Patch for Azure Access Technology BLU-IC2 and Azure Access Technology BLU-IC4 information disclosure vulnerabilities (CNVD-2025-29086)",
            "trust": 0.6,
            "url": "https://www.cnvd.org.cn/patchInfo/show/756771"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-29086"
          }
        ]
      },
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-1191",
            "trust": 1.0
          }
        ],
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2025-12114"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 1.0,
            "url": "https://azure-access.com/security-advisories"
          },
          {
            "trust": 0.6,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2025-12114"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-29086"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-12114"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-29086"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-12114"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2025-11-20T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2025-29086"
          },
          {
            "date": "2025-10-23T16:15:33.920000",
            "db": "NVD",
            "id": "CVE-2025-12114"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2025-11-20T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2025-29086"
          },
          {
            "date": "2025-11-10T15:08:27.637000",
            "db": "NVD",
            "id": "CVE-2025-12114"
          }
        ]
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Azure Access Technology BLU-IC2 and Azure Access Technology BLU-IC4 information disclosure vulnerabilities (CNVD-2025-29086)",
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-29086"
          }
        ],
        "trust": 0.6
      }
    }

    VAR-202510-4376

    Vulnerability from variot - Updated: 2025-11-25 23:05

    Missing Initial Password Change.This issue affects BLU-IC2: through 1.19.5; BLU-IC4: through 1.19.5. Azure Access Technology BLU-IC2 and Azure Access Technology BLU-IC4 are both network access controllers from Azure Access Technology, Inc., a US-based company.

    A security vulnerability exists in both Azure Access Technology BLU-IC2 and Azure Access Technology BLU-IC4, stemming from a lack of initial password change functionality. Detailed vulnerability information is not currently available

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-202510-4376",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "blu-ic4",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "azure access",
            "version": "1.20"
          },
          {
            "model": "blu-ic2",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "azure access",
            "version": "1.20"
          },
          {
            "model": "access technology blu-ic2",
            "scope": "lte",
            "trust": 0.6,
            "vendor": "azure",
            "version": "\u003c=1.19.5"
          },
          {
            "model": "access technology blu-ic4",
            "scope": "lte",
            "trust": 0.6,
            "vendor": "azure",
            "version": "\u003c=1.19.5"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-29093"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-12285"
          }
        ]
      },
      "cve": "CVE-2025-12285",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "CNVD",
                "availabilityImpact": "COMPLETE",
                "baseScore": 10.0,
                "confidentialityImpact": "COMPLETE",
                "exploitabilityScore": 10.0,
                "id": "CNVD-2025-29093",
                "impactScore": 10.0,
                "integrityImpact": "COMPLETE",
                "severity": "HIGH",
                "trust": 0.6,
                "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "nvd@nist.gov",
                "availabilityImpact": "HIGH",
                "baseScore": 9.8,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 3.9,
                "id": "CVE-2025-12285",
                "impactScore": 5.9,
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "trust": 1.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              }
            ],
            "severity": [
              {
                "author": "nvd@nist.gov",
                "id": "CVE-2025-12285",
                "trust": 1.0,
                "value": "CRITICAL"
              },
              {
                "author": "a0340c66-c385-4f8b-991b-3d05f6fd5220",
                "id": "CVE-2025-12285",
                "trust": 1.0,
                "value": "Critical"
              },
              {
                "author": "CNVD",
                "id": "CNVD-2025-29093",
                "trust": 0.6,
                "value": "HIGH"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-29093"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-12285"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-12285"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Missing Initial Password Change.This issue affects BLU-IC2: through 1.19.5; BLU-IC4: through 1.19.5. Azure Access Technology BLU-IC2 and Azure Access Technology BLU-IC4 are both network access controllers from Azure Access Technology, Inc., a US-based company. \n\nA security vulnerability exists in both Azure Access Technology BLU-IC2 and Azure Access Technology BLU-IC4, stemming from a lack of initial password change functionality. Detailed vulnerability information is not currently available",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2025-12285"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2025-29093"
          }
        ],
        "trust": 1.44
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2025-12285",
            "trust": 1.6
          },
          {
            "db": "CNVD",
            "id": "CNVD-2025-29093",
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-29093"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-12285"
          }
        ]
      },
      "id": "VAR-202510-4376",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-29093"
          }
        ],
        "trust": 0.06
      },
      "iot_taxonomy": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "category": [
              "Network device"
            ],
            "sub_category": null,
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-29093"
          }
        ]
      },
      "last_update_date": "2025-11-25T23:05:21.365000Z",
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-521",
            "trust": 1.0
          },
          {
            "problemtype": "CWE-20",
            "trust": 1.0
          }
        ],
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2025-12285"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 1.0,
            "url": "https://azure-access.com/security-advisories"
          },
          {
            "trust": 0.6,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2025-12285"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-29093"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-12285"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-29093"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-12285"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2025-11-21T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2025-29093"
          },
          {
            "date": "2025-10-26T17:15:52.533000",
            "db": "NVD",
            "id": "CVE-2025-12285"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2025-11-21T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2025-29093"
          },
          {
            "date": "2025-11-10T14:55:30.380000",
            "db": "NVD",
            "id": "CVE-2025-12285"
          }
        ]
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "An unidentified vulnerability exists in Azure Access Technology BLU-IC2 and Azure Access Technology BLU-IC4 (CNVD-2025-29093).",
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-29093"
          }
        ],
        "trust": 0.6
      }
    }

    VAR-202510-3717

    Vulnerability from variot - Updated: 2025-11-25 00:03

    Server Version Disclosure.This issue affects BLU-IC2: through 1.19.5; BLU-IC4: through 1.19.5 . Azure Access Technology BLU-IC2 and Azure Access Technology BLU-IC4 are both network access controllers from Azure Access Technology, Inc., a US-based company.

    Both Azure Access Technology BLU-IC2 and Azure Access Technology BLU-IC4 contain an information disclosure vulnerability caused by incorrect authentication. Attackers could exploit this vulnerability to obtain server version information

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-202510-3717",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "blu-ic2",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "azure access",
            "version": "1.20"
          },
          {
            "model": "blu-ic4",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "azure access",
            "version": "1.20"
          },
          {
            "model": "access technology blu-ic2",
            "scope": "lte",
            "trust": 0.6,
            "vendor": "azure",
            "version": "\u003c=1.19.5"
          },
          {
            "model": "access technology blu-ic4",
            "scope": "lte",
            "trust": 0.6,
            "vendor": "azure",
            "version": "\u003c=1.19.5"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-29077"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-12477"
          }
        ]
      },
      "cve": "CVE-2025-12477",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "CNVD",
                "availabilityImpact": "COMPLETE",
                "baseScore": 10.0,
                "confidentialityImpact": "COMPLETE",
                "exploitabilityScore": 10.0,
                "id": "CNVD-2025-29077",
                "impactScore": 10.0,
                "integrityImpact": "COMPLETE",
                "severity": "HIGH",
                "trust": 0.6,
                "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "nvd@nist.gov",
                "availabilityImpact": "HIGH",
                "baseScore": 9.8,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 3.9,
                "id": "CVE-2025-12477",
                "impactScore": 5.9,
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "trust": 1.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              }
            ],
            "severity": [
              {
                "author": "nvd@nist.gov",
                "id": "CVE-2025-12477",
                "trust": 1.0,
                "value": "CRITICAL"
              },
              {
                "author": "a0340c66-c385-4f8b-991b-3d05f6fd5220",
                "id": "CVE-2025-12477",
                "trust": 1.0,
                "value": "Critical"
              },
              {
                "author": "CNVD",
                "id": "CNVD-2025-29077",
                "trust": 0.6,
                "value": "HIGH"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-29077"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-12477"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-12477"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Server Version Disclosure.This issue affects BLU-IC2: through 1.19.5; BLU-IC4: through 1.19.5 . Azure Access Technology BLU-IC2 and Azure Access Technology BLU-IC4 are both network access controllers from Azure Access Technology, Inc., a US-based company. \n\nBoth Azure Access Technology BLU-IC2 and Azure Access Technology BLU-IC4 contain an information disclosure vulnerability caused by incorrect authentication. Attackers could exploit this vulnerability to obtain server version information",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2025-12477"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2025-29077"
          }
        ],
        "trust": 1.44
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2025-12477",
            "trust": 1.6
          },
          {
            "db": "CNVD",
            "id": "CNVD-2025-29077",
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-29077"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-12477"
          }
        ]
      },
      "id": "VAR-202510-3717",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-29077"
          }
        ],
        "trust": 0.06
      },
      "iot_taxonomy": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "category": [
              "Network device"
            ],
            "sub_category": null,
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-29077"
          }
        ]
      },
      "last_update_date": "2025-11-25T00:03:11.153000Z",
      "patch": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/patch#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "title": "Patch for Azure Access Technology BLU-IC2 and Azure Access Technology BLU-IC4 information disclosure vulnerabilities",
            "trust": 0.6,
            "url": "https://www.cnvd.org.cn/patchInfo/show/756711"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-29077"
          }
        ]
      },
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-306",
            "trust": 1.0
          }
        ],
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2025-12477"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 1.0,
            "url": "https://azure-access.com/security-advisories"
          },
          {
            "trust": 0.6,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2025-12477"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-29077"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-12477"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-29077"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-12477"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2025-11-20T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2025-29077"
          },
          {
            "date": "2025-10-29T17:15:34.627000",
            "db": "NVD",
            "id": "CVE-2025-12477"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2025-11-20T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2025-29077"
          },
          {
            "date": "2025-11-07T14:34:09.533000",
            "db": "NVD",
            "id": "CVE-2025-12477"
          }
        ]
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Azure Access Technology BLU-IC2 and Azure Access Technology BLU-IC4 information disclosure vulnerabilities",
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-29077"
          }
        ],
        "trust": 0.6
      }
    }

    VAR-202510-3391

    Vulnerability from variot - Updated: 2025-11-23 23:58

    Logout Functionality not Working.This issue affects BLU-IC2: through 1.19.5; BLU-IC4: through 1.19.5. Azure Access Technology BLU-IC2 and Azure Access Technology BLU-IC4 are both network access controllers from Azure Access Technology, Inc., a US-based company.

    A security vulnerability exists in both Azure Access Technology BLU-IC2 and Azure Access Technology BLU-IC4, stemming from a malfunction in the logout function. Detailed vulnerability information is not currently available

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-202510-3391",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "blu-ic2",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "azure access",
            "version": "1.20"
          },
          {
            "model": "blu-ic4",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "azure access",
            "version": "1.20"
          },
          {
            "model": "access technology blu-ic2",
            "scope": "lte",
            "trust": 0.6,
            "vendor": "azure",
            "version": "\u003c=1.19.5"
          },
          {
            "model": "access technology blu-ic4",
            "scope": "lte",
            "trust": 0.6,
            "vendor": "azure",
            "version": "\u003c=1.19.5"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-29094"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-12278"
          }
        ]
      },
      "cve": "CVE-2025-12278",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "CNVD",
                "availabilityImpact": "NONE",
                "baseScore": 6.4,
                "confidentialityImpact": "PARTIAL",
                "exploitabilityScore": 10.0,
                "id": "CNVD-2025-29094",
                "impactScore": 4.9,
                "integrityImpact": "PARTIAL",
                "severity": "MEDIUM",
                "trust": 0.6,
                "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:N",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "nvd@nist.gov",
                "availabilityImpact": "NONE",
                "baseScore": 6.5,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "LOW",
                "exploitabilityScore": 3.9,
                "id": "CVE-2025-12278",
                "impactScore": 2.5,
                "integrityImpact": "LOW",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "trust": 1.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:N",
                "version": "3.1"
              }
            ],
            "severity": [
              {
                "author": "nvd@nist.gov",
                "id": "CVE-2025-12278",
                "trust": 1.0,
                "value": "MEDIUM"
              },
              {
                "author": "a0340c66-c385-4f8b-991b-3d05f6fd5220",
                "id": "CVE-2025-12278",
                "trust": 1.0,
                "value": "Medium"
              },
              {
                "author": "CNVD",
                "id": "CNVD-2025-29094",
                "trust": 0.6,
                "value": "MEDIUM"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-29094"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-12278"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-12278"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Logout Functionality not Working.This issue affects BLU-IC2: through 1.19.5; BLU-IC4: through 1.19.5. Azure Access Technology BLU-IC2 and Azure Access Technology BLU-IC4 are both network access controllers from Azure Access Technology, Inc., a US-based company. \n\nA security vulnerability exists in both Azure Access Technology BLU-IC2 and Azure Access Technology BLU-IC4, stemming from a malfunction in the logout function. Detailed vulnerability information is not currently available",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2025-12278"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2025-29094"
          }
        ],
        "trust": 1.44
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2025-12278",
            "trust": 1.6
          },
          {
            "db": "CNVD",
            "id": "CNVD-2025-29094",
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-29094"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-12278"
          }
        ]
      },
      "id": "VAR-202510-3391",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-29094"
          }
        ],
        "trust": 0.06
      },
      "iot_taxonomy": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "category": [
              "Network device"
            ],
            "sub_category": null,
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-29094"
          }
        ]
      },
      "last_update_date": "2025-11-23T23:58:45.670000Z",
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-613",
            "trust": 1.0
          },
          {
            "problemtype": "CWE-20",
            "trust": 1.0
          }
        ],
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2025-12278"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 1.0,
            "url": "https://azure-access.com/security-advisories"
          },
          {
            "trust": 0.6,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2025-12278"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-29094"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-12278"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-29094"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-12278"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2025-11-21T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2025-29094"
          },
          {
            "date": "2025-10-26T17:15:52.180000",
            "db": "NVD",
            "id": "CVE-2025-12278"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2025-11-21T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2025-29094"
          },
          {
            "date": "2025-11-10T14:58:56.403000",
            "db": "NVD",
            "id": "CVE-2025-12278"
          }
        ]
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "An unidentified vulnerability exists in Azure Access Technology BLU-IC2 and Azure Access Technology BLU-IC4 (CNVD-2025-29094).",
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-29094"
          }
        ],
        "trust": 0.6
      }
    }

    VAR-202510-2546

    Vulnerability from variot - Updated: 2025-11-23 23:57

    Outdated and Vulnerable UI Dependencies might potentially lead to exploitation.This issue affects BLU-IC2: through 1.19.5; BLU-IC4: through 1.19.5. Azure Access Technology BLU-IC2 and Azure Access Technology BLU-IC4 are both network access controllers from Azure Access Technology, Inc., a US-based company.

    A security vulnerability exists in both Azure Access Technology BLU-IC2 and Azure Access Technology BLU-IC4. Detailed vulnerability information is not currently available

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-202510-2546",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "blu-ic2",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "azure access",
            "version": "1.20"
          },
          {
            "model": "blu-ic4",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "azure access",
            "version": "1.20"
          },
          {
            "model": "access technology blu-ic2",
            "scope": "lte",
            "trust": 0.6,
            "vendor": "azure",
            "version": "\u003c=1.19.5"
          },
          {
            "model": "access technology blu-ic4",
            "scope": "lte",
            "trust": 0.6,
            "vendor": "azure",
            "version": "\u003c=1.19.5"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-29085"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-12104"
          }
        ]
      },
      "cve": "CVE-2025-12104",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "CNVD",
                "availabilityImpact": "COMPLETE",
                "baseScore": 10.0,
                "confidentialityImpact": "COMPLETE",
                "exploitabilityScore": 10.0,
                "id": "CNVD-2025-29085",
                "impactScore": 10.0,
                "integrityImpact": "COMPLETE",
                "severity": "HIGH",
                "trust": 0.6,
                "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "nvd@nist.gov",
                "availabilityImpact": "HIGH",
                "baseScore": 9.8,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 3.9,
                "id": "CVE-2025-12104",
                "impactScore": 5.9,
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "trust": 1.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              }
            ],
            "severity": [
              {
                "author": "nvd@nist.gov",
                "id": "CVE-2025-12104",
                "trust": 1.0,
                "value": "CRITICAL"
              },
              {
                "author": "a0340c66-c385-4f8b-991b-3d05f6fd5220",
                "id": "CVE-2025-12104",
                "trust": 1.0,
                "value": "Critical"
              },
              {
                "author": "CNVD",
                "id": "CNVD-2025-29085",
                "trust": 0.6,
                "value": "HIGH"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-29085"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-12104"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-12104"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Outdated and Vulnerable UI Dependencies might potentially lead to exploitation.This issue affects BLU-IC2: through 1.19.5; BLU-IC4: through 1.19.5. Azure Access Technology BLU-IC2 and Azure Access Technology BLU-IC4 are both network access controllers from Azure Access Technology, Inc., a US-based company. \n\nA security vulnerability exists in both Azure Access Technology BLU-IC2 and Azure Access Technology BLU-IC4. Detailed vulnerability information is not currently available",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2025-12104"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2025-29085"
          }
        ],
        "trust": 1.44
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2025-12104",
            "trust": 1.6
          },
          {
            "db": "CNVD",
            "id": "CNVD-2025-29085",
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-29085"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-12104"
          }
        ]
      },
      "id": "VAR-202510-2546",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-29085"
          }
        ],
        "trust": 0.06
      },
      "iot_taxonomy": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "category": [
              "Network device"
            ],
            "sub_category": null,
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-29085"
          }
        ]
      },
      "last_update_date": "2025-11-23T23:57:47.230000Z",
      "patch": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/patch#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "title": "Patch for An unidentified vulnerability exists in Azure Access Technology BLU-IC2 and Azure Access Technology BLU-IC4 (CNVD-2025-29085).",
            "trust": 0.6,
            "url": "https://www.cnvd.org.cn/patchInfo/show/756766"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-29085"
          }
        ]
      },
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-1104",
            "trust": 1.0
          }
        ],
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2025-12104"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 1.0,
            "url": "https://azure-access.com/security-advisories"
          },
          {
            "trust": 0.6,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2025-12104"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-29085"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-12104"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-29085"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-12104"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2025-11-20T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2025-29085"
          },
          {
            "date": "2025-10-23T04:15:52",
            "db": "NVD",
            "id": "CVE-2025-12104"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2025-11-20T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2025-29085"
          },
          {
            "date": "2025-11-07T20:05:44.410000",
            "db": "NVD",
            "id": "CVE-2025-12104"
          }
        ]
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "An unidentified vulnerability exists in Azure Access Technology BLU-IC2 and Azure Access Technology BLU-IC4 (CNVD-2025-29085).",
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-29085"
          }
        ],
        "trust": 0.6
      }
    }

    VAR-202510-2966

    Vulnerability from variot - Updated: 2025-11-23 23:57

    Error Messages Wrapped In HTTP Header.This issue affects BLU-IC2: through 1.19.5; BLU-IC4: through 1.19.5. Azure Access Technology BLU-IC2 and Azure Access Technology BLU-IC4 are both network access controllers from Azure Access Technology, Inc., a US-based company.

    Both Azure Access Technology BLU-IC2 and Azure Access Technology BLU-IC4 contain an information disclosure vulnerability caused by an error message wrapped in the HTTP header. An attacker could exploit this vulnerability to obtain sensitive information

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-202510-2966",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "blu-ic4",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "azure access",
            "version": "1.20"
          },
          {
            "model": "blu-ic2",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "azure access",
            "version": "1.20"
          },
          {
            "model": "access technology blu-ic2",
            "scope": "lte",
            "trust": 0.6,
            "vendor": "azure",
            "version": "\u003c=1.19.5"
          },
          {
            "model": "access technology blu-ic4",
            "scope": "lte",
            "trust": 0.6,
            "vendor": "azure",
            "version": "\u003c=1.19.5"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-29150"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-12365"
          }
        ]
      },
      "cve": "CVE-2025-12365",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "CNVD",
                "availabilityImpact": "NONE",
                "baseScore": 5.0,
                "confidentialityImpact": "PARTIAL",
                "exploitabilityScore": 10.0,
                "id": "CNVD-2025-29150",
                "impactScore": 2.9,
                "integrityImpact": "NONE",
                "severity": "MEDIUM",
                "trust": 0.6,
                "vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "nvd@nist.gov",
                "availabilityImpact": "NONE",
                "baseScore": 5.3,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "LOW",
                "exploitabilityScore": 3.9,
                "id": "CVE-2025-12365",
                "impactScore": 1.4,
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "trust": 1.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N",
                "version": "3.1"
              }
            ],
            "severity": [
              {
                "author": "nvd@nist.gov",
                "id": "CVE-2025-12365",
                "trust": 1.0,
                "value": "MEDIUM"
              },
              {
                "author": "a0340c66-c385-4f8b-991b-3d05f6fd5220",
                "id": "CVE-2025-12365",
                "trust": 1.0,
                "value": "Medium"
              },
              {
                "author": "CNVD",
                "id": "CNVD-2025-29150",
                "trust": 0.6,
                "value": "MEDIUM"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-29150"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-12365"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-12365"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Error Messages Wrapped In HTTP Header.This issue affects BLU-IC2: through 1.19.5; BLU-IC4: through 1.19.5. Azure Access Technology BLU-IC2 and Azure Access Technology BLU-IC4 are both network access controllers from Azure Access Technology, Inc., a US-based company. \n\nBoth Azure Access Technology BLU-IC2 and Azure Access Technology BLU-IC4 contain an information disclosure vulnerability caused by an error message wrapped in the HTTP header. An attacker could exploit this vulnerability to obtain sensitive information",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2025-12365"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2025-29150"
          }
        ],
        "trust": 1.44
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2025-12365",
            "trust": 1.6
          },
          {
            "db": "CNVD",
            "id": "CNVD-2025-29150",
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-29150"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-12365"
          }
        ]
      },
      "id": "VAR-202510-2966",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-29150"
          }
        ],
        "trust": 0.06
      },
      "iot_taxonomy": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "category": [
              "Network device"
            ],
            "sub_category": null,
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-29150"
          }
        ]
      },
      "last_update_date": "2025-11-23T23:57:47.202000Z",
      "patch": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/patch#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "title": "Patch for Azure Access Technology BLU-IC2 and Azure Access Technology BLU-IC4 information disclosure vulnerabilities (CNVD-2025-29150)",
            "trust": 0.6,
            "url": "https://www.cnvd.org.cn/patchInfo/show/757201"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-29150"
          }
        ]
      },
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-209",
            "trust": 1.0
          }
        ],
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2025-12365"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 1.0,
            "url": "https://azure-access.com/security-advisories"
          },
          {
            "trust": 0.6,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2025-12365"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-29150"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-12365"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-29150"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-12365"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2025-11-21T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2025-29150"
          },
          {
            "date": "2025-10-27T19:16:02.793000",
            "db": "NVD",
            "id": "CVE-2025-12365"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2025-11-21T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2025-29150"
          },
          {
            "date": "2025-11-10T14:54:12.747000",
            "db": "NVD",
            "id": "CVE-2025-12365"
          }
        ]
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Azure Access Technology BLU-IC2 and Azure Access Technology BLU-IC4 information disclosure vulnerabilities (CNVD-2025-29150)",
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-29150"
          }
        ],
        "trust": 0.6
      }
    }

    VAR-202510-4373

    Vulnerability from variot - Updated: 2025-11-23 23:57

    Busybox 1.31.1 - Multiple Known Vulnerabilities.This issue affects BLU-IC2: through 1.19.5; BLU-IC4: through 1.19.5. Azure Access Technology BLU-IC2 and Azure Access Technology BLU-IC4 are both network access controllers from Azure Access Technology, Inc., a US-based company.

    Both Azure Access Technology BLU-IC2 and Azure Access Technology BLU-IC4 contain a cross-site request forgery (XPS) vulnerability caused by improper validation of user-provided input. An attacker could exploit this vulnerability to perform unauthorized actions by sending malformed HTTP requests

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-202510-4373",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "blu-ic4",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "azure access",
            "version": "1.20"
          },
          {
            "model": "blu-ic2",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "azure access",
            "version": "1.20"
          },
          {
            "model": "access technology blu-ic2",
            "scope": "lte",
            "trust": 0.6,
            "vendor": "azure",
            "version": "\u003c=1.19.5"
          },
          {
            "model": "access technology blu-ic4",
            "scope": "lte",
            "trust": 0.6,
            "vendor": "azure",
            "version": "\u003c=1.19.5"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-29095"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-12221"
          }
        ]
      },
      "cve": "CVE-2025-12221",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "CNVD",
                "availabilityImpact": "COMPLETE",
                "baseScore": 10.0,
                "confidentialityImpact": "COMPLETE",
                "exploitabilityScore": 10.0,
                "id": "CNVD-2025-29095",
                "impactScore": 10.0,
                "integrityImpact": "COMPLETE",
                "severity": "HIGH",
                "trust": 0.6,
                "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "nvd@nist.gov",
                "availabilityImpact": "HIGH",
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 2.8,
                "id": "CVE-2025-12221",
                "impactScore": 5.9,
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "trust": 1.0,
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
                "version": "3.1"
              }
            ],
            "severity": [
              {
                "author": "nvd@nist.gov",
                "id": "CVE-2025-12221",
                "trust": 1.0,
                "value": "HIGH"
              },
              {
                "author": "a0340c66-c385-4f8b-991b-3d05f6fd5220",
                "id": "CVE-2025-12221",
                "trust": 1.0,
                "value": "Low"
              },
              {
                "author": "CNVD",
                "id": "CNVD-2025-29095",
                "trust": 0.6,
                "value": "HIGH"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-29095"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-12221"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-12221"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Busybox 1.31.1 - Multiple Known Vulnerabilities.This issue affects BLU-IC2: through 1.19.5; BLU-IC4: through 1.19.5. Azure Access Technology BLU-IC2 and Azure Access Technology BLU-IC4 are both network access controllers from Azure Access Technology, Inc., a US-based company. \n\nBoth Azure Access Technology BLU-IC2 and Azure Access Technology BLU-IC4 contain a cross-site request forgery (XPS) vulnerability caused by improper validation of user-provided input. An attacker could exploit this vulnerability to perform unauthorized actions by sending malformed HTTP requests",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2025-12221"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2025-29095"
          }
        ],
        "trust": 1.44
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2025-12221",
            "trust": 1.6
          },
          {
            "db": "CNVD",
            "id": "CNVD-2025-29095",
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-29095"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-12221"
          }
        ]
      },
      "id": "VAR-202510-4373",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-29095"
          }
        ],
        "trust": 0.06
      },
      "iot_taxonomy": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "category": [
              "Network device"
            ],
            "sub_category": null,
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-29095"
          }
        ]
      },
      "last_update_date": "2025-11-23T23:57:47.142000Z",
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-16",
            "trust": 1.0
          },
          {
            "problemtype": "CWE-352",
            "trust": 1.0
          }
        ],
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2025-12221"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 1.0,
            "url": "https://azure-access.com/security-advisories"
          },
          {
            "trust": 0.6,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2025-12221"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-29095"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-12221"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-29095"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-12221"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2025-11-21T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2025-29095"
          },
          {
            "date": "2025-10-25T16:15:40.777000",
            "db": "NVD",
            "id": "CVE-2025-12221"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2025-11-21T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2025-29095"
          },
          {
            "date": "2025-11-07T02:08:41.150000",
            "db": "NVD",
            "id": "CVE-2025-12221"
          }
        ]
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Azure Access Technology BLU-IC2 and Azure Access Technology BLU-IC4 Cross-Site Request Forgery Vulnerabilities (CNVD-2025-29095)",
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-29095"
          }
        ],
        "trust": 0.6
      }
    }

    VAR-202510-2967

    Vulnerability from variot - Updated: 2025-11-23 23:57

    Lack of Input Validation in the web UI might lead to potential exploitation.This issue affects BLU-IC2: through 1.19.5; BLU-IC4: through 1.19.5. Azure Access Technology BLU-IC2 and Azure Access Technology BLU-IC4 are both network access controllers from Azure Access Technology, Inc., a US-based company.

    Both Azure Access Technology BLU-IC2 and Azure Access Technology BLU-IC4 contain a cross-site scripting (XSS) vulnerability caused by improper validation of user-supplied input. Detailed vulnerability information is not currently available

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-202510-2967",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "blu-ic4",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "azure access",
            "version": "1.20"
          },
          {
            "model": "blu-ic2",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "azure access",
            "version": "1.20"
          },
          {
            "model": "access technology blu-ic2",
            "scope": "lte",
            "trust": 0.6,
            "vendor": "azure",
            "version": "\u003c=1.19.5"
          },
          {
            "model": "access technology blu-ic4",
            "scope": "lte",
            "trust": 0.6,
            "vendor": "azure",
            "version": "\u003c=1.19.5"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-29147"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-12284"
          }
        ]
      },
      "cve": "CVE-2025-12284",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "CNVD",
                "availabilityImpact": "NONE",
                "baseScore": 6.4,
                "confidentialityImpact": "PARTIAL",
                "exploitabilityScore": 10.0,
                "id": "CNVD-2025-29147",
                "impactScore": 4.9,
                "integrityImpact": "PARTIAL",
                "severity": "MEDIUM",
                "trust": 0.6,
                "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:N",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "nvd@nist.gov",
                "availabilityImpact": "NONE",
                "baseScore": 6.1,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "LOW",
                "exploitabilityScore": 2.8,
                "id": "CVE-2025-12284",
                "impactScore": 2.7,
                "integrityImpact": "LOW",
                "privilegesRequired": "NONE",
                "scope": "CHANGED",
                "trust": 1.0,
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N",
                "version": "3.1"
              }
            ],
            "severity": [
              {
                "author": "nvd@nist.gov",
                "id": "CVE-2025-12284",
                "trust": 1.0,
                "value": "MEDIUM"
              },
              {
                "author": "a0340c66-c385-4f8b-991b-3d05f6fd5220",
                "id": "CVE-2025-12284",
                "trust": 1.0,
                "value": "Medium"
              },
              {
                "author": "CNVD",
                "id": "CNVD-2025-29147",
                "trust": 0.6,
                "value": "MEDIUM"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-29147"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-12284"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-12284"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Lack of Input Validation in the web UI might lead to potential exploitation.This issue affects BLU-IC2: through 1.19.5; BLU-IC4: through 1.19.5. Azure Access Technology BLU-IC2 and Azure Access Technology BLU-IC4 are both network access controllers from Azure Access Technology, Inc., a US-based company. \n\nBoth Azure Access Technology BLU-IC2 and Azure Access Technology BLU-IC4 contain a cross-site scripting (XSS) vulnerability caused by improper validation of user-supplied input. Detailed vulnerability information is not currently available",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2025-12284"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2025-29147"
          }
        ],
        "trust": 1.44
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2025-12284",
            "trust": 1.6
          },
          {
            "db": "CNVD",
            "id": "CNVD-2025-29147",
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-29147"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-12284"
          }
        ]
      },
      "id": "VAR-202510-2967",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-29147"
          }
        ],
        "trust": 0.06
      },
      "iot_taxonomy": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "category": [
              "Network device"
            ],
            "sub_category": null,
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-29147"
          }
        ]
      },
      "last_update_date": "2025-11-23T23:57:22.744000Z",
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-79",
            "trust": 1.0
          },
          {
            "problemtype": "CWE-20",
            "trust": 1.0
          }
        ],
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2025-12284"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 1.0,
            "url": "https://azure-access.com/security-advisories"
          },
          {
            "trust": 0.6,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2025-12284"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-29147"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-12284"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-29147"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-12284"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2025-11-21T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2025-29147"
          },
          {
            "date": "2025-10-26T17:15:52.357000",
            "db": "NVD",
            "id": "CVE-2025-12284"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2025-11-21T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2025-29147"
          },
          {
            "date": "2025-11-10T14:57:42.463000",
            "db": "NVD",
            "id": "CVE-2025-12284"
          }
        ]
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Cross-site scripting vulnerabilities in Azure Access Technology BLU-IC2 and Azure Access Technology BLU-IC4",
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-29147"
          }
        ],
        "trust": 0.6
      }
    }

    VAR-202510-3387

    Vulnerability from variot - Updated: 2025-11-23 23:57

    Non-Compliant TLS Configuration.This issue affects BLU-IC2: through 1.19.5; BLU-IC4: through 1.19.5 . Azure Access Technology BLU-IC2 and Azure Access Technology BLU-IC4 are both network access controllers from Azure Access Technology, Inc., a US-based company.

    Both Azure Access Technology BLU-IC2 and Azure Access Technology BLU-IC4 contain a security vulnerability stemming from non-compliant TLS configuration. Detailed vulnerability information is not currently available

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-202510-3387",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "blu-ic2",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "azure access",
            "version": "1.20"
          },
          {
            "model": "blu-ic4",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "azure access",
            "version": "1.20"
          },
          {
            "model": "access technology blu-ic2",
            "scope": "lte",
            "trust": 0.6,
            "vendor": "azure",
            "version": "\u003c=1.19.5"
          },
          {
            "model": "access technology blu-ic4",
            "scope": "lte",
            "trust": 0.6,
            "vendor": "azure",
            "version": "\u003c=1.19.5"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-29079"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-12478"
          }
        ]
      },
      "cve": "CVE-2025-12478",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "CNVD",
                "availabilityImpact": "COMPLETE",
                "baseScore": 10.0,
                "confidentialityImpact": "COMPLETE",
                "exploitabilityScore": 10.0,
                "id": "CNVD-2025-29079",
                "impactScore": 10.0,
                "integrityImpact": "COMPLETE",
                "severity": "HIGH",
                "trust": 0.6,
                "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "nvd@nist.gov",
                "availabilityImpact": "HIGH",
                "baseScore": 9.8,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 3.9,
                "id": "CVE-2025-12478",
                "impactScore": 5.9,
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "trust": 1.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              }
            ],
            "severity": [
              {
                "author": "nvd@nist.gov",
                "id": "CVE-2025-12478",
                "trust": 1.0,
                "value": "CRITICAL"
              },
              {
                "author": "a0340c66-c385-4f8b-991b-3d05f6fd5220",
                "id": "CVE-2025-12478",
                "trust": 1.0,
                "value": "Critical"
              },
              {
                "author": "CNVD",
                "id": "CNVD-2025-29079",
                "trust": 0.6,
                "value": "HIGH"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-29079"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-12478"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-12478"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Non-Compliant TLS Configuration.This issue affects BLU-IC2: through 1.19.5; BLU-IC4: through 1.19.5 . Azure Access Technology BLU-IC2 and Azure Access Technology BLU-IC4 are both network access controllers from Azure Access Technology, Inc., a US-based company. \n\nBoth Azure Access Technology BLU-IC2 and Azure Access Technology BLU-IC4 contain a security vulnerability stemming from non-compliant TLS configuration. Detailed vulnerability information is not currently available",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2025-12478"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2025-29079"
          }
        ],
        "trust": 1.44
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2025-12478",
            "trust": 1.6
          },
          {
            "db": "CNVD",
            "id": "CNVD-2025-29079",
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-29079"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-12478"
          }
        ]
      },
      "id": "VAR-202510-3387",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-29079"
          }
        ],
        "trust": 0.06
      },
      "iot_taxonomy": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "category": [
              "Network device"
            ],
            "sub_category": null,
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-29079"
          }
        ]
      },
      "last_update_date": "2025-11-23T23:57:22.717000Z",
      "patch": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/patch#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "title": "Patch for An unidentified vulnerability exists in Azure Access Technology BLU-IC2 and Azure Access Technology BLU-IC4 (CNVD-2025-29079).",
            "trust": 0.6,
            "url": "https://www.cnvd.org.cn/patchInfo/show/756736"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-29079"
          }
        ]
      },
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-326",
            "trust": 1.0
          }
        ],
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2025-12478"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 1.0,
            "url": "https://azure-access.com/security-advisories"
          },
          {
            "trust": 0.6,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2025-12478"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-29079"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-12478"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-29079"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-12478"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2025-11-20T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2025-29079"
          },
          {
            "date": "2025-10-29T17:15:34.993000",
            "db": "NVD",
            "id": "CVE-2025-12478"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2025-11-20T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2025-29079"
          },
          {
            "date": "2025-11-07T13:51:33.857000",
            "db": "NVD",
            "id": "CVE-2025-12478"
          }
        ]
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "An unidentified vulnerability exists in Azure Access Technology BLU-IC2 and Azure Access Technology BLU-IC4 (CNVD-2025-29079).",
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-29079"
          }
        ],
        "trust": 0.6
      }
    }

    VAR-202510-4374

    Vulnerability from variot - Updated: 2025-11-23 23:57

    Weak Password Policy.This issue affects BLU-IC2: through 1.19.5; BLU-IC4: through 1.19.5. Azure Access Technology BLU-IC2 and Azure Access Technology BLU-IC4 are both network access controllers from Azure Access Technology, Inc., a US-based company.

    Both Azure Access Technology BLU-IC2 and Azure Access Technology BLU-IC4 contain a security vulnerability stemming from a weak password policy. Detailed vulnerability information is not currently available

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-202510-4374",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "blu-ic4",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "azure access",
            "version": "1.20"
          },
          {
            "model": "blu-ic2",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "azure access",
            "version": "1.20"
          },
          {
            "model": "access technology blu-ic2",
            "scope": "lte",
            "trust": 0.6,
            "vendor": "azure",
            "version": "\u003c=1.19.5"
          },
          {
            "model": "access technology blu-ic4",
            "scope": "lte",
            "trust": 0.6,
            "vendor": "azure",
            "version": "\u003c=1.19.5"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-29151"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-12364"
          }
        ]
      },
      "cve": "CVE-2025-12364",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "CNVD",
                "availabilityImpact": "COMPLETE",
                "baseScore": 10.0,
                "confidentialityImpact": "COMPLETE",
                "exploitabilityScore": 10.0,
                "id": "CNVD-2025-29151",
                "impactScore": 10.0,
                "integrityImpact": "COMPLETE",
                "severity": "HIGH",
                "trust": 0.6,
                "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "nvd@nist.gov",
                "availabilityImpact": "HIGH",
                "baseScore": 9.8,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 3.9,
                "id": "CVE-2025-12364",
                "impactScore": 5.9,
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "trust": 1.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              }
            ],
            "severity": [
              {
                "author": "nvd@nist.gov",
                "id": "CVE-2025-12364",
                "trust": 1.0,
                "value": "CRITICAL"
              },
              {
                "author": "a0340c66-c385-4f8b-991b-3d05f6fd5220",
                "id": "CVE-2025-12364",
                "trust": 1.0,
                "value": "Critical"
              },
              {
                "author": "CNVD",
                "id": "CNVD-2025-29151",
                "trust": 0.6,
                "value": "HIGH"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-29151"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-12364"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-12364"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Weak Password Policy.This issue affects BLU-IC2: through 1.19.5; BLU-IC4: through 1.19.5. Azure Access Technology BLU-IC2 and Azure Access Technology BLU-IC4 are both network access controllers from Azure Access Technology, Inc., a US-based company. \n\nBoth Azure Access Technology BLU-IC2 and Azure Access Technology BLU-IC4 contain a security vulnerability stemming from a weak password policy. Detailed vulnerability information is not currently available",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2025-12364"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2025-29151"
          }
        ],
        "trust": 1.44
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2025-12364",
            "trust": 1.6
          },
          {
            "db": "CNVD",
            "id": "CNVD-2025-29151",
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-29151"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-12364"
          }
        ]
      },
      "id": "VAR-202510-4374",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-29151"
          }
        ],
        "trust": 0.06
      },
      "iot_taxonomy": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "category": [
              "Network device"
            ],
            "sub_category": null,
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-29151"
          }
        ]
      },
      "last_update_date": "2025-11-23T23:57:22.673000Z",
      "patch": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/patch#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "title": "Patch for An unidentified vulnerability exists in Azure Access Technology BLU-IC2 and Azure Access Technology BLU-IC4 (CNVD-2025-29151).",
            "trust": 0.6,
            "url": "https://www.cnvd.org.cn/patchInfo/show/757226"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-29151"
          }
        ]
      },
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-521",
            "trust": 1.0
          }
        ],
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2025-12364"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 1.0,
            "url": "https://azure-access.com/security-advisories"
          },
          {
            "trust": 0.6,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2025-12364"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-29151"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-12364"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-29151"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-12364"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2025-11-21T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2025-29151"
          },
          {
            "date": "2025-10-27T18:15:38.857000",
            "db": "NVD",
            "id": "CVE-2025-12364"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2025-11-21T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2025-29151"
          },
          {
            "date": "2025-11-10T14:54:46.497000",
            "db": "NVD",
            "id": "CVE-2025-12364"
          }
        ]
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "An unidentified vulnerability exists in Azure Access Technology BLU-IC2 and Azure Access Technology BLU-IC4 (CNVD-2025-29151).",
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-29151"
          }
        ],
        "trust": 0.6
      }
    }

    VAR-202510-3184

    Vulnerability from variot - Updated: 2025-11-23 23:56

    Credits Page not Matching Versions in Use in the FirmwareThis issue affects BLU-IC2: through 1.19.5; BLU-IC4: through 1.19.5 . Azure Access Technology BLU-IC2 and Azure Access Technology BLU-IC4 are both network access controllers from Azure Access Technology, Inc., a US-based company.

    Both Azure Access Technology BLU-IC2 and Azure Access Technology BLU-IC4 contain a security vulnerability stemming from a firmware version mismatch. Detailed vulnerability information is not currently available

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-202510-3184",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "blu-ic4",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "azure access",
            "version": "1.20"
          },
          {
            "model": "blu-ic2",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "azure access",
            "version": "1.20"
          },
          {
            "model": "access technology blu-ic2",
            "scope": "lte",
            "trust": 0.6,
            "vendor": "azure",
            "version": "\u003c=1.19.5"
          },
          {
            "model": "access technology blu-ic4",
            "scope": "lte",
            "trust": 0.6,
            "vendor": "azure",
            "version": "\u003c=1.19.5"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-29075"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-12517"
          }
        ]
      },
      "cve": "CVE-2025-12517",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "CNVD",
                "availabilityImpact": "NONE",
                "baseScore": 5.0,
                "confidentialityImpact": "NONE",
                "exploitabilityScore": 10.0,
                "id": "CNVD-2025-29075",
                "impactScore": 2.9,
                "integrityImpact": "PARTIAL",
                "severity": "MEDIUM",
                "trust": 0.6,
                "vectorString": "AV:N/AC:L/Au:N/C:N/I:P/A:N",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "nvd@nist.gov",
                "availabilityImpact": "NONE",
                "baseScore": 5.3,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "NONE",
                "exploitabilityScore": 3.9,
                "id": "CVE-2025-12517",
                "impactScore": 1.4,
                "integrityImpact": "LOW",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "trust": 1.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:N",
                "version": "3.1"
              }
            ],
            "severity": [
              {
                "author": "nvd@nist.gov",
                "id": "CVE-2025-12517",
                "trust": 1.0,
                "value": "MEDIUM"
              },
              {
                "author": "a0340c66-c385-4f8b-991b-3d05f6fd5220",
                "id": "CVE-2025-12517",
                "trust": 1.0,
                "value": "Low"
              },
              {
                "author": "CNVD",
                "id": "CNVD-2025-29075",
                "trust": 0.6,
                "value": "MEDIUM"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-29075"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-12517"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-12517"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Credits Page not Matching Versions in Use in the FirmwareThis issue affects BLU-IC2: through 1.19.5; BLU-IC4: through 1.19.5 . Azure Access Technology BLU-IC2 and Azure Access Technology BLU-IC4 are both network access controllers from Azure Access Technology, Inc., a US-based company. \n\nBoth Azure Access Technology BLU-IC2 and Azure Access Technology BLU-IC4 contain a security vulnerability stemming from a firmware version mismatch. Detailed vulnerability information is not currently available",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2025-12517"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2025-29075"
          }
        ],
        "trust": 1.44
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2025-12517",
            "trust": 1.6
          },
          {
            "db": "CNVD",
            "id": "CNVD-2025-29075",
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-29075"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-12517"
          }
        ]
      },
      "id": "VAR-202510-3184",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-29075"
          }
        ],
        "trust": 0.06
      },
      "iot_taxonomy": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "category": [
              "Network device"
            ],
            "sub_category": null,
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-29075"
          }
        ]
      },
      "last_update_date": "2025-11-23T23:56:00.410000Z",
      "patch": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/patch#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "title": "Patch for An unidentified vulnerability exists in Azure Access Technology BLU-IC2 and Azure Access Technology BLU-IC4 (CNVD-2025-29075).",
            "trust": 0.6,
            "url": "https://www.cnvd.org.cn/patchInfo/show/756701"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-29075"
          }
        ]
      },
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-448",
            "trust": 1.0
          }
        ],
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2025-12517"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 1.0,
            "url": "https://azure-access.com/security-advisories"
          },
          {
            "trust": 0.6,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2025-12517"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-29075"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-12517"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-29075"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-12517"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2025-11-20T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2025-29075"
          },
          {
            "date": "2025-10-30T16:15:35.257000",
            "db": "NVD",
            "id": "CVE-2025-12517"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2025-11-20T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2025-29075"
          },
          {
            "date": "2025-11-10T14:51:37.207000",
            "db": "NVD",
            "id": "CVE-2025-12517"
          }
        ]
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "An unidentified vulnerability exists in Azure Access Technology BLU-IC2 and Azure Access Technology BLU-IC4 (CNVD-2025-29075).",
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-29075"
          }
        ],
        "trust": 0.6
      }
    }

    VAR-202510-3719

    Vulnerability from variot - Updated: 2025-11-23 23:54

    Email Password Disclosure.This issue affects BLU-IC2: through 1.19.5; BLU-IC4: through 1.19.5. Azure Access Technology BLU-IC2 and Azure Access Technology BLU-IC4 are both network access controllers from Azure Access Technology, Inc., a US-based company.

    Both Azure Access Technology BLU-IC2 and Azure Access Technology BLU-IC4 contain an information disclosure vulnerability caused by improper authorization verification. An attacker could exploit this vulnerability to obtain email password information

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-202510-3719",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "blu-ic4",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "azure access",
            "version": "1.20"
          },
          {
            "model": "blu-ic2",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "azure access",
            "version": "1.20"
          },
          {
            "model": "access technology blu-ic2",
            "scope": "lte",
            "trust": 0.6,
            "vendor": "azure",
            "version": "\u003c=1.19.5"
          },
          {
            "model": "access technology blu-ic4",
            "scope": "lte",
            "trust": 0.6,
            "vendor": "azure",
            "version": "\u003c=1.19.5"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-29149"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-12363"
          }
        ]
      },
      "cve": "CVE-2025-12363",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "CNVD",
                "availabilityImpact": "NONE",
                "baseScore": 7.8,
                "confidentialityImpact": "COMPLETE",
                "exploitabilityScore": 10.0,
                "id": "CNVD-2025-29149",
                "impactScore": 6.9,
                "integrityImpact": "NONE",
                "severity": "HIGH",
                "trust": 0.6,
                "vectorString": "AV:N/AC:L/Au:N/C:C/I:N/A:N",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "nvd@nist.gov",
                "availabilityImpact": "NONE",
                "baseScore": 7.5,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 3.9,
                "id": "CVE-2025-12363",
                "impactScore": 3.6,
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "trust": 1.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
                "version": "3.1"
              }
            ],
            "severity": [
              {
                "author": "nvd@nist.gov",
                "id": "CVE-2025-12363",
                "trust": 1.0,
                "value": "HIGH"
              },
              {
                "author": "a0340c66-c385-4f8b-991b-3d05f6fd5220",
                "id": "CVE-2025-12363",
                "trust": 1.0,
                "value": "Critical"
              },
              {
                "author": "CNVD",
                "id": "CNVD-2025-29149",
                "trust": 0.6,
                "value": "HIGH"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-29149"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-12363"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-12363"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Email Password Disclosure.This issue affects BLU-IC2: through 1.19.5; BLU-IC4: through 1.19.5. Azure Access Technology BLU-IC2 and Azure Access Technology BLU-IC4 are both network access controllers from Azure Access Technology, Inc., a US-based company. \n\nBoth Azure Access Technology BLU-IC2 and Azure Access Technology BLU-IC4 contain an information disclosure vulnerability caused by improper authorization verification. An attacker could exploit this vulnerability to obtain email password information",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2025-12363"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2025-29149"
          }
        ],
        "trust": 1.44
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2025-12363",
            "trust": 1.6
          },
          {
            "db": "CNVD",
            "id": "CNVD-2025-29149",
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-29149"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-12363"
          }
        ]
      },
      "id": "VAR-202510-3719",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-29149"
          }
        ],
        "trust": 0.06
      },
      "iot_taxonomy": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "category": [
              "Network device"
            ],
            "sub_category": null,
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-29149"
          }
        ]
      },
      "last_update_date": "2025-11-23T23:54:46.533000Z",
      "patch": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/patch#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "title": "Patch for Azure Access Technology BLU-IC2 and Azure Access Technology BLU-IC4 information disclosure vulnerabilities (CNVD-2025-29149)",
            "trust": 0.6,
            "url": "https://www.cnvd.org.cn/patchInfo/show/757191"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-29149"
          }
        ]
      },
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-200",
            "trust": 1.0
          }
        ],
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2025-12363"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 1.0,
            "url": "https://azure-access.com/security-advisories"
          },
          {
            "trust": 0.6,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2025-12363"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-29149"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-12363"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-29149"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-12363"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2025-11-21T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2025-29149"
          },
          {
            "date": "2025-10-27T18:15:38.223000",
            "db": "NVD",
            "id": "CVE-2025-12363"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2025-11-21T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2025-29149"
          },
          {
            "date": "2025-11-10T14:54:57.490000",
            "db": "NVD",
            "id": "CVE-2025-12363"
          }
        ]
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Azure Access Technology BLU-IC2 and Azure Access Technology BLU-IC4 information disclosure vulnerabilities (CNVD-2025-29149)",
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-29149"
          }
        ],
        "trust": 0.6
      }
    }

    VAR-202510-4097

    Vulnerability from variot - Updated: 2025-11-23 23:54

    Systemic Internal Server Errors - HTTP 500 ResponseThis issue affects BLU-IC2: through 1.19.5; BLU-IC4: through 1.19.5 . Azure Access Technology BLU-IC2 and Azure Access Technology BLU-IC4 are both network access controllers from Azure Access Technology, Inc., a US-based company.

    Both Azure Access Technology BLU-IC2 and Azure Access Technology BLU-IC4 contain a denial-of-service vulnerability stemming from an internal server error. An attacker could exploit this vulnerability to cause an HTTP 500 response

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-202510-4097",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "blu-ic4",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "azure access",
            "version": "1.20"
          },
          {
            "model": "blu-ic2",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "azure access",
            "version": "1.20"
          },
          {
            "model": "access technology blu-ic2",
            "scope": "lte",
            "trust": 0.6,
            "vendor": "azure",
            "version": "\u003c=1.19.5"
          },
          {
            "model": "access technology blu-ic4",
            "scope": "lte",
            "trust": 0.6,
            "vendor": "azure",
            "version": "\u003c=1.19.5"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-29074"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-12515"
          }
        ]
      },
      "cve": "CVE-2025-12515",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "CNVD",
                "availabilityImpact": "COMPLETE",
                "baseScore": 10.0,
                "confidentialityImpact": "COMPLETE",
                "exploitabilityScore": 10.0,
                "id": "CNVD-2025-29074",
                "impactScore": 10.0,
                "integrityImpact": "COMPLETE",
                "severity": "HIGH",
                "trust": 0.6,
                "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "nvd@nist.gov",
                "availabilityImpact": "HIGH",
                "baseScore": 9.8,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 3.9,
                "id": "CVE-2025-12515",
                "impactScore": 5.9,
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "trust": 1.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              }
            ],
            "severity": [
              {
                "author": "nvd@nist.gov",
                "id": "CVE-2025-12515",
                "trust": 1.0,
                "value": "CRITICAL"
              },
              {
                "author": "a0340c66-c385-4f8b-991b-3d05f6fd5220",
                "id": "CVE-2025-12515",
                "trust": 1.0,
                "value": "Critical"
              },
              {
                "author": "CNVD",
                "id": "CNVD-2025-29074",
                "trust": 0.6,
                "value": "HIGH"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-29074"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-12515"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-12515"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Systemic Internal Server Errors - HTTP 500 ResponseThis issue affects BLU-IC2: through 1.19.5; BLU-IC4: through 1.19.5 . Azure Access Technology BLU-IC2 and Azure Access Technology BLU-IC4 are both network access controllers from Azure Access Technology, Inc., a US-based company. \n\nBoth Azure Access Technology BLU-IC2 and Azure Access Technology BLU-IC4 contain a denial-of-service vulnerability stemming from an internal server error. An attacker could exploit this vulnerability to cause an HTTP 500 response",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2025-12515"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2025-29074"
          }
        ],
        "trust": 1.44
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2025-12515",
            "trust": 1.6
          },
          {
            "db": "CNVD",
            "id": "CNVD-2025-29074",
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-29074"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-12515"
          }
        ]
      },
      "id": "VAR-202510-4097",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-29074"
          }
        ],
        "trust": 0.06
      },
      "iot_taxonomy": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "category": [
              "Network device"
            ],
            "sub_category": null,
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-29074"
          }
        ]
      },
      "last_update_date": "2025-11-23T23:54:46.507000Z",
      "patch": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/patch#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "title": "Patch for Azure Access Technology BLU-IC2 and Azure Access Technology BLU-IC4 Denial-of-Service Vulnerabilities (CNVD-2025-29074)",
            "trust": 0.6,
            "url": "https://www.cnvd.org.cn/patchInfo/show/756696"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-29074"
          }
        ]
      },
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-394",
            "trust": 1.0
          }
        ],
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2025-12515"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 1.0,
            "url": "https://azure-access.com/security-advisories"
          },
          {
            "trust": 0.6,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2025-12515"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-29074"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-12515"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-29074"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-12515"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2025-11-20T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2025-29074"
          },
          {
            "date": "2025-10-30T16:15:34.960000",
            "db": "NVD",
            "id": "CVE-2025-12515"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2025-11-20T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2025-29074"
          },
          {
            "date": "2025-11-10T14:53:32.310000",
            "db": "NVD",
            "id": "CVE-2025-12515"
          }
        ]
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Azure Access Technology BLU-IC2 and Azure Access Technology BLU-IC4 Denial-of-Service Vulnerabilities (CNVD-2025-29074)",
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-29074"
          }
        ],
        "trust": 0.6
      }
    }

    VAR-202510-2979

    Vulnerability from variot - Updated: 2025-11-23 23:53

    Allocation of Resources Without Limits or Throttling vulnerability in Azure Access Technology BLU-IC2, Azure Access Technology BLU-IC4 allows Flooding.This issue affects BLU-IC2: through 1.19.5; BLU-IC4: through 1.19.5. Attackers could exploit this vulnerability to launch a flood attack

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-202510-2979",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "blu-ic2",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "azure access",
            "version": "1.20"
          },
          {
            "model": "blu-ic4",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "azure access",
            "version": "1.20"
          },
          {
            "model": "access technology blu-ic2",
            "scope": "gte",
            "trust": 0.6,
            "vendor": "azure",
            "version": "1.0,\u003c=1.19.5"
          },
          {
            "model": "access technology blu-ic4",
            "scope": "gte",
            "trust": 0.6,
            "vendor": "azure",
            "version": "1.0,\u003c=1.19.5"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-29155"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-11832"
          }
        ]
      },
      "cve": "CVE-2025-11832",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "CNVD",
                "availabilityImpact": "COMPLETE",
                "baseScore": 10.0,
                "confidentialityImpact": "COMPLETE",
                "exploitabilityScore": 10.0,
                "id": "CNVD-2025-29155",
                "impactScore": 10.0,
                "integrityImpact": "COMPLETE",
                "severity": "HIGH",
                "trust": 0.6,
                "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "nvd@nist.gov",
                "availabilityImpact": "HIGH",
                "baseScore": 9.8,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 3.9,
                "id": "CVE-2025-11832",
                "impactScore": 5.9,
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "trust": 1.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              }
            ],
            "severity": [
              {
                "author": "nvd@nist.gov",
                "id": "CVE-2025-11832",
                "trust": 1.0,
                "value": "CRITICAL"
              },
              {
                "author": "a0340c66-c385-4f8b-991b-3d05f6fd5220",
                "id": "CVE-2025-11832",
                "trust": 1.0,
                "value": "Critical"
              },
              {
                "author": "CNVD",
                "id": "CNVD-2025-29155",
                "trust": 0.6,
                "value": "HIGH"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-29155"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-11832"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-11832"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Allocation of Resources Without Limits or Throttling vulnerability in Azure Access Technology BLU-IC2, Azure Access Technology BLU-IC4 allows Flooding.This issue affects BLU-IC2: through 1.19.5; BLU-IC4: through 1.19.5. Attackers could exploit this vulnerability to launch a flood attack",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2025-11832"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2025-29155"
          }
        ],
        "trust": 1.44
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2025-11832",
            "trust": 1.6
          },
          {
            "db": "CNVD",
            "id": "CNVD-2025-29155",
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-29155"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-11832"
          }
        ]
      },
      "id": "VAR-202510-2979",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-29155"
          }
        ],
        "trust": 0.06
      },
      "iot_taxonomy": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "category": [
              "Network device"
            ],
            "sub_category": null,
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-29155"
          }
        ]
      },
      "last_update_date": "2025-11-23T23:53:02.738000Z",
      "patch": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/patch#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "title": "Patch for An unidentified vulnerability exists in Azure Access Technology BLU-IC2 and Azure Access Technology BLU-IC4 (CNVD-2025-29155).",
            "trust": 0.6,
            "url": "https://www.cnvd.org.cn/patchInfo/show/757261"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-29155"
          }
        ]
      },
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-770",
            "trust": 1.0
          }
        ],
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2025-11832"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 1.0,
            "url": "https://azure-access.com/security-advisories"
          },
          {
            "trust": 0.6,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2025-11832"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-29155"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-11832"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-29155"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-11832"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2025-11-21T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2025-29155"
          },
          {
            "date": "2025-10-15T19:15:31.623000",
            "db": "NVD",
            "id": "CVE-2025-11832"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2025-11-21T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2025-29155"
          },
          {
            "date": "2025-11-07T17:49:51.360000",
            "db": "NVD",
            "id": "CVE-2025-11832"
          }
        ]
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "An unidentified vulnerability exists in Azure Access Technology BLU-IC2 and Azure Access Technology BLU-IC4 (CNVD-2025-29155).",
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-29155"
          }
        ],
        "trust": 0.6
      }
    }

    VAR-202510-2968

    Vulnerability from variot - Updated: 2025-11-23 23:52

    Mail Configuration File Manipulation + Command Execution.This issue affects BLU-IC2: through 1.19.5; BLU-IC4: through 1.19.5. Azure Access Technology BLU-IC2 and Azure Access Technology BLU-IC4 are both network access controllers from Azure Access Technology, Inc., a US-based company.

    A command execution vulnerability exists in both Azure Access Technology BLU-IC2 and Azure Access Technology BLU-IC4, caused by improper input validation. An attacker could exploit this vulnerability to execute arbitrary commands and manipulate email configurations

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-202510-2968",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "blu-ic4",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "azure access",
            "version": "1.20"
          },
          {
            "model": "blu-ic2",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "azure access",
            "version": "1.20"
          },
          {
            "model": "access technology blu-ic2",
            "scope": "lte",
            "trust": 0.6,
            "vendor": "azure",
            "version": "\u003c=1.19.5"
          },
          {
            "model": "access technology blu-ic4",
            "scope": "lte",
            "trust": 0.6,
            "vendor": "azure",
            "version": "\u003c=1.19.5"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-29148"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-12275"
          }
        ]
      },
      "cve": "CVE-2025-12275",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "CNVD",
                "availabilityImpact": "COMPLETE",
                "baseScore": 10.0,
                "confidentialityImpact": "COMPLETE",
                "exploitabilityScore": 10.0,
                "id": "CNVD-2025-29148",
                "impactScore": 10.0,
                "integrityImpact": "COMPLETE",
                "severity": "HIGH",
                "trust": 0.6,
                "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "nvd@nist.gov",
                "availabilityImpact": "HIGH",
                "baseScore": 9.8,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 3.9,
                "id": "CVE-2025-12275",
                "impactScore": 5.9,
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "trust": 1.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              }
            ],
            "severity": [
              {
                "author": "nvd@nist.gov",
                "id": "CVE-2025-12275",
                "trust": 1.0,
                "value": "CRITICAL"
              },
              {
                "author": "a0340c66-c385-4f8b-991b-3d05f6fd5220",
                "id": "CVE-2025-12275",
                "trust": 1.0,
                "value": "Critical"
              },
              {
                "author": "CNVD",
                "id": "CNVD-2025-29148",
                "trust": 0.6,
                "value": "HIGH"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-29148"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-12275"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-12275"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Mail Configuration File Manipulation + Command Execution.This issue affects BLU-IC2: through 1.19.5; BLU-IC4: through 1.19.5. Azure Access Technology BLU-IC2 and Azure Access Technology BLU-IC4 are both network access controllers from Azure Access Technology, Inc., a US-based company. \n\nA command execution vulnerability exists in both Azure Access Technology BLU-IC2 and Azure Access Technology BLU-IC4, caused by improper input validation. An attacker could exploit this vulnerability to execute arbitrary commands and manipulate email configurations",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2025-12275"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2025-29148"
          }
        ],
        "trust": 1.44
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2025-12275",
            "trust": 1.6
          },
          {
            "db": "CNVD",
            "id": "CNVD-2025-29148",
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-29148"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-12275"
          }
        ]
      },
      "id": "VAR-202510-2968",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-29148"
          }
        ],
        "trust": 0.06
      },
      "iot_taxonomy": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "category": [
              "Network device"
            ],
            "sub_category": null,
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-29148"
          }
        ]
      },
      "last_update_date": "2025-11-23T23:52:06.384000Z",
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-20",
            "trust": 1.0
          },
          {
            "problemtype": "NVD-CWE-noinfo",
            "trust": 1.0
          }
        ],
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2025-12275"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 1.0,
            "url": "https://azure-access.com/security-advisories"
          },
          {
            "trust": 0.6,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2025-12275"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-29148"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-12275"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-29148"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-12275"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2025-11-21T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2025-29148"
          },
          {
            "date": "2025-10-26T17:15:51.237000",
            "db": "NVD",
            "id": "CVE-2025-12275"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2025-11-21T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2025-29148"
          },
          {
            "date": "2025-11-07T02:06:35.190000",
            "db": "NVD",
            "id": "CVE-2025-12275"
          }
        ]
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Command execution vulnerabilities in Azure Access Technology BLU-IC2 and Azure Access Technology BLU-IC4",
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-29148"
          }
        ],
        "trust": 0.6
      }
    }

    VAR-202510-3388

    Vulnerability from variot - Updated: 2025-11-23 23:52

    Privilege Escalation through SUID-bit Binary.This issue affects BLU-IC2: through 1.19.5; BLU-IC4: through 1.19.5 . Azure Access Technology BLU-IC2 and Azure Access Technology BLU-IC4 are both network access controllers from Azure Access Technology, Inc., a US-based company.

    Both Azure Access Technology BLU-IC2 and Azure Access Technology BLU-IC4 contain a privilege escalation vulnerability caused by improper privilege management in the SUID bit binary. An attacker could exploit this vulnerability to gain elevated privileges on the system

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-202510-3388",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "blu-ic2",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "azure access",
            "version": "1.20"
          },
          {
            "model": "blu-ic4",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "azure access",
            "version": "1.20"
          },
          {
            "model": "access technology blu-ic2",
            "scope": "lte",
            "trust": 0.6,
            "vendor": "azure",
            "version": "\u003c=1.19.5"
          },
          {
            "model": "access technology blu-ic4",
            "scope": "lte",
            "trust": 0.6,
            "vendor": "azure",
            "version": "\u003c=1.19.5"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-29084"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-12424"
          }
        ]
      },
      "cve": "CVE-2025-12424",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "CNVD",
                "availabilityImpact": "COMPLETE",
                "baseScore": 10.0,
                "confidentialityImpact": "COMPLETE",
                "exploitabilityScore": 10.0,
                "id": "CNVD-2025-29084",
                "impactScore": 10.0,
                "integrityImpact": "COMPLETE",
                "severity": "HIGH",
                "trust": 0.6,
                "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "nvd@nist.gov",
                "availabilityImpact": "HIGH",
                "baseScore": 9.8,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 3.9,
                "id": "CVE-2025-12424",
                "impactScore": 5.9,
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "trust": 1.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              }
            ],
            "severity": [
              {
                "author": "nvd@nist.gov",
                "id": "CVE-2025-12424",
                "trust": 1.0,
                "value": "CRITICAL"
              },
              {
                "author": "a0340c66-c385-4f8b-991b-3d05f6fd5220",
                "id": "CVE-2025-12424",
                "trust": 1.0,
                "value": "Critical"
              },
              {
                "author": "CNVD",
                "id": "CNVD-2025-29084",
                "trust": 0.6,
                "value": "HIGH"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-29084"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-12424"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-12424"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Privilege Escalation through SUID-bit Binary.This issue affects BLU-IC2: through 1.19.5; BLU-IC4: through 1.19.5 . Azure Access Technology BLU-IC2 and Azure Access Technology BLU-IC4 are both network access controllers from Azure Access Technology, Inc., a US-based company. \n\nBoth Azure Access Technology BLU-IC2 and Azure Access Technology BLU-IC4 contain a privilege escalation vulnerability caused by improper privilege management in the SUID bit binary. An attacker could exploit this vulnerability to gain elevated privileges on the system",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2025-12424"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2025-29084"
          }
        ],
        "trust": 1.44
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2025-12424",
            "trust": 1.6
          },
          {
            "db": "CNVD",
            "id": "CNVD-2025-29084",
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-29084"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-12424"
          }
        ]
      },
      "id": "VAR-202510-3388",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-29084"
          }
        ],
        "trust": 0.06
      },
      "iot_taxonomy": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "category": [
              "Network device"
            ],
            "sub_category": null,
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-29084"
          }
        ]
      },
      "last_update_date": "2025-11-23T23:52:06.356000Z",
      "patch": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/patch#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "title": "Patch for Azure Access Technology BLU-IC2 and Azure Access Technology BLU-IC4 privilege escalation vulnerabilities (CNVD-2025-29084)",
            "trust": 0.6,
            "url": "https://www.cnvd.org.cn/patchInfo/show/756761"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-29084"
          }
        ]
      },
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-269",
            "trust": 1.0
          }
        ],
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2025-12424"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 1.0,
            "url": "https://azure-access.com/security-advisories"
          },
          {
            "trust": 0.6,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2025-12424"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-29084"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-12424"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-29084"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-12424"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2025-11-20T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2025-29084"
          },
          {
            "date": "2025-10-28T19:15:41.403000",
            "db": "NVD",
            "id": "CVE-2025-12424"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2025-11-20T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2025-29084"
          },
          {
            "date": "2025-11-07T14:45:20.907000",
            "db": "NVD",
            "id": "CVE-2025-12424"
          }
        ]
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Azure Access Technology BLU-IC2 and Azure Access Technology BLU-IC4 privilege escalation vulnerabilities (CNVD-2025-29084)",
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-29084"
          }
        ],
        "trust": 0.6
      }
    }

    VAR-202510-4375

    Vulnerability from variot - Updated: 2025-11-23 23:51

    Vulnerable Upgrade Feature (Arbitrary File Write) may lead to obtaining super user permissions on board.This issue affects BLU-IC2: through 1.19.5; BLU-IC4: through 1.19.5. Azure Access Technology BLU-IC2 and Azure Access Technology BLU-IC4 are both network access controllers from Azure Access Technology, Inc., a US-based company.

    Both Azure Access Technology BLU-IC2 and Azure Access Technology BLU-IC4 contain a privilege escalation vulnerability caused by an arbitrary file write flaw in the escalation feature. An attacker could exploit this vulnerability to gain escalated privileges on the system

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-202510-4375",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "blu-ic2",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "azure access",
            "version": "1.20"
          },
          {
            "model": "blu-ic4",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "azure access",
            "version": "1.20"
          },
          {
            "model": "access technology blu-ic2",
            "scope": "lte",
            "trust": 0.6,
            "vendor": "azure",
            "version": "\u003c=1.19.5"
          },
          {
            "model": "access technology blu-ic4",
            "scope": "lte",
            "trust": 0.6,
            "vendor": "azure",
            "version": "\u003c=1.19.5"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-29083"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-12422"
          }
        ]
      },
      "cve": "CVE-2025-12422",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "CNVD",
                "availabilityImpact": "COMPLETE",
                "baseScore": 10.0,
                "confidentialityImpact": "COMPLETE",
                "exploitabilityScore": 10.0,
                "id": "CNVD-2025-29083",
                "impactScore": 10.0,
                "integrityImpact": "COMPLETE",
                "severity": "HIGH",
                "trust": 0.6,
                "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "nvd@nist.gov",
                "availabilityImpact": "HIGH",
                "baseScore": 9.8,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 3.9,
                "id": "CVE-2025-12422",
                "impactScore": 5.9,
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "trust": 1.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              }
            ],
            "severity": [
              {
                "author": "nvd@nist.gov",
                "id": "CVE-2025-12422",
                "trust": 1.0,
                "value": "CRITICAL"
              },
              {
                "author": "a0340c66-c385-4f8b-991b-3d05f6fd5220",
                "id": "CVE-2025-12422",
                "trust": 1.0,
                "value": "Critical"
              },
              {
                "author": "CNVD",
                "id": "CNVD-2025-29083",
                "trust": 0.6,
                "value": "HIGH"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-29083"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-12422"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-12422"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Vulnerable Upgrade Feature (Arbitrary File Write) may lead to obtaining super user permissions on board.This issue affects BLU-IC2: through 1.19.5; BLU-IC4: through 1.19.5. Azure Access Technology BLU-IC2 and Azure Access Technology BLU-IC4 are both network access controllers from Azure Access Technology, Inc., a US-based company. \n\nBoth Azure Access Technology BLU-IC2 and Azure Access Technology BLU-IC4 contain a privilege escalation vulnerability caused by an arbitrary file write flaw in the escalation feature. An attacker could exploit this vulnerability to gain escalated privileges on the system",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2025-12422"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2025-29083"
          }
        ],
        "trust": 1.44
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2025-12422",
            "trust": 1.6
          },
          {
            "db": "CNVD",
            "id": "CNVD-2025-29083",
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-29083"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-12422"
          }
        ]
      },
      "id": "VAR-202510-4375",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-29083"
          }
        ],
        "trust": 0.06
      },
      "iot_taxonomy": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "category": [
              "Network device"
            ],
            "sub_category": null,
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-29083"
          }
        ]
      },
      "last_update_date": "2025-11-23T23:51:01.558000Z",
      "patch": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/patch#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "title": "Patch for Azure Access Technology BLU-IC2 and Azure Access Technology BLU-IC4 privilege escalation vulnerabilities (CNVD-2025-29083)",
            "trust": 0.6,
            "url": "https://www.cnvd.org.cn/patchInfo/show/756756"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-29083"
          }
        ]
      },
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-22",
            "trust": 1.0
          }
        ],
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2025-12422"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 1.0,
            "url": "https://azure-access.com/security-advisories"
          },
          {
            "trust": 0.6,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2025-12422"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-29083"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-12422"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-29083"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-12422"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2025-11-20T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2025-29083"
          },
          {
            "date": "2025-10-28T18:15:36.697000",
            "db": "NVD",
            "id": "CVE-2025-12422"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2025-11-20T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2025-29083"
          },
          {
            "date": "2025-11-07T14:55:47.233000",
            "db": "NVD",
            "id": "CVE-2025-12422"
          }
        ]
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Azure Access Technology BLU-IC2 and Azure Access Technology BLU-IC4 privilege escalation vulnerabilities (CNVD-2025-29083)",
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-29083"
          }
        ],
        "trust": 0.6
      }
    }

    VAR-202510-2969

    Vulnerability from variot - Updated: 2025-11-23 23:50

    Busybox 1.31.1 - Multiple Known Vulnerabilities.This issue affects BLU-IC2: through 1.19.5; BLU-IC4: through 1.19.5. Azure Access Technology BLU-IC2 and Azure Access Technology BLU-IC4 are both network access controllers from Azure Access Technology, Inc., a US-based company.

    A security vulnerability exists in both Azure Access Technology BLU-IC2 and Azure Access Technology BLU-IC4, stemming from their reliance on the vulnerable third-party component Busybox. Detailed vulnerability information is not currently available

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-202510-2969",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "blu-ic2",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "azure access",
            "version": "1.20"
          },
          {
            "model": "blu-ic4",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "azure access",
            "version": "1.20"
          },
          {
            "model": "access technology blu-ic2",
            "scope": "lte",
            "trust": 0.6,
            "vendor": "azure",
            "version": "\u003c=1.19.5"
          },
          {
            "model": "access technology blu-ic4",
            "scope": "lte",
            "trust": 0.6,
            "vendor": "azure",
            "version": "\u003c=1.19.5"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-29091"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-12220"
          }
        ]
      },
      "cve": "CVE-2025-12220",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "CNVD",
                "availabilityImpact": "COMPLETE",
                "baseScore": 10.0,
                "confidentialityImpact": "COMPLETE",
                "exploitabilityScore": 10.0,
                "id": "CNVD-2025-29091",
                "impactScore": 10.0,
                "integrityImpact": "COMPLETE",
                "severity": "HIGH",
                "trust": 0.6,
                "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "nvd@nist.gov",
                "availabilityImpact": "HIGH",
                "baseScore": 9.8,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 3.9,
                "id": "CVE-2025-12220",
                "impactScore": 5.9,
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "trust": 1.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              }
            ],
            "severity": [
              {
                "author": "nvd@nist.gov",
                "id": "CVE-2025-12220",
                "trust": 1.0,
                "value": "CRITICAL"
              },
              {
                "author": "a0340c66-c385-4f8b-991b-3d05f6fd5220",
                "id": "CVE-2025-12220",
                "trust": 1.0,
                "value": "Critical"
              },
              {
                "author": "CNVD",
                "id": "CNVD-2025-29091",
                "trust": 0.6,
                "value": "HIGH"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-29091"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-12220"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-12220"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Busybox 1.31.1 - Multiple Known Vulnerabilities.This issue affects BLU-IC2: through 1.19.5; BLU-IC4: through 1.19.5. Azure Access Technology BLU-IC2 and Azure Access Technology BLU-IC4 are both network access controllers from Azure Access Technology, Inc., a US-based company. \n\nA security vulnerability exists in both Azure Access Technology BLU-IC2 and Azure Access Technology BLU-IC4, stemming from their reliance on the vulnerable third-party component Busybox. Detailed vulnerability information is not currently available",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2025-12220"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2025-29091"
          }
        ],
        "trust": 1.44
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2025-12220",
            "trust": 1.6
          },
          {
            "db": "CNVD",
            "id": "CNVD-2025-29091",
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-29091"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-12220"
          }
        ]
      },
      "id": "VAR-202510-2969",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-29091"
          }
        ],
        "trust": 0.06
      },
      "iot_taxonomy": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "category": [
              "Network device"
            ],
            "sub_category": null,
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-29091"
          }
        ]
      },
      "last_update_date": "2025-11-23T23:50:07.226000Z",
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "NVD-CWE-noinfo",
            "trust": 1.0
          }
        ],
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2025-12220"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 1.0,
            "url": "https://azure-access.com/security-advisories"
          },
          {
            "trust": 0.6,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2025-12220"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-29091"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-12220"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-29091"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-12220"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2025-11-21T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2025-29091"
          },
          {
            "date": "2025-10-25T16:15:40.660000",
            "db": "NVD",
            "id": "CVE-2025-12220"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2025-11-21T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2025-29091"
          },
          {
            "date": "2025-11-10T15:00:44.853000",
            "db": "NVD",
            "id": "CVE-2025-12220"
          }
        ]
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "An unidentified vulnerability exists in Azure Access Technology BLU-IC2 and Azure Access Technology BLU-IC4 (CNVD-2025-29091).",
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-29091"
          }
        ],
        "trust": 0.6
      }
    }

    VAR-202510-3515

    Vulnerability from variot - Updated: 2025-11-23 23:50

    Missing Security Headers.This issue affects BLU-IC2: through 1.19.5; BLU-IC4: through 1.19.5. Azure Access Technology BLU-IC2 and Azure Access Technology BLU-IC4 are both network access controllers from Azure Access Technology, Inc., a US-based company.

    A security vulnerability exists in both Azure Access Technology BLU-IC2 and Azure Access Technology BLU-IC4, stemming from a missing security header. Detailed vulnerability information is not currently available

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-202510-3515",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "blu-ic4",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "azure access",
            "version": "1.20"
          },
          {
            "model": "blu-ic2",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "azure access",
            "version": "1.20"
          },
          {
            "model": "access technology blu-ic2",
            "scope": "lte",
            "trust": 0.6,
            "vendor": "azure",
            "version": "\u003c=1.19.5"
          },
          {
            "model": "access technology blu-ic4",
            "scope": "lte",
            "trust": 0.6,
            "vendor": "azure",
            "version": "\u003c=1.19.5"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-29071"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-12554"
          }
        ]
      },
      "cve": "CVE-2025-12554",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "CNVD",
                "availabilityImpact": "COMPLETE",
                "baseScore": 10.0,
                "confidentialityImpact": "COMPLETE",
                "exploitabilityScore": 10.0,
                "id": "CNVD-2025-29071",
                "impactScore": 10.0,
                "integrityImpact": "COMPLETE",
                "severity": "HIGH",
                "trust": 0.6,
                "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "nvd@nist.gov",
                "availabilityImpact": "HIGH",
                "baseScore": 9.8,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 3.9,
                "id": "CVE-2025-12554",
                "impactScore": 5.9,
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "trust": 1.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              }
            ],
            "severity": [
              {
                "author": "nvd@nist.gov",
                "id": "CVE-2025-12554",
                "trust": 1.0,
                "value": "CRITICAL"
              },
              {
                "author": "a0340c66-c385-4f8b-991b-3d05f6fd5220",
                "id": "CVE-2025-12554",
                "trust": 1.0,
                "value": "Medium"
              },
              {
                "author": "CNVD",
                "id": "CNVD-2025-29071",
                "trust": 0.6,
                "value": "HIGH"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-29071"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-12554"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-12554"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Missing Security Headers.This issue affects BLU-IC2: through 1.19.5; BLU-IC4: through 1.19.5. Azure Access Technology BLU-IC2 and Azure Access Technology BLU-IC4 are both network access controllers from Azure Access Technology, Inc., a US-based company. \n\nA security vulnerability exists in both Azure Access Technology BLU-IC2 and Azure Access Technology BLU-IC4, stemming from a missing security header. Detailed vulnerability information is not currently available",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2025-12554"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2025-29071"
          }
        ],
        "trust": 1.44
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2025-12554",
            "trust": 1.6
          },
          {
            "db": "CNVD",
            "id": "CNVD-2025-29071",
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-29071"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-12554"
          }
        ]
      },
      "id": "VAR-202510-3515",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-29071"
          }
        ],
        "trust": 0.06
      },
      "iot_taxonomy": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "category": [
              "Network device"
            ],
            "sub_category": null,
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-29071"
          }
        ]
      },
      "last_update_date": "2025-11-23T23:50:07.194000Z",
      "patch": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/patch#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "title": "Patch for An undiscovered vulnerability exists in Azure Access Technology BLU-IC2 and Azure Access Technology BLU-IC4 (CNVD-2025-29071).",
            "trust": 0.6,
            "url": "https://www.cnvd.org.cn/patchInfo/show/756676"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-29071"
          }
        ]
      },
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-693",
            "trust": 1.0
          }
        ],
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2025-12554"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 1.0,
            "url": "https://azure-access.com/security-advisories"
          },
          {
            "trust": 0.6,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2025-12554"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-29071"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-12554"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-29071"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-12554"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2025-11-20T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2025-29071"
          },
          {
            "date": "2025-10-31T16:15:40.170000",
            "db": "NVD",
            "id": "CVE-2025-12554"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2025-11-20T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2025-29071"
          },
          {
            "date": "2025-11-10T14:48:02.390000",
            "db": "NVD",
            "id": "CVE-2025-12554"
          }
        ]
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "An undiscovered vulnerability exists in Azure Access Technology BLU-IC2 and Azure Access Technology BLU-IC4 (CNVD-2025-29071).",
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-29071"
          }
        ],
        "trust": 0.6
      }
    }

    VAR-202510-3385

    Vulnerability from variot - Updated: 2025-11-23 23:49

    Email Server Certificate Verification Disabled.This issue affects BLU-IC2: through 1.19.5; BLU-IC4: through 1.19.5. Azure Access Technology BLU-IC2 and Azure Access Technology BLU-IC4 are both network access controllers from Azure Access Technology, Inc., a US-based company.

    Both Azure Access Technology BLU-IC2 and Azure Access Technology BLU-IC4 contain a security vulnerability stemming from the disabling of email server certificate verification. Attackers could exploit this vulnerability to launch a man-in-the-middle attack

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-202510-3385",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "blu-ic4",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "azure access",
            "version": "1.20"
          },
          {
            "model": "blu-ic2",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "azure access",
            "version": "1.20"
          },
          {
            "model": "access technology blu-ic2",
            "scope": "lte",
            "trust": 0.6,
            "vendor": "azure",
            "version": "\u003c=1.19.5"
          },
          {
            "model": "access technology blu-ic4",
            "scope": "lte",
            "trust": 0.6,
            "vendor": "azure",
            "version": "\u003c=1.19.5"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-29076"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-12553"
          }
        ]
      },
      "cve": "CVE-2025-12553",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "CNVD",
                "availabilityImpact": "COMPLETE",
                "baseScore": 10.0,
                "confidentialityImpact": "COMPLETE",
                "exploitabilityScore": 10.0,
                "id": "CNVD-2025-29076",
                "impactScore": 10.0,
                "integrityImpact": "COMPLETE",
                "severity": "HIGH",
                "trust": 0.6,
                "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "nvd@nist.gov",
                "availabilityImpact": "HIGH",
                "baseScore": 9.8,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 3.9,
                "id": "CVE-2025-12553",
                "impactScore": 5.9,
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "trust": 1.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              }
            ],
            "severity": [
              {
                "author": "nvd@nist.gov",
                "id": "CVE-2025-12553",
                "trust": 1.0,
                "value": "CRITICAL"
              },
              {
                "author": "a0340c66-c385-4f8b-991b-3d05f6fd5220",
                "id": "CVE-2025-12553",
                "trust": 1.0,
                "value": "Critical"
              },
              {
                "author": "CNVD",
                "id": "CNVD-2025-29076",
                "trust": 0.6,
                "value": "HIGH"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-29076"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-12553"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-12553"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Email Server Certificate Verification Disabled.This issue affects BLU-IC2: through 1.19.5; BLU-IC4: through 1.19.5. Azure Access Technology BLU-IC2 and Azure Access Technology BLU-IC4 are both network access controllers from Azure Access Technology, Inc., a US-based company. \n\nBoth Azure Access Technology BLU-IC2 and Azure Access Technology BLU-IC4 contain a security vulnerability stemming from the disabling of email server certificate verification. Attackers could exploit this vulnerability to launch a man-in-the-middle attack",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2025-12553"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2025-29076"
          }
        ],
        "trust": 1.44
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2025-12553",
            "trust": 1.6
          },
          {
            "db": "CNVD",
            "id": "CNVD-2025-29076",
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-29076"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-12553"
          }
        ]
      },
      "id": "VAR-202510-3385",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-29076"
          }
        ],
        "trust": 0.06
      },
      "iot_taxonomy": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "category": [
              "Network device"
            ],
            "sub_category": null,
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-29076"
          }
        ]
      },
      "last_update_date": "2025-11-23T23:49:02.655000Z",
      "patch": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/patch#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "title": "Patch for An undiscovered vulnerability exists in Azure Access Technology BLU-IC2 and Azure Access Technology BLU-IC4 (CNVD-2025-29076).",
            "trust": 0.6,
            "url": "https://www.cnvd.org.cn/patchInfo/show/756706"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-29076"
          }
        ]
      },
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-599",
            "trust": 1.0
          }
        ],
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2025-12553"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 1.0,
            "url": "https://azure-access.com/security-advisories"
          },
          {
            "trust": 0.6,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2025-12553"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-29076"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-12553"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-29076"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-12553"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2025-11-20T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2025-29076"
          },
          {
            "date": "2025-10-31T16:15:40.033000",
            "db": "NVD",
            "id": "CVE-2025-12553"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2025-11-20T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2025-29076"
          },
          {
            "date": "2025-11-10T14:48:31.427000",
            "db": "NVD",
            "id": "CVE-2025-12553"
          }
        ]
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "An undiscovered vulnerability exists in Azure Access Technology BLU-IC2 and Azure Access Technology BLU-IC4 (CNVD-2025-29076).",
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-29076"
          }
        ],
        "trust": 0.6
      }
    }

    VAR-202510-2976

    Vulnerability from variot - Updated: 2025-11-23 23:47

    Incorrect Content-Type header in one of the APIs (text/html instead of application/json) replies may potentially allow injection of HTML/JavaScript into reply.This issue affects BLU-IC2: through 1.19.5; BLU-IC4: through 1.19.5. Azure Access Technology BLU-IC2 and Azure Access Technology BLU-IC4 are both network access controllers from Azure Access Technology, Inc., a US-based company.

    Both Azure Access Technology BLU-IC2 and Azure Access Technology BLU-IC4 contain a security vulnerability stemming from improperly configured Content-Type headers in API responses. Attackers could exploit this vulnerability to inject HTML or JavaScript data

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-202510-2976",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "blu-ic2",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "azure access",
            "version": "1.20"
          },
          {
            "model": "blu-ic4",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "azure access",
            "version": "1.20"
          },
          {
            "model": "access technology blu-ic2",
            "scope": "lte",
            "trust": 0.6,
            "vendor": "azure",
            "version": "\u003c=1.19.5"
          },
          {
            "model": "access technology blu-ic4",
            "scope": "lte",
            "trust": 0.6,
            "vendor": "azure",
            "version": "\u003c=1.19.5"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-29152"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-11925"
          }
        ]
      },
      "cve": "CVE-2025-11925",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "CNVD",
                "availabilityImpact": "NONE",
                "baseScore": 6.4,
                "confidentialityImpact": "PARTIAL",
                "exploitabilityScore": 10.0,
                "id": "CNVD-2025-29152",
                "impactScore": 4.9,
                "integrityImpact": "PARTIAL",
                "severity": "MEDIUM",
                "trust": 0.6,
                "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:N",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "nvd@nist.gov",
                "availabilityImpact": "NONE",
                "baseScore": 6.1,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "LOW",
                "exploitabilityScore": 2.8,
                "id": "CVE-2025-11925",
                "impactScore": 2.7,
                "integrityImpact": "LOW",
                "privilegesRequired": "NONE",
                "scope": "CHANGED",
                "trust": 1.0,
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N",
                "version": "3.1"
              }
            ],
            "severity": [
              {
                "author": "nvd@nist.gov",
                "id": "CVE-2025-11925",
                "trust": 1.0,
                "value": "MEDIUM"
              },
              {
                "author": "a0340c66-c385-4f8b-991b-3d05f6fd5220",
                "id": "CVE-2025-11925",
                "trust": 1.0,
                "value": "Critical"
              },
              {
                "author": "CNVD",
                "id": "CNVD-2025-29152",
                "trust": 0.6,
                "value": "MEDIUM"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-29152"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-11925"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-11925"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Incorrect Content-Type header in one of the APIs (`text/html` instead of `application/json`) replies may potentially allow injection of HTML/JavaScript into reply.This issue affects BLU-IC2: through 1.19.5; BLU-IC4: through 1.19.5. Azure Access Technology BLU-IC2 and Azure Access Technology BLU-IC4 are both network access controllers from Azure Access Technology, Inc., a US-based company. \n\nBoth Azure Access Technology BLU-IC2 and Azure Access Technology BLU-IC4 contain a security vulnerability stemming from improperly configured Content-Type headers in API responses. Attackers could exploit this vulnerability to inject HTML or JavaScript data",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2025-11925"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2025-29152"
          }
        ],
        "trust": 1.44
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2025-11925",
            "trust": 1.6
          },
          {
            "db": "CNVD",
            "id": "CNVD-2025-29152",
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-29152"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-11925"
          }
        ]
      },
      "id": "VAR-202510-2976",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-29152"
          }
        ],
        "trust": 0.06
      },
      "iot_taxonomy": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "category": [
              "Network device"
            ],
            "sub_category": null,
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-29152"
          }
        ]
      },
      "last_update_date": "2025-11-23T23:47:07.417000Z",
      "patch": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/patch#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "title": "Patch for An unidentified vulnerability exists in Azure Access Technology BLU-IC2 and Azure Access Technology BLU-IC4 (CNVD-2025-29152).",
            "trust": 0.6,
            "url": "https://www.cnvd.org.cn/patchInfo/show/757256"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-29152"
          }
        ]
      },
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-754",
            "trust": 1.0
          }
        ],
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2025-11925"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 1.0,
            "url": "https://azure-access.com/security-advisories"
          },
          {
            "trust": 0.6,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2025-11925"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-29152"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-11925"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-29152"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-11925"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2025-11-21T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2025-29152"
          },
          {
            "date": "2025-10-17T20:15:38.610000",
            "db": "NVD",
            "id": "CVE-2025-11925"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2025-11-21T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2025-29152"
          },
          {
            "date": "2025-11-07T17:14:51.093000",
            "db": "NVD",
            "id": "CVE-2025-11925"
          }
        ]
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "An unidentified vulnerability exists in Azure Access Technology BLU-IC2 and Azure Access Technology BLU-IC4 (CNVD-2025-29152).",
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-29152"
          }
        ],
        "trust": 0.6
      }
    }

    VAR-202510-3185

    Vulnerability from variot - Updated: 2025-11-23 23:44

    SNMP Default Community String (public).This issue affects BLU-IC2: through 1.19.5; BLU-IC4: through 1.19.5. Azure Access Technology BLU-IC2 and Azure Access Technology BLU-IC4 are both network access controllers from Azure Access Technology, Inc., a US-based company.

    Both Azure Access Technology BLU-IC2 and Azure Access Technology BLU-IC4 contain a security vulnerability stemming from the use of a default SNMP community string. An attacker could exploit this vulnerability to gain unauthorized access

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-202510-3185",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "blu-ic2",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "azure access",
            "version": "1.20"
          },
          {
            "model": "blu-ic4",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "azure access",
            "version": "1.20"
          },
          {
            "model": "access technology blu-ic2",
            "scope": "lte",
            "trust": 0.6,
            "vendor": "azure",
            "version": "\u003c=1.19.5"
          },
          {
            "model": "access technology blu-ic4",
            "scope": "lte",
            "trust": 0.6,
            "vendor": "azure",
            "version": "\u003c=1.19.5"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-29092"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-12217"
          }
        ]
      },
      "cve": "CVE-2025-12217",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "CNVD",
                "availabilityImpact": "NONE",
                "baseScore": 9.4,
                "confidentialityImpact": "COMPLETE",
                "exploitabilityScore": 10.0,
                "id": "CNVD-2025-29092",
                "impactScore": 9.2,
                "integrityImpact": "COMPLETE",
                "severity": "HIGH",
                "trust": 0.6,
                "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:N",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "nvd@nist.gov",
                "availabilityImpact": "NONE",
                "baseScore": 9.1,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 3.9,
                "id": "CVE-2025-12217",
                "impactScore": 5.2,
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "trust": 1.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N",
                "version": "3.1"
              }
            ],
            "severity": [
              {
                "author": "nvd@nist.gov",
                "id": "CVE-2025-12217",
                "trust": 1.0,
                "value": "CRITICAL"
              },
              {
                "author": "a0340c66-c385-4f8b-991b-3d05f6fd5220",
                "id": "CVE-2025-12217",
                "trust": 1.0,
                "value": "Medium"
              },
              {
                "author": "CNVD",
                "id": "CNVD-2025-29092",
                "trust": 0.6,
                "value": "HIGH"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-29092"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-12217"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-12217"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "SNMP Default Community String (public).This issue affects BLU-IC2: through 1.19.5; BLU-IC4: through 1.19.5. Azure Access Technology BLU-IC2 and Azure Access Technology BLU-IC4 are both network access controllers from Azure Access Technology, Inc., a US-based company. \n\nBoth Azure Access Technology BLU-IC2 and Azure Access Technology BLU-IC4 contain a security vulnerability stemming from the use of a default SNMP community string. An attacker could exploit this vulnerability to gain unauthorized access",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2025-12217"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2025-29092"
          }
        ],
        "trust": 1.44
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2025-12217",
            "trust": 1.6
          },
          {
            "db": "CNVD",
            "id": "CNVD-2025-29092",
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-29092"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-12217"
          }
        ]
      },
      "id": "VAR-202510-3185",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-29092"
          }
        ],
        "trust": 0.06
      },
      "iot_taxonomy": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "category": [
              "Network device"
            ],
            "sub_category": null,
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-29092"
          }
        ]
      },
      "last_update_date": "2025-11-23T23:44:46.498000Z",
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-1392",
            "trust": 1.0
          }
        ],
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2025-12217"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 1.0,
            "url": "https://azure-access.com/security-advisories"
          },
          {
            "trust": 0.6,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2025-12217"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-29092"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-12217"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-29092"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-12217"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2025-11-21T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2025-29092"
          },
          {
            "date": "2025-10-25T16:15:40.243000",
            "db": "NVD",
            "id": "CVE-2025-12217"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2025-11-21T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2025-29092"
          },
          {
            "date": "2025-11-10T15:03:28.133000",
            "db": "NVD",
            "id": "CVE-2025-12217"
          }
        ]
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "An unidentified vulnerability exists in Azure Access Technology BLU-IC2 and Azure Access Technology BLU-IC4 (CNVD-2025-29092).",
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-29092"
          }
        ],
        "trust": 0.6
      }
    }

    VAR-202510-2770

    Vulnerability from variot - Updated: 2025-11-23 23:41

    Malicious / Malformed App can be Installed but not Uninstalled/may lead to unavailability.This issue affects BLU-IC2: through 1.19.5; BLU-IC4: through 1.19.5. Azure Access Technology BLU-IC2 and Azure Access Technology BLU-IC4 are both network access controllers from Azure Access Technology, Inc., a US-based company.

    Both Azure Access Technology BLU-IC2 and Azure Access Technology BLU-IC4 contain a denial-of-service vulnerability. This vulnerability stems from the fact that malicious or malformed applications can be installed but not uninstalled, allowing attackers to exploit this vulnerability to render the service unavailable

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-202510-2770",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "blu-ic2",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "azure access",
            "version": "1.20"
          },
          {
            "model": "blu-ic4",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "azure access",
            "version": "1.20"
          },
          {
            "model": "access technology blu-ic2",
            "scope": "lte",
            "trust": 0.6,
            "vendor": "azure",
            "version": "\u003c=1.19.5"
          },
          {
            "model": "access technology blu-ic4",
            "scope": "lte",
            "trust": 0.6,
            "vendor": "azure",
            "version": "\u003c=1.19.5"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-29089"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-12216"
          }
        ]
      },
      "cve": "CVE-2025-12216",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "accessComplexity": "LOW",
                "accessVector": "LOCAL",
                "authentication": "NONE",
                "author": "CNVD",
                "availabilityImpact": "COMPLETE",
                "baseScore": 4.9,
                "confidentialityImpact": "NONE",
                "exploitabilityScore": 3.9,
                "id": "CNVD-2025-29089",
                "impactScore": 6.9,
                "integrityImpact": "NONE",
                "severity": "MEDIUM",
                "trust": 0.6,
                "vectorString": "AV:L/AC:L/Au:N/C:N/I:N/A:C",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "author": "nvd@nist.gov",
                "availabilityImpact": "HIGH",
                "baseScore": 5.5,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "NONE",
                "exploitabilityScore": 1.8,
                "id": "CVE-2025-12216",
                "impactScore": 3.6,
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "trust": 1.0,
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:H",
                "version": "3.1"
              }
            ],
            "severity": [
              {
                "author": "nvd@nist.gov",
                "id": "CVE-2025-12216",
                "trust": 1.0,
                "value": "MEDIUM"
              },
              {
                "author": "a0340c66-c385-4f8b-991b-3d05f6fd5220",
                "id": "CVE-2025-12216",
                "trust": 1.0,
                "value": "Critical"
              },
              {
                "author": "CNVD",
                "id": "CNVD-2025-29089",
                "trust": 0.6,
                "value": "MEDIUM"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-29089"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-12216"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-12216"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Malicious / Malformed App can be Installed but not Uninstalled/may lead to unavailability.This issue affects BLU-IC2: through 1.19.5; BLU-IC4: through 1.19.5. Azure Access Technology BLU-IC2 and Azure Access Technology BLU-IC4 are both network access controllers from Azure Access Technology, Inc., a US-based company. \n\nBoth Azure Access Technology BLU-IC2 and Azure Access Technology BLU-IC4 contain a denial-of-service vulnerability. This vulnerability stems from the fact that malicious or malformed applications can be installed but not uninstalled, allowing attackers to exploit this vulnerability to render the service unavailable",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2025-12216"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2025-29089"
          }
        ],
        "trust": 1.44
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2025-12216",
            "trust": 1.6
          },
          {
            "db": "CNVD",
            "id": "CNVD-2025-29089",
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-29089"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-12216"
          }
        ]
      },
      "id": "VAR-202510-2770",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-29089"
          }
        ],
        "trust": 0.06
      },
      "iot_taxonomy": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "category": [
              "Network device"
            ],
            "sub_category": null,
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-29089"
          }
        ]
      },
      "last_update_date": "2025-11-23T23:41:28.189000Z",
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-1301",
            "trust": 1.0
          }
        ],
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2025-12216"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 1.0,
            "url": "https://azure-access.com/security-advisories"
          },
          {
            "trust": 0.6,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2025-12216"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-29089"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-12216"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-29089"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-12216"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2025-11-20T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2025-29089"
          },
          {
            "date": "2025-10-25T16:15:39.277000",
            "db": "NVD",
            "id": "CVE-2025-12216"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2025-11-20T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2025-29089"
          },
          {
            "date": "2025-11-10T15:04:53.567000",
            "db": "NVD",
            "id": "CVE-2025-12216"
          }
        ]
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Azure Access Technology BLU-IC2 and Azure Access Technology BLU-IC4 Denial-of-Service Vulnerabilities (CNVD-2025-29089)",
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-29089"
          }
        ],
        "trust": 0.6
      }
    }

    VAR-202510-4200

    Vulnerability from variot - Updated: 2025-11-23 23:41

    Local Privilege Escalation.This issue affects BLU-IC2: through 1.19.5; BLU-IC4: through 1.19.5 . Azure Access Technology BLU-IC2 and Azure Access Technology BLU-IC4 are both network access controllers from Azure Access Technology, Inc., a US-based company.

    Both Azure Access Technology BLU-IC2 and Azure Access Technology BLU-IC4 contain a privilege escalation vulnerability caused by improper privilege management. An attacker could exploit this vulnerability to achieve local privilege escalation

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-202510-4200",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "blu-ic2",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "azure access",
            "version": "1.20"
          },
          {
            "model": "blu-ic4",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "azure access",
            "version": "1.20"
          },
          {
            "model": "access technology blu-ic2",
            "scope": "lte",
            "trust": 0.6,
            "vendor": "azure",
            "version": "\u003c=1.19.5"
          },
          {
            "model": "access technology blu-ic4",
            "scope": "lte",
            "trust": 0.6,
            "vendor": "azure",
            "version": "\u003c=1.19.5"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-29081"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-12425"
          }
        ]
      },
      "cve": "CVE-2025-12425",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "accessComplexity": "LOW",
                "accessVector": "LOCAL",
                "authentication": "SINGLE",
                "author": "CNVD",
                "availabilityImpact": "COMPLETE",
                "baseScore": 6.8,
                "confidentialityImpact": "COMPLETE",
                "exploitabilityScore": 3.1,
                "id": "CNVD-2025-29081",
                "impactScore": 10.0,
                "integrityImpact": "COMPLETE",
                "severity": "MEDIUM",
                "trust": 0.6,
                "vectorString": "AV:L/AC:L/Au:S/C:C/I:C/A:C",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "author": "nvd@nist.gov",
                "availabilityImpact": "HIGH",
                "baseScore": 7.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 1.8,
                "id": "CVE-2025-12425",
                "impactScore": 5.9,
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "trust": 1.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              }
            ],
            "severity": [
              {
                "author": "nvd@nist.gov",
                "id": "CVE-2025-12425",
                "trust": 1.0,
                "value": "HIGH"
              },
              {
                "author": "a0340c66-c385-4f8b-991b-3d05f6fd5220",
                "id": "CVE-2025-12425",
                "trust": 1.0,
                "value": "Critical"
              },
              {
                "author": "CNVD",
                "id": "CNVD-2025-29081",
                "trust": 0.6,
                "value": "MEDIUM"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-29081"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-12425"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-12425"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Local Privilege Escalation.This issue affects BLU-IC2: through 1.19.5; BLU-IC4: through 1.19.5 . Azure Access Technology BLU-IC2 and Azure Access Technology BLU-IC4 are both network access controllers from Azure Access Technology, Inc., a US-based company. \n\nBoth Azure Access Technology BLU-IC2 and Azure Access Technology BLU-IC4 contain a privilege escalation vulnerability caused by improper privilege management. An attacker could exploit this vulnerability to achieve local privilege escalation",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2025-12425"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2025-29081"
          }
        ],
        "trust": 1.44
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2025-12425",
            "trust": 1.6
          },
          {
            "db": "CNVD",
            "id": "CNVD-2025-29081",
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-29081"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-12425"
          }
        ]
      },
      "id": "VAR-202510-4200",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-29081"
          }
        ],
        "trust": 0.06
      },
      "iot_taxonomy": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "category": [
              "Network device"
            ],
            "sub_category": null,
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-29081"
          }
        ]
      },
      "last_update_date": "2025-11-23T23:41:28.132000Z",
      "patch": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/patch#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "title": "Patch for Azure Access Technology BLU-IC2 and Azure Access Technology BLU-IC4 privilege escalation vulnerabilities",
            "trust": 0.6,
            "url": "https://www.cnvd.org.cn/patchInfo/show/756746"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-29081"
          }
        ]
      },
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-269",
            "trust": 1.0
          }
        ],
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2025-12425"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 1.0,
            "url": "https://azure-access.com/security-advisories"
          },
          {
            "trust": 0.6,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2025-12425"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-29081"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-12425"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-29081"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-12425"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2025-11-20T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2025-29081"
          },
          {
            "date": "2025-10-28T19:15:41.540000",
            "db": "NVD",
            "id": "CVE-2025-12425"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2025-11-20T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2025-29081"
          },
          {
            "date": "2025-11-07T14:41:22.743000",
            "db": "NVD",
            "id": "CVE-2025-12425"
          }
        ]
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Azure Access Technology BLU-IC2 and Azure Access Technology BLU-IC4 privilege escalation vulnerabilities",
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-29081"
          }
        ],
        "trust": 0.6
      }
    }

    VAR-202510-4199

    Vulnerability from variot - Updated: 2025-11-23 23:39

    Systemic Lack of Cross-Site Request Forgery (CSRF) Token Implementation.This issue affects BLU-IC2: through 1.19.5; BLU-IC4: through 1.19.5 . Azure Access Technology BLU-IC2 and Azure Access Technology BLU-IC4 are both network access controllers from Azure Access Technology, Inc., a US-based company.

    Both Azure Access Technology BLU-IC2 and Azure Access Technology BLU-IC4 contain a cross-site request forgery (XPS) vulnerability caused by improper validation of user-provided input. An attacker could exploit this vulnerability to perform unauthorized actions by sending malformed HTTP requests

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-202510-4199",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "blu-ic2",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "azure access",
            "version": "1.20"
          },
          {
            "model": "blu-ic4",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "azure access",
            "version": "1.20"
          },
          {
            "model": "access technology blu-ic2",
            "scope": "lte",
            "trust": 0.6,
            "vendor": "azure",
            "version": "\u003c=1.19.5"
          },
          {
            "model": "access technology blu-ic4",
            "scope": "lte",
            "trust": 0.6,
            "vendor": "azure",
            "version": "\u003c=1.19.5"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-29080"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-12479"
          }
        ]
      },
      "cve": "CVE-2025-12479",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "CNVD",
                "availabilityImpact": "COMPLETE",
                "baseScore": 10.0,
                "confidentialityImpact": "COMPLETE",
                "exploitabilityScore": 10.0,
                "id": "CNVD-2025-29080",
                "impactScore": 10.0,
                "integrityImpact": "COMPLETE",
                "severity": "HIGH",
                "trust": 0.6,
                "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "nvd@nist.gov",
                "availabilityImpact": "HIGH",
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 2.8,
                "id": "CVE-2025-12479",
                "impactScore": 5.9,
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "trust": 1.0,
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
                "version": "3.1"
              }
            ],
            "severity": [
              {
                "author": "nvd@nist.gov",
                "id": "CVE-2025-12479",
                "trust": 1.0,
                "value": "HIGH"
              },
              {
                "author": "a0340c66-c385-4f8b-991b-3d05f6fd5220",
                "id": "CVE-2025-12479",
                "trust": 1.0,
                "value": "Critical"
              },
              {
                "author": "CNVD",
                "id": "CNVD-2025-29080",
                "trust": 0.6,
                "value": "HIGH"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-29080"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-12479"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-12479"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Systemic Lack of Cross-Site Request Forgery (CSRF) Token Implementation.This issue affects BLU-IC2: through 1.19.5; BLU-IC4: through 1.19.5 . Azure Access Technology BLU-IC2 and Azure Access Technology BLU-IC4 are both network access controllers from Azure Access Technology, Inc., a US-based company. \n\nBoth Azure Access Technology BLU-IC2 and Azure Access Technology BLU-IC4 contain a cross-site request forgery (XPS) vulnerability caused by improper validation of user-provided input. An attacker could exploit this vulnerability to perform unauthorized actions by sending malformed HTTP requests",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2025-12479"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2025-29080"
          }
        ],
        "trust": 1.44
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2025-12479",
            "trust": 1.6
          },
          {
            "db": "CNVD",
            "id": "CNVD-2025-29080",
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-29080"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-12479"
          }
        ]
      },
      "id": "VAR-202510-4199",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-29080"
          }
        ],
        "trust": 0.06
      },
      "iot_taxonomy": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "category": [
              "Network device"
            ],
            "sub_category": null,
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-29080"
          }
        ]
      },
      "last_update_date": "2025-11-23T23:39:42.791000Z",
      "patch": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/patch#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "title": "Patch for Azure Access Technology BLU-IC2 and Azure Access Technology BLU-IC4 Cross-Site Request Forgery Vulnerabilities",
            "trust": 0.6,
            "url": "https://www.cnvd.org.cn/patchInfo/show/756741"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-29080"
          }
        ]
      },
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-352",
            "trust": 1.0
          }
        ],
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2025-12479"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 1.0,
            "url": "https://azure-access.com/security-advisories"
          },
          {
            "trust": 0.6,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2025-12479"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-29080"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-12479"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-29080"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-12479"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2025-11-20T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2025-29080"
          },
          {
            "date": "2025-10-29T17:15:35.293000",
            "db": "NVD",
            "id": "CVE-2025-12479"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2025-11-20T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2025-29080"
          },
          {
            "date": "2025-11-07T13:45:44.610000",
            "db": "NVD",
            "id": "CVE-2025-12479"
          }
        ]
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Azure Access Technology BLU-IC2 and Azure Access Technology BLU-IC4 Cross-Site Request Forgery Vulnerabilities",
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-29080"
          }
        ],
        "trust": 0.6
      }
    }

    VAR-202510-3393

    Vulnerability from variot - Updated: 2025-11-23 23:37

    Undocumented administrative accounts were getting created to facilitate access for applications running on board.This issue affects BLU-IC2: through 1.19.5; BLU-IC4: through 1.19.5. Azure Access Technology BLU-IC2 and Azure Access Technology BLU-IC4 are both network access controllers from Azure Access Technology, Inc., a US-based company. Attackers could exploit this vulnerability to gain unauthorized access

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-202510-3393",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "blu-ic2",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "azure access",
            "version": "1.20"
          },
          {
            "model": "blu-ic4",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "azure access",
            "version": "1.20"
          },
          {
            "model": "access technology blu-ic2",
            "scope": "lte",
            "trust": 0.6,
            "vendor": "azure",
            "version": "\u003c=1.19.5"
          },
          {
            "model": "access technology blu-ic4",
            "scope": "lte",
            "trust": 0.6,
            "vendor": "azure",
            "version": "\u003c=1.19.5"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-29088"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-12176"
          }
        ]
      },
      "cve": "CVE-2025-12176",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "CNVD",
                "availabilityImpact": "COMPLETE",
                "baseScore": 10.0,
                "confidentialityImpact": "COMPLETE",
                "exploitabilityScore": 10.0,
                "id": "CNVD-2025-29088",
                "impactScore": 10.0,
                "integrityImpact": "COMPLETE",
                "severity": "HIGH",
                "trust": 0.6,
                "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "nvd@nist.gov",
                "availabilityImpact": "HIGH",
                "baseScore": 9.8,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 3.9,
                "id": "CVE-2025-12176",
                "impactScore": 5.9,
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "trust": 1.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              }
            ],
            "severity": [
              {
                "author": "nvd@nist.gov",
                "id": "CVE-2025-12176",
                "trust": 1.0,
                "value": "CRITICAL"
              },
              {
                "author": "a0340c66-c385-4f8b-991b-3d05f6fd5220",
                "id": "CVE-2025-12176",
                "trust": 1.0,
                "value": "Critical"
              },
              {
                "author": "CNVD",
                "id": "CNVD-2025-29088",
                "trust": 0.6,
                "value": "HIGH"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-29088"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-12176"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-12176"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Undocumented administrative accounts were getting created to facilitate access for applications running on board.This issue affects BLU-IC2: through 1.19.5; BLU-IC4: through 1.19.5. Azure Access Technology BLU-IC2 and Azure Access Technology BLU-IC4 are both network access controllers from Azure Access Technology, Inc., a US-based company. Attackers could exploit this vulnerability to gain unauthorized access",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2025-12176"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2025-29088"
          }
        ],
        "trust": 1.44
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2025-12176",
            "trust": 1.6
          },
          {
            "db": "CNVD",
            "id": "CNVD-2025-29088",
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-29088"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-12176"
          }
        ]
      },
      "id": "VAR-202510-3393",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-29088"
          }
        ],
        "trust": 0.06
      },
      "iot_taxonomy": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "category": [
              "Network device"
            ],
            "sub_category": null,
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-29088"
          }
        ]
      },
      "last_update_date": "2025-11-23T23:37:42.038000Z",
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-1242",
            "trust": 1.0
          }
        ],
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2025-12176"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 1.0,
            "url": "https://azure-access.com/security-advisories"
          },
          {
            "trust": 0.6,
            "url": "https://access.redhat.com/security/cve/cve-2025-12176"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-29088"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-12176"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-29088"
          },
          {
            "db": "NVD",
            "id": "CVE-2025-12176"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2025-11-20T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2025-29088"
          },
          {
            "date": "2025-10-24T16:15:36.617000",
            "db": "NVD",
            "id": "CVE-2025-12176"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2025-11-20T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2025-29088"
          },
          {
            "date": "2025-11-10T15:05:15.617000",
            "db": "NVD",
            "id": "CVE-2025-12176"
          }
        ]
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "An unidentified vulnerability exists in Azure Access Technology BLU-IC2 and Azure Access Technology BLU-IC4 (CNVD-2025-29088).",
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2025-29088"
          }
        ],
        "trust": 0.6
      }
    }