    CVE-2011-4879 (GCVE-0-2011-4879)

    Vulnerability from nvd – Published: 2012-02-03 20:00 – Updated: 2024-08-07 00:16
    VLAI
    Summary
    miniweb.exe in the HMI web server in Siemens WinCC flexible 2004, 2005, 2007, and 2008 before SP3; WinCC V11 (aka TIA portal) before SP2 Update 1; the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime does not properly handle URIs beginning with a 0xfa character, which allows remote attackers to read data from arbitrary memory locations or cause a denial of service (application crash) via a crafted POST request.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Assigner
    Date Public
    2011-12-02 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-07T00:16:35.211Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "http://www.us-cert.gov/control_systems/pdf/ICS-ALERT-11-332-02.pdf"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "http://www.us-cert.gov/control_systems/pdf/ICS-ALERT-11-332-02A.pdf"
              },
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-345442.pdf"
              },
              {
                "name": "18166",
                "tags": [
                  "exploit",
                  "x_refsource_EXPLOIT-DB",
                  "x_transferred"
                ],
                "url": "http://www.exploit-db.com/exploits/18166"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "http://aluigi.org/adv/winccflex_1-adv.txt"
              },
              {
                "name": "77384",
                "tags": [
                  "vdb-entry",
                  "x_refsource_OSVDB",
                  "x_transferred"
                ],
                "url": "http://www.osvdb.org/77384"
              },
              {
                "name": "simatic-miniweb-dos(71453)",
                "tags": [
                  "vdb-entry",
                  "x_refsource_XF",
                  "x_transferred"
                ],
                "url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/71453"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-030-01.pdf"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "datePublic": "2011-12-02T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "miniweb.exe in the HMI web server in Siemens WinCC flexible 2004, 2005, 2007, and 2008 before SP3; WinCC V11 (aka TIA portal) before SP2 Update 1; the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime does not properly handle URIs beginning with a 0xfa character, which allows remote attackers to read data from arbitrary memory locations or cause a denial of service (application crash) via a crafted POST request."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2017-08-28T12:57:01.000Z",
            "orgId": "37e5125f-f79b-445b-8fad-9564f167944b",
            "shortName": "certcc"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "http://www.us-cert.gov/control_systems/pdf/ICS-ALERT-11-332-02.pdf"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "http://www.us-cert.gov/control_systems/pdf/ICS-ALERT-11-332-02A.pdf"
            },
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-345442.pdf"
            },
            {
              "name": "18166",
              "tags": [
                "exploit",
                "x_refsource_EXPLOIT-DB"
              ],
              "url": "http://www.exploit-db.com/exploits/18166"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "http://aluigi.org/adv/winccflex_1-adv.txt"
            },
            {
              "name": "77384",
              "tags": [
                "vdb-entry",
                "x_refsource_OSVDB"
              ],
              "url": "http://www.osvdb.org/77384"
            },
            {
              "name": "simatic-miniweb-dos(71453)",
              "tags": [
                "vdb-entry",
                "x_refsource_XF"
              ],
              "url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/71453"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-030-01.pdf"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cert@cert.org",
              "ID": "CVE-2011-4879",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "miniweb.exe in the HMI web server in Siemens WinCC flexible 2004, 2005, 2007, and 2008 before SP3; WinCC V11 (aka TIA portal) before SP2 Update 1; the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime does not properly handle URIs beginning with a 0xfa character, which allows remote attackers to read data from arbitrary memory locations or cause a denial of service (application crash) via a crafted POST request."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "http://www.us-cert.gov/control_systems/pdf/ICS-ALERT-11-332-02.pdf",
                  "refsource": "MISC",
                  "url": "http://www.us-cert.gov/control_systems/pdf/ICS-ALERT-11-332-02.pdf"
                },
                {
                  "name": "http://www.us-cert.gov/control_systems/pdf/ICS-ALERT-11-332-02A.pdf",
                  "refsource": "MISC",
                  "url": "http://www.us-cert.gov/control_systems/pdf/ICS-ALERT-11-332-02A.pdf"
                },
                {
                  "name": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-345442.pdf",
                  "refsource": "CONFIRM",
                  "url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-345442.pdf"
                },
                {
                  "name": "18166",
                  "refsource": "EXPLOIT-DB",
                  "url": "http://www.exploit-db.com/exploits/18166"
                },
                {
                  "name": "http://aluigi.org/adv/winccflex_1-adv.txt",
                  "refsource": "MISC",
                  "url": "http://aluigi.org/adv/winccflex_1-adv.txt"
                },
                {
                  "name": "77384",
                  "refsource": "OSVDB",
                  "url": "http://www.osvdb.org/77384"
                },
                {
                  "name": "simatic-miniweb-dos(71453)",
                  "refsource": "XF",
                  "url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/71453"
                },
                {
                  "name": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-030-01.pdf",
                  "refsource": "MISC",
                  "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-030-01.pdf"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "37e5125f-f79b-445b-8fad-9564f167944b",
        "assignerShortName": "certcc",
        "cveId": "CVE-2011-4879",
        "datePublished": "2012-02-03T20:00:00.000Z",
        "dateReserved": "2011-12-21T00:00:00.000Z",
        "dateUpdated": "2024-08-07T00:16:35.211Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2011-4878 (GCVE-0-2011-4878)

    Vulnerability from nvd – Published: 2012-02-03 20:00 – Updated: 2024-08-07 00:16
    VLAI
    Summary
    Directory traversal vulnerability in miniweb.exe in the HMI web server in Siemens WinCC flexible 2004, 2005, 2007, and 2008 before SP3; WinCC V11 (aka TIA portal) before SP2 Update 1; the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime allows remote attackers to read arbitrary files via a ..%5c (dot dot backslash) in a URI.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Assigner
    Date Public
    2011-12-02 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-07T00:16:35.129Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "http://www.us-cert.gov/control_systems/pdf/ICS-ALERT-11-332-02.pdf"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "http://www.us-cert.gov/control_systems/pdf/ICS-ALERT-11-332-02A.pdf"
              },
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-345442.pdf"
              },
              {
                "name": "18166",
                "tags": [
                  "exploit",
                  "x_refsource_EXPLOIT-DB",
                  "x_transferred"
                ],
                "url": "http://www.exploit-db.com/exploits/18166"
              },
              {
                "name": "simatic-miniweb-directory-traversal(71452)",
                "tags": [
                  "vdb-entry",
                  "x_refsource_XF",
                  "x_transferred"
                ],
                "url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/71452"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "http://aluigi.org/adv/winccflex_1-adv.txt"
              },
              {
                "name": "77383",
                "tags": [
                  "vdb-entry",
                  "x_refsource_OSVDB",
                  "x_transferred"
                ],
                "url": "http://www.osvdb.org/77383"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-030-01.pdf"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "datePublic": "2011-12-02T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "Directory traversal vulnerability in miniweb.exe in the HMI web server in Siemens WinCC flexible 2004, 2005, 2007, and 2008 before SP3; WinCC V11 (aka TIA portal) before SP2 Update 1; the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime allows remote attackers to read arbitrary files via a ..%5c (dot dot backslash) in a URI."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2017-08-28T12:57:01.000Z",
            "orgId": "37e5125f-f79b-445b-8fad-9564f167944b",
            "shortName": "certcc"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "http://www.us-cert.gov/control_systems/pdf/ICS-ALERT-11-332-02.pdf"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "http://www.us-cert.gov/control_systems/pdf/ICS-ALERT-11-332-02A.pdf"
            },
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-345442.pdf"
            },
            {
              "name": "18166",
              "tags": [
                "exploit",
                "x_refsource_EXPLOIT-DB"
              ],
              "url": "http://www.exploit-db.com/exploits/18166"
            },
            {
              "name": "simatic-miniweb-directory-traversal(71452)",
              "tags": [
                "vdb-entry",
                "x_refsource_XF"
              ],
              "url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/71452"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "http://aluigi.org/adv/winccflex_1-adv.txt"
            },
            {
              "name": "77383",
              "tags": [
                "vdb-entry",
                "x_refsource_OSVDB"
              ],
              "url": "http://www.osvdb.org/77383"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-030-01.pdf"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cert@cert.org",
              "ID": "CVE-2011-4878",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Directory traversal vulnerability in miniweb.exe in the HMI web server in Siemens WinCC flexible 2004, 2005, 2007, and 2008 before SP3; WinCC V11 (aka TIA portal) before SP2 Update 1; the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime allows remote attackers to read arbitrary files via a ..%5c (dot dot backslash) in a URI."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "http://www.us-cert.gov/control_systems/pdf/ICS-ALERT-11-332-02.pdf",
                  "refsource": "MISC",
                  "url": "http://www.us-cert.gov/control_systems/pdf/ICS-ALERT-11-332-02.pdf"
                },
                {
                  "name": "http://www.us-cert.gov/control_systems/pdf/ICS-ALERT-11-332-02A.pdf",
                  "refsource": "MISC",
                  "url": "http://www.us-cert.gov/control_systems/pdf/ICS-ALERT-11-332-02A.pdf"
                },
                {
                  "name": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-345442.pdf",
                  "refsource": "CONFIRM",
                  "url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-345442.pdf"
                },
                {
                  "name": "18166",
                  "refsource": "EXPLOIT-DB",
                  "url": "http://www.exploit-db.com/exploits/18166"
                },
                {
                  "name": "simatic-miniweb-directory-traversal(71452)",
                  "refsource": "XF",
                  "url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/71452"
                },
                {
                  "name": "http://aluigi.org/adv/winccflex_1-adv.txt",
                  "refsource": "MISC",
                  "url": "http://aluigi.org/adv/winccflex_1-adv.txt"
                },
                {
                  "name": "77383",
                  "refsource": "OSVDB",
                  "url": "http://www.osvdb.org/77383"
                },
                {
                  "name": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-030-01.pdf",
                  "refsource": "MISC",
                  "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-030-01.pdf"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "37e5125f-f79b-445b-8fad-9564f167944b",
        "assignerShortName": "certcc",
        "cveId": "CVE-2011-4878",
        "datePublished": "2012-02-03T20:00:00.000Z",
        "dateReserved": "2011-12-21T00:00:00.000Z",
        "dateUpdated": "2024-08-07T00:16:35.129Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2011-4877 (GCVE-0-2011-4877)

    Vulnerability from nvd – Published: 2012-02-03 20:00 – Updated: 2024-08-07 00:16
    VLAI
    Summary
    HmiLoad in the runtime loader in Siemens WinCC flexible 2004, 2005, 2007, and 2008; WinCC V11 (aka TIA portal); the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime, when Transfer Mode is enabled, allows remote attackers to cause a denial of service (application crash) by sending crafted data over TCP.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Assigner
    Date Public
    2011-12-02 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-07T00:16:35.178Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "http://www.us-cert.gov/control_systems/pdf/ICS-ALERT-11-332-02.pdf"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "http://www.us-cert.gov/control_systems/pdf/ICS-ALERT-11-332-02A.pdf"
              },
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-345442.pdf"
              },
              {
                "name": "18166",
                "tags": [
                  "exploit",
                  "x_refsource_EXPLOIT-DB",
                  "x_transferred"
                ],
                "url": "http://www.exploit-db.com/exploits/18166"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "http://aluigi.org/adv/winccflex_1-adv.txt"
              },
              {
                "name": "simatic-hmiload-dos(71451)",
                "tags": [
                  "vdb-entry",
                  "x_refsource_XF",
                  "x_transferred"
                ],
                "url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/71451"
              },
              {
                "name": "77382",
                "tags": [
                  "vdb-entry",
                  "x_refsource_OSVDB",
                  "x_transferred"
                ],
                "url": "http://www.osvdb.org/77382"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-030-01.pdf"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "datePublic": "2011-12-02T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "HmiLoad in the runtime loader in Siemens WinCC flexible 2004, 2005, 2007, and 2008; WinCC V11 (aka TIA portal); the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime, when Transfer Mode is enabled, allows remote attackers to cause a denial of service (application crash) by sending crafted data over TCP."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2017-08-28T12:57:01.000Z",
            "orgId": "37e5125f-f79b-445b-8fad-9564f167944b",
            "shortName": "certcc"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "http://www.us-cert.gov/control_systems/pdf/ICS-ALERT-11-332-02.pdf"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "http://www.us-cert.gov/control_systems/pdf/ICS-ALERT-11-332-02A.pdf"
            },
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-345442.pdf"
            },
            {
              "name": "18166",
              "tags": [
                "exploit",
                "x_refsource_EXPLOIT-DB"
              ],
              "url": "http://www.exploit-db.com/exploits/18166"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "http://aluigi.org/adv/winccflex_1-adv.txt"
            },
            {
              "name": "simatic-hmiload-dos(71451)",
              "tags": [
                "vdb-entry",
                "x_refsource_XF"
              ],
              "url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/71451"
            },
            {
              "name": "77382",
              "tags": [
                "vdb-entry",
                "x_refsource_OSVDB"
              ],
              "url": "http://www.osvdb.org/77382"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-030-01.pdf"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cert@cert.org",
              "ID": "CVE-2011-4877",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "HmiLoad in the runtime loader in Siemens WinCC flexible 2004, 2005, 2007, and 2008; WinCC V11 (aka TIA portal); the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime, when Transfer Mode is enabled, allows remote attackers to cause a denial of service (application crash) by sending crafted data over TCP."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "http://www.us-cert.gov/control_systems/pdf/ICS-ALERT-11-332-02.pdf",
                  "refsource": "MISC",
                  "url": "http://www.us-cert.gov/control_systems/pdf/ICS-ALERT-11-332-02.pdf"
                },
                {
                  "name": "http://www.us-cert.gov/control_systems/pdf/ICS-ALERT-11-332-02A.pdf",
                  "refsource": "MISC",
                  "url": "http://www.us-cert.gov/control_systems/pdf/ICS-ALERT-11-332-02A.pdf"
                },
                {
                  "name": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-345442.pdf",
                  "refsource": "CONFIRM",
                  "url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-345442.pdf"
                },
                {
                  "name": "18166",
                  "refsource": "EXPLOIT-DB",
                  "url": "http://www.exploit-db.com/exploits/18166"
                },
                {
                  "name": "http://aluigi.org/adv/winccflex_1-adv.txt",
                  "refsource": "MISC",
                  "url": "http://aluigi.org/adv/winccflex_1-adv.txt"
                },
                {
                  "name": "simatic-hmiload-dos(71451)",
                  "refsource": "XF",
                  "url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/71451"
                },
                {
                  "name": "77382",
                  "refsource": "OSVDB",
                  "url": "http://www.osvdb.org/77382"
                },
                {
                  "name": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-030-01.pdf",
                  "refsource": "MISC",
                  "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-030-01.pdf"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "37e5125f-f79b-445b-8fad-9564f167944b",
        "assignerShortName": "certcc",
        "cveId": "CVE-2011-4877",
        "datePublished": "2012-02-03T20:00:00.000Z",
        "dateReserved": "2011-12-21T00:00:00.000Z",
        "dateUpdated": "2024-08-07T00:16:35.178Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2011-4876 (GCVE-0-2011-4876)

    Vulnerability from nvd – Published: 2012-02-03 20:00 – Updated: 2024-08-07 00:16
    VLAI
    Summary
    Directory traversal vulnerability in HmiLoad in the runtime loader in Siemens WinCC flexible 2004, 2005, 2007, and 2008; WinCC V11 (aka TIA portal); the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime, when Transfer Mode is enabled, allows remote attackers to execute, read, create, modify, or delete arbitrary files via a .. (dot dot) in a string.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Assigner
    Date Public
    2011-12-02 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-07T00:16:35.056Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "name": "46997",
                "tags": [
                  "third-party-advisory",
                  "x_refsource_SECUNIA",
                  "x_transferred"
                ],
                "url": "http://secunia.com/advisories/46997"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "http://www.us-cert.gov/control_systems/pdf/ICS-ALERT-11-332-02.pdf"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "http://www.us-cert.gov/control_systems/pdf/ICS-ALERT-11-332-02A.pdf"
              },
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-345442.pdf"
              },
              {
                "name": "18166",
                "tags": [
                  "exploit",
                  "x_refsource_EXPLOIT-DB",
                  "x_transferred"
                ],
                "url": "http://www.exploit-db.com/exploits/18166"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "http://aluigi.org/adv/winccflex_1-adv.txt"
              },
              {
                "name": "simatic-hmiload-dir-traversal(71450)",
                "tags": [
                  "vdb-entry",
                  "x_refsource_XF",
                  "x_transferred"
                ],
                "url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/71450"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-030-01.pdf"
              },
              {
                "name": "77381",
                "tags": [
                  "vdb-entry",
                  "x_refsource_OSVDB",
                  "x_transferred"
                ],
                "url": "http://www.osvdb.org/77381"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "datePublic": "2011-12-02T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "Directory traversal vulnerability in HmiLoad in the runtime loader in Siemens WinCC flexible 2004, 2005, 2007, and 2008; WinCC V11 (aka TIA portal); the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime, when Transfer Mode is enabled, allows remote attackers to execute, read, create, modify, or delete arbitrary files via a .. (dot dot) in a string."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2017-08-28T12:57:01.000Z",
            "orgId": "37e5125f-f79b-445b-8fad-9564f167944b",
            "shortName": "certcc"
          },
          "references": [
            {
              "name": "46997",
              "tags": [
                "third-party-advisory",
                "x_refsource_SECUNIA"
              ],
              "url": "http://secunia.com/advisories/46997"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "http://www.us-cert.gov/control_systems/pdf/ICS-ALERT-11-332-02.pdf"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "http://www.us-cert.gov/control_systems/pdf/ICS-ALERT-11-332-02A.pdf"
            },
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-345442.pdf"
            },
            {
              "name": "18166",
              "tags": [
                "exploit",
                "x_refsource_EXPLOIT-DB"
              ],
              "url": "http://www.exploit-db.com/exploits/18166"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "http://aluigi.org/adv/winccflex_1-adv.txt"
            },
            {
              "name": "simatic-hmiload-dir-traversal(71450)",
              "tags": [
                "vdb-entry",
                "x_refsource_XF"
              ],
              "url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/71450"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-030-01.pdf"
            },
            {
              "name": "77381",
              "tags": [
                "vdb-entry",
                "x_refsource_OSVDB"
              ],
              "url": "http://www.osvdb.org/77381"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cert@cert.org",
              "ID": "CVE-2011-4876",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Directory traversal vulnerability in HmiLoad in the runtime loader in Siemens WinCC flexible 2004, 2005, 2007, and 2008; WinCC V11 (aka TIA portal); the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime, when Transfer Mode is enabled, allows remote attackers to execute, read, create, modify, or delete arbitrary files via a .. (dot dot) in a string."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "46997",
                  "refsource": "SECUNIA",
                  "url": "http://secunia.com/advisories/46997"
                },
                {
                  "name": "http://www.us-cert.gov/control_systems/pdf/ICS-ALERT-11-332-02.pdf",
                  "refsource": "MISC",
                  "url": "http://www.us-cert.gov/control_systems/pdf/ICS-ALERT-11-332-02.pdf"
                },
                {
                  "name": "http://www.us-cert.gov/control_systems/pdf/ICS-ALERT-11-332-02A.pdf",
                  "refsource": "MISC",
                  "url": "http://www.us-cert.gov/control_systems/pdf/ICS-ALERT-11-332-02A.pdf"
                },
                {
                  "name": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-345442.pdf",
                  "refsource": "CONFIRM",
                  "url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-345442.pdf"
                },
                {
                  "name": "18166",
                  "refsource": "EXPLOIT-DB",
                  "url": "http://www.exploit-db.com/exploits/18166"
                },
                {
                  "name": "http://aluigi.org/adv/winccflex_1-adv.txt",
                  "refsource": "MISC",
                  "url": "http://aluigi.org/adv/winccflex_1-adv.txt"
                },
                {
                  "name": "simatic-hmiload-dir-traversal(71450)",
                  "refsource": "XF",
                  "url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/71450"
                },
                {
                  "name": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-030-01.pdf",
                  "refsource": "MISC",
                  "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-030-01.pdf"
                },
                {
                  "name": "77381",
                  "refsource": "OSVDB",
                  "url": "http://www.osvdb.org/77381"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "37e5125f-f79b-445b-8fad-9564f167944b",
        "assignerShortName": "certcc",
        "cveId": "CVE-2011-4876",
        "datePublished": "2012-02-03T20:00:00.000Z",
        "dateReserved": "2011-12-21T00:00:00.000Z",
        "dateUpdated": "2024-08-07T00:16:35.056Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2011-4875 (GCVE-0-2011-4875)

    Vulnerability from nvd – Published: 2012-02-03 20:00 – Updated: 2024-08-07 00:16
    VLAI
    Summary
    Stack-based buffer overflow in HmiLoad in the runtime loader in Siemens WinCC flexible 2004, 2005, 2007, and 2008; WinCC V11 (aka TIA portal); the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime, when Transfer Mode is enabled, allows remote attackers to execute arbitrary code via vectors related to Unicode strings.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Assigner
    Date Public
    2011-12-02 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-07T00:16:35.128Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "http://www.us-cert.gov/control_systems/pdf/ICS-ALERT-11-332-02.pdf"
              },
              {
                "name": "77380",
                "tags": [
                  "vdb-entry",
                  "x_refsource_OSVDB",
                  "x_transferred"
                ],
                "url": "http://www.osvdb.org/77380"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "http://www.us-cert.gov/control_systems/pdf/ICS-ALERT-11-332-02A.pdf"
              },
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-345442.pdf"
              },
              {
                "name": "18166",
                "tags": [
                  "exploit",
                  "x_refsource_EXPLOIT-DB",
                  "x_transferred"
                ],
                "url": "http://www.exploit-db.com/exploits/18166"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "http://aluigi.org/adv/winccflex_1-adv.txt"
              },
              {
                "name": "simatic-hmiload-bo(71449)",
                "tags": [
                  "vdb-entry",
                  "x_refsource_XF",
                  "x_transferred"
                ],
                "url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/71449"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-030-01.pdf"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "datePublic": "2011-12-02T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "Stack-based buffer overflow in HmiLoad in the runtime loader in Siemens WinCC flexible 2004, 2005, 2007, and 2008; WinCC V11 (aka TIA portal); the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime, when Transfer Mode is enabled, allows remote attackers to execute arbitrary code via vectors related to Unicode strings."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2017-08-28T12:57:01.000Z",
            "orgId": "37e5125f-f79b-445b-8fad-9564f167944b",
            "shortName": "certcc"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "http://www.us-cert.gov/control_systems/pdf/ICS-ALERT-11-332-02.pdf"
            },
            {
              "name": "77380",
              "tags": [
                "vdb-entry",
                "x_refsource_OSVDB"
              ],
              "url": "http://www.osvdb.org/77380"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "http://www.us-cert.gov/control_systems/pdf/ICS-ALERT-11-332-02A.pdf"
            },
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-345442.pdf"
            },
            {
              "name": "18166",
              "tags": [
                "exploit",
                "x_refsource_EXPLOIT-DB"
              ],
              "url": "http://www.exploit-db.com/exploits/18166"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "http://aluigi.org/adv/winccflex_1-adv.txt"
            },
            {
              "name": "simatic-hmiload-bo(71449)",
              "tags": [
                "vdb-entry",
                "x_refsource_XF"
              ],
              "url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/71449"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-030-01.pdf"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cert@cert.org",
              "ID": "CVE-2011-4875",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Stack-based buffer overflow in HmiLoad in the runtime loader in Siemens WinCC flexible 2004, 2005, 2007, and 2008; WinCC V11 (aka TIA portal); the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime, when Transfer Mode is enabled, allows remote attackers to execute arbitrary code via vectors related to Unicode strings."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "http://www.us-cert.gov/control_systems/pdf/ICS-ALERT-11-332-02.pdf",
                  "refsource": "MISC",
                  "url": "http://www.us-cert.gov/control_systems/pdf/ICS-ALERT-11-332-02.pdf"
                },
                {
                  "name": "77380",
                  "refsource": "OSVDB",
                  "url": "http://www.osvdb.org/77380"
                },
                {
                  "name": "http://www.us-cert.gov/control_systems/pdf/ICS-ALERT-11-332-02A.pdf",
                  "refsource": "MISC",
                  "url": "http://www.us-cert.gov/control_systems/pdf/ICS-ALERT-11-332-02A.pdf"
                },
                {
                  "name": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-345442.pdf",
                  "refsource": "CONFIRM",
                  "url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-345442.pdf"
                },
                {
                  "name": "18166",
                  "refsource": "EXPLOIT-DB",
                  "url": "http://www.exploit-db.com/exploits/18166"
                },
                {
                  "name": "http://aluigi.org/adv/winccflex_1-adv.txt",
                  "refsource": "MISC",
                  "url": "http://aluigi.org/adv/winccflex_1-adv.txt"
                },
                {
                  "name": "simatic-hmiload-bo(71449)",
                  "refsource": "XF",
                  "url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/71449"
                },
                {
                  "name": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-030-01.pdf",
                  "refsource": "MISC",
                  "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-030-01.pdf"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "37e5125f-f79b-445b-8fad-9564f167944b",
        "assignerShortName": "certcc",
        "cveId": "CVE-2011-4875",
        "datePublished": "2012-02-03T20:00:00.000Z",
        "dateReserved": "2011-12-21T00:00:00.000Z",
        "dateUpdated": "2024-08-07T00:16:35.128Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2011-4514 (GCVE-0-2011-4514)

    Vulnerability from nvd – Published: 2012-02-03 20:00 – Updated: 2024-09-17 03:27
    VLAI
    Summary
    The TELNET daemon in Siemens WinCC flexible 2004, 2005, 2007, and 2008; WinCC V11 (aka TIA portal); the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime does not perform authentication, which makes it easier for remote attackers to obtain access via a TCP session.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Assigner
    References
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-07T00:09:18.497Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-345442.pdf"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-030-01.pdf"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "The TELNET daemon in Siemens WinCC flexible 2004, 2005, 2007, and 2008; WinCC V11 (aka TIA portal); the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime does not perform authentication, which makes it easier for remote attackers to obtain access via a TCP session."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2012-02-03T20:00:00.000Z",
            "orgId": "37e5125f-f79b-445b-8fad-9564f167944b",
            "shortName": "certcc"
          },
          "references": [
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-345442.pdf"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-030-01.pdf"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cert@cert.org",
              "ID": "CVE-2011-4514",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "The TELNET daemon in Siemens WinCC flexible 2004, 2005, 2007, and 2008; WinCC V11 (aka TIA portal); the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime does not perform authentication, which makes it easier for remote attackers to obtain access via a TCP session."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-345442.pdf",
                  "refsource": "CONFIRM",
                  "url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-345442.pdf"
                },
                {
                  "name": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-030-01.pdf",
                  "refsource": "MISC",
                  "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-030-01.pdf"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "37e5125f-f79b-445b-8fad-9564f167944b",
        "assignerShortName": "certcc",
        "cveId": "CVE-2011-4514",
        "datePublished": "2012-02-03T20:00:00.000Z",
        "dateReserved": "2011-11-22T00:00:00.000Z",
        "dateUpdated": "2024-09-17T03:27:33.362Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2011-4513 (GCVE-0-2011-4513)

    Vulnerability from nvd – Published: 2012-02-03 20:00 – Updated: 2024-09-16 22:31
    VLAI
    Summary
    Siemens WinCC flexible 2004, 2005, 2007, and 2008; WinCC V11 (aka TIA portal); the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime allow user-assisted remote attackers to execute arbitrary code via a crafted project file, related to the HMI web server and runtime loader.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Assigner
    References
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-07T00:09:18.521Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-345442.pdf"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-030-01.pdf"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Siemens WinCC flexible 2004, 2005, 2007, and 2008; WinCC V11 (aka TIA portal); the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime allow user-assisted remote attackers to execute arbitrary code via a crafted project file, related to the HMI web server and runtime loader."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2012-02-03T20:00:00.000Z",
            "orgId": "37e5125f-f79b-445b-8fad-9564f167944b",
            "shortName": "certcc"
          },
          "references": [
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-345442.pdf"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-030-01.pdf"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cert@cert.org",
              "ID": "CVE-2011-4513",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Siemens WinCC flexible 2004, 2005, 2007, and 2008; WinCC V11 (aka TIA portal); the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime allow user-assisted remote attackers to execute arbitrary code via a crafted project file, related to the HMI web server and runtime loader."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-345442.pdf",
                  "refsource": "CONFIRM",
                  "url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-345442.pdf"
                },
                {
                  "name": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-030-01.pdf",
                  "refsource": "MISC",
                  "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-030-01.pdf"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "37e5125f-f79b-445b-8fad-9564f167944b",
        "assignerShortName": "certcc",
        "cveId": "CVE-2011-4513",
        "datePublished": "2012-02-03T20:00:00.000Z",
        "dateReserved": "2011-11-22T00:00:00.000Z",
        "dateUpdated": "2024-09-16T22:31:15.150Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2011-4512 (GCVE-0-2011-4512)

    Vulnerability from nvd – Published: 2012-02-03 20:00 – Updated: 2024-09-16 18:09
    VLAI
    Summary
    CRLF injection vulnerability in the HMI web server in Siemens WinCC flexible 2004, 2005, 2007, and 2008 before SP3; WinCC V11 (aka TIA portal) before SP2 Update 1; the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime allows remote attackers to inject arbitrary HTTP headers and conduct HTTP response splitting attacks via unspecified vectors.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Assigner
    References
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-07T00:09:18.437Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-345442.pdf"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-030-01.pdf"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "CRLF injection vulnerability in the HMI web server in Siemens WinCC flexible 2004, 2005, 2007, and 2008 before SP3; WinCC V11 (aka TIA portal) before SP2 Update 1; the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime allows remote attackers to inject arbitrary HTTP headers and conduct HTTP response splitting attacks via unspecified vectors."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2012-02-03T20:00:00.000Z",
            "orgId": "37e5125f-f79b-445b-8fad-9564f167944b",
            "shortName": "certcc"
          },
          "references": [
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-345442.pdf"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-030-01.pdf"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cert@cert.org",
              "ID": "CVE-2011-4512",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "CRLF injection vulnerability in the HMI web server in Siemens WinCC flexible 2004, 2005, 2007, and 2008 before SP3; WinCC V11 (aka TIA portal) before SP2 Update 1; the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime allows remote attackers to inject arbitrary HTTP headers and conduct HTTP response splitting attacks via unspecified vectors."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-345442.pdf",
                  "refsource": "CONFIRM",
                  "url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-345442.pdf"
                },
                {
                  "name": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-030-01.pdf",
                  "refsource": "MISC",
                  "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-030-01.pdf"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "37e5125f-f79b-445b-8fad-9564f167944b",
        "assignerShortName": "certcc",
        "cveId": "CVE-2011-4512",
        "datePublished": "2012-02-03T20:00:00.000Z",
        "dateReserved": "2011-11-22T00:00:00.000Z",
        "dateUpdated": "2024-09-16T18:09:01.418Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2011-4511 (GCVE-0-2011-4511)

    Vulnerability from nvd – Published: 2012-02-03 20:00 – Updated: 2024-09-16 20:07
    VLAI
    Summary
    Cross-site scripting (XSS) vulnerability in the HMI web server in Siemens WinCC flexible 2004, 2005, 2007, and 2008 before SP3; WinCC V11 (aka TIA portal) before SP2 Update 1; the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime allows remote attackers to inject arbitrary web script or HTML via unspecified vectors, a different vulnerability than CVE-2011-4510.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Assigner
    References
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-07T00:09:18.416Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-345442.pdf"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-030-01.pdf"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Cross-site scripting (XSS) vulnerability in the HMI web server in Siemens WinCC flexible 2004, 2005, 2007, and 2008 before SP3; WinCC V11 (aka TIA portal) before SP2 Update 1; the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime allows remote attackers to inject arbitrary web script or HTML via unspecified vectors, a different vulnerability than CVE-2011-4510."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2012-02-03T20:00:00.000Z",
            "orgId": "37e5125f-f79b-445b-8fad-9564f167944b",
            "shortName": "certcc"
          },
          "references": [
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-345442.pdf"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-030-01.pdf"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cert@cert.org",
              "ID": "CVE-2011-4511",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Cross-site scripting (XSS) vulnerability in the HMI web server in Siemens WinCC flexible 2004, 2005, 2007, and 2008 before SP3; WinCC V11 (aka TIA portal) before SP2 Update 1; the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime allows remote attackers to inject arbitrary web script or HTML via unspecified vectors, a different vulnerability than CVE-2011-4510."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-345442.pdf",
                  "refsource": "CONFIRM",
                  "url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-345442.pdf"
                },
                {
                  "name": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-030-01.pdf",
                  "refsource": "MISC",
                  "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-030-01.pdf"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "37e5125f-f79b-445b-8fad-9564f167944b",
        "assignerShortName": "certcc",
        "cveId": "CVE-2011-4511",
        "datePublished": "2012-02-03T20:00:00.000Z",
        "dateReserved": "2011-11-22T00:00:00.000Z",
        "dateUpdated": "2024-09-16T20:07:51.541Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2011-4510 (GCVE-0-2011-4510)

    Vulnerability from nvd – Published: 2012-02-03 20:00 – Updated: 2024-09-16 18:28
    VLAI
    Summary
    Cross-site scripting (XSS) vulnerability in the HMI web server in Siemens WinCC flexible 2004, 2005, 2007, and 2008 before SP3; WinCC V11 (aka TIA portal) before SP2 Update 1; the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime allows remote attackers to inject arbitrary web script or HTML via unspecified vectors, a different vulnerability than CVE-2011-4511.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Assigner
    References
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-07T00:09:18.439Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-345442.pdf"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-030-01.pdf"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Cross-site scripting (XSS) vulnerability in the HMI web server in Siemens WinCC flexible 2004, 2005, 2007, and 2008 before SP3; WinCC V11 (aka TIA portal) before SP2 Update 1; the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime allows remote attackers to inject arbitrary web script or HTML via unspecified vectors, a different vulnerability than CVE-2011-4511."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2012-02-03T20:00:00.000Z",
            "orgId": "37e5125f-f79b-445b-8fad-9564f167944b",
            "shortName": "certcc"
          },
          "references": [
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-345442.pdf"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-030-01.pdf"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cert@cert.org",
              "ID": "CVE-2011-4510",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Cross-site scripting (XSS) vulnerability in the HMI web server in Siemens WinCC flexible 2004, 2005, 2007, and 2008 before SP3; WinCC V11 (aka TIA portal) before SP2 Update 1; the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime allows remote attackers to inject arbitrary web script or HTML via unspecified vectors, a different vulnerability than CVE-2011-4511."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-345442.pdf",
                  "refsource": "CONFIRM",
                  "url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-345442.pdf"
                },
                {
                  "name": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-030-01.pdf",
                  "refsource": "MISC",
                  "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-030-01.pdf"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "37e5125f-f79b-445b-8fad-9564f167944b",
        "assignerShortName": "certcc",
        "cveId": "CVE-2011-4510",
        "datePublished": "2012-02-03T20:00:00.000Z",
        "dateReserved": "2011-11-22T00:00:00.000Z",
        "dateUpdated": "2024-09-16T18:28:15.216Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2011-4509 (GCVE-0-2011-4509)

    Vulnerability from nvd – Published: 2012-02-03 20:00 – Updated: 2024-09-17 01:26
    VLAI
    Summary
    The HMI web server in Siemens WinCC flexible 2004, 2005, 2007, and 2008; WinCC V11 (aka TIA portal); the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime has an improperly selected default password for the administrator account, which makes it easier for remote attackers to obtain access via a brute-force approach involving many HTTP requests.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Assigner
    References
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-07T00:09:18.472Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-345442.pdf"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-030-01.pdf"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "The HMI web server in Siemens WinCC flexible 2004, 2005, 2007, and 2008; WinCC V11 (aka TIA portal); the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime has an improperly selected default password for the administrator account, which makes it easier for remote attackers to obtain access via a brute-force approach involving many HTTP requests."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2012-02-03T20:00:00.000Z",
            "orgId": "37e5125f-f79b-445b-8fad-9564f167944b",
            "shortName": "certcc"
          },
          "references": [
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-345442.pdf"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-030-01.pdf"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cert@cert.org",
              "ID": "CVE-2011-4509",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "The HMI web server in Siemens WinCC flexible 2004, 2005, 2007, and 2008; WinCC V11 (aka TIA portal); the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime has an improperly selected default password for the administrator account, which makes it easier for remote attackers to obtain access via a brute-force approach involving many HTTP requests."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-345442.pdf",
                  "refsource": "CONFIRM",
                  "url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-345442.pdf"
                },
                {
                  "name": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-030-01.pdf",
                  "refsource": "MISC",
                  "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-030-01.pdf"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "37e5125f-f79b-445b-8fad-9564f167944b",
        "assignerShortName": "certcc",
        "cveId": "CVE-2011-4509",
        "datePublished": "2012-02-03T20:00:00.000Z",
        "dateReserved": "2011-11-22T00:00:00.000Z",
        "dateUpdated": "2024-09-17T01:26:11.252Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2011-4508 (GCVE-0-2011-4508)

    Vulnerability from nvd – Published: 2012-02-03 20:00 – Updated: 2024-09-16 20:47
    VLAI
    Summary
    The HMI web server in Siemens WinCC flexible 2004, 2005, 2007, and 2008 before SP3; WinCC V11 (aka TIA portal) before SP2 Update 1; the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime generates predictable authentication tokens for cookies, which makes it easier for remote attackers to bypass authentication via a crafted cookie.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Assigner
    References
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-07T00:09:18.474Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-345442.pdf"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-030-01.pdf"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "The HMI web server in Siemens WinCC flexible 2004, 2005, 2007, and 2008 before SP3; WinCC V11 (aka TIA portal) before SP2 Update 1; the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime generates predictable authentication tokens for cookies, which makes it easier for remote attackers to bypass authentication via a crafted cookie."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2012-02-03T20:00:00.000Z",
            "orgId": "37e5125f-f79b-445b-8fad-9564f167944b",
            "shortName": "certcc"
          },
          "references": [
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-345442.pdf"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-030-01.pdf"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cert@cert.org",
              "ID": "CVE-2011-4508",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "The HMI web server in Siemens WinCC flexible 2004, 2005, 2007, and 2008 before SP3; WinCC V11 (aka TIA portal) before SP2 Update 1; the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime generates predictable authentication tokens for cookies, which makes it easier for remote attackers to bypass authentication via a crafted cookie."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-345442.pdf",
                  "refsource": "CONFIRM",
                  "url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-345442.pdf"
                },
                {
                  "name": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-030-01.pdf",
                  "refsource": "MISC",
                  "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-030-01.pdf"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "37e5125f-f79b-445b-8fad-9564f167944b",
        "assignerShortName": "certcc",
        "cveId": "CVE-2011-4508",
        "datePublished": "2012-02-03T20:00:00.000Z",
        "dateReserved": "2011-11-22T00:00:00.000Z",
        "dateUpdated": "2024-09-16T20:47:55.183Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2011-4511 (GCVE-0-2011-4511)

    Vulnerability from cvelistv5 – Published: 2012-02-03 20:00 – Updated: 2024-09-16 20:07
    VLAI
    Summary
    Cross-site scripting (XSS) vulnerability in the HMI web server in Siemens WinCC flexible 2004, 2005, 2007, and 2008 before SP3; WinCC V11 (aka TIA portal) before SP2 Update 1; the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime allows remote attackers to inject arbitrary web script or HTML via unspecified vectors, a different vulnerability than CVE-2011-4510.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Assigner
    References
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-07T00:09:18.416Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-345442.pdf"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-030-01.pdf"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Cross-site scripting (XSS) vulnerability in the HMI web server in Siemens WinCC flexible 2004, 2005, 2007, and 2008 before SP3; WinCC V11 (aka TIA portal) before SP2 Update 1; the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime allows remote attackers to inject arbitrary web script or HTML via unspecified vectors, a different vulnerability than CVE-2011-4510."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2012-02-03T20:00:00.000Z",
            "orgId": "37e5125f-f79b-445b-8fad-9564f167944b",
            "shortName": "certcc"
          },
          "references": [
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-345442.pdf"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-030-01.pdf"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cert@cert.org",
              "ID": "CVE-2011-4511",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Cross-site scripting (XSS) vulnerability in the HMI web server in Siemens WinCC flexible 2004, 2005, 2007, and 2008 before SP3; WinCC V11 (aka TIA portal) before SP2 Update 1; the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime allows remote attackers to inject arbitrary web script or HTML via unspecified vectors, a different vulnerability than CVE-2011-4510."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-345442.pdf",
                  "refsource": "CONFIRM",
                  "url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-345442.pdf"
                },
                {
                  "name": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-030-01.pdf",
                  "refsource": "MISC",
                  "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-030-01.pdf"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "37e5125f-f79b-445b-8fad-9564f167944b",
        "assignerShortName": "certcc",
        "cveId": "CVE-2011-4511",
        "datePublished": "2012-02-03T20:00:00.000Z",
        "dateReserved": "2011-11-22T00:00:00.000Z",
        "dateUpdated": "2024-09-16T20:07:51.541Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2011-4510 (GCVE-0-2011-4510)

    Vulnerability from cvelistv5 – Published: 2012-02-03 20:00 – Updated: 2024-09-16 18:28
    VLAI
    Summary
    Cross-site scripting (XSS) vulnerability in the HMI web server in Siemens WinCC flexible 2004, 2005, 2007, and 2008 before SP3; WinCC V11 (aka TIA portal) before SP2 Update 1; the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime allows remote attackers to inject arbitrary web script or HTML via unspecified vectors, a different vulnerability than CVE-2011-4511.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Assigner
    References
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-07T00:09:18.439Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-345442.pdf"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-030-01.pdf"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Cross-site scripting (XSS) vulnerability in the HMI web server in Siemens WinCC flexible 2004, 2005, 2007, and 2008 before SP3; WinCC V11 (aka TIA portal) before SP2 Update 1; the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime allows remote attackers to inject arbitrary web script or HTML via unspecified vectors, a different vulnerability than CVE-2011-4511."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2012-02-03T20:00:00.000Z",
            "orgId": "37e5125f-f79b-445b-8fad-9564f167944b",
            "shortName": "certcc"
          },
          "references": [
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-345442.pdf"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-030-01.pdf"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cert@cert.org",
              "ID": "CVE-2011-4510",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Cross-site scripting (XSS) vulnerability in the HMI web server in Siemens WinCC flexible 2004, 2005, 2007, and 2008 before SP3; WinCC V11 (aka TIA portal) before SP2 Update 1; the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime allows remote attackers to inject arbitrary web script or HTML via unspecified vectors, a different vulnerability than CVE-2011-4511."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-345442.pdf",
                  "refsource": "CONFIRM",
                  "url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-345442.pdf"
                },
                {
                  "name": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-030-01.pdf",
                  "refsource": "MISC",
                  "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-030-01.pdf"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "37e5125f-f79b-445b-8fad-9564f167944b",
        "assignerShortName": "certcc",
        "cveId": "CVE-2011-4510",
        "datePublished": "2012-02-03T20:00:00.000Z",
        "dateReserved": "2011-11-22T00:00:00.000Z",
        "dateUpdated": "2024-09-16T18:28:15.216Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2011-4875 (GCVE-0-2011-4875)

    Vulnerability from cvelistv5 – Published: 2012-02-03 20:00 – Updated: 2024-08-07 00:16
    VLAI
    Summary
    Stack-based buffer overflow in HmiLoad in the runtime loader in Siemens WinCC flexible 2004, 2005, 2007, and 2008; WinCC V11 (aka TIA portal); the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime, when Transfer Mode is enabled, allows remote attackers to execute arbitrary code via vectors related to Unicode strings.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Assigner
    Date Public
    2011-12-02 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-07T00:16:35.128Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "http://www.us-cert.gov/control_systems/pdf/ICS-ALERT-11-332-02.pdf"
              },
              {
                "name": "77380",
                "tags": [
                  "vdb-entry",
                  "x_refsource_OSVDB",
                  "x_transferred"
                ],
                "url": "http://www.osvdb.org/77380"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "http://www.us-cert.gov/control_systems/pdf/ICS-ALERT-11-332-02A.pdf"
              },
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-345442.pdf"
              },
              {
                "name": "18166",
                "tags": [
                  "exploit",
                  "x_refsource_EXPLOIT-DB",
                  "x_transferred"
                ],
                "url": "http://www.exploit-db.com/exploits/18166"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "http://aluigi.org/adv/winccflex_1-adv.txt"
              },
              {
                "name": "simatic-hmiload-bo(71449)",
                "tags": [
                  "vdb-entry",
                  "x_refsource_XF",
                  "x_transferred"
                ],
                "url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/71449"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-030-01.pdf"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "datePublic": "2011-12-02T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "Stack-based buffer overflow in HmiLoad in the runtime loader in Siemens WinCC flexible 2004, 2005, 2007, and 2008; WinCC V11 (aka TIA portal); the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime, when Transfer Mode is enabled, allows remote attackers to execute arbitrary code via vectors related to Unicode strings."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2017-08-28T12:57:01.000Z",
            "orgId": "37e5125f-f79b-445b-8fad-9564f167944b",
            "shortName": "certcc"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "http://www.us-cert.gov/control_systems/pdf/ICS-ALERT-11-332-02.pdf"
            },
            {
              "name": "77380",
              "tags": [
                "vdb-entry",
                "x_refsource_OSVDB"
              ],
              "url": "http://www.osvdb.org/77380"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "http://www.us-cert.gov/control_systems/pdf/ICS-ALERT-11-332-02A.pdf"
            },
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-345442.pdf"
            },
            {
              "name": "18166",
              "tags": [
                "exploit",
                "x_refsource_EXPLOIT-DB"
              ],
              "url": "http://www.exploit-db.com/exploits/18166"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "http://aluigi.org/adv/winccflex_1-adv.txt"
            },
            {
              "name": "simatic-hmiload-bo(71449)",
              "tags": [
                "vdb-entry",
                "x_refsource_XF"
              ],
              "url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/71449"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-030-01.pdf"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cert@cert.org",
              "ID": "CVE-2011-4875",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Stack-based buffer overflow in HmiLoad in the runtime loader in Siemens WinCC flexible 2004, 2005, 2007, and 2008; WinCC V11 (aka TIA portal); the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime, when Transfer Mode is enabled, allows remote attackers to execute arbitrary code via vectors related to Unicode strings."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "http://www.us-cert.gov/control_systems/pdf/ICS-ALERT-11-332-02.pdf",
                  "refsource": "MISC",
                  "url": "http://www.us-cert.gov/control_systems/pdf/ICS-ALERT-11-332-02.pdf"
                },
                {
                  "name": "77380",
                  "refsource": "OSVDB",
                  "url": "http://www.osvdb.org/77380"
                },
                {
                  "name": "http://www.us-cert.gov/control_systems/pdf/ICS-ALERT-11-332-02A.pdf",
                  "refsource": "MISC",
                  "url": "http://www.us-cert.gov/control_systems/pdf/ICS-ALERT-11-332-02A.pdf"
                },
                {
                  "name": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-345442.pdf",
                  "refsource": "CONFIRM",
                  "url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-345442.pdf"
                },
                {
                  "name": "18166",
                  "refsource": "EXPLOIT-DB",
                  "url": "http://www.exploit-db.com/exploits/18166"
                },
                {
                  "name": "http://aluigi.org/adv/winccflex_1-adv.txt",
                  "refsource": "MISC",
                  "url": "http://aluigi.org/adv/winccflex_1-adv.txt"
                },
                {
                  "name": "simatic-hmiload-bo(71449)",
                  "refsource": "XF",
                  "url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/71449"
                },
                {
                  "name": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-030-01.pdf",
                  "refsource": "MISC",
                  "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-030-01.pdf"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "37e5125f-f79b-445b-8fad-9564f167944b",
        "assignerShortName": "certcc",
        "cveId": "CVE-2011-4875",
        "datePublished": "2012-02-03T20:00:00.000Z",
        "dateReserved": "2011-12-21T00:00:00.000Z",
        "dateUpdated": "2024-08-07T00:16:35.128Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2011-4508 (GCVE-0-2011-4508)

    Vulnerability from cvelistv5 – Published: 2012-02-03 20:00 – Updated: 2024-09-16 20:47
    VLAI
    Summary
    The HMI web server in Siemens WinCC flexible 2004, 2005, 2007, and 2008 before SP3; WinCC V11 (aka TIA portal) before SP2 Update 1; the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime generates predictable authentication tokens for cookies, which makes it easier for remote attackers to bypass authentication via a crafted cookie.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Assigner
    References
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-07T00:09:18.474Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-345442.pdf"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-030-01.pdf"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "The HMI web server in Siemens WinCC flexible 2004, 2005, 2007, and 2008 before SP3; WinCC V11 (aka TIA portal) before SP2 Update 1; the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime generates predictable authentication tokens for cookies, which makes it easier for remote attackers to bypass authentication via a crafted cookie."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2012-02-03T20:00:00.000Z",
            "orgId": "37e5125f-f79b-445b-8fad-9564f167944b",
            "shortName": "certcc"
          },
          "references": [
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-345442.pdf"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-030-01.pdf"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cert@cert.org",
              "ID": "CVE-2011-4508",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "The HMI web server in Siemens WinCC flexible 2004, 2005, 2007, and 2008 before SP3; WinCC V11 (aka TIA portal) before SP2 Update 1; the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime generates predictable authentication tokens for cookies, which makes it easier for remote attackers to bypass authentication via a crafted cookie."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-345442.pdf",
                  "refsource": "CONFIRM",
                  "url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-345442.pdf"
                },
                {
                  "name": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-030-01.pdf",
                  "refsource": "MISC",
                  "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-030-01.pdf"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "37e5125f-f79b-445b-8fad-9564f167944b",
        "assignerShortName": "certcc",
        "cveId": "CVE-2011-4508",
        "datePublished": "2012-02-03T20:00:00.000Z",
        "dateReserved": "2011-11-22T00:00:00.000Z",
        "dateUpdated": "2024-09-16T20:47:55.183Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2011-4877 (GCVE-0-2011-4877)

    Vulnerability from cvelistv5 – Published: 2012-02-03 20:00 – Updated: 2024-08-07 00:16
    VLAI
    Summary
    HmiLoad in the runtime loader in Siemens WinCC flexible 2004, 2005, 2007, and 2008; WinCC V11 (aka TIA portal); the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime, when Transfer Mode is enabled, allows remote attackers to cause a denial of service (application crash) by sending crafted data over TCP.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Assigner
    Date Public
    2011-12-02 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-07T00:16:35.178Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "http://www.us-cert.gov/control_systems/pdf/ICS-ALERT-11-332-02.pdf"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "http://www.us-cert.gov/control_systems/pdf/ICS-ALERT-11-332-02A.pdf"
              },
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-345442.pdf"
              },
              {
                "name": "18166",
                "tags": [
                  "exploit",
                  "x_refsource_EXPLOIT-DB",
                  "x_transferred"
                ],
                "url": "http://www.exploit-db.com/exploits/18166"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "http://aluigi.org/adv/winccflex_1-adv.txt"
              },
              {
                "name": "simatic-hmiload-dos(71451)",
                "tags": [
                  "vdb-entry",
                  "x_refsource_XF",
                  "x_transferred"
                ],
                "url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/71451"
              },
              {
                "name": "77382",
                "tags": [
                  "vdb-entry",
                  "x_refsource_OSVDB",
                  "x_transferred"
                ],
                "url": "http://www.osvdb.org/77382"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-030-01.pdf"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "datePublic": "2011-12-02T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "HmiLoad in the runtime loader in Siemens WinCC flexible 2004, 2005, 2007, and 2008; WinCC V11 (aka TIA portal); the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime, when Transfer Mode is enabled, allows remote attackers to cause a denial of service (application crash) by sending crafted data over TCP."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2017-08-28T12:57:01.000Z",
            "orgId": "37e5125f-f79b-445b-8fad-9564f167944b",
            "shortName": "certcc"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "http://www.us-cert.gov/control_systems/pdf/ICS-ALERT-11-332-02.pdf"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "http://www.us-cert.gov/control_systems/pdf/ICS-ALERT-11-332-02A.pdf"
            },
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-345442.pdf"
            },
            {
              "name": "18166",
              "tags": [
                "exploit",
                "x_refsource_EXPLOIT-DB"
              ],
              "url": "http://www.exploit-db.com/exploits/18166"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "http://aluigi.org/adv/winccflex_1-adv.txt"
            },
            {
              "name": "simatic-hmiload-dos(71451)",
              "tags": [
                "vdb-entry",
                "x_refsource_XF"
              ],
              "url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/71451"
            },
            {
              "name": "77382",
              "tags": [
                "vdb-entry",
                "x_refsource_OSVDB"
              ],
              "url": "http://www.osvdb.org/77382"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-030-01.pdf"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cert@cert.org",
              "ID": "CVE-2011-4877",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "HmiLoad in the runtime loader in Siemens WinCC flexible 2004, 2005, 2007, and 2008; WinCC V11 (aka TIA portal); the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime, when Transfer Mode is enabled, allows remote attackers to cause a denial of service (application crash) by sending crafted data over TCP."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "http://www.us-cert.gov/control_systems/pdf/ICS-ALERT-11-332-02.pdf",
                  "refsource": "MISC",
                  "url": "http://www.us-cert.gov/control_systems/pdf/ICS-ALERT-11-332-02.pdf"
                },
                {
                  "name": "http://www.us-cert.gov/control_systems/pdf/ICS-ALERT-11-332-02A.pdf",
                  "refsource": "MISC",
                  "url": "http://www.us-cert.gov/control_systems/pdf/ICS-ALERT-11-332-02A.pdf"
                },
                {
                  "name": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-345442.pdf",
                  "refsource": "CONFIRM",
                  "url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-345442.pdf"
                },
                {
                  "name": "18166",
                  "refsource": "EXPLOIT-DB",
                  "url": "http://www.exploit-db.com/exploits/18166"
                },
                {
                  "name": "http://aluigi.org/adv/winccflex_1-adv.txt",
                  "refsource": "MISC",
                  "url": "http://aluigi.org/adv/winccflex_1-adv.txt"
                },
                {
                  "name": "simatic-hmiload-dos(71451)",
                  "refsource": "XF",
                  "url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/71451"
                },
                {
                  "name": "77382",
                  "refsource": "OSVDB",
                  "url": "http://www.osvdb.org/77382"
                },
                {
                  "name": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-030-01.pdf",
                  "refsource": "MISC",
                  "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-030-01.pdf"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "37e5125f-f79b-445b-8fad-9564f167944b",
        "assignerShortName": "certcc",
        "cveId": "CVE-2011-4877",
        "datePublished": "2012-02-03T20:00:00.000Z",
        "dateReserved": "2011-12-21T00:00:00.000Z",
        "dateUpdated": "2024-08-07T00:16:35.178Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2011-4509 (GCVE-0-2011-4509)

    Vulnerability from cvelistv5 – Published: 2012-02-03 20:00 – Updated: 2024-09-17 01:26
    VLAI
    Summary
    The HMI web server in Siemens WinCC flexible 2004, 2005, 2007, and 2008; WinCC V11 (aka TIA portal); the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime has an improperly selected default password for the administrator account, which makes it easier for remote attackers to obtain access via a brute-force approach involving many HTTP requests.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Assigner
    References
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-07T00:09:18.472Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-345442.pdf"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-030-01.pdf"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "The HMI web server in Siemens WinCC flexible 2004, 2005, 2007, and 2008; WinCC V11 (aka TIA portal); the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime has an improperly selected default password for the administrator account, which makes it easier for remote attackers to obtain access via a brute-force approach involving many HTTP requests."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2012-02-03T20:00:00.000Z",
            "orgId": "37e5125f-f79b-445b-8fad-9564f167944b",
            "shortName": "certcc"
          },
          "references": [
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-345442.pdf"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-030-01.pdf"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cert@cert.org",
              "ID": "CVE-2011-4509",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "The HMI web server in Siemens WinCC flexible 2004, 2005, 2007, and 2008; WinCC V11 (aka TIA portal); the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime has an improperly selected default password for the administrator account, which makes it easier for remote attackers to obtain access via a brute-force approach involving many HTTP requests."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-345442.pdf",
                  "refsource": "CONFIRM",
                  "url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-345442.pdf"
                },
                {
                  "name": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-030-01.pdf",
                  "refsource": "MISC",
                  "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-030-01.pdf"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "37e5125f-f79b-445b-8fad-9564f167944b",
        "assignerShortName": "certcc",
        "cveId": "CVE-2011-4509",
        "datePublished": "2012-02-03T20:00:00.000Z",
        "dateReserved": "2011-11-22T00:00:00.000Z",
        "dateUpdated": "2024-09-17T01:26:11.252Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2011-4514 (GCVE-0-2011-4514)

    Vulnerability from cvelistv5 – Published: 2012-02-03 20:00 – Updated: 2024-09-17 03:27
    VLAI
    Summary
    The TELNET daemon in Siemens WinCC flexible 2004, 2005, 2007, and 2008; WinCC V11 (aka TIA portal); the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime does not perform authentication, which makes it easier for remote attackers to obtain access via a TCP session.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Assigner
    References
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-07T00:09:18.497Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-345442.pdf"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-030-01.pdf"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "The TELNET daemon in Siemens WinCC flexible 2004, 2005, 2007, and 2008; WinCC V11 (aka TIA portal); the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime does not perform authentication, which makes it easier for remote attackers to obtain access via a TCP session."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2012-02-03T20:00:00.000Z",
            "orgId": "37e5125f-f79b-445b-8fad-9564f167944b",
            "shortName": "certcc"
          },
          "references": [
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-345442.pdf"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-030-01.pdf"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cert@cert.org",
              "ID": "CVE-2011-4514",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "The TELNET daemon in Siemens WinCC flexible 2004, 2005, 2007, and 2008; WinCC V11 (aka TIA portal); the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime does not perform authentication, which makes it easier for remote attackers to obtain access via a TCP session."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-345442.pdf",
                  "refsource": "CONFIRM",
                  "url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-345442.pdf"
                },
                {
                  "name": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-030-01.pdf",
                  "refsource": "MISC",
                  "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-030-01.pdf"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "37e5125f-f79b-445b-8fad-9564f167944b",
        "assignerShortName": "certcc",
        "cveId": "CVE-2011-4514",
        "datePublished": "2012-02-03T20:00:00.000Z",
        "dateReserved": "2011-11-22T00:00:00.000Z",
        "dateUpdated": "2024-09-17T03:27:33.362Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2011-4878 (GCVE-0-2011-4878)

    Vulnerability from cvelistv5 – Published: 2012-02-03 20:00 – Updated: 2024-08-07 00:16
    VLAI
    Summary
    Directory traversal vulnerability in miniweb.exe in the HMI web server in Siemens WinCC flexible 2004, 2005, 2007, and 2008 before SP3; WinCC V11 (aka TIA portal) before SP2 Update 1; the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime allows remote attackers to read arbitrary files via a ..%5c (dot dot backslash) in a URI.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Assigner
    Date Public
    2011-12-02 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-07T00:16:35.129Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "http://www.us-cert.gov/control_systems/pdf/ICS-ALERT-11-332-02.pdf"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "http://www.us-cert.gov/control_systems/pdf/ICS-ALERT-11-332-02A.pdf"
              },
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-345442.pdf"
              },
              {
                "name": "18166",
                "tags": [
                  "exploit",
                  "x_refsource_EXPLOIT-DB",
                  "x_transferred"
                ],
                "url": "http://www.exploit-db.com/exploits/18166"
              },
              {
                "name": "simatic-miniweb-directory-traversal(71452)",
                "tags": [
                  "vdb-entry",
                  "x_refsource_XF",
                  "x_transferred"
                ],
                "url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/71452"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "http://aluigi.org/adv/winccflex_1-adv.txt"
              },
              {
                "name": "77383",
                "tags": [
                  "vdb-entry",
                  "x_refsource_OSVDB",
                  "x_transferred"
                ],
                "url": "http://www.osvdb.org/77383"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-030-01.pdf"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "datePublic": "2011-12-02T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "Directory traversal vulnerability in miniweb.exe in the HMI web server in Siemens WinCC flexible 2004, 2005, 2007, and 2008 before SP3; WinCC V11 (aka TIA portal) before SP2 Update 1; the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime allows remote attackers to read arbitrary files via a ..%5c (dot dot backslash) in a URI."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2017-08-28T12:57:01.000Z",
            "orgId": "37e5125f-f79b-445b-8fad-9564f167944b",
            "shortName": "certcc"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "http://www.us-cert.gov/control_systems/pdf/ICS-ALERT-11-332-02.pdf"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "http://www.us-cert.gov/control_systems/pdf/ICS-ALERT-11-332-02A.pdf"
            },
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-345442.pdf"
            },
            {
              "name": "18166",
              "tags": [
                "exploit",
                "x_refsource_EXPLOIT-DB"
              ],
              "url": "http://www.exploit-db.com/exploits/18166"
            },
            {
              "name": "simatic-miniweb-directory-traversal(71452)",
              "tags": [
                "vdb-entry",
                "x_refsource_XF"
              ],
              "url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/71452"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "http://aluigi.org/adv/winccflex_1-adv.txt"
            },
            {
              "name": "77383",
              "tags": [
                "vdb-entry",
                "x_refsource_OSVDB"
              ],
              "url": "http://www.osvdb.org/77383"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-030-01.pdf"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cert@cert.org",
              "ID": "CVE-2011-4878",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Directory traversal vulnerability in miniweb.exe in the HMI web server in Siemens WinCC flexible 2004, 2005, 2007, and 2008 before SP3; WinCC V11 (aka TIA portal) before SP2 Update 1; the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime allows remote attackers to read arbitrary files via a ..%5c (dot dot backslash) in a URI."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "http://www.us-cert.gov/control_systems/pdf/ICS-ALERT-11-332-02.pdf",
                  "refsource": "MISC",
                  "url": "http://www.us-cert.gov/control_systems/pdf/ICS-ALERT-11-332-02.pdf"
                },
                {
                  "name": "http://www.us-cert.gov/control_systems/pdf/ICS-ALERT-11-332-02A.pdf",
                  "refsource": "MISC",
                  "url": "http://www.us-cert.gov/control_systems/pdf/ICS-ALERT-11-332-02A.pdf"
                },
                {
                  "name": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-345442.pdf",
                  "refsource": "CONFIRM",
                  "url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-345442.pdf"
                },
                {
                  "name": "18166",
                  "refsource": "EXPLOIT-DB",
                  "url": "http://www.exploit-db.com/exploits/18166"
                },
                {
                  "name": "simatic-miniweb-directory-traversal(71452)",
                  "refsource": "XF",
                  "url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/71452"
                },
                {
                  "name": "http://aluigi.org/adv/winccflex_1-adv.txt",
                  "refsource": "MISC",
                  "url": "http://aluigi.org/adv/winccflex_1-adv.txt"
                },
                {
                  "name": "77383",
                  "refsource": "OSVDB",
                  "url": "http://www.osvdb.org/77383"
                },
                {
                  "name": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-030-01.pdf",
                  "refsource": "MISC",
                  "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-030-01.pdf"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "37e5125f-f79b-445b-8fad-9564f167944b",
        "assignerShortName": "certcc",
        "cveId": "CVE-2011-4878",
        "datePublished": "2012-02-03T20:00:00.000Z",
        "dateReserved": "2011-12-21T00:00:00.000Z",
        "dateUpdated": "2024-08-07T00:16:35.129Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2011-4513 (GCVE-0-2011-4513)

    Vulnerability from cvelistv5 – Published: 2012-02-03 20:00 – Updated: 2024-09-16 22:31
    VLAI
    Summary
    Siemens WinCC flexible 2004, 2005, 2007, and 2008; WinCC V11 (aka TIA portal); the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime allow user-assisted remote attackers to execute arbitrary code via a crafted project file, related to the HMI web server and runtime loader.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Assigner
    References
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-07T00:09:18.521Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-345442.pdf"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-030-01.pdf"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Siemens WinCC flexible 2004, 2005, 2007, and 2008; WinCC V11 (aka TIA portal); the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime allow user-assisted remote attackers to execute arbitrary code via a crafted project file, related to the HMI web server and runtime loader."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2012-02-03T20:00:00.000Z",
            "orgId": "37e5125f-f79b-445b-8fad-9564f167944b",
            "shortName": "certcc"
          },
          "references": [
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-345442.pdf"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-030-01.pdf"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cert@cert.org",
              "ID": "CVE-2011-4513",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Siemens WinCC flexible 2004, 2005, 2007, and 2008; WinCC V11 (aka TIA portal); the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime allow user-assisted remote attackers to execute arbitrary code via a crafted project file, related to the HMI web server and runtime loader."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-345442.pdf",
                  "refsource": "CONFIRM",
                  "url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-345442.pdf"
                },
                {
                  "name": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-030-01.pdf",
                  "refsource": "MISC",
                  "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-030-01.pdf"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "37e5125f-f79b-445b-8fad-9564f167944b",
        "assignerShortName": "certcc",
        "cveId": "CVE-2011-4513",
        "datePublished": "2012-02-03T20:00:00.000Z",
        "dateReserved": "2011-11-22T00:00:00.000Z",
        "dateUpdated": "2024-09-16T22:31:15.150Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2011-4879 (GCVE-0-2011-4879)

    Vulnerability from cvelistv5 – Published: 2012-02-03 20:00 – Updated: 2024-08-07 00:16
    VLAI
    Summary
    miniweb.exe in the HMI web server in Siemens WinCC flexible 2004, 2005, 2007, and 2008 before SP3; WinCC V11 (aka TIA portal) before SP2 Update 1; the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime does not properly handle URIs beginning with a 0xfa character, which allows remote attackers to read data from arbitrary memory locations or cause a denial of service (application crash) via a crafted POST request.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Assigner
    Date Public
    2011-12-02 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-07T00:16:35.211Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "http://www.us-cert.gov/control_systems/pdf/ICS-ALERT-11-332-02.pdf"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "http://www.us-cert.gov/control_systems/pdf/ICS-ALERT-11-332-02A.pdf"
              },
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-345442.pdf"
              },
              {
                "name": "18166",
                "tags": [
                  "exploit",
                  "x_refsource_EXPLOIT-DB",
                  "x_transferred"
                ],
                "url": "http://www.exploit-db.com/exploits/18166"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "http://aluigi.org/adv/winccflex_1-adv.txt"
              },
              {
                "name": "77384",
                "tags": [
                  "vdb-entry",
                  "x_refsource_OSVDB",
                  "x_transferred"
                ],
                "url": "http://www.osvdb.org/77384"
              },
              {
                "name": "simatic-miniweb-dos(71453)",
                "tags": [
                  "vdb-entry",
                  "x_refsource_XF",
                  "x_transferred"
                ],
                "url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/71453"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-030-01.pdf"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "datePublic": "2011-12-02T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "miniweb.exe in the HMI web server in Siemens WinCC flexible 2004, 2005, 2007, and 2008 before SP3; WinCC V11 (aka TIA portal) before SP2 Update 1; the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime does not properly handle URIs beginning with a 0xfa character, which allows remote attackers to read data from arbitrary memory locations or cause a denial of service (application crash) via a crafted POST request."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2017-08-28T12:57:01.000Z",
            "orgId": "37e5125f-f79b-445b-8fad-9564f167944b",
            "shortName": "certcc"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "http://www.us-cert.gov/control_systems/pdf/ICS-ALERT-11-332-02.pdf"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "http://www.us-cert.gov/control_systems/pdf/ICS-ALERT-11-332-02A.pdf"
            },
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-345442.pdf"
            },
            {
              "name": "18166",
              "tags": [
                "exploit",
                "x_refsource_EXPLOIT-DB"
              ],
              "url": "http://www.exploit-db.com/exploits/18166"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "http://aluigi.org/adv/winccflex_1-adv.txt"
            },
            {
              "name": "77384",
              "tags": [
                "vdb-entry",
                "x_refsource_OSVDB"
              ],
              "url": "http://www.osvdb.org/77384"
            },
            {
              "name": "simatic-miniweb-dos(71453)",
              "tags": [
                "vdb-entry",
                "x_refsource_XF"
              ],
              "url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/71453"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-030-01.pdf"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cert@cert.org",
              "ID": "CVE-2011-4879",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "miniweb.exe in the HMI web server in Siemens WinCC flexible 2004, 2005, 2007, and 2008 before SP3; WinCC V11 (aka TIA portal) before SP2 Update 1; the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime does not properly handle URIs beginning with a 0xfa character, which allows remote attackers to read data from arbitrary memory locations or cause a denial of service (application crash) via a crafted POST request."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "http://www.us-cert.gov/control_systems/pdf/ICS-ALERT-11-332-02.pdf",
                  "refsource": "MISC",
                  "url": "http://www.us-cert.gov/control_systems/pdf/ICS-ALERT-11-332-02.pdf"
                },
                {
                  "name": "http://www.us-cert.gov/control_systems/pdf/ICS-ALERT-11-332-02A.pdf",
                  "refsource": "MISC",
                  "url": "http://www.us-cert.gov/control_systems/pdf/ICS-ALERT-11-332-02A.pdf"
                },
                {
                  "name": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-345442.pdf",
                  "refsource": "CONFIRM",
                  "url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-345442.pdf"
                },
                {
                  "name": "18166",
                  "refsource": "EXPLOIT-DB",
                  "url": "http://www.exploit-db.com/exploits/18166"
                },
                {
                  "name": "http://aluigi.org/adv/winccflex_1-adv.txt",
                  "refsource": "MISC",
                  "url": "http://aluigi.org/adv/winccflex_1-adv.txt"
                },
                {
                  "name": "77384",
                  "refsource": "OSVDB",
                  "url": "http://www.osvdb.org/77384"
                },
                {
                  "name": "simatic-miniweb-dos(71453)",
                  "refsource": "XF",
                  "url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/71453"
                },
                {
                  "name": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-030-01.pdf",
                  "refsource": "MISC",
                  "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-030-01.pdf"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "37e5125f-f79b-445b-8fad-9564f167944b",
        "assignerShortName": "certcc",
        "cveId": "CVE-2011-4879",
        "datePublished": "2012-02-03T20:00:00.000Z",
        "dateReserved": "2011-12-21T00:00:00.000Z",
        "dateUpdated": "2024-08-07T00:16:35.211Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2011-4876 (GCVE-0-2011-4876)

    Vulnerability from cvelistv5 – Published: 2012-02-03 20:00 – Updated: 2024-08-07 00:16
    VLAI
    Summary
    Directory traversal vulnerability in HmiLoad in the runtime loader in Siemens WinCC flexible 2004, 2005, 2007, and 2008; WinCC V11 (aka TIA portal); the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime, when Transfer Mode is enabled, allows remote attackers to execute, read, create, modify, or delete arbitrary files via a .. (dot dot) in a string.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Assigner
    Date Public
    2011-12-02 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-07T00:16:35.056Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "name": "46997",
                "tags": [
                  "third-party-advisory",
                  "x_refsource_SECUNIA",
                  "x_transferred"
                ],
                "url": "http://secunia.com/advisories/46997"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "http://www.us-cert.gov/control_systems/pdf/ICS-ALERT-11-332-02.pdf"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "http://www.us-cert.gov/control_systems/pdf/ICS-ALERT-11-332-02A.pdf"
              },
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-345442.pdf"
              },
              {
                "name": "18166",
                "tags": [
                  "exploit",
                  "x_refsource_EXPLOIT-DB",
                  "x_transferred"
                ],
                "url": "http://www.exploit-db.com/exploits/18166"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "http://aluigi.org/adv/winccflex_1-adv.txt"
              },
              {
                "name": "simatic-hmiload-dir-traversal(71450)",
                "tags": [
                  "vdb-entry",
                  "x_refsource_XF",
                  "x_transferred"
                ],
                "url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/71450"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-030-01.pdf"
              },
              {
                "name": "77381",
                "tags": [
                  "vdb-entry",
                  "x_refsource_OSVDB",
                  "x_transferred"
                ],
                "url": "http://www.osvdb.org/77381"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "datePublic": "2011-12-02T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "Directory traversal vulnerability in HmiLoad in the runtime loader in Siemens WinCC flexible 2004, 2005, 2007, and 2008; WinCC V11 (aka TIA portal); the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime, when Transfer Mode is enabled, allows remote attackers to execute, read, create, modify, or delete arbitrary files via a .. (dot dot) in a string."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2017-08-28T12:57:01.000Z",
            "orgId": "37e5125f-f79b-445b-8fad-9564f167944b",
            "shortName": "certcc"
          },
          "references": [
            {
              "name": "46997",
              "tags": [
                "third-party-advisory",
                "x_refsource_SECUNIA"
              ],
              "url": "http://secunia.com/advisories/46997"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "http://www.us-cert.gov/control_systems/pdf/ICS-ALERT-11-332-02.pdf"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "http://www.us-cert.gov/control_systems/pdf/ICS-ALERT-11-332-02A.pdf"
            },
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-345442.pdf"
            },
            {
              "name": "18166",
              "tags": [
                "exploit",
                "x_refsource_EXPLOIT-DB"
              ],
              "url": "http://www.exploit-db.com/exploits/18166"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "http://aluigi.org/adv/winccflex_1-adv.txt"
            },
            {
              "name": "simatic-hmiload-dir-traversal(71450)",
              "tags": [
                "vdb-entry",
                "x_refsource_XF"
              ],
              "url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/71450"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-030-01.pdf"
            },
            {
              "name": "77381",
              "tags": [
                "vdb-entry",
                "x_refsource_OSVDB"
              ],
              "url": "http://www.osvdb.org/77381"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cert@cert.org",
              "ID": "CVE-2011-4876",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Directory traversal vulnerability in HmiLoad in the runtime loader in Siemens WinCC flexible 2004, 2005, 2007, and 2008; WinCC V11 (aka TIA portal); the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime, when Transfer Mode is enabled, allows remote attackers to execute, read, create, modify, or delete arbitrary files via a .. (dot dot) in a string."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "46997",
                  "refsource": "SECUNIA",
                  "url": "http://secunia.com/advisories/46997"
                },
                {
                  "name": "http://www.us-cert.gov/control_systems/pdf/ICS-ALERT-11-332-02.pdf",
                  "refsource": "MISC",
                  "url": "http://www.us-cert.gov/control_systems/pdf/ICS-ALERT-11-332-02.pdf"
                },
                {
                  "name": "http://www.us-cert.gov/control_systems/pdf/ICS-ALERT-11-332-02A.pdf",
                  "refsource": "MISC",
                  "url": "http://www.us-cert.gov/control_systems/pdf/ICS-ALERT-11-332-02A.pdf"
                },
                {
                  "name": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-345442.pdf",
                  "refsource": "CONFIRM",
                  "url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-345442.pdf"
                },
                {
                  "name": "18166",
                  "refsource": "EXPLOIT-DB",
                  "url": "http://www.exploit-db.com/exploits/18166"
                },
                {
                  "name": "http://aluigi.org/adv/winccflex_1-adv.txt",
                  "refsource": "MISC",
                  "url": "http://aluigi.org/adv/winccflex_1-adv.txt"
                },
                {
                  "name": "simatic-hmiload-dir-traversal(71450)",
                  "refsource": "XF",
                  "url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/71450"
                },
                {
                  "name": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-030-01.pdf",
                  "refsource": "MISC",
                  "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-030-01.pdf"
                },
                {
                  "name": "77381",
                  "refsource": "OSVDB",
                  "url": "http://www.osvdb.org/77381"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "37e5125f-f79b-445b-8fad-9564f167944b",
        "assignerShortName": "certcc",
        "cveId": "CVE-2011-4876",
        "datePublished": "2012-02-03T20:00:00.000Z",
        "dateReserved": "2011-12-21T00:00:00.000Z",
        "dateUpdated": "2024-08-07T00:16:35.056Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2011-4512 (GCVE-0-2011-4512)

    Vulnerability from cvelistv5 – Published: 2012-02-03 20:00 – Updated: 2024-09-16 18:09
    VLAI
    Summary
    CRLF injection vulnerability in the HMI web server in Siemens WinCC flexible 2004, 2005, 2007, and 2008 before SP3; WinCC V11 (aka TIA portal) before SP2 Update 1; the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime allows remote attackers to inject arbitrary HTTP headers and conduct HTTP response splitting attacks via unspecified vectors.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Assigner
    References
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-07T00:09:18.437Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-345442.pdf"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-030-01.pdf"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "CRLF injection vulnerability in the HMI web server in Siemens WinCC flexible 2004, 2005, 2007, and 2008 before SP3; WinCC V11 (aka TIA portal) before SP2 Update 1; the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime allows remote attackers to inject arbitrary HTTP headers and conduct HTTP response splitting attacks via unspecified vectors."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2012-02-03T20:00:00.000Z",
            "orgId": "37e5125f-f79b-445b-8fad-9564f167944b",
            "shortName": "certcc"
          },
          "references": [
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-345442.pdf"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-030-01.pdf"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cert@cert.org",
              "ID": "CVE-2011-4512",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "CRLF injection vulnerability in the HMI web server in Siemens WinCC flexible 2004, 2005, 2007, and 2008 before SP3; WinCC V11 (aka TIA portal) before SP2 Update 1; the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime allows remote attackers to inject arbitrary HTTP headers and conduct HTTP response splitting attacks via unspecified vectors."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-345442.pdf",
                  "refsource": "CONFIRM",
                  "url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-345442.pdf"
                },
                {
                  "name": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-030-01.pdf",
                  "refsource": "MISC",
                  "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-030-01.pdf"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "37e5125f-f79b-445b-8fad-9564f167944b",
        "assignerShortName": "certcc",
        "cveId": "CVE-2011-4512",
        "datePublished": "2012-02-03T20:00:00.000Z",
        "dateReserved": "2011-11-22T00:00:00.000Z",
        "dateUpdated": "2024-09-16T18:09:01.418Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }