    9 vulnerabilities found for wi-fi_blood_pressure_monitor_firmware by blipcare

    FKIE_CVE-2017-11580

    Vulnerability from fkie_nvd - Published: 2019-07-02 21:15 - Updated: 2026-06-17 01:02
    Summary
    Blipcare Wifi blood pressure monitor BP700 10.1 devices allow memory corruption that results in Denial of Service. When connected to the "Blip" open wireless connection provided by the device, if a large string is sent as a part of the HTTP request in any part of the HTTP headers, the device could become completely unresponsive. Presumably this happens as the memory footprint provided to this device is very small. According to the specs from Rezolt, the Wi-Fi module only has 256k of memory. As a result, an incorrect string copy operation using either memcpy, strcpy, or any of their other variants could result in filling up the memory space allocated to the function executing and this would result in memory corruption. To test the theory, one can modify the demo application provided by the Cypress WICED SDK and introduce an incorrect "memcpy" operation and use the compiled application on the evaluation board provided by Cypress semiconductors with exactly the same Wi-Fi SOC. The results were identical where the device would completely stop responding to any of the ping or web requests.

    {
      "affected": [
        {
          "affectedData": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "source": "cve@mitre.org"
        }
      ],
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:blipcare:wi-fi_blood_pressure_monitor_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "AFBC8640-C65D-4A08-90C9-1DEAEE598C91",
                  "versionEndIncluding": "bp700_10.1",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:blipcare:wi-fi_blood_pressure_monitor:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "BB414505-7BE8-463E-B036-16B53ADED4AA",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        }
      ],
      "cveTags": [],
      "descriptions": [
        {
          "lang": "en",
          "value": "Blipcare Wifi blood pressure monitor BP700 10.1 devices allow memory corruption that results in Denial of Service. When connected to the \"Blip\" open wireless connection provided by the device, if a large string is sent as a part of the HTTP request in any part of the HTTP headers, the device could become completely unresponsive. Presumably this happens as the memory footprint provided to this device is very small. According to the specs from Rezolt, the Wi-Fi module only has 256k of memory. As a result, an incorrect string copy operation using either memcpy, strcpy, or any of their other variants could result in filling up the memory space allocated to the function executing and this would result in memory corruption. To test the theory, one can modify the demo application provided by the Cypress WICED SDK and introduce an incorrect \"memcpy\" operation and use the compiled application on the evaluation board provided by Cypress semiconductors with exactly the same Wi-Fi SOC. The results were identical where the device would completely stop responding to any of the ping or web requests."
        },
        {
          "lang": "es",
          "value": "El monitor de presi\u00f3n Wifi blood BP700 versi\u00f3n 10.1 de Blipcare, permite la corrupci\u00f3n de memoria que resulta en la Denegaci\u00f3n de Servicio. Cuando est\u00e1 conectado a la conexi\u00f3n inal\u00e1mbrica abierta \"Blip\" proporcionada por el dispositivo, si se env\u00eda una cadena larga como parte de la petici\u00f3n HTTP en cualquier parte de los encabezados HTTP, el dispositivo podr\u00eda dejar de responder por completo. Presuntamente esto sucede ya que la huella de memoria suministrada a este dispositivo es muy peque\u00f1a. De acuerdo con las especificaciones de Rezolt, el m\u00f3dulo Wi-Fi solo tiene 256k de memoria. Como resultado, una operaci\u00f3n de copia de cadena incorrecta que usando memcpy, strcpy o cualquiera de sus otras variantes podr\u00eda resultar en el llenado del espacio de memoria asignado a la funci\u00f3n que se ejecuta y esto podr\u00eda provocar una corrupci\u00f3n de la memoria. Para probar la teor\u00eda, uno puede modificar la aplicaci\u00f3n de demostraci\u00f3n provista por el WICED SDK de Cypress e introducir una operaci\u00f3n \"memcpy\" incorrecta y utilizar la aplicaci\u00f3n compilada en la placa de evaluaci\u00f3n suministrada por los semiconductores Cypress con exactamente el mismo SOC de Wi-Fi. Los resultados fueron id\u00e9nticos donde el dispositivo se detendr\u00eda completamente a cualquiera de las peticiones web o de ping."
        }
      ],
      "id": "CVE-2017-11580",
      "lastModified": "2026-06-17T01:02:02.673",
      "metrics": {
        "cvssMetricV2": [
          {
            "acInsufInfo": false,
            "baseSeverity": "MEDIUM",
            "cvssData": {
              "accessComplexity": "LOW",
              "accessVector": "ADJACENT_NETWORK",
              "authentication": "NONE",
              "availabilityImpact": "COMPLETE",
              "baseScore": 6.1,
              "confidentialityImpact": "NONE",
              "integrityImpact": "NONE",
              "vectorString": "AV:A/AC:L/Au:N/C:N/I:N/A:C",
              "version": "2.0"
            },
            "exploitabilityScore": 6.5,
            "impactScore": 6.9,
            "obtainAllPrivilege": false,
            "obtainOtherPrivilege": false,
            "obtainUserPrivilege": false,
            "source": "nvd@nist.gov",
            "type": "Primary",
            "userInteractionRequired": false
          }
        ],
        "cvssMetricV30": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "ADJACENT_NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 6.5,
              "baseSeverity": "MEDIUM",
              "confidentialityImpact": "NONE",
              "integrityImpact": "NONE",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
              "version": "3.0"
            },
            "exploitabilityScore": 2.8,
            "impactScore": 3.6,
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ]
      },
      "published": "2019-07-02T21:15:10.010",
      "references": [
        {
          "source": "cve@mitre.org",
          "tags": [
            "Third Party Advisory",
            "VDB Entry"
          ],
          "url": "http://packetstormsecurity.com/files/153225/Blipcare-Clear-Text-Communication-Memory-Corruption.html"
        },
        {
          "source": "cve@mitre.org",
          "tags": [
            "Exploit",
            "Third Party Advisory"
          ],
          "url": "https://github.com/ethanhunnt/IoT_vulnerabilities/blob/master/Blipcare_sec_issues.pdf"
        },
        {
          "source": "cve@mitre.org",
          "tags": [
            "Mailing List",
            "Third Party Advisory"
          ],
          "url": "https://seclists.org/bugtraq/2019/Jun/8"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory",
            "VDB Entry"
          ],
          "url": "http://packetstormsecurity.com/files/153225/Blipcare-Clear-Text-Communication-Memory-Corruption.html"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Exploit",
            "Third Party Advisory"
          ],
          "url": "https://github.com/ethanhunnt/IoT_vulnerabilities/blob/master/Blipcare_sec_issues.pdf"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Mailing List",
            "Third Party Advisory"
          ],
          "url": "https://seclists.org/bugtraq/2019/Jun/8"
        }
      ],
      "sourceIdentifier": "cve@mitre.org",
      "vulnStatus": "Modified",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-399"
            }
          ],
          "source": "nvd@nist.gov",
          "type": "Primary"
        }
      ]
    }

    FKIE_CVE-2017-11579

    Vulnerability from fkie_nvd - Published: 2019-07-02 21:15 - Updated: 2026-06-17 01:02
    Summary
    In the most recent firmware for Blipcare, the device provides an open Wireless network called "Blip" for communicating with the device. The user connects to this open Wireless network and uses the web management interface of the device to provide the user's Wi-Fi credentials so that the device can connect to it and have Internet access. This device acts as a Wireless Blood pressure monitor and is used to measure blood pressure levels of a person. This allows an attacker who is in vicinity of Wireless signal generated by the Blipcare device to easily sniff the credentials. Also, an attacker can connect to the open wireless network "Blip" exposed by the device and modify the HTTP response presented to the user by the device to execute other attacks such as convincing the user to download and execute a malicious binary that would infect a user's computer or mobile device with malware.

    {
      "affected": [
        {
          "affectedData": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "source": "cve@mitre.org"
        }
      ],
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:blipcare:wi-fi_blood_pressure_monitor_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "AFBC8640-C65D-4A08-90C9-1DEAEE598C91",
                  "versionEndIncluding": "bp700_10.1",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:blipcare:wi-fi_blood_pressure_monitor:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "BB414505-7BE8-463E-B036-16B53ADED4AA",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        }
      ],
      "cveTags": [],
      "descriptions": [
        {
          "lang": "en",
          "value": "In the most recent firmware for Blipcare, the device provides an open Wireless network called \"Blip\" for communicating with the device. The user connects to this open Wireless network and uses the web management interface of the device to provide the user\u0027s Wi-Fi credentials so that the device can connect to it and have Internet access. This device acts as a Wireless Blood pressure monitor and is used to measure blood pressure levels of a person. This allows an attacker who is in vicinity of Wireless signal generated by the Blipcare device to easily sniff the credentials. Also, an attacker can connect to the open wireless network \"Blip\" exposed by the device and modify the HTTP response presented to the user by the device to execute other attacks such as convincing the user to download and execute a malicious binary that would infect a user\u0027s computer or mobile device with malware."
        },
        {
          "lang": "es",
          "value": "En el firmware m\u00e1s reciente para Blipcare, el dispositivo provee una red inal\u00e1mbrica abierta llamada \"Blip\" para comunicarse con el dispositivo. El usuario se conecta a esta red inal\u00e1mbrica abierta y utiliza la interfaz de administraci\u00f3n web del dispositivo para proporcionar las credenciales de Wi-Fi del usuario para que el dispositivo pueda conectarse a \u00e9l y tener acceso a Internet. Este dispositivo act\u00faa como un monitor de presi\u00f3n Sangu\u00ednea Inal\u00e1mbrico y es usado para medir los niveles de presi\u00f3n sangu\u00ednea de una persona. Esto permite a un atacante que est\u00e9 cerca de la se\u00f1al inal\u00e1mbrica generada por el dispositivo Blipcare poder espiar f\u00e1cilmente las credenciales. Adicionalmente, un atacante puede conectarse a la red inal\u00e1mbrica abierta \"Blip\" expuesta por el dispositivo y modificar la respuesta HTTP presentada al usuario mediante el dispositivo para ejecutar otros ataques, tales como convencer al usuario de descargar y ejecutar un binario malicioso que infectar\u00eda con malware a un ordenador o dispositivo m\u00f3vil del usuario."
        }
      ],
      "id": "CVE-2017-11579",
      "lastModified": "2026-06-17T01:02:02.543",
      "metrics": {
        "cvssMetricV2": [
          {
            "acInsufInfo": false,
            "baseSeverity": "MEDIUM",
            "cvssData": {
              "accessComplexity": "LOW",
              "accessVector": "ADJACENT_NETWORK",
              "authentication": "NONE",
              "availabilityImpact": "NONE",
              "baseScore": 4.8,
              "confidentialityImpact": "PARTIAL",
              "integrityImpact": "PARTIAL",
              "vectorString": "AV:A/AC:L/Au:N/C:P/I:P/A:N",
              "version": "2.0"
            },
            "exploitabilityScore": 6.5,
            "impactScore": 4.9,
            "obtainAllPrivilege": false,
            "obtainOtherPrivilege": false,
            "obtainUserPrivilege": false,
            "source": "nvd@nist.gov",
            "type": "Primary",
            "userInteractionRequired": false
          }
        ],
        "cvssMetricV30": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "ADJACENT_NETWORK",
              "availabilityImpact": "NONE",
              "baseScore": 7.1,
              "baseSeverity": "HIGH",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "LOW",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:L/A:N",
              "version": "3.0"
            },
            "exploitabilityScore": 2.8,
            "impactScore": 4.2,
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ]
      },
      "published": "2019-07-02T21:15:09.930",
      "references": [
        {
          "source": "cve@mitre.org",
          "tags": [
            "Third Party Advisory",
            "VDB Entry"
          ],
          "url": "http://packetstormsecurity.com/files/153225/Blipcare-Clear-Text-Communication-Memory-Corruption.html"
        },
        {
          "source": "cve@mitre.org",
          "tags": [
            "Exploit",
            "Third Party Advisory"
          ],
          "url": "https://github.com/ethanhunnt/IoT_vulnerabilities/blob/master/Blipcare_sec_issues.pdf"
        },
        {
          "source": "cve@mitre.org",
          "tags": [
            "Mailing List",
            "Third Party Advisory"
          ],
          "url": "https://seclists.org/bugtraq/2019/Jun/8"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory",
            "VDB Entry"
          ],
          "url": "http://packetstormsecurity.com/files/153225/Blipcare-Clear-Text-Communication-Memory-Corruption.html"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Exploit",
            "Third Party Advisory"
          ],
          "url": "https://github.com/ethanhunnt/IoT_vulnerabilities/blob/master/Blipcare_sec_issues.pdf"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Mailing List",
            "Third Party Advisory"
          ],
          "url": "https://seclists.org/bugtraq/2019/Jun/8"
        }
      ],
      "sourceIdentifier": "cve@mitre.org",
      "vulnStatus": "Modified",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-254"
            }
          ],
          "source": "nvd@nist.gov",
          "type": "Primary"
        }
      ]
    }

    FKIE_CVE-2017-11578

    Vulnerability from fkie_nvd - Published: 2019-07-02 21:15 - Updated: 2026-06-17 01:02
    Summary
    It was discovered as a part of the research on IoT devices in the most recent firmware for Blipcare device that the device allows to connect to web management interface on a non-SSL connection using plain text HTTP protocol. The user uses the web management interface of the device to provide the user's Wi-Fi credentials so that the device can connect to it and have Internet access. This device acts as a Wireless Blood pressure monitor and is used to measure blood pressure levels of a person. This allows an attacker who is connected to the Blipcare's device wireless network to easily sniff these values using a MITM attack.

    {
      "affected": [
        {
          "affectedData": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "source": "cve@mitre.org"
        }
      ],
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:blipcare:wi-fi_blood_pressure_monitor_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "AFBC8640-C65D-4A08-90C9-1DEAEE598C91",
                  "versionEndIncluding": "bp700_10.1",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:blipcare:wi-fi_blood_pressure_monitor:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "BB414505-7BE8-463E-B036-16B53ADED4AA",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        }
      ],
      "cveTags": [],
      "descriptions": [
        {
          "lang": "en",
          "value": "It was discovered as a part of the research on IoT devices in the most recent firmware for Blipcare device that the device allows to connect to web management interface on a non-SSL connection using plain text HTTP protocol. The user uses the web management interface of the device to provide the user\u0027s Wi-Fi credentials so that the device can connect to it and have Internet access. This device acts as a Wireless Blood pressure monitor and is used to measure blood pressure levels of a person. This allows an attacker who is connected to the Blipcare\u0027s device wireless network to easily sniff these values using a MITM attack."
        },
        {
          "lang": "es",
          "value": "Se detect\u00f3 como parte de la investigaci\u00f3n sobre dispositivos IoT en el firmware m\u00e1s reciente para el dispositivo Blipcare, que el dispositivo permite conectarse a la interfaz de administraci\u00f3n web en una conexi\u00f3n no SSL usando el protocolo HTTP de texto plano. El usuario utiliza la interfaz de administraci\u00f3n web del dispositivo para proveer las credenciales Wi-Fi del usuario para que el dispositivo pueda conectarse a \u00e9l y tener acceso a Internet. Este dispositivo act\u00faa como un monitor de presi\u00f3n Sangu\u00ednea Inal\u00e1mbrico y es usado para medir los niveles de presi\u00f3n sangu\u00ednea de una persona. Esto permite a un atacante que est\u00e1 conectado a la red inal\u00e1mbrica del dispositivo Blipcare poder espiar f\u00e1cilmente estos valores mediante un ataque de tipo MITM."
        }
      ],
      "id": "CVE-2017-11578",
      "lastModified": "2026-06-17T01:02:02.417",
      "metrics": {
        "cvssMetricV2": [
          {
            "acInsufInfo": false,
            "baseSeverity": "MEDIUM",
            "cvssData": {
              "accessComplexity": "MEDIUM",
              "accessVector": "NETWORK",
              "authentication": "NONE",
              "availabilityImpact": "NONE",
              "baseScore": 4.3,
              "confidentialityImpact": "PARTIAL",
              "integrityImpact": "NONE",
              "vectorString": "AV:N/AC:M/Au:N/C:P/I:N/A:N",
              "version": "2.0"
            },
            "exploitabilityScore": 8.6,
            "impactScore": 2.9,
            "obtainAllPrivilege": false,
            "obtainOtherPrivilege": false,
            "obtainUserPrivilege": false,
            "source": "nvd@nist.gov",
            "type": "Primary",
            "userInteractionRequired": false
          }
        ],
        "cvssMetricV30": [
          {
            "cvssData": {
              "attackComplexity": "HIGH",
              "attackVector": "NETWORK",
              "availabilityImpact": "NONE",
              "baseScore": 5.9,
              "baseSeverity": "MEDIUM",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "NONE",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:N/A:N",
              "version": "3.0"
            },
            "exploitabilityScore": 2.2,
            "impactScore": 3.6,
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ]
      },
      "published": "2019-07-02T21:15:09.870",
      "references": [
        {
          "source": "cve@mitre.org",
          "tags": [
            "Third Party Advisory",
            "VDB Entry"
          ],
          "url": "http://packetstormsecurity.com/files/153225/Blipcare-Clear-Text-Communication-Memory-Corruption.html"
        },
        {
          "source": "cve@mitre.org",
          "tags": [
            "Exploit",
            "Third Party Advisory"
          ],
          "url": "https://github.com/ethanhunnt/IoT_vulnerabilities/blob/master/Blipcare_sec_issues.pdf"
        },
        {
          "source": "cve@mitre.org",
          "tags": [
            "Mailing List",
            "Third Party Advisory"
          ],
          "url": "https://seclists.org/bugtraq/2019/Jun/8"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory",
            "VDB Entry"
          ],
          "url": "http://packetstormsecurity.com/files/153225/Blipcare-Clear-Text-Communication-Memory-Corruption.html"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Exploit",
            "Third Party Advisory"
          ],
          "url": "https://github.com/ethanhunnt/IoT_vulnerabilities/blob/master/Blipcare_sec_issues.pdf"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Mailing List",
            "Third Party Advisory"
          ],
          "url": "https://seclists.org/bugtraq/2019/Jun/8"
        }
      ],
      "sourceIdentifier": "cve@mitre.org",
      "vulnStatus": "Modified",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-200"
            }
          ],
          "source": "nvd@nist.gov",
          "type": "Primary"
        }
      ]
    }

    CVE-2017-11580 (GCVE-0-2017-11580)

    Vulnerability from nvd – Published: 2019-07-02 20:49 – Updated: 2024-08-05 18:12
    VLAI
    Summary
    Blipcare Wifi blood pressure monitor BP700 10.1 devices allow memory corruption that results in Denial of Service. When connected to the "Blip" open wireless connection provided by the device, if a large string is sent as a part of the HTTP request in any part of the HTTP headers, the device could become completely unresponsive. Presumably this happens as the memory footprint provided to this device is very small. According to the specs from Rezolt, the Wi-Fi module only has 256k of memory. As a result, an incorrect string copy operation using either memcpy, strcpy, or any of their other variants could result in filling up the memory space allocated to the function executing and this would result in memory corruption. To test the theory, one can modify the demo application provided by the Cypress WICED SDK and introduce an incorrect "memcpy" operation and use the compiled application on the evaluation board provided by Cypress semiconductors with exactly the same Wi-Fi SOC. The results were identical where the device would completely stop responding to any of the ping or web requests.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Assigner
    mitre CNA under the mitre root
    CNA scorecard E 29/100 over 2142 records in the last 180 days details
    References
    Date Public
    2019-06-07 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-05T18:12:40.635Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "name": "20190609 Newly releases IoT security issues",
                "tags": [
                  "mailing-list",
                  "x_refsource_BUGTRAQ",
                  "x_transferred"
                ],
                "url": "https://seclists.org/bugtraq/2019/Jun/8"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "http://packetstormsecurity.com/files/153225/Blipcare-Clear-Text-Communication-Memory-Corruption.html"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://github.com/ethanhunnt/IoT_vulnerabilities/blob/master/Blipcare_sec_issues.pdf"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "datePublic": "2019-06-07T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "Blipcare Wifi blood pressure monitor BP700 10.1 devices allow memory corruption that results in Denial of Service. When connected to the \"Blip\" open wireless connection provided by the device, if a large string is sent as a part of the HTTP request in any part of the HTTP headers, the device could become completely unresponsive. Presumably this happens as the memory footprint provided to this device is very small. According to the specs from Rezolt, the Wi-Fi module only has 256k of memory. As a result, an incorrect string copy operation using either memcpy, strcpy, or any of their other variants could result in filling up the memory space allocated to the function executing and this would result in memory corruption. To test the theory, one can modify the demo application provided by the Cypress WICED SDK and introduce an incorrect \"memcpy\" operation and use the compiled application on the evaluation board provided by Cypress semiconductors with exactly the same Wi-Fi SOC. The results were identical where the device would completely stop responding to any of the ping or web requests."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2019-07-02T20:50:10.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "name": "20190609 Newly releases IoT security issues",
              "tags": [
                "mailing-list",
                "x_refsource_BUGTRAQ"
              ],
              "url": "https://seclists.org/bugtraq/2019/Jun/8"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "http://packetstormsecurity.com/files/153225/Blipcare-Clear-Text-Communication-Memory-Corruption.html"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://github.com/ethanhunnt/IoT_vulnerabilities/blob/master/Blipcare_sec_issues.pdf"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cve@mitre.org",
              "ID": "CVE-2017-11580",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Blipcare Wifi blood pressure monitor BP700 10.1 devices allow memory corruption that results in Denial of Service. When connected to the \"Blip\" open wireless connection provided by the device, if a large string is sent as a part of the HTTP request in any part of the HTTP headers, the device could become completely unresponsive. Presumably this happens as the memory footprint provided to this device is very small. According to the specs from Rezolt, the Wi-Fi module only has 256k of memory. As a result, an incorrect string copy operation using either memcpy, strcpy, or any of their other variants could result in filling up the memory space allocated to the function executing and this would result in memory corruption. To test the theory, one can modify the demo application provided by the Cypress WICED SDK and introduce an incorrect \"memcpy\" operation and use the compiled application on the evaluation board provided by Cypress semiconductors with exactly the same Wi-Fi SOC. The results were identical where the device would completely stop responding to any of the ping or web requests."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "20190609 Newly releases IoT security issues",
                  "refsource": "BUGTRAQ",
                  "url": "https://seclists.org/bugtraq/2019/Jun/8"
                },
                {
                  "name": "http://packetstormsecurity.com/files/153225/Blipcare-Clear-Text-Communication-Memory-Corruption.html",
                  "refsource": "MISC",
                  "url": "http://packetstormsecurity.com/files/153225/Blipcare-Clear-Text-Communication-Memory-Corruption.html"
                },
                {
                  "name": "https://github.com/ethanhunnt/IoT_vulnerabilities/blob/master/Blipcare_sec_issues.pdf",
                  "refsource": "MISC",
                  "url": "https://github.com/ethanhunnt/IoT_vulnerabilities/blob/master/Blipcare_sec_issues.pdf"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2017-11580",
        "datePublished": "2019-07-02T20:49:56.000Z",
        "dateReserved": "2017-07-23T00:00:00.000Z",
        "dateUpdated": "2024-08-05T18:12:40.635Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2017-11579 (GCVE-0-2017-11579)

    Vulnerability from nvd – Published: 2019-07-02 20:44 – Updated: 2024-08-05 18:12
    VLAI
    Summary
    In the most recent firmware for Blipcare, the device provides an open Wireless network called "Blip" for communicating with the device. The user connects to this open Wireless network and uses the web management interface of the device to provide the user's Wi-Fi credentials so that the device can connect to it and have Internet access. This device acts as a Wireless Blood pressure monitor and is used to measure blood pressure levels of a person. This allows an attacker who is in vicinity of Wireless signal generated by the Blipcare device to easily sniff the credentials. Also, an attacker can connect to the open wireless network "Blip" exposed by the device and modify the HTTP response presented to the user by the device to execute other attacks such as convincing the user to download and execute a malicious binary that would infect a user's computer or mobile device with malware.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Assigner
    mitre CNA under the mitre root
    CNA scorecard E 29/100 over 2142 records in the last 180 days details
    References
    Date Public
    2019-06-07 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-05T18:12:40.677Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "name": "20190609 Newly releases IoT security issues",
                "tags": [
                  "mailing-list",
                  "x_refsource_BUGTRAQ",
                  "x_transferred"
                ],
                "url": "https://seclists.org/bugtraq/2019/Jun/8"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "http://packetstormsecurity.com/files/153225/Blipcare-Clear-Text-Communication-Memory-Corruption.html"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://github.com/ethanhunnt/IoT_vulnerabilities/blob/master/Blipcare_sec_issues.pdf"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "datePublic": "2019-06-07T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "In the most recent firmware for Blipcare, the device provides an open Wireless network called \"Blip\" for communicating with the device. The user connects to this open Wireless network and uses the web management interface of the device to provide the user\u0027s Wi-Fi credentials so that the device can connect to it and have Internet access. This device acts as a Wireless Blood pressure monitor and is used to measure blood pressure levels of a person. This allows an attacker who is in vicinity of Wireless signal generated by the Blipcare device to easily sniff the credentials. Also, an attacker can connect to the open wireless network \"Blip\" exposed by the device and modify the HTTP response presented to the user by the device to execute other attacks such as convincing the user to download and execute a malicious binary that would infect a user\u0027s computer or mobile device with malware."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2019-07-02T20:46:59.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "name": "20190609 Newly releases IoT security issues",
              "tags": [
                "mailing-list",
                "x_refsource_BUGTRAQ"
              ],
              "url": "https://seclists.org/bugtraq/2019/Jun/8"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "http://packetstormsecurity.com/files/153225/Blipcare-Clear-Text-Communication-Memory-Corruption.html"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://github.com/ethanhunnt/IoT_vulnerabilities/blob/master/Blipcare_sec_issues.pdf"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cve@mitre.org",
              "ID": "CVE-2017-11579",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "In the most recent firmware for Blipcare, the device provides an open Wireless network called \"Blip\" for communicating with the device. The user connects to this open Wireless network and uses the web management interface of the device to provide the user\u0027s Wi-Fi credentials so that the device can connect to it and have Internet access. This device acts as a Wireless Blood pressure monitor and is used to measure blood pressure levels of a person. This allows an attacker who is in vicinity of Wireless signal generated by the Blipcare device to easily sniff the credentials. Also, an attacker can connect to the open wireless network \"Blip\" exposed by the device and modify the HTTP response presented to the user by the device to execute other attacks such as convincing the user to download and execute a malicious binary that would infect a user\u0027s computer or mobile device with malware."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "20190609 Newly releases IoT security issues",
                  "refsource": "BUGTRAQ",
                  "url": "https://seclists.org/bugtraq/2019/Jun/8"
                },
                {
                  "name": "http://packetstormsecurity.com/files/153225/Blipcare-Clear-Text-Communication-Memory-Corruption.html",
                  "refsource": "MISC",
                  "url": "http://packetstormsecurity.com/files/153225/Blipcare-Clear-Text-Communication-Memory-Corruption.html"
                },
                {
                  "name": "https://github.com/ethanhunnt/IoT_vulnerabilities/blob/master/Blipcare_sec_issues.pdf",
                  "refsource": "MISC",
                  "url": "https://github.com/ethanhunnt/IoT_vulnerabilities/blob/master/Blipcare_sec_issues.pdf"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2017-11579",
        "datePublished": "2019-07-02T20:44:51.000Z",
        "dateReserved": "2017-07-23T00:00:00.000Z",
        "dateUpdated": "2024-08-05T18:12:40.677Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2017-11578 (GCVE-0-2017-11578)

    Vulnerability from nvd – Published: 2019-07-02 20:33 – Updated: 2024-08-05 18:12
    VLAI
    Summary
    It was discovered as a part of the research on IoT devices in the most recent firmware for Blipcare device that the device allows to connect to web management interface on a non-SSL connection using plain text HTTP protocol. The user uses the web management interface of the device to provide the user's Wi-Fi credentials so that the device can connect to it and have Internet access. This device acts as a Wireless Blood pressure monitor and is used to measure blood pressure levels of a person. This allows an attacker who is connected to the Blipcare's device wireless network to easily sniff these values using a MITM attack.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Assigner
    mitre CNA under the mitre root
    CNA scorecard E 29/100 over 2142 records in the last 180 days details
    References
    Date Public
    2019-06-07 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-05T18:12:40.629Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "name": "20190609 Newly releases IoT security issues",
                "tags": [
                  "mailing-list",
                  "x_refsource_BUGTRAQ",
                  "x_transferred"
                ],
                "url": "https://seclists.org/bugtraq/2019/Jun/8"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "http://packetstormsecurity.com/files/153225/Blipcare-Clear-Text-Communication-Memory-Corruption.html"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://github.com/ethanhunnt/IoT_vulnerabilities/blob/master/Blipcare_sec_issues.pdf"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "datePublic": "2019-06-07T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "It was discovered as a part of the research on IoT devices in the most recent firmware for Blipcare device that the device allows to connect to web management interface on a non-SSL connection using plain text HTTP protocol. The user uses the web management interface of the device to provide the user\u0027s Wi-Fi credentials so that the device can connect to it and have Internet access. This device acts as a Wireless Blood pressure monitor and is used to measure blood pressure levels of a person. This allows an attacker who is connected to the Blipcare\u0027s device wireless network to easily sniff these values using a MITM attack."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2019-07-02T20:33:34.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "name": "20190609 Newly releases IoT security issues",
              "tags": [
                "mailing-list",
                "x_refsource_BUGTRAQ"
              ],
              "url": "https://seclists.org/bugtraq/2019/Jun/8"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "http://packetstormsecurity.com/files/153225/Blipcare-Clear-Text-Communication-Memory-Corruption.html"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://github.com/ethanhunnt/IoT_vulnerabilities/blob/master/Blipcare_sec_issues.pdf"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cve@mitre.org",
              "ID": "CVE-2017-11578",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "It was discovered as a part of the research on IoT devices in the most recent firmware for Blipcare device that the device allows to connect to web management interface on a non-SSL connection using plain text HTTP protocol. The user uses the web management interface of the device to provide the user\u0027s Wi-Fi credentials so that the device can connect to it and have Internet access. This device acts as a Wireless Blood pressure monitor and is used to measure blood pressure levels of a person. This allows an attacker who is connected to the Blipcare\u0027s device wireless network to easily sniff these values using a MITM attack."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "20190609 Newly releases IoT security issues",
                  "refsource": "BUGTRAQ",
                  "url": "https://seclists.org/bugtraq/2019/Jun/8"
                },
                {
                  "name": "http://packetstormsecurity.com/files/153225/Blipcare-Clear-Text-Communication-Memory-Corruption.html",
                  "refsource": "MISC",
                  "url": "http://packetstormsecurity.com/files/153225/Blipcare-Clear-Text-Communication-Memory-Corruption.html"
                },
                {
                  "name": "https://github.com/ethanhunnt/IoT_vulnerabilities/blob/master/Blipcare_sec_issues.pdf",
                  "refsource": "MISC",
                  "url": "https://github.com/ethanhunnt/IoT_vulnerabilities/blob/master/Blipcare_sec_issues.pdf"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2017-11578",
        "datePublished": "2019-07-02T20:33:14.000Z",
        "dateReserved": "2017-07-23T00:00:00.000Z",
        "dateUpdated": "2024-08-05T18:12:40.629Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2017-11580 (GCVE-0-2017-11580)

    Vulnerability from cvelistv5 – Published: 2019-07-02 20:49 – Updated: 2024-08-05 18:12
    VLAI
    Summary
    Blipcare Wifi blood pressure monitor BP700 10.1 devices allow memory corruption that results in Denial of Service. When connected to the "Blip" open wireless connection provided by the device, if a large string is sent as a part of the HTTP request in any part of the HTTP headers, the device could become completely unresponsive. Presumably this happens as the memory footprint provided to this device is very small. According to the specs from Rezolt, the Wi-Fi module only has 256k of memory. As a result, an incorrect string copy operation using either memcpy, strcpy, or any of their other variants could result in filling up the memory space allocated to the function executing and this would result in memory corruption. To test the theory, one can modify the demo application provided by the Cypress WICED SDK and introduce an incorrect "memcpy" operation and use the compiled application on the evaluation board provided by Cypress semiconductors with exactly the same Wi-Fi SOC. The results were identical where the device would completely stop responding to any of the ping or web requests.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Assigner
    mitre CNA under the mitre root
    CNA scorecard E 29/100 over 2142 records in the last 180 days details
    References
    Date Public
    2019-06-07 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-05T18:12:40.635Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "name": "20190609 Newly releases IoT security issues",
                "tags": [
                  "mailing-list",
                  "x_refsource_BUGTRAQ",
                  "x_transferred"
                ],
                "url": "https://seclists.org/bugtraq/2019/Jun/8"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "http://packetstormsecurity.com/files/153225/Blipcare-Clear-Text-Communication-Memory-Corruption.html"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://github.com/ethanhunnt/IoT_vulnerabilities/blob/master/Blipcare_sec_issues.pdf"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "datePublic": "2019-06-07T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "Blipcare Wifi blood pressure monitor BP700 10.1 devices allow memory corruption that results in Denial of Service. When connected to the \"Blip\" open wireless connection provided by the device, if a large string is sent as a part of the HTTP request in any part of the HTTP headers, the device could become completely unresponsive. Presumably this happens as the memory footprint provided to this device is very small. According to the specs from Rezolt, the Wi-Fi module only has 256k of memory. As a result, an incorrect string copy operation using either memcpy, strcpy, or any of their other variants could result in filling up the memory space allocated to the function executing and this would result in memory corruption. To test the theory, one can modify the demo application provided by the Cypress WICED SDK and introduce an incorrect \"memcpy\" operation and use the compiled application on the evaluation board provided by Cypress semiconductors with exactly the same Wi-Fi SOC. The results were identical where the device would completely stop responding to any of the ping or web requests."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2019-07-02T20:50:10.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "name": "20190609 Newly releases IoT security issues",
              "tags": [
                "mailing-list",
                "x_refsource_BUGTRAQ"
              ],
              "url": "https://seclists.org/bugtraq/2019/Jun/8"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "http://packetstormsecurity.com/files/153225/Blipcare-Clear-Text-Communication-Memory-Corruption.html"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://github.com/ethanhunnt/IoT_vulnerabilities/blob/master/Blipcare_sec_issues.pdf"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cve@mitre.org",
              "ID": "CVE-2017-11580",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Blipcare Wifi blood pressure monitor BP700 10.1 devices allow memory corruption that results in Denial of Service. When connected to the \"Blip\" open wireless connection provided by the device, if a large string is sent as a part of the HTTP request in any part of the HTTP headers, the device could become completely unresponsive. Presumably this happens as the memory footprint provided to this device is very small. According to the specs from Rezolt, the Wi-Fi module only has 256k of memory. As a result, an incorrect string copy operation using either memcpy, strcpy, or any of their other variants could result in filling up the memory space allocated to the function executing and this would result in memory corruption. To test the theory, one can modify the demo application provided by the Cypress WICED SDK and introduce an incorrect \"memcpy\" operation and use the compiled application on the evaluation board provided by Cypress semiconductors with exactly the same Wi-Fi SOC. The results were identical where the device would completely stop responding to any of the ping or web requests."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "20190609 Newly releases IoT security issues",
                  "refsource": "BUGTRAQ",
                  "url": "https://seclists.org/bugtraq/2019/Jun/8"
                },
                {
                  "name": "http://packetstormsecurity.com/files/153225/Blipcare-Clear-Text-Communication-Memory-Corruption.html",
                  "refsource": "MISC",
                  "url": "http://packetstormsecurity.com/files/153225/Blipcare-Clear-Text-Communication-Memory-Corruption.html"
                },
                {
                  "name": "https://github.com/ethanhunnt/IoT_vulnerabilities/blob/master/Blipcare_sec_issues.pdf",
                  "refsource": "MISC",
                  "url": "https://github.com/ethanhunnt/IoT_vulnerabilities/blob/master/Blipcare_sec_issues.pdf"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2017-11580",
        "datePublished": "2019-07-02T20:49:56.000Z",
        "dateReserved": "2017-07-23T00:00:00.000Z",
        "dateUpdated": "2024-08-05T18:12:40.635Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2017-11579 (GCVE-0-2017-11579)

    Vulnerability from cvelistv5 – Published: 2019-07-02 20:44 – Updated: 2024-08-05 18:12
    VLAI
    Summary
    In the most recent firmware for Blipcare, the device provides an open Wireless network called "Blip" for communicating with the device. The user connects to this open Wireless network and uses the web management interface of the device to provide the user's Wi-Fi credentials so that the device can connect to it and have Internet access. This device acts as a Wireless Blood pressure monitor and is used to measure blood pressure levels of a person. This allows an attacker who is in vicinity of Wireless signal generated by the Blipcare device to easily sniff the credentials. Also, an attacker can connect to the open wireless network "Blip" exposed by the device and modify the HTTP response presented to the user by the device to execute other attacks such as convincing the user to download and execute a malicious binary that would infect a user's computer or mobile device with malware.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Assigner
    mitre CNA under the mitre root
    CNA scorecard E 29/100 over 2142 records in the last 180 days details
    References
    Date Public
    2019-06-07 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-05T18:12:40.677Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "name": "20190609 Newly releases IoT security issues",
                "tags": [
                  "mailing-list",
                  "x_refsource_BUGTRAQ",
                  "x_transferred"
                ],
                "url": "https://seclists.org/bugtraq/2019/Jun/8"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "http://packetstormsecurity.com/files/153225/Blipcare-Clear-Text-Communication-Memory-Corruption.html"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://github.com/ethanhunnt/IoT_vulnerabilities/blob/master/Blipcare_sec_issues.pdf"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "datePublic": "2019-06-07T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "In the most recent firmware for Blipcare, the device provides an open Wireless network called \"Blip\" for communicating with the device. The user connects to this open Wireless network and uses the web management interface of the device to provide the user\u0027s Wi-Fi credentials so that the device can connect to it and have Internet access. This device acts as a Wireless Blood pressure monitor and is used to measure blood pressure levels of a person. This allows an attacker who is in vicinity of Wireless signal generated by the Blipcare device to easily sniff the credentials. Also, an attacker can connect to the open wireless network \"Blip\" exposed by the device and modify the HTTP response presented to the user by the device to execute other attacks such as convincing the user to download and execute a malicious binary that would infect a user\u0027s computer or mobile device with malware."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2019-07-02T20:46:59.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "name": "20190609 Newly releases IoT security issues",
              "tags": [
                "mailing-list",
                "x_refsource_BUGTRAQ"
              ],
              "url": "https://seclists.org/bugtraq/2019/Jun/8"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "http://packetstormsecurity.com/files/153225/Blipcare-Clear-Text-Communication-Memory-Corruption.html"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://github.com/ethanhunnt/IoT_vulnerabilities/blob/master/Blipcare_sec_issues.pdf"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cve@mitre.org",
              "ID": "CVE-2017-11579",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "In the most recent firmware for Blipcare, the device provides an open Wireless network called \"Blip\" for communicating with the device. The user connects to this open Wireless network and uses the web management interface of the device to provide the user\u0027s Wi-Fi credentials so that the device can connect to it and have Internet access. This device acts as a Wireless Blood pressure monitor and is used to measure blood pressure levels of a person. This allows an attacker who is in vicinity of Wireless signal generated by the Blipcare device to easily sniff the credentials. Also, an attacker can connect to the open wireless network \"Blip\" exposed by the device and modify the HTTP response presented to the user by the device to execute other attacks such as convincing the user to download and execute a malicious binary that would infect a user\u0027s computer or mobile device with malware."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "20190609 Newly releases IoT security issues",
                  "refsource": "BUGTRAQ",
                  "url": "https://seclists.org/bugtraq/2019/Jun/8"
                },
                {
                  "name": "http://packetstormsecurity.com/files/153225/Blipcare-Clear-Text-Communication-Memory-Corruption.html",
                  "refsource": "MISC",
                  "url": "http://packetstormsecurity.com/files/153225/Blipcare-Clear-Text-Communication-Memory-Corruption.html"
                },
                {
                  "name": "https://github.com/ethanhunnt/IoT_vulnerabilities/blob/master/Blipcare_sec_issues.pdf",
                  "refsource": "MISC",
                  "url": "https://github.com/ethanhunnt/IoT_vulnerabilities/blob/master/Blipcare_sec_issues.pdf"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2017-11579",
        "datePublished": "2019-07-02T20:44:51.000Z",
        "dateReserved": "2017-07-23T00:00:00.000Z",
        "dateUpdated": "2024-08-05T18:12:40.677Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2017-11578 (GCVE-0-2017-11578)

    Vulnerability from cvelistv5 – Published: 2019-07-02 20:33 – Updated: 2024-08-05 18:12
    VLAI
    Summary
    It was discovered as a part of the research on IoT devices in the most recent firmware for Blipcare device that the device allows to connect to web management interface on a non-SSL connection using plain text HTTP protocol. The user uses the web management interface of the device to provide the user's Wi-Fi credentials so that the device can connect to it and have Internet access. This device acts as a Wireless Blood pressure monitor and is used to measure blood pressure levels of a person. This allows an attacker who is connected to the Blipcare's device wireless network to easily sniff these values using a MITM attack.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Assigner
    mitre CNA under the mitre root
    CNA scorecard E 29/100 over 2142 records in the last 180 days details
    References
    Date Public
    2019-06-07 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-05T18:12:40.629Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "name": "20190609 Newly releases IoT security issues",
                "tags": [
                  "mailing-list",
                  "x_refsource_BUGTRAQ",
                  "x_transferred"
                ],
                "url": "https://seclists.org/bugtraq/2019/Jun/8"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "http://packetstormsecurity.com/files/153225/Blipcare-Clear-Text-Communication-Memory-Corruption.html"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://github.com/ethanhunnt/IoT_vulnerabilities/blob/master/Blipcare_sec_issues.pdf"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "datePublic": "2019-06-07T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "It was discovered as a part of the research on IoT devices in the most recent firmware for Blipcare device that the device allows to connect to web management interface on a non-SSL connection using plain text HTTP protocol. The user uses the web management interface of the device to provide the user\u0027s Wi-Fi credentials so that the device can connect to it and have Internet access. This device acts as a Wireless Blood pressure monitor and is used to measure blood pressure levels of a person. This allows an attacker who is connected to the Blipcare\u0027s device wireless network to easily sniff these values using a MITM attack."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2019-07-02T20:33:34.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "name": "20190609 Newly releases IoT security issues",
              "tags": [
                "mailing-list",
                "x_refsource_BUGTRAQ"
              ],
              "url": "https://seclists.org/bugtraq/2019/Jun/8"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "http://packetstormsecurity.com/files/153225/Blipcare-Clear-Text-Communication-Memory-Corruption.html"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://github.com/ethanhunnt/IoT_vulnerabilities/blob/master/Blipcare_sec_issues.pdf"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cve@mitre.org",
              "ID": "CVE-2017-11578",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "It was discovered as a part of the research on IoT devices in the most recent firmware for Blipcare device that the device allows to connect to web management interface on a non-SSL connection using plain text HTTP protocol. The user uses the web management interface of the device to provide the user\u0027s Wi-Fi credentials so that the device can connect to it and have Internet access. This device acts as a Wireless Blood pressure monitor and is used to measure blood pressure levels of a person. This allows an attacker who is connected to the Blipcare\u0027s device wireless network to easily sniff these values using a MITM attack."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "20190609 Newly releases IoT security issues",
                  "refsource": "BUGTRAQ",
                  "url": "https://seclists.org/bugtraq/2019/Jun/8"
                },
                {
                  "name": "http://packetstormsecurity.com/files/153225/Blipcare-Clear-Text-Communication-Memory-Corruption.html",
                  "refsource": "MISC",
                  "url": "http://packetstormsecurity.com/files/153225/Blipcare-Clear-Text-Communication-Memory-Corruption.html"
                },
                {
                  "name": "https://github.com/ethanhunnt/IoT_vulnerabilities/blob/master/Blipcare_sec_issues.pdf",
                  "refsource": "MISC",
                  "url": "https://github.com/ethanhunnt/IoT_vulnerabilities/blob/master/Blipcare_sec_issues.pdf"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2017-11578",
        "datePublished": "2019-07-02T20:33:14.000Z",
        "dateReserved": "2017-07-23T00:00:00.000Z",
        "dateUpdated": "2024-08-05T18:12:40.629Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }