Search

Find a vulnerability

Search criteria

    2 vulnerabilities found for uFLOG5 by ABB

    CVE-2022-0902 (GCVE-0-2022-0902)

    Vulnerability from nvd – Published: 2022-07-21 15:34 – Updated: 2024-09-17 02:00
    VLAI
    Title
    ABB Flow Computer and Remote Controllers Path Traversal Vulnerability in Totalflow TCP protocol can lead to root access
    Summary
    Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal'), Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability in flow computer and remote controller products of ABB ( RMC-100 (Standard), RMC-100-LITE, XIO, XFCG5 , XRCG5 , uFLOG5 , UDC) allows an attacker who successfully exploited this vulnerability could insert and run arbitrary code in an affected system node.
    CWE
    • CWE-22 - Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
    • CWE-77 - Improper Neutralization of Special Elements used in a Command ('Command Injection')
    Assigner
    ABB
    References
    Impacted products
    Vendor Product Version
    ABB RMC-100 (Standard) Affected: unspecified , < 2105457-037 (custom)
    Create a notification for this product.
    ABB RMC-100-LITE Affected: unspecified , < 2106229-011 (custom)
    Create a notification for this product.
    ABB XIO Affected: unspecified , < 2106198-008 (custom)
    Create a notification for this product.
    ABB XFCG5 Affected: unspecified , < 2105805-016 (custom)
    Create a notification for this product.
    ABB XRCG5 Affected: unspecified , < 2105864-016 (custom)
    Create a notification for this product.
    ABB uFLOG5 Affected: unspecified , < 2105298-024 (custom)
    Create a notification for this product.
    ABB UDC Affected: unspecified , < 2106177-007 (custom)
    Create a notification for this product.
    Date Public
    2022-07-14 00:00
    Credits
    ABB thanks Vera Mens at Claroty Research for helping to identify the vulnerabilities and protecting our customers.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T23:47:42.131Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://search.abb.com/library/Download.aspx?DocumentID=9AKK108467A0927\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch\u0026_ga"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "RMC-100 (Standard)",
              "vendor": "ABB",
              "versions": [
                {
                  "lessThan": "2105457-037",
                  "status": "affected",
                  "version": "unspecified",
                  "versionType": "custom"
                }
              ]
            },
            {
              "product": "RMC-100-LITE",
              "vendor": "ABB",
              "versions": [
                {
                  "lessThan": "2106229-011",
                  "status": "affected",
                  "version": "unspecified",
                  "versionType": "custom"
                }
              ]
            },
            {
              "product": "XIO",
              "vendor": "ABB",
              "versions": [
                {
                  "lessThan": "2106198-008",
                  "status": "affected",
                  "version": "unspecified",
                  "versionType": "custom"
                }
              ]
            },
            {
              "product": "XFCG5",
              "vendor": "ABB",
              "versions": [
                {
                  "lessThan": "2105805-016",
                  "status": "affected",
                  "version": "unspecified",
                  "versionType": "custom"
                }
              ]
            },
            {
              "product": "XRCG5",
              "vendor": "ABB",
              "versions": [
                {
                  "lessThan": "2105864-016",
                  "status": "affected",
                  "version": "unspecified",
                  "versionType": "custom"
                }
              ]
            },
            {
              "product": "uFLOG5",
              "vendor": "ABB",
              "versions": [
                {
                  "lessThan": "2105298-024",
                  "status": "affected",
                  "version": "unspecified",
                  "versionType": "custom"
                }
              ]
            },
            {
              "product": "UDC",
              "vendor": "ABB",
              "versions": [
                {
                  "lessThan": "2106177-007",
                  "status": "affected",
                  "version": "unspecified",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "value": "ABB thanks Vera Mens at Claroty Research for helping to identify the vulnerabilities and protecting our customers."
            }
          ],
          "datePublic": "2022-07-14T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027), Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027) vulnerability in flow computer and remote controller products of ABB ( RMC-100 (Standard), RMC-100-LITE, XIO, XFCG5 , XRCG5 , uFLOG5 , UDC) allows an attacker who successfully exploited this vulnerability could insert and run arbitrary code in an affected system node."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "HIGH",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 8.1,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-22",
                  "description": "CWE-22 Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-77",
                  "description": "CWE-77 Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2022-07-21T15:34:49.000Z",
            "orgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
            "shortName": "ABB"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://search.abb.com/library/Download.aspx?DocumentID=9AKK108467A0927\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch\u0026_ga"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": "ABB Flow Computer and Remote Controllers Path Traversal Vulnerability in Totalflow TCP protocol can lead to root access",
          "x_generator": {
            "engine": "Vulnogram 0.0.9"
          },
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cybersecurity@ch.abb.com",
              "DATE_PUBLIC": "2022-07-14T06:51:00.000Z",
              "ID": "CVE-2022-0902",
              "STATE": "PUBLIC",
              "TITLE": "ABB Flow Computer and Remote Controllers Path Traversal Vulnerability in Totalflow TCP protocol can lead to root access"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "RMC-100 (Standard)",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003c",
                                "version_value": "2105457-037"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "RMC-100-LITE",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003c",
                                "version_value": "2106229-011"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "XIO",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003c",
                                "version_value": "2106198-008"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "XFCG5",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003c",
                                "version_value": "2105805-016"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "XRCG5",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003c",
                                "version_value": "2105864-016"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "uFLOG5",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003c",
                                "version_value": "2105298-024"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "UDC",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003c",
                                "version_value": "2106177-007"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "ABB"
                  }
                ]
              }
            },
            "credit": [
              {
                "lang": "eng",
                "value": "ABB thanks Vera Mens at Claroty Research for helping to identify the vulnerabilities and protecting our customers."
              }
            ],
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027), Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027) vulnerability in flow computer and remote controller products of ABB ( RMC-100 (Standard), RMC-100-LITE, XIO, XFCG5 , XRCG5 , uFLOG5 , UDC) allows an attacker who successfully exploited this vulnerability could insert and run arbitrary code in an affected system node."
                }
              ]
            },
            "generator": {
              "engine": "Vulnogram 0.0.9"
            },
            "impact": {
              "cvss": {
                "attackComplexity": "HIGH",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 8.1,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              }
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-22 Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)"
                    }
                  ]
                },
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-77 Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://search.abb.com/library/Download.aspx?DocumentID=9AKK108467A0927\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch\u0026_ga",
                  "refsource": "MISC",
                  "url": "https://search.abb.com/library/Download.aspx?DocumentID=9AKK108467A0927\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch\u0026_ga"
                }
              ]
            },
            "source": {
              "discovery": "UNKNOWN"
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
        "assignerShortName": "ABB",
        "cveId": "CVE-2022-0902",
        "datePublished": "2022-07-21T15:34:49.705Z",
        "dateReserved": "2022-03-09T00:00:00.000Z",
        "dateUpdated": "2024-09-17T02:00:38.883Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2022-0902 (GCVE-0-2022-0902)

    Vulnerability from cvelistv5 – Published: 2022-07-21 15:34 – Updated: 2024-09-17 02:00
    VLAI
    Title
    ABB Flow Computer and Remote Controllers Path Traversal Vulnerability in Totalflow TCP protocol can lead to root access
    Summary
    Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal'), Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability in flow computer and remote controller products of ABB ( RMC-100 (Standard), RMC-100-LITE, XIO, XFCG5 , XRCG5 , uFLOG5 , UDC) allows an attacker who successfully exploited this vulnerability could insert and run arbitrary code in an affected system node.
    CWE
    • CWE-22 - Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
    • CWE-77 - Improper Neutralization of Special Elements used in a Command ('Command Injection')
    Assigner
    ABB
    References
    Impacted products
    Vendor Product Version
    ABB RMC-100 (Standard) Affected: unspecified , < 2105457-037 (custom)
    Create a notification for this product.
    ABB RMC-100-LITE Affected: unspecified , < 2106229-011 (custom)
    Create a notification for this product.
    ABB XIO Affected: unspecified , < 2106198-008 (custom)
    Create a notification for this product.
    ABB XFCG5 Affected: unspecified , < 2105805-016 (custom)
    Create a notification for this product.
    ABB XRCG5 Affected: unspecified , < 2105864-016 (custom)
    Create a notification for this product.
    ABB uFLOG5 Affected: unspecified , < 2105298-024 (custom)
    Create a notification for this product.
    ABB UDC Affected: unspecified , < 2106177-007 (custom)
    Create a notification for this product.
    Date Public
    2022-07-14 00:00
    Credits
    ABB thanks Vera Mens at Claroty Research for helping to identify the vulnerabilities and protecting our customers.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T23:47:42.131Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://search.abb.com/library/Download.aspx?DocumentID=9AKK108467A0927\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch\u0026_ga"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "RMC-100 (Standard)",
              "vendor": "ABB",
              "versions": [
                {
                  "lessThan": "2105457-037",
                  "status": "affected",
                  "version": "unspecified",
                  "versionType": "custom"
                }
              ]
            },
            {
              "product": "RMC-100-LITE",
              "vendor": "ABB",
              "versions": [
                {
                  "lessThan": "2106229-011",
                  "status": "affected",
                  "version": "unspecified",
                  "versionType": "custom"
                }
              ]
            },
            {
              "product": "XIO",
              "vendor": "ABB",
              "versions": [
                {
                  "lessThan": "2106198-008",
                  "status": "affected",
                  "version": "unspecified",
                  "versionType": "custom"
                }
              ]
            },
            {
              "product": "XFCG5",
              "vendor": "ABB",
              "versions": [
                {
                  "lessThan": "2105805-016",
                  "status": "affected",
                  "version": "unspecified",
                  "versionType": "custom"
                }
              ]
            },
            {
              "product": "XRCG5",
              "vendor": "ABB",
              "versions": [
                {
                  "lessThan": "2105864-016",
                  "status": "affected",
                  "version": "unspecified",
                  "versionType": "custom"
                }
              ]
            },
            {
              "product": "uFLOG5",
              "vendor": "ABB",
              "versions": [
                {
                  "lessThan": "2105298-024",
                  "status": "affected",
                  "version": "unspecified",
                  "versionType": "custom"
                }
              ]
            },
            {
              "product": "UDC",
              "vendor": "ABB",
              "versions": [
                {
                  "lessThan": "2106177-007",
                  "status": "affected",
                  "version": "unspecified",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "value": "ABB thanks Vera Mens at Claroty Research for helping to identify the vulnerabilities and protecting our customers."
            }
          ],
          "datePublic": "2022-07-14T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027), Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027) vulnerability in flow computer and remote controller products of ABB ( RMC-100 (Standard), RMC-100-LITE, XIO, XFCG5 , XRCG5 , uFLOG5 , UDC) allows an attacker who successfully exploited this vulnerability could insert and run arbitrary code in an affected system node."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "HIGH",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 8.1,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-22",
                  "description": "CWE-22 Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-77",
                  "description": "CWE-77 Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2022-07-21T15:34:49.000Z",
            "orgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
            "shortName": "ABB"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://search.abb.com/library/Download.aspx?DocumentID=9AKK108467A0927\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch\u0026_ga"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": "ABB Flow Computer and Remote Controllers Path Traversal Vulnerability in Totalflow TCP protocol can lead to root access",
          "x_generator": {
            "engine": "Vulnogram 0.0.9"
          },
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cybersecurity@ch.abb.com",
              "DATE_PUBLIC": "2022-07-14T06:51:00.000Z",
              "ID": "CVE-2022-0902",
              "STATE": "PUBLIC",
              "TITLE": "ABB Flow Computer and Remote Controllers Path Traversal Vulnerability in Totalflow TCP protocol can lead to root access"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "RMC-100 (Standard)",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003c",
                                "version_value": "2105457-037"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "RMC-100-LITE",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003c",
                                "version_value": "2106229-011"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "XIO",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003c",
                                "version_value": "2106198-008"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "XFCG5",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003c",
                                "version_value": "2105805-016"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "XRCG5",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003c",
                                "version_value": "2105864-016"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "uFLOG5",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003c",
                                "version_value": "2105298-024"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "UDC",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003c",
                                "version_value": "2106177-007"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "ABB"
                  }
                ]
              }
            },
            "credit": [
              {
                "lang": "eng",
                "value": "ABB thanks Vera Mens at Claroty Research for helping to identify the vulnerabilities and protecting our customers."
              }
            ],
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027), Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027) vulnerability in flow computer and remote controller products of ABB ( RMC-100 (Standard), RMC-100-LITE, XIO, XFCG5 , XRCG5 , uFLOG5 , UDC) allows an attacker who successfully exploited this vulnerability could insert and run arbitrary code in an affected system node."
                }
              ]
            },
            "generator": {
              "engine": "Vulnogram 0.0.9"
            },
            "impact": {
              "cvss": {
                "attackComplexity": "HIGH",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 8.1,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              }
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-22 Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)"
                    }
                  ]
                },
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-77 Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://search.abb.com/library/Download.aspx?DocumentID=9AKK108467A0927\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch\u0026_ga",
                  "refsource": "MISC",
                  "url": "https://search.abb.com/library/Download.aspx?DocumentID=9AKK108467A0927\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch\u0026_ga"
                }
              ]
            },
            "source": {
              "discovery": "UNKNOWN"
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
        "assignerShortName": "ABB",
        "cveId": "CVE-2022-0902",
        "datePublished": "2022-07-21T15:34:49.705Z",
        "dateReserved": "2022-03-09T00:00:00.000Z",
        "dateUpdated": "2024-09-17T02:00:38.883Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }