Search criteria
8 vulnerabilities found for thinkcentre_m70a_gen_2_firmware by lenovo
CVE-2022-40136 (GCVE-0-2022-40136)
Vulnerability from nvd – Published: 2023-01-30 21:20 – Updated: 2025-03-27 15:25
VLAI?
Summary
An information leak vulnerability in SMI Handler used to configure platform settings over WMI in some Lenovo models may allow an attacker with local access and elevated privileges to read SMM memory.
Severity ?
4.4 (Medium)
CWE
- CWE-125 - Out-of-bounds Read
Assigner
References
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T12:14:39.820Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://support.lenovo.com/us/en/product_security/LEN-94953"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2022-40136",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-03-27T15:24:54.142774Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-03-27T15:25:10.981Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "BIOS",
"vendor": "Lenovo",
"versions": [
{
"status": "affected",
"version": "various"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "An information leak vulnerability in SMI Handler used to configure platform settings over WMI in some Lenovo models may allow an attacker with local access and elevated privileges to read SMM memory."
}
],
"value": "An information leak vulnerability in SMI Handler used to configure platform settings over WMI in some Lenovo models may allow an attacker with local access and elevated privileges to read SMM memory."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "NONE",
"baseScore": 4.4,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-125",
"description": "CWE-125 Out-of-bounds Read",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-01-30T21:20:45.280Z",
"orgId": "da227ddf-6e25-4b41-b023-0f976dcaca4b",
"shortName": "lenovo"
},
"references": [
{
"url": "https://support.lenovo.com/us/en/product_security/LEN-94953"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Update system firmware to the version (or newer) indicated for your model in the Product Impact section of LEN-94953."
}
],
"value": "Update system firmware to the version (or newer) indicated for your model in the Product Impact section of LEN-94953."
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "da227ddf-6e25-4b41-b023-0f976dcaca4b",
"assignerShortName": "lenovo",
"cveId": "CVE-2022-40136",
"datePublished": "2023-01-30T21:20:45.280Z",
"dateReserved": "2022-09-06T15:43:50.236Z",
"dateUpdated": "2025-03-27T15:25:10.981Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-40135 (GCVE-0-2022-40135)
Vulnerability from nvd – Published: 2023-01-30 21:20 – Updated: 2025-03-27 15:26
VLAI?
Summary
An information leak vulnerability in the Smart USB Protection SMI Handler in some Lenovo models may allow an attacker with local access and elevated privileges to read SMM memory.
Severity ?
4.4 (Medium)
CWE
- CWE-125 - Out-of-bounds Read
Assigner
References
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T12:14:39.736Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://support.lenovo.com/us/en/product_security/LEN-94953"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2022-40135",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-03-27T15:25:43.013586Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-03-27T15:26:04.196Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "BIOS",
"vendor": "Lenovo",
"versions": [
{
"status": "affected",
"version": "various"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "An information leak vulnerability in the Smart USB Protection SMI Handler in some Lenovo models may allow an attacker with local access and elevated privileges to read SMM memory."
}
],
"value": "An information leak vulnerability in the Smart USB Protection SMI Handler in some Lenovo models may allow an attacker with local access and elevated privileges to read SMM memory."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "NONE",
"baseScore": 4.4,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-125",
"description": "CWE-125 Out-of-bounds Read",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-01-30T21:20:33.347Z",
"orgId": "da227ddf-6e25-4b41-b023-0f976dcaca4b",
"shortName": "lenovo"
},
"references": [
{
"url": "https://support.lenovo.com/us/en/product_security/LEN-94953"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Update system firmware to the version (or newer) indicated for your model in the Product Impact section of LEN-94953."
}
],
"value": "Update system firmware to the version (or newer) indicated for your model in the Product Impact section of LEN-94953."
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "da227ddf-6e25-4b41-b023-0f976dcaca4b",
"assignerShortName": "lenovo",
"cveId": "CVE-2022-40135",
"datePublished": "2023-01-30T21:20:33.347Z",
"dateReserved": "2022-09-06T15:43:50.236Z",
"dateUpdated": "2025-03-27T15:26:04.196Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-40134 (GCVE-0-2022-40134)
Vulnerability from nvd – Published: 2023-01-30 21:20 – Updated: 2025-03-27 15:26
VLAI?
Summary
An information leak vulnerability in the SMI Set BIOS Password SMI Handler in some Lenovo models may allow an attacker with local access and elevated privileges to read SMM memory.
Severity ?
4.4 (Medium)
CWE
- CWE-125 - Out-of-bounds Read
Assigner
References
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T12:14:39.959Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://support.lenovo.com/us/en/product_security/LEN-94953"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2022-40134",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-03-27T15:26:39.063546Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-03-27T15:26:52.831Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "BIOS",
"vendor": "Lenovo",
"versions": [
{
"status": "affected",
"version": "various"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "An information leak vulnerability in the SMI Set BIOS Password SMI Handler in some Lenovo models may allow an attacker with local access and elevated privileges to read SMM memory."
}
],
"value": "An information leak vulnerability in the SMI Set BIOS Password SMI Handler in some Lenovo models may allow an attacker with local access and elevated privileges to read SMM memory."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "NONE",
"baseScore": 4.4,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-125",
"description": "CWE-125 Out-of-bounds Read",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-01-30T21:20:25.236Z",
"orgId": "da227ddf-6e25-4b41-b023-0f976dcaca4b",
"shortName": "lenovo"
},
"references": [
{
"url": "https://support.lenovo.com/us/en/product_security/LEN-94953"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Update system firmware to the version (or newer) indicated for your model in the Product Impact section of LEN-94953."
}
],
"value": "Update system firmware to the version (or newer) indicated for your model in the Product Impact section of LEN-94953."
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "da227ddf-6e25-4b41-b023-0f976dcaca4b",
"assignerShortName": "lenovo",
"cveId": "CVE-2022-40134",
"datePublished": "2023-01-30T21:20:25.236Z",
"dateReserved": "2022-09-06T15:43:50.235Z",
"dateUpdated": "2025-03-27T15:26:52.831Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-3519 (GCVE-0-2021-3519)
Vulnerability from nvd – Published: 2021-11-12 22:05 – Updated: 2024-08-03 17:01
VLAI?
Summary
A vulnerability was reported in some Lenovo Desktop models that could allow unauthorized access to the boot menu, when the "BIOS Password At Boot Device List" BIOS setting is Yes.
Severity ?
6.4 (Medium)
CWE
- CWE-287 - Improper Authentication
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Lenovo | Desktop BIOS |
Affected:
various
|
Credits
Lenovo thanks Pawel Urbanek for reporting this issue.
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T17:01:07.319Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://support.lenovo.com/us/en/product_security/LEN-67440"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Desktop BIOS",
"vendor": "Lenovo",
"versions": [
{
"status": "affected",
"version": "various"
}
]
}
],
"credits": [
{
"lang": "en",
"value": "Lenovo thanks Pawel Urbanek for reporting this issue."
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability was reported in some Lenovo Desktop models that could allow unauthorized access to the boot menu, when the \"BIOS Password At Boot Device List\" BIOS setting is Yes."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "PHYSICAL",
"availabilityImpact": "HIGH",
"baseScore": 6.4,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:L/A:H",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-287",
"description": "CWE-287 Improper Authentication",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-11-12T22:05:29",
"orgId": "da227ddf-6e25-4b41-b023-0f976dcaca4b",
"shortName": "lenovo"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://support.lenovo.com/us/en/product_security/LEN-67440"
}
],
"solutions": [
{
"lang": "en",
"value": "Update system firmware to the version (or newer) indicated for your model in the Product Impact section of LEN-67440."
}
],
"source": {
"advisory": "LEN-67440",
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.0.9"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "psirt@lenovo.com",
"ID": "CVE-2021-3519",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Desktop BIOS",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "various"
}
]
}
}
]
},
"vendor_name": "Lenovo"
}
]
}
},
"credit": [
{
"lang": "eng",
"value": "Lenovo thanks Pawel Urbanek for reporting this issue."
}
],
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A vulnerability was reported in some Lenovo Desktop models that could allow unauthorized access to the boot menu, when the \"BIOS Password At Boot Device List\" BIOS setting is Yes."
}
]
},
"generator": {
"engine": "Vulnogram 0.0.9"
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "PHYSICAL",
"availabilityImpact": "HIGH",
"baseScore": 6.4,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:L/A:H",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-287 Improper Authentication"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://support.lenovo.com/us/en/product_security/LEN-67440",
"refsource": "MISC",
"url": "https://support.lenovo.com/us/en/product_security/LEN-67440"
}
]
},
"solution": [
{
"lang": "en",
"value": "Update system firmware to the version (or newer) indicated for your model in the Product Impact section of LEN-67440."
}
],
"source": {
"advisory": "LEN-67440",
"discovery": "UNKNOWN"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "da227ddf-6e25-4b41-b023-0f976dcaca4b",
"assignerShortName": "lenovo",
"cveId": "CVE-2021-3519",
"datePublished": "2021-11-12T22:05:29",
"dateReserved": "2021-04-27T00:00:00",
"dateUpdated": "2024-08-03T17:01:07.319Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-40136 (GCVE-0-2022-40136)
Vulnerability from cvelistv5 – Published: 2023-01-30 21:20 – Updated: 2025-03-27 15:25
VLAI?
Summary
An information leak vulnerability in SMI Handler used to configure platform settings over WMI in some Lenovo models may allow an attacker with local access and elevated privileges to read SMM memory.
Severity ?
4.4 (Medium)
CWE
- CWE-125 - Out-of-bounds Read
Assigner
References
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T12:14:39.820Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://support.lenovo.com/us/en/product_security/LEN-94953"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2022-40136",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-03-27T15:24:54.142774Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-03-27T15:25:10.981Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "BIOS",
"vendor": "Lenovo",
"versions": [
{
"status": "affected",
"version": "various"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "An information leak vulnerability in SMI Handler used to configure platform settings over WMI in some Lenovo models may allow an attacker with local access and elevated privileges to read SMM memory."
}
],
"value": "An information leak vulnerability in SMI Handler used to configure platform settings over WMI in some Lenovo models may allow an attacker with local access and elevated privileges to read SMM memory."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "NONE",
"baseScore": 4.4,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-125",
"description": "CWE-125 Out-of-bounds Read",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-01-30T21:20:45.280Z",
"orgId": "da227ddf-6e25-4b41-b023-0f976dcaca4b",
"shortName": "lenovo"
},
"references": [
{
"url": "https://support.lenovo.com/us/en/product_security/LEN-94953"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Update system firmware to the version (or newer) indicated for your model in the Product Impact section of LEN-94953."
}
],
"value": "Update system firmware to the version (or newer) indicated for your model in the Product Impact section of LEN-94953."
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "da227ddf-6e25-4b41-b023-0f976dcaca4b",
"assignerShortName": "lenovo",
"cveId": "CVE-2022-40136",
"datePublished": "2023-01-30T21:20:45.280Z",
"dateReserved": "2022-09-06T15:43:50.236Z",
"dateUpdated": "2025-03-27T15:25:10.981Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-40135 (GCVE-0-2022-40135)
Vulnerability from cvelistv5 – Published: 2023-01-30 21:20 – Updated: 2025-03-27 15:26
VLAI?
Summary
An information leak vulnerability in the Smart USB Protection SMI Handler in some Lenovo models may allow an attacker with local access and elevated privileges to read SMM memory.
Severity ?
4.4 (Medium)
CWE
- CWE-125 - Out-of-bounds Read
Assigner
References
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T12:14:39.736Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://support.lenovo.com/us/en/product_security/LEN-94953"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2022-40135",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-03-27T15:25:43.013586Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-03-27T15:26:04.196Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "BIOS",
"vendor": "Lenovo",
"versions": [
{
"status": "affected",
"version": "various"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "An information leak vulnerability in the Smart USB Protection SMI Handler in some Lenovo models may allow an attacker with local access and elevated privileges to read SMM memory."
}
],
"value": "An information leak vulnerability in the Smart USB Protection SMI Handler in some Lenovo models may allow an attacker with local access and elevated privileges to read SMM memory."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "NONE",
"baseScore": 4.4,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-125",
"description": "CWE-125 Out-of-bounds Read",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-01-30T21:20:33.347Z",
"orgId": "da227ddf-6e25-4b41-b023-0f976dcaca4b",
"shortName": "lenovo"
},
"references": [
{
"url": "https://support.lenovo.com/us/en/product_security/LEN-94953"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Update system firmware to the version (or newer) indicated for your model in the Product Impact section of LEN-94953."
}
],
"value": "Update system firmware to the version (or newer) indicated for your model in the Product Impact section of LEN-94953."
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "da227ddf-6e25-4b41-b023-0f976dcaca4b",
"assignerShortName": "lenovo",
"cveId": "CVE-2022-40135",
"datePublished": "2023-01-30T21:20:33.347Z",
"dateReserved": "2022-09-06T15:43:50.236Z",
"dateUpdated": "2025-03-27T15:26:04.196Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-40134 (GCVE-0-2022-40134)
Vulnerability from cvelistv5 – Published: 2023-01-30 21:20 – Updated: 2025-03-27 15:26
VLAI?
Summary
An information leak vulnerability in the SMI Set BIOS Password SMI Handler in some Lenovo models may allow an attacker with local access and elevated privileges to read SMM memory.
Severity ?
4.4 (Medium)
CWE
- CWE-125 - Out-of-bounds Read
Assigner
References
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T12:14:39.959Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://support.lenovo.com/us/en/product_security/LEN-94953"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2022-40134",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-03-27T15:26:39.063546Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-03-27T15:26:52.831Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "BIOS",
"vendor": "Lenovo",
"versions": [
{
"status": "affected",
"version": "various"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "An information leak vulnerability in the SMI Set BIOS Password SMI Handler in some Lenovo models may allow an attacker with local access and elevated privileges to read SMM memory."
}
],
"value": "An information leak vulnerability in the SMI Set BIOS Password SMI Handler in some Lenovo models may allow an attacker with local access and elevated privileges to read SMM memory."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "NONE",
"baseScore": 4.4,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-125",
"description": "CWE-125 Out-of-bounds Read",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-01-30T21:20:25.236Z",
"orgId": "da227ddf-6e25-4b41-b023-0f976dcaca4b",
"shortName": "lenovo"
},
"references": [
{
"url": "https://support.lenovo.com/us/en/product_security/LEN-94953"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Update system firmware to the version (or newer) indicated for your model in the Product Impact section of LEN-94953."
}
],
"value": "Update system firmware to the version (or newer) indicated for your model in the Product Impact section of LEN-94953."
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "da227ddf-6e25-4b41-b023-0f976dcaca4b",
"assignerShortName": "lenovo",
"cveId": "CVE-2022-40134",
"datePublished": "2023-01-30T21:20:25.236Z",
"dateReserved": "2022-09-06T15:43:50.235Z",
"dateUpdated": "2025-03-27T15:26:52.831Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-3519 (GCVE-0-2021-3519)
Vulnerability from cvelistv5 – Published: 2021-11-12 22:05 – Updated: 2024-08-03 17:01
VLAI?
Summary
A vulnerability was reported in some Lenovo Desktop models that could allow unauthorized access to the boot menu, when the "BIOS Password At Boot Device List" BIOS setting is Yes.
Severity ?
6.4 (Medium)
CWE
- CWE-287 - Improper Authentication
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Lenovo | Desktop BIOS |
Affected:
various
|
Credits
Lenovo thanks Pawel Urbanek for reporting this issue.
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T17:01:07.319Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://support.lenovo.com/us/en/product_security/LEN-67440"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Desktop BIOS",
"vendor": "Lenovo",
"versions": [
{
"status": "affected",
"version": "various"
}
]
}
],
"credits": [
{
"lang": "en",
"value": "Lenovo thanks Pawel Urbanek for reporting this issue."
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability was reported in some Lenovo Desktop models that could allow unauthorized access to the boot menu, when the \"BIOS Password At Boot Device List\" BIOS setting is Yes."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "PHYSICAL",
"availabilityImpact": "HIGH",
"baseScore": 6.4,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:L/A:H",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-287",
"description": "CWE-287 Improper Authentication",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-11-12T22:05:29",
"orgId": "da227ddf-6e25-4b41-b023-0f976dcaca4b",
"shortName": "lenovo"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://support.lenovo.com/us/en/product_security/LEN-67440"
}
],
"solutions": [
{
"lang": "en",
"value": "Update system firmware to the version (or newer) indicated for your model in the Product Impact section of LEN-67440."
}
],
"source": {
"advisory": "LEN-67440",
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.0.9"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "psirt@lenovo.com",
"ID": "CVE-2021-3519",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Desktop BIOS",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "various"
}
]
}
}
]
},
"vendor_name": "Lenovo"
}
]
}
},
"credit": [
{
"lang": "eng",
"value": "Lenovo thanks Pawel Urbanek for reporting this issue."
}
],
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A vulnerability was reported in some Lenovo Desktop models that could allow unauthorized access to the boot menu, when the \"BIOS Password At Boot Device List\" BIOS setting is Yes."
}
]
},
"generator": {
"engine": "Vulnogram 0.0.9"
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "PHYSICAL",
"availabilityImpact": "HIGH",
"baseScore": 6.4,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:L/A:H",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-287 Improper Authentication"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://support.lenovo.com/us/en/product_security/LEN-67440",
"refsource": "MISC",
"url": "https://support.lenovo.com/us/en/product_security/LEN-67440"
}
]
},
"solution": [
{
"lang": "en",
"value": "Update system firmware to the version (or newer) indicated for your model in the Product Impact section of LEN-67440."
}
],
"source": {
"advisory": "LEN-67440",
"discovery": "UNKNOWN"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "da227ddf-6e25-4b41-b023-0f976dcaca4b",
"assignerShortName": "lenovo",
"cveId": "CVE-2021-3519",
"datePublished": "2021-11-12T22:05:29",
"dateReserved": "2021-04-27T00:00:00",
"dateUpdated": "2024-08-03T17:01:07.319Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}