Search

Find a vulnerability

Search criteria

    22 vulnerabilities found for thinkcentre_m70a_firmware by lenovo

    CVE-2023-45079 (GCVE-0-2023-45079)

    Vulnerability from nvd – Published: 2023-11-08 22:32 – Updated: 2024-09-04 17:43
    VLAI
    Summary
    A memory leakage vulnerability was reported in the NvmramSmm SMM driver that may allow a local attacker with elevated privileges to write to NVRAM variables.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    Assigner
    Impacted products
    Vendor Product Version
    Lenovo BIOS Affected: various
    Create a notification for this product.
    lenovo bios Affected: various
        cpe:2.3:o:lenovo:bios:-:*:*:*:*:*:*:*
    Create a notification for this product.
    Credits
    Lenovo thanks Souhardya Sardar of Cyberstanc for reporting this issue.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T20:14:19.032Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://support.lenovo.com/us/en/product_security/LEN-141775"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "affected": [
              {
                "cpes": [
                  "cpe:2.3:o:lenovo:bios:-:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "bios",
                "vendor": "lenovo",
                "versions": [
                  {
                    "status": "affected",
                    "version": "various"
                  }
                ]
              }
            ],
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2023-45079",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-09-04T17:42:45.727166Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-09-04T17:43:46.981Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "BIOS",
              "vendor": "Lenovo",
              "versions": [
                {
                  "status": "affected",
                  "version": "various"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Lenovo thanks Souhardya Sardar of Cyberstanc for reporting this issue."
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "A memory leakage vulnerability was reported in the NvmramSmm SMM driver that may allow a local attacker with elevated privileges to write to NVRAM variables. \u003cbr\u003e\u003cbr\u003e"
                }
              ],
              "value": "A memory leakage vulnerability was reported in the NvmramSmm SMM driver that may allow a local attacker with elevated privileges to write to NVRAM variables. \n\n"
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "HIGH",
                "baseScore": 6.7,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "HIGH",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-125",
                  "description": "CWE-125 Out-of-bounds Read",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2023-11-08T22:32:37.592Z",
            "orgId": "da227ddf-6e25-4b41-b023-0f976dcaca4b",
            "shortName": "lenovo"
          },
          "references": [
            {
              "url": "https://support.lenovo.com/us/en/product_security/LEN-141775"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Update system firmware to the version (or newer) indicated for your model in the advisory: \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://support.lenovo.com/us/en/product_security/LEN-141775\"\u003ehttps://support.lenovo.com/us/en/product_security/LEN-141775\u003c/a\u003e"
                }
              ],
              "value": "Update system firmware to the version (or newer) indicated for your model in the advisory:  https://support.lenovo.com/us/en/product_security/LEN-141775 "
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "da227ddf-6e25-4b41-b023-0f976dcaca4b",
        "assignerShortName": "lenovo",
        "cveId": "CVE-2023-45079",
        "datePublished": "2023-11-08T22:32:37.592Z",
        "dateReserved": "2023-10-03T17:36:49.034Z",
        "dateUpdated": "2024-09-04T17:43:46.981Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2023-45078 (GCVE-0-2023-45078)

    Vulnerability from nvd – Published: 2023-11-08 22:30 – Updated: 2024-09-04 17:50
    VLAI
    Summary
    A memory leakage vulnerability was reported in the DustFilterAlertSmm SMM driver that may allow a local attacker with elevated privileges to write to NVRAM variables.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    Assigner
    Impacted products
    Vendor Product Version
    Lenovo BIOS Affected: various
    Create a notification for this product.
    lenovo bios Affected: various
        cpe:2.3:o:lenovo:bios:-:*:*:*:*:*:*:*
    Create a notification for this product.
    Credits
    Lenovo thanks Souhardya Sardar of Cyberstanc for reporting this issue.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T20:14:18.388Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://support.lenovo.com/us/en/product_security/LEN-141775"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "affected": [
              {
                "cpes": [
                  "cpe:2.3:o:lenovo:bios:-:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "bios",
                "vendor": "lenovo",
                "versions": [
                  {
                    "status": "affected",
                    "version": "various"
                  }
                ]
              }
            ],
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2023-45078",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-09-04T17:48:51.693243Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-09-04T17:50:14.651Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "BIOS",
              "vendor": "Lenovo",
              "versions": [
                {
                  "status": "affected",
                  "version": "various"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Lenovo thanks Souhardya Sardar of Cyberstanc for reporting this issue."
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "A memory leakage vulnerability was reported in the DustFilterAlertSmm SMM driver that may allow a local attacker with elevated privileges to write to NVRAM variables. "
                }
              ],
              "value": "A memory leakage vulnerability was reported in the DustFilterAlertSmm SMM driver that may allow a local attacker with elevated privileges to write to NVRAM variables. "
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "HIGH",
                "baseScore": 6.7,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "HIGH",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-125",
                  "description": "CWE-125 Out-of-bounds Read",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2023-11-08T22:30:49.077Z",
            "orgId": "da227ddf-6e25-4b41-b023-0f976dcaca4b",
            "shortName": "lenovo"
          },
          "references": [
            {
              "url": "https://support.lenovo.com/us/en/product_security/LEN-141775"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Update system firmware to the version (or newer) indicated for your model in the advisory: \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://support.lenovo.com/us/en/product_security/LEN-141775\"\u003ehttps://support.lenovo.com/us/en/product_security/LEN-141775\u003c/a\u003e"
                }
              ],
              "value": "Update system firmware to the version (or newer) indicated for your model in the advisory:  https://support.lenovo.com/us/en/product_security/LEN-141775 "
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "da227ddf-6e25-4b41-b023-0f976dcaca4b",
        "assignerShortName": "lenovo",
        "cveId": "CVE-2023-45078",
        "datePublished": "2023-11-08T22:30:49.077Z",
        "dateReserved": "2023-10-03T17:36:49.034Z",
        "dateUpdated": "2024-09-04T17:50:14.651Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2023-45077 (GCVE-0-2023-45077)

    Vulnerability from nvd – Published: 2023-11-08 22:30 – Updated: 2024-09-04 17:54
    VLAI
    Summary
    A memory leakage vulnerability was reported in the 534D0740 DXE driver that may allow a local attacker with elevated privileges to write to NVRAM variables.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    Assigner
    Impacted products
    Vendor Product Version
    Lenovo BIOS Affected: various
    Create a notification for this product.
    lenovo bios Affected: various
        cpe:2.3:o:lenovo:bios:-:*:*:*:*:*:*:*
    Create a notification for this product.
    Credits
    Lenovo thanks Souhardya Sardar of Cyberstanc for reporting this issue.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T20:14:19.032Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://support.lenovo.com/us/en/product_security/LEN-141775"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "affected": [
              {
                "cpes": [
                  "cpe:2.3:o:lenovo:bios:-:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "bios",
                "vendor": "lenovo",
                "versions": [
                  {
                    "status": "affected",
                    "version": "various"
                  }
                ]
              }
            ],
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2023-45077",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-09-04T17:52:03.826324Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-09-04T17:54:09.101Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "BIOS",
              "vendor": "Lenovo",
              "versions": [
                {
                  "status": "affected",
                  "version": "various"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Lenovo thanks Souhardya Sardar of Cyberstanc for reporting this issue."
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "A memory leakage vulnerability was reported in the 534D0740 DXE driver that may allow a local attacker with elevated privileges to write to NVRAM variables. "
                }
              ],
              "value": "A memory leakage vulnerability was reported in the 534D0740 DXE driver that may allow a local attacker with elevated privileges to write to NVRAM variables. "
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "HIGH",
                "baseScore": 6.7,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "HIGH",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-125",
                  "description": "CWE-125 Out-of-bounds Read",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2023-11-08T22:38:59.712Z",
            "orgId": "da227ddf-6e25-4b41-b023-0f976dcaca4b",
            "shortName": "lenovo"
          },
          "references": [
            {
              "url": "https://support.lenovo.com/us/en/product_security/LEN-141775"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Update system firmware to the version (or newer) indicated for your model in the advisory: \u003ca href=\"https://support.lenovo.com/us/en/product_security/LEN-141775\"\u003ehttps://support.lenovo.com/us/en/product_security/LEN-141775\u003c/a\u003e"
                }
              ],
              "value": "Update system firmware to the version (or newer) indicated for your model in the advisory:  https://support.lenovo.com/us/en/product_security/LEN-141775 "
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "da227ddf-6e25-4b41-b023-0f976dcaca4b",
        "assignerShortName": "lenovo",
        "cveId": "CVE-2023-45077",
        "datePublished": "2023-11-08T22:30:05.886Z",
        "dateReserved": "2023-10-03T17:36:49.034Z",
        "dateUpdated": "2024-09-04T17:54:09.101Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2023-45076 (GCVE-0-2023-45076)

    Vulnerability from nvd – Published: 2023-11-08 22:28 – Updated: 2024-09-04 17:56
    VLAI
    Summary
    A memory leakage vulnerability was reported in the 534D0140 DXE driver that may allow a local attacker with elevated privileges to write to NVRAM variables.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    Assigner
    Impacted products
    Vendor Product Version
    Lenovo BIOS Affected: various
    Create a notification for this product.
    lenovo bios Affected: various
        cpe:2.3:o:lenovo:bios:-:*:*:*:*:*:*:*
    Create a notification for this product.
    Credits
    Lenovo thanks Souhardya Sardar of Cyberstanc for reporting this issue.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T20:14:19.503Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://support.lenovo.com/us/en/product_security/LEN-141775"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "affected": [
              {
                "cpes": [
                  "cpe:2.3:o:lenovo:bios:-:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "bios",
                "vendor": "lenovo",
                "versions": [
                  {
                    "status": "affected",
                    "version": "various"
                  }
                ]
              }
            ],
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2023-45076",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-09-04T17:55:45.684582Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-09-04T17:56:30.453Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "BIOS",
              "vendor": "Lenovo",
              "versions": [
                {
                  "status": "affected",
                  "version": "various"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Lenovo thanks Souhardya Sardar of Cyberstanc for reporting this issue."
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "A memory leakage vulnerability was reported in the 534D0140 DXE driver that may allow a local attacker with elevated privileges to write to NVRAM variables.\u003cbr\u003e"
                }
              ],
              "value": "A memory leakage vulnerability was reported in the 534D0140 DXE driver that may allow a local attacker with elevated privileges to write to NVRAM variables.\n"
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "HIGH",
                "baseScore": 6.7,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "HIGH",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-125",
                  "description": "CWE-125 Out-of-bounds Read",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2023-11-08T22:28:20.459Z",
            "orgId": "da227ddf-6e25-4b41-b023-0f976dcaca4b",
            "shortName": "lenovo"
          },
          "references": [
            {
              "url": "https://support.lenovo.com/us/en/product_security/LEN-141775"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Update system firmware to the version (or newer) indicated for your model in the advisory: \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://support.lenovo.com/us/en/product_security/LEN-141775\"\u003ehttps://support.lenovo.com/us/en/product_security/LEN-141775\u003c/a\u003e"
                }
              ],
              "value": "Update system firmware to the version (or newer) indicated for your model in the advisory:  https://support.lenovo.com/us/en/product_security/LEN-141775 "
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "da227ddf-6e25-4b41-b023-0f976dcaca4b",
        "assignerShortName": "lenovo",
        "cveId": "CVE-2023-45076",
        "datePublished": "2023-11-08T22:28:20.459Z",
        "dateReserved": "2023-10-03T17:36:49.034Z",
        "dateUpdated": "2024-09-04T17:56:30.453Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2023-45075 (GCVE-0-2023-45075)

    Vulnerability from nvd – Published: 2023-11-08 22:27 – Updated: 2024-09-04 17:58
    VLAI
    Summary
    A memory leakage vulnerability was reported in the SWSMI_Shadow DXE driver that may allow a local attacker with elevated privileges to write to NVRAM variables.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    Assigner
    Impacted products
    Vendor Product Version
    Lenovo BIOS Affected: various
    Create a notification for this product.
    lenovo bios Affected: various
        cpe:2.3:o:lenovo:bios:-:*:*:*:*:*:*:*
    Create a notification for this product.
    Credits
    Lenovo thanks Souhardya Sardar of Cyberstanc for reporting this issue.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T20:14:19.819Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://support.lenovo.com/us/en/product_security/LEN-141775"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "affected": [
              {
                "cpes": [
                  "cpe:2.3:o:lenovo:bios:-:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "bios",
                "vendor": "lenovo",
                "versions": [
                  {
                    "status": "affected",
                    "version": "various"
                  }
                ]
              }
            ],
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2023-45075",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-09-04T17:57:18.522310Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-09-04T17:58:47.396Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "BIOS",
              "vendor": "Lenovo",
              "versions": [
                {
                  "status": "affected",
                  "version": "various"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Lenovo thanks Souhardya Sardar of Cyberstanc for reporting this issue."
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "A memory leakage vulnerability was reported in the SWSMI_Shadow DXE driver that may allow a local attacker with elevated privileges to write to NVRAM variables."
                }
              ],
              "value": "A memory leakage vulnerability was reported in the SWSMI_Shadow DXE driver that may allow a local attacker with elevated privileges to write to NVRAM variables."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "HIGH",
                "baseScore": 6.7,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "HIGH",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-125",
                  "description": "CWE-125 Out-of-bounds Read",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2023-11-08T22:27:32.659Z",
            "orgId": "da227ddf-6e25-4b41-b023-0f976dcaca4b",
            "shortName": "lenovo"
          },
          "references": [
            {
              "url": "https://support.lenovo.com/us/en/product_security/LEN-141775"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Update system firmware to the version (or newer) indicated for your model in the advisory: \u003ca href=\"https://support.lenovo.com/us/en/product_security/LEN-141775\"\u003ehttps://support.lenovo.com/us/en/product_security/LEN-141775\u003c/a\u003e"
                }
              ],
              "value": "Update system firmware to the version (or newer) indicated for your model in the advisory:  https://support.lenovo.com/us/en/product_security/LEN-141775 "
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "da227ddf-6e25-4b41-b023-0f976dcaca4b",
        "assignerShortName": "lenovo",
        "cveId": "CVE-2023-45075",
        "datePublished": "2023-11-08T22:27:32.659Z",
        "dateReserved": "2023-10-03T17:36:49.034Z",
        "dateUpdated": "2024-09-04T17:58:47.396Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2022-40136 (GCVE-0-2022-40136)

    Vulnerability from nvd – Published: 2023-01-30 21:20 – Updated: 2025-03-27 15:25
    VLAI
    Summary
    An information leak vulnerability in SMI Handler used to configure platform settings over WMI in some Lenovo models may allow an attacker with local access and elevated privileges to read SMM memory.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    Assigner
    Impacted products
    Vendor Product Version
    Lenovo BIOS Affected: various
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T12:14:39.820Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://support.lenovo.com/us/en/product_security/LEN-94953"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2022-40136",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-03-27T15:24:54.142774Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-03-27T15:25:10.981Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "BIOS",
              "vendor": "Lenovo",
              "versions": [
                {
                  "status": "affected",
                  "version": "various"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "An information leak vulnerability in SMI Handler used to configure platform settings over WMI in some Lenovo models may allow an attacker with local access and elevated privileges to read SMM memory."
                }
              ],
              "value": "An information leak vulnerability in SMI Handler used to configure platform settings over WMI in some Lenovo models may allow an attacker with local access and elevated privileges to read SMM memory."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "NONE",
                "baseScore": 4.4,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "NONE",
                "privilegesRequired": "HIGH",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:N/A:N",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-125",
                  "description": "CWE-125 Out-of-bounds Read",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2023-01-30T21:20:45.280Z",
            "orgId": "da227ddf-6e25-4b41-b023-0f976dcaca4b",
            "shortName": "lenovo"
          },
          "references": [
            {
              "url": "https://support.lenovo.com/us/en/product_security/LEN-94953"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Update system firmware to the version (or newer) indicated for your model in the Product Impact section of LEN-94953."
                }
              ],
              "value": "Update system firmware to the version (or newer) indicated for your model in the Product Impact section of LEN-94953."
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "da227ddf-6e25-4b41-b023-0f976dcaca4b",
        "assignerShortName": "lenovo",
        "cveId": "CVE-2022-40136",
        "datePublished": "2023-01-30T21:20:45.280Z",
        "dateReserved": "2022-09-06T15:43:50.236Z",
        "dateUpdated": "2025-03-27T15:25:10.981Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2022-40135 (GCVE-0-2022-40135)

    Vulnerability from nvd – Published: 2023-01-30 21:20 – Updated: 2025-03-27 15:26
    VLAI
    Summary
    An information leak vulnerability in the Smart USB Protection SMI Handler in some Lenovo models may allow an attacker with local access and elevated privileges to read SMM memory.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    Assigner
    Impacted products
    Vendor Product Version
    Lenovo BIOS Affected: various
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T12:14:39.736Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://support.lenovo.com/us/en/product_security/LEN-94953"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2022-40135",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-03-27T15:25:43.013586Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-03-27T15:26:04.196Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "BIOS",
              "vendor": "Lenovo",
              "versions": [
                {
                  "status": "affected",
                  "version": "various"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "An information leak vulnerability in the Smart USB Protection SMI Handler in some Lenovo models may allow an attacker with local access and elevated privileges to read SMM memory."
                }
              ],
              "value": "An information leak vulnerability in the Smart USB Protection SMI Handler in some Lenovo models may allow an attacker with local access and elevated privileges to read SMM memory."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "NONE",
                "baseScore": 4.4,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "NONE",
                "privilegesRequired": "HIGH",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:N/A:N",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-125",
                  "description": "CWE-125 Out-of-bounds Read",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2023-01-30T21:20:33.347Z",
            "orgId": "da227ddf-6e25-4b41-b023-0f976dcaca4b",
            "shortName": "lenovo"
          },
          "references": [
            {
              "url": "https://support.lenovo.com/us/en/product_security/LEN-94953"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Update system firmware to the version (or newer) indicated for your model in the Product Impact section of LEN-94953."
                }
              ],
              "value": "Update system firmware to the version (or newer) indicated for your model in the Product Impact section of LEN-94953."
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "da227ddf-6e25-4b41-b023-0f976dcaca4b",
        "assignerShortName": "lenovo",
        "cveId": "CVE-2022-40135",
        "datePublished": "2023-01-30T21:20:33.347Z",
        "dateReserved": "2022-09-06T15:43:50.236Z",
        "dateUpdated": "2025-03-27T15:26:04.196Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2022-40134 (GCVE-0-2022-40134)

    Vulnerability from nvd – Published: 2023-01-30 21:20 – Updated: 2025-03-27 15:26
    VLAI
    Summary
    An information leak vulnerability in the SMI Set BIOS Password SMI Handler in some Lenovo models may allow an attacker with local access and elevated privileges to read SMM memory.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    Assigner
    Impacted products
    Vendor Product Version
    Lenovo BIOS Affected: various
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T12:14:39.959Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://support.lenovo.com/us/en/product_security/LEN-94953"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2022-40134",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-03-27T15:26:39.063546Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-03-27T15:26:52.831Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "BIOS",
              "vendor": "Lenovo",
              "versions": [
                {
                  "status": "affected",
                  "version": "various"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "An information leak vulnerability in the SMI Set BIOS Password SMI Handler in some Lenovo models may allow an attacker with local access and elevated privileges to read SMM memory."
                }
              ],
              "value": "An information leak vulnerability in the SMI Set BIOS Password SMI Handler in some Lenovo models may allow an attacker with local access and elevated privileges to read SMM memory."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "NONE",
                "baseScore": 4.4,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "NONE",
                "privilegesRequired": "HIGH",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:N/A:N",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-125",
                  "description": "CWE-125 Out-of-bounds Read",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2023-01-30T21:20:25.236Z",
            "orgId": "da227ddf-6e25-4b41-b023-0f976dcaca4b",
            "shortName": "lenovo"
          },
          "references": [
            {
              "url": "https://support.lenovo.com/us/en/product_security/LEN-94953"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Update system firmware to the version (or newer) indicated for your model in the Product Impact section of LEN-94953."
                }
              ],
              "value": "Update system firmware to the version (or newer) indicated for your model in the Product Impact section of LEN-94953."
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "da227ddf-6e25-4b41-b023-0f976dcaca4b",
        "assignerShortName": "lenovo",
        "cveId": "CVE-2022-40134",
        "datePublished": "2023-01-30T21:20:25.236Z",
        "dateReserved": "2022-09-06T15:43:50.235Z",
        "dateUpdated": "2025-03-27T15:26:52.831Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2021-4211 (GCVE-0-2021-4211)

    Vulnerability from nvd – Published: 2022-04-22 20:30 – Updated: 2024-08-03 17:16
    VLAI
    Summary
    A potential vulnerability in the SMI callback function used in the SMBIOS event log driver in some Lenovo Desktop, ThinkStation, and ThinkEdge models may allow an attacker with local access and elevated privileges to execute arbitrary code.
    CWE
    • CWE-20 - Improper Input Validation
    Assigner
    References
    Impacted products
    Vendor Product Version
    Lenovo BIOS Affected: various
    Create a notification for this product.
    Credits
    Lenovo thanks Jiawei Yin(@yngweijw) and Menghao Li of IIE varas
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T17:16:04.358Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://support.lenovo.com/us/en/product_security/LEN-77639"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "BIOS",
              "vendor": "Lenovo",
              "versions": [
                {
                  "status": "affected",
                  "version": "various"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "value": "Lenovo thanks Jiawei Yin(@yngweijw) and Menghao Li of IIE varas"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A potential vulnerability in the SMI callback function used in the SMBIOS event log driver in some Lenovo Desktop, ThinkStation, and ThinkEdge models may allow an attacker with local access and elevated privileges to execute arbitrary code."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "HIGH",
                "baseScore": 6.7,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "HIGH",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-20",
                  "description": "CWE-20 Improper Input Validation",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2022-04-22T20:30:43.000Z",
            "orgId": "da227ddf-6e25-4b41-b023-0f976dcaca4b",
            "shortName": "lenovo"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://support.lenovo.com/us/en/product_security/LEN-77639"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "value": "Update system firmware to the version (or newer) indicated for your model in the Product Impact section in LEN-77639."
            }
          ],
          "source": {
            "advisory": "LEN-77639",
            "discovery": "UNKNOWN"
          },
          "x_generator": {
            "engine": "Vulnogram 0.0.9"
          },
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "psirt@lenovo.com",
              "ID": "CVE-2021-4211",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "BIOS",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "=",
                                "version_value": "various"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "Lenovo"
                  }
                ]
              }
            },
            "credit": [
              {
                "lang": "eng",
                "value": "Lenovo thanks Jiawei Yin(@yngweijw) and Menghao Li of IIE varas"
              }
            ],
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "A potential vulnerability in the SMI callback function used in the SMBIOS event log driver in some Lenovo Desktop, ThinkStation, and ThinkEdge models may allow an attacker with local access and elevated privileges to execute arbitrary code."
                }
              ]
            },
            "generator": {
              "engine": "Vulnogram 0.0.9"
            },
            "impact": {
              "cvss": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "HIGH",
                "baseScore": 6.7,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "HIGH",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              }
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-20 Improper Input Validation"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://support.lenovo.com/us/en/product_security/LEN-77639",
                  "refsource": "MISC",
                  "url": "https://support.lenovo.com/us/en/product_security/LEN-77639"
                }
              ]
            },
            "solution": [
              {
                "lang": "en",
                "value": "Update system firmware to the version (or newer) indicated for your model in the Product Impact section in LEN-77639."
              }
            ],
            "source": {
              "advisory": "LEN-77639",
              "discovery": "UNKNOWN"
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "da227ddf-6e25-4b41-b023-0f976dcaca4b",
        "assignerShortName": "lenovo",
        "cveId": "CVE-2021-4211",
        "datePublished": "2022-04-22T20:30:43.000Z",
        "dateReserved": "2022-01-24T00:00:00.000Z",
        "dateUpdated": "2024-08-03T17:16:04.358Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2021-4210 (GCVE-0-2021-4210)

    Vulnerability from nvd – Published: 2022-04-22 20:30 – Updated: 2024-08-03 17:16
    VLAI
    Summary
    A potential vulnerability in the SMI callback function used in the NVME driver in some Lenovo Desktop, ThinkStation, and ThinkEdge models may allow an attacker with local access and elevated privileges to execute arbitrary code.
    CWE
    • CWE-20 - Improper Input Validation
    Assigner
    References
    Impacted products
    Vendor Product Version
    Lenovo BIOS Affected: various
    Create a notification for this product.
    Credits
    Lenovo thanks Jiawei Yin(@yngweijw) and Menghao Li of IIE varas
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T17:16:04.261Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://support.lenovo.com/us/en/product_security/LEN-77639"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "BIOS",
              "vendor": "Lenovo",
              "versions": [
                {
                  "status": "affected",
                  "version": "various"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "value": "Lenovo thanks Jiawei Yin(@yngweijw) and Menghao Li of IIE varas"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A potential vulnerability in the SMI callback function used in the NVME driver in some Lenovo Desktop, ThinkStation, and ThinkEdge models may allow an attacker with local access and elevated privileges to execute arbitrary code."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "HIGH",
                "baseScore": 6.7,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "HIGH",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-20",
                  "description": "CWE-20 Improper Input Validation",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2022-04-22T20:30:41.000Z",
            "orgId": "da227ddf-6e25-4b41-b023-0f976dcaca4b",
            "shortName": "lenovo"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://support.lenovo.com/us/en/product_security/LEN-77639"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "value": "Update system firmware to the version (or newer) indicated for your model in the Product Impact section in LEN-77639."
            }
          ],
          "source": {
            "advisory": "LEN-77639",
            "discovery": "UNKNOWN"
          },
          "x_generator": {
            "engine": "Vulnogram 0.0.9"
          },
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "psirt@lenovo.com",
              "ID": "CVE-2021-4210",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "BIOS",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "=",
                                "version_value": "various"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "Lenovo"
                  }
                ]
              }
            },
            "credit": [
              {
                "lang": "eng",
                "value": "Lenovo thanks Jiawei Yin(@yngweijw) and Menghao Li of IIE varas"
              }
            ],
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "A potential vulnerability in the SMI callback function used in the NVME driver in some Lenovo Desktop, ThinkStation, and ThinkEdge models may allow an attacker with local access and elevated privileges to execute arbitrary code."
                }
              ]
            },
            "generator": {
              "engine": "Vulnogram 0.0.9"
            },
            "impact": {
              "cvss": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "HIGH",
                "baseScore": 6.7,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "HIGH",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              }
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-20 Improper Input Validation"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://support.lenovo.com/us/en/product_security/LEN-77639",
                  "refsource": "MISC",
                  "url": "https://support.lenovo.com/us/en/product_security/LEN-77639"
                }
              ]
            },
            "solution": [
              {
                "lang": "en",
                "value": "Update system firmware to the version (or newer) indicated for your model in the Product Impact section in LEN-77639."
              }
            ],
            "source": {
              "advisory": "LEN-77639",
              "discovery": "UNKNOWN"
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "da227ddf-6e25-4b41-b023-0f976dcaca4b",
        "assignerShortName": "lenovo",
        "cveId": "CVE-2021-4210",
        "datePublished": "2022-04-22T20:30:41.000Z",
        "dateReserved": "2022-01-24T00:00:00.000Z",
        "dateUpdated": "2024-08-03T17:16:04.261Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2021-3519 (GCVE-0-2021-3519)

    Vulnerability from nvd – Published: 2021-11-12 22:05 – Updated: 2024-08-03 17:01
    VLAI
    Summary
    A vulnerability was reported in some Lenovo Desktop models that could allow unauthorized access to the boot menu, when the "BIOS Password At Boot Device List" BIOS setting is Yes.
    CWE
    • CWE-287 - Improper Authentication
    Assigner
    References
    Impacted products
    Vendor Product Version
    Lenovo Desktop BIOS Affected: various
    Create a notification for this product.
    Credits
    Lenovo thanks Pawel Urbanek for reporting this issue.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T17:01:07.319Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://support.lenovo.com/us/en/product_security/LEN-67440"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "Desktop BIOS",
              "vendor": "Lenovo",
              "versions": [
                {
                  "status": "affected",
                  "version": "various"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "value": "Lenovo thanks Pawel Urbanek for reporting this issue."
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability was reported in some Lenovo Desktop models that could allow unauthorized access to the boot menu, when the \"BIOS Password At Boot Device List\" BIOS setting is Yes."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "PHYSICAL",
                "availabilityImpact": "HIGH",
                "baseScore": 6.4,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "LOW",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:L/A:H",
                "version": "3.1"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-287",
                  "description": "CWE-287 Improper Authentication",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2021-11-12T22:05:29.000Z",
            "orgId": "da227ddf-6e25-4b41-b023-0f976dcaca4b",
            "shortName": "lenovo"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://support.lenovo.com/us/en/product_security/LEN-67440"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "value": "Update system firmware to the version (or newer) indicated for your model in the Product Impact section of LEN-67440."
            }
          ],
          "source": {
            "advisory": "LEN-67440",
            "discovery": "UNKNOWN"
          },
          "x_generator": {
            "engine": "Vulnogram 0.0.9"
          },
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "psirt@lenovo.com",
              "ID": "CVE-2021-3519",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "Desktop BIOS",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "=",
                                "version_value": "various"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "Lenovo"
                  }
                ]
              }
            },
            "credit": [
              {
                "lang": "eng",
                "value": "Lenovo thanks Pawel Urbanek for reporting this issue."
              }
            ],
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "A vulnerability was reported in some Lenovo Desktop models that could allow unauthorized access to the boot menu, when the \"BIOS Password At Boot Device List\" BIOS setting is Yes."
                }
              ]
            },
            "generator": {
              "engine": "Vulnogram 0.0.9"
            },
            "impact": {
              "cvss": {
                "attackComplexity": "LOW",
                "attackVector": "PHYSICAL",
                "availabilityImpact": "HIGH",
                "baseScore": 6.4,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "LOW",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:L/A:H",
                "version": "3.1"
              }
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-287 Improper Authentication"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://support.lenovo.com/us/en/product_security/LEN-67440",
                  "refsource": "MISC",
                  "url": "https://support.lenovo.com/us/en/product_security/LEN-67440"
                }
              ]
            },
            "solution": [
              {
                "lang": "en",
                "value": "Update system firmware to the version (or newer) indicated for your model in the Product Impact section of LEN-67440."
              }
            ],
            "source": {
              "advisory": "LEN-67440",
              "discovery": "UNKNOWN"
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "da227ddf-6e25-4b41-b023-0f976dcaca4b",
        "assignerShortName": "lenovo",
        "cveId": "CVE-2021-3519",
        "datePublished": "2021-11-12T22:05:29.000Z",
        "dateReserved": "2021-04-27T00:00:00.000Z",
        "dateUpdated": "2024-08-03T17:01:07.319Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2023-45079 (GCVE-0-2023-45079)

    Vulnerability from cvelistv5 – Published: 2023-11-08 22:32 – Updated: 2024-09-04 17:43
    VLAI
    Summary
    A memory leakage vulnerability was reported in the NvmramSmm SMM driver that may allow a local attacker with elevated privileges to write to NVRAM variables.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    Assigner
    Impacted products
    Vendor Product Version
    Lenovo BIOS Affected: various
    Create a notification for this product.
    lenovo bios Affected: various
        cpe:2.3:o:lenovo:bios:-:*:*:*:*:*:*:*
    Create a notification for this product.
    Credits
    Lenovo thanks Souhardya Sardar of Cyberstanc for reporting this issue.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T20:14:19.032Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://support.lenovo.com/us/en/product_security/LEN-141775"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "affected": [
              {
                "cpes": [
                  "cpe:2.3:o:lenovo:bios:-:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "bios",
                "vendor": "lenovo",
                "versions": [
                  {
                    "status": "affected",
                    "version": "various"
                  }
                ]
              }
            ],
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2023-45079",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-09-04T17:42:45.727166Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-09-04T17:43:46.981Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "BIOS",
              "vendor": "Lenovo",
              "versions": [
                {
                  "status": "affected",
                  "version": "various"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Lenovo thanks Souhardya Sardar of Cyberstanc for reporting this issue."
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "A memory leakage vulnerability was reported in the NvmramSmm SMM driver that may allow a local attacker with elevated privileges to write to NVRAM variables. \u003cbr\u003e\u003cbr\u003e"
                }
              ],
              "value": "A memory leakage vulnerability was reported in the NvmramSmm SMM driver that may allow a local attacker with elevated privileges to write to NVRAM variables. \n\n"
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "HIGH",
                "baseScore": 6.7,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "HIGH",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-125",
                  "description": "CWE-125 Out-of-bounds Read",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2023-11-08T22:32:37.592Z",
            "orgId": "da227ddf-6e25-4b41-b023-0f976dcaca4b",
            "shortName": "lenovo"
          },
          "references": [
            {
              "url": "https://support.lenovo.com/us/en/product_security/LEN-141775"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Update system firmware to the version (or newer) indicated for your model in the advisory: \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://support.lenovo.com/us/en/product_security/LEN-141775\"\u003ehttps://support.lenovo.com/us/en/product_security/LEN-141775\u003c/a\u003e"
                }
              ],
              "value": "Update system firmware to the version (or newer) indicated for your model in the advisory:  https://support.lenovo.com/us/en/product_security/LEN-141775 "
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "da227ddf-6e25-4b41-b023-0f976dcaca4b",
        "assignerShortName": "lenovo",
        "cveId": "CVE-2023-45079",
        "datePublished": "2023-11-08T22:32:37.592Z",
        "dateReserved": "2023-10-03T17:36:49.034Z",
        "dateUpdated": "2024-09-04T17:43:46.981Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2023-45078 (GCVE-0-2023-45078)

    Vulnerability from cvelistv5 – Published: 2023-11-08 22:30 – Updated: 2024-09-04 17:50
    VLAI
    Summary
    A memory leakage vulnerability was reported in the DustFilterAlertSmm SMM driver that may allow a local attacker with elevated privileges to write to NVRAM variables.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    Assigner
    Impacted products
    Vendor Product Version
    Lenovo BIOS Affected: various
    Create a notification for this product.
    lenovo bios Affected: various
        cpe:2.3:o:lenovo:bios:-:*:*:*:*:*:*:*
    Create a notification for this product.
    Credits
    Lenovo thanks Souhardya Sardar of Cyberstanc for reporting this issue.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T20:14:18.388Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://support.lenovo.com/us/en/product_security/LEN-141775"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "affected": [
              {
                "cpes": [
                  "cpe:2.3:o:lenovo:bios:-:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "bios",
                "vendor": "lenovo",
                "versions": [
                  {
                    "status": "affected",
                    "version": "various"
                  }
                ]
              }
            ],
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2023-45078",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-09-04T17:48:51.693243Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-09-04T17:50:14.651Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "BIOS",
              "vendor": "Lenovo",
              "versions": [
                {
                  "status": "affected",
                  "version": "various"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Lenovo thanks Souhardya Sardar of Cyberstanc for reporting this issue."
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "A memory leakage vulnerability was reported in the DustFilterAlertSmm SMM driver that may allow a local attacker with elevated privileges to write to NVRAM variables. "
                }
              ],
              "value": "A memory leakage vulnerability was reported in the DustFilterAlertSmm SMM driver that may allow a local attacker with elevated privileges to write to NVRAM variables. "
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "HIGH",
                "baseScore": 6.7,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "HIGH",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-125",
                  "description": "CWE-125 Out-of-bounds Read",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2023-11-08T22:30:49.077Z",
            "orgId": "da227ddf-6e25-4b41-b023-0f976dcaca4b",
            "shortName": "lenovo"
          },
          "references": [
            {
              "url": "https://support.lenovo.com/us/en/product_security/LEN-141775"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Update system firmware to the version (or newer) indicated for your model in the advisory: \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://support.lenovo.com/us/en/product_security/LEN-141775\"\u003ehttps://support.lenovo.com/us/en/product_security/LEN-141775\u003c/a\u003e"
                }
              ],
              "value": "Update system firmware to the version (or newer) indicated for your model in the advisory:  https://support.lenovo.com/us/en/product_security/LEN-141775 "
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "da227ddf-6e25-4b41-b023-0f976dcaca4b",
        "assignerShortName": "lenovo",
        "cveId": "CVE-2023-45078",
        "datePublished": "2023-11-08T22:30:49.077Z",
        "dateReserved": "2023-10-03T17:36:49.034Z",
        "dateUpdated": "2024-09-04T17:50:14.651Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2023-45077 (GCVE-0-2023-45077)

    Vulnerability from cvelistv5 – Published: 2023-11-08 22:30 – Updated: 2024-09-04 17:54
    VLAI
    Summary
    A memory leakage vulnerability was reported in the 534D0740 DXE driver that may allow a local attacker with elevated privileges to write to NVRAM variables.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    Assigner
    Impacted products
    Vendor Product Version
    Lenovo BIOS Affected: various
    Create a notification for this product.
    lenovo bios Affected: various
        cpe:2.3:o:lenovo:bios:-:*:*:*:*:*:*:*
    Create a notification for this product.
    Credits
    Lenovo thanks Souhardya Sardar of Cyberstanc for reporting this issue.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T20:14:19.032Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://support.lenovo.com/us/en/product_security/LEN-141775"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "affected": [
              {
                "cpes": [
                  "cpe:2.3:o:lenovo:bios:-:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "bios",
                "vendor": "lenovo",
                "versions": [
                  {
                    "status": "affected",
                    "version": "various"
                  }
                ]
              }
            ],
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2023-45077",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-09-04T17:52:03.826324Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-09-04T17:54:09.101Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "BIOS",
              "vendor": "Lenovo",
              "versions": [
                {
                  "status": "affected",
                  "version": "various"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Lenovo thanks Souhardya Sardar of Cyberstanc for reporting this issue."
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "A memory leakage vulnerability was reported in the 534D0740 DXE driver that may allow a local attacker with elevated privileges to write to NVRAM variables. "
                }
              ],
              "value": "A memory leakage vulnerability was reported in the 534D0740 DXE driver that may allow a local attacker with elevated privileges to write to NVRAM variables. "
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "HIGH",
                "baseScore": 6.7,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "HIGH",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-125",
                  "description": "CWE-125 Out-of-bounds Read",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2023-11-08T22:38:59.712Z",
            "orgId": "da227ddf-6e25-4b41-b023-0f976dcaca4b",
            "shortName": "lenovo"
          },
          "references": [
            {
              "url": "https://support.lenovo.com/us/en/product_security/LEN-141775"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Update system firmware to the version (or newer) indicated for your model in the advisory: \u003ca href=\"https://support.lenovo.com/us/en/product_security/LEN-141775\"\u003ehttps://support.lenovo.com/us/en/product_security/LEN-141775\u003c/a\u003e"
                }
              ],
              "value": "Update system firmware to the version (or newer) indicated for your model in the advisory:  https://support.lenovo.com/us/en/product_security/LEN-141775 "
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "da227ddf-6e25-4b41-b023-0f976dcaca4b",
        "assignerShortName": "lenovo",
        "cveId": "CVE-2023-45077",
        "datePublished": "2023-11-08T22:30:05.886Z",
        "dateReserved": "2023-10-03T17:36:49.034Z",
        "dateUpdated": "2024-09-04T17:54:09.101Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2023-45076 (GCVE-0-2023-45076)

    Vulnerability from cvelistv5 – Published: 2023-11-08 22:28 – Updated: 2024-09-04 17:56
    VLAI
    Summary
    A memory leakage vulnerability was reported in the 534D0140 DXE driver that may allow a local attacker with elevated privileges to write to NVRAM variables.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    Assigner
    Impacted products
    Vendor Product Version
    Lenovo BIOS Affected: various
    Create a notification for this product.
    lenovo bios Affected: various
        cpe:2.3:o:lenovo:bios:-:*:*:*:*:*:*:*
    Create a notification for this product.
    Credits
    Lenovo thanks Souhardya Sardar of Cyberstanc for reporting this issue.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T20:14:19.503Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://support.lenovo.com/us/en/product_security/LEN-141775"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "affected": [
              {
                "cpes": [
                  "cpe:2.3:o:lenovo:bios:-:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "bios",
                "vendor": "lenovo",
                "versions": [
                  {
                    "status": "affected",
                    "version": "various"
                  }
                ]
              }
            ],
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2023-45076",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-09-04T17:55:45.684582Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-09-04T17:56:30.453Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "BIOS",
              "vendor": "Lenovo",
              "versions": [
                {
                  "status": "affected",
                  "version": "various"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Lenovo thanks Souhardya Sardar of Cyberstanc for reporting this issue."
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "A memory leakage vulnerability was reported in the 534D0140 DXE driver that may allow a local attacker with elevated privileges to write to NVRAM variables.\u003cbr\u003e"
                }
              ],
              "value": "A memory leakage vulnerability was reported in the 534D0140 DXE driver that may allow a local attacker with elevated privileges to write to NVRAM variables.\n"
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "HIGH",
                "baseScore": 6.7,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "HIGH",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-125",
                  "description": "CWE-125 Out-of-bounds Read",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2023-11-08T22:28:20.459Z",
            "orgId": "da227ddf-6e25-4b41-b023-0f976dcaca4b",
            "shortName": "lenovo"
          },
          "references": [
            {
              "url": "https://support.lenovo.com/us/en/product_security/LEN-141775"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Update system firmware to the version (or newer) indicated for your model in the advisory: \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://support.lenovo.com/us/en/product_security/LEN-141775\"\u003ehttps://support.lenovo.com/us/en/product_security/LEN-141775\u003c/a\u003e"
                }
              ],
              "value": "Update system firmware to the version (or newer) indicated for your model in the advisory:  https://support.lenovo.com/us/en/product_security/LEN-141775 "
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "da227ddf-6e25-4b41-b023-0f976dcaca4b",
        "assignerShortName": "lenovo",
        "cveId": "CVE-2023-45076",
        "datePublished": "2023-11-08T22:28:20.459Z",
        "dateReserved": "2023-10-03T17:36:49.034Z",
        "dateUpdated": "2024-09-04T17:56:30.453Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2023-45075 (GCVE-0-2023-45075)

    Vulnerability from cvelistv5 – Published: 2023-11-08 22:27 – Updated: 2024-09-04 17:58
    VLAI
    Summary
    A memory leakage vulnerability was reported in the SWSMI_Shadow DXE driver that may allow a local attacker with elevated privileges to write to NVRAM variables.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    Assigner
    Impacted products
    Vendor Product Version
    Lenovo BIOS Affected: various
    Create a notification for this product.
    lenovo bios Affected: various
        cpe:2.3:o:lenovo:bios:-:*:*:*:*:*:*:*
    Create a notification for this product.
    Credits
    Lenovo thanks Souhardya Sardar of Cyberstanc for reporting this issue.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T20:14:19.819Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://support.lenovo.com/us/en/product_security/LEN-141775"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "affected": [
              {
                "cpes": [
                  "cpe:2.3:o:lenovo:bios:-:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "bios",
                "vendor": "lenovo",
                "versions": [
                  {
                    "status": "affected",
                    "version": "various"
                  }
                ]
              }
            ],
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2023-45075",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-09-04T17:57:18.522310Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-09-04T17:58:47.396Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "BIOS",
              "vendor": "Lenovo",
              "versions": [
                {
                  "status": "affected",
                  "version": "various"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Lenovo thanks Souhardya Sardar of Cyberstanc for reporting this issue."
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "A memory leakage vulnerability was reported in the SWSMI_Shadow DXE driver that may allow a local attacker with elevated privileges to write to NVRAM variables."
                }
              ],
              "value": "A memory leakage vulnerability was reported in the SWSMI_Shadow DXE driver that may allow a local attacker with elevated privileges to write to NVRAM variables."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "HIGH",
                "baseScore": 6.7,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "HIGH",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-125",
                  "description": "CWE-125 Out-of-bounds Read",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2023-11-08T22:27:32.659Z",
            "orgId": "da227ddf-6e25-4b41-b023-0f976dcaca4b",
            "shortName": "lenovo"
          },
          "references": [
            {
              "url": "https://support.lenovo.com/us/en/product_security/LEN-141775"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Update system firmware to the version (or newer) indicated for your model in the advisory: \u003ca href=\"https://support.lenovo.com/us/en/product_security/LEN-141775\"\u003ehttps://support.lenovo.com/us/en/product_security/LEN-141775\u003c/a\u003e"
                }
              ],
              "value": "Update system firmware to the version (or newer) indicated for your model in the advisory:  https://support.lenovo.com/us/en/product_security/LEN-141775 "
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "da227ddf-6e25-4b41-b023-0f976dcaca4b",
        "assignerShortName": "lenovo",
        "cveId": "CVE-2023-45075",
        "datePublished": "2023-11-08T22:27:32.659Z",
        "dateReserved": "2023-10-03T17:36:49.034Z",
        "dateUpdated": "2024-09-04T17:58:47.396Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2022-40136 (GCVE-0-2022-40136)

    Vulnerability from cvelistv5 – Published: 2023-01-30 21:20 – Updated: 2025-03-27 15:25
    VLAI
    Summary
    An information leak vulnerability in SMI Handler used to configure platform settings over WMI in some Lenovo models may allow an attacker with local access and elevated privileges to read SMM memory.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    Assigner
    Impacted products
    Vendor Product Version
    Lenovo BIOS Affected: various
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T12:14:39.820Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://support.lenovo.com/us/en/product_security/LEN-94953"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2022-40136",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-03-27T15:24:54.142774Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-03-27T15:25:10.981Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "BIOS",
              "vendor": "Lenovo",
              "versions": [
                {
                  "status": "affected",
                  "version": "various"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "An information leak vulnerability in SMI Handler used to configure platform settings over WMI in some Lenovo models may allow an attacker with local access and elevated privileges to read SMM memory."
                }
              ],
              "value": "An information leak vulnerability in SMI Handler used to configure platform settings over WMI in some Lenovo models may allow an attacker with local access and elevated privileges to read SMM memory."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "NONE",
                "baseScore": 4.4,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "NONE",
                "privilegesRequired": "HIGH",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:N/A:N",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-125",
                  "description": "CWE-125 Out-of-bounds Read",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2023-01-30T21:20:45.280Z",
            "orgId": "da227ddf-6e25-4b41-b023-0f976dcaca4b",
            "shortName": "lenovo"
          },
          "references": [
            {
              "url": "https://support.lenovo.com/us/en/product_security/LEN-94953"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Update system firmware to the version (or newer) indicated for your model in the Product Impact section of LEN-94953."
                }
              ],
              "value": "Update system firmware to the version (or newer) indicated for your model in the Product Impact section of LEN-94953."
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "da227ddf-6e25-4b41-b023-0f976dcaca4b",
        "assignerShortName": "lenovo",
        "cveId": "CVE-2022-40136",
        "datePublished": "2023-01-30T21:20:45.280Z",
        "dateReserved": "2022-09-06T15:43:50.236Z",
        "dateUpdated": "2025-03-27T15:25:10.981Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2022-40135 (GCVE-0-2022-40135)

    Vulnerability from cvelistv5 – Published: 2023-01-30 21:20 – Updated: 2025-03-27 15:26
    VLAI
    Summary
    An information leak vulnerability in the Smart USB Protection SMI Handler in some Lenovo models may allow an attacker with local access and elevated privileges to read SMM memory.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    Assigner
    Impacted products
    Vendor Product Version
    Lenovo BIOS Affected: various
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T12:14:39.736Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://support.lenovo.com/us/en/product_security/LEN-94953"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2022-40135",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-03-27T15:25:43.013586Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-03-27T15:26:04.196Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "BIOS",
              "vendor": "Lenovo",
              "versions": [
                {
                  "status": "affected",
                  "version": "various"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "An information leak vulnerability in the Smart USB Protection SMI Handler in some Lenovo models may allow an attacker with local access and elevated privileges to read SMM memory."
                }
              ],
              "value": "An information leak vulnerability in the Smart USB Protection SMI Handler in some Lenovo models may allow an attacker with local access and elevated privileges to read SMM memory."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "NONE",
                "baseScore": 4.4,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "NONE",
                "privilegesRequired": "HIGH",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:N/A:N",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-125",
                  "description": "CWE-125 Out-of-bounds Read",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2023-01-30T21:20:33.347Z",
            "orgId": "da227ddf-6e25-4b41-b023-0f976dcaca4b",
            "shortName": "lenovo"
          },
          "references": [
            {
              "url": "https://support.lenovo.com/us/en/product_security/LEN-94953"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Update system firmware to the version (or newer) indicated for your model in the Product Impact section of LEN-94953."
                }
              ],
              "value": "Update system firmware to the version (or newer) indicated for your model in the Product Impact section of LEN-94953."
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "da227ddf-6e25-4b41-b023-0f976dcaca4b",
        "assignerShortName": "lenovo",
        "cveId": "CVE-2022-40135",
        "datePublished": "2023-01-30T21:20:33.347Z",
        "dateReserved": "2022-09-06T15:43:50.236Z",
        "dateUpdated": "2025-03-27T15:26:04.196Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2022-40134 (GCVE-0-2022-40134)

    Vulnerability from cvelistv5 – Published: 2023-01-30 21:20 – Updated: 2025-03-27 15:26
    VLAI
    Summary
    An information leak vulnerability in the SMI Set BIOS Password SMI Handler in some Lenovo models may allow an attacker with local access and elevated privileges to read SMM memory.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    Assigner
    Impacted products
    Vendor Product Version
    Lenovo BIOS Affected: various
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T12:14:39.959Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://support.lenovo.com/us/en/product_security/LEN-94953"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2022-40134",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-03-27T15:26:39.063546Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-03-27T15:26:52.831Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "BIOS",
              "vendor": "Lenovo",
              "versions": [
                {
                  "status": "affected",
                  "version": "various"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "An information leak vulnerability in the SMI Set BIOS Password SMI Handler in some Lenovo models may allow an attacker with local access and elevated privileges to read SMM memory."
                }
              ],
              "value": "An information leak vulnerability in the SMI Set BIOS Password SMI Handler in some Lenovo models may allow an attacker with local access and elevated privileges to read SMM memory."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "NONE",
                "baseScore": 4.4,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "NONE",
                "privilegesRequired": "HIGH",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:N/A:N",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-125",
                  "description": "CWE-125 Out-of-bounds Read",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2023-01-30T21:20:25.236Z",
            "orgId": "da227ddf-6e25-4b41-b023-0f976dcaca4b",
            "shortName": "lenovo"
          },
          "references": [
            {
              "url": "https://support.lenovo.com/us/en/product_security/LEN-94953"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Update system firmware to the version (or newer) indicated for your model in the Product Impact section of LEN-94953."
                }
              ],
              "value": "Update system firmware to the version (or newer) indicated for your model in the Product Impact section of LEN-94953."
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "da227ddf-6e25-4b41-b023-0f976dcaca4b",
        "assignerShortName": "lenovo",
        "cveId": "CVE-2022-40134",
        "datePublished": "2023-01-30T21:20:25.236Z",
        "dateReserved": "2022-09-06T15:43:50.235Z",
        "dateUpdated": "2025-03-27T15:26:52.831Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2021-4211 (GCVE-0-2021-4211)

    Vulnerability from cvelistv5 – Published: 2022-04-22 20:30 – Updated: 2024-08-03 17:16
    VLAI
    Summary
    A potential vulnerability in the SMI callback function used in the SMBIOS event log driver in some Lenovo Desktop, ThinkStation, and ThinkEdge models may allow an attacker with local access and elevated privileges to execute arbitrary code.
    CWE
    • CWE-20 - Improper Input Validation
    Assigner
    References
    Impacted products
    Vendor Product Version
    Lenovo BIOS Affected: various
    Create a notification for this product.
    Credits
    Lenovo thanks Jiawei Yin(@yngweijw) and Menghao Li of IIE varas
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T17:16:04.358Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://support.lenovo.com/us/en/product_security/LEN-77639"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "BIOS",
              "vendor": "Lenovo",
              "versions": [
                {
                  "status": "affected",
                  "version": "various"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "value": "Lenovo thanks Jiawei Yin(@yngweijw) and Menghao Li of IIE varas"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A potential vulnerability in the SMI callback function used in the SMBIOS event log driver in some Lenovo Desktop, ThinkStation, and ThinkEdge models may allow an attacker with local access and elevated privileges to execute arbitrary code."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "HIGH",
                "baseScore": 6.7,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "HIGH",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-20",
                  "description": "CWE-20 Improper Input Validation",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2022-04-22T20:30:43.000Z",
            "orgId": "da227ddf-6e25-4b41-b023-0f976dcaca4b",
            "shortName": "lenovo"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://support.lenovo.com/us/en/product_security/LEN-77639"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "value": "Update system firmware to the version (or newer) indicated for your model in the Product Impact section in LEN-77639."
            }
          ],
          "source": {
            "advisory": "LEN-77639",
            "discovery": "UNKNOWN"
          },
          "x_generator": {
            "engine": "Vulnogram 0.0.9"
          },
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "psirt@lenovo.com",
              "ID": "CVE-2021-4211",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "BIOS",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "=",
                                "version_value": "various"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "Lenovo"
                  }
                ]
              }
            },
            "credit": [
              {
                "lang": "eng",
                "value": "Lenovo thanks Jiawei Yin(@yngweijw) and Menghao Li of IIE varas"
              }
            ],
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "A potential vulnerability in the SMI callback function used in the SMBIOS event log driver in some Lenovo Desktop, ThinkStation, and ThinkEdge models may allow an attacker with local access and elevated privileges to execute arbitrary code."
                }
              ]
            },
            "generator": {
              "engine": "Vulnogram 0.0.9"
            },
            "impact": {
              "cvss": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "HIGH",
                "baseScore": 6.7,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "HIGH",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              }
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-20 Improper Input Validation"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://support.lenovo.com/us/en/product_security/LEN-77639",
                  "refsource": "MISC",
                  "url": "https://support.lenovo.com/us/en/product_security/LEN-77639"
                }
              ]
            },
            "solution": [
              {
                "lang": "en",
                "value": "Update system firmware to the version (or newer) indicated for your model in the Product Impact section in LEN-77639."
              }
            ],
            "source": {
              "advisory": "LEN-77639",
              "discovery": "UNKNOWN"
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "da227ddf-6e25-4b41-b023-0f976dcaca4b",
        "assignerShortName": "lenovo",
        "cveId": "CVE-2021-4211",
        "datePublished": "2022-04-22T20:30:43.000Z",
        "dateReserved": "2022-01-24T00:00:00.000Z",
        "dateUpdated": "2024-08-03T17:16:04.358Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2021-4210 (GCVE-0-2021-4210)

    Vulnerability from cvelistv5 – Published: 2022-04-22 20:30 – Updated: 2024-08-03 17:16
    VLAI
    Summary
    A potential vulnerability in the SMI callback function used in the NVME driver in some Lenovo Desktop, ThinkStation, and ThinkEdge models may allow an attacker with local access and elevated privileges to execute arbitrary code.
    CWE
    • CWE-20 - Improper Input Validation
    Assigner
    References
    Impacted products
    Vendor Product Version
    Lenovo BIOS Affected: various
    Create a notification for this product.
    Credits
    Lenovo thanks Jiawei Yin(@yngweijw) and Menghao Li of IIE varas
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T17:16:04.261Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://support.lenovo.com/us/en/product_security/LEN-77639"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "BIOS",
              "vendor": "Lenovo",
              "versions": [
                {
                  "status": "affected",
                  "version": "various"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "value": "Lenovo thanks Jiawei Yin(@yngweijw) and Menghao Li of IIE varas"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A potential vulnerability in the SMI callback function used in the NVME driver in some Lenovo Desktop, ThinkStation, and ThinkEdge models may allow an attacker with local access and elevated privileges to execute arbitrary code."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "HIGH",
                "baseScore": 6.7,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "HIGH",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-20",
                  "description": "CWE-20 Improper Input Validation",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2022-04-22T20:30:41.000Z",
            "orgId": "da227ddf-6e25-4b41-b023-0f976dcaca4b",
            "shortName": "lenovo"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://support.lenovo.com/us/en/product_security/LEN-77639"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "value": "Update system firmware to the version (or newer) indicated for your model in the Product Impact section in LEN-77639."
            }
          ],
          "source": {
            "advisory": "LEN-77639",
            "discovery": "UNKNOWN"
          },
          "x_generator": {
            "engine": "Vulnogram 0.0.9"
          },
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "psirt@lenovo.com",
              "ID": "CVE-2021-4210",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "BIOS",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "=",
                                "version_value": "various"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "Lenovo"
                  }
                ]
              }
            },
            "credit": [
              {
                "lang": "eng",
                "value": "Lenovo thanks Jiawei Yin(@yngweijw) and Menghao Li of IIE varas"
              }
            ],
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "A potential vulnerability in the SMI callback function used in the NVME driver in some Lenovo Desktop, ThinkStation, and ThinkEdge models may allow an attacker with local access and elevated privileges to execute arbitrary code."
                }
              ]
            },
            "generator": {
              "engine": "Vulnogram 0.0.9"
            },
            "impact": {
              "cvss": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "HIGH",
                "baseScore": 6.7,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "HIGH",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              }
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-20 Improper Input Validation"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://support.lenovo.com/us/en/product_security/LEN-77639",
                  "refsource": "MISC",
                  "url": "https://support.lenovo.com/us/en/product_security/LEN-77639"
                }
              ]
            },
            "solution": [
              {
                "lang": "en",
                "value": "Update system firmware to the version (or newer) indicated for your model in the Product Impact section in LEN-77639."
              }
            ],
            "source": {
              "advisory": "LEN-77639",
              "discovery": "UNKNOWN"
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "da227ddf-6e25-4b41-b023-0f976dcaca4b",
        "assignerShortName": "lenovo",
        "cveId": "CVE-2021-4210",
        "datePublished": "2022-04-22T20:30:41.000Z",
        "dateReserved": "2022-01-24T00:00:00.000Z",
        "dateUpdated": "2024-08-03T17:16:04.261Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2021-3519 (GCVE-0-2021-3519)

    Vulnerability from cvelistv5 – Published: 2021-11-12 22:05 – Updated: 2024-08-03 17:01
    VLAI
    Summary
    A vulnerability was reported in some Lenovo Desktop models that could allow unauthorized access to the boot menu, when the "BIOS Password At Boot Device List" BIOS setting is Yes.
    CWE
    • CWE-287 - Improper Authentication
    Assigner
    References
    Impacted products
    Vendor Product Version
    Lenovo Desktop BIOS Affected: various
    Create a notification for this product.
    Credits
    Lenovo thanks Pawel Urbanek for reporting this issue.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T17:01:07.319Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://support.lenovo.com/us/en/product_security/LEN-67440"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "Desktop BIOS",
              "vendor": "Lenovo",
              "versions": [
                {
                  "status": "affected",
                  "version": "various"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "value": "Lenovo thanks Pawel Urbanek for reporting this issue."
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability was reported in some Lenovo Desktop models that could allow unauthorized access to the boot menu, when the \"BIOS Password At Boot Device List\" BIOS setting is Yes."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "PHYSICAL",
                "availabilityImpact": "HIGH",
                "baseScore": 6.4,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "LOW",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:L/A:H",
                "version": "3.1"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-287",
                  "description": "CWE-287 Improper Authentication",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2021-11-12T22:05:29.000Z",
            "orgId": "da227ddf-6e25-4b41-b023-0f976dcaca4b",
            "shortName": "lenovo"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://support.lenovo.com/us/en/product_security/LEN-67440"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "value": "Update system firmware to the version (or newer) indicated for your model in the Product Impact section of LEN-67440."
            }
          ],
          "source": {
            "advisory": "LEN-67440",
            "discovery": "UNKNOWN"
          },
          "x_generator": {
            "engine": "Vulnogram 0.0.9"
          },
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "psirt@lenovo.com",
              "ID": "CVE-2021-3519",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "Desktop BIOS",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "=",
                                "version_value": "various"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "Lenovo"
                  }
                ]
              }
            },
            "credit": [
              {
                "lang": "eng",
                "value": "Lenovo thanks Pawel Urbanek for reporting this issue."
              }
            ],
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "A vulnerability was reported in some Lenovo Desktop models that could allow unauthorized access to the boot menu, when the \"BIOS Password At Boot Device List\" BIOS setting is Yes."
                }
              ]
            },
            "generator": {
              "engine": "Vulnogram 0.0.9"
            },
            "impact": {
              "cvss": {
                "attackComplexity": "LOW",
                "attackVector": "PHYSICAL",
                "availabilityImpact": "HIGH",
                "baseScore": 6.4,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "LOW",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:L/A:H",
                "version": "3.1"
              }
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-287 Improper Authentication"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://support.lenovo.com/us/en/product_security/LEN-67440",
                  "refsource": "MISC",
                  "url": "https://support.lenovo.com/us/en/product_security/LEN-67440"
                }
              ]
            },
            "solution": [
              {
                "lang": "en",
                "value": "Update system firmware to the version (or newer) indicated for your model in the Product Impact section of LEN-67440."
              }
            ],
            "source": {
              "advisory": "LEN-67440",
              "discovery": "UNKNOWN"
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "da227ddf-6e25-4b41-b023-0f976dcaca4b",
        "assignerShortName": "lenovo",
        "cveId": "CVE-2021-3519",
        "datePublished": "2021-11-12T22:05:29.000Z",
        "dateReserved": "2021-04-27T00:00:00.000Z",
        "dateUpdated": "2024-08-03T17:01:07.319Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }