    FKIE_CVE-2013-2782

    Vulnerability from fkie_nvd - Published: 2013-08-28 13:09 - Updated: 2026-06-16 23:53
    Severity
    Summary
    Schneider Electric Trio J-Series License Free Ethernet Radio with firmware 3.6.0 through 3.6.3 uses the same AES encryption key across different customers' installations, which makes it easier for remote attackers to defeat cryptographic protection mechanisms by leveraging knowledge of this key from another installation.

    {
      "affected": [
        {
          "affectedData": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "source": "ics-cert@hq.dhs.gov"
        }
      ],
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:schneider-electric:tburjr900:00002dh0:*:*:*:*:*:*:*",
                  "matchCriteriaId": "3689A9D3-40FB-4135-A9D3-DFC7AFE7B10B",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:h:schneider-electric:tburjr900:00002eh0:*:*:*:*:*:*:*",
                  "matchCriteriaId": "A92E024D-02C0-4B76-8352-ED5357DE34CA",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:h:schneider-electric:tburjr900:01002dh0:*:*:*:*:*:*:*",
                  "matchCriteriaId": "816CA3DE-9453-4D60-886B-2BFED178B81B",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:h:schneider-electric:tburjr900:01002eh0:*:*:*:*:*:*:*",
                  "matchCriteriaId": "9BF82506-8036-4928-9C88-F1DB3B7CCD74",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:h:schneider-electric:tburjr900:05002dh0:*:*:*:*:*:*:*",
                  "matchCriteriaId": "61D7AD31-432E-48AE-A0FB-C6868164A461",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:h:schneider-electric:tburjr900:05002eh0:*:*:*:*:*:*:*",
                  "matchCriteriaId": "07890C35-BB97-416E-A451-9AE2B35FA83A",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:h:schneider-electric:tburjr900:06002dh0:*:*:*:*:*:*:*",
                  "matchCriteriaId": "5DB839C6-C3D3-4C61-BC6B-F550AF152965",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:h:schneider-electric:tburjr900:06002eh0:*:*:*:*:*:*:*",
                  "matchCriteriaId": "580C28C8-0136-4F1F-8768-DF4C2F2A0500",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:schneider-electric:tburjr900_firmware:3.6.0:*:*:*:*:*:*:*",
                  "matchCriteriaId": "29917F5D-651B-40C5-B5F7-0170B90389FA",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:schneider-electric:tburjr900_firmware:3.6.1:*:*:*:*:*:*:*",
                  "matchCriteriaId": "483A3AE5-8421-47CB-8CB8-689D594EDE11",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:schneider-electric:tburjr900_firmware:3.6.2:*:*:*:*:*:*:*",
                  "matchCriteriaId": "4B1C8EB0-8562-44B0-9BAE-891089695AE8",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:schneider-electric:tburjr900_firmware:3.6.3:*:*:*:*:*:*:*",
                  "matchCriteriaId": "73E32FDE-9828-4E29-B0C0-BB1899A3296A",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        }
      ],
      "cveTags": [],
      "descriptions": [
        {
          "lang": "en",
          "value": "Schneider Electric Trio J-Series License Free Ethernet Radio with firmware 3.6.0 through 3.6.3 uses the same AES encryption key across different customers\u0027 installations, which makes it easier for remote attackers to defeat cryptographic protection mechanisms by leveraging knowledge of this key from another installation."
        },
        {
          "lang": "es",
          "value": "Schneider Electric Trio J-Series License Free Ethernet Radio con firmware v3.6.0 hasta v3.6.3 utiliza la misma clave de cifrado AES en las distintas instalaciones de los clientes, lo que hace que sea m\u00e1s f\u00e1cil para los atacantes remotos saltarse los mecanismos de protecci\u00f3n de cifrado, mediante el aprovechamiento de los conocimientos de esta clave a partir de otra instalaci\u00f3n."
        }
      ],
      "id": "CVE-2013-2782",
      "lastModified": "2026-06-16T23:53:57.617",
      "metrics": {
        "cvssMetricV2": [
          {
            "acInsufInfo": false,
            "baseSeverity": "HIGH",
            "cvssData": {
              "accessComplexity": "MEDIUM",
              "accessVector": "NETWORK",
              "authentication": "NONE",
              "availabilityImpact": "COMPLETE",
              "baseScore": 9.3,
              "confidentialityImpact": "COMPLETE",
              "integrityImpact": "COMPLETE",
              "vectorString": "AV:N/AC:M/Au:N/C:C/I:C/A:C",
              "version": "2.0"
            },
            "exploitabilityScore": 8.6,
            "impactScore": 10.0,
            "obtainAllPrivilege": false,
            "obtainOtherPrivilege": false,
            "obtainUserPrivilege": false,
            "source": "nvd@nist.gov",
            "type": "Primary",
            "userInteractionRequired": false
          }
        ]
      },
      "published": "2013-08-28T13:09:15.230",
      "references": [
        {
          "source": "ics-cert@hq.dhs.gov",
          "tags": [
            "US Government Resource"
          ],
          "url": "http://ics-cert.us-cert.gov/advisories/ICSA-13-234-01"
        },
        {
          "source": "ics-cert@hq.dhs.gov",
          "tags": [
            "Vendor Advisory"
          ],
          "url": "http://www.schneider-electric.com/download/ww/en/file/141141292-SEVD-2013-143-01.pdf"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "US Government Resource"
          ],
          "url": "http://ics-cert.us-cert.gov/advisories/ICSA-13-234-01"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Vendor Advisory"
          ],
          "url": "http://www.schneider-electric.com/download/ww/en/file/141141292-SEVD-2013-143-01.pdf"
        }
      ],
      "sourceIdentifier": "ics-cert@hq.dhs.gov",
      "vulnStatus": "Modified",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-310"
            }
          ],
          "source": "nvd@nist.gov",
          "type": "Primary"
        }
      ]
    }

    CVE-2013-2782 (GCVE-0-2013-2782)

    Vulnerability from nvd – Published: 2013-08-28 01:00 – Updated: 2024-09-16 16:22
    VLAI
    Summary
    Schneider Electric Trio J-Series License Free Ethernet Radio with firmware 3.6.0 through 3.6.3 uses the same AES encryption key across different customers' installations, which makes it easier for remote attackers to defeat cryptographic protection mechanisms by leveraging knowledge of this key from another installation.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Assigner
    icscert CNA under the icscert root
    CNA scorecard B 75/100 over 344 records in the last 180 days details
    References
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-06T15:44:33.682Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "http://ics-cert.us-cert.gov/advisories/ICSA-13-234-01"
              },
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "http://www.schneider-electric.com/download/ww/en/file/141141292-SEVD-2013-143-01.pdf"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Schneider Electric Trio J-Series License Free Ethernet Radio with firmware 3.6.0 through 3.6.3 uses the same AES encryption key across different customers\u0027 installations, which makes it easier for remote attackers to defeat cryptographic protection mechanisms by leveraging knowledge of this key from another installation."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2013-08-28T01:00:00.000Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "http://ics-cert.us-cert.gov/advisories/ICSA-13-234-01"
            },
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "http://www.schneider-electric.com/download/ww/en/file/141141292-SEVD-2013-143-01.pdf"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "ics-cert@hq.dhs.gov",
              "ID": "CVE-2013-2782",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Schneider Electric Trio J-Series License Free Ethernet Radio with firmware 3.6.0 through 3.6.3 uses the same AES encryption key across different customers\u0027 installations, which makes it easier for remote attackers to defeat cryptographic protection mechanisms by leveraging knowledge of this key from another installation."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "http://ics-cert.us-cert.gov/advisories/ICSA-13-234-01",
                  "refsource": "MISC",
                  "url": "http://ics-cert.us-cert.gov/advisories/ICSA-13-234-01"
                },
                {
                  "name": "http://www.schneider-electric.com/download/ww/en/file/141141292-SEVD-2013-143-01.pdf",
                  "refsource": "CONFIRM",
                  "url": "http://www.schneider-electric.com/download/ww/en/file/141141292-SEVD-2013-143-01.pdf"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2013-2782",
        "datePublished": "2013-08-28T01:00:00.000Z",
        "dateReserved": "2013-04-11T00:00:00.000Z",
        "dateUpdated": "2024-09-16T16:22:35.646Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2013-2782 (GCVE-0-2013-2782)

    Vulnerability from cvelistv5 – Published: 2013-08-28 01:00 – Updated: 2024-09-16 16:22
    VLAI
    Summary
    Schneider Electric Trio J-Series License Free Ethernet Radio with firmware 3.6.0 through 3.6.3 uses the same AES encryption key across different customers' installations, which makes it easier for remote attackers to defeat cryptographic protection mechanisms by leveraging knowledge of this key from another installation.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Assigner
    icscert CNA under the icscert root
    CNA scorecard B 75/100 over 344 records in the last 180 days details
    References
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-06T15:44:33.682Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "http://ics-cert.us-cert.gov/advisories/ICSA-13-234-01"
              },
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "http://www.schneider-electric.com/download/ww/en/file/141141292-SEVD-2013-143-01.pdf"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Schneider Electric Trio J-Series License Free Ethernet Radio with firmware 3.6.0 through 3.6.3 uses the same AES encryption key across different customers\u0027 installations, which makes it easier for remote attackers to defeat cryptographic protection mechanisms by leveraging knowledge of this key from another installation."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2013-08-28T01:00:00.000Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "http://ics-cert.us-cert.gov/advisories/ICSA-13-234-01"
            },
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "http://www.schneider-electric.com/download/ww/en/file/141141292-SEVD-2013-143-01.pdf"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "ics-cert@hq.dhs.gov",
              "ID": "CVE-2013-2782",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Schneider Electric Trio J-Series License Free Ethernet Radio with firmware 3.6.0 through 3.6.3 uses the same AES encryption key across different customers\u0027 installations, which makes it easier for remote attackers to defeat cryptographic protection mechanisms by leveraging knowledge of this key from another installation."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "http://ics-cert.us-cert.gov/advisories/ICSA-13-234-01",
                  "refsource": "MISC",
                  "url": "http://ics-cert.us-cert.gov/advisories/ICSA-13-234-01"
                },
                {
                  "name": "http://www.schneider-electric.com/download/ww/en/file/141141292-SEVD-2013-143-01.pdf",
                  "refsource": "CONFIRM",
                  "url": "http://www.schneider-electric.com/download/ww/en/file/141141292-SEVD-2013-143-01.pdf"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2013-2782",
        "datePublished": "2013-08-28T01:00:00.000Z",
        "dateReserved": "2013-04-11T00:00:00.000Z",
        "dateUpdated": "2024-09-16T16:22:35.646Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }