Search

Find a vulnerability

Search criteria

    9 vulnerabilities found for syngo_fastview by siemens-healthineers

    FKIE_CVE-2021-45465

    Vulnerability from fkie_nvd - Published: 2024-01-04 12:15 - Updated: 2026-06-17 04:13
    Summary
    A vulnerability has been identified in syngo fastView (All versions). The affected application lacks proper validation of user-supplied data when parsing BMP files. This could result in a write-what-where condition and an attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-15696)
    Impacted products
    Vendor Product Version
    siemens-healthineers syngo_fastview *

    {
      "affected": [
        {
          "affectedData": [
            {
              "defaultStatus": "unknown",
              "product": "syngo fastView",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions"
                }
              ]
            }
          ],
          "source": "productcert@siemens.com"
        }
      ],
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:siemens-healthineers:syngo_fastview:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "B7D9A743-3BE4-4523-B34F-0C8461D3C63A",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        }
      ],
      "cveTags": [],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in syngo fastView (All versions). The affected application lacks proper validation of user-supplied data when parsing BMP files. This could result in a write-what-where condition and an attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-15696)"
        },
        {
          "lang": "es",
          "value": "Se ha identificado una vulnerabilidad en syngo fastView (todas las versiones). La aplicaci\u00f3n afectada carece de una validaci\u00f3n adecuada de los datos proporcionados por el usuario al analizar archivos BMP. Esto podr\u00eda dar lugar a una condici\u00f3n de write-what-where y un atacante podr\u00eda aprovechar esta vulnerabilidad para ejecutar c\u00f3digo en el contexto del proceso actual. (ZDI-CAN-15696)"
        }
      ],
      "id": "CVE-2021-45465",
      "lastModified": "2026-06-17T04:13:25.183",
      "metrics": {
        "cvssMetricV31": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "LOCAL",
              "availabilityImpact": "HIGH",
              "baseScore": 7.8,
              "baseSeverity": "HIGH",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "REQUIRED",
              "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
              "version": "3.1"
            },
            "exploitabilityScore": 1.8,
            "impactScore": 5.9,
            "source": "productcert@siemens.com",
            "type": "Secondary"
          },
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "LOCAL",
              "availabilityImpact": "HIGH",
              "baseScore": 7.8,
              "baseSeverity": "HIGH",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "REQUIRED",
              "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
              "version": "3.1"
            },
            "exploitabilityScore": 1.8,
            "impactScore": 5.9,
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ],
        "ssvcV203": [
          {
            "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
            "ssvcData": {
              "id": "CVE-2021-45465",
              "options": [
                {
                  "exploitation": "none"
                },
                {
                  "automatable": "no"
                },
                {
                  "technicalImpact": "total"
                }
              ],
              "role": "CISA Coordinator",
              "timestamp": "2025-05-08T15:48:11.356596Z",
              "version": "2.0.3"
            }
          }
        ]
      },
      "published": "2024-01-04T12:15:23.470",
      "references": [
        {
          "source": "productcert@siemens.com",
          "tags": [
            "Vendor Advisory"
          ],
          "url": "https://www.siemens-healthineers.com/en-us/support-documentation/cybersecurity/shsa-688797"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Vendor Advisory"
          ],
          "url": "https://www.siemens-healthineers.com/en-us/support-documentation/cybersecurity/shsa-688797"
        }
      ],
      "sourceIdentifier": "productcert@siemens.com",
      "vulnStatus": "Modified",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-123"
            }
          ],
          "source": "productcert@siemens.com",
          "type": "Secondary"
        }
      ]
    }

    FKIE_CVE-2021-42028

    Vulnerability from fkie_nvd - Published: 2024-01-04 12:15 - Updated: 2026-06-17 04:09
    Summary
    A vulnerability has been identified in syngo fastView (All versions). The affected application lacks proper validation of user-supplied data when parsing BMP files. This could result in an out-of-bounds write past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-14860)
    Impacted products
    Vendor Product Version
    siemens-healthineers syngo_fastview *

    {
      "affected": [
        {
          "affectedData": [
            {
              "defaultStatus": "unknown",
              "product": "syngo fastView",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions"
                }
              ]
            }
          ],
          "source": "productcert@siemens.com"
        }
      ],
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:siemens-healthineers:syngo_fastview:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "B7D9A743-3BE4-4523-B34F-0C8461D3C63A",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        }
      ],
      "cveTags": [],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in syngo fastView (All versions). The affected application lacks proper validation of user-supplied data when parsing BMP files. This could result in an out-of-bounds write past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-14860)"
        },
        {
          "lang": "es",
          "value": "Se ha identificado una vulnerabilidad en syngo fastView (todas las versiones). La aplicaci\u00f3n afectada carece de una validaci\u00f3n adecuada de los datos proporcionados por el usuario al analizar archivos BMP. Esto podr\u00eda dar como resultado una escritura fuera de los l\u00edmites m\u00e1s all\u00e1 del final de una estructura asignada. Un atacante podr\u00eda aprovechar esta vulnerabilidad para ejecutar c\u00f3digo en el contexto del proceso actual. (ZDI-CAN-14860)"
        }
      ],
      "id": "CVE-2021-42028",
      "lastModified": "2026-06-17T04:09:12.090",
      "metrics": {
        "cvssMetricV31": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "LOCAL",
              "availabilityImpact": "HIGH",
              "baseScore": 7.8,
              "baseSeverity": "HIGH",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "REQUIRED",
              "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
              "version": "3.1"
            },
            "exploitabilityScore": 1.8,
            "impactScore": 5.9,
            "source": "productcert@siemens.com",
            "type": "Secondary"
          },
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "LOCAL",
              "availabilityImpact": "HIGH",
              "baseScore": 7.8,
              "baseSeverity": "HIGH",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "REQUIRED",
              "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
              "version": "3.1"
            },
            "exploitabilityScore": 1.8,
            "impactScore": 5.9,
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ],
        "ssvcV203": [
          {
            "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
            "ssvcData": {
              "id": "CVE-2021-42028",
              "options": [
                {
                  "exploitation": "none"
                },
                {
                  "automatable": "no"
                },
                {
                  "technicalImpact": "total"
                }
              ],
              "role": "CISA Coordinator",
              "timestamp": "2024-01-10T17:59:28.702254Z",
              "version": "2.0.3"
            }
          }
        ]
      },
      "published": "2024-01-04T12:15:23.250",
      "references": [
        {
          "source": "productcert@siemens.com",
          "tags": [
            "Vendor Advisory"
          ],
          "url": "https://www.siemens-healthineers.com/en-us/support-documentation/cybersecurity/shsa-688797"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Vendor Advisory"
          ],
          "url": "https://www.siemens-healthineers.com/en-us/support-documentation/cybersecurity/shsa-688797"
        }
      ],
      "sourceIdentifier": "productcert@siemens.com",
      "vulnStatus": "Modified",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-787"
            }
          ],
          "source": "productcert@siemens.com",
          "type": "Secondary"
        }
      ]
    }

    FKIE_CVE-2021-40367

    Vulnerability from fkie_nvd - Published: 2024-01-04 12:15 - Updated: 2026-06-17 04:06
    Summary
    A vulnerability has been identified in syngo fastView (All versions). The affected application lacks proper validation of user-supplied data when parsing DICOM files. This could result in an out-of-bounds write past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-15097)
    Impacted products
    Vendor Product Version
    siemens-healthineers syngo_fastview *

    {
      "affected": [
        {
          "affectedData": [
            {
              "defaultStatus": "unknown",
              "product": "syngo fastView",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions"
                }
              ]
            }
          ],
          "source": "productcert@siemens.com"
        }
      ],
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:siemens-healthineers:syngo_fastview:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "B7D9A743-3BE4-4523-B34F-0C8461D3C63A",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        }
      ],
      "cveTags": [],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in syngo fastView (All versions). The affected application lacks proper validation of user-supplied data when parsing DICOM files. This could result in an out-of-bounds write past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-15097)"
        },
        {
          "lang": "es",
          "value": "Se ha identificado una vulnerabilidad en syngo fastView (todas las versiones). La aplicaci\u00f3n afectada carece de una validaci\u00f3n adecuada de los datos proporcionados por el usuario al analizar archivos DICOM. Esto podr\u00eda dar como resultado una escritura fuera de los l\u00edmites m\u00e1s all\u00e1 del final de una estructura asignada. Un atacante podr\u00eda aprovechar esta vulnerabilidad para ejecutar c\u00f3digo en el contexto del proceso actual. (ZDI-CAN-15097)"
        }
      ],
      "id": "CVE-2021-40367",
      "lastModified": "2026-06-17T04:06:48.673",
      "metrics": {
        "cvssMetricV31": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "LOCAL",
              "availabilityImpact": "HIGH",
              "baseScore": 7.8,
              "baseSeverity": "HIGH",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "REQUIRED",
              "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
              "version": "3.1"
            },
            "exploitabilityScore": 1.8,
            "impactScore": 5.9,
            "source": "productcert@siemens.com",
            "type": "Secondary"
          },
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "LOCAL",
              "availabilityImpact": "HIGH",
              "baseScore": 7.8,
              "baseSeverity": "HIGH",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "REQUIRED",
              "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
              "version": "3.1"
            },
            "exploitabilityScore": 1.8,
            "impactScore": 5.9,
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ],
        "ssvcV203": [
          {
            "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
            "ssvcData": {
              "id": "CVE-2021-40367",
              "options": [
                {
                  "exploitation": "none"
                },
                {
                  "automatable": "no"
                },
                {
                  "technicalImpact": "total"
                }
              ],
              "role": "CISA Coordinator",
              "timestamp": "2024-01-10T18:28:18.046727Z",
              "version": "2.0.3"
            }
          }
        ]
      },
      "published": "2024-01-04T12:15:22.830",
      "references": [
        {
          "source": "productcert@siemens.com",
          "tags": [
            "Vendor Advisory"
          ],
          "url": "https://www.siemens-healthineers.com/en-us/support-documentation/cybersecurity/shsa-688797"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Vendor Advisory"
          ],
          "url": "https://www.siemens-healthineers.com/en-us/support-documentation/cybersecurity/shsa-688797"
        }
      ],
      "sourceIdentifier": "productcert@siemens.com",
      "vulnStatus": "Modified",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-787"
            }
          ],
          "source": "productcert@siemens.com",
          "type": "Secondary"
        }
      ]
    }

    CVE-2021-45465 (GCVE-0-2021-45465)

    Vulnerability from nvd – Published: 2024-01-04 11:20 – Updated: 2025-06-03 14:42
    VLAI
    Summary
    A vulnerability has been identified in syngo fastView (All versions). The affected application lacks proper validation of user-supplied data when parsing BMP files. This could result in a write-what-where condition and an attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-15696)
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2025-05-08 15:48 UTC
    CWE
    • CWE-123 - Write-what-where Condition
    Assigner
    siemens CNA under the icscert root
    CNA scorecard C 65/100 over 88 records in the last 180 days details
    Impacted products
    Vendor Product Version
    Siemens syngo fastView Affected: All versions
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T04:39:21.158Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.siemens-healthineers.com/en-us/support-documentation/cybersecurity/shsa-688797"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2021-45465",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-05-08T15:48:11.356596Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-06-03T14:42:42.914Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unknown",
              "product": "syngo fastView",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability has been identified in syngo fastView (All versions). The affected application lacks proper validation of user-supplied data when parsing BMP files. This could result in a write-what-where condition and an attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-15696)"
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "baseScore": 7.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:U/RC:C",
                "version": "3.1"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-123",
                  "description": "CWE-123: Write-what-where Condition",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-01-04T11:20:45.312Z",
            "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
            "shortName": "siemens"
          },
          "references": [
            {
              "url": "https://www.siemens-healthineers.com/en-us/support-documentation/cybersecurity/shsa-688797"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "assignerShortName": "siemens",
        "cveId": "CVE-2021-45465",
        "datePublished": "2024-01-04T11:20:18.660Z",
        "dateReserved": "2021-12-23T14:41:18.929Z",
        "dateUpdated": "2025-06-03T14:42:42.914Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2021-42028 (GCVE-0-2021-42028)

    Vulnerability from nvd – Published: 2024-01-04 11:20 – Updated: 2025-06-17 20:29
    VLAI
    Summary
    A vulnerability has been identified in syngo fastView (All versions). The affected application lacks proper validation of user-supplied data when parsing BMP files. This could result in an out-of-bounds write past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-14860)
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2024-01-10 17:59 UTC
    CWE
    Assigner
    siemens CNA under the icscert root
    CNA scorecard C 65/100 over 88 records in the last 180 days details
    Impacted products
    Vendor Product Version
    Siemens syngo fastView Affected: All versions
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T03:22:25.655Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.siemens-healthineers.com/en-us/support-documentation/cybersecurity/shsa-688797"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2021-42028",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-01-10T17:59:28.702254Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-06-17T20:29:09.233Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unknown",
              "product": "syngo fastView",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability has been identified in syngo fastView (All versions). The affected application lacks proper validation of user-supplied data when parsing BMP files. This could result in an out-of-bounds write past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-14860)"
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "baseScore": 7.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:U/RC:C",
                "version": "3.1"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-787",
                  "description": "CWE-787: Out-of-bounds Write",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-01-04T11:20:44.093Z",
            "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
            "shortName": "siemens"
          },
          "references": [
            {
              "url": "https://www.siemens-healthineers.com/en-us/support-documentation/cybersecurity/shsa-688797"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "assignerShortName": "siemens",
        "cveId": "CVE-2021-42028",
        "datePublished": "2024-01-04T11:20:17.462Z",
        "dateReserved": "2021-10-06T14:16:44.689Z",
        "dateUpdated": "2025-06-17T20:29:09.233Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2021-40367 (GCVE-0-2021-40367)

    Vulnerability from nvd – Published: 2024-01-04 11:20 – Updated: 2025-06-17 20:29
    VLAI
    Summary
    A vulnerability has been identified in syngo fastView (All versions). The affected application lacks proper validation of user-supplied data when parsing DICOM files. This could result in an out-of-bounds write past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-15097)
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2024-01-10 18:28 UTC
    CWE
    Assigner
    siemens CNA under the icscert root
    CNA scorecard C 65/100 over 88 records in the last 180 days details
    Impacted products
    Vendor Product Version
    Siemens syngo fastView Affected: All versions
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T02:44:09.548Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.siemens-healthineers.com/en-us/support-documentation/cybersecurity/shsa-688797"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2021-40367",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-01-10T18:28:18.046727Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-06-17T20:29:09.030Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unknown",
              "product": "syngo fastView",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability has been identified in syngo fastView (All versions). The affected application lacks proper validation of user-supplied data when parsing DICOM files. This could result in an out-of-bounds write past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-15097)"
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "baseScore": 7.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:U/RC:C",
                "version": "3.1"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-787",
                  "description": "CWE-787: Out-of-bounds Write",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-01-04T11:20:42.887Z",
            "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
            "shortName": "siemens"
          },
          "references": [
            {
              "url": "https://www.siemens-healthineers.com/en-us/support-documentation/cybersecurity/shsa-688797"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "assignerShortName": "siemens",
        "cveId": "CVE-2021-40367",
        "datePublished": "2024-01-04T11:20:42.887Z",
        "dateReserved": "2021-09-01T10:41:17.478Z",
        "dateUpdated": "2025-06-17T20:29:09.030Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2021-40367 (GCVE-0-2021-40367)

    Vulnerability from cvelistv5 – Published: 2024-01-04 11:20 – Updated: 2025-06-17 20:29
    VLAI
    Summary
    A vulnerability has been identified in syngo fastView (All versions). The affected application lacks proper validation of user-supplied data when parsing DICOM files. This could result in an out-of-bounds write past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-15097)
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2024-01-10 18:28 UTC
    CWE
    Assigner
    siemens CNA under the icscert root
    CNA scorecard C 65/100 over 88 records in the last 180 days details
    Impacted products
    Vendor Product Version
    Siemens syngo fastView Affected: All versions
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T02:44:09.548Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.siemens-healthineers.com/en-us/support-documentation/cybersecurity/shsa-688797"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2021-40367",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-01-10T18:28:18.046727Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-06-17T20:29:09.030Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unknown",
              "product": "syngo fastView",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability has been identified in syngo fastView (All versions). The affected application lacks proper validation of user-supplied data when parsing DICOM files. This could result in an out-of-bounds write past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-15097)"
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "baseScore": 7.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:U/RC:C",
                "version": "3.1"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-787",
                  "description": "CWE-787: Out-of-bounds Write",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-01-04T11:20:42.887Z",
            "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
            "shortName": "siemens"
          },
          "references": [
            {
              "url": "https://www.siemens-healthineers.com/en-us/support-documentation/cybersecurity/shsa-688797"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "assignerShortName": "siemens",
        "cveId": "CVE-2021-40367",
        "datePublished": "2024-01-04T11:20:42.887Z",
        "dateReserved": "2021-09-01T10:41:17.478Z",
        "dateUpdated": "2025-06-17T20:29:09.030Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2021-45465 (GCVE-0-2021-45465)

    Vulnerability from cvelistv5 – Published: 2024-01-04 11:20 – Updated: 2025-06-03 14:42
    VLAI
    Summary
    A vulnerability has been identified in syngo fastView (All versions). The affected application lacks proper validation of user-supplied data when parsing BMP files. This could result in a write-what-where condition and an attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-15696)
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2025-05-08 15:48 UTC
    CWE
    • CWE-123 - Write-what-where Condition
    Assigner
    siemens CNA under the icscert root
    CNA scorecard C 65/100 over 88 records in the last 180 days details
    Impacted products
    Vendor Product Version
    Siemens syngo fastView Affected: All versions
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T04:39:21.158Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.siemens-healthineers.com/en-us/support-documentation/cybersecurity/shsa-688797"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2021-45465",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-05-08T15:48:11.356596Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-06-03T14:42:42.914Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unknown",
              "product": "syngo fastView",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability has been identified in syngo fastView (All versions). The affected application lacks proper validation of user-supplied data when parsing BMP files. This could result in a write-what-where condition and an attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-15696)"
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "baseScore": 7.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:U/RC:C",
                "version": "3.1"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-123",
                  "description": "CWE-123: Write-what-where Condition",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-01-04T11:20:45.312Z",
            "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
            "shortName": "siemens"
          },
          "references": [
            {
              "url": "https://www.siemens-healthineers.com/en-us/support-documentation/cybersecurity/shsa-688797"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "assignerShortName": "siemens",
        "cveId": "CVE-2021-45465",
        "datePublished": "2024-01-04T11:20:18.660Z",
        "dateReserved": "2021-12-23T14:41:18.929Z",
        "dateUpdated": "2025-06-03T14:42:42.914Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2021-42028 (GCVE-0-2021-42028)

    Vulnerability from cvelistv5 – Published: 2024-01-04 11:20 – Updated: 2025-06-17 20:29
    VLAI
    Summary
    A vulnerability has been identified in syngo fastView (All versions). The affected application lacks proper validation of user-supplied data when parsing BMP files. This could result in an out-of-bounds write past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-14860)
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2024-01-10 17:59 UTC
    CWE
    Assigner
    siemens CNA under the icscert root
    CNA scorecard C 65/100 over 88 records in the last 180 days details
    Impacted products
    Vendor Product Version
    Siemens syngo fastView Affected: All versions
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T03:22:25.655Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.siemens-healthineers.com/en-us/support-documentation/cybersecurity/shsa-688797"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2021-42028",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-01-10T17:59:28.702254Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-06-17T20:29:09.233Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unknown",
              "product": "syngo fastView",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability has been identified in syngo fastView (All versions). The affected application lacks proper validation of user-supplied data when parsing BMP files. This could result in an out-of-bounds write past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-14860)"
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "baseScore": 7.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:U/RC:C",
                "version": "3.1"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-787",
                  "description": "CWE-787: Out-of-bounds Write",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-01-04T11:20:44.093Z",
            "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
            "shortName": "siemens"
          },
          "references": [
            {
              "url": "https://www.siemens-healthineers.com/en-us/support-documentation/cybersecurity/shsa-688797"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "assignerShortName": "siemens",
        "cveId": "CVE-2021-42028",
        "datePublished": "2024-01-04T11:20:17.462Z",
        "dateReserved": "2021-10-06T14:16:44.689Z",
        "dateUpdated": "2025-06-17T20:29:09.233Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }