    3 vulnerabilities found for smx_series_23_ups_firmware by schneider-electric

    FKIE_CVE-2022-0715

    Vulnerability from fkie_nvd - Published: 2022-03-09 20:15 - Updated: 2026-06-17 04:21
    Summary
    A CWE-287: Improper Authentication vulnerability exists that could cause an attacker to arbitrarily change the behavior of the UPS when a key is leaked and used to upload malicious firmware. Affected Product: APC Smart-UPS Family: SMT Series (SMT Series ID=18: UPS 09.8 and prior / SMT Series ID=1040: UPS 01.2 and prior / SMT Series ID=1031: UPS 03.1 and prior), SMC Series (SMC Series ID=1005: UPS 14.1 and prior / SMC Series ID=1007: UPS 11.0 and prior / SMC Series ID=1041: UPS 01.1 and prior), SCL Series (SCL Series ID=1030: UPS 02.5 and prior / SCL Series ID=1036: UPS 02.5 and prior), SMX Series (SMX Series ID=20: UPS 10.2 and prior / SMX Series ID=23: UPS 07.0 and prior), SRT Series (SRT Series ID=1010/1019/1025: UPS 08.3 and prior / SRT Series ID=1024: UPS 01.0 and prior / SRT Series ID=1020: UPS 10.4 and prior / SRT Series ID=1021: UPS 12.2 and prior / SRT Series ID=1001/1013: UPS 05.1 and prior / SRT Series ID=1002/1014: UPSa05.2 and prior), APC SmartConnect Family: SMT Series (SMT Series ID=1015: UPS 04.5 and prior), SMC Series (SMC Series ID=1018: UPS 04.2 and prior), SMTL Series (SMTL Series ID=1026: UPS 02.9 and prior), SCL Series (SCL Series ID=1029: UPS 02.5 and prior / SCL Series ID=1030: UPS 02.5 and prior / SCL Series ID=1036: UPS 02.5 and prior / SCL Series ID=1037: UPS 03.1 and prior), SMX Series (SMX Series ID=1031: UPS 03.1 and prior)
    Impacted products
    Vendor Product Version
    schneider-electric smt_series_1015_ups_firmware *
    schneider-electric smt_series_1015_ups -
    schneider-electric smc_series_1018_ups_firmware *
    schneider-electric smc_series_1018_ups -
    schneider-electric smtl_series_1026_ups_firmware *
    schneider-electric smtl_series_1026_ups -
    schneider-electric scl_series_1029_ups_firmware *
    schneider-electric scl_series_1029_ups -
    schneider-electric scl_series_1030_ups_firmware *
    schneider-electric scl_series_1030_ups -
    schneider-electric scl_series_1036_ups_firmware *
    schneider-electric scl_series_1036_ups -
    schneider-electric scl_series_1037_ups_firmware *
    schneider-electric scl_series_1037_ups -
    schneider-electric smx_series_1031_ups_firmware *
    schneider-electric smx_series_1031_ups -
    schneider-electric smt_series_18_ups_firmware *
    schneider-electric smt_series_18_ups -
    schneider-electric smt_series_1040_ups_firmware *
    schneider-electric smt_series_1040_ups -
    schneider-electric smt_series_1031_ups_firmware *
    schneider-electric smt_series_1031_ups -
    schneider-electric smc_series_1005_ups_firmware *
    schneider-electric smc_series_1005_ups -
    schneider-electric smc_series_1007_ups_firmware *
    schneider-electric smc_series_1007_ups -
    schneider-electric smc_series_1041_ups_firmware *
    schneider-electric smc_series_1041_ups -
    schneider-electric scl_series_1030_ups_firmware *
    schneider-electric scl_series_1030_ups -
    schneider-electric scl_series_1036_ups_firmware *
    schneider-electric scl_series_1036_ups -
    schneider-electric smx_series_20_ups_firmware *
    schneider-electric smx_series_20_ups -
    schneider-electric smx_series_23_ups_firmware *
    schneider-electric smx_series_23_ups -
    schneider-electric srt_series_1010_ups_firmware *
    schneider-electric srt_series_1010_ups -
    schneider-electric srt_series_1019_ups_firmware *
    schneider-electric srt_series_1019_ups -
    schneider-electric srt_series_1025_ups_firmware *
    schneider-electric srt_series_1025_ups -
    schneider-electric srt_series_1020_ups_firmware *
    schneider-electric srt_series_1020_ups -
    schneider-electric srt_series_1021_ups_firmware *
    schneider-electric srt_series_1021_ups -
    schneider-electric srt_series_1001_ups_firmware *
    schneider-electric srt_series_1001_ups -
    schneider-electric srt_series_1013_ups_firmware *
    schneider-electric srt_series_1013_ups -
    schneider-electric srt_series_1002_ups_firmware *
    schneider-electric srt_series_1002_ups -
    schneider-electric srt_series_1014_ups_firmware *
    schneider-electric srt_series_1014_ups -
    schneider-electric srtl1000rmxli_firmware *
    schneider-electric srtl1000rmxli -
    schneider-electric srtl1000rmxli-nc_firmware *
    schneider-electric srtl1000rmxli-nc -
    schneider-electric srtl1500rmxli-nc_firmware *
    schneider-electric srtl1500rmxli-nc -
    schneider-electric srtl1500rmxli_firmware *
    schneider-electric srtl1500rmxli -
    schneider-electric srtl2200rmxli_firmware *
    schneider-electric srtl2200rmxli -
    schneider-electric srtl2200rmxli-nc_firmware *
    schneider-electric srtl2200rmxli-nc -
    schneider-electric srtl3000rmxli-nc_firmware *
    schneider-electric srtl3000rmxli-nc -
    schneider-electric srtl3000rmxli_firmware *
    schneider-electric srtl3000rmxli -

    {
      "affected": [
        {
          "affectedData": [
            {
              "product": "APC Smart-UPS",
              "vendor": "Schneider Electric",
              "versions": [
                {
                  "status": "affected",
                  "version": "SMT Series"
                },
                {
                  "status": "affected",
                  "version": "SMC Series"
                },
                {
                  "status": "affected",
                  "version": "SCL Series"
                },
                {
                  "status": "affected",
                  "version": "SMX Series"
                },
                {
                  "status": "affected",
                  "version": "SRT Series"
                }
              ]
            },
            {
              "product": "SmartConnect",
              "vendor": "Schneider Electric",
              "versions": [
                {
                  "status": "affected",
                  "version": "SMT Series"
                },
                {
                  "status": "affected",
                  "version": "SMC Series"
                },
                {
                  "status": "affected",
                  "version": "SMTL Series"
                },
                {
                  "status": "affected",
                  "version": "SCL Series"
                },
                {
                  "status": "affected",
                  "version": "SMX Series"
                }
              ]
            }
          ],
          "source": "cybersecurity@se.com"
        }
      ],
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:schneider-electric:smt_series_1015_ups_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "2C3EA55B-DB09-4124-A9D9-A92431C38D1F",
                  "versionEndIncluding": "04.5",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:schneider-electric:smt_series_1015_ups:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "95C1E3D9-606B-4C57-A4E7-0A45C9D46332",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:schneider-electric:smc_series_1018_ups_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "FFE2D844-ED18-44D3-9E75-4BB3082E4B51",
                  "versionEndIncluding": "04.2",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:schneider-electric:smc_series_1018_ups:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "154E788E-173C-4D16-A492-B61D39D420EF",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:schneider-electric:smtl_series_1026_ups_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "AE693F05-B0A7-452D-94C6-D36E37ACF6CB",
                  "versionEndIncluding": "02.9",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:schneider-electric:smtl_series_1026_ups:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "6B138EB4-6264-4BFA-B4C7-4B23FFA676B1",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:schneider-electric:scl_series_1029_ups_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "C2E0803A-637E-4BBA-B9D5-AB59EE122844",
                  "versionEndIncluding": "02.5",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:schneider-electric:scl_series_1029_ups:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "4175BEC7-DA4D-4E19-A642-A5FC13D3598E",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:schneider-electric:scl_series_1030_ups_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "469F9813-DE0E-4752-91EB-FECC001C6825",
                  "versionEndIncluding": "02.5",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:schneider-electric:scl_series_1030_ups:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "E8DC43CB-66C0-469B-AF87-0120D6280584",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:schneider-electric:scl_series_1036_ups_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "22E4C951-876D-46F7-8CF4-D943464E8338",
                  "versionEndIncluding": "02.5",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:schneider-electric:scl_series_1036_ups:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "9FB7E0EB-AF6D-4107-B343-50309E9DF03E",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:schneider-electric:scl_series_1037_ups_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "3E52A522-88D4-4B6A-83B4-C56C093C7F54",
                  "versionEndIncluding": "03.1",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:schneider-electric:scl_series_1037_ups:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "04C627CE-E3F8-4E3F-8B93-07C92AA21296",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:schneider-electric:smx_series_1031_ups_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "6251AE4E-FFED-4B0C-A90B-A3BD852A2ED8",
                  "versionEndIncluding": "03.1",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:schneider-electric:smx_series_1031_ups:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "9E1E7040-8123-483C-AE62-F190D83D0ADC",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:schneider-electric:smt_series_18_ups_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "A9B1431D-822C-47DF-8643-7D5E778A43AD",
                  "versionEndIncluding": "09.8",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:schneider-electric:smt_series_18_ups:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "0E1F03F0-11F1-437A-8FD8-A3C8186D02DE",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:schneider-electric:smt_series_1040_ups_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "660A5F99-3370-48C9-A3C8-A54FFAC9BEE6",
                  "versionEndIncluding": "01.2",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:schneider-electric:smt_series_1040_ups:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "848020CF-D33A-4196-BB0C-ECD1D43372D7",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:schneider-electric:smt_series_1031_ups_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "CE801653-57F9-4C13-8D23-91D5F22FD2C9",
                  "versionEndIncluding": "03.1",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:schneider-electric:smt_series_1031_ups:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "E1467655-7784-4287-8C32-3F522A49411D",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:schneider-electric:smc_series_1005_ups_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "1B5D15FE-D25F-4827-99C2-2B15DA5726F3",
                  "versionEndIncluding": "14.1",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:schneider-electric:smc_series_1005_ups:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "26B5EC8E-4FF9-4ED0-AB70-B5F6DBA72632",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:schneider-electric:smc_series_1007_ups_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "4929654C-D91D-4228-807B-F9DAC9D8C931",
                  "versionEndIncluding": "11.0",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:schneider-electric:smc_series_1007_ups:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "2761A47B-326E-4CD0-96D6-12796992769D",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:schneider-electric:smc_series_1041_ups_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "428CBB13-0227-4557-8A22-DE8165949D3B",
                  "versionEndIncluding": "01.1",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:schneider-electric:smc_series_1041_ups:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "7FEFAD29-12AD-454B-BAFC-4C17A1D1E8E1",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:schneider-electric:scl_series_1030_ups_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "469F9813-DE0E-4752-91EB-FECC001C6825",
                  "versionEndIncluding": "02.5",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:schneider-electric:scl_series_1030_ups:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "E8DC43CB-66C0-469B-AF87-0120D6280584",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:schneider-electric:scl_series_1036_ups_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "22E4C951-876D-46F7-8CF4-D943464E8338",
                  "versionEndIncluding": "02.5",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:schneider-electric:scl_series_1036_ups:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "9FB7E0EB-AF6D-4107-B343-50309E9DF03E",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:schneider-electric:smx_series_20_ups_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "49A9A0AA-9E54-426D-B3DF-A896119DCFCB",
                  "versionEndIncluding": "10.2",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:schneider-electric:smx_series_20_ups:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "9869EFE8-DED1-40D9-8BD6-003E0507995F",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:schneider-electric:smx_series_23_ups_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "AD04C6BF-A05F-41DC-9DB8-6ECBEF570FA3",
                  "versionEndIncluding": "07.0",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:schneider-electric:smx_series_23_ups:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "A58B76AA-7DFC-4F6C-B6E6-4B19746788B3",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:schneider-electric:srt_series_1010_ups_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "6717F4F6-F033-48CB-A4BA-6E19DAD98FE5",
                  "versionEndIncluding": "08.3",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:schneider-electric:srt_series_1010_ups:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "83769E66-3290-4559-AD5A-C65BE83B27A1",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:schneider-electric:srt_series_1019_ups_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "A45A70DF-4794-4E45-B134-EB8435AC5FB8",
                  "versionEndIncluding": "08.3",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:schneider-electric:srt_series_1019_ups:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "09A53A75-F08A-47E9-A3CF-691EE7B475B7",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:schneider-electric:srt_series_1025_ups_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "B73BB6AE-8CC4-465F-9C48-B125D0C25F59",
                  "versionEndIncluding": "08.3",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:schneider-electric:srt_series_1025_ups:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "D883C4EF-0530-4E8B-8C83-57B452219687",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:schneider-electric:srt_series_1020_ups_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "CC69A97E-D632-42FE-A217-572EB966085A",
                  "versionEndIncluding": "10.4",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:schneider-electric:srt_series_1020_ups:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "94F049E9-F1D2-4006-9C9A-5DA9C7229087",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:schneider-electric:srt_series_1021_ups_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "CF0C5ED3-2100-48C1-AC5A-E6285487815D",
                  "versionEndIncluding": "12.2",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:schneider-electric:srt_series_1021_ups:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "DEC3AD24-6B13-4A44-A58C-9189BCF480D4",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:schneider-electric:srt_series_1001_ups_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "1D4D6B50-3B1A-47EF-9055-2887128F0224",
                  "versionEndIncluding": "05.1",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:schneider-electric:srt_series_1001_ups:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "EB599BB4-82F4-4E97-BEF5-0ECC587F0A68",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:schneider-electric:srt_series_1013_ups_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "B4B35543-73E5-4EDD-9018-3BE90A5B99C5",
                  "versionEndIncluding": "05.1",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:schneider-electric:srt_series_1013_ups:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "833DCA70-FCBA-4C58-80EE-DEFFD0F661EF",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:schneider-electric:srt_series_1002_ups_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "318BBEA4-EAF2-499A-8E89-39EC58781BA6",
                  "versionEndIncluding": "a05.2",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:schneider-electric:srt_series_1002_ups:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "20C49E94-8D0A-4202-A433-6787BF8E4B68",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:schneider-electric:srt_series_1014_ups_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "043062A8-6D85-46CD-934F-82BF075B8D53",
                  "versionEndIncluding": "a05.2",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:schneider-electric:srt_series_1014_ups:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "B55E3932-EBCF-44CA-930D-F254EFF5FC68",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:schneider-electric:srtl1000rmxli_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "4A9B5DEA-467F-4C36-854A-F7A5967F0BD1",
                  "versionEndIncluding": "01.0",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:schneider-electric:srtl1000rmxli:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "5165586B-64EF-4E2C-B496-2E82A61113A4",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:schneider-electric:srtl1000rmxli-nc_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "FD635E09-A358-422A-9BD0-2B177D98E3EE",
                  "versionEndIncluding": "01.0",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:schneider-electric:srtl1000rmxli-nc:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "13699C09-1AB8-4C43-9621-295413A974FF",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:schneider-electric:srtl1500rmxli-nc_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "1A5732D4-6BBD-41CA-8D24-84F2FC1412AC",
                  "versionEndIncluding": "01.0",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:schneider-electric:srtl1500rmxli-nc:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "773C3D26-4C71-440E-8CCA-85478C59B247",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:schneider-electric:srtl1500rmxli_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "ECDE919A-70ED-411B-9AAA-12C8B9EB1785",
                  "versionEndIncluding": "01.0",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:schneider-electric:srtl1500rmxli:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "C418AEA1-3C77-4969-9651-9995F7DE99EA",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:schneider-electric:srtl2200rmxli_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "40D232F8-B3F7-4CCF-9E08-6EA63AD7596C",
                  "versionEndIncluding": "01.0",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:schneider-electric:srtl2200rmxli:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "7883EDB6-5A6D-4CDF-A467-A46E522B3B22",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:schneider-electric:srtl2200rmxli-nc_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "EB73EFDD-0994-4553-9075-5EB390816B31",
                  "versionEndIncluding": "01.0",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:schneider-electric:srtl2200rmxli-nc:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "54F5A2E5-DA9A-412E-A5FF-9EA97A8A2D9F",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:schneider-electric:srtl3000rmxli-nc_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "66BFDC2B-B658-4782-AB42-14978BFD2ECC",
                  "versionEndIncluding": "01.0",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:schneider-electric:srtl3000rmxli-nc:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "5FE692C1-4995-430A-896E-BDD68325BD16",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:schneider-electric:srtl3000rmxli_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "83E06F71-7148-4B01-913C-5D92AA36C499",
                  "versionEndIncluding": "01.0",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:schneider-electric:srtl3000rmxli:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "42A83199-87D4-4DD2-854F-2EDBD09509C4",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        }
      ],
      "cveTags": [],
      "descriptions": [
        {
          "lang": "en",
          "value": "A CWE-287: Improper Authentication vulnerability exists that could cause an attacker to arbitrarily change the behavior of the UPS when a key is leaked and used to upload malicious firmware. Affected Product: APC Smart-UPS Family: SMT Series (SMT Series ID=18: UPS 09.8 and prior / SMT Series ID=1040: UPS 01.2 and prior / SMT Series ID=1031: UPS 03.1 and prior), SMC Series (SMC Series ID=1005: UPS 14.1 and prior / SMC Series ID=1007: UPS 11.0 and prior / SMC Series ID=1041: UPS 01.1 and prior), SCL Series (SCL Series ID=1030: UPS 02.5 and prior / SCL Series ID=1036: UPS 02.5 and prior), SMX Series (SMX Series ID=20: UPS 10.2 and prior / SMX Series ID=23: UPS 07.0 and prior), SRT Series (SRT Series ID=1010/1019/1025: UPS 08.3 and prior / SRT Series ID=1024: UPS 01.0 and prior / SRT Series ID=1020: UPS 10.4 and prior / SRT Series ID=1021: UPS 12.2 and prior / SRT Series ID=1001/1013: UPS 05.1 and prior / SRT Series ID=1002/1014: UPSa05.2 and prior), APC SmartConnect Family: SMT Series (SMT Series ID=1015: UPS 04.5 and prior), SMC Series (SMC Series ID=1018: UPS 04.2 and prior), SMTL Series (SMTL Series ID=1026: UPS 02.9 and prior), SCL Series (SCL Series ID=1029: UPS 02.5 and prior / SCL Series ID=1030: UPS 02.5 and prior / SCL Series ID=1036: UPS 02.5 and prior / SCL Series ID=1037: UPS 03.1 and prior), SMX Series (SMX Series ID=1031: UPS 03.1 and prior)"
        },
        {
          "lang": "es",
          "value": "Una CWE-287: Se presenta una vulnerabilidad de autenticaci\u00f3n inapropiada que podr\u00eda causar que un atacante cambie arbitrariamente el comportamiento del SAI cuando es filtrada una clave y es usada para cargar firmware malicioso. Producto afectado: Familia de Smart-UPS de APC: Serie SMT (SMT Series ID=18: UPS versiones 09.8 y anteriores / SMT Series ID=1040: UPS versiones 01.2 y anteriores / SMT Series ID=1031: UPS versiones 03.1 y anteriores), SMC Series (SMC Series ID=1005: UPS versiones 14.1 y anteriores / SMC Series ID=1007: UPS versiones 11.0 y anteriores / SMC Series ID=1041: UPS versiones 01.1 y anteriores), SCL Series (SCL Series ID=1030: UPS versiones 02.5 y anteriores / SCL Series ID=1036: UPS versiones 02.5 y anteriores), SMX Series (SMX Series ID=20: UPS versiones 10.2 y anteriores / SMX Series ID=23: UPS versiones 07.0 y anteriores), SRT Series (SRT Series ID=1010/1019/1025: UPS versiones 08.3 y anteriores / SRT Series ID=1024: UPS versiones 01.0 y anteriores / SRT Series ID=1020: UPS versiones 10.4 y anteriores / SRT Series ID=1021: UPS versiones 12.2 y anteriores / SRT Series ID=1001/1013: UPS versiones 05.1 y anteriores / SRT Series ID=1002/1014: UPS versiones a05.2 y anteriores), Familia SmartConnect de APC: Serie SMT (Serie SMT ID=1015: UPS versiones 04.5 y anteriores), Serie SMC (Serie SMC ID=1018: UPS versiones 04.2 y anteriores), Serie SMTL (Serie SMTL ID=1026: UPS versiones 02.9 y anteriores), Serie SCL (Serie SCL ID=1029: UPS versiones 02.5 y anteriores / SCL Series ID=1030: UPS versiones 02.5 y anteriores / SCL Series ID=1036: UPS versiones 02.5 y anteriores / SCL Series ID=1037: UPS versiones 03.1 y anteriores), SMX Series (SMX Series ID=1031: UPS versiones 03.1 y anteriores)"
        }
      ],
      "id": "CVE-2022-0715",
      "lastModified": "2026-06-17T04:21:07.040",
      "metrics": {
        "cvssMetricV2": [
          {
            "acInsufInfo": false,
            "baseSeverity": "MEDIUM",
            "cvssData": {
              "accessComplexity": "LOW",
              "accessVector": "NETWORK",
              "authentication": "NONE",
              "availabilityImpact": "PARTIAL",
              "baseScore": 6.4,
              "confidentialityImpact": "NONE",
              "integrityImpact": "PARTIAL",
              "vectorString": "AV:N/AC:L/Au:N/C:N/I:P/A:P",
              "version": "2.0"
            },
            "exploitabilityScore": 10.0,
            "impactScore": 4.9,
            "obtainAllPrivilege": false,
            "obtainOtherPrivilege": false,
            "obtainUserPrivilege": false,
            "source": "nvd@nist.gov",
            "type": "Primary",
            "userInteractionRequired": false
          }
        ],
        "cvssMetricV31": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 9.1,
              "baseSeverity": "CRITICAL",
              "confidentialityImpact": "NONE",
              "integrityImpact": "HIGH",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:H",
              "version": "3.1"
            },
            "exploitabilityScore": 3.9,
            "impactScore": 5.2,
            "source": "nvd@nist.gov",
            "type": "Primary"
          },
          {
            "cvssData": {
              "attackComplexity": "HIGH",
              "attackVector": "NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 8.9,
              "baseSeverity": "HIGH",
              "confidentialityImpact": "LOW",
              "integrityImpact": "HIGH",
              "privilegesRequired": "NONE",
              "scope": "CHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:C/C:L/I:H/A:H",
              "version": "3.1"
            },
            "exploitabilityScore": 2.2,
            "impactScore": 6.0,
            "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
            "type": "Secondary"
          }
        ],
        "ssvcV203": [
          {
            "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
            "ssvcData": {
              "id": "CVE-2022-0715",
              "options": [
                {
                  "exploitation": "none"
                },
                {
                  "automatable": "no"
                },
                {
                  "technicalImpact": "partial"
                }
              ],
              "role": "CISA Coordinator",
              "timestamp": "2026-05-29T14:04:24.695082Z",
              "version": "2.0.3"
            }
          }
        ]
      },
      "published": "2022-03-09T20:15:08.300",
      "references": [
        {
          "source": "cybersecurity@se.com",
          "tags": [
            "Vendor Advisory"
          ],
          "url": "https://www.se.com/ww/en/download/document/SEVD-2022-067-02/"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Vendor Advisory"
          ],
          "url": "https://www.se.com/ww/en/download/document/SEVD-2022-067-02/"
        }
      ],
      "sourceIdentifier": "cybersecurity@se.com",
      "vulnStatus": "Modified",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-287"
            }
          ],
          "source": "cybersecurity@se.com",
          "type": "Secondary"
        },
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-345"
            }
          ],
          "source": "nvd@nist.gov",
          "type": "Primary"
        }
      ]
    }

    CVE-2022-0715 (GCVE-0-2022-0715)

    Vulnerability from nvd – Published: 2022-03-09 19:30 – Updated: 2026-05-29 14:05
    VLAI
    Summary
    A CWE-287: Improper Authentication vulnerability exists that could cause an attacker to arbitrarily change the behavior of the UPS when a key is leaked and used to upload malicious firmware. Affected Product: APC Smart-UPS Family: SMT Series (SMT Series ID=18: UPS 09.8 and prior / SMT Series ID=1040: UPS 01.2 and prior / SMT Series ID=1031: UPS 03.1 and prior), SMC Series (SMC Series ID=1005: UPS 14.1 and prior / SMC Series ID=1007: UPS 11.0 and prior / SMC Series ID=1041: UPS 01.1 and prior), SCL Series (SCL Series ID=1030: UPS 02.5 and prior / SCL Series ID=1036: UPS 02.5 and prior), SMX Series (SMX Series ID=20: UPS 10.2 and prior / SMX Series ID=23: UPS 07.0 and prior), SRT Series (SRT Series ID=1010/1019/1025: UPS 08.3 and prior / SRT Series ID=1024: UPS 01.0 and prior / SRT Series ID=1020: UPS 10.4 and prior / SRT Series ID=1021: UPS 12.2 and prior / SRT Series ID=1001/1013: UPS 05.1 and prior / SRT Series ID=1002/1014: UPSa05.2 and prior), APC SmartConnect Family: SMT Series (SMT Series ID=1015: UPS 04.5 and prior), SMC Series (SMC Series ID=1018: UPS 04.2 and prior), SMTL Series (SMTL Series ID=1026: UPS 02.9 and prior), SCL Series (SCL Series ID=1029: UPS 02.5 and prior / SCL Series ID=1030: UPS 02.5 and prior / SCL Series ID=1036: UPS 02.5 and prior / SCL Series ID=1037: UPS 03.1 and prior), SMX Series (SMX Series ID=1031: UPS 03.1 and prior)
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-05-29 14:04 UTC
    CWE
    • CWE-287 - Improper Authentication
    Assigner
    schneider CNA under the mitre root
    CNA scorecard C 65/100 over 20 records in the last 180 days details
    References
    Impacted products
    Vendor Product Version
    Schneider Electric APC Smart-UPS Affected: SMT Series
    Affected: SMC Series
    Affected: SCL Series
    Affected: SMX Series
    Affected: SRT Series
    Create a notification for this product.
    Schneider Electric SmartConnect Affected: SMT Series
    Affected: SMC Series
    Affected: SMTL Series
    Affected: SCL Series
    Affected: SMX Series
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T23:40:03.366Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.se.com/ww/en/download/document/SEVD-2022-067-02/"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "cvssV3_1": {
                  "attackComplexity": "HIGH",
                  "attackVector": "NETWORK",
                  "availabilityImpact": "HIGH",
                  "baseScore": 8.9,
                  "baseSeverity": "HIGH",
                  "confidentialityImpact": "LOW",
                  "integrityImpact": "HIGH",
                  "privilegesRequired": "NONE",
                  "scope": "CHANGED",
                  "userInteraction": "NONE",
                  "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:C/C:L/I:H/A:H",
                  "version": "3.1"
                }
              },
              {
                "other": {
                  "content": {
                    "id": "CVE-2022-0715",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-05-29T14:04:24.695082Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-05-29T14:05:59.422Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "APC Smart-UPS",
              "vendor": "Schneider Electric",
              "versions": [
                {
                  "status": "affected",
                  "version": "SMT Series"
                },
                {
                  "status": "affected",
                  "version": "SMC Series"
                },
                {
                  "status": "affected",
                  "version": "SCL Series"
                },
                {
                  "status": "affected",
                  "version": "SMX Series"
                },
                {
                  "status": "affected",
                  "version": "SRT Series"
                }
              ]
            },
            {
              "product": "SmartConnect",
              "vendor": "Schneider Electric",
              "versions": [
                {
                  "status": "affected",
                  "version": "SMT Series"
                },
                {
                  "status": "affected",
                  "version": "SMC Series"
                },
                {
                  "status": "affected",
                  "version": "SMTL Series"
                },
                {
                  "status": "affected",
                  "version": "SCL Series"
                },
                {
                  "status": "affected",
                  "version": "SMX Series"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A CWE-287: Improper Authentication vulnerability exists that could cause an attacker to arbitrarily change the behavior of the UPS when a key is leaked and used to upload malicious firmware. Affected Product: APC Smart-UPS Family: SMT Series (SMT Series ID=18: UPS 09.8 and prior / SMT Series ID=1040: UPS 01.2 and prior / SMT Series ID=1031: UPS 03.1 and prior), SMC Series (SMC Series ID=1005: UPS 14.1 and prior / SMC Series ID=1007: UPS 11.0 and prior / SMC Series ID=1041: UPS 01.1 and prior), SCL Series (SCL Series ID=1030: UPS 02.5 and prior / SCL Series ID=1036: UPS 02.5 and prior), SMX Series (SMX Series ID=20: UPS 10.2 and prior / SMX Series ID=23: UPS 07.0 and prior), SRT Series (SRT Series ID=1010/1019/1025: UPS 08.3 and prior / SRT Series ID=1024: UPS 01.0 and prior / SRT Series ID=1020: UPS 10.4 and prior / SRT Series ID=1021: UPS 12.2 and prior / SRT Series ID=1001/1013: UPS 05.1 and prior / SRT Series ID=1002/1014: UPSa05.2 and prior), APC SmartConnect Family: SMT Series (SMT Series ID=1015: UPS 04.5 and prior), SMC Series (SMC Series ID=1018: UPS 04.2 and prior), SMTL Series (SMTL Series ID=1026: UPS 02.9 and prior), SCL Series (SCL Series ID=1029: UPS 02.5 and prior / SCL Series ID=1030: UPS 02.5 and prior / SCL Series ID=1036: UPS 02.5 and prior / SCL Series ID=1037: UPS 03.1 and prior), SMX Series (SMX Series ID=1031: UPS 03.1 and prior)"
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-287",
                  "description": "CWE-287 Improper Authentication",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2022-03-28T16:25:27.000Z",
            "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
            "shortName": "schneider"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.se.com/ww/en/download/document/SEVD-2022-067-02/"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "x_generator": {
            "engine": "Vulnogram 0.0.9"
          },
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cybersecurity@schneider-electric.com",
              "ID": "CVE-2022-0715",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "APC Smart-UPS",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "SMT Series"
                              },
                              {
                                "version_value": "SMC Series"
                              },
                              {
                                "version_value": "SCL Series"
                              },
                              {
                                "version_value": "SMX Series"
                              },
                              {
                                "version_value": "SRT Series"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "SmartConnect",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "SMT Series"
                              },
                              {
                                "version_value": "SMC Series"
                              },
                              {
                                "version_value": "SMTL Series"
                              },
                              {
                                "version_value": "SCL Series"
                              },
                              {
                                "version_value": "SMX Series"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "Schneider Electric"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "A CWE-287: Improper Authentication vulnerability exists that could cause an attacker to arbitrarily change the behavior of the UPS when a key is leaked and used to upload malicious firmware. Affected Product: APC Smart-UPS Family: SMT Series (SMT Series ID=18: UPS 09.8 and prior / SMT Series ID=1040: UPS 01.2 and prior / SMT Series ID=1031: UPS 03.1 and prior), SMC Series (SMC Series ID=1005: UPS 14.1 and prior / SMC Series ID=1007: UPS 11.0 and prior / SMC Series ID=1041: UPS 01.1 and prior), SCL Series (SCL Series ID=1030: UPS 02.5 and prior / SCL Series ID=1036: UPS 02.5 and prior), SMX Series (SMX Series ID=20: UPS 10.2 and prior / SMX Series ID=23: UPS 07.0 and prior), SRT Series (SRT Series ID=1010/1019/1025: UPS 08.3 and prior / SRT Series ID=1024: UPS 01.0 and prior / SRT Series ID=1020: UPS 10.4 and prior / SRT Series ID=1021: UPS 12.2 and prior / SRT Series ID=1001/1013: UPS 05.1 and prior / SRT Series ID=1002/1014: UPSa05.2 and prior), APC SmartConnect Family: SMT Series (SMT Series ID=1015: UPS 04.5 and prior), SMC Series (SMC Series ID=1018: UPS 04.2 and prior), SMTL Series (SMTL Series ID=1026: UPS 02.9 and prior), SCL Series (SCL Series ID=1029: UPS 02.5 and prior / SCL Series ID=1030: UPS 02.5 and prior / SCL Series ID=1036: UPS 02.5 and prior / SCL Series ID=1037: UPS 03.1 and prior), SMX Series (SMX Series ID=1031: UPS 03.1 and prior)"
                }
              ]
            },
            "generator": {
              "engine": "Vulnogram 0.0.9"
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-287 Improper Authentication"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.se.com/ww/en/download/document/SEVD-2022-067-02/",
                  "refsource": "MISC",
                  "url": "https://www.se.com/ww/en/download/document/SEVD-2022-067-02/"
                }
              ]
            },
            "source": {
              "discovery": "UNKNOWN"
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
        "assignerShortName": "schneider",
        "cveId": "CVE-2022-0715",
        "datePublished": "2022-03-09T19:30:14.000Z",
        "dateReserved": "2022-02-21T00:00:00.000Z",
        "dateUpdated": "2026-05-29T14:05:59.422Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2022-0715 (GCVE-0-2022-0715)

    Vulnerability from cvelistv5 – Published: 2022-03-09 19:30 – Updated: 2026-05-29 14:05
    VLAI
    Summary
    A CWE-287: Improper Authentication vulnerability exists that could cause an attacker to arbitrarily change the behavior of the UPS when a key is leaked and used to upload malicious firmware. Affected Product: APC Smart-UPS Family: SMT Series (SMT Series ID=18: UPS 09.8 and prior / SMT Series ID=1040: UPS 01.2 and prior / SMT Series ID=1031: UPS 03.1 and prior), SMC Series (SMC Series ID=1005: UPS 14.1 and prior / SMC Series ID=1007: UPS 11.0 and prior / SMC Series ID=1041: UPS 01.1 and prior), SCL Series (SCL Series ID=1030: UPS 02.5 and prior / SCL Series ID=1036: UPS 02.5 and prior), SMX Series (SMX Series ID=20: UPS 10.2 and prior / SMX Series ID=23: UPS 07.0 and prior), SRT Series (SRT Series ID=1010/1019/1025: UPS 08.3 and prior / SRT Series ID=1024: UPS 01.0 and prior / SRT Series ID=1020: UPS 10.4 and prior / SRT Series ID=1021: UPS 12.2 and prior / SRT Series ID=1001/1013: UPS 05.1 and prior / SRT Series ID=1002/1014: UPSa05.2 and prior), APC SmartConnect Family: SMT Series (SMT Series ID=1015: UPS 04.5 and prior), SMC Series (SMC Series ID=1018: UPS 04.2 and prior), SMTL Series (SMTL Series ID=1026: UPS 02.9 and prior), SCL Series (SCL Series ID=1029: UPS 02.5 and prior / SCL Series ID=1030: UPS 02.5 and prior / SCL Series ID=1036: UPS 02.5 and prior / SCL Series ID=1037: UPS 03.1 and prior), SMX Series (SMX Series ID=1031: UPS 03.1 and prior)
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-05-29 14:04 UTC
    CWE
    • CWE-287 - Improper Authentication
    Assigner
    schneider CNA under the mitre root
    CNA scorecard C 65/100 over 20 records in the last 180 days details
    References
    Impacted products
    Vendor Product Version
    Schneider Electric APC Smart-UPS Affected: SMT Series
    Affected: SMC Series
    Affected: SCL Series
    Affected: SMX Series
    Affected: SRT Series
    Create a notification for this product.
    Schneider Electric SmartConnect Affected: SMT Series
    Affected: SMC Series
    Affected: SMTL Series
    Affected: SCL Series
    Affected: SMX Series
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T23:40:03.366Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.se.com/ww/en/download/document/SEVD-2022-067-02/"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "cvssV3_1": {
                  "attackComplexity": "HIGH",
                  "attackVector": "NETWORK",
                  "availabilityImpact": "HIGH",
                  "baseScore": 8.9,
                  "baseSeverity": "HIGH",
                  "confidentialityImpact": "LOW",
                  "integrityImpact": "HIGH",
                  "privilegesRequired": "NONE",
                  "scope": "CHANGED",
                  "userInteraction": "NONE",
                  "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:C/C:L/I:H/A:H",
                  "version": "3.1"
                }
              },
              {
                "other": {
                  "content": {
                    "id": "CVE-2022-0715",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-05-29T14:04:24.695082Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-05-29T14:05:59.422Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "APC Smart-UPS",
              "vendor": "Schneider Electric",
              "versions": [
                {
                  "status": "affected",
                  "version": "SMT Series"
                },
                {
                  "status": "affected",
                  "version": "SMC Series"
                },
                {
                  "status": "affected",
                  "version": "SCL Series"
                },
                {
                  "status": "affected",
                  "version": "SMX Series"
                },
                {
                  "status": "affected",
                  "version": "SRT Series"
                }
              ]
            },
            {
              "product": "SmartConnect",
              "vendor": "Schneider Electric",
              "versions": [
                {
                  "status": "affected",
                  "version": "SMT Series"
                },
                {
                  "status": "affected",
                  "version": "SMC Series"
                },
                {
                  "status": "affected",
                  "version": "SMTL Series"
                },
                {
                  "status": "affected",
                  "version": "SCL Series"
                },
                {
                  "status": "affected",
                  "version": "SMX Series"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A CWE-287: Improper Authentication vulnerability exists that could cause an attacker to arbitrarily change the behavior of the UPS when a key is leaked and used to upload malicious firmware. Affected Product: APC Smart-UPS Family: SMT Series (SMT Series ID=18: UPS 09.8 and prior / SMT Series ID=1040: UPS 01.2 and prior / SMT Series ID=1031: UPS 03.1 and prior), SMC Series (SMC Series ID=1005: UPS 14.1 and prior / SMC Series ID=1007: UPS 11.0 and prior / SMC Series ID=1041: UPS 01.1 and prior), SCL Series (SCL Series ID=1030: UPS 02.5 and prior / SCL Series ID=1036: UPS 02.5 and prior), SMX Series (SMX Series ID=20: UPS 10.2 and prior / SMX Series ID=23: UPS 07.0 and prior), SRT Series (SRT Series ID=1010/1019/1025: UPS 08.3 and prior / SRT Series ID=1024: UPS 01.0 and prior / SRT Series ID=1020: UPS 10.4 and prior / SRT Series ID=1021: UPS 12.2 and prior / SRT Series ID=1001/1013: UPS 05.1 and prior / SRT Series ID=1002/1014: UPSa05.2 and prior), APC SmartConnect Family: SMT Series (SMT Series ID=1015: UPS 04.5 and prior), SMC Series (SMC Series ID=1018: UPS 04.2 and prior), SMTL Series (SMTL Series ID=1026: UPS 02.9 and prior), SCL Series (SCL Series ID=1029: UPS 02.5 and prior / SCL Series ID=1030: UPS 02.5 and prior / SCL Series ID=1036: UPS 02.5 and prior / SCL Series ID=1037: UPS 03.1 and prior), SMX Series (SMX Series ID=1031: UPS 03.1 and prior)"
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-287",
                  "description": "CWE-287 Improper Authentication",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2022-03-28T16:25:27.000Z",
            "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
            "shortName": "schneider"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.se.com/ww/en/download/document/SEVD-2022-067-02/"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "x_generator": {
            "engine": "Vulnogram 0.0.9"
          },
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cybersecurity@schneider-electric.com",
              "ID": "CVE-2022-0715",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "APC Smart-UPS",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "SMT Series"
                              },
                              {
                                "version_value": "SMC Series"
                              },
                              {
                                "version_value": "SCL Series"
                              },
                              {
                                "version_value": "SMX Series"
                              },
                              {
                                "version_value": "SRT Series"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "SmartConnect",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "SMT Series"
                              },
                              {
                                "version_value": "SMC Series"
                              },
                              {
                                "version_value": "SMTL Series"
                              },
                              {
                                "version_value": "SCL Series"
                              },
                              {
                                "version_value": "SMX Series"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "Schneider Electric"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "A CWE-287: Improper Authentication vulnerability exists that could cause an attacker to arbitrarily change the behavior of the UPS when a key is leaked and used to upload malicious firmware. Affected Product: APC Smart-UPS Family: SMT Series (SMT Series ID=18: UPS 09.8 and prior / SMT Series ID=1040: UPS 01.2 and prior / SMT Series ID=1031: UPS 03.1 and prior), SMC Series (SMC Series ID=1005: UPS 14.1 and prior / SMC Series ID=1007: UPS 11.0 and prior / SMC Series ID=1041: UPS 01.1 and prior), SCL Series (SCL Series ID=1030: UPS 02.5 and prior / SCL Series ID=1036: UPS 02.5 and prior), SMX Series (SMX Series ID=20: UPS 10.2 and prior / SMX Series ID=23: UPS 07.0 and prior), SRT Series (SRT Series ID=1010/1019/1025: UPS 08.3 and prior / SRT Series ID=1024: UPS 01.0 and prior / SRT Series ID=1020: UPS 10.4 and prior / SRT Series ID=1021: UPS 12.2 and prior / SRT Series ID=1001/1013: UPS 05.1 and prior / SRT Series ID=1002/1014: UPSa05.2 and prior), APC SmartConnect Family: SMT Series (SMT Series ID=1015: UPS 04.5 and prior), SMC Series (SMC Series ID=1018: UPS 04.2 and prior), SMTL Series (SMTL Series ID=1026: UPS 02.9 and prior), SCL Series (SCL Series ID=1029: UPS 02.5 and prior / SCL Series ID=1030: UPS 02.5 and prior / SCL Series ID=1036: UPS 02.5 and prior / SCL Series ID=1037: UPS 03.1 and prior), SMX Series (SMX Series ID=1031: UPS 03.1 and prior)"
                }
              ]
            },
            "generator": {
              "engine": "Vulnogram 0.0.9"
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-287 Improper Authentication"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.se.com/ww/en/download/document/SEVD-2022-067-02/",
                  "refsource": "MISC",
                  "url": "https://www.se.com/ww/en/download/document/SEVD-2022-067-02/"
                }
              ]
            },
            "source": {
              "discovery": "UNKNOWN"
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
        "assignerShortName": "schneider",
        "cveId": "CVE-2022-0715",
        "datePublished": "2022-03-09T19:30:14.000Z",
        "dateReserved": "2022-02-21T00:00:00.000Z",
        "dateUpdated": "2026-05-29T14:05:59.422Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }