Search

Find a vulnerability

Search criteria

    9 vulnerabilities found for smc_series_1018_ups_firmware by schneider-electric

    FKIE_CVE-2022-22806

    Vulnerability from fkie_nvd - Published: 2022-03-09 20:15 - Updated: 2026-06-17 04:29
    Summary
    A CWE-294: Authentication Bypass by Capture-replay vulnerability exists that could cause an unauthenticated connection to the UPS when a malformed connection is sent. Affected Product: SmartConnect Family: SMT Series (SMT Series ID=1015: UPS 04.5 and prior), SMC Series (SMC Series ID=1018: UPS 04.2 and prior), SMTL Series (SMTL Series ID=1026: UPS 02.9 and prior), SCL Series (SCL Series ID=1029: UPS 02.5 and prior / SCL Series ID=1030: UPS 02.5 and prior / SCL Series ID=1036: UPS 02.5 and prior / SCL Series ID=1037: UPS 03.1 and prior), SMX Series (SMX Series ID=1031: UPS 03.1 and prior)

    {
      "affected": [
        {
          "affectedData": [
            {
              "product": "SmartConnect",
              "vendor": "Schneider Electric",
              "versions": [
                {
                  "status": "affected",
                  "version": "SMT Series"
                },
                {
                  "status": "affected",
                  "version": "SMC Series"
                },
                {
                  "status": "affected",
                  "version": "SMTL Series"
                },
                {
                  "status": "affected",
                  "version": "SCL Series"
                },
                {
                  "status": "affected",
                  "version": "SMX Series"
                }
              ]
            }
          ],
          "source": "cybersecurity@se.com"
        }
      ],
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:schneider-electric:smt_series_1015_ups_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "2C3EA55B-DB09-4124-A9D9-A92431C38D1F",
                  "versionEndIncluding": "04.5",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:schneider-electric:smt_series_1015_ups:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "95C1E3D9-606B-4C57-A4E7-0A45C9D46332",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:schneider-electric:smc_series_1018_ups_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "FFE2D844-ED18-44D3-9E75-4BB3082E4B51",
                  "versionEndIncluding": "04.2",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:schneider-electric:smc_series_1018_ups:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "154E788E-173C-4D16-A492-B61D39D420EF",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:schneider-electric:smtl_series_1026_ups_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "AE693F05-B0A7-452D-94C6-D36E37ACF6CB",
                  "versionEndIncluding": "02.9",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:schneider-electric:smtl_series_1026_ups:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "6B138EB4-6264-4BFA-B4C7-4B23FFA676B1",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:schneider-electric:scl_series_1029_ups_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "C2E0803A-637E-4BBA-B9D5-AB59EE122844",
                  "versionEndIncluding": "02.5",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:schneider-electric:scl_series_1029_ups:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "4175BEC7-DA4D-4E19-A642-A5FC13D3598E",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:schneider-electric:scl_series_1030_ups_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "469F9813-DE0E-4752-91EB-FECC001C6825",
                  "versionEndIncluding": "02.5",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:schneider-electric:scl_series_1030_ups:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "E8DC43CB-66C0-469B-AF87-0120D6280584",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:schneider-electric:scl_series_1036_ups_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "22E4C951-876D-46F7-8CF4-D943464E8338",
                  "versionEndIncluding": "02.5",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:schneider-electric:scl_series_1036_ups:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "9FB7E0EB-AF6D-4107-B343-50309E9DF03E",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:schneider-electric:scl_series_1037_ups_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "3E52A522-88D4-4B6A-83B4-C56C093C7F54",
                  "versionEndIncluding": "03.1",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:schneider-electric:scl_series_1037_ups:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "04C627CE-E3F8-4E3F-8B93-07C92AA21296",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:schneider-electric:smx_series_1031_ups_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "6251AE4E-FFED-4B0C-A90B-A3BD852A2ED8",
                  "versionEndIncluding": "03.1",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:schneider-electric:smx_series_1031_ups:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "9E1E7040-8123-483C-AE62-F190D83D0ADC",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        }
      ],
      "cveTags": [],
      "descriptions": [
        {
          "lang": "en",
          "value": "A CWE-294: Authentication Bypass by Capture-replay vulnerability exists that could cause an unauthenticated connection to the UPS when a malformed connection is sent. Affected Product: SmartConnect Family: SMT Series (SMT Series ID=1015: UPS 04.5 and prior), SMC Series (SMC Series ID=1018: UPS 04.2 and prior), SMTL Series (SMTL Series ID=1026: UPS 02.9 and prior), SCL Series (SCL Series ID=1029: UPS 02.5 and prior / SCL Series ID=1030: UPS 02.5 and prior / SCL Series ID=1036: UPS 02.5 and prior / SCL Series ID=1037: UPS 03.1 and prior), SMX Series (SMX Series ID=1031: UPS 03.1 and prior)"
        },
        {
          "lang": "es",
          "value": "Una CWE-294: se presenta una vulnerabilidad de Omisi\u00f3n de la Autenticaci\u00f3n Mediante Captura-repetici\u00f3n que podr\u00eda causar una conexi\u00f3n no autenticada al SAI cuando se env\u00eda una conexi\u00f3n malformada. Producto afectado: Familia SmartConnect: Serie SMT (SMT Series ID=1015: UPS 04.5 y anteriores), Serie SMC (SMC Series ID=1018: UPS 04.2 y anteriores), Serie SMTL (SMTL Series ID=1026: UPS 02.9 y anteriores), Serie SCL (SCL Series ID=1029: UPS 02. 5 y anteriores / SCL Series ID=1030: UPS 02.5 y anteriores / SCL Series ID=1036: UPS 02.5 y anteriores / SCL Series ID=1037: UPS 03.1 y anteriores), SMX Series (SMX Series ID=1031: UPS 03.1 y anteriores)"
        }
      ],
      "id": "CVE-2022-22806",
      "lastModified": "2026-06-17T04:29:04.243",
      "metrics": {
        "cvssMetricV2": [
          {
            "acInsufInfo": false,
            "baseSeverity": "HIGH",
            "cvssData": {
              "accessComplexity": "LOW",
              "accessVector": "NETWORK",
              "authentication": "NONE",
              "availabilityImpact": "PARTIAL",
              "baseScore": 7.5,
              "confidentialityImpact": "PARTIAL",
              "integrityImpact": "PARTIAL",
              "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
              "version": "2.0"
            },
            "exploitabilityScore": 10.0,
            "impactScore": 6.4,
            "obtainAllPrivilege": false,
            "obtainOtherPrivilege": false,
            "obtainUserPrivilege": false,
            "source": "nvd@nist.gov",
            "type": "Primary",
            "userInteractionRequired": false
          }
        ],
        "cvssMetricV31": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 9.8,
              "baseSeverity": "CRITICAL",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
              "version": "3.1"
            },
            "exploitabilityScore": 3.9,
            "impactScore": 5.9,
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ]
      },
      "published": "2022-03-09T20:15:08.510",
      "references": [
        {
          "source": "cybersecurity@se.com",
          "tags": [
            "Vendor Advisory"
          ],
          "url": "https://www.se.com/ww/en/download/document/SEVD-2022-067-02/"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Vendor Advisory"
          ],
          "url": "https://www.se.com/ww/en/download/document/SEVD-2022-067-02/"
        }
      ],
      "sourceIdentifier": "cybersecurity@se.com",
      "vulnStatus": "Modified",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-294"
            }
          ],
          "source": "cybersecurity@se.com",
          "type": "Secondary"
        },
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-294"
            }
          ],
          "source": "nvd@nist.gov",
          "type": "Secondary"
        }
      ]
    }

    FKIE_CVE-2022-22805

    Vulnerability from fkie_nvd - Published: 2022-03-09 20:15 - Updated: 2026-06-17 04:29
    Summary
    A CWE-120: Buffer Copy without Checking Size of Input ('Classic Buffer Overflow') vulnerability exists that could cause remote code execution when an improperly handled TLS packet is reassembled. Affected Product: SmartConnect Family: SMT Series (SMT Series ID=1015: UPS 04.5 and prior), SMC Series (SMC Series ID=1018: UPS 04.2 and prior), SMTL Series (SMTL Series ID=1026: UPS 02.9 and prior), SCL Series (SCL Series ID=1029: UPS 02.5 and prior / SCL Series ID=1030: UPS 02.5 and prior / SCL Series ID=1036: UPS 02.5 and prior / SCL Series ID=1037: UPS 03.1 and prior), SMX Series (SMX Series ID=1031: UPS 03.1 and prior)

    {
      "affected": [
        {
          "affectedData": [
            {
              "product": "SmartConnect",
              "vendor": "Schneider Electric",
              "versions": [
                {
                  "status": "affected",
                  "version": "SMT Series"
                },
                {
                  "status": "affected",
                  "version": "SMC Series"
                },
                {
                  "status": "affected",
                  "version": "SMTL Series"
                },
                {
                  "status": "affected",
                  "version": "SCL Series"
                },
                {
                  "status": "affected",
                  "version": "SMX Series"
                }
              ]
            }
          ],
          "source": "cybersecurity@se.com"
        }
      ],
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:schneider-electric:smt_series_1015_ups_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "2C3EA55B-DB09-4124-A9D9-A92431C38D1F",
                  "versionEndIncluding": "04.5",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:schneider-electric:smt_series_1015_ups:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "95C1E3D9-606B-4C57-A4E7-0A45C9D46332",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:schneider-electric:smc_series_1018_ups_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "FFE2D844-ED18-44D3-9E75-4BB3082E4B51",
                  "versionEndIncluding": "04.2",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:schneider-electric:smc_series_1018_ups:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "154E788E-173C-4D16-A492-B61D39D420EF",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:schneider-electric:smtl_series_1026_ups_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "AE693F05-B0A7-452D-94C6-D36E37ACF6CB",
                  "versionEndIncluding": "02.9",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:schneider-electric:smtl_series_1026_ups:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "6B138EB4-6264-4BFA-B4C7-4B23FFA676B1",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:schneider-electric:scl_series_1029_ups_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "C2E0803A-637E-4BBA-B9D5-AB59EE122844",
                  "versionEndIncluding": "02.5",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:schneider-electric:scl_series_1029_ups:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "4175BEC7-DA4D-4E19-A642-A5FC13D3598E",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:schneider-electric:scl_series_1030_ups_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "469F9813-DE0E-4752-91EB-FECC001C6825",
                  "versionEndIncluding": "02.5",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:schneider-electric:scl_series_1030_ups:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "E8DC43CB-66C0-469B-AF87-0120D6280584",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:schneider-electric:scl_series_1036_ups_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "22E4C951-876D-46F7-8CF4-D943464E8338",
                  "versionEndIncluding": "02.5",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:schneider-electric:scl_series_1036_ups:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "9FB7E0EB-AF6D-4107-B343-50309E9DF03E",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:schneider-electric:scl_series_1037_ups_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "3E52A522-88D4-4B6A-83B4-C56C093C7F54",
                  "versionEndIncluding": "03.1",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:schneider-electric:scl_series_1037_ups:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "04C627CE-E3F8-4E3F-8B93-07C92AA21296",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:schneider-electric:smx_series_1031_ups_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "6251AE4E-FFED-4B0C-A90B-A3BD852A2ED8",
                  "versionEndIncluding": "03.1",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:schneider-electric:smx_series_1031_ups:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "9E1E7040-8123-483C-AE62-F190D83D0ADC",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        }
      ],
      "cveTags": [],
      "descriptions": [
        {
          "lang": "en",
          "value": "A CWE-120: Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027) vulnerability exists that could cause remote code execution when an improperly handled TLS packet is reassembled. Affected Product: SmartConnect Family: SMT Series (SMT Series ID=1015: UPS 04.5 and prior), SMC Series (SMC Series ID=1018: UPS 04.2 and prior), SMTL Series (SMTL Series ID=1026: UPS 02.9 and prior), SCL Series (SCL Series ID=1029: UPS 02.5 and prior / SCL Series ID=1030: UPS 02.5 and prior / SCL Series ID=1036: UPS 02.5 and prior / SCL Series ID=1037: UPS 03.1 and prior), SMX Series (SMX Series ID=1031: UPS 03.1 and prior)"
        },
        {
          "lang": "es",
          "value": "Existe una vulnerabilidad CWE-120: Copia del b\u00fafer sin comprobar el tama\u00f1o de la entrada (\u0027Desbordamiento cl\u00e1sico del b\u00fafer\u0027) que podr\u00eda causar la ejecuci\u00f3n remota de c\u00f3digo cuando se reensambla un paquete TLS mal gestionado. Producto afectado: Familia SmartConnect: Serie SMT (SMT Series ID=1015: UPS 04.5 y anteriores), Serie SMC (SMC Series ID=1018: UPS 04.2 y anteriores), Serie SMTL (SMTL Series ID=1026: UPS 02.9 y anteriores), Serie SCL (SCL Series ID=1029: UPS 02. 5 y anteriores / SCL Series ID=1030: UPS 02.5 y anteriores / SCL Series ID=1036: UPS 02.5 y anteriores / SCL Series ID=1037: UPS 03.1 y anteriores), SMX Series (SMX Series ID=1031: UPS 03.1 y anteriores)"
        }
      ],
      "id": "CVE-2022-22805",
      "lastModified": "2026-06-17T04:29:04.137",
      "metrics": {
        "cvssMetricV2": [
          {
            "acInsufInfo": false,
            "baseSeverity": "HIGH",
            "cvssData": {
              "accessComplexity": "LOW",
              "accessVector": "NETWORK",
              "authentication": "NONE",
              "availabilityImpact": "PARTIAL",
              "baseScore": 7.5,
              "confidentialityImpact": "PARTIAL",
              "integrityImpact": "PARTIAL",
              "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
              "version": "2.0"
            },
            "exploitabilityScore": 10.0,
            "impactScore": 6.4,
            "obtainAllPrivilege": false,
            "obtainOtherPrivilege": false,
            "obtainUserPrivilege": false,
            "source": "nvd@nist.gov",
            "type": "Primary",
            "userInteractionRequired": false
          }
        ],
        "cvssMetricV31": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 9.8,
              "baseSeverity": "CRITICAL",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
              "version": "3.1"
            },
            "exploitabilityScore": 3.9,
            "impactScore": 5.9,
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ]
      },
      "published": "2022-03-09T20:15:08.460",
      "references": [
        {
          "source": "cybersecurity@se.com",
          "tags": [
            "Vendor Advisory"
          ],
          "url": "https://www.se.com/ww/en/download/document/SEVD-2022-067-02/"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Vendor Advisory"
          ],
          "url": "https://www.se.com/ww/en/download/document/SEVD-2022-067-02/"
        }
      ],
      "sourceIdentifier": "cybersecurity@se.com",
      "vulnStatus": "Modified",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-120"
            }
          ],
          "source": "cybersecurity@se.com",
          "type": "Secondary"
        },
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-120"
            }
          ],
          "source": "nvd@nist.gov",
          "type": "Secondary"
        }
      ]
    }

    FKIE_CVE-2022-0715

    Vulnerability from fkie_nvd - Published: 2022-03-09 20:15 - Updated: 2026-06-17 04:21
    Summary
    A CWE-287: Improper Authentication vulnerability exists that could cause an attacker to arbitrarily change the behavior of the UPS when a key is leaked and used to upload malicious firmware. Affected Product: APC Smart-UPS Family: SMT Series (SMT Series ID=18: UPS 09.8 and prior / SMT Series ID=1040: UPS 01.2 and prior / SMT Series ID=1031: UPS 03.1 and prior), SMC Series (SMC Series ID=1005: UPS 14.1 and prior / SMC Series ID=1007: UPS 11.0 and prior / SMC Series ID=1041: UPS 01.1 and prior), SCL Series (SCL Series ID=1030: UPS 02.5 and prior / SCL Series ID=1036: UPS 02.5 and prior), SMX Series (SMX Series ID=20: UPS 10.2 and prior / SMX Series ID=23: UPS 07.0 and prior), SRT Series (SRT Series ID=1010/1019/1025: UPS 08.3 and prior / SRT Series ID=1024: UPS 01.0 and prior / SRT Series ID=1020: UPS 10.4 and prior / SRT Series ID=1021: UPS 12.2 and prior / SRT Series ID=1001/1013: UPS 05.1 and prior / SRT Series ID=1002/1014: UPSa05.2 and prior), APC SmartConnect Family: SMT Series (SMT Series ID=1015: UPS 04.5 and prior), SMC Series (SMC Series ID=1018: UPS 04.2 and prior), SMTL Series (SMTL Series ID=1026: UPS 02.9 and prior), SCL Series (SCL Series ID=1029: UPS 02.5 and prior / SCL Series ID=1030: UPS 02.5 and prior / SCL Series ID=1036: UPS 02.5 and prior / SCL Series ID=1037: UPS 03.1 and prior), SMX Series (SMX Series ID=1031: UPS 03.1 and prior)
    Impacted products
    Vendor Product Version
    schneider-electric smt_series_1015_ups_firmware *
    schneider-electric smt_series_1015_ups -
    schneider-electric smc_series_1018_ups_firmware *
    schneider-electric smc_series_1018_ups -
    schneider-electric smtl_series_1026_ups_firmware *
    schneider-electric smtl_series_1026_ups -
    schneider-electric scl_series_1029_ups_firmware *
    schneider-electric scl_series_1029_ups -
    schneider-electric scl_series_1030_ups_firmware *
    schneider-electric scl_series_1030_ups -
    schneider-electric scl_series_1036_ups_firmware *
    schneider-electric scl_series_1036_ups -
    schneider-electric scl_series_1037_ups_firmware *
    schneider-electric scl_series_1037_ups -
    schneider-electric smx_series_1031_ups_firmware *
    schneider-electric smx_series_1031_ups -
    schneider-electric smt_series_18_ups_firmware *
    schneider-electric smt_series_18_ups -
    schneider-electric smt_series_1040_ups_firmware *
    schneider-electric smt_series_1040_ups -
    schneider-electric smt_series_1031_ups_firmware *
    schneider-electric smt_series_1031_ups -
    schneider-electric smc_series_1005_ups_firmware *
    schneider-electric smc_series_1005_ups -
    schneider-electric smc_series_1007_ups_firmware *
    schneider-electric smc_series_1007_ups -
    schneider-electric smc_series_1041_ups_firmware *
    schneider-electric smc_series_1041_ups -
    schneider-electric scl_series_1030_ups_firmware *
    schneider-electric scl_series_1030_ups -
    schneider-electric scl_series_1036_ups_firmware *
    schneider-electric scl_series_1036_ups -
    schneider-electric smx_series_20_ups_firmware *
    schneider-electric smx_series_20_ups -
    schneider-electric smx_series_23_ups_firmware *
    schneider-electric smx_series_23_ups -
    schneider-electric srt_series_1010_ups_firmware *
    schneider-electric srt_series_1010_ups -
    schneider-electric srt_series_1019_ups_firmware *
    schneider-electric srt_series_1019_ups -
    schneider-electric srt_series_1025_ups_firmware *
    schneider-electric srt_series_1025_ups -
    schneider-electric srt_series_1020_ups_firmware *
    schneider-electric srt_series_1020_ups -
    schneider-electric srt_series_1021_ups_firmware *
    schneider-electric srt_series_1021_ups -
    schneider-electric srt_series_1001_ups_firmware *
    schneider-electric srt_series_1001_ups -
    schneider-electric srt_series_1013_ups_firmware *
    schneider-electric srt_series_1013_ups -
    schneider-electric srt_series_1002_ups_firmware *
    schneider-electric srt_series_1002_ups -
    schneider-electric srt_series_1014_ups_firmware *
    schneider-electric srt_series_1014_ups -
    schneider-electric srtl1000rmxli_firmware *
    schneider-electric srtl1000rmxli -
    schneider-electric srtl1000rmxli-nc_firmware *
    schneider-electric srtl1000rmxli-nc -
    schneider-electric srtl1500rmxli-nc_firmware *
    schneider-electric srtl1500rmxli-nc -
    schneider-electric srtl1500rmxli_firmware *
    schneider-electric srtl1500rmxli -
    schneider-electric srtl2200rmxli_firmware *
    schneider-electric srtl2200rmxli -
    schneider-electric srtl2200rmxli-nc_firmware *
    schneider-electric srtl2200rmxli-nc -
    schneider-electric srtl3000rmxli-nc_firmware *
    schneider-electric srtl3000rmxli-nc -
    schneider-electric srtl3000rmxli_firmware *
    schneider-electric srtl3000rmxli -

    {
      "affected": [
        {
          "affectedData": [
            {
              "product": "APC Smart-UPS",
              "vendor": "Schneider Electric",
              "versions": [
                {
                  "status": "affected",
                  "version": "SMT Series"
                },
                {
                  "status": "affected",
                  "version": "SMC Series"
                },
                {
                  "status": "affected",
                  "version": "SCL Series"
                },
                {
                  "status": "affected",
                  "version": "SMX Series"
                },
                {
                  "status": "affected",
                  "version": "SRT Series"
                }
              ]
            },
            {
              "product": "SmartConnect",
              "vendor": "Schneider Electric",
              "versions": [
                {
                  "status": "affected",
                  "version": "SMT Series"
                },
                {
                  "status": "affected",
                  "version": "SMC Series"
                },
                {
                  "status": "affected",
                  "version": "SMTL Series"
                },
                {
                  "status": "affected",
                  "version": "SCL Series"
                },
                {
                  "status": "affected",
                  "version": "SMX Series"
                }
              ]
            }
          ],
          "source": "cybersecurity@se.com"
        }
      ],
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:schneider-electric:smt_series_1015_ups_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "2C3EA55B-DB09-4124-A9D9-A92431C38D1F",
                  "versionEndIncluding": "04.5",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:schneider-electric:smt_series_1015_ups:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "95C1E3D9-606B-4C57-A4E7-0A45C9D46332",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:schneider-electric:smc_series_1018_ups_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "FFE2D844-ED18-44D3-9E75-4BB3082E4B51",
                  "versionEndIncluding": "04.2",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:schneider-electric:smc_series_1018_ups:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "154E788E-173C-4D16-A492-B61D39D420EF",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:schneider-electric:smtl_series_1026_ups_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "AE693F05-B0A7-452D-94C6-D36E37ACF6CB",
                  "versionEndIncluding": "02.9",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:schneider-electric:smtl_series_1026_ups:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "6B138EB4-6264-4BFA-B4C7-4B23FFA676B1",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:schneider-electric:scl_series_1029_ups_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "C2E0803A-637E-4BBA-B9D5-AB59EE122844",
                  "versionEndIncluding": "02.5",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:schneider-electric:scl_series_1029_ups:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "4175BEC7-DA4D-4E19-A642-A5FC13D3598E",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:schneider-electric:scl_series_1030_ups_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "469F9813-DE0E-4752-91EB-FECC001C6825",
                  "versionEndIncluding": "02.5",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:schneider-electric:scl_series_1030_ups:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "E8DC43CB-66C0-469B-AF87-0120D6280584",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:schneider-electric:scl_series_1036_ups_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "22E4C951-876D-46F7-8CF4-D943464E8338",
                  "versionEndIncluding": "02.5",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:schneider-electric:scl_series_1036_ups:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "9FB7E0EB-AF6D-4107-B343-50309E9DF03E",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:schneider-electric:scl_series_1037_ups_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "3E52A522-88D4-4B6A-83B4-C56C093C7F54",
                  "versionEndIncluding": "03.1",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:schneider-electric:scl_series_1037_ups:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "04C627CE-E3F8-4E3F-8B93-07C92AA21296",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:schneider-electric:smx_series_1031_ups_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "6251AE4E-FFED-4B0C-A90B-A3BD852A2ED8",
                  "versionEndIncluding": "03.1",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:schneider-electric:smx_series_1031_ups:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "9E1E7040-8123-483C-AE62-F190D83D0ADC",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:schneider-electric:smt_series_18_ups_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "A9B1431D-822C-47DF-8643-7D5E778A43AD",
                  "versionEndIncluding": "09.8",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:schneider-electric:smt_series_18_ups:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "0E1F03F0-11F1-437A-8FD8-A3C8186D02DE",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:schneider-electric:smt_series_1040_ups_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "660A5F99-3370-48C9-A3C8-A54FFAC9BEE6",
                  "versionEndIncluding": "01.2",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:schneider-electric:smt_series_1040_ups:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "848020CF-D33A-4196-BB0C-ECD1D43372D7",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:schneider-electric:smt_series_1031_ups_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "CE801653-57F9-4C13-8D23-91D5F22FD2C9",
                  "versionEndIncluding": "03.1",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:schneider-electric:smt_series_1031_ups:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "E1467655-7784-4287-8C32-3F522A49411D",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:schneider-electric:smc_series_1005_ups_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "1B5D15FE-D25F-4827-99C2-2B15DA5726F3",
                  "versionEndIncluding": "14.1",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:schneider-electric:smc_series_1005_ups:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "26B5EC8E-4FF9-4ED0-AB70-B5F6DBA72632",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:schneider-electric:smc_series_1007_ups_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "4929654C-D91D-4228-807B-F9DAC9D8C931",
                  "versionEndIncluding": "11.0",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:schneider-electric:smc_series_1007_ups:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "2761A47B-326E-4CD0-96D6-12796992769D",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:schneider-electric:smc_series_1041_ups_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "428CBB13-0227-4557-8A22-DE8165949D3B",
                  "versionEndIncluding": "01.1",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:schneider-electric:smc_series_1041_ups:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "7FEFAD29-12AD-454B-BAFC-4C17A1D1E8E1",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:schneider-electric:scl_series_1030_ups_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "469F9813-DE0E-4752-91EB-FECC001C6825",
                  "versionEndIncluding": "02.5",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:schneider-electric:scl_series_1030_ups:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "E8DC43CB-66C0-469B-AF87-0120D6280584",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:schneider-electric:scl_series_1036_ups_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "22E4C951-876D-46F7-8CF4-D943464E8338",
                  "versionEndIncluding": "02.5",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:schneider-electric:scl_series_1036_ups:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "9FB7E0EB-AF6D-4107-B343-50309E9DF03E",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:schneider-electric:smx_series_20_ups_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "49A9A0AA-9E54-426D-B3DF-A896119DCFCB",
                  "versionEndIncluding": "10.2",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:schneider-electric:smx_series_20_ups:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "9869EFE8-DED1-40D9-8BD6-003E0507995F",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:schneider-electric:smx_series_23_ups_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "AD04C6BF-A05F-41DC-9DB8-6ECBEF570FA3",
                  "versionEndIncluding": "07.0",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:schneider-electric:smx_series_23_ups:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "A58B76AA-7DFC-4F6C-B6E6-4B19746788B3",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:schneider-electric:srt_series_1010_ups_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "6717F4F6-F033-48CB-A4BA-6E19DAD98FE5",
                  "versionEndIncluding": "08.3",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:schneider-electric:srt_series_1010_ups:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "83769E66-3290-4559-AD5A-C65BE83B27A1",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:schneider-electric:srt_series_1019_ups_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "A45A70DF-4794-4E45-B134-EB8435AC5FB8",
                  "versionEndIncluding": "08.3",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:schneider-electric:srt_series_1019_ups:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "09A53A75-F08A-47E9-A3CF-691EE7B475B7",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:schneider-electric:srt_series_1025_ups_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "B73BB6AE-8CC4-465F-9C48-B125D0C25F59",
                  "versionEndIncluding": "08.3",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:schneider-electric:srt_series_1025_ups:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "D883C4EF-0530-4E8B-8C83-57B452219687",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:schneider-electric:srt_series_1020_ups_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "CC69A97E-D632-42FE-A217-572EB966085A",
                  "versionEndIncluding": "10.4",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:schneider-electric:srt_series_1020_ups:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "94F049E9-F1D2-4006-9C9A-5DA9C7229087",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:schneider-electric:srt_series_1021_ups_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "CF0C5ED3-2100-48C1-AC5A-E6285487815D",
                  "versionEndIncluding": "12.2",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:schneider-electric:srt_series_1021_ups:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "DEC3AD24-6B13-4A44-A58C-9189BCF480D4",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:schneider-electric:srt_series_1001_ups_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "1D4D6B50-3B1A-47EF-9055-2887128F0224",
                  "versionEndIncluding": "05.1",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:schneider-electric:srt_series_1001_ups:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "EB599BB4-82F4-4E97-BEF5-0ECC587F0A68",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:schneider-electric:srt_series_1013_ups_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "B4B35543-73E5-4EDD-9018-3BE90A5B99C5",
                  "versionEndIncluding": "05.1",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:schneider-electric:srt_series_1013_ups:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "833DCA70-FCBA-4C58-80EE-DEFFD0F661EF",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:schneider-electric:srt_series_1002_ups_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "318BBEA4-EAF2-499A-8E89-39EC58781BA6",
                  "versionEndIncluding": "a05.2",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:schneider-electric:srt_series_1002_ups:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "20C49E94-8D0A-4202-A433-6787BF8E4B68",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:schneider-electric:srt_series_1014_ups_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "043062A8-6D85-46CD-934F-82BF075B8D53",
                  "versionEndIncluding": "a05.2",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:schneider-electric:srt_series_1014_ups:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "B55E3932-EBCF-44CA-930D-F254EFF5FC68",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:schneider-electric:srtl1000rmxli_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "4A9B5DEA-467F-4C36-854A-F7A5967F0BD1",
                  "versionEndIncluding": "01.0",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:schneider-electric:srtl1000rmxli:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "5165586B-64EF-4E2C-B496-2E82A61113A4",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:schneider-electric:srtl1000rmxli-nc_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "FD635E09-A358-422A-9BD0-2B177D98E3EE",
                  "versionEndIncluding": "01.0",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:schneider-electric:srtl1000rmxli-nc:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "13699C09-1AB8-4C43-9621-295413A974FF",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:schneider-electric:srtl1500rmxli-nc_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "1A5732D4-6BBD-41CA-8D24-84F2FC1412AC",
                  "versionEndIncluding": "01.0",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:schneider-electric:srtl1500rmxli-nc:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "773C3D26-4C71-440E-8CCA-85478C59B247",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:schneider-electric:srtl1500rmxli_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "ECDE919A-70ED-411B-9AAA-12C8B9EB1785",
                  "versionEndIncluding": "01.0",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:schneider-electric:srtl1500rmxli:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "C418AEA1-3C77-4969-9651-9995F7DE99EA",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:schneider-electric:srtl2200rmxli_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "40D232F8-B3F7-4CCF-9E08-6EA63AD7596C",
                  "versionEndIncluding": "01.0",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:schneider-electric:srtl2200rmxli:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "7883EDB6-5A6D-4CDF-A467-A46E522B3B22",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:schneider-electric:srtl2200rmxli-nc_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "EB73EFDD-0994-4553-9075-5EB390816B31",
                  "versionEndIncluding": "01.0",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:schneider-electric:srtl2200rmxli-nc:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "54F5A2E5-DA9A-412E-A5FF-9EA97A8A2D9F",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:schneider-electric:srtl3000rmxli-nc_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "66BFDC2B-B658-4782-AB42-14978BFD2ECC",
                  "versionEndIncluding": "01.0",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:schneider-electric:srtl3000rmxli-nc:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "5FE692C1-4995-430A-896E-BDD68325BD16",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:schneider-electric:srtl3000rmxli_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "83E06F71-7148-4B01-913C-5D92AA36C499",
                  "versionEndIncluding": "01.0",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:schneider-electric:srtl3000rmxli:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "42A83199-87D4-4DD2-854F-2EDBD09509C4",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        }
      ],
      "cveTags": [],
      "descriptions": [
        {
          "lang": "en",
          "value": "A CWE-287: Improper Authentication vulnerability exists that could cause an attacker to arbitrarily change the behavior of the UPS when a key is leaked and used to upload malicious firmware. Affected Product: APC Smart-UPS Family: SMT Series (SMT Series ID=18: UPS 09.8 and prior / SMT Series ID=1040: UPS 01.2 and prior / SMT Series ID=1031: UPS 03.1 and prior), SMC Series (SMC Series ID=1005: UPS 14.1 and prior / SMC Series ID=1007: UPS 11.0 and prior / SMC Series ID=1041: UPS 01.1 and prior), SCL Series (SCL Series ID=1030: UPS 02.5 and prior / SCL Series ID=1036: UPS 02.5 and prior), SMX Series (SMX Series ID=20: UPS 10.2 and prior / SMX Series ID=23: UPS 07.0 and prior), SRT Series (SRT Series ID=1010/1019/1025: UPS 08.3 and prior / SRT Series ID=1024: UPS 01.0 and prior / SRT Series ID=1020: UPS 10.4 and prior / SRT Series ID=1021: UPS 12.2 and prior / SRT Series ID=1001/1013: UPS 05.1 and prior / SRT Series ID=1002/1014: UPSa05.2 and prior), APC SmartConnect Family: SMT Series (SMT Series ID=1015: UPS 04.5 and prior), SMC Series (SMC Series ID=1018: UPS 04.2 and prior), SMTL Series (SMTL Series ID=1026: UPS 02.9 and prior), SCL Series (SCL Series ID=1029: UPS 02.5 and prior / SCL Series ID=1030: UPS 02.5 and prior / SCL Series ID=1036: UPS 02.5 and prior / SCL Series ID=1037: UPS 03.1 and prior), SMX Series (SMX Series ID=1031: UPS 03.1 and prior)"
        },
        {
          "lang": "es",
          "value": "Una CWE-287: Se presenta una vulnerabilidad de autenticaci\u00f3n inapropiada que podr\u00eda causar que un atacante cambie arbitrariamente el comportamiento del SAI cuando es filtrada una clave y es usada para cargar firmware malicioso. Producto afectado: Familia de Smart-UPS de APC: Serie SMT (SMT Series ID=18: UPS versiones 09.8 y anteriores / SMT Series ID=1040: UPS versiones 01.2 y anteriores / SMT Series ID=1031: UPS versiones 03.1 y anteriores), SMC Series (SMC Series ID=1005: UPS versiones 14.1 y anteriores / SMC Series ID=1007: UPS versiones 11.0 y anteriores / SMC Series ID=1041: UPS versiones 01.1 y anteriores), SCL Series (SCL Series ID=1030: UPS versiones 02.5 y anteriores / SCL Series ID=1036: UPS versiones 02.5 y anteriores), SMX Series (SMX Series ID=20: UPS versiones 10.2 y anteriores / SMX Series ID=23: UPS versiones 07.0 y anteriores), SRT Series (SRT Series ID=1010/1019/1025: UPS versiones 08.3 y anteriores / SRT Series ID=1024: UPS versiones 01.0 y anteriores / SRT Series ID=1020: UPS versiones 10.4 y anteriores / SRT Series ID=1021: UPS versiones 12.2 y anteriores / SRT Series ID=1001/1013: UPS versiones 05.1 y anteriores / SRT Series ID=1002/1014: UPS versiones a05.2 y anteriores), Familia SmartConnect de APC: Serie SMT (Serie SMT ID=1015: UPS versiones 04.5 y anteriores), Serie SMC (Serie SMC ID=1018: UPS versiones 04.2 y anteriores), Serie SMTL (Serie SMTL ID=1026: UPS versiones 02.9 y anteriores), Serie SCL (Serie SCL ID=1029: UPS versiones 02.5 y anteriores / SCL Series ID=1030: UPS versiones 02.5 y anteriores / SCL Series ID=1036: UPS versiones 02.5 y anteriores / SCL Series ID=1037: UPS versiones 03.1 y anteriores), SMX Series (SMX Series ID=1031: UPS versiones 03.1 y anteriores)"
        }
      ],
      "id": "CVE-2022-0715",
      "lastModified": "2026-06-17T04:21:07.040",
      "metrics": {
        "cvssMetricV2": [
          {
            "acInsufInfo": false,
            "baseSeverity": "MEDIUM",
            "cvssData": {
              "accessComplexity": "LOW",
              "accessVector": "NETWORK",
              "authentication": "NONE",
              "availabilityImpact": "PARTIAL",
              "baseScore": 6.4,
              "confidentialityImpact": "NONE",
              "integrityImpact": "PARTIAL",
              "vectorString": "AV:N/AC:L/Au:N/C:N/I:P/A:P",
              "version": "2.0"
            },
            "exploitabilityScore": 10.0,
            "impactScore": 4.9,
            "obtainAllPrivilege": false,
            "obtainOtherPrivilege": false,
            "obtainUserPrivilege": false,
            "source": "nvd@nist.gov",
            "type": "Primary",
            "userInteractionRequired": false
          }
        ],
        "cvssMetricV31": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 9.1,
              "baseSeverity": "CRITICAL",
              "confidentialityImpact": "NONE",
              "integrityImpact": "HIGH",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:H",
              "version": "3.1"
            },
            "exploitabilityScore": 3.9,
            "impactScore": 5.2,
            "source": "nvd@nist.gov",
            "type": "Primary"
          },
          {
            "cvssData": {
              "attackComplexity": "HIGH",
              "attackVector": "NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 8.9,
              "baseSeverity": "HIGH",
              "confidentialityImpact": "LOW",
              "integrityImpact": "HIGH",
              "privilegesRequired": "NONE",
              "scope": "CHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:C/C:L/I:H/A:H",
              "version": "3.1"
            },
            "exploitabilityScore": 2.2,
            "impactScore": 6.0,
            "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
            "type": "Secondary"
          }
        ],
        "ssvcV203": [
          {
            "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
            "ssvcData": {
              "id": "CVE-2022-0715",
              "options": [
                {
                  "exploitation": "none"
                },
                {
                  "automatable": "no"
                },
                {
                  "technicalImpact": "partial"
                }
              ],
              "role": "CISA Coordinator",
              "timestamp": "2026-05-29T14:04:24.695082Z",
              "version": "2.0.3"
            }
          }
        ]
      },
      "published": "2022-03-09T20:15:08.300",
      "references": [
        {
          "source": "cybersecurity@se.com",
          "tags": [
            "Vendor Advisory"
          ],
          "url": "https://www.se.com/ww/en/download/document/SEVD-2022-067-02/"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Vendor Advisory"
          ],
          "url": "https://www.se.com/ww/en/download/document/SEVD-2022-067-02/"
        }
      ],
      "sourceIdentifier": "cybersecurity@se.com",
      "vulnStatus": "Modified",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-287"
            }
          ],
          "source": "cybersecurity@se.com",
          "type": "Secondary"
        },
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-345"
            }
          ],
          "source": "nvd@nist.gov",
          "type": "Primary"
        }
      ]
    }

    CVE-2022-22806 (GCVE-0-2022-22806)

    Vulnerability from nvd – Published: 2022-03-09 19:30 – Updated: 2024-08-03 03:21
    VLAI
    Summary
    A CWE-294: Authentication Bypass by Capture-replay vulnerability exists that could cause an unauthenticated connection to the UPS when a malformed connection is sent. Affected Product: SmartConnect Family: SMT Series (SMT Series ID=1015: UPS 04.5 and prior), SMC Series (SMC Series ID=1018: UPS 04.2 and prior), SMTL Series (SMTL Series ID=1026: UPS 02.9 and prior), SCL Series (SCL Series ID=1029: UPS 02.5 and prior / SCL Series ID=1030: UPS 02.5 and prior / SCL Series ID=1036: UPS 02.5 and prior / SCL Series ID=1037: UPS 03.1 and prior), SMX Series (SMX Series ID=1031: UPS 03.1 and prior)
    Severity
    No CVSS data available.
    CWE
    • CWE-294 - Authentication Bypass by Capture-replay
    Assigner
    schneider CNA under the mitre root
    CNA scorecard C 65/100 over 20 records in the last 180 days details
    References
    Impacted products
    Vendor Product Version
    Schneider Electric SmartConnect Affected: SMT Series
    Affected: SMC Series
    Affected: SMTL Series
    Affected: SCL Series
    Affected: SMX Series
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T03:21:49.161Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.se.com/ww/en/download/document/SEVD-2022-067-02/"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "SmartConnect",
              "vendor": "Schneider Electric",
              "versions": [
                {
                  "status": "affected",
                  "version": "SMT Series"
                },
                {
                  "status": "affected",
                  "version": "SMC Series"
                },
                {
                  "status": "affected",
                  "version": "SMTL Series"
                },
                {
                  "status": "affected",
                  "version": "SCL Series"
                },
                {
                  "status": "affected",
                  "version": "SMX Series"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A CWE-294: Authentication Bypass by Capture-replay vulnerability exists that could cause an unauthenticated connection to the UPS when a malformed connection is sent. Affected Product: SmartConnect Family: SMT Series (SMT Series ID=1015: UPS 04.5 and prior), SMC Series (SMC Series ID=1018: UPS 04.2 and prior), SMTL Series (SMTL Series ID=1026: UPS 02.9 and prior), SCL Series (SCL Series ID=1029: UPS 02.5 and prior / SCL Series ID=1030: UPS 02.5 and prior / SCL Series ID=1036: UPS 02.5 and prior / SCL Series ID=1037: UPS 03.1 and prior), SMX Series (SMX Series ID=1031: UPS 03.1 and prior)"
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-294",
                  "description": "CWE-294 Authentication Bypass by Capture-replay",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2022-03-28T16:25:29.000Z",
            "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
            "shortName": "schneider"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.se.com/ww/en/download/document/SEVD-2022-067-02/"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "x_generator": {
            "engine": "Vulnogram 0.0.9"
          },
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cybersecurity@schneider-electric.com",
              "ID": "CVE-2022-22806",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "SmartConnect",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "SMT Series"
                              },
                              {
                                "version_value": "SMC Series"
                              },
                              {
                                "version_value": "SMTL Series"
                              },
                              {
                                "version_value": "SCL Series"
                              },
                              {
                                "version_value": "SMX Series"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "Schneider Electric"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "A CWE-294: Authentication Bypass by Capture-replay vulnerability exists that could cause an unauthenticated connection to the UPS when a malformed connection is sent. Affected Product: SmartConnect Family: SMT Series (SMT Series ID=1015: UPS 04.5 and prior), SMC Series (SMC Series ID=1018: UPS 04.2 and prior), SMTL Series (SMTL Series ID=1026: UPS 02.9 and prior), SCL Series (SCL Series ID=1029: UPS 02.5 and prior / SCL Series ID=1030: UPS 02.5 and prior / SCL Series ID=1036: UPS 02.5 and prior / SCL Series ID=1037: UPS 03.1 and prior), SMX Series (SMX Series ID=1031: UPS 03.1 and prior)"
                }
              ]
            },
            "generator": {
              "engine": "Vulnogram 0.0.9"
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-294 Authentication Bypass by Capture-replay"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.se.com/ww/en/download/document/SEVD-2022-067-02/",
                  "refsource": "MISC",
                  "url": "https://www.se.com/ww/en/download/document/SEVD-2022-067-02/"
                }
              ]
            },
            "source": {
              "discovery": "UNKNOWN"
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
        "assignerShortName": "schneider",
        "cveId": "CVE-2022-22806",
        "datePublished": "2022-03-09T19:30:17.000Z",
        "dateReserved": "2022-01-07T00:00:00.000Z",
        "dateUpdated": "2024-08-03T03:21:49.161Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2022-22805 (GCVE-0-2022-22805)

    Vulnerability from nvd – Published: 2022-03-09 19:30 – Updated: 2024-08-03 03:21
    VLAI
    Summary
    A CWE-120: Buffer Copy without Checking Size of Input ('Classic Buffer Overflow') vulnerability exists that could cause remote code execution when an improperly handled TLS packet is reassembled. Affected Product: SmartConnect Family: SMT Series (SMT Series ID=1015: UPS 04.5 and prior), SMC Series (SMC Series ID=1018: UPS 04.2 and prior), SMTL Series (SMTL Series ID=1026: UPS 02.9 and prior), SCL Series (SCL Series ID=1029: UPS 02.5 and prior / SCL Series ID=1030: UPS 02.5 and prior / SCL Series ID=1036: UPS 02.5 and prior / SCL Series ID=1037: UPS 03.1 and prior), SMX Series (SMX Series ID=1031: UPS 03.1 and prior)
    Severity
    No CVSS data available.
    CWE
    • CWE-120 - Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
    Assigner
    schneider CNA under the mitre root
    CNA scorecard C 65/100 over 20 records in the last 180 days details
    References
    Impacted products
    Vendor Product Version
    Schneider Electric SmartConnect Affected: SMT Series
    Affected: SMC Series
    Affected: SMTL Series
    Affected: SCL Series
    Affected: SMX Series
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T03:21:49.170Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.se.com/ww/en/download/document/SEVD-2022-067-02/"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "SmartConnect",
              "vendor": "Schneider Electric",
              "versions": [
                {
                  "status": "affected",
                  "version": "SMT Series"
                },
                {
                  "status": "affected",
                  "version": "SMC Series"
                },
                {
                  "status": "affected",
                  "version": "SMTL Series"
                },
                {
                  "status": "affected",
                  "version": "SCL Series"
                },
                {
                  "status": "affected",
                  "version": "SMX Series"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A CWE-120: Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027) vulnerability exists that could cause remote code execution when an improperly handled TLS packet is reassembled. Affected Product: SmartConnect Family: SMT Series (SMT Series ID=1015: UPS 04.5 and prior), SMC Series (SMC Series ID=1018: UPS 04.2 and prior), SMTL Series (SMTL Series ID=1026: UPS 02.9 and prior), SCL Series (SCL Series ID=1029: UPS 02.5 and prior / SCL Series ID=1030: UPS 02.5 and prior / SCL Series ID=1036: UPS 02.5 and prior / SCL Series ID=1037: UPS 03.1 and prior), SMX Series (SMX Series ID=1031: UPS 03.1 and prior)"
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-120",
                  "description": "CWE-120: Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2022-03-28T16:25:28.000Z",
            "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
            "shortName": "schneider"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.se.com/ww/en/download/document/SEVD-2022-067-02/"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "x_generator": {
            "engine": "Vulnogram 0.0.9"
          },
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cybersecurity@schneider-electric.com",
              "ID": "CVE-2022-22805",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "SmartConnect",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "SMT Series"
                              },
                              {
                                "version_value": "SMC Series"
                              },
                              {
                                "version_value": "SMTL Series"
                              },
                              {
                                "version_value": "SCL Series"
                              },
                              {
                                "version_value": "SMX Series"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "Schneider Electric"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "A CWE-120: Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027) vulnerability exists that could cause remote code execution when an improperly handled TLS packet is reassembled. Affected Product: SmartConnect Family: SMT Series (SMT Series ID=1015: UPS 04.5 and prior), SMC Series (SMC Series ID=1018: UPS 04.2 and prior), SMTL Series (SMTL Series ID=1026: UPS 02.9 and prior), SCL Series (SCL Series ID=1029: UPS 02.5 and prior / SCL Series ID=1030: UPS 02.5 and prior / SCL Series ID=1036: UPS 02.5 and prior / SCL Series ID=1037: UPS 03.1 and prior), SMX Series (SMX Series ID=1031: UPS 03.1 and prior)"
                }
              ]
            },
            "generator": {
              "engine": "Vulnogram 0.0.9"
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-120: Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027)"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.se.com/ww/en/download/document/SEVD-2022-067-02/",
                  "refsource": "MISC",
                  "url": "https://www.se.com/ww/en/download/document/SEVD-2022-067-02/"
                }
              ]
            },
            "source": {
              "discovery": "UNKNOWN"
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
        "assignerShortName": "schneider",
        "cveId": "CVE-2022-22805",
        "datePublished": "2022-03-09T19:30:16.000Z",
        "dateReserved": "2022-01-07T00:00:00.000Z",
        "dateUpdated": "2024-08-03T03:21:49.170Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2022-0715 (GCVE-0-2022-0715)

    Vulnerability from nvd – Published: 2022-03-09 19:30 – Updated: 2026-05-29 14:05
    VLAI
    Summary
    A CWE-287: Improper Authentication vulnerability exists that could cause an attacker to arbitrarily change the behavior of the UPS when a key is leaked and used to upload malicious firmware. Affected Product: APC Smart-UPS Family: SMT Series (SMT Series ID=18: UPS 09.8 and prior / SMT Series ID=1040: UPS 01.2 and prior / SMT Series ID=1031: UPS 03.1 and prior), SMC Series (SMC Series ID=1005: UPS 14.1 and prior / SMC Series ID=1007: UPS 11.0 and prior / SMC Series ID=1041: UPS 01.1 and prior), SCL Series (SCL Series ID=1030: UPS 02.5 and prior / SCL Series ID=1036: UPS 02.5 and prior), SMX Series (SMX Series ID=20: UPS 10.2 and prior / SMX Series ID=23: UPS 07.0 and prior), SRT Series (SRT Series ID=1010/1019/1025: UPS 08.3 and prior / SRT Series ID=1024: UPS 01.0 and prior / SRT Series ID=1020: UPS 10.4 and prior / SRT Series ID=1021: UPS 12.2 and prior / SRT Series ID=1001/1013: UPS 05.1 and prior / SRT Series ID=1002/1014: UPSa05.2 and prior), APC SmartConnect Family: SMT Series (SMT Series ID=1015: UPS 04.5 and prior), SMC Series (SMC Series ID=1018: UPS 04.2 and prior), SMTL Series (SMTL Series ID=1026: UPS 02.9 and prior), SCL Series (SCL Series ID=1029: UPS 02.5 and prior / SCL Series ID=1030: UPS 02.5 and prior / SCL Series ID=1036: UPS 02.5 and prior / SCL Series ID=1037: UPS 03.1 and prior), SMX Series (SMX Series ID=1031: UPS 03.1 and prior)
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-05-29 14:04 UTC
    CWE
    • CWE-287 - Improper Authentication
    Assigner
    schneider CNA under the mitre root
    CNA scorecard C 65/100 over 20 records in the last 180 days details
    References
    Impacted products
    Vendor Product Version
    Schneider Electric APC Smart-UPS Affected: SMT Series
    Affected: SMC Series
    Affected: SCL Series
    Affected: SMX Series
    Affected: SRT Series
    Create a notification for this product.
    Schneider Electric SmartConnect Affected: SMT Series
    Affected: SMC Series
    Affected: SMTL Series
    Affected: SCL Series
    Affected: SMX Series
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T23:40:03.366Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.se.com/ww/en/download/document/SEVD-2022-067-02/"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "cvssV3_1": {
                  "attackComplexity": "HIGH",
                  "attackVector": "NETWORK",
                  "availabilityImpact": "HIGH",
                  "baseScore": 8.9,
                  "baseSeverity": "HIGH",
                  "confidentialityImpact": "LOW",
                  "integrityImpact": "HIGH",
                  "privilegesRequired": "NONE",
                  "scope": "CHANGED",
                  "userInteraction": "NONE",
                  "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:C/C:L/I:H/A:H",
                  "version": "3.1"
                }
              },
              {
                "other": {
                  "content": {
                    "id": "CVE-2022-0715",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-05-29T14:04:24.695082Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-05-29T14:05:59.422Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "APC Smart-UPS",
              "vendor": "Schneider Electric",
              "versions": [
                {
                  "status": "affected",
                  "version": "SMT Series"
                },
                {
                  "status": "affected",
                  "version": "SMC Series"
                },
                {
                  "status": "affected",
                  "version": "SCL Series"
                },
                {
                  "status": "affected",
                  "version": "SMX Series"
                },
                {
                  "status": "affected",
                  "version": "SRT Series"
                }
              ]
            },
            {
              "product": "SmartConnect",
              "vendor": "Schneider Electric",
              "versions": [
                {
                  "status": "affected",
                  "version": "SMT Series"
                },
                {
                  "status": "affected",
                  "version": "SMC Series"
                },
                {
                  "status": "affected",
                  "version": "SMTL Series"
                },
                {
                  "status": "affected",
                  "version": "SCL Series"
                },
                {
                  "status": "affected",
                  "version": "SMX Series"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A CWE-287: Improper Authentication vulnerability exists that could cause an attacker to arbitrarily change the behavior of the UPS when a key is leaked and used to upload malicious firmware. Affected Product: APC Smart-UPS Family: SMT Series (SMT Series ID=18: UPS 09.8 and prior / SMT Series ID=1040: UPS 01.2 and prior / SMT Series ID=1031: UPS 03.1 and prior), SMC Series (SMC Series ID=1005: UPS 14.1 and prior / SMC Series ID=1007: UPS 11.0 and prior / SMC Series ID=1041: UPS 01.1 and prior), SCL Series (SCL Series ID=1030: UPS 02.5 and prior / SCL Series ID=1036: UPS 02.5 and prior), SMX Series (SMX Series ID=20: UPS 10.2 and prior / SMX Series ID=23: UPS 07.0 and prior), SRT Series (SRT Series ID=1010/1019/1025: UPS 08.3 and prior / SRT Series ID=1024: UPS 01.0 and prior / SRT Series ID=1020: UPS 10.4 and prior / SRT Series ID=1021: UPS 12.2 and prior / SRT Series ID=1001/1013: UPS 05.1 and prior / SRT Series ID=1002/1014: UPSa05.2 and prior), APC SmartConnect Family: SMT Series (SMT Series ID=1015: UPS 04.5 and prior), SMC Series (SMC Series ID=1018: UPS 04.2 and prior), SMTL Series (SMTL Series ID=1026: UPS 02.9 and prior), SCL Series (SCL Series ID=1029: UPS 02.5 and prior / SCL Series ID=1030: UPS 02.5 and prior / SCL Series ID=1036: UPS 02.5 and prior / SCL Series ID=1037: UPS 03.1 and prior), SMX Series (SMX Series ID=1031: UPS 03.1 and prior)"
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-287",
                  "description": "CWE-287 Improper Authentication",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2022-03-28T16:25:27.000Z",
            "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
            "shortName": "schneider"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.se.com/ww/en/download/document/SEVD-2022-067-02/"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "x_generator": {
            "engine": "Vulnogram 0.0.9"
          },
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cybersecurity@schneider-electric.com",
              "ID": "CVE-2022-0715",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "APC Smart-UPS",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "SMT Series"
                              },
                              {
                                "version_value": "SMC Series"
                              },
                              {
                                "version_value": "SCL Series"
                              },
                              {
                                "version_value": "SMX Series"
                              },
                              {
                                "version_value": "SRT Series"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "SmartConnect",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "SMT Series"
                              },
                              {
                                "version_value": "SMC Series"
                              },
                              {
                                "version_value": "SMTL Series"
                              },
                              {
                                "version_value": "SCL Series"
                              },
                              {
                                "version_value": "SMX Series"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "Schneider Electric"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "A CWE-287: Improper Authentication vulnerability exists that could cause an attacker to arbitrarily change the behavior of the UPS when a key is leaked and used to upload malicious firmware. Affected Product: APC Smart-UPS Family: SMT Series (SMT Series ID=18: UPS 09.8 and prior / SMT Series ID=1040: UPS 01.2 and prior / SMT Series ID=1031: UPS 03.1 and prior), SMC Series (SMC Series ID=1005: UPS 14.1 and prior / SMC Series ID=1007: UPS 11.0 and prior / SMC Series ID=1041: UPS 01.1 and prior), SCL Series (SCL Series ID=1030: UPS 02.5 and prior / SCL Series ID=1036: UPS 02.5 and prior), SMX Series (SMX Series ID=20: UPS 10.2 and prior / SMX Series ID=23: UPS 07.0 and prior), SRT Series (SRT Series ID=1010/1019/1025: UPS 08.3 and prior / SRT Series ID=1024: UPS 01.0 and prior / SRT Series ID=1020: UPS 10.4 and prior / SRT Series ID=1021: UPS 12.2 and prior / SRT Series ID=1001/1013: UPS 05.1 and prior / SRT Series ID=1002/1014: UPSa05.2 and prior), APC SmartConnect Family: SMT Series (SMT Series ID=1015: UPS 04.5 and prior), SMC Series (SMC Series ID=1018: UPS 04.2 and prior), SMTL Series (SMTL Series ID=1026: UPS 02.9 and prior), SCL Series (SCL Series ID=1029: UPS 02.5 and prior / SCL Series ID=1030: UPS 02.5 and prior / SCL Series ID=1036: UPS 02.5 and prior / SCL Series ID=1037: UPS 03.1 and prior), SMX Series (SMX Series ID=1031: UPS 03.1 and prior)"
                }
              ]
            },
            "generator": {
              "engine": "Vulnogram 0.0.9"
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-287 Improper Authentication"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.se.com/ww/en/download/document/SEVD-2022-067-02/",
                  "refsource": "MISC",
                  "url": "https://www.se.com/ww/en/download/document/SEVD-2022-067-02/"
                }
              ]
            },
            "source": {
              "discovery": "UNKNOWN"
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
        "assignerShortName": "schneider",
        "cveId": "CVE-2022-0715",
        "datePublished": "2022-03-09T19:30:14.000Z",
        "dateReserved": "2022-02-21T00:00:00.000Z",
        "dateUpdated": "2026-05-29T14:05:59.422Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2022-22806 (GCVE-0-2022-22806)

    Vulnerability from cvelistv5 – Published: 2022-03-09 19:30 – Updated: 2024-08-03 03:21
    VLAI
    Summary
    A CWE-294: Authentication Bypass by Capture-replay vulnerability exists that could cause an unauthenticated connection to the UPS when a malformed connection is sent. Affected Product: SmartConnect Family: SMT Series (SMT Series ID=1015: UPS 04.5 and prior), SMC Series (SMC Series ID=1018: UPS 04.2 and prior), SMTL Series (SMTL Series ID=1026: UPS 02.9 and prior), SCL Series (SCL Series ID=1029: UPS 02.5 and prior / SCL Series ID=1030: UPS 02.5 and prior / SCL Series ID=1036: UPS 02.5 and prior / SCL Series ID=1037: UPS 03.1 and prior), SMX Series (SMX Series ID=1031: UPS 03.1 and prior)
    Severity
    No CVSS data available.
    CWE
    • CWE-294 - Authentication Bypass by Capture-replay
    Assigner
    schneider CNA under the mitre root
    CNA scorecard C 65/100 over 20 records in the last 180 days details
    References
    Impacted products
    Vendor Product Version
    Schneider Electric SmartConnect Affected: SMT Series
    Affected: SMC Series
    Affected: SMTL Series
    Affected: SCL Series
    Affected: SMX Series
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T03:21:49.161Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.se.com/ww/en/download/document/SEVD-2022-067-02/"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "SmartConnect",
              "vendor": "Schneider Electric",
              "versions": [
                {
                  "status": "affected",
                  "version": "SMT Series"
                },
                {
                  "status": "affected",
                  "version": "SMC Series"
                },
                {
                  "status": "affected",
                  "version": "SMTL Series"
                },
                {
                  "status": "affected",
                  "version": "SCL Series"
                },
                {
                  "status": "affected",
                  "version": "SMX Series"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A CWE-294: Authentication Bypass by Capture-replay vulnerability exists that could cause an unauthenticated connection to the UPS when a malformed connection is sent. Affected Product: SmartConnect Family: SMT Series (SMT Series ID=1015: UPS 04.5 and prior), SMC Series (SMC Series ID=1018: UPS 04.2 and prior), SMTL Series (SMTL Series ID=1026: UPS 02.9 and prior), SCL Series (SCL Series ID=1029: UPS 02.5 and prior / SCL Series ID=1030: UPS 02.5 and prior / SCL Series ID=1036: UPS 02.5 and prior / SCL Series ID=1037: UPS 03.1 and prior), SMX Series (SMX Series ID=1031: UPS 03.1 and prior)"
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-294",
                  "description": "CWE-294 Authentication Bypass by Capture-replay",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2022-03-28T16:25:29.000Z",
            "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
            "shortName": "schneider"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.se.com/ww/en/download/document/SEVD-2022-067-02/"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "x_generator": {
            "engine": "Vulnogram 0.0.9"
          },
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cybersecurity@schneider-electric.com",
              "ID": "CVE-2022-22806",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "SmartConnect",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "SMT Series"
                              },
                              {
                                "version_value": "SMC Series"
                              },
                              {
                                "version_value": "SMTL Series"
                              },
                              {
                                "version_value": "SCL Series"
                              },
                              {
                                "version_value": "SMX Series"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "Schneider Electric"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "A CWE-294: Authentication Bypass by Capture-replay vulnerability exists that could cause an unauthenticated connection to the UPS when a malformed connection is sent. Affected Product: SmartConnect Family: SMT Series (SMT Series ID=1015: UPS 04.5 and prior), SMC Series (SMC Series ID=1018: UPS 04.2 and prior), SMTL Series (SMTL Series ID=1026: UPS 02.9 and prior), SCL Series (SCL Series ID=1029: UPS 02.5 and prior / SCL Series ID=1030: UPS 02.5 and prior / SCL Series ID=1036: UPS 02.5 and prior / SCL Series ID=1037: UPS 03.1 and prior), SMX Series (SMX Series ID=1031: UPS 03.1 and prior)"
                }
              ]
            },
            "generator": {
              "engine": "Vulnogram 0.0.9"
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-294 Authentication Bypass by Capture-replay"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.se.com/ww/en/download/document/SEVD-2022-067-02/",
                  "refsource": "MISC",
                  "url": "https://www.se.com/ww/en/download/document/SEVD-2022-067-02/"
                }
              ]
            },
            "source": {
              "discovery": "UNKNOWN"
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
        "assignerShortName": "schneider",
        "cveId": "CVE-2022-22806",
        "datePublished": "2022-03-09T19:30:17.000Z",
        "dateReserved": "2022-01-07T00:00:00.000Z",
        "dateUpdated": "2024-08-03T03:21:49.161Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2022-22805 (GCVE-0-2022-22805)

    Vulnerability from cvelistv5 – Published: 2022-03-09 19:30 – Updated: 2024-08-03 03:21
    VLAI
    Summary
    A CWE-120: Buffer Copy without Checking Size of Input ('Classic Buffer Overflow') vulnerability exists that could cause remote code execution when an improperly handled TLS packet is reassembled. Affected Product: SmartConnect Family: SMT Series (SMT Series ID=1015: UPS 04.5 and prior), SMC Series (SMC Series ID=1018: UPS 04.2 and prior), SMTL Series (SMTL Series ID=1026: UPS 02.9 and prior), SCL Series (SCL Series ID=1029: UPS 02.5 and prior / SCL Series ID=1030: UPS 02.5 and prior / SCL Series ID=1036: UPS 02.5 and prior / SCL Series ID=1037: UPS 03.1 and prior), SMX Series (SMX Series ID=1031: UPS 03.1 and prior)
    Severity
    No CVSS data available.
    CWE
    • CWE-120 - Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
    Assigner
    schneider CNA under the mitre root
    CNA scorecard C 65/100 over 20 records in the last 180 days details
    References
    Impacted products
    Vendor Product Version
    Schneider Electric SmartConnect Affected: SMT Series
    Affected: SMC Series
    Affected: SMTL Series
    Affected: SCL Series
    Affected: SMX Series
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T03:21:49.170Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.se.com/ww/en/download/document/SEVD-2022-067-02/"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "SmartConnect",
              "vendor": "Schneider Electric",
              "versions": [
                {
                  "status": "affected",
                  "version": "SMT Series"
                },
                {
                  "status": "affected",
                  "version": "SMC Series"
                },
                {
                  "status": "affected",
                  "version": "SMTL Series"
                },
                {
                  "status": "affected",
                  "version": "SCL Series"
                },
                {
                  "status": "affected",
                  "version": "SMX Series"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A CWE-120: Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027) vulnerability exists that could cause remote code execution when an improperly handled TLS packet is reassembled. Affected Product: SmartConnect Family: SMT Series (SMT Series ID=1015: UPS 04.5 and prior), SMC Series (SMC Series ID=1018: UPS 04.2 and prior), SMTL Series (SMTL Series ID=1026: UPS 02.9 and prior), SCL Series (SCL Series ID=1029: UPS 02.5 and prior / SCL Series ID=1030: UPS 02.5 and prior / SCL Series ID=1036: UPS 02.5 and prior / SCL Series ID=1037: UPS 03.1 and prior), SMX Series (SMX Series ID=1031: UPS 03.1 and prior)"
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-120",
                  "description": "CWE-120: Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2022-03-28T16:25:28.000Z",
            "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
            "shortName": "schneider"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.se.com/ww/en/download/document/SEVD-2022-067-02/"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "x_generator": {
            "engine": "Vulnogram 0.0.9"
          },
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cybersecurity@schneider-electric.com",
              "ID": "CVE-2022-22805",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "SmartConnect",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "SMT Series"
                              },
                              {
                                "version_value": "SMC Series"
                              },
                              {
                                "version_value": "SMTL Series"
                              },
                              {
                                "version_value": "SCL Series"
                              },
                              {
                                "version_value": "SMX Series"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "Schneider Electric"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "A CWE-120: Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027) vulnerability exists that could cause remote code execution when an improperly handled TLS packet is reassembled. Affected Product: SmartConnect Family: SMT Series (SMT Series ID=1015: UPS 04.5 and prior), SMC Series (SMC Series ID=1018: UPS 04.2 and prior), SMTL Series (SMTL Series ID=1026: UPS 02.9 and prior), SCL Series (SCL Series ID=1029: UPS 02.5 and prior / SCL Series ID=1030: UPS 02.5 and prior / SCL Series ID=1036: UPS 02.5 and prior / SCL Series ID=1037: UPS 03.1 and prior), SMX Series (SMX Series ID=1031: UPS 03.1 and prior)"
                }
              ]
            },
            "generator": {
              "engine": "Vulnogram 0.0.9"
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-120: Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027)"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.se.com/ww/en/download/document/SEVD-2022-067-02/",
                  "refsource": "MISC",
                  "url": "https://www.se.com/ww/en/download/document/SEVD-2022-067-02/"
                }
              ]
            },
            "source": {
              "discovery": "UNKNOWN"
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
        "assignerShortName": "schneider",
        "cveId": "CVE-2022-22805",
        "datePublished": "2022-03-09T19:30:16.000Z",
        "dateReserved": "2022-01-07T00:00:00.000Z",
        "dateUpdated": "2024-08-03T03:21:49.170Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2022-0715 (GCVE-0-2022-0715)

    Vulnerability from cvelistv5 – Published: 2022-03-09 19:30 – Updated: 2026-05-29 14:05
    VLAI
    Summary
    A CWE-287: Improper Authentication vulnerability exists that could cause an attacker to arbitrarily change the behavior of the UPS when a key is leaked and used to upload malicious firmware. Affected Product: APC Smart-UPS Family: SMT Series (SMT Series ID=18: UPS 09.8 and prior / SMT Series ID=1040: UPS 01.2 and prior / SMT Series ID=1031: UPS 03.1 and prior), SMC Series (SMC Series ID=1005: UPS 14.1 and prior / SMC Series ID=1007: UPS 11.0 and prior / SMC Series ID=1041: UPS 01.1 and prior), SCL Series (SCL Series ID=1030: UPS 02.5 and prior / SCL Series ID=1036: UPS 02.5 and prior), SMX Series (SMX Series ID=20: UPS 10.2 and prior / SMX Series ID=23: UPS 07.0 and prior), SRT Series (SRT Series ID=1010/1019/1025: UPS 08.3 and prior / SRT Series ID=1024: UPS 01.0 and prior / SRT Series ID=1020: UPS 10.4 and prior / SRT Series ID=1021: UPS 12.2 and prior / SRT Series ID=1001/1013: UPS 05.1 and prior / SRT Series ID=1002/1014: UPSa05.2 and prior), APC SmartConnect Family: SMT Series (SMT Series ID=1015: UPS 04.5 and prior), SMC Series (SMC Series ID=1018: UPS 04.2 and prior), SMTL Series (SMTL Series ID=1026: UPS 02.9 and prior), SCL Series (SCL Series ID=1029: UPS 02.5 and prior / SCL Series ID=1030: UPS 02.5 and prior / SCL Series ID=1036: UPS 02.5 and prior / SCL Series ID=1037: UPS 03.1 and prior), SMX Series (SMX Series ID=1031: UPS 03.1 and prior)
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-05-29 14:04 UTC
    CWE
    • CWE-287 - Improper Authentication
    Assigner
    schneider CNA under the mitre root
    CNA scorecard C 65/100 over 20 records in the last 180 days details
    References
    Impacted products
    Vendor Product Version
    Schneider Electric APC Smart-UPS Affected: SMT Series
    Affected: SMC Series
    Affected: SCL Series
    Affected: SMX Series
    Affected: SRT Series
    Create a notification for this product.
    Schneider Electric SmartConnect Affected: SMT Series
    Affected: SMC Series
    Affected: SMTL Series
    Affected: SCL Series
    Affected: SMX Series
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T23:40:03.366Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.se.com/ww/en/download/document/SEVD-2022-067-02/"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "cvssV3_1": {
                  "attackComplexity": "HIGH",
                  "attackVector": "NETWORK",
                  "availabilityImpact": "HIGH",
                  "baseScore": 8.9,
                  "baseSeverity": "HIGH",
                  "confidentialityImpact": "LOW",
                  "integrityImpact": "HIGH",
                  "privilegesRequired": "NONE",
                  "scope": "CHANGED",
                  "userInteraction": "NONE",
                  "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:C/C:L/I:H/A:H",
                  "version": "3.1"
                }
              },
              {
                "other": {
                  "content": {
                    "id": "CVE-2022-0715",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-05-29T14:04:24.695082Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-05-29T14:05:59.422Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "APC Smart-UPS",
              "vendor": "Schneider Electric",
              "versions": [
                {
                  "status": "affected",
                  "version": "SMT Series"
                },
                {
                  "status": "affected",
                  "version": "SMC Series"
                },
                {
                  "status": "affected",
                  "version": "SCL Series"
                },
                {
                  "status": "affected",
                  "version": "SMX Series"
                },
                {
                  "status": "affected",
                  "version": "SRT Series"
                }
              ]
            },
            {
              "product": "SmartConnect",
              "vendor": "Schneider Electric",
              "versions": [
                {
                  "status": "affected",
                  "version": "SMT Series"
                },
                {
                  "status": "affected",
                  "version": "SMC Series"
                },
                {
                  "status": "affected",
                  "version": "SMTL Series"
                },
                {
                  "status": "affected",
                  "version": "SCL Series"
                },
                {
                  "status": "affected",
                  "version": "SMX Series"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A CWE-287: Improper Authentication vulnerability exists that could cause an attacker to arbitrarily change the behavior of the UPS when a key is leaked and used to upload malicious firmware. Affected Product: APC Smart-UPS Family: SMT Series (SMT Series ID=18: UPS 09.8 and prior / SMT Series ID=1040: UPS 01.2 and prior / SMT Series ID=1031: UPS 03.1 and prior), SMC Series (SMC Series ID=1005: UPS 14.1 and prior / SMC Series ID=1007: UPS 11.0 and prior / SMC Series ID=1041: UPS 01.1 and prior), SCL Series (SCL Series ID=1030: UPS 02.5 and prior / SCL Series ID=1036: UPS 02.5 and prior), SMX Series (SMX Series ID=20: UPS 10.2 and prior / SMX Series ID=23: UPS 07.0 and prior), SRT Series (SRT Series ID=1010/1019/1025: UPS 08.3 and prior / SRT Series ID=1024: UPS 01.0 and prior / SRT Series ID=1020: UPS 10.4 and prior / SRT Series ID=1021: UPS 12.2 and prior / SRT Series ID=1001/1013: UPS 05.1 and prior / SRT Series ID=1002/1014: UPSa05.2 and prior), APC SmartConnect Family: SMT Series (SMT Series ID=1015: UPS 04.5 and prior), SMC Series (SMC Series ID=1018: UPS 04.2 and prior), SMTL Series (SMTL Series ID=1026: UPS 02.9 and prior), SCL Series (SCL Series ID=1029: UPS 02.5 and prior / SCL Series ID=1030: UPS 02.5 and prior / SCL Series ID=1036: UPS 02.5 and prior / SCL Series ID=1037: UPS 03.1 and prior), SMX Series (SMX Series ID=1031: UPS 03.1 and prior)"
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-287",
                  "description": "CWE-287 Improper Authentication",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2022-03-28T16:25:27.000Z",
            "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
            "shortName": "schneider"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.se.com/ww/en/download/document/SEVD-2022-067-02/"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "x_generator": {
            "engine": "Vulnogram 0.0.9"
          },
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cybersecurity@schneider-electric.com",
              "ID": "CVE-2022-0715",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "APC Smart-UPS",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "SMT Series"
                              },
                              {
                                "version_value": "SMC Series"
                              },
                              {
                                "version_value": "SCL Series"
                              },
                              {
                                "version_value": "SMX Series"
                              },
                              {
                                "version_value": "SRT Series"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "SmartConnect",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "SMT Series"
                              },
                              {
                                "version_value": "SMC Series"
                              },
                              {
                                "version_value": "SMTL Series"
                              },
                              {
                                "version_value": "SCL Series"
                              },
                              {
                                "version_value": "SMX Series"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "Schneider Electric"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "A CWE-287: Improper Authentication vulnerability exists that could cause an attacker to arbitrarily change the behavior of the UPS when a key is leaked and used to upload malicious firmware. Affected Product: APC Smart-UPS Family: SMT Series (SMT Series ID=18: UPS 09.8 and prior / SMT Series ID=1040: UPS 01.2 and prior / SMT Series ID=1031: UPS 03.1 and prior), SMC Series (SMC Series ID=1005: UPS 14.1 and prior / SMC Series ID=1007: UPS 11.0 and prior / SMC Series ID=1041: UPS 01.1 and prior), SCL Series (SCL Series ID=1030: UPS 02.5 and prior / SCL Series ID=1036: UPS 02.5 and prior), SMX Series (SMX Series ID=20: UPS 10.2 and prior / SMX Series ID=23: UPS 07.0 and prior), SRT Series (SRT Series ID=1010/1019/1025: UPS 08.3 and prior / SRT Series ID=1024: UPS 01.0 and prior / SRT Series ID=1020: UPS 10.4 and prior / SRT Series ID=1021: UPS 12.2 and prior / SRT Series ID=1001/1013: UPS 05.1 and prior / SRT Series ID=1002/1014: UPSa05.2 and prior), APC SmartConnect Family: SMT Series (SMT Series ID=1015: UPS 04.5 and prior), SMC Series (SMC Series ID=1018: UPS 04.2 and prior), SMTL Series (SMTL Series ID=1026: UPS 02.9 and prior), SCL Series (SCL Series ID=1029: UPS 02.5 and prior / SCL Series ID=1030: UPS 02.5 and prior / SCL Series ID=1036: UPS 02.5 and prior / SCL Series ID=1037: UPS 03.1 and prior), SMX Series (SMX Series ID=1031: UPS 03.1 and prior)"
                }
              ]
            },
            "generator": {
              "engine": "Vulnogram 0.0.9"
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-287 Improper Authentication"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.se.com/ww/en/download/document/SEVD-2022-067-02/",
                  "refsource": "MISC",
                  "url": "https://www.se.com/ww/en/download/document/SEVD-2022-067-02/"
                }
              ]
            },
            "source": {
              "discovery": "UNKNOWN"
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
        "assignerShortName": "schneider",
        "cveId": "CVE-2022-0715",
        "datePublished": "2022-03-09T19:30:14.000Z",
        "dateReserved": "2022-02-21T00:00:00.000Z",
        "dateUpdated": "2026-05-29T14:05:59.422Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }