Search

Find a vulnerability

Search criteria

    2 vulnerabilities found for siplus_cpu_1516-3_pn\/dp_firmware by siemens

    CVE-2020-28397 (GCVE-0-2020-28397)

    Vulnerability from nvd – Published: 2021-08-10 10:35 – Updated: 2024-08-04 16:33
    VLAI
    Summary
    A vulnerability has been identified in SIMATIC Drive Controller family (All versions < V2.9.2), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions < V21.9), SIMATIC S7 PLCSIM Advanced (All versions > V2 < V4), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (Version V4.4), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions > V2.5 < V2.9.2), SIMATIC S7-1500 Software Controller (All versions > V2.5 < V21.9), TIM 1531 IRC (incl. SIPLUS NET variants) (Version V2.1). Due to an incorrect authorization check in the affected component, an attacker could extract information about access protected PLC program variables over port 102/tcp from an affected device when reading multiple attributes at once.
    Severity
    No CVSS data available.
    CWE
    • CWE-863 - Incorrect Authorization
    Assigner
    References
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T16:33:59.119Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-865327.pdf"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "SIMATIC Drive Controller family",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003c V2.9.2"
                }
              ]
            },
            {
              "product": "SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants)",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003c V21.9"
                }
              ]
            },
            {
              "product": "SIMATIC S7 PLCSIM Advanced",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003e V2 \u003c V4"
                }
              ]
            },
            {
              "product": "SIMATIC S7-1200 CPU family (incl. SIPLUS variants)",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "Version V4.4"
                }
              ]
            },
            {
              "product": "SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants)",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003e V2.5 \u003c V2.9.2"
                }
              ]
            },
            {
              "product": "SIMATIC S7-1500 Software Controller",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003e V2.5 \u003c V21.9"
                }
              ]
            },
            {
              "product": "TIM 1531 IRC (incl. SIPLUS NET variants)",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "Version V2.1"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability has been identified in SIMATIC Drive Controller family (All versions \u003c V2.9.2), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions \u003c V21.9), SIMATIC S7 PLCSIM Advanced (All versions \u003e V2 \u003c V4), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (Version V4.4), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions \u003e V2.5 \u003c V2.9.2), SIMATIC S7-1500 Software Controller (All versions \u003e V2.5 \u003c V21.9), TIM 1531 IRC (incl. SIPLUS NET variants) (Version V2.1). Due to an incorrect authorization check in the affected component, an attacker could extract information about access protected PLC program variables over port 102/tcp from an affected device when reading multiple attributes at once."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-863",
                  "description": "CWE-863: Incorrect Authorization",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2021-09-14T10:47:15.000Z",
            "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
            "shortName": "siemens"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-865327.pdf"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "productcert@siemens.com",
              "ID": "CVE-2020-28397",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "SIMATIC Drive Controller family",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All versions \u003c V2.9.2"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants)",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All versions \u003c V21.9"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "SIMATIC S7 PLCSIM Advanced",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All versions \u003e V2 \u003c V4"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "SIMATIC S7-1200 CPU family (incl. SIPLUS variants)",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "Version V4.4"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants)",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All versions \u003e V2.5 \u003c V2.9.2"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "SIMATIC S7-1500 Software Controller",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All versions \u003e V2.5 \u003c V21.9"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "TIM 1531 IRC (incl. SIPLUS NET variants)",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "Version V2.1"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "Siemens"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "A vulnerability has been identified in SIMATIC Drive Controller family (All versions \u003c V2.9.2), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions \u003c V21.9), SIMATIC S7 PLCSIM Advanced (All versions \u003e V2 \u003c V4), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (Version V4.4), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions \u003e V2.5 \u003c V2.9.2), SIMATIC S7-1500 Software Controller (All versions \u003e V2.5 \u003c V21.9), TIM 1531 IRC (incl. SIPLUS NET variants) (Version V2.1). Due to an incorrect authorization check in the affected component, an attacker could extract information about access protected PLC program variables over port 102/tcp from an affected device when reading multiple attributes at once."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-863: Incorrect Authorization"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-865327.pdf",
                  "refsource": "MISC",
                  "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-865327.pdf"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "assignerShortName": "siemens",
        "cveId": "CVE-2020-28397",
        "datePublished": "2021-08-10T10:35:23.000Z",
        "dateReserved": "2020-11-10T00:00:00.000Z",
        "dateUpdated": "2024-08-04T16:33:59.119Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2020-28397 (GCVE-0-2020-28397)

    Vulnerability from cvelistv5 – Published: 2021-08-10 10:35 – Updated: 2024-08-04 16:33
    VLAI
    Summary
    A vulnerability has been identified in SIMATIC Drive Controller family (All versions < V2.9.2), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions < V21.9), SIMATIC S7 PLCSIM Advanced (All versions > V2 < V4), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (Version V4.4), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions > V2.5 < V2.9.2), SIMATIC S7-1500 Software Controller (All versions > V2.5 < V21.9), TIM 1531 IRC (incl. SIPLUS NET variants) (Version V2.1). Due to an incorrect authorization check in the affected component, an attacker could extract information about access protected PLC program variables over port 102/tcp from an affected device when reading multiple attributes at once.
    Severity
    No CVSS data available.
    CWE
    • CWE-863 - Incorrect Authorization
    Assigner
    References
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T16:33:59.119Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-865327.pdf"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "SIMATIC Drive Controller family",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003c V2.9.2"
                }
              ]
            },
            {
              "product": "SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants)",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003c V21.9"
                }
              ]
            },
            {
              "product": "SIMATIC S7 PLCSIM Advanced",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003e V2 \u003c V4"
                }
              ]
            },
            {
              "product": "SIMATIC S7-1200 CPU family (incl. SIPLUS variants)",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "Version V4.4"
                }
              ]
            },
            {
              "product": "SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants)",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003e V2.5 \u003c V2.9.2"
                }
              ]
            },
            {
              "product": "SIMATIC S7-1500 Software Controller",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003e V2.5 \u003c V21.9"
                }
              ]
            },
            {
              "product": "TIM 1531 IRC (incl. SIPLUS NET variants)",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "Version V2.1"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability has been identified in SIMATIC Drive Controller family (All versions \u003c V2.9.2), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions \u003c V21.9), SIMATIC S7 PLCSIM Advanced (All versions \u003e V2 \u003c V4), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (Version V4.4), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions \u003e V2.5 \u003c V2.9.2), SIMATIC S7-1500 Software Controller (All versions \u003e V2.5 \u003c V21.9), TIM 1531 IRC (incl. SIPLUS NET variants) (Version V2.1). Due to an incorrect authorization check in the affected component, an attacker could extract information about access protected PLC program variables over port 102/tcp from an affected device when reading multiple attributes at once."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-863",
                  "description": "CWE-863: Incorrect Authorization",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2021-09-14T10:47:15.000Z",
            "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
            "shortName": "siemens"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-865327.pdf"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "productcert@siemens.com",
              "ID": "CVE-2020-28397",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "SIMATIC Drive Controller family",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All versions \u003c V2.9.2"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants)",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All versions \u003c V21.9"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "SIMATIC S7 PLCSIM Advanced",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All versions \u003e V2 \u003c V4"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "SIMATIC S7-1200 CPU family (incl. SIPLUS variants)",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "Version V4.4"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants)",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All versions \u003e V2.5 \u003c V2.9.2"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "SIMATIC S7-1500 Software Controller",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All versions \u003e V2.5 \u003c V21.9"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "TIM 1531 IRC (incl. SIPLUS NET variants)",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "Version V2.1"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "Siemens"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "A vulnerability has been identified in SIMATIC Drive Controller family (All versions \u003c V2.9.2), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions \u003c V21.9), SIMATIC S7 PLCSIM Advanced (All versions \u003e V2 \u003c V4), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (Version V4.4), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions \u003e V2.5 \u003c V2.9.2), SIMATIC S7-1500 Software Controller (All versions \u003e V2.5 \u003c V21.9), TIM 1531 IRC (incl. SIPLUS NET variants) (Version V2.1). Due to an incorrect authorization check in the affected component, an attacker could extract information about access protected PLC program variables over port 102/tcp from an affected device when reading multiple attributes at once."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-863: Incorrect Authorization"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-865327.pdf",
                  "refsource": "MISC",
                  "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-865327.pdf"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "assignerShortName": "siemens",
        "cveId": "CVE-2020-28397",
        "datePublished": "2021-08-10T10:35:23.000Z",
        "dateReserved": "2020-11-10T00:00:00.000Z",
        "dateUpdated": "2024-08-04T16:33:59.119Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }