Search criteria
26 vulnerabilities found for sinumerik_pcu_base_win7_software\/ipc by siemens
CVE-2019-8272 (GCVE-0-2019-8272)
Vulnerability from cvelistv5 – Published: 2019-03-09 00:00 – Updated: 2024-09-16 16:43
VLAI?
Summary
UltraVNC revision 1211 has multiple off-by-one vulnerabilities in VNC server code, which can potentially result in code execution. This attack appears to be exploitable via network connectivity. These vulnerabilities have been fixed in revision 1212.
Severity ?
No CVSS data available.
CWE
- CWE-193 - Off-by-one Error
Assigner
References
| URL | Tags | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Kaspersky Lab | UltraVNC |
Affected:
1.2.2.3
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T21:17:30.483Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://ics-cert.kaspersky.com/advisories/klcert-advisories/2019/03/01/klcert-19-019-ultravnc-off-by-one-error/"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-927095.pdf"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.us-cert.gov/ics/advisories/icsa-20-161-06"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "UltraVNC",
"vendor": "Kaspersky Lab",
"versions": [
{
"status": "affected",
"version": "1.2.2.3"
}
]
}
],
"datePublic": "2019-03-01T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "UltraVNC revision 1211 has multiple off-by-one vulnerabilities in VNC server code, which can potentially result in code execution. This attack appears to be exploitable via network connectivity. These vulnerabilities have been fixed in revision 1212."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-193",
"description": "CWE-193: Off-by-one Error",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-06-12T20:54:20",
"orgId": "e45d732a-8f6b-4b6b-be76-7420f6a2b988",
"shortName": "Kaspersky"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://ics-cert.kaspersky.com/advisories/klcert-advisories/2019/03/01/klcert-19-019-ultravnc-off-by-one-error/"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-927095.pdf"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.us-cert.gov/ics/advisories/icsa-20-161-06"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "vulnerability@kaspersky.com",
"DATE_PUBLIC": "2019-03-01T00:00:00",
"ID": "CVE-2019-8272",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "UltraVNC",
"version": {
"version_data": [
{
"version_value": "1.2.2.3"
}
]
}
}
]
},
"vendor_name": "Kaspersky Lab"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "UltraVNC revision 1211 has multiple off-by-one vulnerabilities in VNC server code, which can potentially result in code execution. This attack appears to be exploitable via network connectivity. These vulnerabilities have been fixed in revision 1212."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-193: Off-by-one Error"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://ics-cert.kaspersky.com/advisories/klcert-advisories/2019/03/01/klcert-19-019-ultravnc-off-by-one-error/",
"refsource": "MISC",
"url": "https://ics-cert.kaspersky.com/advisories/klcert-advisories/2019/03/01/klcert-19-019-ultravnc-off-by-one-error/"
},
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-927095.pdf",
"refsource": "CONFIRM",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-927095.pdf"
},
{
"name": "https://www.us-cert.gov/ics/advisories/icsa-20-161-06",
"refsource": "MISC",
"url": "https://www.us-cert.gov/ics/advisories/icsa-20-161-06"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "e45d732a-8f6b-4b6b-be76-7420f6a2b988",
"assignerShortName": "Kaspersky",
"cveId": "CVE-2019-8272",
"datePublished": "2019-03-09T00:00:00Z",
"dateReserved": "2019-02-12T00:00:00",
"dateUpdated": "2024-09-16T16:43:07.206Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2019-8277 (GCVE-0-2019-8277)
Vulnerability from cvelistv5 – Published: 2019-03-09 00:00 – Updated: 2024-08-04 21:17
VLAI?
Summary
UltraVNC revision 1211 contains multiple memory leaks (CWE-665) in VNC server code, which allows an attacker to read stack memory and can be abused for information disclosure. Combined with another vulnerability, it can be used to leak stack memory and bypass ASLR. This attack appears to be exploitable via network connectivity. These vulnerabilities have been fixed in revision 1212.
Severity ?
No CVSS data available.
CWE
- CWE-665 - multiple memory leaks (CWE-665)
Assigner
References
| URL | Tags | |||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||||||||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Kaspersky Lab | UltraVNC |
Affected:
revision 1211
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T21:17:30.165Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://ics-cert.kaspersky.com/advisories/klcert-advisories/2019/03/01/klcert-19-024-ultravnc-improper-initialization/"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-927095.pdf"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.us-cert.gov/ics/advisories/icsa-20-161-06"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-940818.pdf"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-11"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "UltraVNC",
"vendor": "Kaspersky Lab",
"versions": [
{
"status": "affected",
"version": "revision 1211"
}
]
}
],
"datePublic": "2019-03-01T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "UltraVNC revision 1211 contains multiple memory leaks (CWE-665) in VNC server code, which allows an attacker to read stack memory and can be abused for information disclosure. Combined with another vulnerability, it can be used to leak stack memory and bypass ASLR. This attack appears to be exploitable via network connectivity. These vulnerabilities have been fixed in revision 1212."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-665",
"description": "multiple memory leaks (CWE-665)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-06-28T12:26:17",
"orgId": "e45d732a-8f6b-4b6b-be76-7420f6a2b988",
"shortName": "Kaspersky"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://ics-cert.kaspersky.com/advisories/klcert-advisories/2019/03/01/klcert-19-024-ultravnc-improper-initialization/"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-927095.pdf"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.us-cert.gov/ics/advisories/icsa-20-161-06"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-940818.pdf"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-11"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "vulnerability@kaspersky.com",
"ID": "CVE-2019-8277",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "UltraVNC",
"version": {
"version_data": [
{
"version_value": "revision 1211"
}
]
}
}
]
},
"vendor_name": "Kaspersky Lab"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "UltraVNC revision 1211 contains multiple memory leaks (CWE-665) in VNC server code, which allows an attacker to read stack memory and can be abused for information disclosure. Combined with another vulnerability, it can be used to leak stack memory and bypass ASLR. This attack appears to be exploitable via network connectivity. These vulnerabilities have been fixed in revision 1212."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "multiple memory leaks (CWE-665)"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://ics-cert.kaspersky.com/advisories/klcert-advisories/2019/03/01/klcert-19-024-ultravnc-improper-initialization/",
"refsource": "CONFIRM",
"url": "https://ics-cert.kaspersky.com/advisories/klcert-advisories/2019/03/01/klcert-19-024-ultravnc-improper-initialization/"
},
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-927095.pdf",
"refsource": "CONFIRM",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-927095.pdf"
},
{
"name": "https://www.us-cert.gov/ics/advisories/icsa-20-161-06",
"refsource": "MISC",
"url": "https://www.us-cert.gov/ics/advisories/icsa-20-161-06"
},
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-940818.pdf",
"refsource": "CONFIRM",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-940818.pdf"
},
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf",
"refsource": "CONFIRM",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf"
},
{
"name": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-11",
"refsource": "MISC",
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-11"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "e45d732a-8f6b-4b6b-be76-7420f6a2b988",
"assignerShortName": "Kaspersky",
"cveId": "CVE-2019-8277",
"datePublished": "2019-03-09T00:00:00",
"dateReserved": "2019-02-12T00:00:00",
"dateUpdated": "2024-08-04T21:17:30.165Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2019-8269 (GCVE-0-2019-8269)
Vulnerability from cvelistv5 – Published: 2019-03-09 00:00 – Updated: 2024-09-17 00:30
VLAI?
Summary
UltraVNC revision 1206 has stack-based Buffer overflow vulnerability in VNC client code inside FileTransfer module, which leads to a denial of service (DoS) condition. This attack appear to be exploitable via network connectivity. This vulnerability has been fixed in revision 1207.
Severity ?
No CVSS data available.
CWE
- CWE-121 - Stack-based Buffer Overflow
Assigner
References
| URL | Tags | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Kaspersky Lab | UltraVNC |
Affected:
1.2.2.3
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T21:17:30.516Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://ics-cert.kaspersky.com/advisories/klcert-advisories/2019/03/01/klcert-19-016-ultravnc-stack-based-buffer-overflow/"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-927095.pdf"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.us-cert.gov/ics/advisories/icsa-20-161-06"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "UltraVNC",
"vendor": "Kaspersky Lab",
"versions": [
{
"status": "affected",
"version": "1.2.2.3"
}
]
}
],
"datePublic": "2019-03-01T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "UltraVNC revision 1206 has stack-based Buffer overflow vulnerability in VNC client code inside FileTransfer module, which leads to a denial of service (DoS) condition. This attack appear to be exploitable via network connectivity. This vulnerability has been fixed in revision 1207."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "CWE-121: Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-06-12T20:52:57",
"orgId": "e45d732a-8f6b-4b6b-be76-7420f6a2b988",
"shortName": "Kaspersky"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://ics-cert.kaspersky.com/advisories/klcert-advisories/2019/03/01/klcert-19-016-ultravnc-stack-based-buffer-overflow/"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-927095.pdf"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.us-cert.gov/ics/advisories/icsa-20-161-06"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "vulnerability@kaspersky.com",
"DATE_PUBLIC": "2019-03-01T00:00:00",
"ID": "CVE-2019-8269",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "UltraVNC",
"version": {
"version_data": [
{
"version_value": "1.2.2.3"
}
]
}
}
]
},
"vendor_name": "Kaspersky Lab"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "UltraVNC revision 1206 has stack-based Buffer overflow vulnerability in VNC client code inside FileTransfer module, which leads to a denial of service (DoS) condition. This attack appear to be exploitable via network connectivity. This vulnerability has been fixed in revision 1207."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-121: Stack-based Buffer Overflow"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://ics-cert.kaspersky.com/advisories/klcert-advisories/2019/03/01/klcert-19-016-ultravnc-stack-based-buffer-overflow/",
"refsource": "MISC",
"url": "https://ics-cert.kaspersky.com/advisories/klcert-advisories/2019/03/01/klcert-19-016-ultravnc-stack-based-buffer-overflow/"
},
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-927095.pdf",
"refsource": "CONFIRM",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-927095.pdf"
},
{
"name": "https://www.us-cert.gov/ics/advisories/icsa-20-161-06",
"refsource": "MISC",
"url": "https://www.us-cert.gov/ics/advisories/icsa-20-161-06"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "e45d732a-8f6b-4b6b-be76-7420f6a2b988",
"assignerShortName": "Kaspersky",
"cveId": "CVE-2019-8269",
"datePublished": "2019-03-09T00:00:00Z",
"dateReserved": "2019-02-12T00:00:00",
"dateUpdated": "2024-09-17T00:30:43.266Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2019-8273 (GCVE-0-2019-8273)
Vulnerability from cvelistv5 – Published: 2019-03-09 00:00 – Updated: 2024-09-16 23:16
VLAI?
Summary
UltraVNC revision 1211 has a heap buffer overflow vulnerability in VNC server code inside file transfer request handler, which can potentially result in code execution. This attack appears to be exploitable via network connectivity. This vulnerability has been fixed in revision 1212.
Severity ?
No CVSS data available.
CWE
- CWE-122 - Heap-based Buffer Overflow
Assigner
References
| URL | Tags | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Kaspersky Lab | UltraVNC |
Affected:
1.2.2.3
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T21:17:31.298Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://ics-cert.kaspersky.com/advisories/klcert-advisories/2019/03/01/klcert-19-020-ultravnc-heap-based-buffer-overflow/"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-927095.pdf"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.us-cert.gov/ics/advisories/icsa-20-161-06"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "UltraVNC",
"vendor": "Kaspersky Lab",
"versions": [
{
"status": "affected",
"version": "1.2.2.3"
}
]
}
],
"datePublic": "2019-03-01T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "UltraVNC revision 1211 has a heap buffer overflow vulnerability in VNC server code inside file transfer request handler, which can potentially result in code execution. This attack appears to be exploitable via network connectivity. This vulnerability has been fixed in revision 1212."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-122",
"description": "CWE-122: Heap-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-06-12T20:54:47",
"orgId": "e45d732a-8f6b-4b6b-be76-7420f6a2b988",
"shortName": "Kaspersky"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://ics-cert.kaspersky.com/advisories/klcert-advisories/2019/03/01/klcert-19-020-ultravnc-heap-based-buffer-overflow/"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-927095.pdf"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.us-cert.gov/ics/advisories/icsa-20-161-06"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "vulnerability@kaspersky.com",
"DATE_PUBLIC": "2019-03-01T00:00:00",
"ID": "CVE-2019-8273",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "UltraVNC",
"version": {
"version_data": [
{
"version_value": "1.2.2.3"
}
]
}
}
]
},
"vendor_name": "Kaspersky Lab"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "UltraVNC revision 1211 has a heap buffer overflow vulnerability in VNC server code inside file transfer request handler, which can potentially result in code execution. This attack appears to be exploitable via network connectivity. This vulnerability has been fixed in revision 1212."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-122: Heap-based Buffer Overflow"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://ics-cert.kaspersky.com/advisories/klcert-advisories/2019/03/01/klcert-19-020-ultravnc-heap-based-buffer-overflow/",
"refsource": "MISC",
"url": "https://ics-cert.kaspersky.com/advisories/klcert-advisories/2019/03/01/klcert-19-020-ultravnc-heap-based-buffer-overflow/"
},
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-927095.pdf",
"refsource": "CONFIRM",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-927095.pdf"
},
{
"name": "https://www.us-cert.gov/ics/advisories/icsa-20-161-06",
"refsource": "MISC",
"url": "https://www.us-cert.gov/ics/advisories/icsa-20-161-06"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "e45d732a-8f6b-4b6b-be76-7420f6a2b988",
"assignerShortName": "Kaspersky",
"cveId": "CVE-2019-8273",
"datePublished": "2019-03-09T00:00:00Z",
"dateReserved": "2019-02-12T00:00:00",
"dateUpdated": "2024-09-16T23:16:03.189Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2019-8275 (GCVE-0-2019-8275)
Vulnerability from cvelistv5 – Published: 2019-03-09 00:00 – Updated: 2024-09-17 03:12
VLAI?
Summary
UltraVNC revision 1211 has multiple improper null termination vulnerabilities in VNC server code, which result in out-of-bound data being accessed by remote users. This attack appears to be exploitable via network connectivity. These vulnerabilities have been fixed in revision 1212.
Severity ?
No CVSS data available.
CWE
- CWE-170 - Improper Null Termination
Assigner
References
| URL | Tags | |||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||||||||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Kaspersky Lab | UltraVNC |
Affected:
1.2.2.3
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T21:17:30.848Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://ics-cert.kaspersky.com/advisories/klcert-advisories/2019/03/01/klcert-19-022-ultravnc-improper-null-termination/"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-927095.pdf"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.us-cert.gov/ics/advisories/icsa-20-161-06"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-940818.pdf"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-11"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "UltraVNC",
"vendor": "Kaspersky Lab",
"versions": [
{
"status": "affected",
"version": "1.2.2.3"
}
]
}
],
"datePublic": "2019-03-01T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "UltraVNC revision 1211 has multiple improper null termination vulnerabilities in VNC server code, which result in out-of-bound data being accessed by remote users. This attack appears to be exploitable via network connectivity. These vulnerabilities have been fixed in revision 1212."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-170",
"description": "CWE-170: Improper Null Termination",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-06-28T12:15:25",
"orgId": "e45d732a-8f6b-4b6b-be76-7420f6a2b988",
"shortName": "Kaspersky"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://ics-cert.kaspersky.com/advisories/klcert-advisories/2019/03/01/klcert-19-022-ultravnc-improper-null-termination/"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-927095.pdf"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.us-cert.gov/ics/advisories/icsa-20-161-06"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-940818.pdf"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-11"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "vulnerability@kaspersky.com",
"DATE_PUBLIC": "2019-03-01T00:00:00",
"ID": "CVE-2019-8275",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "UltraVNC",
"version": {
"version_data": [
{
"version_value": "1.2.2.3"
}
]
}
}
]
},
"vendor_name": "Kaspersky Lab"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "UltraVNC revision 1211 has multiple improper null termination vulnerabilities in VNC server code, which result in out-of-bound data being accessed by remote users. This attack appears to be exploitable via network connectivity. These vulnerabilities have been fixed in revision 1212."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-170: Improper Null Termination"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://ics-cert.kaspersky.com/advisories/klcert-advisories/2019/03/01/klcert-19-022-ultravnc-improper-null-termination/",
"refsource": "MISC",
"url": "https://ics-cert.kaspersky.com/advisories/klcert-advisories/2019/03/01/klcert-19-022-ultravnc-improper-null-termination/"
},
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-927095.pdf",
"refsource": "CONFIRM",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-927095.pdf"
},
{
"name": "https://www.us-cert.gov/ics/advisories/icsa-20-161-06",
"refsource": "MISC",
"url": "https://www.us-cert.gov/ics/advisories/icsa-20-161-06"
},
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-940818.pdf",
"refsource": "CONFIRM",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-940818.pdf"
},
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf",
"refsource": "CONFIRM",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf"
},
{
"name": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-11",
"refsource": "MISC",
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-11"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "e45d732a-8f6b-4b6b-be76-7420f6a2b988",
"assignerShortName": "Kaspersky",
"cveId": "CVE-2019-8275",
"datePublished": "2019-03-09T00:00:00Z",
"dateReserved": "2019-02-12T00:00:00",
"dateUpdated": "2024-09-17T03:12:37.776Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2019-8268 (GCVE-0-2019-8268)
Vulnerability from cvelistv5 – Published: 2019-03-09 00:00 – Updated: 2024-09-17 01:16
VLAI?
Summary
UltraVNC revision 1206 has multiple off-by-one vulnerabilities in VNC client code connected with improper usage of ClientConnection::ReadString function, which can potentially result code execution. This attack appears to be exploitable via network connectivity. These vulnerabilities have been fixed in revision 1207.
Severity ?
No CVSS data available.
CWE
- CWE-193 - Off-by-one Error
Assigner
References
| URL | Tags | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Kaspersky Lab | UltraVNC |
Affected:
1.2.2.3
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T21:17:30.455Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://ics-cert.kaspersky.com/advisories/klcert-advisories/2019/03/01/klcert-19-015-ultravnc-off-by-one-error/"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-927095.pdf"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.us-cert.gov/ics/advisories/icsa-20-161-06"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "UltraVNC",
"vendor": "Kaspersky Lab",
"versions": [
{
"status": "affected",
"version": "1.2.2.3"
}
]
}
],
"datePublic": "2019-03-01T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "UltraVNC revision 1206 has multiple off-by-one vulnerabilities in VNC client code connected with improper usage of ClientConnection::ReadString function, which can potentially result code execution. This attack appears to be exploitable via network connectivity. These vulnerabilities have been fixed in revision 1207."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-193",
"description": "CWE-193: Off-by-one Error",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-06-12T20:52:16",
"orgId": "e45d732a-8f6b-4b6b-be76-7420f6a2b988",
"shortName": "Kaspersky"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://ics-cert.kaspersky.com/advisories/klcert-advisories/2019/03/01/klcert-19-015-ultravnc-off-by-one-error/"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-927095.pdf"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.us-cert.gov/ics/advisories/icsa-20-161-06"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "vulnerability@kaspersky.com",
"DATE_PUBLIC": "2019-03-01T00:00:00",
"ID": "CVE-2019-8268",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "UltraVNC",
"version": {
"version_data": [
{
"version_value": "1.2.2.3"
}
]
}
}
]
},
"vendor_name": "Kaspersky Lab"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "UltraVNC revision 1206 has multiple off-by-one vulnerabilities in VNC client code connected with improper usage of ClientConnection::ReadString function, which can potentially result code execution. This attack appears to be exploitable via network connectivity. These vulnerabilities have been fixed in revision 1207."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-193: Off-by-one Error"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://ics-cert.kaspersky.com/advisories/klcert-advisories/2019/03/01/klcert-19-015-ultravnc-off-by-one-error/",
"refsource": "MISC",
"url": "https://ics-cert.kaspersky.com/advisories/klcert-advisories/2019/03/01/klcert-19-015-ultravnc-off-by-one-error/"
},
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-927095.pdf",
"refsource": "CONFIRM",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-927095.pdf"
},
{
"name": "https://www.us-cert.gov/ics/advisories/icsa-20-161-06",
"refsource": "MISC",
"url": "https://www.us-cert.gov/ics/advisories/icsa-20-161-06"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "e45d732a-8f6b-4b6b-be76-7420f6a2b988",
"assignerShortName": "Kaspersky",
"cveId": "CVE-2019-8268",
"datePublished": "2019-03-09T00:00:00Z",
"dateReserved": "2019-02-12T00:00:00",
"dateUpdated": "2024-09-17T01:16:16.319Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2019-8271 (GCVE-0-2019-8271)
Vulnerability from cvelistv5 – Published: 2019-03-09 00:00 – Updated: 2024-09-16 23:26
VLAI?
Summary
UltraVNC revision 1211 has a heap buffer overflow vulnerability in VNC server code inside file transfer handler, which can potentially result code execution. This attack appears to be exploitable via network connectivity. This vulnerability has been fixed in revision 1212.
Severity ?
No CVSS data available.
CWE
- CWE-122 - Heap-based Buffer Overflow
Assigner
References
| URL | Tags | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Kaspersky Lab | UltraVNC |
Affected:
1.2.2.3
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T21:17:31.251Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://ics-cert.kaspersky.com/advisories/klcert-advisories/2019/03/01/klcert-19-018-ultravnc-heap-based-buffer-overflow/"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-927095.pdf"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.us-cert.gov/ics/advisories/icsa-20-161-06"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "UltraVNC",
"vendor": "Kaspersky Lab",
"versions": [
{
"status": "affected",
"version": "1.2.2.3"
}
]
}
],
"datePublic": "2019-03-01T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "UltraVNC revision 1211 has a heap buffer overflow vulnerability in VNC server code inside file transfer handler, which can potentially result code execution. This attack appears to be exploitable via network connectivity. This vulnerability has been fixed in revision 1212."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-122",
"description": "CWE-122: Heap-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-06-12T20:53:56",
"orgId": "e45d732a-8f6b-4b6b-be76-7420f6a2b988",
"shortName": "Kaspersky"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://ics-cert.kaspersky.com/advisories/klcert-advisories/2019/03/01/klcert-19-018-ultravnc-heap-based-buffer-overflow/"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-927095.pdf"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.us-cert.gov/ics/advisories/icsa-20-161-06"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "vulnerability@kaspersky.com",
"DATE_PUBLIC": "2019-03-01T00:00:00",
"ID": "CVE-2019-8271",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "UltraVNC",
"version": {
"version_data": [
{
"version_value": "1.2.2.3"
}
]
}
}
]
},
"vendor_name": "Kaspersky Lab"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "UltraVNC revision 1211 has a heap buffer overflow vulnerability in VNC server code inside file transfer handler, which can potentially result code execution. This attack appears to be exploitable via network connectivity. This vulnerability has been fixed in revision 1212."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-122: Heap-based Buffer Overflow"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://ics-cert.kaspersky.com/advisories/klcert-advisories/2019/03/01/klcert-19-018-ultravnc-heap-based-buffer-overflow/",
"refsource": "MISC",
"url": "https://ics-cert.kaspersky.com/advisories/klcert-advisories/2019/03/01/klcert-19-018-ultravnc-heap-based-buffer-overflow/"
},
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-927095.pdf",
"refsource": "CONFIRM",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-927095.pdf"
},
{
"name": "https://www.us-cert.gov/ics/advisories/icsa-20-161-06",
"refsource": "MISC",
"url": "https://www.us-cert.gov/ics/advisories/icsa-20-161-06"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "e45d732a-8f6b-4b6b-be76-7420f6a2b988",
"assignerShortName": "Kaspersky",
"cveId": "CVE-2019-8271",
"datePublished": "2019-03-09T00:00:00Z",
"dateReserved": "2019-02-12T00:00:00",
"dateUpdated": "2024-09-16T23:26:16.493Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2019-8274 (GCVE-0-2019-8274)
Vulnerability from cvelistv5 – Published: 2019-03-09 00:00 – Updated: 2024-09-16 19:35
VLAI?
Summary
UltraVNC revision 1211 has a heap buffer overflow vulnerability in VNC server code inside file transfer offer handler, which can potentially in result code execution. This attack appears to be exploitable via network connectivity. This vulnerability has been fixed in revision 1212.
Severity ?
No CVSS data available.
CWE
- CWE-122 - Heap-based Buffer Overflow
Assigner
References
| URL | Tags | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Kaspersky Lab | UltraVNC |
Affected:
1.2.2.3
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T21:17:30.639Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://ics-cert.kaspersky.com/advisories/klcert-advisories/2019/03/01/klcert-19-021-ultravnc-heap-based-buffer-overflow/"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-927095.pdf"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.us-cert.gov/ics/advisories/icsa-20-161-06"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "UltraVNC",
"vendor": "Kaspersky Lab",
"versions": [
{
"status": "affected",
"version": "1.2.2.3"
}
]
}
],
"datePublic": "2019-03-01T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "UltraVNC revision 1211 has a heap buffer overflow vulnerability in VNC server code inside file transfer offer handler, which can potentially in result code execution. This attack appears to be exploitable via network connectivity. This vulnerability has been fixed in revision 1212."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-122",
"description": "CWE-122: Heap-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-06-12T20:55:11",
"orgId": "e45d732a-8f6b-4b6b-be76-7420f6a2b988",
"shortName": "Kaspersky"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://ics-cert.kaspersky.com/advisories/klcert-advisories/2019/03/01/klcert-19-021-ultravnc-heap-based-buffer-overflow/"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-927095.pdf"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.us-cert.gov/ics/advisories/icsa-20-161-06"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "vulnerability@kaspersky.com",
"DATE_PUBLIC": "2019-03-01T00:00:00",
"ID": "CVE-2019-8274",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "UltraVNC",
"version": {
"version_data": [
{
"version_value": "1.2.2.3"
}
]
}
}
]
},
"vendor_name": "Kaspersky Lab"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "UltraVNC revision 1211 has a heap buffer overflow vulnerability in VNC server code inside file transfer offer handler, which can potentially in result code execution. This attack appears to be exploitable via network connectivity. This vulnerability has been fixed in revision 1212."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-122: Heap-based Buffer Overflow"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://ics-cert.kaspersky.com/advisories/klcert-advisories/2019/03/01/klcert-19-021-ultravnc-heap-based-buffer-overflow/",
"refsource": "MISC",
"url": "https://ics-cert.kaspersky.com/advisories/klcert-advisories/2019/03/01/klcert-19-021-ultravnc-heap-based-buffer-overflow/"
},
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-927095.pdf",
"refsource": "CONFIRM",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-927095.pdf"
},
{
"name": "https://www.us-cert.gov/ics/advisories/icsa-20-161-06",
"refsource": "MISC",
"url": "https://www.us-cert.gov/ics/advisories/icsa-20-161-06"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "e45d732a-8f6b-4b6b-be76-7420f6a2b988",
"assignerShortName": "Kaspersky",
"cveId": "CVE-2019-8274",
"datePublished": "2019-03-09T00:00:00Z",
"dateReserved": "2019-02-12T00:00:00",
"dateUpdated": "2024-09-16T19:35:36.652Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2019-8276 (GCVE-0-2019-8276)
Vulnerability from cvelistv5 – Published: 2019-03-09 00:00 – Updated: 2024-09-16 18:33
VLAI?
Summary
UltraVNC revision 1211 has a stack buffer overflow vulnerability in VNC server code inside file transfer request handler, which can result in Denial of Service (DoS). This attack appears to be exploitable via network connectivity. This vulnerability has been fixed in revision 1212.
Severity ?
No CVSS data available.
CWE
- CWE-121 - Stack-based Buffer Overflow
Assigner
References
| URL | Tags | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Kaspersky Lab | UltraVNC |
Affected:
1.2.2.3
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T21:17:30.806Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://ics-cert.kaspersky.com/advisories/klcert-advisories/2019/03/01/klcert-19-023-ultravnc-stack-based-buffer-overflow/"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-927095.pdf"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.us-cert.gov/ics/advisories/icsa-20-161-06"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "UltraVNC",
"vendor": "Kaspersky Lab",
"versions": [
{
"status": "affected",
"version": "1.2.2.3"
}
]
}
],
"datePublic": "2019-03-01T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "UltraVNC revision 1211 has a stack buffer overflow vulnerability in VNC server code inside file transfer request handler, which can result in Denial of Service (DoS). This attack appears to be exploitable via network connectivity. This vulnerability has been fixed in revision 1212."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "CWE-121: Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-06-12T20:55:54",
"orgId": "e45d732a-8f6b-4b6b-be76-7420f6a2b988",
"shortName": "Kaspersky"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://ics-cert.kaspersky.com/advisories/klcert-advisories/2019/03/01/klcert-19-023-ultravnc-stack-based-buffer-overflow/"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-927095.pdf"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.us-cert.gov/ics/advisories/icsa-20-161-06"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "vulnerability@kaspersky.com",
"DATE_PUBLIC": "2019-03-01T00:00:00",
"ID": "CVE-2019-8276",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "UltraVNC",
"version": {
"version_data": [
{
"version_value": "1.2.2.3"
}
]
}
}
]
},
"vendor_name": "Kaspersky Lab"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "UltraVNC revision 1211 has a stack buffer overflow vulnerability in VNC server code inside file transfer request handler, which can result in Denial of Service (DoS). This attack appears to be exploitable via network connectivity. This vulnerability has been fixed in revision 1212."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-121: Stack-based Buffer Overflow"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://ics-cert.kaspersky.com/advisories/klcert-advisories/2019/03/01/klcert-19-023-ultravnc-stack-based-buffer-overflow/",
"refsource": "MISC",
"url": "https://ics-cert.kaspersky.com/advisories/klcert-advisories/2019/03/01/klcert-19-023-ultravnc-stack-based-buffer-overflow/"
},
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-927095.pdf",
"refsource": "CONFIRM",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-927095.pdf"
},
{
"name": "https://www.us-cert.gov/ics/advisories/icsa-20-161-06",
"refsource": "MISC",
"url": "https://www.us-cert.gov/ics/advisories/icsa-20-161-06"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "e45d732a-8f6b-4b6b-be76-7420f6a2b988",
"assignerShortName": "Kaspersky",
"cveId": "CVE-2019-8276",
"datePublished": "2019-03-09T00:00:00Z",
"dateReserved": "2019-02-12T00:00:00",
"dateUpdated": "2024-09-16T18:33:31.486Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2019-8262 (GCVE-0-2019-8262)
Vulnerability from cvelistv5 – Published: 2019-03-05 15:00 – Updated: 2024-09-16 16:49
VLAI?
Summary
UltraVNC revision 1203 has multiple heap buffer overflow vulnerabilities in VNC client code inside Ultra decoder, which results in code execution. This attack appears to be exploitable via network connectivity. These vulnerabilities have been fixed in revision 1204.
Severity ?
No CVSS data available.
CWE
- CWE-122 - Heap-based Buffer Overflow
Assigner
References
| URL | Tags | |||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T21:17:30.593Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://ics-cert.kaspersky.com/advisories/klcert-advisories/2019/03/01/klcert-19-008-ultravnc-heap-based-buffer-overflow/"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-927095.pdf"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.us-cert.gov/ics/advisories/icsa-20-161-06"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-940818.pdf"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-11"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "UltraVNC",
"vendor": "UltraVNC",
"versions": [
{
"status": "affected",
"version": "1.2.2.3"
}
]
}
],
"datePublic": "2019-03-01T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "UltraVNC revision 1203 has multiple heap buffer overflow vulnerabilities in VNC client code inside Ultra decoder, which results in code execution. This attack appears to be exploitable via network connectivity. These vulnerabilities have been fixed in revision 1204."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-122",
"description": "CWE-122: Heap-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-06-28T11:52:18",
"orgId": "e45d732a-8f6b-4b6b-be76-7420f6a2b988",
"shortName": "Kaspersky"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://ics-cert.kaspersky.com/advisories/klcert-advisories/2019/03/01/klcert-19-008-ultravnc-heap-based-buffer-overflow/"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-927095.pdf"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.us-cert.gov/ics/advisories/icsa-20-161-06"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-940818.pdf"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-11"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "vulnerability@kaspersky.com",
"DATE_PUBLIC": "2019-03-01T00:00:00",
"ID": "CVE-2019-8262",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "UltraVNC",
"version": {
"version_data": [
{
"version_value": "1.2.2.3"
}
]
}
}
]
},
"vendor_name": "UltraVNC"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "UltraVNC revision 1203 has multiple heap buffer overflow vulnerabilities in VNC client code inside Ultra decoder, which results in code execution. This attack appears to be exploitable via network connectivity. These vulnerabilities have been fixed in revision 1204."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-122: Heap-based Buffer Overflow"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://ics-cert.kaspersky.com/advisories/klcert-advisories/2019/03/01/klcert-19-008-ultravnc-heap-based-buffer-overflow/",
"refsource": "MISC",
"url": "https://ics-cert.kaspersky.com/advisories/klcert-advisories/2019/03/01/klcert-19-008-ultravnc-heap-based-buffer-overflow/"
},
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-927095.pdf",
"refsource": "CONFIRM",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-927095.pdf"
},
{
"name": "https://www.us-cert.gov/ics/advisories/icsa-20-161-06",
"refsource": "MISC",
"url": "https://www.us-cert.gov/ics/advisories/icsa-20-161-06"
},
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-940818.pdf",
"refsource": "CONFIRM",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-940818.pdf"
},
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf",
"refsource": "CONFIRM",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf"
},
{
"name": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-11",
"refsource": "MISC",
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-11"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "e45d732a-8f6b-4b6b-be76-7420f6a2b988",
"assignerShortName": "Kaspersky",
"cveId": "CVE-2019-8262",
"datePublished": "2019-03-05T15:00:00Z",
"dateReserved": "2019-02-12T00:00:00",
"dateUpdated": "2024-09-16T16:49:03.600Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2019-8258 (GCVE-0-2019-8258)
Vulnerability from cvelistv5 – Published: 2019-03-05 15:00 – Updated: 2024-09-16 19:15
VLAI?
Summary
UltraVNC revision 1198 has a heap buffer overflow vulnerability in VNC client code which results code execution. This attack appears to be exploitable via network connectivity. This vulnerability has been fixed in revision 1199.
Severity ?
No CVSS data available.
CWE
- CWE-122 - Heap-based Buffer Overflow
Assigner
References
| URL | Tags | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T21:17:30.160Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://ics-cert.kaspersky.com/advisories/klcert-advisories/2019/03/01/klcert-19-004-ultravnc-heap-based-buffer-overflow/"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-927095.pdf"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.us-cert.gov/ics/advisories/icsa-20-161-06"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "UltraVNC",
"vendor": "UltraVNC",
"versions": [
{
"status": "affected",
"version": "1.2.2.3"
}
]
}
],
"datePublic": "2019-03-01T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "UltraVNC revision 1198 has a heap buffer overflow vulnerability in VNC client code which results code execution. This attack appears to be exploitable via network connectivity. This vulnerability has been fixed in revision 1199."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-122",
"description": "CWE-122: Heap-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-06-10T21:33:11",
"orgId": "e45d732a-8f6b-4b6b-be76-7420f6a2b988",
"shortName": "Kaspersky"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://ics-cert.kaspersky.com/advisories/klcert-advisories/2019/03/01/klcert-19-004-ultravnc-heap-based-buffer-overflow/"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-927095.pdf"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.us-cert.gov/ics/advisories/icsa-20-161-06"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "vulnerability@kaspersky.com",
"DATE_PUBLIC": "2019-03-01T00:00:00",
"ID": "CVE-2019-8258",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "UltraVNC",
"version": {
"version_data": [
{
"version_value": "1.2.2.3"
}
]
}
}
]
},
"vendor_name": "UltraVNC"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "UltraVNC revision 1198 has a heap buffer overflow vulnerability in VNC client code which results code execution. This attack appears to be exploitable via network connectivity. This vulnerability has been fixed in revision 1199."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-122: Heap-based Buffer Overflow"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://ics-cert.kaspersky.com/advisories/klcert-advisories/2019/03/01/klcert-19-004-ultravnc-heap-based-buffer-overflow/",
"refsource": "MISC",
"url": "https://ics-cert.kaspersky.com/advisories/klcert-advisories/2019/03/01/klcert-19-004-ultravnc-heap-based-buffer-overflow/"
},
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-927095.pdf",
"refsource": "CONFIRM",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-927095.pdf"
},
{
"name": "https://www.us-cert.gov/ics/advisories/icsa-20-161-06",
"refsource": "MISC",
"url": "https://www.us-cert.gov/ics/advisories/icsa-20-161-06"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "e45d732a-8f6b-4b6b-be76-7420f6a2b988",
"assignerShortName": "Kaspersky",
"cveId": "CVE-2019-8258",
"datePublished": "2019-03-05T15:00:00Z",
"dateReserved": "2019-02-12T00:00:00",
"dateUpdated": "2024-09-16T19:15:25.845Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2019-8259 (GCVE-0-2019-8259)
Vulnerability from cvelistv5 – Published: 2019-03-05 15:00 – Updated: 2024-09-16 20:59
VLAI?
Summary
UltraVNC revision 1198 contains multiple memory leaks (CWE-655) in VNC client code, which allow an attacker to read stack memory and can be abused for information disclosure. Combined with another vulnerability, it can be used to leak stack memory and bypass ASLR. This attack appears to be exploitable via network connectivity. These vulnerabilities have been fixed in revision 1199.
Severity ?
No CVSS data available.
CWE
- CWE-665 - Improper Initialization
Assigner
References
| URL | Tags | |||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T21:17:30.187Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://ics-cert.kaspersky.com/advisories/klcert-advisories/2019/03/01/klcert-19-005-ultravnc-memory-leak/"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-927095.pdf"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.us-cert.gov/ics/advisories/icsa-20-161-06"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-940818.pdf"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-11"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "UltraVNC",
"vendor": "UltraVNC",
"versions": [
{
"status": "affected",
"version": "1.2.2.3"
}
]
}
],
"datePublic": "2019-03-01T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "UltraVNC revision 1198 contains multiple memory leaks (CWE-655) in VNC client code, which allow an attacker to read stack memory and can be abused for information disclosure. Combined with another vulnerability, it can be used to leak stack memory and bypass ASLR. This attack appears to be exploitable via network connectivity. These vulnerabilities have been fixed in revision 1199."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-665",
"description": "CWE-665: Improper Initialization",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-06-28T12:10:55",
"orgId": "e45d732a-8f6b-4b6b-be76-7420f6a2b988",
"shortName": "Kaspersky"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://ics-cert.kaspersky.com/advisories/klcert-advisories/2019/03/01/klcert-19-005-ultravnc-memory-leak/"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-927095.pdf"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.us-cert.gov/ics/advisories/icsa-20-161-06"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-940818.pdf"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-11"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "vulnerability@kaspersky.com",
"DATE_PUBLIC": "2019-03-01T00:00:00",
"ID": "CVE-2019-8259",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "UltraVNC",
"version": {
"version_data": [
{
"version_value": "1.2.2.3"
}
]
}
}
]
},
"vendor_name": "UltraVNC"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "UltraVNC revision 1198 contains multiple memory leaks (CWE-655) in VNC client code, which allow an attacker to read stack memory and can be abused for information disclosure. Combined with another vulnerability, it can be used to leak stack memory and bypass ASLR. This attack appears to be exploitable via network connectivity. These vulnerabilities have been fixed in revision 1199."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-665: Improper Initialization"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://ics-cert.kaspersky.com/advisories/klcert-advisories/2019/03/01/klcert-19-005-ultravnc-memory-leak/",
"refsource": "MISC",
"url": "https://ics-cert.kaspersky.com/advisories/klcert-advisories/2019/03/01/klcert-19-005-ultravnc-memory-leak/"
},
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-927095.pdf",
"refsource": "CONFIRM",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-927095.pdf"
},
{
"name": "https://www.us-cert.gov/ics/advisories/icsa-20-161-06",
"refsource": "MISC",
"url": "https://www.us-cert.gov/ics/advisories/icsa-20-161-06"
},
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-940818.pdf",
"refsource": "CONFIRM",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-940818.pdf"
},
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf",
"refsource": "CONFIRM",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf"
},
{
"name": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-11",
"refsource": "MISC",
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-11"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "e45d732a-8f6b-4b6b-be76-7420f6a2b988",
"assignerShortName": "Kaspersky",
"cveId": "CVE-2019-8259",
"datePublished": "2019-03-05T15:00:00Z",
"dateReserved": "2019-02-12T00:00:00",
"dateUpdated": "2024-09-16T20:59:11.748Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2019-8263 (GCVE-0-2019-8263)
Vulnerability from cvelistv5 – Published: 2019-03-05 15:00 – Updated: 2024-09-16 23:56
VLAI?
Summary
UltraVNC revision 1205 has stack-based buffer overflow vulnerability in VNC client code inside ShowConnInfo routine, which leads to a denial of service (DoS) condition. This attack appear to be exploitable via network connectivity. User interaction is required to trigger this vulnerability. This vulnerability has been fixed in revision 1206.
Severity ?
No CVSS data available.
CWE
- CWE-121 - Stack-based Buffer Overflow
Assigner
References
| URL | Tags | ||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||||||||||||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Kaspersky Lab | UltraVNC |
Affected:
1.2.2.3
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T21:17:30.560Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://ics-cert.kaspersky.com/advisories/klcert-advisories/2019/03/01/klcert-19-009-ultravnc-access-of-memory-location-after-end-of-buffer/"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://ics-cert.kaspersky.com/advisories/klcert-advisories/2019/03/01/klcert-19-010-ultravnc-stack-based-buffer-overflow/"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-927095.pdf"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.us-cert.gov/ics/advisories/icsa-20-161-06"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-940818.pdf"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-11"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "UltraVNC",
"vendor": "Kaspersky Lab",
"versions": [
{
"status": "affected",
"version": "1.2.2.3"
}
]
}
],
"datePublic": "2019-03-01T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "UltraVNC revision 1205 has stack-based buffer overflow vulnerability in VNC client code inside ShowConnInfo routine, which leads to a denial of service (DoS) condition. This attack appear to be exploitable via network connectivity. User interaction is required to trigger this vulnerability. This vulnerability has been fixed in revision 1206."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "CWE-121: Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-06-28T11:53:57",
"orgId": "e45d732a-8f6b-4b6b-be76-7420f6a2b988",
"shortName": "Kaspersky"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://ics-cert.kaspersky.com/advisories/klcert-advisories/2019/03/01/klcert-19-009-ultravnc-access-of-memory-location-after-end-of-buffer/"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://ics-cert.kaspersky.com/advisories/klcert-advisories/2019/03/01/klcert-19-010-ultravnc-stack-based-buffer-overflow/"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-927095.pdf"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.us-cert.gov/ics/advisories/icsa-20-161-06"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-940818.pdf"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-11"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "vulnerability@kaspersky.com",
"DATE_PUBLIC": "2019-03-01T00:00:00",
"ID": "CVE-2019-8263",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "UltraVNC",
"version": {
"version_data": [
{
"version_value": "1.2.2.3"
}
]
}
}
]
},
"vendor_name": "Kaspersky Lab"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "UltraVNC revision 1205 has stack-based buffer overflow vulnerability in VNC client code inside ShowConnInfo routine, which leads to a denial of service (DoS) condition. This attack appear to be exploitable via network connectivity. User interaction is required to trigger this vulnerability. This vulnerability has been fixed in revision 1206."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-121: Stack-based Buffer Overflow"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://ics-cert.kaspersky.com/advisories/klcert-advisories/2019/03/01/klcert-19-009-ultravnc-access-of-memory-location-after-end-of-buffer/",
"refsource": "MISC",
"url": "https://ics-cert.kaspersky.com/advisories/klcert-advisories/2019/03/01/klcert-19-009-ultravnc-access-of-memory-location-after-end-of-buffer/"
},
{
"name": "https://ics-cert.kaspersky.com/advisories/klcert-advisories/2019/03/01/klcert-19-010-ultravnc-stack-based-buffer-overflow/",
"refsource": "MISC",
"url": "https://ics-cert.kaspersky.com/advisories/klcert-advisories/2019/03/01/klcert-19-010-ultravnc-stack-based-buffer-overflow/"
},
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-927095.pdf",
"refsource": "CONFIRM",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-927095.pdf"
},
{
"name": "https://www.us-cert.gov/ics/advisories/icsa-20-161-06",
"refsource": "MISC",
"url": "https://www.us-cert.gov/ics/advisories/icsa-20-161-06"
},
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-940818.pdf",
"refsource": "CONFIRM",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-940818.pdf"
},
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf",
"refsource": "CONFIRM",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf"
},
{
"name": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-11",
"refsource": "MISC",
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-11"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "e45d732a-8f6b-4b6b-be76-7420f6a2b988",
"assignerShortName": "Kaspersky",
"cveId": "CVE-2019-8263",
"datePublished": "2019-03-05T15:00:00Z",
"dateReserved": "2019-02-12T00:00:00",
"dateUpdated": "2024-09-16T23:56:07.697Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2019-8277 (GCVE-0-2019-8277)
Vulnerability from nvd – Published: 2019-03-09 00:00 – Updated: 2024-08-04 21:17
VLAI?
Summary
UltraVNC revision 1211 contains multiple memory leaks (CWE-665) in VNC server code, which allows an attacker to read stack memory and can be abused for information disclosure. Combined with another vulnerability, it can be used to leak stack memory and bypass ASLR. This attack appears to be exploitable via network connectivity. These vulnerabilities have been fixed in revision 1212.
Severity ?
No CVSS data available.
CWE
- CWE-665 - multiple memory leaks (CWE-665)
Assigner
References
| URL | Tags | |||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||||||||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Kaspersky Lab | UltraVNC |
Affected:
revision 1211
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T21:17:30.165Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://ics-cert.kaspersky.com/advisories/klcert-advisories/2019/03/01/klcert-19-024-ultravnc-improper-initialization/"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-927095.pdf"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.us-cert.gov/ics/advisories/icsa-20-161-06"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-940818.pdf"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-11"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "UltraVNC",
"vendor": "Kaspersky Lab",
"versions": [
{
"status": "affected",
"version": "revision 1211"
}
]
}
],
"datePublic": "2019-03-01T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "UltraVNC revision 1211 contains multiple memory leaks (CWE-665) in VNC server code, which allows an attacker to read stack memory and can be abused for information disclosure. Combined with another vulnerability, it can be used to leak stack memory and bypass ASLR. This attack appears to be exploitable via network connectivity. These vulnerabilities have been fixed in revision 1212."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-665",
"description": "multiple memory leaks (CWE-665)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-06-28T12:26:17",
"orgId": "e45d732a-8f6b-4b6b-be76-7420f6a2b988",
"shortName": "Kaspersky"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://ics-cert.kaspersky.com/advisories/klcert-advisories/2019/03/01/klcert-19-024-ultravnc-improper-initialization/"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-927095.pdf"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.us-cert.gov/ics/advisories/icsa-20-161-06"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-940818.pdf"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-11"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "vulnerability@kaspersky.com",
"ID": "CVE-2019-8277",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "UltraVNC",
"version": {
"version_data": [
{
"version_value": "revision 1211"
}
]
}
}
]
},
"vendor_name": "Kaspersky Lab"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "UltraVNC revision 1211 contains multiple memory leaks (CWE-665) in VNC server code, which allows an attacker to read stack memory and can be abused for information disclosure. Combined with another vulnerability, it can be used to leak stack memory and bypass ASLR. This attack appears to be exploitable via network connectivity. These vulnerabilities have been fixed in revision 1212."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "multiple memory leaks (CWE-665)"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://ics-cert.kaspersky.com/advisories/klcert-advisories/2019/03/01/klcert-19-024-ultravnc-improper-initialization/",
"refsource": "CONFIRM",
"url": "https://ics-cert.kaspersky.com/advisories/klcert-advisories/2019/03/01/klcert-19-024-ultravnc-improper-initialization/"
},
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-927095.pdf",
"refsource": "CONFIRM",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-927095.pdf"
},
{
"name": "https://www.us-cert.gov/ics/advisories/icsa-20-161-06",
"refsource": "MISC",
"url": "https://www.us-cert.gov/ics/advisories/icsa-20-161-06"
},
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-940818.pdf",
"refsource": "CONFIRM",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-940818.pdf"
},
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf",
"refsource": "CONFIRM",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf"
},
{
"name": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-11",
"refsource": "MISC",
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-11"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "e45d732a-8f6b-4b6b-be76-7420f6a2b988",
"assignerShortName": "Kaspersky",
"cveId": "CVE-2019-8277",
"datePublished": "2019-03-09T00:00:00",
"dateReserved": "2019-02-12T00:00:00",
"dateUpdated": "2024-08-04T21:17:30.165Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2019-8276 (GCVE-0-2019-8276)
Vulnerability from nvd – Published: 2019-03-09 00:00 – Updated: 2024-09-16 18:33
VLAI?
Summary
UltraVNC revision 1211 has a stack buffer overflow vulnerability in VNC server code inside file transfer request handler, which can result in Denial of Service (DoS). This attack appears to be exploitable via network connectivity. This vulnerability has been fixed in revision 1212.
Severity ?
No CVSS data available.
CWE
- CWE-121 - Stack-based Buffer Overflow
Assigner
References
| URL | Tags | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Kaspersky Lab | UltraVNC |
Affected:
1.2.2.3
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T21:17:30.806Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://ics-cert.kaspersky.com/advisories/klcert-advisories/2019/03/01/klcert-19-023-ultravnc-stack-based-buffer-overflow/"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-927095.pdf"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.us-cert.gov/ics/advisories/icsa-20-161-06"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "UltraVNC",
"vendor": "Kaspersky Lab",
"versions": [
{
"status": "affected",
"version": "1.2.2.3"
}
]
}
],
"datePublic": "2019-03-01T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "UltraVNC revision 1211 has a stack buffer overflow vulnerability in VNC server code inside file transfer request handler, which can result in Denial of Service (DoS). This attack appears to be exploitable via network connectivity. This vulnerability has been fixed in revision 1212."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "CWE-121: Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-06-12T20:55:54",
"orgId": "e45d732a-8f6b-4b6b-be76-7420f6a2b988",
"shortName": "Kaspersky"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://ics-cert.kaspersky.com/advisories/klcert-advisories/2019/03/01/klcert-19-023-ultravnc-stack-based-buffer-overflow/"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-927095.pdf"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.us-cert.gov/ics/advisories/icsa-20-161-06"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "vulnerability@kaspersky.com",
"DATE_PUBLIC": "2019-03-01T00:00:00",
"ID": "CVE-2019-8276",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "UltraVNC",
"version": {
"version_data": [
{
"version_value": "1.2.2.3"
}
]
}
}
]
},
"vendor_name": "Kaspersky Lab"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "UltraVNC revision 1211 has a stack buffer overflow vulnerability in VNC server code inside file transfer request handler, which can result in Denial of Service (DoS). This attack appears to be exploitable via network connectivity. This vulnerability has been fixed in revision 1212."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-121: Stack-based Buffer Overflow"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://ics-cert.kaspersky.com/advisories/klcert-advisories/2019/03/01/klcert-19-023-ultravnc-stack-based-buffer-overflow/",
"refsource": "MISC",
"url": "https://ics-cert.kaspersky.com/advisories/klcert-advisories/2019/03/01/klcert-19-023-ultravnc-stack-based-buffer-overflow/"
},
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-927095.pdf",
"refsource": "CONFIRM",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-927095.pdf"
},
{
"name": "https://www.us-cert.gov/ics/advisories/icsa-20-161-06",
"refsource": "MISC",
"url": "https://www.us-cert.gov/ics/advisories/icsa-20-161-06"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "e45d732a-8f6b-4b6b-be76-7420f6a2b988",
"assignerShortName": "Kaspersky",
"cveId": "CVE-2019-8276",
"datePublished": "2019-03-09T00:00:00Z",
"dateReserved": "2019-02-12T00:00:00",
"dateUpdated": "2024-09-16T18:33:31.486Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2019-8275 (GCVE-0-2019-8275)
Vulnerability from nvd – Published: 2019-03-09 00:00 – Updated: 2024-09-17 03:12
VLAI?
Summary
UltraVNC revision 1211 has multiple improper null termination vulnerabilities in VNC server code, which result in out-of-bound data being accessed by remote users. This attack appears to be exploitable via network connectivity. These vulnerabilities have been fixed in revision 1212.
Severity ?
No CVSS data available.
CWE
- CWE-170 - Improper Null Termination
Assigner
References
| URL | Tags | |||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||||||||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Kaspersky Lab | UltraVNC |
Affected:
1.2.2.3
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T21:17:30.848Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://ics-cert.kaspersky.com/advisories/klcert-advisories/2019/03/01/klcert-19-022-ultravnc-improper-null-termination/"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-927095.pdf"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.us-cert.gov/ics/advisories/icsa-20-161-06"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-940818.pdf"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-11"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "UltraVNC",
"vendor": "Kaspersky Lab",
"versions": [
{
"status": "affected",
"version": "1.2.2.3"
}
]
}
],
"datePublic": "2019-03-01T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "UltraVNC revision 1211 has multiple improper null termination vulnerabilities in VNC server code, which result in out-of-bound data being accessed by remote users. This attack appears to be exploitable via network connectivity. These vulnerabilities have been fixed in revision 1212."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-170",
"description": "CWE-170: Improper Null Termination",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-06-28T12:15:25",
"orgId": "e45d732a-8f6b-4b6b-be76-7420f6a2b988",
"shortName": "Kaspersky"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://ics-cert.kaspersky.com/advisories/klcert-advisories/2019/03/01/klcert-19-022-ultravnc-improper-null-termination/"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-927095.pdf"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.us-cert.gov/ics/advisories/icsa-20-161-06"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-940818.pdf"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-11"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "vulnerability@kaspersky.com",
"DATE_PUBLIC": "2019-03-01T00:00:00",
"ID": "CVE-2019-8275",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "UltraVNC",
"version": {
"version_data": [
{
"version_value": "1.2.2.3"
}
]
}
}
]
},
"vendor_name": "Kaspersky Lab"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "UltraVNC revision 1211 has multiple improper null termination vulnerabilities in VNC server code, which result in out-of-bound data being accessed by remote users. This attack appears to be exploitable via network connectivity. These vulnerabilities have been fixed in revision 1212."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-170: Improper Null Termination"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://ics-cert.kaspersky.com/advisories/klcert-advisories/2019/03/01/klcert-19-022-ultravnc-improper-null-termination/",
"refsource": "MISC",
"url": "https://ics-cert.kaspersky.com/advisories/klcert-advisories/2019/03/01/klcert-19-022-ultravnc-improper-null-termination/"
},
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-927095.pdf",
"refsource": "CONFIRM",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-927095.pdf"
},
{
"name": "https://www.us-cert.gov/ics/advisories/icsa-20-161-06",
"refsource": "MISC",
"url": "https://www.us-cert.gov/ics/advisories/icsa-20-161-06"
},
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-940818.pdf",
"refsource": "CONFIRM",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-940818.pdf"
},
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf",
"refsource": "CONFIRM",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf"
},
{
"name": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-11",
"refsource": "MISC",
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-11"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "e45d732a-8f6b-4b6b-be76-7420f6a2b988",
"assignerShortName": "Kaspersky",
"cveId": "CVE-2019-8275",
"datePublished": "2019-03-09T00:00:00Z",
"dateReserved": "2019-02-12T00:00:00",
"dateUpdated": "2024-09-17T03:12:37.776Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2019-8274 (GCVE-0-2019-8274)
Vulnerability from nvd – Published: 2019-03-09 00:00 – Updated: 2024-09-16 19:35
VLAI?
Summary
UltraVNC revision 1211 has a heap buffer overflow vulnerability in VNC server code inside file transfer offer handler, which can potentially in result code execution. This attack appears to be exploitable via network connectivity. This vulnerability has been fixed in revision 1212.
Severity ?
No CVSS data available.
CWE
- CWE-122 - Heap-based Buffer Overflow
Assigner
References
| URL | Tags | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Kaspersky Lab | UltraVNC |
Affected:
1.2.2.3
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T21:17:30.639Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://ics-cert.kaspersky.com/advisories/klcert-advisories/2019/03/01/klcert-19-021-ultravnc-heap-based-buffer-overflow/"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-927095.pdf"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.us-cert.gov/ics/advisories/icsa-20-161-06"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "UltraVNC",
"vendor": "Kaspersky Lab",
"versions": [
{
"status": "affected",
"version": "1.2.2.3"
}
]
}
],
"datePublic": "2019-03-01T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "UltraVNC revision 1211 has a heap buffer overflow vulnerability in VNC server code inside file transfer offer handler, which can potentially in result code execution. This attack appears to be exploitable via network connectivity. This vulnerability has been fixed in revision 1212."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-122",
"description": "CWE-122: Heap-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-06-12T20:55:11",
"orgId": "e45d732a-8f6b-4b6b-be76-7420f6a2b988",
"shortName": "Kaspersky"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://ics-cert.kaspersky.com/advisories/klcert-advisories/2019/03/01/klcert-19-021-ultravnc-heap-based-buffer-overflow/"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-927095.pdf"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.us-cert.gov/ics/advisories/icsa-20-161-06"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "vulnerability@kaspersky.com",
"DATE_PUBLIC": "2019-03-01T00:00:00",
"ID": "CVE-2019-8274",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "UltraVNC",
"version": {
"version_data": [
{
"version_value": "1.2.2.3"
}
]
}
}
]
},
"vendor_name": "Kaspersky Lab"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "UltraVNC revision 1211 has a heap buffer overflow vulnerability in VNC server code inside file transfer offer handler, which can potentially in result code execution. This attack appears to be exploitable via network connectivity. This vulnerability has been fixed in revision 1212."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-122: Heap-based Buffer Overflow"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://ics-cert.kaspersky.com/advisories/klcert-advisories/2019/03/01/klcert-19-021-ultravnc-heap-based-buffer-overflow/",
"refsource": "MISC",
"url": "https://ics-cert.kaspersky.com/advisories/klcert-advisories/2019/03/01/klcert-19-021-ultravnc-heap-based-buffer-overflow/"
},
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-927095.pdf",
"refsource": "CONFIRM",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-927095.pdf"
},
{
"name": "https://www.us-cert.gov/ics/advisories/icsa-20-161-06",
"refsource": "MISC",
"url": "https://www.us-cert.gov/ics/advisories/icsa-20-161-06"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "e45d732a-8f6b-4b6b-be76-7420f6a2b988",
"assignerShortName": "Kaspersky",
"cveId": "CVE-2019-8274",
"datePublished": "2019-03-09T00:00:00Z",
"dateReserved": "2019-02-12T00:00:00",
"dateUpdated": "2024-09-16T19:35:36.652Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2019-8273 (GCVE-0-2019-8273)
Vulnerability from nvd – Published: 2019-03-09 00:00 – Updated: 2024-09-16 23:16
VLAI?
Summary
UltraVNC revision 1211 has a heap buffer overflow vulnerability in VNC server code inside file transfer request handler, which can potentially result in code execution. This attack appears to be exploitable via network connectivity. This vulnerability has been fixed in revision 1212.
Severity ?
No CVSS data available.
CWE
- CWE-122 - Heap-based Buffer Overflow
Assigner
References
| URL | Tags | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Kaspersky Lab | UltraVNC |
Affected:
1.2.2.3
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T21:17:31.298Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://ics-cert.kaspersky.com/advisories/klcert-advisories/2019/03/01/klcert-19-020-ultravnc-heap-based-buffer-overflow/"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-927095.pdf"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.us-cert.gov/ics/advisories/icsa-20-161-06"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "UltraVNC",
"vendor": "Kaspersky Lab",
"versions": [
{
"status": "affected",
"version": "1.2.2.3"
}
]
}
],
"datePublic": "2019-03-01T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "UltraVNC revision 1211 has a heap buffer overflow vulnerability in VNC server code inside file transfer request handler, which can potentially result in code execution. This attack appears to be exploitable via network connectivity. This vulnerability has been fixed in revision 1212."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-122",
"description": "CWE-122: Heap-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-06-12T20:54:47",
"orgId": "e45d732a-8f6b-4b6b-be76-7420f6a2b988",
"shortName": "Kaspersky"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://ics-cert.kaspersky.com/advisories/klcert-advisories/2019/03/01/klcert-19-020-ultravnc-heap-based-buffer-overflow/"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-927095.pdf"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.us-cert.gov/ics/advisories/icsa-20-161-06"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "vulnerability@kaspersky.com",
"DATE_PUBLIC": "2019-03-01T00:00:00",
"ID": "CVE-2019-8273",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "UltraVNC",
"version": {
"version_data": [
{
"version_value": "1.2.2.3"
}
]
}
}
]
},
"vendor_name": "Kaspersky Lab"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "UltraVNC revision 1211 has a heap buffer overflow vulnerability in VNC server code inside file transfer request handler, which can potentially result in code execution. This attack appears to be exploitable via network connectivity. This vulnerability has been fixed in revision 1212."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-122: Heap-based Buffer Overflow"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://ics-cert.kaspersky.com/advisories/klcert-advisories/2019/03/01/klcert-19-020-ultravnc-heap-based-buffer-overflow/",
"refsource": "MISC",
"url": "https://ics-cert.kaspersky.com/advisories/klcert-advisories/2019/03/01/klcert-19-020-ultravnc-heap-based-buffer-overflow/"
},
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-927095.pdf",
"refsource": "CONFIRM",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-927095.pdf"
},
{
"name": "https://www.us-cert.gov/ics/advisories/icsa-20-161-06",
"refsource": "MISC",
"url": "https://www.us-cert.gov/ics/advisories/icsa-20-161-06"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "e45d732a-8f6b-4b6b-be76-7420f6a2b988",
"assignerShortName": "Kaspersky",
"cveId": "CVE-2019-8273",
"datePublished": "2019-03-09T00:00:00Z",
"dateReserved": "2019-02-12T00:00:00",
"dateUpdated": "2024-09-16T23:16:03.189Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2019-8272 (GCVE-0-2019-8272)
Vulnerability from nvd – Published: 2019-03-09 00:00 – Updated: 2024-09-16 16:43
VLAI?
Summary
UltraVNC revision 1211 has multiple off-by-one vulnerabilities in VNC server code, which can potentially result in code execution. This attack appears to be exploitable via network connectivity. These vulnerabilities have been fixed in revision 1212.
Severity ?
No CVSS data available.
CWE
- CWE-193 - Off-by-one Error
Assigner
References
| URL | Tags | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Kaspersky Lab | UltraVNC |
Affected:
1.2.2.3
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T21:17:30.483Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://ics-cert.kaspersky.com/advisories/klcert-advisories/2019/03/01/klcert-19-019-ultravnc-off-by-one-error/"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-927095.pdf"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.us-cert.gov/ics/advisories/icsa-20-161-06"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "UltraVNC",
"vendor": "Kaspersky Lab",
"versions": [
{
"status": "affected",
"version": "1.2.2.3"
}
]
}
],
"datePublic": "2019-03-01T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "UltraVNC revision 1211 has multiple off-by-one vulnerabilities in VNC server code, which can potentially result in code execution. This attack appears to be exploitable via network connectivity. These vulnerabilities have been fixed in revision 1212."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-193",
"description": "CWE-193: Off-by-one Error",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-06-12T20:54:20",
"orgId": "e45d732a-8f6b-4b6b-be76-7420f6a2b988",
"shortName": "Kaspersky"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://ics-cert.kaspersky.com/advisories/klcert-advisories/2019/03/01/klcert-19-019-ultravnc-off-by-one-error/"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-927095.pdf"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.us-cert.gov/ics/advisories/icsa-20-161-06"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "vulnerability@kaspersky.com",
"DATE_PUBLIC": "2019-03-01T00:00:00",
"ID": "CVE-2019-8272",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "UltraVNC",
"version": {
"version_data": [
{
"version_value": "1.2.2.3"
}
]
}
}
]
},
"vendor_name": "Kaspersky Lab"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "UltraVNC revision 1211 has multiple off-by-one vulnerabilities in VNC server code, which can potentially result in code execution. This attack appears to be exploitable via network connectivity. These vulnerabilities have been fixed in revision 1212."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-193: Off-by-one Error"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://ics-cert.kaspersky.com/advisories/klcert-advisories/2019/03/01/klcert-19-019-ultravnc-off-by-one-error/",
"refsource": "MISC",
"url": "https://ics-cert.kaspersky.com/advisories/klcert-advisories/2019/03/01/klcert-19-019-ultravnc-off-by-one-error/"
},
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-927095.pdf",
"refsource": "CONFIRM",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-927095.pdf"
},
{
"name": "https://www.us-cert.gov/ics/advisories/icsa-20-161-06",
"refsource": "MISC",
"url": "https://www.us-cert.gov/ics/advisories/icsa-20-161-06"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "e45d732a-8f6b-4b6b-be76-7420f6a2b988",
"assignerShortName": "Kaspersky",
"cveId": "CVE-2019-8272",
"datePublished": "2019-03-09T00:00:00Z",
"dateReserved": "2019-02-12T00:00:00",
"dateUpdated": "2024-09-16T16:43:07.206Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2019-8271 (GCVE-0-2019-8271)
Vulnerability from nvd – Published: 2019-03-09 00:00 – Updated: 2024-09-16 23:26
VLAI?
Summary
UltraVNC revision 1211 has a heap buffer overflow vulnerability in VNC server code inside file transfer handler, which can potentially result code execution. This attack appears to be exploitable via network connectivity. This vulnerability has been fixed in revision 1212.
Severity ?
No CVSS data available.
CWE
- CWE-122 - Heap-based Buffer Overflow
Assigner
References
| URL | Tags | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Kaspersky Lab | UltraVNC |
Affected:
1.2.2.3
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T21:17:31.251Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://ics-cert.kaspersky.com/advisories/klcert-advisories/2019/03/01/klcert-19-018-ultravnc-heap-based-buffer-overflow/"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-927095.pdf"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.us-cert.gov/ics/advisories/icsa-20-161-06"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "UltraVNC",
"vendor": "Kaspersky Lab",
"versions": [
{
"status": "affected",
"version": "1.2.2.3"
}
]
}
],
"datePublic": "2019-03-01T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "UltraVNC revision 1211 has a heap buffer overflow vulnerability in VNC server code inside file transfer handler, which can potentially result code execution. This attack appears to be exploitable via network connectivity. This vulnerability has been fixed in revision 1212."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-122",
"description": "CWE-122: Heap-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-06-12T20:53:56",
"orgId": "e45d732a-8f6b-4b6b-be76-7420f6a2b988",
"shortName": "Kaspersky"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://ics-cert.kaspersky.com/advisories/klcert-advisories/2019/03/01/klcert-19-018-ultravnc-heap-based-buffer-overflow/"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-927095.pdf"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.us-cert.gov/ics/advisories/icsa-20-161-06"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "vulnerability@kaspersky.com",
"DATE_PUBLIC": "2019-03-01T00:00:00",
"ID": "CVE-2019-8271",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "UltraVNC",
"version": {
"version_data": [
{
"version_value": "1.2.2.3"
}
]
}
}
]
},
"vendor_name": "Kaspersky Lab"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "UltraVNC revision 1211 has a heap buffer overflow vulnerability in VNC server code inside file transfer handler, which can potentially result code execution. This attack appears to be exploitable via network connectivity. This vulnerability has been fixed in revision 1212."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-122: Heap-based Buffer Overflow"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://ics-cert.kaspersky.com/advisories/klcert-advisories/2019/03/01/klcert-19-018-ultravnc-heap-based-buffer-overflow/",
"refsource": "MISC",
"url": "https://ics-cert.kaspersky.com/advisories/klcert-advisories/2019/03/01/klcert-19-018-ultravnc-heap-based-buffer-overflow/"
},
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-927095.pdf",
"refsource": "CONFIRM",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-927095.pdf"
},
{
"name": "https://www.us-cert.gov/ics/advisories/icsa-20-161-06",
"refsource": "MISC",
"url": "https://www.us-cert.gov/ics/advisories/icsa-20-161-06"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "e45d732a-8f6b-4b6b-be76-7420f6a2b988",
"assignerShortName": "Kaspersky",
"cveId": "CVE-2019-8271",
"datePublished": "2019-03-09T00:00:00Z",
"dateReserved": "2019-02-12T00:00:00",
"dateUpdated": "2024-09-16T23:26:16.493Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2019-8269 (GCVE-0-2019-8269)
Vulnerability from nvd – Published: 2019-03-09 00:00 – Updated: 2024-09-17 00:30
VLAI?
Summary
UltraVNC revision 1206 has stack-based Buffer overflow vulnerability in VNC client code inside FileTransfer module, which leads to a denial of service (DoS) condition. This attack appear to be exploitable via network connectivity. This vulnerability has been fixed in revision 1207.
Severity ?
No CVSS data available.
CWE
- CWE-121 - Stack-based Buffer Overflow
Assigner
References
| URL | Tags | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Kaspersky Lab | UltraVNC |
Affected:
1.2.2.3
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T21:17:30.516Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://ics-cert.kaspersky.com/advisories/klcert-advisories/2019/03/01/klcert-19-016-ultravnc-stack-based-buffer-overflow/"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-927095.pdf"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.us-cert.gov/ics/advisories/icsa-20-161-06"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "UltraVNC",
"vendor": "Kaspersky Lab",
"versions": [
{
"status": "affected",
"version": "1.2.2.3"
}
]
}
],
"datePublic": "2019-03-01T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "UltraVNC revision 1206 has stack-based Buffer overflow vulnerability in VNC client code inside FileTransfer module, which leads to a denial of service (DoS) condition. This attack appear to be exploitable via network connectivity. This vulnerability has been fixed in revision 1207."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "CWE-121: Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-06-12T20:52:57",
"orgId": "e45d732a-8f6b-4b6b-be76-7420f6a2b988",
"shortName": "Kaspersky"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://ics-cert.kaspersky.com/advisories/klcert-advisories/2019/03/01/klcert-19-016-ultravnc-stack-based-buffer-overflow/"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-927095.pdf"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.us-cert.gov/ics/advisories/icsa-20-161-06"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "vulnerability@kaspersky.com",
"DATE_PUBLIC": "2019-03-01T00:00:00",
"ID": "CVE-2019-8269",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "UltraVNC",
"version": {
"version_data": [
{
"version_value": "1.2.2.3"
}
]
}
}
]
},
"vendor_name": "Kaspersky Lab"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "UltraVNC revision 1206 has stack-based Buffer overflow vulnerability in VNC client code inside FileTransfer module, which leads to a denial of service (DoS) condition. This attack appear to be exploitable via network connectivity. This vulnerability has been fixed in revision 1207."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-121: Stack-based Buffer Overflow"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://ics-cert.kaspersky.com/advisories/klcert-advisories/2019/03/01/klcert-19-016-ultravnc-stack-based-buffer-overflow/",
"refsource": "MISC",
"url": "https://ics-cert.kaspersky.com/advisories/klcert-advisories/2019/03/01/klcert-19-016-ultravnc-stack-based-buffer-overflow/"
},
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-927095.pdf",
"refsource": "CONFIRM",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-927095.pdf"
},
{
"name": "https://www.us-cert.gov/ics/advisories/icsa-20-161-06",
"refsource": "MISC",
"url": "https://www.us-cert.gov/ics/advisories/icsa-20-161-06"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "e45d732a-8f6b-4b6b-be76-7420f6a2b988",
"assignerShortName": "Kaspersky",
"cveId": "CVE-2019-8269",
"datePublished": "2019-03-09T00:00:00Z",
"dateReserved": "2019-02-12T00:00:00",
"dateUpdated": "2024-09-17T00:30:43.266Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2019-8268 (GCVE-0-2019-8268)
Vulnerability from nvd – Published: 2019-03-09 00:00 – Updated: 2024-09-17 01:16
VLAI?
Summary
UltraVNC revision 1206 has multiple off-by-one vulnerabilities in VNC client code connected with improper usage of ClientConnection::ReadString function, which can potentially result code execution. This attack appears to be exploitable via network connectivity. These vulnerabilities have been fixed in revision 1207.
Severity ?
No CVSS data available.
CWE
- CWE-193 - Off-by-one Error
Assigner
References
| URL | Tags | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Kaspersky Lab | UltraVNC |
Affected:
1.2.2.3
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T21:17:30.455Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://ics-cert.kaspersky.com/advisories/klcert-advisories/2019/03/01/klcert-19-015-ultravnc-off-by-one-error/"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-927095.pdf"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.us-cert.gov/ics/advisories/icsa-20-161-06"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "UltraVNC",
"vendor": "Kaspersky Lab",
"versions": [
{
"status": "affected",
"version": "1.2.2.3"
}
]
}
],
"datePublic": "2019-03-01T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "UltraVNC revision 1206 has multiple off-by-one vulnerabilities in VNC client code connected with improper usage of ClientConnection::ReadString function, which can potentially result code execution. This attack appears to be exploitable via network connectivity. These vulnerabilities have been fixed in revision 1207."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-193",
"description": "CWE-193: Off-by-one Error",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-06-12T20:52:16",
"orgId": "e45d732a-8f6b-4b6b-be76-7420f6a2b988",
"shortName": "Kaspersky"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://ics-cert.kaspersky.com/advisories/klcert-advisories/2019/03/01/klcert-19-015-ultravnc-off-by-one-error/"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-927095.pdf"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.us-cert.gov/ics/advisories/icsa-20-161-06"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "vulnerability@kaspersky.com",
"DATE_PUBLIC": "2019-03-01T00:00:00",
"ID": "CVE-2019-8268",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "UltraVNC",
"version": {
"version_data": [
{
"version_value": "1.2.2.3"
}
]
}
}
]
},
"vendor_name": "Kaspersky Lab"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "UltraVNC revision 1206 has multiple off-by-one vulnerabilities in VNC client code connected with improper usage of ClientConnection::ReadString function, which can potentially result code execution. This attack appears to be exploitable via network connectivity. These vulnerabilities have been fixed in revision 1207."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-193: Off-by-one Error"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://ics-cert.kaspersky.com/advisories/klcert-advisories/2019/03/01/klcert-19-015-ultravnc-off-by-one-error/",
"refsource": "MISC",
"url": "https://ics-cert.kaspersky.com/advisories/klcert-advisories/2019/03/01/klcert-19-015-ultravnc-off-by-one-error/"
},
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-927095.pdf",
"refsource": "CONFIRM",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-927095.pdf"
},
{
"name": "https://www.us-cert.gov/ics/advisories/icsa-20-161-06",
"refsource": "MISC",
"url": "https://www.us-cert.gov/ics/advisories/icsa-20-161-06"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "e45d732a-8f6b-4b6b-be76-7420f6a2b988",
"assignerShortName": "Kaspersky",
"cveId": "CVE-2019-8268",
"datePublished": "2019-03-09T00:00:00Z",
"dateReserved": "2019-02-12T00:00:00",
"dateUpdated": "2024-09-17T01:16:16.319Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2019-8263 (GCVE-0-2019-8263)
Vulnerability from nvd – Published: 2019-03-05 15:00 – Updated: 2024-09-16 23:56
VLAI?
Summary
UltraVNC revision 1205 has stack-based buffer overflow vulnerability in VNC client code inside ShowConnInfo routine, which leads to a denial of service (DoS) condition. This attack appear to be exploitable via network connectivity. User interaction is required to trigger this vulnerability. This vulnerability has been fixed in revision 1206.
Severity ?
No CVSS data available.
CWE
- CWE-121 - Stack-based Buffer Overflow
Assigner
References
| URL | Tags | ||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||||||||||||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Kaspersky Lab | UltraVNC |
Affected:
1.2.2.3
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T21:17:30.560Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://ics-cert.kaspersky.com/advisories/klcert-advisories/2019/03/01/klcert-19-009-ultravnc-access-of-memory-location-after-end-of-buffer/"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://ics-cert.kaspersky.com/advisories/klcert-advisories/2019/03/01/klcert-19-010-ultravnc-stack-based-buffer-overflow/"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-927095.pdf"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.us-cert.gov/ics/advisories/icsa-20-161-06"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-940818.pdf"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-11"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "UltraVNC",
"vendor": "Kaspersky Lab",
"versions": [
{
"status": "affected",
"version": "1.2.2.3"
}
]
}
],
"datePublic": "2019-03-01T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "UltraVNC revision 1205 has stack-based buffer overflow vulnerability in VNC client code inside ShowConnInfo routine, which leads to a denial of service (DoS) condition. This attack appear to be exploitable via network connectivity. User interaction is required to trigger this vulnerability. This vulnerability has been fixed in revision 1206."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "CWE-121: Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-06-28T11:53:57",
"orgId": "e45d732a-8f6b-4b6b-be76-7420f6a2b988",
"shortName": "Kaspersky"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://ics-cert.kaspersky.com/advisories/klcert-advisories/2019/03/01/klcert-19-009-ultravnc-access-of-memory-location-after-end-of-buffer/"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://ics-cert.kaspersky.com/advisories/klcert-advisories/2019/03/01/klcert-19-010-ultravnc-stack-based-buffer-overflow/"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-927095.pdf"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.us-cert.gov/ics/advisories/icsa-20-161-06"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-940818.pdf"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-11"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "vulnerability@kaspersky.com",
"DATE_PUBLIC": "2019-03-01T00:00:00",
"ID": "CVE-2019-8263",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "UltraVNC",
"version": {
"version_data": [
{
"version_value": "1.2.2.3"
}
]
}
}
]
},
"vendor_name": "Kaspersky Lab"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "UltraVNC revision 1205 has stack-based buffer overflow vulnerability in VNC client code inside ShowConnInfo routine, which leads to a denial of service (DoS) condition. This attack appear to be exploitable via network connectivity. User interaction is required to trigger this vulnerability. This vulnerability has been fixed in revision 1206."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-121: Stack-based Buffer Overflow"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://ics-cert.kaspersky.com/advisories/klcert-advisories/2019/03/01/klcert-19-009-ultravnc-access-of-memory-location-after-end-of-buffer/",
"refsource": "MISC",
"url": "https://ics-cert.kaspersky.com/advisories/klcert-advisories/2019/03/01/klcert-19-009-ultravnc-access-of-memory-location-after-end-of-buffer/"
},
{
"name": "https://ics-cert.kaspersky.com/advisories/klcert-advisories/2019/03/01/klcert-19-010-ultravnc-stack-based-buffer-overflow/",
"refsource": "MISC",
"url": "https://ics-cert.kaspersky.com/advisories/klcert-advisories/2019/03/01/klcert-19-010-ultravnc-stack-based-buffer-overflow/"
},
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-927095.pdf",
"refsource": "CONFIRM",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-927095.pdf"
},
{
"name": "https://www.us-cert.gov/ics/advisories/icsa-20-161-06",
"refsource": "MISC",
"url": "https://www.us-cert.gov/ics/advisories/icsa-20-161-06"
},
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-940818.pdf",
"refsource": "CONFIRM",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-940818.pdf"
},
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf",
"refsource": "CONFIRM",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf"
},
{
"name": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-11",
"refsource": "MISC",
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-11"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "e45d732a-8f6b-4b6b-be76-7420f6a2b988",
"assignerShortName": "Kaspersky",
"cveId": "CVE-2019-8263",
"datePublished": "2019-03-05T15:00:00Z",
"dateReserved": "2019-02-12T00:00:00",
"dateUpdated": "2024-09-16T23:56:07.697Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2019-8262 (GCVE-0-2019-8262)
Vulnerability from nvd – Published: 2019-03-05 15:00 – Updated: 2024-09-16 16:49
VLAI?
Summary
UltraVNC revision 1203 has multiple heap buffer overflow vulnerabilities in VNC client code inside Ultra decoder, which results in code execution. This attack appears to be exploitable via network connectivity. These vulnerabilities have been fixed in revision 1204.
Severity ?
No CVSS data available.
CWE
- CWE-122 - Heap-based Buffer Overflow
Assigner
References
| URL | Tags | |||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T21:17:30.593Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://ics-cert.kaspersky.com/advisories/klcert-advisories/2019/03/01/klcert-19-008-ultravnc-heap-based-buffer-overflow/"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-927095.pdf"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.us-cert.gov/ics/advisories/icsa-20-161-06"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-940818.pdf"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-11"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "UltraVNC",
"vendor": "UltraVNC",
"versions": [
{
"status": "affected",
"version": "1.2.2.3"
}
]
}
],
"datePublic": "2019-03-01T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "UltraVNC revision 1203 has multiple heap buffer overflow vulnerabilities in VNC client code inside Ultra decoder, which results in code execution. This attack appears to be exploitable via network connectivity. These vulnerabilities have been fixed in revision 1204."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-122",
"description": "CWE-122: Heap-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-06-28T11:52:18",
"orgId": "e45d732a-8f6b-4b6b-be76-7420f6a2b988",
"shortName": "Kaspersky"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://ics-cert.kaspersky.com/advisories/klcert-advisories/2019/03/01/klcert-19-008-ultravnc-heap-based-buffer-overflow/"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-927095.pdf"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.us-cert.gov/ics/advisories/icsa-20-161-06"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-940818.pdf"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-11"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "vulnerability@kaspersky.com",
"DATE_PUBLIC": "2019-03-01T00:00:00",
"ID": "CVE-2019-8262",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "UltraVNC",
"version": {
"version_data": [
{
"version_value": "1.2.2.3"
}
]
}
}
]
},
"vendor_name": "UltraVNC"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "UltraVNC revision 1203 has multiple heap buffer overflow vulnerabilities in VNC client code inside Ultra decoder, which results in code execution. This attack appears to be exploitable via network connectivity. These vulnerabilities have been fixed in revision 1204."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-122: Heap-based Buffer Overflow"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://ics-cert.kaspersky.com/advisories/klcert-advisories/2019/03/01/klcert-19-008-ultravnc-heap-based-buffer-overflow/",
"refsource": "MISC",
"url": "https://ics-cert.kaspersky.com/advisories/klcert-advisories/2019/03/01/klcert-19-008-ultravnc-heap-based-buffer-overflow/"
},
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-927095.pdf",
"refsource": "CONFIRM",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-927095.pdf"
},
{
"name": "https://www.us-cert.gov/ics/advisories/icsa-20-161-06",
"refsource": "MISC",
"url": "https://www.us-cert.gov/ics/advisories/icsa-20-161-06"
},
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-940818.pdf",
"refsource": "CONFIRM",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-940818.pdf"
},
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf",
"refsource": "CONFIRM",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf"
},
{
"name": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-11",
"refsource": "MISC",
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-11"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "e45d732a-8f6b-4b6b-be76-7420f6a2b988",
"assignerShortName": "Kaspersky",
"cveId": "CVE-2019-8262",
"datePublished": "2019-03-05T15:00:00Z",
"dateReserved": "2019-02-12T00:00:00",
"dateUpdated": "2024-09-16T16:49:03.600Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2019-8259 (GCVE-0-2019-8259)
Vulnerability from nvd – Published: 2019-03-05 15:00 – Updated: 2024-09-16 20:59
VLAI?
Summary
UltraVNC revision 1198 contains multiple memory leaks (CWE-655) in VNC client code, which allow an attacker to read stack memory and can be abused for information disclosure. Combined with another vulnerability, it can be used to leak stack memory and bypass ASLR. This attack appears to be exploitable via network connectivity. These vulnerabilities have been fixed in revision 1199.
Severity ?
No CVSS data available.
CWE
- CWE-665 - Improper Initialization
Assigner
References
| URL | Tags | |||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T21:17:30.187Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://ics-cert.kaspersky.com/advisories/klcert-advisories/2019/03/01/klcert-19-005-ultravnc-memory-leak/"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-927095.pdf"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.us-cert.gov/ics/advisories/icsa-20-161-06"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-940818.pdf"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-11"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "UltraVNC",
"vendor": "UltraVNC",
"versions": [
{
"status": "affected",
"version": "1.2.2.3"
}
]
}
],
"datePublic": "2019-03-01T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "UltraVNC revision 1198 contains multiple memory leaks (CWE-655) in VNC client code, which allow an attacker to read stack memory and can be abused for information disclosure. Combined with another vulnerability, it can be used to leak stack memory and bypass ASLR. This attack appears to be exploitable via network connectivity. These vulnerabilities have been fixed in revision 1199."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-665",
"description": "CWE-665: Improper Initialization",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-06-28T12:10:55",
"orgId": "e45d732a-8f6b-4b6b-be76-7420f6a2b988",
"shortName": "Kaspersky"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://ics-cert.kaspersky.com/advisories/klcert-advisories/2019/03/01/klcert-19-005-ultravnc-memory-leak/"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-927095.pdf"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.us-cert.gov/ics/advisories/icsa-20-161-06"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-940818.pdf"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-11"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "vulnerability@kaspersky.com",
"DATE_PUBLIC": "2019-03-01T00:00:00",
"ID": "CVE-2019-8259",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "UltraVNC",
"version": {
"version_data": [
{
"version_value": "1.2.2.3"
}
]
}
}
]
},
"vendor_name": "UltraVNC"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "UltraVNC revision 1198 contains multiple memory leaks (CWE-655) in VNC client code, which allow an attacker to read stack memory and can be abused for information disclosure. Combined with another vulnerability, it can be used to leak stack memory and bypass ASLR. This attack appears to be exploitable via network connectivity. These vulnerabilities have been fixed in revision 1199."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-665: Improper Initialization"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://ics-cert.kaspersky.com/advisories/klcert-advisories/2019/03/01/klcert-19-005-ultravnc-memory-leak/",
"refsource": "MISC",
"url": "https://ics-cert.kaspersky.com/advisories/klcert-advisories/2019/03/01/klcert-19-005-ultravnc-memory-leak/"
},
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-927095.pdf",
"refsource": "CONFIRM",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-927095.pdf"
},
{
"name": "https://www.us-cert.gov/ics/advisories/icsa-20-161-06",
"refsource": "MISC",
"url": "https://www.us-cert.gov/ics/advisories/icsa-20-161-06"
},
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-940818.pdf",
"refsource": "CONFIRM",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-940818.pdf"
},
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf",
"refsource": "CONFIRM",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf"
},
{
"name": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-11",
"refsource": "MISC",
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-11"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "e45d732a-8f6b-4b6b-be76-7420f6a2b988",
"assignerShortName": "Kaspersky",
"cveId": "CVE-2019-8259",
"datePublished": "2019-03-05T15:00:00Z",
"dateReserved": "2019-02-12T00:00:00",
"dateUpdated": "2024-09-16T20:59:11.748Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2019-8258 (GCVE-0-2019-8258)
Vulnerability from nvd – Published: 2019-03-05 15:00 – Updated: 2024-09-16 19:15
VLAI?
Summary
UltraVNC revision 1198 has a heap buffer overflow vulnerability in VNC client code which results code execution. This attack appears to be exploitable via network connectivity. This vulnerability has been fixed in revision 1199.
Severity ?
No CVSS data available.
CWE
- CWE-122 - Heap-based Buffer Overflow
Assigner
References
| URL | Tags | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T21:17:30.160Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://ics-cert.kaspersky.com/advisories/klcert-advisories/2019/03/01/klcert-19-004-ultravnc-heap-based-buffer-overflow/"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-927095.pdf"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.us-cert.gov/ics/advisories/icsa-20-161-06"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "UltraVNC",
"vendor": "UltraVNC",
"versions": [
{
"status": "affected",
"version": "1.2.2.3"
}
]
}
],
"datePublic": "2019-03-01T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "UltraVNC revision 1198 has a heap buffer overflow vulnerability in VNC client code which results code execution. This attack appears to be exploitable via network connectivity. This vulnerability has been fixed in revision 1199."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-122",
"description": "CWE-122: Heap-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-06-10T21:33:11",
"orgId": "e45d732a-8f6b-4b6b-be76-7420f6a2b988",
"shortName": "Kaspersky"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://ics-cert.kaspersky.com/advisories/klcert-advisories/2019/03/01/klcert-19-004-ultravnc-heap-based-buffer-overflow/"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-927095.pdf"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.us-cert.gov/ics/advisories/icsa-20-161-06"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "vulnerability@kaspersky.com",
"DATE_PUBLIC": "2019-03-01T00:00:00",
"ID": "CVE-2019-8258",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "UltraVNC",
"version": {
"version_data": [
{
"version_value": "1.2.2.3"
}
]
}
}
]
},
"vendor_name": "UltraVNC"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "UltraVNC revision 1198 has a heap buffer overflow vulnerability in VNC client code which results code execution. This attack appears to be exploitable via network connectivity. This vulnerability has been fixed in revision 1199."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-122: Heap-based Buffer Overflow"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://ics-cert.kaspersky.com/advisories/klcert-advisories/2019/03/01/klcert-19-004-ultravnc-heap-based-buffer-overflow/",
"refsource": "MISC",
"url": "https://ics-cert.kaspersky.com/advisories/klcert-advisories/2019/03/01/klcert-19-004-ultravnc-heap-based-buffer-overflow/"
},
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-927095.pdf",
"refsource": "CONFIRM",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-927095.pdf"
},
{
"name": "https://www.us-cert.gov/ics/advisories/icsa-20-161-06",
"refsource": "MISC",
"url": "https://www.us-cert.gov/ics/advisories/icsa-20-161-06"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "e45d732a-8f6b-4b6b-be76-7420f6a2b988",
"assignerShortName": "Kaspersky",
"cveId": "CVE-2019-8258",
"datePublished": "2019-03-05T15:00:00Z",
"dateReserved": "2019-02-12T00:00:00",
"dateUpdated": "2024-09-16T19:15:25.845Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}