Search
Find a vulnerability
Search criteria
6 vulnerabilities found for sinamics_startdrive by siemens
CVE-2023-32736 (GCVE-0-2023-32736)
Vulnerability from nvd – Published: 2024-11-12 12:49 – Updated: 2025-01-14 10:27
VLAI
EPSS
VEX
Summary
A vulnerability has been identified in SIMATIC S7-PLCSIM V16 (All versions), SIMATIC S7-PLCSIM V17 (All versions), SIMATIC STEP 7 Safety V16 (All versions), SIMATIC STEP 7 Safety V17 (All versions < V17 Update 8), SIMATIC STEP 7 Safety V18 (All versions < V18 Update 5), SIMATIC STEP 7 V16 (All versions), SIMATIC STEP 7 V17 (All versions < V17 Update 8), SIMATIC STEP 7 V18 (All versions < V18 Update 5), SIMATIC WinCC Unified V16 (All versions), SIMATIC WinCC Unified V17 (All versions < V17 Update 8), SIMATIC WinCC Unified V18 (All versions < V18 SP5), SIMATIC WinCC V16 (All versions), SIMATIC WinCC V17 (All versions < V17 Update 8), SIMATIC WinCC V18 (All versions < V18 SP5), SIMOCODE ES V16 (All versions), SIMOCODE ES V17 (All versions < V17 Update 8), SIMOCODE ES V18 (All versions), SIMOTION SCOUT TIA V5.4 SP1 (All versions), SIMOTION SCOUT TIA V5.4 SP3 (All versions), SIMOTION SCOUT TIA V5.5 SP1 (All versions), SINAMICS Startdrive V16 (All versions), SINAMICS Startdrive V17 (All versions), SINAMICS Startdrive V18 (All versions), SIRIUS Safety ES V17 (TIA Portal) (All versions < V17 Update 8), SIRIUS Safety ES V18 (TIA Portal) (All versions), SIRIUS Soft Starter ES V17 (TIA Portal) (All versions < V17 Update 8), SIRIUS Soft Starter ES V18 (TIA Portal) (All versions), TIA Portal Cloud V16 (All versions), TIA Portal Cloud V17 (All versions < V4.6.0.1), TIA Portal Cloud V18 (All versions < V4.6.1.0). Affected products do not properly sanitize user-controllable input when parsing user settings. This could allow an attacker to cause a type confusion and execute arbitrary code within the affected application.
Severity
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2024-12-02 19:49 UTC
CWE
- CWE-502 - Deserialization of Untrusted Data
Assigner
References
1 reference
Impacted products
39 products
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens | SIMATIC S7-PLCSIM V16 |
Affected:
0 , < *
(custom)
|
|
| Siemens | SIMATIC S7-PLCSIM V17 |
Affected:
0 , < *
(custom)
|
|
| Siemens | SIMATIC STEP 7 Safety V16 |
Affected:
0 , < *
(custom)
|
|
| Siemens | SIMATIC STEP 7 Safety V17 |
Affected:
0 , < V17 Update 8
(custom)
|
|
| Siemens | SIMATIC STEP 7 Safety V18 |
Affected:
0 , < V18 Update 5
(custom)
|
|
| Siemens | SIMATIC STEP 7 V16 |
Affected:
0 , < *
(custom)
|
|
| Siemens | SIMATIC STEP 7 V17 |
Affected:
0 , < V17 Update 8
(custom)
|
|
| Siemens | SIMATIC STEP 7 V18 |
Affected:
0 , < V18 Update 5
(custom)
|
|
| Siemens | SIMATIC WinCC Unified V16 |
Affected:
0 , < *
(custom)
|
|
| Siemens | SIMATIC WinCC Unified V17 |
Affected:
0 , < V17 Update 8
(custom)
|
|
| Siemens | SIMATIC WinCC Unified V18 |
Affected:
0 , < V18 SP5
(custom)
|
|
| Siemens | SIMATIC WinCC V16 |
Affected:
0 , < *
(custom)
|
|
| Siemens | SIMATIC WinCC V17 |
Affected:
0 , < V17 Update 8
(custom)
|
|
| Siemens | SIMATIC WinCC V18 |
Affected:
0 , < V18 SP5
(custom)
|
|
| Siemens | SIMOCODE ES V16 |
Affected:
0 , < *
(custom)
|
|
| Siemens | SIMOCODE ES V17 |
Affected:
0 , < V17 Update 8
(custom)
|
|
| Siemens | SIMOCODE ES V18 |
Affected:
0 , < *
(custom)
|
|
| Siemens | SIMOTION SCOUT TIA V5.4 SP1 |
Affected:
0 , < *
(custom)
|
|
| Siemens | SIMOTION SCOUT TIA V5.4 SP3 |
Affected:
0 , < *
(custom)
|
|
| Siemens | SIMOTION SCOUT TIA V5.5 SP1 |
Affected:
0 , < *
(custom)
|
|
| Siemens | SINAMICS Startdrive V16 |
Affected:
0 , < *
(custom)
|
|
| Siemens | SINAMICS Startdrive V17 |
Affected:
0 , < *
(custom)
|
|
| Siemens | SINAMICS Startdrive V18 |
Affected:
0 , < *
(custom)
|
|
| Siemens | SIRIUS Safety ES V17 (TIA Portal) |
Affected:
0 , < V17 Update 8
(custom)
|
|
| Siemens | SIRIUS Safety ES V18 (TIA Portal) |
Affected:
0 , < *
(custom)
|
|
| Siemens | SIRIUS Soft Starter ES V17 (TIA Portal) |
Affected:
0 , < V17 Update 8
(custom)
|
|
| Siemens | SIRIUS Soft Starter ES V18 (TIA Portal) |
Affected:
0 , < *
(custom)
|
|
| Siemens | TIA Portal Cloud V16 |
Affected:
0 , < *
(custom)
|
|
| Siemens | TIA Portal Cloud V17 |
Affected:
0 , < V4.6.0.1
(custom)
|
|
| Siemens | TIA Portal Cloud V18 |
Affected:
0 , < V4.6.1.0
(custom)
|
|
| siemens | simatic_step_7 |
Affected:
16 , < 17
(custom)
Affected: 17 , < 17_update8 (custom) Affected: 18 , < 18_update5 (custom) cpe:2.3:h:siemens:simatic_step_7:-:*:*:*:*:*:*:* |
|
| siemens | simatic_s7-plcsim |
Affected:
16 , < 17
(custom)
Affected: 17 , < * (custom) cpe:2.3:a:siemens:simatic_s7-plcsim:-:*:*:*:*:*:*:* |
|
| siemens | simatic_wincc |
Affected:
16 , < 17
(custom)
Affected: 17 , < 17_update8 (custom) Affected: 18 , < 18_update5 (custom) cpe:2.3:a:siemens:simatic_wincc:-:*:*:*:*:*:*:* |
|
| siemens | simatic_wincc_unified |
Affected:
16 , < 17
(custom)
Affected: 17 , < 17_update8 (custom) Affected: 18 , < 18_update5 (custom) cpe:2.3:a:siemens:simatic_wincc_unified:*:*:*:*:*:*:*:* |
|
| siemens | simocode_es |
Affected:
16 , < 17
(custom)
Affected: 17 , < 17_update8 (custom) Affected: 18 , < * (custom) cpe:2.3:a:siemens:simocode_es:-:*:*:*:*:*:*:* |
|
| siemens | simotion_scout_tia |
Affected:
v5.4sp1 , < *
(custom)
Affected: v5.4sp3 , < * (custom) Affected: v5.5sp1 , < * (custom) cpe:2.3:a:siemens:simotion_scout_tia:v5.4sp1:*:*:*:*:*:*:* cpe:2.3:a:siemens:simotion_scout_tia:v5.4sp3:*:*:*:*:*:*:* cpe:2.3:a:siemens:simotion_scout_tia:v5.5sp1:*:*:*:*:*:*:* |
|
| siemens | sinamics_startdrive |
Affected:
16 , < 17
(custom)
Affected: 17 , < 18 (custom) Affected: 18 , < * (custom) cpe:2.3:a:siemens:sinamics_startdrive:-:*:*:*:*:*:*:* |
|
| siemens | sirius_safety_es |
Affected:
0 , < 17_update8
(custom)
Affected: 18 , < * (custom) cpe:2.3:a:siemens:sirius_safety_es:*:*:*:*:*:*:*:* |
|
| siemens | tia_portal_cloud |
Affected:
16 , < *
(custom)
Affected: 17 , < * (custom) Affected: 18 , < * (custom) cpe:2.3:a:siemens:tia_portal_cloud:*:*:*:*:*:*:*:* |
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:h:siemens:simatic_step_7:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simatic_step_7",
"vendor": "siemens",
"versions": [
{
"lessThan": "17",
"status": "affected",
"version": "16",
"versionType": "custom"
},
{
"lessThan": "17_update8",
"status": "affected",
"version": "17",
"versionType": "custom"
},
{
"lessThan": "18_update5",
"status": "affected",
"version": "18",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:simatic_step_7:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simatic_step_7",
"vendor": "siemens",
"versions": [
{
"lessThan": "17",
"status": "affected",
"version": "16",
"versionType": "custom"
},
{
"lessThan": "17_update8",
"status": "affected",
"version": "17",
"versionType": "custom"
},
{
"lessThan": "18_update5",
"status": "affected",
"version": "18",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:siemens:simatic_s7-plcsim:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simatic_s7-plcsim",
"vendor": "siemens",
"versions": [
{
"lessThan": "17",
"status": "affected",
"version": "16",
"versionType": "custom"
},
{
"lessThan": "*",
"status": "affected",
"version": "17",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:siemens:simatic_wincc:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simatic_wincc",
"vendor": "siemens",
"versions": [
{
"lessThan": "17",
"status": "affected",
"version": "16",
"versionType": "custom"
},
{
"lessThan": "17_update8",
"status": "affected",
"version": "17",
"versionType": "custom"
},
{
"lessThan": "18_update5",
"status": "affected",
"version": "18",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:siemens:simatic_wincc_unified:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simatic_wincc_unified",
"vendor": "siemens",
"versions": [
{
"lessThan": "17",
"status": "affected",
"version": "16",
"versionType": "custom"
},
{
"lessThan": "17_update8",
"status": "affected",
"version": "17",
"versionType": "custom"
},
{
"lessThan": "18_update5",
"status": "affected",
"version": "18",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:siemens:simocode_es:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simocode_es",
"vendor": "siemens",
"versions": [
{
"lessThan": "17",
"status": "affected",
"version": "16",
"versionType": "custom"
},
{
"lessThan": "17_update8",
"status": "affected",
"version": "17",
"versionType": "custom"
},
{
"lessThan": "*",
"status": "affected",
"version": "18",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:siemens:simotion_scout_tia:v5.4sp1:*:*:*:*:*:*:*",
"cpe:2.3:a:siemens:simotion_scout_tia:v5.4sp3:*:*:*:*:*:*:*",
"cpe:2.3:a:siemens:simotion_scout_tia:v5.5sp1:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simotion_scout_tia",
"vendor": "siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "v5.4sp1",
"versionType": "custom"
},
{
"lessThan": "*",
"status": "affected",
"version": "v5.4sp3",
"versionType": "custom"
},
{
"lessThan": "*",
"status": "affected",
"version": "v5.5sp1",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:siemens:sinamics_startdrive:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "sinamics_startdrive",
"vendor": "siemens",
"versions": [
{
"lessThan": "17",
"status": "affected",
"version": "16",
"versionType": "custom"
},
{
"lessThan": "18",
"status": "affected",
"version": "17",
"versionType": "custom"
},
{
"lessThan": "*",
"status": "affected",
"version": "18",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:siemens:sirius_safety_es:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "sirius_safety_es",
"vendor": "siemens",
"versions": [
{
"lessThan": "17_update8",
"status": "affected",
"version": "0",
"versionType": "custom"
},
{
"lessThan": "*",
"status": "affected",
"version": "18",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:siemens:tia_portal_cloud:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "tia_portal_cloud",
"vendor": "siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "16",
"versionType": "custom"
},
{
"lessThan": "*",
"status": "affected",
"version": "17",
"versionType": "custom"
},
{
"lessThan": "*",
"status": "affected",
"version": "18",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-32736",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-12-02T19:49:50.974471Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-12-02T20:16:52.424Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-PLCSIM V16",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-PLCSIM V17",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC STEP 7 Safety V16",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC STEP 7 Safety V17",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V17 Update 8",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC STEP 7 Safety V18",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V18 Update 5",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC STEP 7 V16",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC STEP 7 V17",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V17 Update 8",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC STEP 7 V18",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V18 Update 5",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC WinCC Unified V16",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC WinCC Unified V17",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V17 Update 8",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC WinCC Unified V18",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V18 SP5",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC WinCC V16",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC WinCC V17",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V17 Update 8",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC WinCC V18",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V18 SP5",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMOCODE ES V16",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMOCODE ES V17",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V17 Update 8",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMOCODE ES V18",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMOTION SCOUT TIA V5.4 SP1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMOTION SCOUT TIA V5.4 SP3",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMOTION SCOUT TIA V5.5 SP1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINAMICS Startdrive V16",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINAMICS Startdrive V17",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINAMICS Startdrive V18",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIRIUS Safety ES V17 (TIA Portal)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V17 Update 8",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIRIUS Safety ES V18 (TIA Portal)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIRIUS Soft Starter ES V17 (TIA Portal)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V17 Update 8",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIRIUS Soft Starter ES V18 (TIA Portal)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "TIA Portal Cloud V16",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "TIA Portal Cloud V17",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6.0.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "TIA Portal Cloud V18",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6.1.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in SIMATIC S7-PLCSIM V16 (All versions), SIMATIC S7-PLCSIM V17 (All versions), SIMATIC STEP 7 Safety V16 (All versions), SIMATIC STEP 7 Safety V17 (All versions \u003c V17 Update 8), SIMATIC STEP 7 Safety V18 (All versions \u003c V18 Update 5), SIMATIC STEP 7 V16 (All versions), SIMATIC STEP 7 V17 (All versions \u003c V17 Update 8), SIMATIC STEP 7 V18 (All versions \u003c V18 Update 5), SIMATIC WinCC Unified V16 (All versions), SIMATIC WinCC Unified V17 (All versions \u003c V17 Update 8), SIMATIC WinCC Unified V18 (All versions \u003c V18 SP5), SIMATIC WinCC V16 (All versions), SIMATIC WinCC V17 (All versions \u003c V17 Update 8), SIMATIC WinCC V18 (All versions \u003c V18 SP5), SIMOCODE ES V16 (All versions), SIMOCODE ES V17 (All versions \u003c V17 Update 8), SIMOCODE ES V18 (All versions), SIMOTION SCOUT TIA V5.4 SP1 (All versions), SIMOTION SCOUT TIA V5.4 SP3 (All versions), SIMOTION SCOUT TIA V5.5 SP1 (All versions), SINAMICS Startdrive V16 (All versions), SINAMICS Startdrive V17 (All versions), SINAMICS Startdrive V18 (All versions), SIRIUS Safety ES V17 (TIA Portal) (All versions \u003c V17 Update 8), SIRIUS Safety ES V18 (TIA Portal) (All versions), SIRIUS Soft Starter ES V17 (TIA Portal) (All versions \u003c V17 Update 8), SIRIUS Soft Starter ES V18 (TIA Portal) (All versions), TIA Portal Cloud V16 (All versions), TIA Portal Cloud V17 (All versions \u003c V4.6.0.1), TIA Portal Cloud V18 (All versions \u003c V4.6.1.0). Affected products do not properly sanitize user-controllable input when parsing user settings. This could allow an attacker to cause a type confusion and execute arbitrary code within the affected application."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 7.3,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
}
},
{
"cvssV4_0": {
"baseScore": 7,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-502",
"description": "CWE-502: Deserialization of Untrusted Data",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-01-14T10:27:17.694Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-871035.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2023-32736",
"datePublished": "2024-11-12T12:49:22.651Z",
"dateReserved": "2023-05-12T13:16:47.721Z",
"dateUpdated": "2025-01-14T10:27:17.694Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-32735 (GCVE-0-2023-32735)
Vulnerability from nvd – Published: 2024-07-09 12:04 – Updated: 2025-08-27 20:32
VLAI
EPSS
VEX
Summary
A vulnerability has been identified in SIMATIC STEP 7 Safety V16 (All versions < V16 Update 7), SIMATIC STEP 7 Safety V17 (All versions < V17 Update 7), SIMATIC STEP 7 Safety V18 (All versions < V18 Update 2), SIMATIC STEP 7 V16 (All versions < V16 Update 7), SIMATIC STEP 7 V17 (All versions < V17 Update 7), SIMATIC STEP 7 V18 (All versions < V18 Update 2), SIMATIC WinCC Unified V16 (All versions < V16 Update 7), SIMATIC WinCC Unified V17 (All versions < V17 Update 7), SIMATIC WinCC Unified V18 (All versions < V18 Update 2), SIMATIC WinCC V16 (All versions < V16.7), SIMATIC WinCC V17 (All versions < V17.7), SIMATIC WinCC V18 (All versions < V18 Update 2), SIMOCODE ES V16 (All versions < V16 Update 7), SIMOCODE ES V17 (All versions < V17 Update 7), SIMOCODE ES V18 (All versions < V18 Update 2), SIMOTION SCOUT TIA V5.4 SP1 (All versions), SIMOTION SCOUT TIA V5.4 SP3 (All versions), SIMOTION SCOUT TIA V5.5 SP1 (All versions), SINAMICS Startdrive V16 (All versions), SINAMICS Startdrive V17 (All versions), SINAMICS Startdrive V18 (All versions), SIRIUS Safety ES V17 (All versions < V17 Update 7), SIRIUS Safety ES V18 (All versions < V18 Update 2), SIRIUS Soft Starter ES V17 (All versions < V17 Update 7), SIRIUS Soft Starter ES V18 (All versions < V18 Update 2), Soft Starter ES V16 (All versions < V16 Update 7), TIA Portal Cloud V3.0 (All versions < V18 Update 2). Affected applications do not properly restrict the .NET BinaryFormatter when deserializing hardware configuration profiles. This could allow an attacker to cause a type confusion and execute arbitrary code within the affected application.
This is the same issue that exists for .NET BinaryFormatter https://docs.microsoft.com/en-us/visualstudio/code-quality/ca2300.
Severity
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2024-07-09 19:09 UTC
CWE
- CWE-502 - Deserialization of Untrusted Data
Assigner
References
1 reference
Impacted products
41 products
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens | SIMATIC STEP 7 Safety V16 |
Affected:
0 , < V16 Update 7
(custom)
|
|
| Siemens | SIMATIC STEP 7 Safety V17 |
Affected:
0 , < V17 Update 7
(custom)
|
|
| Siemens | SIMATIC STEP 7 Safety V18 |
Affected:
0 , < V18 Update 2
(custom)
|
|
| Siemens | SIMATIC STEP 7 V16 |
Affected:
0 , < V16 Update 7
(custom)
|
|
| Siemens | SIMATIC STEP 7 V17 |
Affected:
0 , < V17 Update 7
(custom)
|
|
| Siemens | SIMATIC STEP 7 V18 |
Affected:
0 , < V18 Update 2
(custom)
|
|
| Siemens | SIMATIC WinCC Unified V16 |
Affected:
0 , < V16 Update 7
(custom)
|
|
| Siemens | SIMATIC WinCC Unified V17 |
Affected:
0 , < V17 Update 7
(custom)
|
|
| Siemens | SIMATIC WinCC Unified V18 |
Affected:
0 , < V18 Update 2
(custom)
|
|
| Siemens | SIMATIC WinCC V16 |
Affected:
0 , < V16.7
(custom)
|
|
| Siemens | SIMATIC WinCC V17 |
Affected:
0 , < V17.7
(custom)
|
|
| Siemens | SIMATIC WinCC V18 |
Affected:
0 , < V18 Update 2
(custom)
|
|
| Siemens | SIMOCODE ES V16 |
Affected:
0 , < V16 Update 7
(custom)
|
|
| Siemens | SIMOCODE ES V17 |
Affected:
0 , < V17 Update 7
(custom)
|
|
| Siemens | SIMOCODE ES V18 |
Affected:
0 , < V18 Update 2
(custom)
|
|
| Siemens | SIMOTION SCOUT TIA V5.4 SP1 |
Affected:
0 , < *
(custom)
|
|
| Siemens | SIMOTION SCOUT TIA V5.4 SP3 |
Affected:
0 , < *
(custom)
|
|
| Siemens | SIMOTION SCOUT TIA V5.5 SP1 |
Affected:
0 , < *
(custom)
|
|
| Siemens | SINAMICS Startdrive V16 |
Affected:
0 , < *
(custom)
|
|
| Siemens | SINAMICS Startdrive V17 |
Affected:
0 , < *
(custom)
|
|
| Siemens | SINAMICS Startdrive V18 |
Affected:
0 , < *
(custom)
|
|
| Siemens | SIRIUS Safety ES V17 |
Affected:
0 , < V17 Update 7
(custom)
|
|
| Siemens | SIRIUS Safety ES V18 |
Affected:
0 , < V18 Update 2
(custom)
|
|
| Siemens | SIRIUS Soft Starter ES V17 |
Affected:
0 , < V17 Update 7
(custom)
|
|
| Siemens | SIRIUS Soft Starter ES V18 |
Affected:
0 , < V18 Update 2
(custom)
|
|
| Siemens | Soft Starter ES V16 |
Affected:
0 , < V16 Update 7
(custom)
|
|
| Siemens | TIA Portal Cloud V3.0 |
Affected:
0 , < V18 Update 2
(custom)
|
|
| siemens | simatic_step_7_safety |
Affected:
0 , < v16update7
(custom)
Affected: 0 , < v17update7 (custom) Affected: 0 , < v18update2 (custom) cpe:2.3:a:siemens:simatic_step_7_safety:*:*:*:*:*:*:*:* |
|
| siemens | simatic_step_7 |
Affected:
0 , < v16update7
(custom)
Affected: 0 , < v17update7 (custom) Affected: 0 , < v18update2 (custom) cpe:2.3:a:siemens:simatic_step_7:*:*:*:*:*:*:*:* |
|
| siemens | simatic_wincc_unified |
Affected:
0 , < v16update7
(custom)
Affected: 0 , < v17update7 (custom) Affected: 0 , < v18update2 (custom) cpe:2.3:a:siemens:simatic_wincc_unified:*:*:*:*:*:*:*:* |
|
| siemens | simatic_wincc |
Affected:
0 , < v17.7
(custom)
Affected: 0 , < v18update2 (custom) cpe:2.3:a:siemens:simatic_wincc:*:*:*:*:*:*:*:* |
|
| siemens | simocode_es |
Affected:
0 , < v16update7
(custom)
Affected: 0 , < v17update7 (custom) Affected: 0 , < v18update2 (custom) cpe:2.3:a:siemens:simocode_es:*:*:*:*:*:*:*:* |
|
| siemens | simotion_scout_tia |
Affected:
v5.4sp1
cpe:2.3:a:siemens:simotion_scout_tia:v5.4sp1:*:*:*:*:*:*:* |
|
| siemens | simotion_scout_tia |
Affected:
v5.4sp3
cpe:2.3:a:siemens:simotion_scout_tia:v5.4sp3:*:*:*:*:*:*:* |
|
| siemens | simotion_scout_tia |
Affected:
v5.5sp1
cpe:2.3:a:siemens:simotion_scout_tia:v5.5sp1:*:*:*:*:*:*:* |
|
| siemens | sinamics_startdrive |
Affected:
v17
cpe:2.3:a:siemens:sinamics_startdrive:v17:*:*:*:*:*:*:* |
|
| siemens | sinamics_startdrive |
Affected:
v18
cpe:2.3:a:siemens:sinamics_startdrive:v18:*:*:*:*:*:*:* |
|
| siemens | sirius_safety_es |
Affected:
0 , < v17update7
(custom)
Affected: 0 , < v18update2 (custom) cpe:2.3:a:siemens:sirius_safety_es:*:*:*:*:*:*:*:* |
|
| siemens | sirius_soft_starter_es |
Affected:
0 , < v17update7
(custom)
Affected: 0 , < v18update2 (custom) cpe:2.3:a:siemens:sirius_soft_starter_es:*:*:*:*:*:*:*:* |
|
| siemens | soft_starter_es |
Affected:
0 , < v16update7
(custom)
cpe:2.3:a:siemens:soft_starter_es:*:*:*:*:*:*:*:* |
|
| siemens | tia_portal_cloud_v3.0 |
Affected:
0 , < v18update2
(custom)
cpe:2.3:a:siemens:tia_portal_cloud_v3.0:*:*:*:*:*:*:*:* |
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:a:siemens:simatic_step_7_safety:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simatic_step_7_safety",
"vendor": "siemens",
"versions": [
{
"lessThan": "v16update7",
"status": "affected",
"version": "0",
"versionType": "custom"
},
{
"lessThan": "v17update7",
"status": "affected",
"version": "0",
"versionType": "custom"
},
{
"lessThan": "v18update2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:siemens:simatic_step_7_safety:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simatic_step_7_safety",
"vendor": "siemens",
"versions": [
{
"lessThan": "v16update7",
"status": "affected",
"version": "0",
"versionType": "custom"
},
{
"lessThan": "v17update7",
"status": "affected",
"version": "0",
"versionType": "custom"
},
{
"lessThan": "v18update2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:siemens:simatic_step_7_safety:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simatic_step_7_safety",
"vendor": "siemens",
"versions": [
{
"lessThan": "v16update7",
"status": "affected",
"version": "0",
"versionType": "custom"
},
{
"lessThan": "v17update7",
"status": "affected",
"version": "0",
"versionType": "custom"
},
{
"lessThan": "v18update2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:siemens:simatic_step_7:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simatic_step_7",
"vendor": "siemens",
"versions": [
{
"lessThan": "v16update7",
"status": "affected",
"version": "0",
"versionType": "custom"
},
{
"lessThan": "v17update7",
"status": "affected",
"version": "0",
"versionType": "custom"
},
{
"lessThan": "v18update2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:siemens:simatic_step_7:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simatic_step_7",
"vendor": "siemens",
"versions": [
{
"lessThan": "v16update7",
"status": "affected",
"version": "0",
"versionType": "custom"
},
{
"lessThan": "v17update7",
"status": "affected",
"version": "0",
"versionType": "custom"
},
{
"lessThan": "v18update2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:siemens:simatic_step_7:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simatic_step_7",
"vendor": "siemens",
"versions": [
{
"lessThan": "v16update7",
"status": "affected",
"version": "0",
"versionType": "custom"
},
{
"lessThan": "v17update7",
"status": "affected",
"version": "0",
"versionType": "custom"
},
{
"lessThan": "v18update2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:siemens:simatic_wincc_unified:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simatic_wincc_unified",
"vendor": "siemens",
"versions": [
{
"lessThan": "v16update7",
"status": "affected",
"version": "0",
"versionType": "custom"
},
{
"lessThan": "v17update7",
"status": "affected",
"version": "0",
"versionType": "custom"
},
{
"lessThan": "v18update2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:siemens:simatic_wincc_unified:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simatic_wincc_unified",
"vendor": "siemens",
"versions": [
{
"lessThan": "v16update7",
"status": "affected",
"version": "0",
"versionType": "custom"
},
{
"lessThan": "v17update7",
"status": "affected",
"version": "0",
"versionType": "custom"
},
{
"lessThan": "v18update2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:siemens:simatic_wincc_unified:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simatic_wincc_unified",
"vendor": "siemens",
"versions": [
{
"lessThan": "v16update7",
"status": "affected",
"version": "0",
"versionType": "custom"
},
{
"lessThan": "v17update7",
"status": "affected",
"version": "0",
"versionType": "custom"
},
{
"lessThan": "v18update2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:siemens:simatic_wincc:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simatic_wincc",
"vendor": "siemens",
"versions": [
{
"lessThan": "v17.7",
"status": "affected",
"version": "0",
"versionType": "custom"
},
{
"lessThan": "v18update2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:siemens:simatic_wincc:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simatic_wincc",
"vendor": "siemens",
"versions": [
{
"lessThan": "v17.7",
"status": "affected",
"version": "0",
"versionType": "custom"
},
{
"lessThan": "v18update2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:siemens:simocode_es:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simocode_es",
"vendor": "siemens",
"versions": [
{
"lessThan": "v16update7",
"status": "affected",
"version": "0",
"versionType": "custom"
},
{
"lessThan": "v17update7",
"status": "affected",
"version": "0",
"versionType": "custom"
},
{
"lessThan": "v18update2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:siemens:simocode_es:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simocode_es",
"vendor": "siemens",
"versions": [
{
"lessThan": "v16update7",
"status": "affected",
"version": "0",
"versionType": "custom"
},
{
"lessThan": "v17update7",
"status": "affected",
"version": "0",
"versionType": "custom"
},
{
"lessThan": "v18update2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:siemens:simocode_es:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simocode_es",
"vendor": "siemens",
"versions": [
{
"lessThan": "v16update7",
"status": "affected",
"version": "0",
"versionType": "custom"
},
{
"lessThan": "v17update7",
"status": "affected",
"version": "0",
"versionType": "custom"
},
{
"lessThan": "v18update2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:siemens:simotion_scout_tia:v5.4sp1:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simotion_scout_tia",
"vendor": "siemens",
"versions": [
{
"status": "affected",
"version": "v5.4sp1"
}
]
},
{
"cpes": [
"cpe:2.3:a:siemens:simotion_scout_tia:v5.4sp3:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simotion_scout_tia",
"vendor": "siemens",
"versions": [
{
"status": "affected",
"version": "v5.4sp3"
}
]
},
{
"cpes": [
"cpe:2.3:a:siemens:simotion_scout_tia:v5.5sp1:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simotion_scout_tia",
"vendor": "siemens",
"versions": [
{
"status": "affected",
"version": "v5.5sp1"
}
]
},
{
"cpes": [
"cpe:2.3:a:siemens:sinamics_startdrive:v17:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "sinamics_startdrive",
"vendor": "siemens",
"versions": [
{
"status": "affected",
"version": "v17"
}
]
},
{
"cpes": [
"cpe:2.3:a:siemens:sinamics_startdrive:v18:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "sinamics_startdrive",
"vendor": "siemens",
"versions": [
{
"status": "affected",
"version": "v18"
}
]
},
{
"cpes": [
"cpe:2.3:a:siemens:sirius_safety_es:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "sirius_safety_es",
"vendor": "siemens",
"versions": [
{
"lessThan": "v17update7",
"status": "affected",
"version": "0",
"versionType": "custom"
},
{
"lessThan": "v18update2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:siemens:sirius_safety_es:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "sirius_safety_es",
"vendor": "siemens",
"versions": [
{
"lessThan": "v17update7",
"status": "affected",
"version": "0",
"versionType": "custom"
},
{
"lessThan": "v18update2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:siemens:sirius_soft_starter_es:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "sirius_soft_starter_es",
"vendor": "siemens",
"versions": [
{
"lessThan": "v17update7",
"status": "affected",
"version": "0",
"versionType": "custom"
},
{
"lessThan": "v18update2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:siemens:sirius_soft_starter_es:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "sirius_soft_starter_es",
"vendor": "siemens",
"versions": [
{
"lessThan": "v17update7",
"status": "affected",
"version": "0",
"versionType": "custom"
},
{
"lessThan": "v18update2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:siemens:soft_starter_es:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "soft_starter_es",
"vendor": "siemens",
"versions": [
{
"lessThan": "v16update7",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:siemens:tia_portal_cloud_v3.0:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "tia_portal_cloud_v3.0",
"vendor": "siemens",
"versions": [
{
"lessThan": "v18update2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-32735",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-07-09T19:09:33.343230Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-08-27T20:32:53.425Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-02T15:25:36.815Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/html/ssa-779936.html"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "SIMATIC STEP 7 Safety V16",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V16 Update 7",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC STEP 7 Safety V17",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V17 Update 7",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC STEP 7 Safety V18",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V18 Update 2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC STEP 7 V16",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V16 Update 7",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC STEP 7 V17",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V17 Update 7",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC STEP 7 V18",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V18 Update 2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC WinCC Unified V16",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V16 Update 7",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC WinCC Unified V17",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V17 Update 7",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC WinCC Unified V18",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V18 Update 2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC WinCC V16",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V16.7",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC WinCC V17",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V17.7",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC WinCC V18",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V18 Update 2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMOCODE ES V16",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V16 Update 7",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMOCODE ES V17",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V17 Update 7",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMOCODE ES V18",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V18 Update 2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMOTION SCOUT TIA V5.4 SP1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMOTION SCOUT TIA V5.4 SP3",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMOTION SCOUT TIA V5.5 SP1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINAMICS Startdrive V16",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINAMICS Startdrive V17",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINAMICS Startdrive V18",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIRIUS Safety ES V17",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V17 Update 7",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIRIUS Safety ES V18",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V18 Update 2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIRIUS Soft Starter ES V17",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V17 Update 7",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIRIUS Soft Starter ES V18",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V18 Update 2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Soft Starter ES V16",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V16 Update 7",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "TIA Portal Cloud V3.0",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V18 Update 2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in SIMATIC STEP 7 Safety V16 (All versions \u003c V16 Update 7), SIMATIC STEP 7 Safety V17 (All versions \u003c V17 Update 7), SIMATIC STEP 7 Safety V18 (All versions \u003c V18 Update 2), SIMATIC STEP 7 V16 (All versions \u003c V16 Update 7), SIMATIC STEP 7 V17 (All versions \u003c V17 Update 7), SIMATIC STEP 7 V18 (All versions \u003c V18 Update 2), SIMATIC WinCC Unified V16 (All versions \u003c V16 Update 7), SIMATIC WinCC Unified V17 (All versions \u003c V17 Update 7), SIMATIC WinCC Unified V18 (All versions \u003c V18 Update 2), SIMATIC WinCC V16 (All versions \u003c V16.7), SIMATIC WinCC V17 (All versions \u003c V17.7), SIMATIC WinCC V18 (All versions \u003c V18 Update 2), SIMOCODE ES V16 (All versions \u003c V16 Update 7), SIMOCODE ES V17 (All versions \u003c V17 Update 7), SIMOCODE ES V18 (All versions \u003c V18 Update 2), SIMOTION SCOUT TIA V5.4 SP1 (All versions), SIMOTION SCOUT TIA V5.4 SP3 (All versions), SIMOTION SCOUT TIA V5.5 SP1 (All versions), SINAMICS Startdrive V16 (All versions), SINAMICS Startdrive V17 (All versions), SINAMICS Startdrive V18 (All versions), SIRIUS Safety ES V17 (All versions \u003c V17 Update 7), SIRIUS Safety ES V18 (All versions \u003c V18 Update 2), SIRIUS Soft Starter ES V17 (All versions \u003c V17 Update 7), SIRIUS Soft Starter ES V18 (All versions \u003c V18 Update 2), Soft Starter ES V16 (All versions \u003c V16 Update 7), TIA Portal Cloud V3.0 (All versions \u003c V18 Update 2). Affected applications do not properly restrict the .NET BinaryFormatter when deserializing hardware configuration profiles. This could allow an attacker to cause a type confusion and execute arbitrary code within the affected application.\r\n\r\nThis is the same issue that exists for .NET BinaryFormatter https://docs.microsoft.com/en-us/visualstudio/code-quality/ca2300."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
}
},
{
"cvssV4_0": {
"baseScore": 7,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:H/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-502",
"description": "CWE-502: Deserialization of Untrusted Data",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-07-09T12:04:26.871Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-779936.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2023-32735",
"datePublished": "2024-07-09T12:04:26.871Z",
"dateReserved": "2023-05-12T13:16:47.721Z",
"dateUpdated": "2025-08-27T20:32:53.425Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2020-7580 (GCVE-0-2020-7580)
Vulnerability from nvd – Published: 2020-06-10 00:00 – Updated: 2024-08-04 09:33
VLAI
EPSS
VEX
Summary
A vulnerability has been identified in SIMATIC Automation Tool (All versions < V4 SP2), SIMATIC NET PC Software V14 (All versions < V14 SP1 Update 14), SIMATIC NET PC Software V15 (All versions), SIMATIC NET PC Software V16 (All versions < V16 Upd3), SIMATIC PCS neo (All versions < V3.0 SP1), SIMATIC ProSave (All versions < V17), SIMATIC S7-1500 Software Controller (All versions < V21.8), SIMATIC STEP 7 (TIA Portal) V13 (All versions < V13 SP2 Update 4), SIMATIC STEP 7 (TIA Portal) V14 (All versions < V14 SP1 Update 10), SIMATIC STEP 7 (TIA Portal) V15 (All versions < V15.1 Update 5), SIMATIC STEP 7 (TIA Portal) V16 (All versions < V16 Update 2), SIMATIC STEP 7 V5 (All versions < V5.6 SP2 HF3), SIMATIC WinCC OA V3.16 (All versions < V3.16 P018), SIMATIC WinCC OA V3.17 (All versions < V3.17 P003), SIMATIC WinCC Runtime Advanced (All versions < V16 Update 2), SIMATIC WinCC Runtime Professional V13 (All versions < V13 SP2 Update 4), SIMATIC WinCC Runtime Professional V14 (All versions < V14 SP1 Update 10), SIMATIC WinCC Runtime Professional V15 (All versions < V15.1 Update 5), SIMATIC WinCC Runtime Professional V16 (All versions < V16 Update 2), SIMATIC WinCC V7.4 (All versions < V7.4 SP1 Update 14), SIMATIC WinCC V7.5 (All versions < V7.5 SP1 Update 3), SINAMICS STARTER (All Versions < V5.4 HF2), SINAMICS Startdrive (All Versions < V16 Update 3), SINEC NMS (All versions < V1.0 SP2), SINEMA Server (All versions < V14 SP3), SINUMERIK ONE virtual (All Versions < V6.14), SINUMERIK Operate (All Versions < V6.14). A common component used by the affected applications regularly calls a helper binary with SYSTEM privileges while the call path is not quoted. This could allow a local attacker to execute arbitrary code with SYTEM privileges.
Severity
No CVSS data available.
CWE
- CWE-428 - Unquoted Search Path or Element
Assigner
References
Impacted products
27 products
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens | SIMATIC Automation Tool |
Affected:
All versions < V4 SP2
|
|
| Siemens | SIMATIC NET PC Software V14 |
Affected:
All versions < V14 SP1 Update 14
|
|
| Siemens | SIMATIC NET PC Software V15 |
Affected:
All versions
|
|
| Siemens | SIMATIC NET PC Software V16 |
Affected:
All versions < V16 Upd3
|
|
| Siemens | SIMATIC PCS neo |
Affected:
All versions < V3.0 SP1
|
|
| Siemens | SIMATIC ProSave |
Affected:
All versions < V17
|
|
| Siemens | SIMATIC S7-1500 Software Controller |
Affected:
All versions < V21.8
|
|
| Siemens | SIMATIC STEP 7 (TIA Portal) V13 |
Affected:
All versions < V13 SP2 Update 4
|
|
| Siemens | SIMATIC STEP 7 (TIA Portal) V14 |
Affected:
All versions < V14 SP1 Update 10
|
|
| Siemens | SIMATIC STEP 7 (TIA Portal) V15 |
Affected:
All versions < V15.1 Update 5
|
|
| Siemens | SIMATIC STEP 7 (TIA Portal) V16 |
Affected:
All versions < V16 Update 2
|
|
| Siemens | SIMATIC STEP 7 V5 |
Affected:
All versions < V5.6 SP2 HF3
|
|
| Siemens | SIMATIC WinCC OA V3.16 |
Affected:
All versions < V3.16 P018
|
|
| Siemens | SIMATIC WinCC OA V3.17 |
Affected:
All versions < V3.17 P003
|
|
| Siemens | SIMATIC WinCC Runtime Advanced |
Affected:
All versions < V16 Update 2
|
|
| Siemens | SIMATIC WinCC Runtime Professional V13 |
Affected:
All versions < V13 SP2 Update 4
|
|
| Siemens | SIMATIC WinCC Runtime Professional V14 |
Affected:
All versions < V14 SP1 Update 10
|
|
| Siemens | SIMATIC WinCC Runtime Professional V15 |
Affected:
All versions < V15.1 Update 5
|
|
| Siemens | SIMATIC WinCC Runtime Professional V16 |
Affected:
All versions < V16 Update 2
|
|
| Siemens | SIMATIC WinCC V7.4 |
Affected:
All versions < V7.4 SP1 Update 14
|
|
| Siemens | SIMATIC WinCC V7.5 |
Affected:
All versions < V7.5 SP1 Update 3
|
|
| Siemens | SINAMICS STARTER |
Affected:
All Versions < V5.4 HF2
|
|
| Siemens | SINAMICS Startdrive |
Affected:
All Versions < V16 Update 3
|
|
| Siemens | SINEC NMS |
Affected:
All versions < V1.0 SP2
|
|
| Siemens | SINEMA Server |
Affected:
All versions < V14 SP3
|
|
| Siemens | SINUMERIK ONE virtual |
Affected:
All Versions < V6.14
|
|
| Siemens | SINUMERIK Operate |
Affected:
All Versions < V6.14
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T09:33:19.492Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-312271.pdf"
},
{
"tags": [
"x_transferred"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-161-04"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "SIMATIC Automation Tool",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4 SP2"
}
]
},
{
"product": "SIMATIC NET PC Software V14",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V14 SP1 Update 14"
}
]
},
{
"product": "SIMATIC NET PC Software V15",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"product": "SIMATIC NET PC Software V16",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V16 Upd3"
}
]
},
{
"product": "SIMATIC PCS neo",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.0 SP1"
}
]
},
{
"product": "SIMATIC ProSave",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V17"
}
]
},
{
"product": "SIMATIC S7-1500 Software Controller",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V21.8"
}
]
},
{
"product": "SIMATIC STEP 7 (TIA Portal) V13",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V13 SP2 Update 4"
}
]
},
{
"product": "SIMATIC STEP 7 (TIA Portal) V14",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V14 SP1 Update 10"
}
]
},
{
"product": "SIMATIC STEP 7 (TIA Portal) V15",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V15.1 Update 5"
}
]
},
{
"product": "SIMATIC STEP 7 (TIA Portal) V16",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V16 Update 2"
}
]
},
{
"product": "SIMATIC STEP 7 V5",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V5.6 SP2 HF3"
}
]
},
{
"product": "SIMATIC WinCC OA V3.16",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.16 P018"
}
]
},
{
"product": "SIMATIC WinCC OA V3.17",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.17 P003"
}
]
},
{
"product": "SIMATIC WinCC Runtime Advanced",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V16 Update 2"
}
]
},
{
"product": "SIMATIC WinCC Runtime Professional V13",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V13 SP2 Update 4"
}
]
},
{
"product": "SIMATIC WinCC Runtime Professional V14",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V14 SP1 Update 10"
}
]
},
{
"product": "SIMATIC WinCC Runtime Professional V15",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V15.1 Update 5"
}
]
},
{
"product": "SIMATIC WinCC Runtime Professional V16",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V16 Update 2"
}
]
},
{
"product": "SIMATIC WinCC V7.4",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V7.4 SP1 Update 14"
}
]
},
{
"product": "SIMATIC WinCC V7.5",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V7.5 SP1 Update 3"
}
]
},
{
"product": "SINAMICS STARTER",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All Versions \u003c V5.4 HF2"
}
]
},
{
"product": "SINAMICS Startdrive",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All Versions \u003c V16 Update 3"
}
]
},
{
"product": "SINEC NMS",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V1.0 SP2"
}
]
},
{
"product": "SINEMA Server",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V14 SP3"
}
]
},
{
"product": "SINUMERIK ONE virtual",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All Versions \u003c V6.14"
}
]
},
{
"product": "SINUMERIK Operate",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All Versions \u003c V6.14"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in SIMATIC Automation Tool (All versions \u003c V4 SP2), SIMATIC NET PC Software V14 (All versions \u003c V14 SP1 Update 14), SIMATIC NET PC Software V15 (All versions), SIMATIC NET PC Software V16 (All versions \u003c V16 Upd3), SIMATIC PCS neo (All versions \u003c V3.0 SP1), SIMATIC ProSave (All versions \u003c V17), SIMATIC S7-1500 Software Controller (All versions \u003c V21.8), SIMATIC STEP 7 (TIA Portal) V13 (All versions \u003c V13 SP2 Update 4), SIMATIC STEP 7 (TIA Portal) V14 (All versions \u003c V14 SP1 Update 10), SIMATIC STEP 7 (TIA Portal) V15 (All versions \u003c V15.1 Update 5), SIMATIC STEP 7 (TIA Portal) V16 (All versions \u003c V16 Update 2), SIMATIC STEP 7 V5 (All versions \u003c V5.6 SP2 HF3), SIMATIC WinCC OA V3.16 (All versions \u003c V3.16 P018), SIMATIC WinCC OA V3.17 (All versions \u003c V3.17 P003), SIMATIC WinCC Runtime Advanced (All versions \u003c V16 Update 2), SIMATIC WinCC Runtime Professional V13 (All versions \u003c V13 SP2 Update 4), SIMATIC WinCC Runtime Professional V14 (All versions \u003c V14 SP1 Update 10), SIMATIC WinCC Runtime Professional V15 (All versions \u003c V15.1 Update 5), SIMATIC WinCC Runtime Professional V16 (All versions \u003c V16 Update 2), SIMATIC WinCC V7.4 (All versions \u003c V7.4 SP1 Update 14), SIMATIC WinCC V7.5 (All versions \u003c V7.5 SP1 Update 3), SINAMICS STARTER (All Versions \u003c V5.4 HF2), SINAMICS Startdrive (All Versions \u003c V16 Update 3), SINEC NMS (All versions \u003c V1.0 SP2), SINEMA Server (All versions \u003c V14 SP3), SINUMERIK ONE virtual (All Versions \u003c V6.14), SINUMERIK Operate (All Versions \u003c V6.14). A common component used by the affected applications regularly calls a helper binary with SYSTEM privileges while the call path is not quoted. This could allow a local attacker to execute arbitrary code with SYTEM privileges."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-428",
"description": "CWE-428: Unquoted Search Path or Element",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-12-13T00:00:00.000Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-312271.pdf"
},
{
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-161-04"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2020-7580",
"datePublished": "2020-06-10T00:00:00.000Z",
"dateReserved": "2020-01-21T00:00:00.000Z",
"dateUpdated": "2024-08-04T09:33:19.492Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-32736 (GCVE-0-2023-32736)
Vulnerability from cvelistv5 – Published: 2024-11-12 12:49 – Updated: 2025-01-14 10:27
VLAI
EPSS
VEX
Summary
A vulnerability has been identified in SIMATIC S7-PLCSIM V16 (All versions), SIMATIC S7-PLCSIM V17 (All versions), SIMATIC STEP 7 Safety V16 (All versions), SIMATIC STEP 7 Safety V17 (All versions < V17 Update 8), SIMATIC STEP 7 Safety V18 (All versions < V18 Update 5), SIMATIC STEP 7 V16 (All versions), SIMATIC STEP 7 V17 (All versions < V17 Update 8), SIMATIC STEP 7 V18 (All versions < V18 Update 5), SIMATIC WinCC Unified V16 (All versions), SIMATIC WinCC Unified V17 (All versions < V17 Update 8), SIMATIC WinCC Unified V18 (All versions < V18 SP5), SIMATIC WinCC V16 (All versions), SIMATIC WinCC V17 (All versions < V17 Update 8), SIMATIC WinCC V18 (All versions < V18 SP5), SIMOCODE ES V16 (All versions), SIMOCODE ES V17 (All versions < V17 Update 8), SIMOCODE ES V18 (All versions), SIMOTION SCOUT TIA V5.4 SP1 (All versions), SIMOTION SCOUT TIA V5.4 SP3 (All versions), SIMOTION SCOUT TIA V5.5 SP1 (All versions), SINAMICS Startdrive V16 (All versions), SINAMICS Startdrive V17 (All versions), SINAMICS Startdrive V18 (All versions), SIRIUS Safety ES V17 (TIA Portal) (All versions < V17 Update 8), SIRIUS Safety ES V18 (TIA Portal) (All versions), SIRIUS Soft Starter ES V17 (TIA Portal) (All versions < V17 Update 8), SIRIUS Soft Starter ES V18 (TIA Portal) (All versions), TIA Portal Cloud V16 (All versions), TIA Portal Cloud V17 (All versions < V4.6.0.1), TIA Portal Cloud V18 (All versions < V4.6.1.0). Affected products do not properly sanitize user-controllable input when parsing user settings. This could allow an attacker to cause a type confusion and execute arbitrary code within the affected application.
Severity
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2024-12-02 19:49 UTC
CWE
- CWE-502 - Deserialization of Untrusted Data
Assigner
References
1 reference
Impacted products
39 products
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens | SIMATIC S7-PLCSIM V16 |
Affected:
0 , < *
(custom)
|
|
| Siemens | SIMATIC S7-PLCSIM V17 |
Affected:
0 , < *
(custom)
|
|
| Siemens | SIMATIC STEP 7 Safety V16 |
Affected:
0 , < *
(custom)
|
|
| Siemens | SIMATIC STEP 7 Safety V17 |
Affected:
0 , < V17 Update 8
(custom)
|
|
| Siemens | SIMATIC STEP 7 Safety V18 |
Affected:
0 , < V18 Update 5
(custom)
|
|
| Siemens | SIMATIC STEP 7 V16 |
Affected:
0 , < *
(custom)
|
|
| Siemens | SIMATIC STEP 7 V17 |
Affected:
0 , < V17 Update 8
(custom)
|
|
| Siemens | SIMATIC STEP 7 V18 |
Affected:
0 , < V18 Update 5
(custom)
|
|
| Siemens | SIMATIC WinCC Unified V16 |
Affected:
0 , < *
(custom)
|
|
| Siemens | SIMATIC WinCC Unified V17 |
Affected:
0 , < V17 Update 8
(custom)
|
|
| Siemens | SIMATIC WinCC Unified V18 |
Affected:
0 , < V18 SP5
(custom)
|
|
| Siemens | SIMATIC WinCC V16 |
Affected:
0 , < *
(custom)
|
|
| Siemens | SIMATIC WinCC V17 |
Affected:
0 , < V17 Update 8
(custom)
|
|
| Siemens | SIMATIC WinCC V18 |
Affected:
0 , < V18 SP5
(custom)
|
|
| Siemens | SIMOCODE ES V16 |
Affected:
0 , < *
(custom)
|
|
| Siemens | SIMOCODE ES V17 |
Affected:
0 , < V17 Update 8
(custom)
|
|
| Siemens | SIMOCODE ES V18 |
Affected:
0 , < *
(custom)
|
|
| Siemens | SIMOTION SCOUT TIA V5.4 SP1 |
Affected:
0 , < *
(custom)
|
|
| Siemens | SIMOTION SCOUT TIA V5.4 SP3 |
Affected:
0 , < *
(custom)
|
|
| Siemens | SIMOTION SCOUT TIA V5.5 SP1 |
Affected:
0 , < *
(custom)
|
|
| Siemens | SINAMICS Startdrive V16 |
Affected:
0 , < *
(custom)
|
|
| Siemens | SINAMICS Startdrive V17 |
Affected:
0 , < *
(custom)
|
|
| Siemens | SINAMICS Startdrive V18 |
Affected:
0 , < *
(custom)
|
|
| Siemens | SIRIUS Safety ES V17 (TIA Portal) |
Affected:
0 , < V17 Update 8
(custom)
|
|
| Siemens | SIRIUS Safety ES V18 (TIA Portal) |
Affected:
0 , < *
(custom)
|
|
| Siemens | SIRIUS Soft Starter ES V17 (TIA Portal) |
Affected:
0 , < V17 Update 8
(custom)
|
|
| Siemens | SIRIUS Soft Starter ES V18 (TIA Portal) |
Affected:
0 , < *
(custom)
|
|
| Siemens | TIA Portal Cloud V16 |
Affected:
0 , < *
(custom)
|
|
| Siemens | TIA Portal Cloud V17 |
Affected:
0 , < V4.6.0.1
(custom)
|
|
| Siemens | TIA Portal Cloud V18 |
Affected:
0 , < V4.6.1.0
(custom)
|
|
| siemens | simatic_step_7 |
Affected:
16 , < 17
(custom)
Affected: 17 , < 17_update8 (custom) Affected: 18 , < 18_update5 (custom) cpe:2.3:h:siemens:simatic_step_7:-:*:*:*:*:*:*:* |
|
| siemens | simatic_s7-plcsim |
Affected:
16 , < 17
(custom)
Affected: 17 , < * (custom) cpe:2.3:a:siemens:simatic_s7-plcsim:-:*:*:*:*:*:*:* |
|
| siemens | simatic_wincc |
Affected:
16 , < 17
(custom)
Affected: 17 , < 17_update8 (custom) Affected: 18 , < 18_update5 (custom) cpe:2.3:a:siemens:simatic_wincc:-:*:*:*:*:*:*:* |
|
| siemens | simatic_wincc_unified |
Affected:
16 , < 17
(custom)
Affected: 17 , < 17_update8 (custom) Affected: 18 , < 18_update5 (custom) cpe:2.3:a:siemens:simatic_wincc_unified:*:*:*:*:*:*:*:* |
|
| siemens | simocode_es |
Affected:
16 , < 17
(custom)
Affected: 17 , < 17_update8 (custom) Affected: 18 , < * (custom) cpe:2.3:a:siemens:simocode_es:-:*:*:*:*:*:*:* |
|
| siemens | simotion_scout_tia |
Affected:
v5.4sp1 , < *
(custom)
Affected: v5.4sp3 , < * (custom) Affected: v5.5sp1 , < * (custom) cpe:2.3:a:siemens:simotion_scout_tia:v5.4sp1:*:*:*:*:*:*:* cpe:2.3:a:siemens:simotion_scout_tia:v5.4sp3:*:*:*:*:*:*:* cpe:2.3:a:siemens:simotion_scout_tia:v5.5sp1:*:*:*:*:*:*:* |
|
| siemens | sinamics_startdrive |
Affected:
16 , < 17
(custom)
Affected: 17 , < 18 (custom) Affected: 18 , < * (custom) cpe:2.3:a:siemens:sinamics_startdrive:-:*:*:*:*:*:*:* |
|
| siemens | sirius_safety_es |
Affected:
0 , < 17_update8
(custom)
Affected: 18 , < * (custom) cpe:2.3:a:siemens:sirius_safety_es:*:*:*:*:*:*:*:* |
|
| siemens | tia_portal_cloud |
Affected:
16 , < *
(custom)
Affected: 17 , < * (custom) Affected: 18 , < * (custom) cpe:2.3:a:siemens:tia_portal_cloud:*:*:*:*:*:*:*:* |
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:h:siemens:simatic_step_7:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simatic_step_7",
"vendor": "siemens",
"versions": [
{
"lessThan": "17",
"status": "affected",
"version": "16",
"versionType": "custom"
},
{
"lessThan": "17_update8",
"status": "affected",
"version": "17",
"versionType": "custom"
},
{
"lessThan": "18_update5",
"status": "affected",
"version": "18",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:simatic_step_7:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simatic_step_7",
"vendor": "siemens",
"versions": [
{
"lessThan": "17",
"status": "affected",
"version": "16",
"versionType": "custom"
},
{
"lessThan": "17_update8",
"status": "affected",
"version": "17",
"versionType": "custom"
},
{
"lessThan": "18_update5",
"status": "affected",
"version": "18",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:siemens:simatic_s7-plcsim:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simatic_s7-plcsim",
"vendor": "siemens",
"versions": [
{
"lessThan": "17",
"status": "affected",
"version": "16",
"versionType": "custom"
},
{
"lessThan": "*",
"status": "affected",
"version": "17",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:siemens:simatic_wincc:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simatic_wincc",
"vendor": "siemens",
"versions": [
{
"lessThan": "17",
"status": "affected",
"version": "16",
"versionType": "custom"
},
{
"lessThan": "17_update8",
"status": "affected",
"version": "17",
"versionType": "custom"
},
{
"lessThan": "18_update5",
"status": "affected",
"version": "18",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:siemens:simatic_wincc_unified:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simatic_wincc_unified",
"vendor": "siemens",
"versions": [
{
"lessThan": "17",
"status": "affected",
"version": "16",
"versionType": "custom"
},
{
"lessThan": "17_update8",
"status": "affected",
"version": "17",
"versionType": "custom"
},
{
"lessThan": "18_update5",
"status": "affected",
"version": "18",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:siemens:simocode_es:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simocode_es",
"vendor": "siemens",
"versions": [
{
"lessThan": "17",
"status": "affected",
"version": "16",
"versionType": "custom"
},
{
"lessThan": "17_update8",
"status": "affected",
"version": "17",
"versionType": "custom"
},
{
"lessThan": "*",
"status": "affected",
"version": "18",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:siemens:simotion_scout_tia:v5.4sp1:*:*:*:*:*:*:*",
"cpe:2.3:a:siemens:simotion_scout_tia:v5.4sp3:*:*:*:*:*:*:*",
"cpe:2.3:a:siemens:simotion_scout_tia:v5.5sp1:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simotion_scout_tia",
"vendor": "siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "v5.4sp1",
"versionType": "custom"
},
{
"lessThan": "*",
"status": "affected",
"version": "v5.4sp3",
"versionType": "custom"
},
{
"lessThan": "*",
"status": "affected",
"version": "v5.5sp1",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:siemens:sinamics_startdrive:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "sinamics_startdrive",
"vendor": "siemens",
"versions": [
{
"lessThan": "17",
"status": "affected",
"version": "16",
"versionType": "custom"
},
{
"lessThan": "18",
"status": "affected",
"version": "17",
"versionType": "custom"
},
{
"lessThan": "*",
"status": "affected",
"version": "18",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:siemens:sirius_safety_es:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "sirius_safety_es",
"vendor": "siemens",
"versions": [
{
"lessThan": "17_update8",
"status": "affected",
"version": "0",
"versionType": "custom"
},
{
"lessThan": "*",
"status": "affected",
"version": "18",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:siemens:tia_portal_cloud:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "tia_portal_cloud",
"vendor": "siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "16",
"versionType": "custom"
},
{
"lessThan": "*",
"status": "affected",
"version": "17",
"versionType": "custom"
},
{
"lessThan": "*",
"status": "affected",
"version": "18",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-32736",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-12-02T19:49:50.974471Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-12-02T20:16:52.424Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-PLCSIM V16",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-PLCSIM V17",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC STEP 7 Safety V16",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC STEP 7 Safety V17",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V17 Update 8",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC STEP 7 Safety V18",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V18 Update 5",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC STEP 7 V16",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC STEP 7 V17",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V17 Update 8",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC STEP 7 V18",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V18 Update 5",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC WinCC Unified V16",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC WinCC Unified V17",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V17 Update 8",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC WinCC Unified V18",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V18 SP5",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC WinCC V16",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC WinCC V17",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V17 Update 8",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC WinCC V18",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V18 SP5",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMOCODE ES V16",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMOCODE ES V17",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V17 Update 8",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMOCODE ES V18",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMOTION SCOUT TIA V5.4 SP1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMOTION SCOUT TIA V5.4 SP3",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMOTION SCOUT TIA V5.5 SP1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINAMICS Startdrive V16",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINAMICS Startdrive V17",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINAMICS Startdrive V18",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIRIUS Safety ES V17 (TIA Portal)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V17 Update 8",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIRIUS Safety ES V18 (TIA Portal)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIRIUS Soft Starter ES V17 (TIA Portal)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V17 Update 8",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIRIUS Soft Starter ES V18 (TIA Portal)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "TIA Portal Cloud V16",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "TIA Portal Cloud V17",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6.0.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "TIA Portal Cloud V18",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.6.1.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in SIMATIC S7-PLCSIM V16 (All versions), SIMATIC S7-PLCSIM V17 (All versions), SIMATIC STEP 7 Safety V16 (All versions), SIMATIC STEP 7 Safety V17 (All versions \u003c V17 Update 8), SIMATIC STEP 7 Safety V18 (All versions \u003c V18 Update 5), SIMATIC STEP 7 V16 (All versions), SIMATIC STEP 7 V17 (All versions \u003c V17 Update 8), SIMATIC STEP 7 V18 (All versions \u003c V18 Update 5), SIMATIC WinCC Unified V16 (All versions), SIMATIC WinCC Unified V17 (All versions \u003c V17 Update 8), SIMATIC WinCC Unified V18 (All versions \u003c V18 SP5), SIMATIC WinCC V16 (All versions), SIMATIC WinCC V17 (All versions \u003c V17 Update 8), SIMATIC WinCC V18 (All versions \u003c V18 SP5), SIMOCODE ES V16 (All versions), SIMOCODE ES V17 (All versions \u003c V17 Update 8), SIMOCODE ES V18 (All versions), SIMOTION SCOUT TIA V5.4 SP1 (All versions), SIMOTION SCOUT TIA V5.4 SP3 (All versions), SIMOTION SCOUT TIA V5.5 SP1 (All versions), SINAMICS Startdrive V16 (All versions), SINAMICS Startdrive V17 (All versions), SINAMICS Startdrive V18 (All versions), SIRIUS Safety ES V17 (TIA Portal) (All versions \u003c V17 Update 8), SIRIUS Safety ES V18 (TIA Portal) (All versions), SIRIUS Soft Starter ES V17 (TIA Portal) (All versions \u003c V17 Update 8), SIRIUS Soft Starter ES V18 (TIA Portal) (All versions), TIA Portal Cloud V16 (All versions), TIA Portal Cloud V17 (All versions \u003c V4.6.0.1), TIA Portal Cloud V18 (All versions \u003c V4.6.1.0). Affected products do not properly sanitize user-controllable input when parsing user settings. This could allow an attacker to cause a type confusion and execute arbitrary code within the affected application."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 7.3,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
}
},
{
"cvssV4_0": {
"baseScore": 7,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-502",
"description": "CWE-502: Deserialization of Untrusted Data",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-01-14T10:27:17.694Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-871035.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2023-32736",
"datePublished": "2024-11-12T12:49:22.651Z",
"dateReserved": "2023-05-12T13:16:47.721Z",
"dateUpdated": "2025-01-14T10:27:17.694Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-32735 (GCVE-0-2023-32735)
Vulnerability from cvelistv5 – Published: 2024-07-09 12:04 – Updated: 2025-08-27 20:32
VLAI
EPSS
VEX
Summary
A vulnerability has been identified in SIMATIC STEP 7 Safety V16 (All versions < V16 Update 7), SIMATIC STEP 7 Safety V17 (All versions < V17 Update 7), SIMATIC STEP 7 Safety V18 (All versions < V18 Update 2), SIMATIC STEP 7 V16 (All versions < V16 Update 7), SIMATIC STEP 7 V17 (All versions < V17 Update 7), SIMATIC STEP 7 V18 (All versions < V18 Update 2), SIMATIC WinCC Unified V16 (All versions < V16 Update 7), SIMATIC WinCC Unified V17 (All versions < V17 Update 7), SIMATIC WinCC Unified V18 (All versions < V18 Update 2), SIMATIC WinCC V16 (All versions < V16.7), SIMATIC WinCC V17 (All versions < V17.7), SIMATIC WinCC V18 (All versions < V18 Update 2), SIMOCODE ES V16 (All versions < V16 Update 7), SIMOCODE ES V17 (All versions < V17 Update 7), SIMOCODE ES V18 (All versions < V18 Update 2), SIMOTION SCOUT TIA V5.4 SP1 (All versions), SIMOTION SCOUT TIA V5.4 SP3 (All versions), SIMOTION SCOUT TIA V5.5 SP1 (All versions), SINAMICS Startdrive V16 (All versions), SINAMICS Startdrive V17 (All versions), SINAMICS Startdrive V18 (All versions), SIRIUS Safety ES V17 (All versions < V17 Update 7), SIRIUS Safety ES V18 (All versions < V18 Update 2), SIRIUS Soft Starter ES V17 (All versions < V17 Update 7), SIRIUS Soft Starter ES V18 (All versions < V18 Update 2), Soft Starter ES V16 (All versions < V16 Update 7), TIA Portal Cloud V3.0 (All versions < V18 Update 2). Affected applications do not properly restrict the .NET BinaryFormatter when deserializing hardware configuration profiles. This could allow an attacker to cause a type confusion and execute arbitrary code within the affected application.
This is the same issue that exists for .NET BinaryFormatter https://docs.microsoft.com/en-us/visualstudio/code-quality/ca2300.
Severity
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2024-07-09 19:09 UTC
CWE
- CWE-502 - Deserialization of Untrusted Data
Assigner
References
1 reference
Impacted products
41 products
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens | SIMATIC STEP 7 Safety V16 |
Affected:
0 , < V16 Update 7
(custom)
|
|
| Siemens | SIMATIC STEP 7 Safety V17 |
Affected:
0 , < V17 Update 7
(custom)
|
|
| Siemens | SIMATIC STEP 7 Safety V18 |
Affected:
0 , < V18 Update 2
(custom)
|
|
| Siemens | SIMATIC STEP 7 V16 |
Affected:
0 , < V16 Update 7
(custom)
|
|
| Siemens | SIMATIC STEP 7 V17 |
Affected:
0 , < V17 Update 7
(custom)
|
|
| Siemens | SIMATIC STEP 7 V18 |
Affected:
0 , < V18 Update 2
(custom)
|
|
| Siemens | SIMATIC WinCC Unified V16 |
Affected:
0 , < V16 Update 7
(custom)
|
|
| Siemens | SIMATIC WinCC Unified V17 |
Affected:
0 , < V17 Update 7
(custom)
|
|
| Siemens | SIMATIC WinCC Unified V18 |
Affected:
0 , < V18 Update 2
(custom)
|
|
| Siemens | SIMATIC WinCC V16 |
Affected:
0 , < V16.7
(custom)
|
|
| Siemens | SIMATIC WinCC V17 |
Affected:
0 , < V17.7
(custom)
|
|
| Siemens | SIMATIC WinCC V18 |
Affected:
0 , < V18 Update 2
(custom)
|
|
| Siemens | SIMOCODE ES V16 |
Affected:
0 , < V16 Update 7
(custom)
|
|
| Siemens | SIMOCODE ES V17 |
Affected:
0 , < V17 Update 7
(custom)
|
|
| Siemens | SIMOCODE ES V18 |
Affected:
0 , < V18 Update 2
(custom)
|
|
| Siemens | SIMOTION SCOUT TIA V5.4 SP1 |
Affected:
0 , < *
(custom)
|
|
| Siemens | SIMOTION SCOUT TIA V5.4 SP3 |
Affected:
0 , < *
(custom)
|
|
| Siemens | SIMOTION SCOUT TIA V5.5 SP1 |
Affected:
0 , < *
(custom)
|
|
| Siemens | SINAMICS Startdrive V16 |
Affected:
0 , < *
(custom)
|
|
| Siemens | SINAMICS Startdrive V17 |
Affected:
0 , < *
(custom)
|
|
| Siemens | SINAMICS Startdrive V18 |
Affected:
0 , < *
(custom)
|
|
| Siemens | SIRIUS Safety ES V17 |
Affected:
0 , < V17 Update 7
(custom)
|
|
| Siemens | SIRIUS Safety ES V18 |
Affected:
0 , < V18 Update 2
(custom)
|
|
| Siemens | SIRIUS Soft Starter ES V17 |
Affected:
0 , < V17 Update 7
(custom)
|
|
| Siemens | SIRIUS Soft Starter ES V18 |
Affected:
0 , < V18 Update 2
(custom)
|
|
| Siemens | Soft Starter ES V16 |
Affected:
0 , < V16 Update 7
(custom)
|
|
| Siemens | TIA Portal Cloud V3.0 |
Affected:
0 , < V18 Update 2
(custom)
|
|
| siemens | simatic_step_7_safety |
Affected:
0 , < v16update7
(custom)
Affected: 0 , < v17update7 (custom) Affected: 0 , < v18update2 (custom) cpe:2.3:a:siemens:simatic_step_7_safety:*:*:*:*:*:*:*:* |
|
| siemens | simatic_step_7 |
Affected:
0 , < v16update7
(custom)
Affected: 0 , < v17update7 (custom) Affected: 0 , < v18update2 (custom) cpe:2.3:a:siemens:simatic_step_7:*:*:*:*:*:*:*:* |
|
| siemens | simatic_wincc_unified |
Affected:
0 , < v16update7
(custom)
Affected: 0 , < v17update7 (custom) Affected: 0 , < v18update2 (custom) cpe:2.3:a:siemens:simatic_wincc_unified:*:*:*:*:*:*:*:* |
|
| siemens | simatic_wincc |
Affected:
0 , < v17.7
(custom)
Affected: 0 , < v18update2 (custom) cpe:2.3:a:siemens:simatic_wincc:*:*:*:*:*:*:*:* |
|
| siemens | simocode_es |
Affected:
0 , < v16update7
(custom)
Affected: 0 , < v17update7 (custom) Affected: 0 , < v18update2 (custom) cpe:2.3:a:siemens:simocode_es:*:*:*:*:*:*:*:* |
|
| siemens | simotion_scout_tia |
Affected:
v5.4sp1
cpe:2.3:a:siemens:simotion_scout_tia:v5.4sp1:*:*:*:*:*:*:* |
|
| siemens | simotion_scout_tia |
Affected:
v5.4sp3
cpe:2.3:a:siemens:simotion_scout_tia:v5.4sp3:*:*:*:*:*:*:* |
|
| siemens | simotion_scout_tia |
Affected:
v5.5sp1
cpe:2.3:a:siemens:simotion_scout_tia:v5.5sp1:*:*:*:*:*:*:* |
|
| siemens | sinamics_startdrive |
Affected:
v17
cpe:2.3:a:siemens:sinamics_startdrive:v17:*:*:*:*:*:*:* |
|
| siemens | sinamics_startdrive |
Affected:
v18
cpe:2.3:a:siemens:sinamics_startdrive:v18:*:*:*:*:*:*:* |
|
| siemens | sirius_safety_es |
Affected:
0 , < v17update7
(custom)
Affected: 0 , < v18update2 (custom) cpe:2.3:a:siemens:sirius_safety_es:*:*:*:*:*:*:*:* |
|
| siemens | sirius_soft_starter_es |
Affected:
0 , < v17update7
(custom)
Affected: 0 , < v18update2 (custom) cpe:2.3:a:siemens:sirius_soft_starter_es:*:*:*:*:*:*:*:* |
|
| siemens | soft_starter_es |
Affected:
0 , < v16update7
(custom)
cpe:2.3:a:siemens:soft_starter_es:*:*:*:*:*:*:*:* |
|
| siemens | tia_portal_cloud_v3.0 |
Affected:
0 , < v18update2
(custom)
cpe:2.3:a:siemens:tia_portal_cloud_v3.0:*:*:*:*:*:*:*:* |
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:a:siemens:simatic_step_7_safety:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simatic_step_7_safety",
"vendor": "siemens",
"versions": [
{
"lessThan": "v16update7",
"status": "affected",
"version": "0",
"versionType": "custom"
},
{
"lessThan": "v17update7",
"status": "affected",
"version": "0",
"versionType": "custom"
},
{
"lessThan": "v18update2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:siemens:simatic_step_7_safety:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simatic_step_7_safety",
"vendor": "siemens",
"versions": [
{
"lessThan": "v16update7",
"status": "affected",
"version": "0",
"versionType": "custom"
},
{
"lessThan": "v17update7",
"status": "affected",
"version": "0",
"versionType": "custom"
},
{
"lessThan": "v18update2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:siemens:simatic_step_7_safety:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simatic_step_7_safety",
"vendor": "siemens",
"versions": [
{
"lessThan": "v16update7",
"status": "affected",
"version": "0",
"versionType": "custom"
},
{
"lessThan": "v17update7",
"status": "affected",
"version": "0",
"versionType": "custom"
},
{
"lessThan": "v18update2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:siemens:simatic_step_7:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simatic_step_7",
"vendor": "siemens",
"versions": [
{
"lessThan": "v16update7",
"status": "affected",
"version": "0",
"versionType": "custom"
},
{
"lessThan": "v17update7",
"status": "affected",
"version": "0",
"versionType": "custom"
},
{
"lessThan": "v18update2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:siemens:simatic_step_7:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simatic_step_7",
"vendor": "siemens",
"versions": [
{
"lessThan": "v16update7",
"status": "affected",
"version": "0",
"versionType": "custom"
},
{
"lessThan": "v17update7",
"status": "affected",
"version": "0",
"versionType": "custom"
},
{
"lessThan": "v18update2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:siemens:simatic_step_7:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simatic_step_7",
"vendor": "siemens",
"versions": [
{
"lessThan": "v16update7",
"status": "affected",
"version": "0",
"versionType": "custom"
},
{
"lessThan": "v17update7",
"status": "affected",
"version": "0",
"versionType": "custom"
},
{
"lessThan": "v18update2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:siemens:simatic_wincc_unified:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simatic_wincc_unified",
"vendor": "siemens",
"versions": [
{
"lessThan": "v16update7",
"status": "affected",
"version": "0",
"versionType": "custom"
},
{
"lessThan": "v17update7",
"status": "affected",
"version": "0",
"versionType": "custom"
},
{
"lessThan": "v18update2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:siemens:simatic_wincc_unified:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simatic_wincc_unified",
"vendor": "siemens",
"versions": [
{
"lessThan": "v16update7",
"status": "affected",
"version": "0",
"versionType": "custom"
},
{
"lessThan": "v17update7",
"status": "affected",
"version": "0",
"versionType": "custom"
},
{
"lessThan": "v18update2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:siemens:simatic_wincc_unified:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simatic_wincc_unified",
"vendor": "siemens",
"versions": [
{
"lessThan": "v16update7",
"status": "affected",
"version": "0",
"versionType": "custom"
},
{
"lessThan": "v17update7",
"status": "affected",
"version": "0",
"versionType": "custom"
},
{
"lessThan": "v18update2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:siemens:simatic_wincc:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simatic_wincc",
"vendor": "siemens",
"versions": [
{
"lessThan": "v17.7",
"status": "affected",
"version": "0",
"versionType": "custom"
},
{
"lessThan": "v18update2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:siemens:simatic_wincc:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simatic_wincc",
"vendor": "siemens",
"versions": [
{
"lessThan": "v17.7",
"status": "affected",
"version": "0",
"versionType": "custom"
},
{
"lessThan": "v18update2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:siemens:simocode_es:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simocode_es",
"vendor": "siemens",
"versions": [
{
"lessThan": "v16update7",
"status": "affected",
"version": "0",
"versionType": "custom"
},
{
"lessThan": "v17update7",
"status": "affected",
"version": "0",
"versionType": "custom"
},
{
"lessThan": "v18update2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:siemens:simocode_es:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simocode_es",
"vendor": "siemens",
"versions": [
{
"lessThan": "v16update7",
"status": "affected",
"version": "0",
"versionType": "custom"
},
{
"lessThan": "v17update7",
"status": "affected",
"version": "0",
"versionType": "custom"
},
{
"lessThan": "v18update2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:siemens:simocode_es:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simocode_es",
"vendor": "siemens",
"versions": [
{
"lessThan": "v16update7",
"status": "affected",
"version": "0",
"versionType": "custom"
},
{
"lessThan": "v17update7",
"status": "affected",
"version": "0",
"versionType": "custom"
},
{
"lessThan": "v18update2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:siemens:simotion_scout_tia:v5.4sp1:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simotion_scout_tia",
"vendor": "siemens",
"versions": [
{
"status": "affected",
"version": "v5.4sp1"
}
]
},
{
"cpes": [
"cpe:2.3:a:siemens:simotion_scout_tia:v5.4sp3:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simotion_scout_tia",
"vendor": "siemens",
"versions": [
{
"status": "affected",
"version": "v5.4sp3"
}
]
},
{
"cpes": [
"cpe:2.3:a:siemens:simotion_scout_tia:v5.5sp1:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simotion_scout_tia",
"vendor": "siemens",
"versions": [
{
"status": "affected",
"version": "v5.5sp1"
}
]
},
{
"cpes": [
"cpe:2.3:a:siemens:sinamics_startdrive:v17:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "sinamics_startdrive",
"vendor": "siemens",
"versions": [
{
"status": "affected",
"version": "v17"
}
]
},
{
"cpes": [
"cpe:2.3:a:siemens:sinamics_startdrive:v18:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "sinamics_startdrive",
"vendor": "siemens",
"versions": [
{
"status": "affected",
"version": "v18"
}
]
},
{
"cpes": [
"cpe:2.3:a:siemens:sirius_safety_es:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "sirius_safety_es",
"vendor": "siemens",
"versions": [
{
"lessThan": "v17update7",
"status": "affected",
"version": "0",
"versionType": "custom"
},
{
"lessThan": "v18update2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:siemens:sirius_safety_es:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "sirius_safety_es",
"vendor": "siemens",
"versions": [
{
"lessThan": "v17update7",
"status": "affected",
"version": "0",
"versionType": "custom"
},
{
"lessThan": "v18update2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:siemens:sirius_soft_starter_es:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "sirius_soft_starter_es",
"vendor": "siemens",
"versions": [
{
"lessThan": "v17update7",
"status": "affected",
"version": "0",
"versionType": "custom"
},
{
"lessThan": "v18update2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:siemens:sirius_soft_starter_es:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "sirius_soft_starter_es",
"vendor": "siemens",
"versions": [
{
"lessThan": "v17update7",
"status": "affected",
"version": "0",
"versionType": "custom"
},
{
"lessThan": "v18update2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:siemens:soft_starter_es:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "soft_starter_es",
"vendor": "siemens",
"versions": [
{
"lessThan": "v16update7",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:siemens:tia_portal_cloud_v3.0:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "tia_portal_cloud_v3.0",
"vendor": "siemens",
"versions": [
{
"lessThan": "v18update2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-32735",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-07-09T19:09:33.343230Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-08-27T20:32:53.425Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-02T15:25:36.815Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/html/ssa-779936.html"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "SIMATIC STEP 7 Safety V16",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V16 Update 7",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC STEP 7 Safety V17",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V17 Update 7",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC STEP 7 Safety V18",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V18 Update 2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC STEP 7 V16",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V16 Update 7",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC STEP 7 V17",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V17 Update 7",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC STEP 7 V18",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V18 Update 2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC WinCC Unified V16",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V16 Update 7",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC WinCC Unified V17",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V17 Update 7",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC WinCC Unified V18",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V18 Update 2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC WinCC V16",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V16.7",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC WinCC V17",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V17.7",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC WinCC V18",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V18 Update 2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMOCODE ES V16",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V16 Update 7",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMOCODE ES V17",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V17 Update 7",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMOCODE ES V18",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V18 Update 2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMOTION SCOUT TIA V5.4 SP1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMOTION SCOUT TIA V5.4 SP3",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMOTION SCOUT TIA V5.5 SP1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINAMICS Startdrive V16",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINAMICS Startdrive V17",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINAMICS Startdrive V18",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIRIUS Safety ES V17",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V17 Update 7",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIRIUS Safety ES V18",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V18 Update 2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIRIUS Soft Starter ES V17",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V17 Update 7",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIRIUS Soft Starter ES V18",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V18 Update 2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Soft Starter ES V16",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V16 Update 7",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "TIA Portal Cloud V3.0",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V18 Update 2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in SIMATIC STEP 7 Safety V16 (All versions \u003c V16 Update 7), SIMATIC STEP 7 Safety V17 (All versions \u003c V17 Update 7), SIMATIC STEP 7 Safety V18 (All versions \u003c V18 Update 2), SIMATIC STEP 7 V16 (All versions \u003c V16 Update 7), SIMATIC STEP 7 V17 (All versions \u003c V17 Update 7), SIMATIC STEP 7 V18 (All versions \u003c V18 Update 2), SIMATIC WinCC Unified V16 (All versions \u003c V16 Update 7), SIMATIC WinCC Unified V17 (All versions \u003c V17 Update 7), SIMATIC WinCC Unified V18 (All versions \u003c V18 Update 2), SIMATIC WinCC V16 (All versions \u003c V16.7), SIMATIC WinCC V17 (All versions \u003c V17.7), SIMATIC WinCC V18 (All versions \u003c V18 Update 2), SIMOCODE ES V16 (All versions \u003c V16 Update 7), SIMOCODE ES V17 (All versions \u003c V17 Update 7), SIMOCODE ES V18 (All versions \u003c V18 Update 2), SIMOTION SCOUT TIA V5.4 SP1 (All versions), SIMOTION SCOUT TIA V5.4 SP3 (All versions), SIMOTION SCOUT TIA V5.5 SP1 (All versions), SINAMICS Startdrive V16 (All versions), SINAMICS Startdrive V17 (All versions), SINAMICS Startdrive V18 (All versions), SIRIUS Safety ES V17 (All versions \u003c V17 Update 7), SIRIUS Safety ES V18 (All versions \u003c V18 Update 2), SIRIUS Soft Starter ES V17 (All versions \u003c V17 Update 7), SIRIUS Soft Starter ES V18 (All versions \u003c V18 Update 2), Soft Starter ES V16 (All versions \u003c V16 Update 7), TIA Portal Cloud V3.0 (All versions \u003c V18 Update 2). Affected applications do not properly restrict the .NET BinaryFormatter when deserializing hardware configuration profiles. This could allow an attacker to cause a type confusion and execute arbitrary code within the affected application.\r\n\r\nThis is the same issue that exists for .NET BinaryFormatter https://docs.microsoft.com/en-us/visualstudio/code-quality/ca2300."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
}
},
{
"cvssV4_0": {
"baseScore": 7,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:H/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-502",
"description": "CWE-502: Deserialization of Untrusted Data",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-07-09T12:04:26.871Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-779936.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2023-32735",
"datePublished": "2024-07-09T12:04:26.871Z",
"dateReserved": "2023-05-12T13:16:47.721Z",
"dateUpdated": "2025-08-27T20:32:53.425Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2020-7580 (GCVE-0-2020-7580)
Vulnerability from cvelistv5 – Published: 2020-06-10 00:00 – Updated: 2024-08-04 09:33
VLAI
EPSS
VEX
Summary
A vulnerability has been identified in SIMATIC Automation Tool (All versions < V4 SP2), SIMATIC NET PC Software V14 (All versions < V14 SP1 Update 14), SIMATIC NET PC Software V15 (All versions), SIMATIC NET PC Software V16 (All versions < V16 Upd3), SIMATIC PCS neo (All versions < V3.0 SP1), SIMATIC ProSave (All versions < V17), SIMATIC S7-1500 Software Controller (All versions < V21.8), SIMATIC STEP 7 (TIA Portal) V13 (All versions < V13 SP2 Update 4), SIMATIC STEP 7 (TIA Portal) V14 (All versions < V14 SP1 Update 10), SIMATIC STEP 7 (TIA Portal) V15 (All versions < V15.1 Update 5), SIMATIC STEP 7 (TIA Portal) V16 (All versions < V16 Update 2), SIMATIC STEP 7 V5 (All versions < V5.6 SP2 HF3), SIMATIC WinCC OA V3.16 (All versions < V3.16 P018), SIMATIC WinCC OA V3.17 (All versions < V3.17 P003), SIMATIC WinCC Runtime Advanced (All versions < V16 Update 2), SIMATIC WinCC Runtime Professional V13 (All versions < V13 SP2 Update 4), SIMATIC WinCC Runtime Professional V14 (All versions < V14 SP1 Update 10), SIMATIC WinCC Runtime Professional V15 (All versions < V15.1 Update 5), SIMATIC WinCC Runtime Professional V16 (All versions < V16 Update 2), SIMATIC WinCC V7.4 (All versions < V7.4 SP1 Update 14), SIMATIC WinCC V7.5 (All versions < V7.5 SP1 Update 3), SINAMICS STARTER (All Versions < V5.4 HF2), SINAMICS Startdrive (All Versions < V16 Update 3), SINEC NMS (All versions < V1.0 SP2), SINEMA Server (All versions < V14 SP3), SINUMERIK ONE virtual (All Versions < V6.14), SINUMERIK Operate (All Versions < V6.14). A common component used by the affected applications regularly calls a helper binary with SYSTEM privileges while the call path is not quoted. This could allow a local attacker to execute arbitrary code with SYTEM privileges.
Severity
No CVSS data available.
CWE
- CWE-428 - Unquoted Search Path or Element
Assigner
References
Impacted products
27 products
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens | SIMATIC Automation Tool |
Affected:
All versions < V4 SP2
|
|
| Siemens | SIMATIC NET PC Software V14 |
Affected:
All versions < V14 SP1 Update 14
|
|
| Siemens | SIMATIC NET PC Software V15 |
Affected:
All versions
|
|
| Siemens | SIMATIC NET PC Software V16 |
Affected:
All versions < V16 Upd3
|
|
| Siemens | SIMATIC PCS neo |
Affected:
All versions < V3.0 SP1
|
|
| Siemens | SIMATIC ProSave |
Affected:
All versions < V17
|
|
| Siemens | SIMATIC S7-1500 Software Controller |
Affected:
All versions < V21.8
|
|
| Siemens | SIMATIC STEP 7 (TIA Portal) V13 |
Affected:
All versions < V13 SP2 Update 4
|
|
| Siemens | SIMATIC STEP 7 (TIA Portal) V14 |
Affected:
All versions < V14 SP1 Update 10
|
|
| Siemens | SIMATIC STEP 7 (TIA Portal) V15 |
Affected:
All versions < V15.1 Update 5
|
|
| Siemens | SIMATIC STEP 7 (TIA Portal) V16 |
Affected:
All versions < V16 Update 2
|
|
| Siemens | SIMATIC STEP 7 V5 |
Affected:
All versions < V5.6 SP2 HF3
|
|
| Siemens | SIMATIC WinCC OA V3.16 |
Affected:
All versions < V3.16 P018
|
|
| Siemens | SIMATIC WinCC OA V3.17 |
Affected:
All versions < V3.17 P003
|
|
| Siemens | SIMATIC WinCC Runtime Advanced |
Affected:
All versions < V16 Update 2
|
|
| Siemens | SIMATIC WinCC Runtime Professional V13 |
Affected:
All versions < V13 SP2 Update 4
|
|
| Siemens | SIMATIC WinCC Runtime Professional V14 |
Affected:
All versions < V14 SP1 Update 10
|
|
| Siemens | SIMATIC WinCC Runtime Professional V15 |
Affected:
All versions < V15.1 Update 5
|
|
| Siemens | SIMATIC WinCC Runtime Professional V16 |
Affected:
All versions < V16 Update 2
|
|
| Siemens | SIMATIC WinCC V7.4 |
Affected:
All versions < V7.4 SP1 Update 14
|
|
| Siemens | SIMATIC WinCC V7.5 |
Affected:
All versions < V7.5 SP1 Update 3
|
|
| Siemens | SINAMICS STARTER |
Affected:
All Versions < V5.4 HF2
|
|
| Siemens | SINAMICS Startdrive |
Affected:
All Versions < V16 Update 3
|
|
| Siemens | SINEC NMS |
Affected:
All versions < V1.0 SP2
|
|
| Siemens | SINEMA Server |
Affected:
All versions < V14 SP3
|
|
| Siemens | SINUMERIK ONE virtual |
Affected:
All Versions < V6.14
|
|
| Siemens | SINUMERIK Operate |
Affected:
All Versions < V6.14
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T09:33:19.492Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-312271.pdf"
},
{
"tags": [
"x_transferred"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-161-04"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "SIMATIC Automation Tool",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4 SP2"
}
]
},
{
"product": "SIMATIC NET PC Software V14",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V14 SP1 Update 14"
}
]
},
{
"product": "SIMATIC NET PC Software V15",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"product": "SIMATIC NET PC Software V16",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V16 Upd3"
}
]
},
{
"product": "SIMATIC PCS neo",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.0 SP1"
}
]
},
{
"product": "SIMATIC ProSave",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V17"
}
]
},
{
"product": "SIMATIC S7-1500 Software Controller",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V21.8"
}
]
},
{
"product": "SIMATIC STEP 7 (TIA Portal) V13",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V13 SP2 Update 4"
}
]
},
{
"product": "SIMATIC STEP 7 (TIA Portal) V14",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V14 SP1 Update 10"
}
]
},
{
"product": "SIMATIC STEP 7 (TIA Portal) V15",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V15.1 Update 5"
}
]
},
{
"product": "SIMATIC STEP 7 (TIA Portal) V16",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V16 Update 2"
}
]
},
{
"product": "SIMATIC STEP 7 V5",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V5.6 SP2 HF3"
}
]
},
{
"product": "SIMATIC WinCC OA V3.16",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.16 P018"
}
]
},
{
"product": "SIMATIC WinCC OA V3.17",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.17 P003"
}
]
},
{
"product": "SIMATIC WinCC Runtime Advanced",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V16 Update 2"
}
]
},
{
"product": "SIMATIC WinCC Runtime Professional V13",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V13 SP2 Update 4"
}
]
},
{
"product": "SIMATIC WinCC Runtime Professional V14",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V14 SP1 Update 10"
}
]
},
{
"product": "SIMATIC WinCC Runtime Professional V15",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V15.1 Update 5"
}
]
},
{
"product": "SIMATIC WinCC Runtime Professional V16",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V16 Update 2"
}
]
},
{
"product": "SIMATIC WinCC V7.4",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V7.4 SP1 Update 14"
}
]
},
{
"product": "SIMATIC WinCC V7.5",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V7.5 SP1 Update 3"
}
]
},
{
"product": "SINAMICS STARTER",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All Versions \u003c V5.4 HF2"
}
]
},
{
"product": "SINAMICS Startdrive",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All Versions \u003c V16 Update 3"
}
]
},
{
"product": "SINEC NMS",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V1.0 SP2"
}
]
},
{
"product": "SINEMA Server",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V14 SP3"
}
]
},
{
"product": "SINUMERIK ONE virtual",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All Versions \u003c V6.14"
}
]
},
{
"product": "SINUMERIK Operate",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All Versions \u003c V6.14"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in SIMATIC Automation Tool (All versions \u003c V4 SP2), SIMATIC NET PC Software V14 (All versions \u003c V14 SP1 Update 14), SIMATIC NET PC Software V15 (All versions), SIMATIC NET PC Software V16 (All versions \u003c V16 Upd3), SIMATIC PCS neo (All versions \u003c V3.0 SP1), SIMATIC ProSave (All versions \u003c V17), SIMATIC S7-1500 Software Controller (All versions \u003c V21.8), SIMATIC STEP 7 (TIA Portal) V13 (All versions \u003c V13 SP2 Update 4), SIMATIC STEP 7 (TIA Portal) V14 (All versions \u003c V14 SP1 Update 10), SIMATIC STEP 7 (TIA Portal) V15 (All versions \u003c V15.1 Update 5), SIMATIC STEP 7 (TIA Portal) V16 (All versions \u003c V16 Update 2), SIMATIC STEP 7 V5 (All versions \u003c V5.6 SP2 HF3), SIMATIC WinCC OA V3.16 (All versions \u003c V3.16 P018), SIMATIC WinCC OA V3.17 (All versions \u003c V3.17 P003), SIMATIC WinCC Runtime Advanced (All versions \u003c V16 Update 2), SIMATIC WinCC Runtime Professional V13 (All versions \u003c V13 SP2 Update 4), SIMATIC WinCC Runtime Professional V14 (All versions \u003c V14 SP1 Update 10), SIMATIC WinCC Runtime Professional V15 (All versions \u003c V15.1 Update 5), SIMATIC WinCC Runtime Professional V16 (All versions \u003c V16 Update 2), SIMATIC WinCC V7.4 (All versions \u003c V7.4 SP1 Update 14), SIMATIC WinCC V7.5 (All versions \u003c V7.5 SP1 Update 3), SINAMICS STARTER (All Versions \u003c V5.4 HF2), SINAMICS Startdrive (All Versions \u003c V16 Update 3), SINEC NMS (All versions \u003c V1.0 SP2), SINEMA Server (All versions \u003c V14 SP3), SINUMERIK ONE virtual (All Versions \u003c V6.14), SINUMERIK Operate (All Versions \u003c V6.14). A common component used by the affected applications regularly calls a helper binary with SYSTEM privileges while the call path is not quoted. This could allow a local attacker to execute arbitrary code with SYTEM privileges."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-428",
"description": "CWE-428: Unquoted Search Path or Element",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-12-13T00:00:00.000Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-312271.pdf"
},
{
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-161-04"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2020-7580",
"datePublished": "2020-06-10T00:00:00.000Z",
"dateReserved": "2020-01-21T00:00:00.000Z",
"dateUpdated": "2024-08-04T09:33:19.492Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}