Search

Find a vulnerability

Search criteria

    4 vulnerabilities found for simotion_p320-4_s_firmware by siemens

    CVE-2023-27465 (GCVE-0-2023-27465)

    Vulnerability from nvd – Published: 2023-06-13 08:17 – Updated: 2024-08-02 12:09
    VLAI
    Summary
    A vulnerability has been identified in SIMOTION C240 (All versions >= V5.4 < V5.5 SP1), SIMOTION C240 PN (All versions >= V5.4 < V5.5 SP1), SIMOTION D410-2 DP (All versions >= V5.4 < V5.5 SP1), SIMOTION D410-2 DP/PN (All versions >= V5.4 < V5.5 SP1), SIMOTION D425-2 DP (All versions >= V5.4 < V5.5 SP1), SIMOTION D425-2 DP/PN (All versions >= V5.4 < V5.5 SP1), SIMOTION D435-2 DP (All versions >= V5.4 < V5.5 SP1), SIMOTION D435-2 DP/PN (All versions >= V5.4 < V5.5 SP1), SIMOTION D445-2 DP/PN (All versions >= V5.4), SIMOTION D445-2 DP/PN (All versions >= V5.4 < V5.5 SP1), SIMOTION D455-2 DP/PN (All versions >= V5.4 < V5.5 SP1), SIMOTION P320-4 E (All versions >= V5.4), SIMOTION P320-4 S (All versions >= V5.4). When operated with Security Level Low the device does not protect access to certain services relevant for debugging. This could allow an unauthenticated attacker to extract confidential technology object (TO) configuration from the device.
    CWE
    • CWE-213 - Exposure of Sensitive Information Due to Incompatible Policies
    Assigner
    Impacted products
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T12:09:43.410Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-482956.pdf"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unknown",
              "product": "SIMOTION C240",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003e= V5.4 \u003c V5.5 SP1"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMOTION C240 PN",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003e= V5.4 \u003c V5.5 SP1"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMOTION D410-2 DP",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003e= V5.4 \u003c V5.5 SP1"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMOTION D410-2 DP/PN",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003e= V5.4 \u003c V5.5 SP1"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMOTION D425-2 DP",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003e= V5.4 \u003c V5.5 SP1"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMOTION D425-2 DP/PN",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003e= V5.4 \u003c V5.5 SP1"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMOTION D435-2 DP",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003e= V5.4 \u003c V5.5 SP1"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMOTION D435-2 DP/PN",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003e= V5.4 \u003c V5.5 SP1"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMOTION D445-2 DP/PN",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003e= V5.4"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMOTION D445-2 DP/PN",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003e= V5.4 \u003c V5.5 SP1"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMOTION D455-2 DP/PN",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003e= V5.4 \u003c V5.5 SP1"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMOTION P320-4 E",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003e= V5.4"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMOTION P320-4 S",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003e= V5.4"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability has been identified in SIMOTION C240 (All versions \u003e= V5.4 \u003c V5.5 SP1), SIMOTION C240 PN (All versions \u003e= V5.4 \u003c V5.5 SP1), SIMOTION D410-2 DP (All versions \u003e= V5.4 \u003c V5.5 SP1), SIMOTION D410-2 DP/PN (All versions \u003e= V5.4 \u003c V5.5 SP1), SIMOTION D425-2 DP (All versions \u003e= V5.4 \u003c V5.5 SP1), SIMOTION D425-2 DP/PN (All versions \u003e= V5.4 \u003c V5.5 SP1), SIMOTION D435-2 DP (All versions \u003e= V5.4 \u003c V5.5 SP1), SIMOTION D435-2 DP/PN (All versions \u003e= V5.4 \u003c V5.5 SP1), SIMOTION D445-2 DP/PN (All versions \u003e= V5.4), SIMOTION D445-2 DP/PN (All versions \u003e= V5.4 \u003c V5.5 SP1), SIMOTION D455-2 DP/PN (All versions \u003e= V5.4 \u003c V5.5 SP1), SIMOTION P320-4 E (All versions \u003e= V5.4), SIMOTION P320-4 S (All versions \u003e= V5.4). When operated with Security Level Low the device does not protect access to certain services relevant for debugging. This could allow an unauthenticated attacker to extract confidential technology object (TO) configuration from the device."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "baseScore": 4.6,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N/E:P/RL:O/RC:C",
                "version": "3.1"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-213",
                  "description": "CWE-213: Exposure of Sensitive Information Due to Incompatible Policies",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2023-06-13T08:17:06.765Z",
            "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
            "shortName": "siemens"
          },
          "references": [
            {
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-482956.pdf"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "assignerShortName": "siemens",
        "cveId": "CVE-2023-27465",
        "datePublished": "2023-06-13T08:17:06.765Z",
        "dateReserved": "2023-03-01T17:29:31.289Z",
        "dateUpdated": "2024-08-02T12:09:43.410Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2017-5689 (GCVE-0-2017-5689)

    Vulnerability from nvd – Published: 2017-05-02 14:00 – Updated: 2025-10-21 23:55
    VLAI CISA KEVIntel
    Summary
    An unprivileged network attacker could gain system privileges to provisioned Intel manageability SKUs: Intel Active Management Technology (AMT) and Intel Standard Manageability (ISM). An unprivileged local attacker could provision manageability features gaining unprivileged network or local system privileges on Intel manageability SKUs: Intel Active Management Technology (AMT), Intel Standard Manageability (ISM), and Intel Small Business Technology (SBT).
    SSVC
    Exploitation: active Automatable: yes Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • Escalation of Privilege
    • CWE-269 - Improper Privilege Management
    Assigner
    Impacted products
    Vendor Product Version
    Intel Corporation Intel Active Mangement Technology, Intel Small Business Technology, Intel Standard Manageability Affected: fixed in versions 6.2.61.3535, 7.1.91.3272, 8.1.71.3608, 9.1.41.3024, 10.0.55.3000, 11.0.25.3001, and 11.6.27.3264 and later
    Create a notification for this product.
    Date Public
    2017-05-01 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-05T15:11:48.401Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.tenable.com/blog/rediscovering-the-intel-amt-vulnerability"
              },
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://downloadmirror.intel.com/26754/eng/INTEL-SA-00075%20Mitigation%20Guide-Rev%201.1.pdf"
              },
              {
                "name": "98269",
                "tags": [
                  "vdb-entry",
                  "x_refsource_BID",
                  "x_transferred"
                ],
                "url": "http://www.securityfocus.com/bid/98269"
              },
              {
                "name": "1038385",
                "tags": [
                  "vdb-entry",
                  "x_refsource_SECTRACK",
                  "x_transferred"
                ],
                "url": "http://www.securitytracker.com/id/1038385"
              },
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://security.netapp.com/advisory/ntap-20170509-0001/"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.embedi.com/files/white-papers/Silent-Bob-is-Silent.pdf"
              },
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://security-center.intel.com/advisory.aspx?intelid=INTEL-SA-00075\u0026languageid=en-fr"
              },
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://h20566.www2.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf03754en_us"
              },
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "http://www.oracle.com/technetwork/security-advisory/cpujul2017-3236622.html"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.embedi.com/news/mythbusters-cve-2017-5689"
              },
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-874235.pdf"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "cvssV3_1": {
                  "attackComplexity": "LOW",
                  "attackVector": "NETWORK",
                  "availabilityImpact": "HIGH",
                  "baseScore": 9.8,
                  "baseSeverity": "CRITICAL",
                  "confidentialityImpact": "HIGH",
                  "integrityImpact": "HIGH",
                  "privilegesRequired": "NONE",
                  "scope": "UNCHANGED",
                  "userInteraction": "NONE",
                  "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                  "version": "3.1"
                }
              },
              {
                "other": {
                  "content": {
                    "id": "CVE-2017-5689",
                    "options": [
                      {
                        "Exploitation": "active"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-02-07T13:43:44.728208Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              },
              {
                "other": {
                  "content": {
                    "dateAdded": "2022-01-28",
                    "reference": "https://www.cisa.gov/known-exploited-vulnerabilities-catalog?field_cve=CVE-2017-5689"
                  },
                  "type": "kev"
                }
              }
            ],
            "problemTypes": [
              {
                "descriptions": [
                  {
                    "cweId": "CWE-269",
                    "description": "CWE-269 Improper Privilege Management",
                    "lang": "en",
                    "type": "CWE"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-10-21T23:55:41.384Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "references": [
              {
                "tags": [
                  "government-resource"
                ],
                "url": "https://www.cisa.gov/known-exploited-vulnerabilities-catalog?field_cve=CVE-2017-5689"
              }
            ],
            "timeline": [
              {
                "lang": "en",
                "time": "2022-01-28T00:00:00.000Z",
                "value": "CVE-2017-5689 added to CISA KEV"
              }
            ],
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "Intel Active Mangement Technology, Intel Small Business Technology, Intel Standard Manageability",
              "vendor": "Intel Corporation",
              "versions": [
                {
                  "status": "affected",
                  "version": "fixed in versions 6.2.61.3535, 7.1.91.3272, 8.1.71.3608, 9.1.41.3024, 10.0.55.3000, 11.0.25.3001, and 11.6.27.3264 and later"
                }
              ]
            }
          ],
          "datePublic": "2017-05-01T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "An unprivileged network attacker could gain system privileges to provisioned Intel manageability SKUs: Intel Active Management Technology (AMT) and Intel Standard Manageability (ISM). An unprivileged local attacker could provision manageability features gaining unprivileged network or local system privileges on Intel manageability SKUs: Intel Active Management Technology (AMT), Intel Standard Manageability (ISM), and Intel Small Business Technology (SBT)."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "Escalation of Privilege",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2020-02-10T14:06:25.000Z",
            "orgId": "6dda929c-bb53-4a77-a76d-48e79601a1ce",
            "shortName": "intel"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.tenable.com/blog/rediscovering-the-intel-amt-vulnerability"
            },
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://downloadmirror.intel.com/26754/eng/INTEL-SA-00075%20Mitigation%20Guide-Rev%201.1.pdf"
            },
            {
              "name": "98269",
              "tags": [
                "vdb-entry",
                "x_refsource_BID"
              ],
              "url": "http://www.securityfocus.com/bid/98269"
            },
            {
              "name": "1038385",
              "tags": [
                "vdb-entry",
                "x_refsource_SECTRACK"
              ],
              "url": "http://www.securitytracker.com/id/1038385"
            },
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://security.netapp.com/advisory/ntap-20170509-0001/"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.embedi.com/files/white-papers/Silent-Bob-is-Silent.pdf"
            },
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://security-center.intel.com/advisory.aspx?intelid=INTEL-SA-00075\u0026languageid=en-fr"
            },
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://h20566.www2.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf03754en_us"
            },
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "http://www.oracle.com/technetwork/security-advisory/cpujul2017-3236622.html"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.embedi.com/news/mythbusters-cve-2017-5689"
            },
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-874235.pdf"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "secure@intel.com",
              "ID": "CVE-2017-5689",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "Intel Active Mangement Technology, Intel Small Business Technology, Intel Standard Manageability",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "fixed in versions 6.2.61.3535, 7.1.91.3272, 8.1.71.3608, 9.1.41.3024, 10.0.55.3000, 11.0.25.3001, and 11.6.27.3264 and later"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "Intel Corporation"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "An unprivileged network attacker could gain system privileges to provisioned Intel manageability SKUs: Intel Active Management Technology (AMT) and Intel Standard Manageability (ISM). An unprivileged local attacker could provision manageability features gaining unprivileged network or local system privileges on Intel manageability SKUs: Intel Active Management Technology (AMT), Intel Standard Manageability (ISM), and Intel Small Business Technology (SBT)."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "Escalation of Privilege"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.tenable.com/blog/rediscovering-the-intel-amt-vulnerability",
                  "refsource": "MISC",
                  "url": "https://www.tenable.com/blog/rediscovering-the-intel-amt-vulnerability"
                },
                {
                  "name": "https://downloadmirror.intel.com/26754/eng/INTEL-SA-00075%20Mitigation%20Guide-Rev%201.1.pdf",
                  "refsource": "CONFIRM",
                  "url": "https://downloadmirror.intel.com/26754/eng/INTEL-SA-00075%20Mitigation%20Guide-Rev%201.1.pdf"
                },
                {
                  "name": "98269",
                  "refsource": "BID",
                  "url": "http://www.securityfocus.com/bid/98269"
                },
                {
                  "name": "1038385",
                  "refsource": "SECTRACK",
                  "url": "http://www.securitytracker.com/id/1038385"
                },
                {
                  "name": "https://security.netapp.com/advisory/ntap-20170509-0001/",
                  "refsource": "CONFIRM",
                  "url": "https://security.netapp.com/advisory/ntap-20170509-0001/"
                },
                {
                  "name": "https://www.embedi.com/files/white-papers/Silent-Bob-is-Silent.pdf",
                  "refsource": "MISC",
                  "url": "https://www.embedi.com/files/white-papers/Silent-Bob-is-Silent.pdf"
                },
                {
                  "name": "https://security-center.intel.com/advisory.aspx?intelid=INTEL-SA-00075\u0026languageid=en-fr",
                  "refsource": "CONFIRM",
                  "url": "https://security-center.intel.com/advisory.aspx?intelid=INTEL-SA-00075\u0026languageid=en-fr"
                },
                {
                  "name": "https://h20566.www2.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf03754en_us",
                  "refsource": "CONFIRM",
                  "url": "https://h20566.www2.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf03754en_us"
                },
                {
                  "name": "http://www.oracle.com/technetwork/security-advisory/cpujul2017-3236622.html",
                  "refsource": "CONFIRM",
                  "url": "http://www.oracle.com/technetwork/security-advisory/cpujul2017-3236622.html"
                },
                {
                  "name": "https://www.embedi.com/news/mythbusters-cve-2017-5689",
                  "refsource": "MISC",
                  "url": "https://www.embedi.com/news/mythbusters-cve-2017-5689"
                },
                {
                  "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-874235.pdf",
                  "refsource": "CONFIRM",
                  "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-874235.pdf"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "6dda929c-bb53-4a77-a76d-48e79601a1ce",
        "assignerShortName": "intel",
        "cveId": "CVE-2017-5689",
        "datePublished": "2017-05-02T14:00:00.000Z",
        "dateReserved": "2017-02-01T00:00:00.000Z",
        "dateUpdated": "2025-10-21T23:55:41.384Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2023-27465 (GCVE-0-2023-27465)

    Vulnerability from cvelistv5 – Published: 2023-06-13 08:17 – Updated: 2024-08-02 12:09
    VLAI
    Summary
    A vulnerability has been identified in SIMOTION C240 (All versions >= V5.4 < V5.5 SP1), SIMOTION C240 PN (All versions >= V5.4 < V5.5 SP1), SIMOTION D410-2 DP (All versions >= V5.4 < V5.5 SP1), SIMOTION D410-2 DP/PN (All versions >= V5.4 < V5.5 SP1), SIMOTION D425-2 DP (All versions >= V5.4 < V5.5 SP1), SIMOTION D425-2 DP/PN (All versions >= V5.4 < V5.5 SP1), SIMOTION D435-2 DP (All versions >= V5.4 < V5.5 SP1), SIMOTION D435-2 DP/PN (All versions >= V5.4 < V5.5 SP1), SIMOTION D445-2 DP/PN (All versions >= V5.4), SIMOTION D445-2 DP/PN (All versions >= V5.4 < V5.5 SP1), SIMOTION D455-2 DP/PN (All versions >= V5.4 < V5.5 SP1), SIMOTION P320-4 E (All versions >= V5.4), SIMOTION P320-4 S (All versions >= V5.4). When operated with Security Level Low the device does not protect access to certain services relevant for debugging. This could allow an unauthenticated attacker to extract confidential technology object (TO) configuration from the device.
    CWE
    • CWE-213 - Exposure of Sensitive Information Due to Incompatible Policies
    Assigner
    Impacted products
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T12:09:43.410Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-482956.pdf"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unknown",
              "product": "SIMOTION C240",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003e= V5.4 \u003c V5.5 SP1"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMOTION C240 PN",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003e= V5.4 \u003c V5.5 SP1"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMOTION D410-2 DP",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003e= V5.4 \u003c V5.5 SP1"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMOTION D410-2 DP/PN",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003e= V5.4 \u003c V5.5 SP1"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMOTION D425-2 DP",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003e= V5.4 \u003c V5.5 SP1"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMOTION D425-2 DP/PN",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003e= V5.4 \u003c V5.5 SP1"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMOTION D435-2 DP",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003e= V5.4 \u003c V5.5 SP1"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMOTION D435-2 DP/PN",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003e= V5.4 \u003c V5.5 SP1"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMOTION D445-2 DP/PN",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003e= V5.4"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMOTION D445-2 DP/PN",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003e= V5.4 \u003c V5.5 SP1"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMOTION D455-2 DP/PN",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003e= V5.4 \u003c V5.5 SP1"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMOTION P320-4 E",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003e= V5.4"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMOTION P320-4 S",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003e= V5.4"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability has been identified in SIMOTION C240 (All versions \u003e= V5.4 \u003c V5.5 SP1), SIMOTION C240 PN (All versions \u003e= V5.4 \u003c V5.5 SP1), SIMOTION D410-2 DP (All versions \u003e= V5.4 \u003c V5.5 SP1), SIMOTION D410-2 DP/PN (All versions \u003e= V5.4 \u003c V5.5 SP1), SIMOTION D425-2 DP (All versions \u003e= V5.4 \u003c V5.5 SP1), SIMOTION D425-2 DP/PN (All versions \u003e= V5.4 \u003c V5.5 SP1), SIMOTION D435-2 DP (All versions \u003e= V5.4 \u003c V5.5 SP1), SIMOTION D435-2 DP/PN (All versions \u003e= V5.4 \u003c V5.5 SP1), SIMOTION D445-2 DP/PN (All versions \u003e= V5.4), SIMOTION D445-2 DP/PN (All versions \u003e= V5.4 \u003c V5.5 SP1), SIMOTION D455-2 DP/PN (All versions \u003e= V5.4 \u003c V5.5 SP1), SIMOTION P320-4 E (All versions \u003e= V5.4), SIMOTION P320-4 S (All versions \u003e= V5.4). When operated with Security Level Low the device does not protect access to certain services relevant for debugging. This could allow an unauthenticated attacker to extract confidential technology object (TO) configuration from the device."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "baseScore": 4.6,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N/E:P/RL:O/RC:C",
                "version": "3.1"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-213",
                  "description": "CWE-213: Exposure of Sensitive Information Due to Incompatible Policies",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2023-06-13T08:17:06.765Z",
            "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
            "shortName": "siemens"
          },
          "references": [
            {
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-482956.pdf"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "assignerShortName": "siemens",
        "cveId": "CVE-2023-27465",
        "datePublished": "2023-06-13T08:17:06.765Z",
        "dateReserved": "2023-03-01T17:29:31.289Z",
        "dateUpdated": "2024-08-02T12:09:43.410Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2017-5689 (GCVE-0-2017-5689)

    Vulnerability from cvelistv5 – Published: 2017-05-02 14:00 – Updated: 2025-10-21 23:55
    VLAI CISA KEVIntel
    Summary
    An unprivileged network attacker could gain system privileges to provisioned Intel manageability SKUs: Intel Active Management Technology (AMT) and Intel Standard Manageability (ISM). An unprivileged local attacker could provision manageability features gaining unprivileged network or local system privileges on Intel manageability SKUs: Intel Active Management Technology (AMT), Intel Standard Manageability (ISM), and Intel Small Business Technology (SBT).
    SSVC
    Exploitation: active Automatable: yes Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • Escalation of Privilege
    • CWE-269 - Improper Privilege Management
    Assigner
    Impacted products
    Vendor Product Version
    Intel Corporation Intel Active Mangement Technology, Intel Small Business Technology, Intel Standard Manageability Affected: fixed in versions 6.2.61.3535, 7.1.91.3272, 8.1.71.3608, 9.1.41.3024, 10.0.55.3000, 11.0.25.3001, and 11.6.27.3264 and later
    Create a notification for this product.
    Date Public
    2017-05-01 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-05T15:11:48.401Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.tenable.com/blog/rediscovering-the-intel-amt-vulnerability"
              },
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://downloadmirror.intel.com/26754/eng/INTEL-SA-00075%20Mitigation%20Guide-Rev%201.1.pdf"
              },
              {
                "name": "98269",
                "tags": [
                  "vdb-entry",
                  "x_refsource_BID",
                  "x_transferred"
                ],
                "url": "http://www.securityfocus.com/bid/98269"
              },
              {
                "name": "1038385",
                "tags": [
                  "vdb-entry",
                  "x_refsource_SECTRACK",
                  "x_transferred"
                ],
                "url": "http://www.securitytracker.com/id/1038385"
              },
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://security.netapp.com/advisory/ntap-20170509-0001/"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.embedi.com/files/white-papers/Silent-Bob-is-Silent.pdf"
              },
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://security-center.intel.com/advisory.aspx?intelid=INTEL-SA-00075\u0026languageid=en-fr"
              },
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://h20566.www2.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf03754en_us"
              },
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "http://www.oracle.com/technetwork/security-advisory/cpujul2017-3236622.html"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.embedi.com/news/mythbusters-cve-2017-5689"
              },
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-874235.pdf"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "cvssV3_1": {
                  "attackComplexity": "LOW",
                  "attackVector": "NETWORK",
                  "availabilityImpact": "HIGH",
                  "baseScore": 9.8,
                  "baseSeverity": "CRITICAL",
                  "confidentialityImpact": "HIGH",
                  "integrityImpact": "HIGH",
                  "privilegesRequired": "NONE",
                  "scope": "UNCHANGED",
                  "userInteraction": "NONE",
                  "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                  "version": "3.1"
                }
              },
              {
                "other": {
                  "content": {
                    "id": "CVE-2017-5689",
                    "options": [
                      {
                        "Exploitation": "active"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-02-07T13:43:44.728208Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              },
              {
                "other": {
                  "content": {
                    "dateAdded": "2022-01-28",
                    "reference": "https://www.cisa.gov/known-exploited-vulnerabilities-catalog?field_cve=CVE-2017-5689"
                  },
                  "type": "kev"
                }
              }
            ],
            "problemTypes": [
              {
                "descriptions": [
                  {
                    "cweId": "CWE-269",
                    "description": "CWE-269 Improper Privilege Management",
                    "lang": "en",
                    "type": "CWE"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-10-21T23:55:41.384Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "references": [
              {
                "tags": [
                  "government-resource"
                ],
                "url": "https://www.cisa.gov/known-exploited-vulnerabilities-catalog?field_cve=CVE-2017-5689"
              }
            ],
            "timeline": [
              {
                "lang": "en",
                "time": "2022-01-28T00:00:00.000Z",
                "value": "CVE-2017-5689 added to CISA KEV"
              }
            ],
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "Intel Active Mangement Technology, Intel Small Business Technology, Intel Standard Manageability",
              "vendor": "Intel Corporation",
              "versions": [
                {
                  "status": "affected",
                  "version": "fixed in versions 6.2.61.3535, 7.1.91.3272, 8.1.71.3608, 9.1.41.3024, 10.0.55.3000, 11.0.25.3001, and 11.6.27.3264 and later"
                }
              ]
            }
          ],
          "datePublic": "2017-05-01T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "An unprivileged network attacker could gain system privileges to provisioned Intel manageability SKUs: Intel Active Management Technology (AMT) and Intel Standard Manageability (ISM). An unprivileged local attacker could provision manageability features gaining unprivileged network or local system privileges on Intel manageability SKUs: Intel Active Management Technology (AMT), Intel Standard Manageability (ISM), and Intel Small Business Technology (SBT)."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "Escalation of Privilege",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2020-02-10T14:06:25.000Z",
            "orgId": "6dda929c-bb53-4a77-a76d-48e79601a1ce",
            "shortName": "intel"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.tenable.com/blog/rediscovering-the-intel-amt-vulnerability"
            },
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://downloadmirror.intel.com/26754/eng/INTEL-SA-00075%20Mitigation%20Guide-Rev%201.1.pdf"
            },
            {
              "name": "98269",
              "tags": [
                "vdb-entry",
                "x_refsource_BID"
              ],
              "url": "http://www.securityfocus.com/bid/98269"
            },
            {
              "name": "1038385",
              "tags": [
                "vdb-entry",
                "x_refsource_SECTRACK"
              ],
              "url": "http://www.securitytracker.com/id/1038385"
            },
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://security.netapp.com/advisory/ntap-20170509-0001/"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.embedi.com/files/white-papers/Silent-Bob-is-Silent.pdf"
            },
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://security-center.intel.com/advisory.aspx?intelid=INTEL-SA-00075\u0026languageid=en-fr"
            },
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://h20566.www2.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf03754en_us"
            },
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "http://www.oracle.com/technetwork/security-advisory/cpujul2017-3236622.html"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.embedi.com/news/mythbusters-cve-2017-5689"
            },
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-874235.pdf"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "secure@intel.com",
              "ID": "CVE-2017-5689",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "Intel Active Mangement Technology, Intel Small Business Technology, Intel Standard Manageability",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "fixed in versions 6.2.61.3535, 7.1.91.3272, 8.1.71.3608, 9.1.41.3024, 10.0.55.3000, 11.0.25.3001, and 11.6.27.3264 and later"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "Intel Corporation"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "An unprivileged network attacker could gain system privileges to provisioned Intel manageability SKUs: Intel Active Management Technology (AMT) and Intel Standard Manageability (ISM). An unprivileged local attacker could provision manageability features gaining unprivileged network or local system privileges on Intel manageability SKUs: Intel Active Management Technology (AMT), Intel Standard Manageability (ISM), and Intel Small Business Technology (SBT)."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "Escalation of Privilege"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.tenable.com/blog/rediscovering-the-intel-amt-vulnerability",
                  "refsource": "MISC",
                  "url": "https://www.tenable.com/blog/rediscovering-the-intel-amt-vulnerability"
                },
                {
                  "name": "https://downloadmirror.intel.com/26754/eng/INTEL-SA-00075%20Mitigation%20Guide-Rev%201.1.pdf",
                  "refsource": "CONFIRM",
                  "url": "https://downloadmirror.intel.com/26754/eng/INTEL-SA-00075%20Mitigation%20Guide-Rev%201.1.pdf"
                },
                {
                  "name": "98269",
                  "refsource": "BID",
                  "url": "http://www.securityfocus.com/bid/98269"
                },
                {
                  "name": "1038385",
                  "refsource": "SECTRACK",
                  "url": "http://www.securitytracker.com/id/1038385"
                },
                {
                  "name": "https://security.netapp.com/advisory/ntap-20170509-0001/",
                  "refsource": "CONFIRM",
                  "url": "https://security.netapp.com/advisory/ntap-20170509-0001/"
                },
                {
                  "name": "https://www.embedi.com/files/white-papers/Silent-Bob-is-Silent.pdf",
                  "refsource": "MISC",
                  "url": "https://www.embedi.com/files/white-papers/Silent-Bob-is-Silent.pdf"
                },
                {
                  "name": "https://security-center.intel.com/advisory.aspx?intelid=INTEL-SA-00075\u0026languageid=en-fr",
                  "refsource": "CONFIRM",
                  "url": "https://security-center.intel.com/advisory.aspx?intelid=INTEL-SA-00075\u0026languageid=en-fr"
                },
                {
                  "name": "https://h20566.www2.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf03754en_us",
                  "refsource": "CONFIRM",
                  "url": "https://h20566.www2.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf03754en_us"
                },
                {
                  "name": "http://www.oracle.com/technetwork/security-advisory/cpujul2017-3236622.html",
                  "refsource": "CONFIRM",
                  "url": "http://www.oracle.com/technetwork/security-advisory/cpujul2017-3236622.html"
                },
                {
                  "name": "https://www.embedi.com/news/mythbusters-cve-2017-5689",
                  "refsource": "MISC",
                  "url": "https://www.embedi.com/news/mythbusters-cve-2017-5689"
                },
                {
                  "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-874235.pdf",
                  "refsource": "CONFIRM",
                  "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-874235.pdf"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "6dda929c-bb53-4a77-a76d-48e79601a1ce",
        "assignerShortName": "intel",
        "cveId": "CVE-2017-5689",
        "datePublished": "2017-05-02T14:00:00.000Z",
        "dateReserved": "2017-02-01T00:00:00.000Z",
        "dateUpdated": "2025-10-21T23:55:41.384Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }